Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
Albany Plus™116
DECORATIVE www.mkelectric.co.uk
Available in both matt chrome and satin brass finishesProviding a range of products that complement the décor of the finest modern andtraditional interiors
Pre-treated, heat-cured powder lacquer finishEnsures that the range is durable, tarnish resistant and maintains its stylish andunderstated appearance for many years and eliminates the need for a gasket
Total safetyUnique 3-pin operated “child resistant shutter system”, which is designed to inhibit accessto the electricity supply, unless all 3 pins of a standard British 13 Amp plug are in position
Comprehensive range of sockets, switches and ancillary productsWhatever the application, the Albany Plus range has a wiring device to suit
Available in both matt chrome and satin brass finishes, Albany Plus brings stylish yet robust good
looks to both contemporary and classical interiors. Manufactured from the finest materials and coated
with a special heat-cured powder lacquer finish ensures that these accessories maintain their
discerning appearance for years to come.
In addition to good looks, with Albany Plus comes unrivalled safety. Utilising MK’s unique 3-pin
operated safety shutter, that prevents misuse and unsafe access to live circuitry, Albany Plus offers the
user the peace of mind and comfort that they have the safest range of wiring devices available
installed in their surroundings.
117Albany Plus
TECHNICAL HOTLINE +44 (0)1268 563720 DECORATIVE
Terminal screws are backed out
and captive. Terminals are upwards
facing to make installation easier.
Funnel entrance to terminals.
Clear terminal markings for easy
identification.
Satin Brass finish has subtle good looks
to suit classic interiors.
Stylish Satin Chrome finish compliments
modern interior design.
13 AMP SOCKET AVAILABLE
WITH NEON INDICATORS
STYLISH CURVED DESIGN
WITH WHITE INSERTS
Blends unobtrusively into
the environment
UNIQUE 3-PIN “CHILD RESISTANT
SHUTTER SYSTEM”
Designed to inhibit access to the
electricity supply, unless all 3 pins
of a standard British 13 Amp plug
are in position
DOUBLE POLE SWITCHING
PRE-TREATED HEAT-CURED
POWDER LACQUER FINISH
Ensures that the range is
durable and tarnish resistant
and eliminates the
requirement for a gasket
MATCHING
SCREWS
Albany Plus118
DECORATIVE www.mkelectric.co.uk
SwitchsocketOutlets
13 AMP
FLUSH
WITH OUTBOARD
ROCKERS
13 AMP
FLUSH
NON STANDARD
13 AMP
FLUSH
FILTERED
13 AMP
FLUSH
MOUNTING BOXESFLUSH 25mm1 GANG: 861 ZIC2 GANG: 862 ZICFLUSH 35mm (for extra wiring space)1 GANG: 866 ZIC2 GANG: 886 ZICSURFACE WITH KNOCKOUTS1 GANG: K899 ALM2 GANG: K897 ALMSURFACE WITHOUT KNOCKOUTS1 GANG: K829 ALM2 GANG: K830 ALMDIMENSIONS:1 GANG: 86 x 86mm 2 GANG: 86 x 146mmFIXING CENTRES:1 GANG: 60.3mm 2 GANG: 120.6mmBS.1363 Pt. 2: 1995
K2958 MCOK2958 SAB1 GANG DP DUAL EARTH TERMINALS
K2958D6MCO1 GANG DP WITH RED ROCKERDUAL EARTH TERMINALS
K2948 MCOK2948 SAB2 GANG DP
K2948D6MCO2 GANG DP WITH RED ROCKERS
5
5
10
10
10
10
High Integrity EarthingK2958, K2458, K2947Fitted with two earth terminals to provide a double earth facility for usewhen installations are to comply withSection 607 of BS.7671, IEE WiringRegulations
Double pole switchingAll switchsockets have double poleswitching (neutral makes first, breakslast).
