EQ EQ EQ EQ EQ
3350
5000
1250
2500 6260 1460 3550
13770
23
0
26
50
90
20
30
23
0
27
80
90
50
00
31
00
60
0
830
90 1
00
0
15
00
13770 37503480
2500
230
6030
230
1000
230
3320
230
75
00
18
07
18
02
30
2305550
2305030
2301140
1801000
1803480
30
00
30
00
30
00
C/LC/LC/LC/LC/L
152mm x 152mm x 6mm HOT DIPPEDGALVANIZED MILD STEEL BASEPLATE, FIXED TO CONCRETE WITH 4 x M12 BOLTS
TYPICAL PERGOLA FRONT ELEVATIONscale 1 : 50
50mm x 152mmGALVANIZEDSTEEL SQUARE TUBING WELDED TO 152 x 152 x6mm BASEPLATE
50mm X 152mm PAR HARDWOODTIMBER MEMBER
50mm x 152mm GALVANIZEDSTEEL SQUARE TUBE SPACER
C/L1. THE CONTRACTOR MUST ESTABLISH THE POSITIONS OF BOUNDARY PEGS,EXISTING STRUCTURES & OBSTRUCTIONS BEFORE ANY WORK COMMENCES. 2. ANY EXCAVATION FOR ANY FOUNDATION MUST BE DONE UNTIL STABLE NATURAL GROUND IS REACHED AND NOT IN FILLED GROUND. 3. WHERE A FOUNDATION WALL IS HIGHER THAN 1 500mm A RETAINING WALL ACCORDING TO ENGINEERS SPECIFICATION MUST BE CONSTRUCTED. 4. FLOORSLABS TO BE CAST A MINIMUM OF 170mm (2 BRICK COURSES) ABOVE NATURAL GROUND LEVEL. 5. PREFABRICATED CONCRETE LINTOLS TO BE BUILT IN OVER ALL OPENINGS.LINTOLS MUST HAVE BEARING DISTANCE OF MINIMUM 225mm AT BOTH SIDES.
6. ALL WALLS TO HAVE "Brick-Force" AT EVERY 5TH COURSE.CAVITY WALLS TO HAVE MINIMUM OF 5 X WIRE TIES PER SQ/M. 7. "Brick-Force" FOR MINIMUM 4 BRICK COURSES ABOVE LINTOL HEIGHT. 8. ALL CARE MUST BE TAKEN TO KEEP CAVITIES CLEAN FROM DPC LEVEL TO EAVES LEVEL. 9. BEAM FILLING TO UNDERSIDE OF ROOF COVER. 10. ROOF OVERHANG : 300mm 11. ANY PERCEIVED INDISTINCTNESS OR CONTRADICTION IN THE DOCUMENTS MUST IMMIDIATELY BE CLEARED WITH THE ARCHITECT.
12. ALL GUTTERS AND DOWNPIPES TO BE ALLUMINIUMAND TO BE INSTALLED AS MANUFACTURER'S SPECIFICATION.
pavingDRIVE WAY
TO MUNICIPALCONNECTION
GROUND STOREY PLAN/SITE PLANscale 1 : 100
NOTES
PROPOSED NEW DWELLINGFOR MSP DEVELOPMENTS
ON ERF 879,(TYPE B)KRAAIFONTEIN
L2016116
drw no.
drawn
rev.
JAN 2017
date
job no.
1:100@A3
scale
drawing title
LRB
project
revision/issueno. date
architect
CONTRACTOR
COUNCIL DRAWINGS:
GROUND STOREY PLAN/SITE PLAN
WD-01
Old Castle Brewery Unit 005 6 Beach Road Woodstock 7925
Email. [email protected]. 021 447 1125Fax. 021 447 7347Cell. 082 823 1449
IN ASSOCIATION WITH WILHELM MARTIN BASSON ARCHITECTS cc.WORCESTER
H. LE ROUX BASSONNDIP ARCH(CAPE TECH)
B.BUILD(UPE) B.ARCH(UPE)SACAP REG. NO. 6 135
ALL WORK TO BE DONE IN ACCORDANCE WITH THENATIONAL BUILDING REGULATIONS (SOUTH AFRICANCODE OF PRACTICE) AND BUILDING STANDARDS ACT,ACT SABS 10400:2010
ALL SPECIFICATIONS ETC. TO BE IN ACCORDANCEWITH MODEL PREAMBLES FOR TRADES AS PUBLISHEDBY THE ASSOCIATION OF SOUTH-AFRICAN QUANTITYSURVEYORS.
