Upload
volien
View
224
Download
0
Embed Size (px)
Citation preview
GEMS Navigation Limited Address:Room301,HuaChuangDaBuilding,CuizhuRd,46District,Bao’an,Shenzhen,China. Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected]
Document Number 120230 Rev 001 2016-08-31 Page 1 / 12
iGS18 GPS/GNSS Splitter
Intelligent Port Control: Control through DC or blocking DC; Intelligent port monitoring: Voltage monitor port;
Connecting the PC via the serial port; Used in automatic multi‐port status test;
Gain : 0dB~10dB;
Response For GPS:L1,L2,L2C,L5;
Glonass:G1,G2;
Galileo:L1,E1,E2,E5(E5a,E5b),E6;
Beidou2:B1,B2,B3;
IRNSS:L1,L5;
OmniStar
High Isolations >28dB
www.gemsrf.cn
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 2 / 12
Description
The iGS18 GPS Splitter is a one‐input, eight‐output GPS device. This product typically finds application where an input from an active GPS roof antenna is split evenly between four receiving GPS units. In this scenario, the iGS18 can be configured to pass DC from an RF output to the antenna input port in order to power an active GPS antenna on that port. The others outputs would feature a 200 Ohm DC load to simulate an antenna DC current draw for any receiver connected to those ports. Individual iGS18 work independently as a separate product.iGS18 can control the 8 output ports power state, can detect the output port voltage.
Specifications Electrical Specifications, Operating Temperature ‐40 to 85℃.
Parameter Conditions Min Typ Max Units
Freq. Range Ant – Any Port 1.1 1.7 GHz
In &Out Imped. In, all output ports 50 Ω
Gain 0dB
In- Output ports, ,Unused Ports ‐ 50Ω -1 0 1
dB Amplified(10dB) 9 10 11
Input SWR All Ports 50Ω 2.0:1 -
Output SWR All Ports 50Ω 2.0:1 -
Nois Figure- Amplified Ant‐ Any Port, Unused Ports‐50Ω 2.2 dB
Gain Flatness (Amplified)
|L1‐L2|,Ant‐ Any Port, Unused Ports‐50Ω 3 dB
Amp. Balance |J1‐J2|, Ant‐ Any Port, Unused Ports‐50Ω 0.5 dB
Phase Balance Phase(J1‐J2), Ant‐ Any Port, Unused
Ports‐50Ω 1.0 deg
Group Delay Flatness 1 ns
Isolation
Amplified
Adjacent Ports: In ‐ 50Ω 28
dB Opposite Ports: In – 50Ω 34
Gain:10dB Adjacent Ports: In ‐ 50Ω 28
Opposite Ports: In ‐ 50Ω 34
AC IN Wall Mount transformer 230 VAC
DC IN
DC Block, All ports with a 200Ω Load 14
VDC PASS DC, Amplified 3 16
PASS DC, Passive 16
Powered, to be specified
Device Current 16 mA
Current
Pass DC, No Powered configuration, DC input on J1
250 mA
Powered, to be specified mA
Max RF Input (Amplified)
Max RF input without damage 0 dBm
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 3 / 12
Performance Data
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 4 / 12
Operation instructions
1. Connect serial port
Pin definition: 1 +12V; 2 GND; 3 RXD; 4 +12V; 5 GND; 6 TXD; Note: RXD product iGS18 serial port connector TXD; product TXD connected to the serial port connector RXD. 2. Serial port parameters Open serial debug assistant software
iGS18
1 2 3 4 5 6
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 5 / 12
Press table setting parameters:
Set items Default parameter Baud Rate 9600 Check bit nothing Data bits 8 Stop bit 1
Pin definition
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 6 / 12
Check the display of the receiving time, the sixteen band display, according to the sixteen system to send. Serial number view: Right‐click on "My Computer", select "Manage" Double‐click "Device Manager" and double‐click can see the connection port serial number is COM4. NOTE: You must insert the serial connector can see the serial number.
Connect the power to iGS18 can start off through the control port and a read port voltage (such as the output port and do not have electricity, port external power supply voltage can be read port).
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 7 / 12
(3) Calculation of power off and read voltage instructions Instruction consists of 8 hexadecimal format.