K2458 MCOK2458 SAB1 GANG DPDUAL EARTH TERMINALSWITH NEON
K2448 MCOK2448 SAB2 GANG DPWITH NEONS
5
5
10
10 K2947 MCOK2947 SAB2 GANG DPWITH OUTBOARD ROCKERS AND DUAL EARTH TERMINALS
K2947D6MCO2 GANG DPWITH OUTBOARD RED ROCKERS AND DUAL EARTH TERMINALS
K2947CEMCOK2947CESAB2 GANG DPWITH OUTBOARD ROCKERS AND ‘CLEAN EARTH’ FACILITY
5
5
5
5
5
K1258, K1259, These products are providedwith facilities for ‘clean earth’connection and are suitable fornon standard plugs with ‘T’shaped earth pin. See page170.
BS.1363 Pt.2: 1995where relevant
K1258 MCOK1258 SAB1 GANG DP WITHCLEAN EARTH FACILITY
K1259 MCOK1259 SAB 2 GANG DP WITHCLEAN EARTH FACILITY
K1259D6MCO2 GANG DPWITH RED ROCKERS ANDCLEAN EARTH FACILITY
1
1
1
1
5
MOUNTING BOX866 ZIC
Provides two way filtering toreduce voltage spikes and radiofrequency interference.Protected by thermal cut out.Fitted with two earth terminals toprovide a double earth facility foruse when installations are tocomply with Section 607 ofBS.7671, IEE Wiring Regulations
Maximum total load 13 ampsDIMENSIONS: 86 x 146 x 39mmFIXING CENTRES: 120.6mmBS.5733: 1995
K2826 MCO2 GANG DP SPIKE AND RFI
K1800 WHIREPLACEMENT FILTER SOCKET
5
1
K2458 MCO
K2458 SAB
K2448 MCO
K1258 MCOK2958 MCO
K2958 SAB
K2948 MCO
K2948 SAB
K2947 D6 MCO
K1258 SAB
K1259 MCO
K1259 SABK2947 CE SAB
K2947 MCO
K2947 SAB
K2448 SAB
K2826 MCO
K2947 CE MCOK2947 CE SAB This product is provided withfacilities for ‘clean earth’connection.BS.1363 Pt.2: 1995where relevant
K1800 WHI
(NON UK)
16 AMP
MODULAR FORMAT
FLUSH
MOUNTING BOXES: FLUSH 35mm
(2P+E SOCKETS)1 GANG: 866 ZIC 2 GANG: 886 ZIC*
SURFACE WITH KNOCKOUTS: 1 GANG: K899 ALM 2 GANG: K897 ALM*
WITHOUT KNOCKOUTS:1 GANG: K829 ALM 2 GANG: K830 ALM*
DIMENSIONS: 1 GANG: 86 x 86mm 2 GANG: 86 x 146mm*The universal socket does not incorporatean earth contact. Therefore, appliancesneeding earth connection (class 1equipment) must NOT be used with thissocket. The socket is intended for use withBS, USA and CEE standard plugs.DIMENSIONS: 1 GANG: 86 x 86mmIEC 60884-1: 2002BS.5733:1995 (Universal)* German type only
K182 MCO or K182 SABwith K5831 WHI1 GANG 16 AMP 250V SHUTTERED GERMAN TYPE (2P+E) SOCKET
K184 MCO or K184 SABwith 2 x K58312 GANG 16 AMP 250V SHUTTERED GERMAN TYPE (2P+E) SOCKETSK3431 MCO or K3431 SABwith K4901 WHI & K37011 GANG 16 AMP 125/250VSHUTTERED UNIVERSAL TYPE SOCKET
1010
101
101
SwitchsocketOutlets
RCD PROTECTED
13 AMP
FLUSH
ROUND PIN
FLUSH
Socket Outlets
13 AMP
FLUSH
15 AMP
127V
FLUSH
K6101 MCOK6101 SAB1 GANG10mA RATED TRIPPING CURRENTACTIVE CONTROL CIRCUIT
K6301 MCOK6301 SAB1 GANG 30mA RATED TRIPPING CURRENTACTIVE CONTROL CIRCUIT