ALL MATERIALS ETC. TO BE FITTED IN STRICTACCORDANCE WITH MANUFACTURERS' SPECIFICATIONS.
CONTRACTOR TO ALLOW FOR ARCHITECTS BOARD ALL ELECTRICAL WIRES IN WALLS, FLOORS ANDCONCRETE CEILINGS TO RUN IN SABS APPROVED CONDUITS
REGULATIONS AND REQUIREMENTS OF ALL RELEVANTAUTHORITIES TO BE ADHERED TO.CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELSON SITE BEFORE COMMENCING WITH WORK.FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TOSCALED MEASUREMENTS.ALL STRUCTURAL DESIGN TO BE THE RESPONSIBILITYOF A PROFESSIONAL ENGINEER.COPYRIGHT RESERVED.
GENERAL NOTES
DRAINAGE NOTES
ALL DRAINAGE TO BE IN ACCORDANCEWITH MUNICIPAL REGULATIONS.ALL UNDERGROUND PIPES TO BE 110mmDIAMETER P.V.C. PIPES.ANY DRAINAGE PIPE THAT RUNSBENEATH A CONCRETE SLAB TO BEENCASED IN 100mm CLEAN SANDSURROUND.ALL VENT PIPES & WASTEPIPES TO BE 50mm DIAMETER.
MOVEMENT JOINT NOTES:
CONTRACTOR TO ALLOW FOR MOVEMENT JOINTSIN FLOOR SLABS & WALLS WHERE DEAMEDNECESSARY.JOINTS TO BE SEALED WITH"JOINTEX"
HOT WATERSERVICES NOTES:
-A MIN. OF 50% OF WATER HEATING REQUIREMENTS TO BE PROVIDED BY RENEWABLE MEANS.-SOLAR WATER HEATING SYSTEM SHALL COMPLY WITH SANS 1307 & SANS 10106-THERMAL PERFORMANCE TO BE DETERMINED IN ACCORDANCE WITH SANS 6211-1 & SANS 6211-2.-SOLAR WATER HEATING SYSTEM INSTALLATION TO COMPLY WITH SANS 10254-HOT WATER CYLINDER TO RECEIVE 50mm THICK, NON-COMBUSTIBLE, LIGHTWEIGHT GLASSWOOL "ISOVER - GEYSER BLANKET". SEAL EDGES WITH DUCT TAPE. APPLY 2m OF 20mm THICK "SNAP-ON PIPE" INSULATION ON THE INCOMING COLD WATER PIPES.-ALL EXPOSED PIPES TO & FROM HOT WATER CYLINDER TO BE INSULATED WITH RIGID NON- COMBUSTIBLE LIGHTWEIGHT "ISOVER - GEYSER PIPE INSULATION" GLASSWOOL INSULATION WITH A WALL THICKNESS OF 35mm. INSTALLED IN ACCORDANCE WITH MANUFACTURER'S DETAIL AND SPECIFICATIONS.
FENESTRATIONNOTES:
REFER TO "ANNEXUREA" FOR FENESTRATIONCALCULATIONS
ST
ER
LIN
G G
RO
VE
CR
ES
CE
NT
ADJACENTERF 878
ADJACENTERF 880
1800mm HIGH, PRECAST CONCRETE WALL
wc
STAIRS:RISERS: 194mmTREADS: 250mm
W6
W5 W4 W3
W2
W1
CLASS EFIRE DOOR (30min)
TO SANS 1253
FIRE WALL TOU/S OF SLAB
PC
RE
INF
OR
CE
DC
ON
CR
ET
ELIN
TO
LS
OV
ER
2400 x
2100m
mS
EC
TIO
NA
LO
VE
RH
EA
DG
AR
AG
E D
OO
R
21 000mm BOUNDARY LINE
21 000mm BOUNDARY LINE
3100m
mC
WC
9 0
10m
m B
OU
ND
AR
Y L
INE
9 0
00m
m B
OU