DLE STX CMD Parameter DLE ETX BCCH BCCL STX: 0x02 frame start flag; DLE: 0x10 transcoding, for use in the frame start or frame end flag before, if DLE equal to the value data appears in the frame, the data retransmission protocol requires one to represent distinction, that is represented by two consecutive DLE data, a DLE represents the transcoding; CMD: Communication instruction data type, including data communication instruction (0xF1) and control commands (0xF2) of two types; Parameter: CMD communication instruction data content, data length; ETX: 0x03 frame terminator flag (not included in the back of the validation data); BCCL: binary BCC check code low 8; BCCH: binary BCC code high 8. Then DLE, STX and ETX three hexadecimal constant, which is the first 1,2,5,6 These four numbers are the same, you need to calculate the CMD, parameters, BCCH and BCCL four hexadecimal number. Example: Let the second output port powered iGS18 remaining output port is not energized. (1) CMD calculation
Then determine the output port status instruction type instruction, CMD is the third number is 0xF2 ("0x" indicates a hexadecimal number).
(2) Parameter calculation (fourth number) This is the CMD communication command data content, calculation method: 2‐port powered remaining ports are not powered by the binary representation of 11,111,101 from the back followed by representatives of eight ports (1 port is the penultimate one) "1" indicates that no power "0" is energized, to be converted to hexadecimal "FD". (You can use the computer comes with the calculator, open the calculator click "view" select "programmers"). For binary input 1111 1101, converted to hexadecimal, then get the "parameters" calculation results, followed by analogy, if we want to make 4 port energized other energized so obtained for binary number 1111 0111, converted to hexadecimal "F7", then push to make 4, 6, 7 energized the remaining energized by binary number 1001 0111 conversion into hexadecimal number is "97".
(3) BCCH、BCCL Calculation
BCCH calculation: The CMD, parameters, DLE, STX four hexadecimal numbers and give the hexadecimal number penultimate position, if less than or equal to 9 then use that number plus 30, if more than 9 then use that number plus 37 to give BCCH; BCCL calculation: The CMD, parameters, DLE, STX four hexadecimal numbers and give the hexadecimal number of the penultimate one, if less than or equal to 9 then use that number plus 30, if more than 9 then use that number plus 37 to give BCCL.
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 8 / 12
Example: above the 2 port on the power of the "parameters" for 0xFD, then 0xF2+0xFD+0x10+0x03=0x202 0x202 countdown second is less than 0 less than 9 plus 0x30 is equal to 0x30 to get BCCH; 0x202 countdown to the first 2 less than 9 so plus 0x30 is equal to 0x32 get BCCL; Finally, to give 2 outputs energize the entire rest of the control command is not energized 10 02 F2 FD 10 03 30 32. Example: Let 4, 6, 7 serial energized energized not get to rest "argument" is 0x97, then 0xF2+ 0x97 + 0x10 + 0x03 =0x19C 0x19C countdown second equal to 9 equal to 9 plus 0x30 equal to 0x39 to get BCCH; 0x19C countdown to the first C (for decimal to 12) is greater than 9 plus 0x37 equals 0x43 to get BCCL; Finally, to give 4, 6, 7 port energized not energized the rest of the entire instruction is 10 02 F2 97 10 03 39 43.
Voltage command query: Judging instruction for voltage inquiry command, so the CMD 0xF1.
Don't set port on‐off so "parameters" does not need to compute the write, and then calculating the BCCH and BCCL, because voltage inquiry command is a fixed instruction so BCCH and BCCL also is only a fixed number of BCCH:0x30; BCCL:0x34, can be calculated 0Xf1+0x10+0x03=0x104, BCCH=0+30=30; BCCL=4+30=34. Finally get the voltage for the entire instruction inquiry 10 02 F1 10 03 30 34.
Now Demo output port 2 is energized the remaining ports is not energized, then the detection port voltage: Connection serial line and connect the power supply, open serial port assistant set parameters and uncheck show reception time, hexadecimal display, press to send the hex and click open the serial port, enter the above calculation 2 output port through electrical command click send, can see the serial number according to will receive feedback data proves the design success, now input voltage inquiry command, serial data reception will feedback is the port voltage values to hexadecimal form said and need to convert to decimal. Example:
Numerical see the port 2 is 0x1395 converted to decimal 5013mv energized state, the remaining ports have 0x0009,0x0004,0x0000, respectively 9mv, 4mv, 0mv is not energized.