K6304 MCOK6304 SAB1 GANG 30mA RATED TRIPPING CURRENTPASSIVE CONTROL CIRCUIT
11
11
11
MOUNTING BOXESFLUSH 25mm: 861 ZICFLUSH 35mm: (for extra wiringspace) 866 ZICSURFACE WITH KNOCKOUTS: K899 ALMWITHOUT KNOCKOUTS: K829 ALMDIMENSIONS: 86 x 86mmFIXING CENTRES: 60.3mm BS.546: 1950
K2881 MCOK2881 SAB1 GANG DP5 AMPSHUTTERED
K2883 MCOK2883 SAB1 GANG DP15 AMPSHUTTERED
55
55
MOUNTING BOXESFLUSH 25mm1 GANG: 861 ZIC2 GANG: 862 ZICFLUSH 35mm (for extra wiring space)1 GANG: 866 ZIC2 GANG: 886 ZICSURFACE WITH KNOCKOUTS:1 GANG: K899 ALM2 GANG: K897 ALMWITHOUT KNOCKOUTS:1 GANG: K829 ALM2 GANG: K830 ALMDIMENSIONS:1 GANG: 86 x 86mm 2 GANG: 86 x 146mmFIXING CENTRES:1 GANG: 60.3mm 2 GANG: 120.6mmBS.1363: Pt 2: 1995
K732 MCOK732 SAB1 GANG
K733 MCOK733 SAB2 GANG WITH DUAL EARTH TERMINALS
55
55
MOUNTING BOXESFLUSH 25mm1 GANG: 861 ZIC2 GANG: 862 ZICFLUSH 35mm (for extra wiring space)1 GANG: 866 ZIC2 GANG: 886 ZICSURFACE WITH KNOCKOUTS:1 GANG: K899 ALM2 GANG: K897 ALMWITHOUT KNOCKOUTS:1 GANG: K829 ALM2 GANG: K830 ALMDIMENSIONS:1 GANG: 86 x 86mm 2 GANG: 86 x 146mmFIXING CENTRES:1 GANG: 60.3mm 2 GANG: 120.6mmSSA 444:1985
K2261 MCOK2261 SAB1 GANG SHUTTERED
K2262 MCOK2262 SAB2 GANG SHUTTERED
11
11
K2881 MCO
K2881 SAB
K732 MCO K2261 MCOK6101 MCO
K6301 MCO
K6301 SAB
K2883 MCO
K2883 SAB
K732 SAB
K733 MCO
K733 SAB
K2261 SAB
K2262 MCO
K2262 SABK6304 MCO
High Integrity EarthingK733 is provided with dual earthterminals for use when installationsare to comply with Section 607 ofBS.7671, IEE Wiring Regulations
K182 MCO / K5381 WHI
K182 SAB / K5381 WHI
K3431 MCO / K4901 WHI
K3431 SAB / K4901 WHI
119Albany Plus
TECHNICAL HOTLINE +44 (0)1268 563720 DECORATIVE
MOUNTING BOXESFLUSH: 886 ZICBoxes must have a minimum depth of35mmSURFACE WITH KNOCKOUTS: K897 ALMWITHOUT KNOCKOUTS: K830 ALMEarth pin operated shutter.It is important to ensure that thecorrect control circuit, active or passive,is selected for each application, seepage 229 for definitions.These products are pulsating d.c. anda.c. fault current sensitive.Only suitable for supply voltage of240V a.c., 50Hz.DIMENSIONS: 86 x 146mmFIXING CENTRES: 120.6mmBS.7288: 1990
Albany Plus120
DECORATIVE www.mkelectric.co.uk
Non StandardSocket Outlets
13 AMP
FLUSH
Connection Units
SWITCHED
FUSED
FLUSH
MOUNTING BOXESFLUSH 25mm: 862 ZICFLUSH 35mm: 886 ZIC(for extra wiring space)SURFACE (MCO) : WITH KNOCKOUTS: K897 ALM WITHOUT KNOCKOUTS: K830 ALMK1239/749These products are providedwith facilities for ‘clean earth’connections and are suitablefor non-standard plugs with ‘T’shaped earth pins.
For compatible non standardplugs see page 170.