ND
AR
Y L
INE
f/fr
wm
FFL: 94 495
FFL: 94 670
stovesink
D3
LOUNGEtiles tiles
KITCHEN
pavingCARPORT
PATIOtiles
GARAGEgranolithic
screed
tilesFOYER
GUESTWCtiles
ERF 879
re 2re 1
UNIT 49
UNIT 50
ERF 879
ERF 878
ADJACENTERF 882
ADJACENTERF 881
14131211109
8 7
654321
BB
A
A
1800mm HIGH, PRECAST CONCRETE WALL
DININGtiles
re 4re 3
paving
prepbowl
braai
hwb
PLATFRO
M LEVEL
94 415
FFL: 94 585
BUILDING LINES (BACK) N/A
FLOOR FACTOR 0,840
FOOTPRINT
proposed
COVERAGE
TOTALDESCRIPTION
THE BUILDING: TYPE B
86m²
45.50%
1MAX. FLOOR FACTOR
N/AMAX. FLOOR SPACE
N/ABUILDING LINES (STREET)
MAX. HEIGH (ROOF)
8 000mmMAX. HEIGH (WALLPLATE)
10 000mm
BUILDING LINES (COMMON)
ERF AREA
THE SITE
AREAS SCHEDULE: TYPE B
SERVITUDES
ZONING
N/A
GR1
189m²
N/A
BALCONY
TOTAL
GROUND STOREY 69,78m²
FIRST STOREY
69,78m²
58,62m² 58,62m²
4,96m² 4,96m²
PATIO
CARPORT
9,22m² 9,22m²
16,22m² 16,22m²
158,8m² 158,8m²
D1
D5
D2
D4
18
00
15902304100902000902940230
9680 1590
23
04
15
02
30
28
00
90
43
80
31
20
6490 3190230
2940
90
2000
90
910
230
2960
230
9680
23
03
62
09
03
47
09
0
75
00
29
30
901
00
090 27
0
1940
90
910
92
0
10
00
150
18
00
1 500 x 300 mm PRECASTCONCRETE INFILL PANELS.
150 x 150mm PRECAST CONCRETEPOSTS @ 1515mm C/C.
scale 1 : 50
BOUNDARY WALL DETAIL
1. THE CONTRACTOR MUST ESTABLISH THE POSITIONS OF BOUNDARY PEGS,EXISTING STRUCTURES & OBSTRUCTIONS BEFORE ANY WORK COMMENCES. 2. ANY EXCAVATION FOR ANY FOUNDATION MUST BE DONE UNTIL STABLE NATURAL GROUND IS REACHED AND NOT IN FILLED GROUND. 3. WHERE A FOUNDATION WALL IS HIGHER THAN 1 500mm A RETAINING WALL ACCORDING TO ENGINEERS SPECIFICATION MUST BE CONSTRUCTED. 4. FLOORSLABS TO BE CAST A MINIMUM OF 170mm (2 BRICK COURSES) ABOVE NATURAL GROUND LEVEL. 5. PREFABRICATED CONCRETE LINTOLS TO BE BUILT IN OVER ALL OPENINGS.LINTOLS MUST HAVE BEARING DISTANCE OF MINIMUM 225mm AT BOTH SIDES.
6. ALL WALLS TO HAVE "Brick-Force" AT EVERY 5TH COURSE.CAVITY WALLS TO HAVE MINIMUM OF 5 X WIRE TIES PER SQ/M. 7. "Brick-Force" FOR MINIMUM 4 BRICK COURSES ABOVE LINTOL HEIGHT. 8. ALL CARE MUST BE TAKEN TO KEEP CAVITIES CLEAN FROM DPC LEVEL TO EAVES LEVEL. 9. BEAM FILLING TO UNDERSIDE OF ROOF COVER. 10. ROOF OVERHANG : 300mm 11. ANY PERCEIVED INDISTINCTNESS OR CONTRADICTION IN THE DOCUMENTS MUST IMMIDIATELY BE CLEARED WITH THE ARCHITECT.