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 9 / 12
Example: 2 output port through the rest of the electricity.
Port through power calculation instruction schematic
DLE STX
F1 for query port voltage F2 for port power setup
Energization represents 1111 1101 2‐port powered, “0” is energized, “1” is not energized, convert hex to 0xFD. Binary number from the back follower by the corresponding port 1‐8 (The penultimate one corresponding to 1 port)
DLE ETX
BCCH: 0xF2+0xFD+0x10+0x03=0x202The last one is 2<9, 2+30=32; The countdown to the first if less than or equal to 9 plus 30, if more than 9 plus 37
BCCH:0xF2+0xFD+0x10+0x03=0x202The last second bits are 0<9,0+30=30; The reciprocal second if less than or equal to 9 plus 30, if more than 9 plus 37
10 02 F2 FD 10 03 30 32
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 10 / 12
Basic power off instruction:
Energized state Corresponding instruction Output is not electricity 10 02 F2 FF 10 03 30 34 1 port through the rest of the electricity 10 02 F2 FE 10 03 30 33 2 port through the rest of the electricity 10 02 F2 FD 10 03 30 32 3 port through the rest of the electricity 10 02 F2 FB 10 03 30 30 4 port through the rest of the electricity 10 02 F2 F7 10 03 46 43 5 port through the rest of the electricity 10 02 F2 EF 10 03 46 34 6 port through the rest of the electricity 10 02 F2 DF 10 03 45 34 7 port through the rest of the electricity 10 02 F2 BF 10 03 43 34 8 port through the rest of the electricity 10 02 F2 7F 10 03 38 34 All energized output 10 02 F2 00 10 03 30 35
Schematic diagram of serial connection:
IN
2 1 iGS18
4 3
6 5 8 7 1 2 3 4 5 6
+12V GND RX +12V GND TX
Power
+12V
Serial port
connector
GND
Serial port
connector
TX
Power
+12V
Power
‐12V
Serial port
connector
RX
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 11 / 12
Order Informations And Available Options
Please contact us for more configurations and application supports. Email: [email protected].
Part Number: Standard: 0Db gain, N Female In &Out, Pass DC IN&J1
iGS18
Gain Options: Blank (Standard)‐0dB ‐Axx xx=01‐31, Desired Gain Level ‐A Active, 10dB gain ‐P Passive
A
Connectors In Blank (Standard)‐N Female ‐NF N Female ‐NM N Male; ‐SF SMA Female ‐SM SMA Male; ‐TF TNC Female ‐TM TNC Male; ‐BF BNC Female ‐BM BNC Male
DC NM
Pass DC or Block DC Options: Blank (Standard)‐ Pass DC In&J1 BI‐Pass DC on J1 and Block DC In B‐Block DC Out and In
BO
Power Options: Blank (Standard)‐Without Power adapter ‐DC With 230/5V Power adapter
Tel: +86-755-29644311 Fax: +86-755-29644383 Email: [email protected] Web: www.gemsrf.cn Document Number 120230 Rev 001 2016-08-31 Page 12 / 12
Mechanical
Frequency reference table:
Gllobal/Compass Navigation Satellite Systems(GNSS/CNSS)Frequency (MHz)
1164 1176
1188 1192 1207
1215
1219 1227
1239
1245 1252
1259
1266 1268 1278
1290
1535
1540 1545
1550
1558
1558 1561
1563 1575
1587
1592
1602 1609
1616 2491
GPS(USA) L1,L2,L2C,L5 Glonass(Russia) G1,G2
Galileo(Europian) E5+/-15L1,E1,E2,E5(E5a,E5b),E6 E5a+/-12 E5b+/-12Compass (Beidou 2,China) B3+/-10Beidou 1
(China,Tx(LHCP)/Rx(RHCP)IRNSS (India) L5+/-15 S+/-15OmniStar
L5+/-12 G1+/-7
O+/-14---->
E2 L1+/-17 E1
B1+/-2
L1+/-12
L1+/-12L6+/-5L2/L2C+/-12
B2+/-10
G2+/-7
E6+/-12 L6+/-5
L S