DIMENSIONS: 86 x 146mmFIXING CENTRES: 120.6mmBS.1363 Pt. 2: 1995 where relevant
K1239 MCOK1239 SAB2 GANG WITHCLEAN EARTH FACILITY
5
5
MOUNTING BOXES
FLUSH: 866 ZIC
SURFACE (MCO) WITH KNOCKOUTS:K899 ALMWITHOUT KNOCKOUTS:K829 ALMAll connection units arefitted with a 13amp fuse (toBS1362)TERMINAL CAPACITY2 x 6mm2 stranded (max)
DIMENSIONS:86 x 86mm
FIXING CENTRES:60.3mm
BS. 1363 Pt 4: 1995
K931 MCOK931 SAB DP SWITCHED WITH FLEX OUTLET
K941 MCOK941 SAB DP SWITCHED
K941KOMCODP SWITCHED WITH TAMPERPROOF FUSE CARRIER SCREW
1
1
10
5
5 K961 MCOK961 SAB DP SWITCHED WITH NEON
K961KOSABDP SWITCHED WITH TAMPERPROOF FUSE CARRIER SCREW
K961D6MCODP SWITCHED WITH NEON AND RED ROCKER
K971 MCOK971 SABDP SWITCHED WITH FLEX OUTLET ANDNEON
5
5
1
1
1
10 K971D6MCODP SWITCHED WITH FLEX OUTLET, NEON AND RED ROCKER
K971KOMCODP SWITCHED WITH FLEX OUTLET,NEON AND TAMPERPROOFFUSE CARRIER SCREW
K973KOMCODP WITH SECRET KEY OPERATED SWITCH, NEON AND TAMPERPROOF FUSE CARRIER SCREW
1
1
1
Floor Mounted Socket Outlets
13 AMP
MOUNTING BOXESFLUSH: 1 GANG: 866 ZIC2 GANG: 886 ZICBoxes must have a minimumdepth of 35mmRotary operated shutter.DIMENSIONS:1 GANG: 102 x 86mm 2 GANG: 102 x 146mmFIXING CENTRES:1 GANG: 60.3mm 2 GANG: 120.6mmBS.1363: Pt 2: 1995
740 MCO740 SAB1 GANG SWITCHSOCKET WITH SPRING LOADED HINGED COVER PLATE
741 MCO741 SAB1 GANG SOCKET WITH SPRING LOADED HINGED COVER PLATE
742 MCO742 SAB2 GANG SOCKET WITH SPRING LOADED HINGED COVER PLATE
749 MCO1 GANG NON STANDARDSOCKET WITH SPRINGLOADEDHINGED COVER PLATE
10
11
1010
1010
741 MCO
741 SAB
750 MCO750 SABFLOOR MOUNTED 15A 127VSOCKET WITH SPRINGLOADED HINGED COVERPLATE
1010
750 MCO
750 SAB
K941 MCO
K941 SAB
K961 MCO
K1239 MCO
K1239 SAB
K971 D6 MCOK961 SAB
K961 D6 MCO K971 KO MCO
K971 MCO K973 KO MCO
K971 SAB
K931 MCO
15 AMP
NON UK
MOUNTING BOXESFLUSH 25mm1 GANG: 861 ZICFLUSH 35mm (for extra wiringspace)1 GANG: 866 ZICSURFACE WITH KNOCKOUTS:1 GANG: K899 ALMWITHOUT KNOCKOUTS:1 GANG: K829 ALMDIMENSIONS:1 GANG: 86 x 86mm FIXING CENTRES:1 GANG: 60.3mmSSA 444:1985
ConnectionUnits
UNSWITCHED
FUSED
FLUSH
DP Switches
20 AMP
FLUSH
32 AMP
FLUSH
45 AMP
FLUSH
MOUNTING BOXES
FLUSH: 866 ZIC
SURFACE (MCO) : WITH KNOCKOUTS:K899 ALMWITHOUT KNOCKOUTS:K829 ALMAll connection units arefitted with a 13amp fuse (toBS1362)
TERMINAL CAPACITY2 x 6mm2 stranded (max)
DIMENSIONS: 86 x 86mm
FIXING CENTRES: 60.3mm
BS. 1363 Pt 4: 1995
K948 MCOK948 SAB
K948KOMCOWITH TAMPERPROOF FUSE CARRIER SCREW
K958 MCOWITH NEON
K978 MCOK978 SAB WITH FLEX OUTLET AND NEON
1
5
1
1
1
5
MOUNTING BOXES
FLUSH: 866 ZIC
SURFACE (MCO) WITH KNOCKOUTS:K899 ALMWITHOUT KNOCKOUTS:K829 ALMTERMINAL CAPACITY2 x 6mm2 stranded (max)
DIMENSIONS:86 x 86mm
FIXING CENTRES:60.3mm
BS EN 60669-1: 2000
K5213 MCO
K5233 MCOK5233 SAB WITH NEON
1
1
1 K5233D6MCOWITH NEON AND RED ROCKER