12. ALL GUTTERS AND DOWNPIPES TO BE ALLUMINIUMAND TO BE INSTALLED AS MANUFACTURER'S SPECIFICATION.
showershowershower
WCwhb
bath
WCwhb
VENTILATE HEAD OFDRAINAGE RUN
shower
WCwhb
bath
WCwhb
wmsss
94 415 94 415 94 415
93 707
708488
93 927
MH
TO MUNICIPALCONNECTIONTO MUNICIPALCONNECTION
MH
whbwhb
RE 3
sss
G
RE 2
sss
G
DRAINAGE SECTIONscale 1 : 100
DISTANCE
COVER LEVEL
INVERT LEVEL
DEPTH
FALL
450
RE 1
MIN. FALL 1 : 60
93 953
462
±15,17m
FALL
DEPTH
INVERT LEVEL
COVER LEVEL
DISTANCE
93 965
450
94 415
±0,85m
WC
ERF 878
ERF 879
UNIT 50
UNIT 49
PLATFRO
M LEVEL
94 415
1000mm HIGH BALUSTRADETO COMPLY WITH MUNICIPAL AND NBR REGULATIONS. NO GAP OR OPENING SHALL BE ABLE TO LET THROUGH ABALL OF NOT LESS THAN100mmø, AT ANY GIVENPOSITION OR POINT.bic
bic
bic
B B
carpetBEDROOM 2
9 0
00m
m B
OU
ND
AR
Y L
INE
9 0
00m
m B
OU
ND
AR
Y L
INE
21 000mm BOUNDARY LINE
21 000mm BOUNDARY LINE
shwr
bath
whb
wc
whb wc
shwr
FFL: 97 265
tilesBALCONY
123456
78
91011121314
carpetBEDROOM 3
FFL: 97 390
carpet
MAIN BEDROOM
tiles
EN-SUITE
tilesBATHR
A
A
W7
W8
W9W10W11
W12
W13
D6
geyser
trapdoor
NOTES
CONTRACTOR
architect
dateno. revision/issue
GENERAL NOTES
REGULATIONS AND REQUIREMENTS OF ALL RELEVANTAUTHORITIES TO BE ADHERED TO.CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELSON SITE BEFORE COMMENCING WITH WORK.FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TOSCALED MEASUREMENTS.ALL STRUCTURAL DESIGN TO BE THE RESPONSIBILITYOF A PROFESSIONAL ENGINEER.COPYRIGHT RESERVED.
ALL ELECTRICAL WIRES IN WALLS, FLOORS ANDCONCRETE CEILINGS TO RUN IN SABS APPROVED CONDUITS
CONTRACTOR TO ALLOW FOR ARCHITECTS BOARD
ALL MATERIALS ETC. TO BE FITTED IN STRICTACCORDANCE WITH MANUFACTURERS' SPECIFICATIONS.
ALL SPECIFICATIONS ETC. TO BE IN ACCORDANCEWITH MODEL PREAMBLES FOR TRADES AS PUBLISHEDBY THE ASSOCIATION OF SOUTH-AFRICAN QUANTITYSURVEYORS.
ALL WORK TO BE DONE IN ACCORDANCE WITH THENATIONAL BUILDING REGULATIONS (SOUTH AFRICANCODE OF PRACTICE) AND BUILDING STANDARDS ACT,ACT SABS 0400-1990.
H. LE ROUX BASSONNDIP ARCH(CAPE TECH)
B.BUILD(UPE) B.ARCH(UPE)SACAP REG. NO. 6 135
IN ASSOCIATION WITH WILHELM MARTIN BASSON ARCHITECTS cc.WORCESTER
Old Castle Brewery Unit 005 6 Beach Road Woodstock 7925
Email. [email protected]. 021 447 1125Fax. 021 447 7347Cell. 082 823 1449
project
LRB
drawing title
scale
1:100@A3
job no.
date
rev.
drawn
drw no.
L2016116
COUNCIL DRAWINGS:
FIRST STOREY PLANDRAINAGE SECTION
WD-02
JAN 2017
PROPOSED NEW DWELLINGFOR MSP DEVELOPMENTS
ON ERF 879,(TYPE B)KRAAIFONTEIN
scale 1 : 100
FIRST STOREY PLAN
1 800mm PRECAST CONCRETEBOUNDARY WALL.
CONCRETEPADFOUNDATION
D7
D8D9
D10
D11
7360
7360 MERANTI
TIMBER & STEELPERGOLA POST
152 x 50mm PARMERANTI MEMBERS@ MAX, 600mm C/C
EAST ELEVATIONscale 1 : 100
SOUTH ELEVATIONscale 1 : 100
L2016116
dateno. revision/issue
project
LRB
drawing title
scale
1:100
job no.
date
rev.
drawn
drw no.
COUNCIL DRAWINGS:
ELEVATIONS
WD - 03
Old Castle Brewery Unit 005 6 Beach Road Woodstock 7925
Email. [email protected]. 021 447 1125Fax. 021 447 7347Cell. 082 823 1449
IN ASSOCIATION WITH WILHELM MARTIN BASSON ARCHITECTS cc.WORCESTER
H. LE ROUX BASSONNDIP ARCH(CAPE TECH)
B.BUILD(UPE) B.ARCH(UPE)SACAP REG. NO. 6 135
architect
CONTRACTOR
ALL WORK TO BE DONE IN ACCORDANCE WITH THENATIONAL BUILDING REGULATIONS (SOUTH AFRICANCODE OF PRACTICE) AND BUILDING STANDARDS ACT,ACT SANS 10400:2011
ALL SPECIFICATIONS ETC. TO BE IN ACCORDANCEWITH MODEL PREAMBLES FOR TRADES AS PUBLISHEDBY THE ASSOCIATION OF SOUTH-AFRICAN QUANTITYSURVEYORS.
ALL MATERIALS ETC. TO BE FITTED IN STRICTACCORDANCE WITH MANUFACTURERS' SPECIFICATIONS.
CONTRACTOR TO ALLOW FOR ARCHITECTS BOARD ALL ELECTRICAL WIRES IN WALLS, FLOORS ANDCONCRETE CEILINGS TO RUN IN SABS APPROVED CONDUITS
REGULATIONS AND REQUIREMENTS OF ALL RELEVANTAUTHORITIES TO BE ADHERED TO.CONTRACTORS TO CHECK ALL DIMENSIONS AND LEVELSON SITE BEFORE COMMENCING WITH WORK.FIGURED DIMENSIONS TO BE TAKEN IN PREFERENCE TOSCALED MEASUREMENTS.ALL STRUCTURAL DESIGN TO BE THE RESPONSIBILITYOF A PROFESSIONAL ENGINEER.COPYRIGHT RESERVED.
GENERAL NOTES
NOTES
.
"S" = SAFETY GLASS"O" = OPAQUE GLASS
ALL GLASS AREASLARGER THAN 1m²OR LESS THAN 500mmFROM FLOOR LEVELTO RECIEVE SAFETYGLAZING INACCORDANCE WITHSANS 10400-N:2011.
GLASS THICKNESS:AS PER SANS10400-N:2011,4.2, TABLE 1
DOORS & WINDOWS:6mm TOUGHENEDSAFETY GLASS
PROPOSED NEW DWELLINGFOR MSP DEVELOPMENTS
ON ERF 879,(TYPE B)KRAAIFONTEIN
JAN 2017
8 000mm WALLPLATE HEIGHT RESTICTION
200 x 600MASS CONCRETESTRIP FOUNDATION
8 000mm WALLPLATE HEIGHT RESTICTION
scale 1 : 100NORTH ELEVATION
8 000mm WALLPLATE HEIGHT RESTICTION
BO
UN
DA
RY
LIN
E
BO
UN
DA
RY
LIN
E
BO
UN
DA
RY
LIN
E
BO
UN
DA
RY
LIN
E
CE
NT
RE
LIN
E
CE
NT
RE
LIN
E
CHIMNEY TO COMPLY WITH ALLRULES & REGULATIONS AS PERIN SANS 10400-V:2010 4.3ROOF TIMBERS TO STOP A MIN.OF 200mm AWAY FROM INSIDEWALL OF CHIMNEY.
BRICK WORK. SMOOTHPLASTERED & PAINTEDPLASCON PAINTFINISH ACCORDING TOMANUFACTURERSSPECIFICATION ORAPPROVED SIMILAR.COLOUR TO ARCHITECT'SSPECIFICATIONS.
1800mm HIGH, 140mmTHICK CONCRETEBLOCKWORK WALL
AD
JA
CE
NT
UN
IT
AD
JA
CE
NT
UN
IT
1000mm HIGH BALUSTRADETO COMPLY WITH MUNICIPALAND NBR REGULATIONS. NOGAP OR OPENING SHALL BEABLE TO LET THROUGH ABALL OF NOT LESS THAN100mmø, AT ANY GIVENPOSITION OR POINT.
EVACUATED TUBE COLLECTOR ACCORDINGTO SPECIALISTS SPECIFICATIONS
15mm PLASTERDETAIL TOARCHITECT'SSPECIFICATION
15mm PLASTERDETAIL TOARCHITECT'SSPECIFICATION
1000mm HIGH BALUSTRADETO COMPLY WITH MUNICIPALAND NBR REGULATIONS. NOGAP OR OPENING SHALL BEABLE TO LET THROUGH ABALL OF NOT LESS THAN100mmø, AT ANY GIVENPOSITION OR POINT.
228 x 50mm PARMERANTI BEARER
CHIMNEY TO COMPLY WITH ALLRULES & REGULATIONS AS PERIN SANS 10400-V:2010 4.3ROOF TIMBERS TO STOP A MIN.OF 200mm AWAY FROM INSIDEWALL OF CHIMNEY.
FIBRE CEMENTCLADDING