K5250 MCOK5250 SAB WITH FLEX OUTLET AND NEON
1
1
1
MOUNTING BOXES
FLUSH:866 ZIC (6mm2 conductors)877 ZIC (10mm2 conductors)
SURFACE (MCO) :
WITH KNOCKOUTS:K899 ALM
WITHOUT KNOCKOUTS:K829 ALM
DIMENSIONS: 86 x 86mm
FIXING CENTRES: 60.3mm
BS EN 60669-1: 2000
K5106 MCOK5106 SAB WITH NEON
1
1
MOUNTING BOXES
FLUSH:886 ZIC (6mm2 conductors)878 ZIC (10mm2 conductors)
SURFACE (MCO)
WITH KNOCKOUTSK897 ALM
WITHOUT KNOCKOUTSK830 ALM
DIMENSIONS: 86 x 146mm
FIXING CENTRES: 120.6mm
BS.3676 Pt.1: 1989
K5236 MCOK5236 SAB WITH NEON
1
1
CookerSwitches
K948 MCO
K948 SAB
K958 MCO
K978 SAB
K5233 MCO
K5233 SAB
K5250 MCO
K5106 MCO
K5250 SAB
K5106 SAB
K5236 MCO
K5236 SAB
K5261 MCO
K5261 SAB
K5213 MCO K5233 D6 MCO
DP Switches are notrecommended forswitching large banksof PCs
K5261 MCOK5261 SAB 1
1
45 AMP DP MAIN SWITCHAND 13 AMPSWITCH SOCKETOUTLET WITHNEONS
MOUNTING BOXES
FLUSH: 886 ZIC (Up to 6mm2 conductor)878 ZIC (Up to 10mm2 conductor)
Rotary operated shutter.
DIMENSIONS: 86 x 146mm
FIXING CENTRES: 120.6mm
BS.4177: 1992
121Albany Plus
TECHNICAL HOTLINE +44 (0)1268 563720 DECORATIVE
Albany Plus122
DECORATIVE www.mkelectric.co.uk
Triple Pole &NeutralSwitch
32 AMP
FLUSH
Shaver SupplyUnits
FLUSH
Flex Outlets(NON UK)
FLUSH
Plateswitches
10 AMP
FLUSH
10 AMP
WIDE ROCKER
FLUSH
MOUNTING BOX
FLUSH: 878 ZIC
This product is rated at 440volts with a motor load ratingof up to 12kW - 16 HP at415V 3 phase.
It has a utilisation category ofAC22A– switching of mixedresistive and inductive loadsincluding moderate overloadsfor a continuous duty of 32amps. Making capacity is2000 amps peak.
TERMINAL CAPACITY: 16mm2 conductors.
DIMENSIONS: 146 x 86mm
BS EN 60947-3: 1992
K5114 MCOWITH NEON
1
MOUNTING BOXESFLUSH: 878 ZIC
This design incorporates a doublewound isolating transformer rated20VA at 230 or 115 volts andmeets BS.3535: 1996 making itsafe for use in bathrooms. Insertion of a shaver plugautomatically switches on byenergising the primary side of theisolating transformer – removalautomatically switches off. Thetransformer is protected againstoverload by an automatic solidstate overload device withautomatic resetting.DIMENSIONS: 146 x 86mmFIXING CENTRES: 120.6mm.BS EN 61558-2-5: 1998
K703 MCOK703 SAB DUAL VOLTAGE115/230V OUTPUT(220/240V 50HZ INPUT)
K707 MCOK707 SAB DUAL VOLTAGE115/230V OUTPUT(120/130V 50HZ/60HZ INPUT)(NON UK)
1
1
1
1
MOUNTING BOXES
FLUSH:866 ZIC
SURFACE (MCO) WITH KNOCKOUTS:K899 ALM
WITHOUT KNOCKOUTS:K829 ALM
Cable diameter:Minimum 4mmMaximum 14.5mm
DIMENSIONS:1 gang: 86 x 86mm
FIXING CENTRES:
1 gang: 60.3mm
K2240 MCOK2240 SAB FLEX OUTLET
1
1
MOUNTING BOXES
FLUSH: 3995 ZIC
SURFACE (MCO) :WITH KNOCKOUTS: K899 ALMWITHOUT KNOCKOUTS: K829 ALM
These switches do not have to bederated when used with fluorescentor inductive loads.
Switches can be wired as eitherone-way or two-way. DIMENSIONS: 86 x 86mmFIXING CENTRES: 60.3mmBS EN 60669-1:2000If an intermediate switch isrequired, a modular (Grid Plus)version is available. Order K3431MCO/SAB grid plate, K3701 gridframe and K4893 WHI 20Aintermediate switch.
K4671 MCOK4671 SAB 1 GANG SP TWO-WAY
K4672 MCOK4672 SAB 2 GANG SP TWO-WAY
K4673 MCOK4673 SAB3 GANG SP TWO-WAY
5
5
5
5
5
5 K4761 MCOK4761 SAB1 GANG SP TWO-WAYWIDE ROCKER
K4762 MCOK4762 SAB2 GANG SP TWO-WAYWIDE ROCKERS
5
5
5
5
K703 MCO
K707 SAB
K4671 MCO
K4671 SAB
K4672 MCO
K4673 SAB
K4761 MCO
K4761 SAB
K5114 MCO
K4762 MCO
K4762 SAB
K2240 MCO
K2240 SAB
3 Pole FanIsolator
10 AMP
FLUSH
K4860 MCOWITHOUT SWITCHLOCK
K4860 SABWITHOUT SWITCHLOCK
K4858 SWITCHLOCK FOR FAN ISOLATOR
10
1
1
K4858
K4860 MCO
MOUNTING BOXES
FLUSH: 3995 ZIC
SURFACE: K2160 WHI
For local isolation of fanswith or without timers forrepair or routinemaintenance.
DIMENSIONS:86 x 86mm
FIXING CENTRES:60.3mm
BS EN. 60947-3: 1992
K4860 SAB
Standard Dimmer Switches
230V a.c. 50Hz
TUNGSTEN FILAMENT
FLUSH
230V a.c. 50Hz
TUNGSTEN FILAMENT
AND LOW VOLTAGE
FLUSH
Dimmer Switches(NON UK)
200-240V a.c.
50Hz or 60Hz
FLUSH
127V a.c. 60Hz
FLUSH
Blank Plates
FLUSH
K1532 MCOK1532 SAB1 GANG TWO WAY DOUBLE40W, 250W max for each dimmer
K1533 MCOK1533 SAB2 GANG TWO WAY TRIPLE40W min, 250W max for each dimmer
K1534 MCOK1534 SAB1 GANG TWO WAY SINGLE40W min, 250W max
K1551 MCOK1551 SAB1 GANG TWO WAY SINGLE60W min, 500W max
K1552 MCOK1552 SAB2 GANG TWO WAY DOUBLE60W min, 450W max for each dimmer
11
11
11
11
11
Conforming to relevant parts of BS 5515, these dimmers are suitablefor use with tungsten filament lampsonly. NOTE: Dimmer switchesspecified to work at 50Hz arenot really suitable for use at60Hz and vice versa.The one way dimmers use rotaryon/off switches, while the two waydimmers use push on/push offswitches.These dimmer switches are notsuitable for use with fluorescentloads or with electronic or with wire-wound transformers in low voltagelighting systems
Conforming to the latest standardsBS EN 60669-2-1 and BS EN 55015,they are overload protected and aresuitable for use with tungstenfilament lamps only.Two way dimmers use push on/pushoff switches.They are not suitable for usewith fluorescent loads or withelectronic or with wire-woundtransformers in low voltagelighting systems
Conforming to the latest standardsBS EN 60669-2-1 and BS EN 55015,they use ‘state of the art’ microcontroller based circuitry to providesoft start and overload protection.The soft start feature helps in greatlyprolonging the life of tungsten,normal or halogen lamps.Suitable for use with good qualityelectronic or wire woundtransformers. Can also be used withgood quality mains voltage halogenlamps incorporating GU10 bases.Please check with lamp manufacturerto determine suitability.Not suitable for use with fluorescent loads.
K1536 MCO LVK1536 SAB LV 1 GANG TWO WAY SINGLE40W/VA min, 300W/240VA max
K1532 MCO LVK1532 SAB LV 1 GANG TWO WAY DOUBLE40W/VA min, 300W/240VA max foreach dimmer
K1551 MCO LVK1551 SAB LV1 GANG TWO WAY SINGLE60W/VA min, 500W/400VA max
K1552 MCO LVK1552 SAB LV2 GANG TWO WAY DOUBLE60W/VA min, 450W/360VA max for eachdimmer
11
11
11
11 K1531 MCO
K1531 SAB1 GANG ONE WAY 40–250W 50Hz
K1541 MCOK1541 SAB1 GANG SINGLE ONE WAY 75–500W 50Hz
K1561 MCOK1561 SAB1 GANG SINGLE TWO WAY 100–1000W 50Hz
K1631 MCOK1631 SAB1 GANG SINGLE ONE WAY 40–250W 60Hz
K1641 MCOK1641 SAB1 GANG SINGLE ONE WAY 75–500W 60Hz
K1661 MCOK1661 SAB1 GANG SINGLE TWO WAY 100–1000W 60Hz
11
11
11
11
11
11 K1731 MCO
K1731 SAB 1 GANG SINGLE ONE WAY 40–250W
K1741 MCOK1741 SAB 1 GANG SINGLE TWO WAY 60–450W
K1761 MCOK1761 SAB 2 GANG SINGLE TWO WAY 90–650W
11
11
11
MOUNTING BOXES
FLUSH:1 GANG:866 ZIC2 GANG:886 ZIC
SURFACE (MCO) : WITH KNOCKOUTS: 1 GANG:K899 ALM2 GANG:K897 ALMWITHOUT KNOCKOUTS: 1 GANG:K829 ALM2 GANG:K830 ALMDIMENSIONS:1 gang: 86 x 86mm 2 gang: 86 x 146mm
FIXING CENTRES:1 gang: 60.3mm
K3330 MCOK3330 SAB 1 GANG
K3329 MCOK3329 SAB 2 GANG
5
5
10
10
Intelligent Dimmer Switches
K1731 MCO
K1731 SAB
K1741 MCO
K1761 SAB
K1536 MCO LV
K1532 SAB LV
K1532 MCO
K1533 SAB
K1534 MCO
K1631 MCO
K1641 SAB
K1661 MCOK1551 MCO LV
K1661 SABK1552 SAB LV
K3330 MCO
K3329 SAB
K1551 SAB
123Albany Plus
TECHNICAL HOTLINE +44 (0)1268 563720 DECORATIVE
MOUNTING BOXES FOR DIMMERSFLUSH: 1 gang: 861 ZIC 25mm deep min
2 gang: 862 ZIC 25mm deep min866 ZIC: 35mm min for
K1532 MCO LVK1532 SAB LV
DIMENSIONS: 1 gang: 86 x 86mm 2 gang: 86 x 146mm
FIXING CENTRES: 1 gang: 60.3mm 2 gang: 120.6mm
Albany Plus124
DECORATIVE www.mkelectric.co.uk
TV/FM CoaxialSocket Outlets
FLUSH
Satellite Socket Outlets
FLUSH
Telephone Outlets(NON UK)
3 PINFLUSH
Euro, LJU6C andMK Modular Data Frontplates
FLUSH
Grid PlusFrontplates
FLUSH
MOUNTING BOXES
FLUSH: 861 ZIC
SURFACE (MCO) : WITH KNOCKOUTS: K899 ALMWITHOUT KNOCKOUTS: K829 ALMK3580Single outlet for connection to asingle TV or FM co-axial aerial lead.
K3581, K3582Provides safety isolation rated at2000Va.c. between aerial lead andsocket. Single outlet for connectionto a single TV or FM co-axial aeriallead. Twin outlet with TV/FMdiplexer for connection to single co-axial aerial lead with combined TV& FM signals. Suitable for UHF TVand VHF FM radio.
K3580 MCOK3580 SAB SINGLE OUTLET (NON ISOLATED)
K3581 MCOK3581 SAB SINGLE OUTLET (ISOLATED)
K3582 MCOK3582 SAB TWIN OUTLET WITH TV/FM DIPLEXER (ISOLATED)
5
5
5
5
5
5
IEC 169-2: 1965
DIMENSIONS: 86 x 86mm
FIXING CENTRES: 60.3mm
BS. 5733: 1995where applicable
K3585 MCOK3585 SAB SINGLE OUTLET F TYPE SATELLITE SOCKET
1
1
Accepts standard BS.646 2 amp 2 pin + earth plug where 2pins are used for telephone circuitsand the earth pin is used to ensurecorrect polarity.
DIMENSIONS: 86 x 86mm
FIXING CENTRES: 60.3mm
BS. 5733: 1995where applicable
K3530 MCOK3530 SAB 3 PIN SOCKETWITH TELEPHONE SYMBOLSINGLE OUTLET
11
K3585 MCO K182 MCO
K172 SAB
K391 MCO
K394 SAB
K3433 MCO
K3436 SAB
K3585 SAB
K3530 MCO
K3530 SAB
K3581 MCO
K3582 SAB
K3580 MCO
K3580 SAB
K3431 MCOK3431 SAB1 MODULEK3432 MCOK3432 SAB2 MODULEK3433 MCOK3433 SAB3 MODULEK3434 MCOK3434 SAB4 MODULEK3436 MCOK3436 SAB6 MODULEK3438 MCOK3438 SAB8 MODULEK3439 MCOK3439 SAB9 MODULEK3442 MCOK3442 SAB12 MODULEK3448 MCOK3448 SAB18 MODULEK3454 MCOK3454 SAB24 MODULEK3401 MCOK3401 SABARCHITRAVE 1 MODULE
For a complete selection of Grid Plusswitch modules see pages 149 – 153
DIMENSIONS: Architrave: 118 x 38mm1 & 2 module: 86 x 86mm3 & 4 module: 86 x 146mm6 & 8 module:146 x 146mm9 & 12 module: 206 x 146mm18 module: 206 x 206mm24 module: 206 x 267mmBS.5733: 1995
1010
11
11
11
11
11
11
55
55
1010
1010
EUROK182 MCOK182 SAB2 MODULEK184 MCOK184 SAB4 MODULE
LJU6CK172 MCOK172 SAB2 MODULE
MK MODULARK391 MCOK391 SAB1 MODULEK392 MCOK392 SAB2 MODULEK393 MCOK393 SAB3 MODULEK394 MCOK394 SAB4 MODULEFor a complete selection of Euro, LJU6C and MK Modular Data modules and more information see pages 164-165 (MK Modular), 30-32 and164-165 (Euro / LJU6C)DIMENSIONS: 1 & 2 module: 86 x 86mm3 & 4 module: 86 x 146mmBS.5733: 1995Note: LJU6C and Euro Data Frontplates: nogrid required, modules just clip into place.MK Modular require appropriate grid.
55
55
1010
1010
55
55
55
Fully screened modularTV/Satellite outlets are
available to fit Eurofrontplates.
See page 31 for details.
In the busy telemarketing environment, employees can easily become tired and
irritable. Employers are forever looking for ways of improving this. Changing the
environment in which employees work is a highly effective means. This has been
successfully achieved by Cellular Operations plc UK, through the creation of an
innovative structure.
The Cellular Operations HQ Building is based in Swindon and has been designed by
Richard Hywel Evans, with MK products specified.
The buildings shape is not only a design feature, but it possesses a practical purpose
within its environment. The design allows in streams of natural daylight, and the
adjoining lake also functions as the key element in a simple ventilation system.
The office has been celebrated as “the happiest work place in Britain” and turnover
has significantly increased since its creation.
Architect Richard Hywel Evans Architecture and Design Ltd
M&E Consultant Curona Design
Contractor Tilbury Douglas
Project Manager/Quantity Surveyor EC Harris
Cellular Operations, Swindon
125Case Study
TECHNICAL HOTLINE +44 (0)1268 563720