1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT PROJECT #16C1-010 TECHNICAL SPECIFICATIONS Volume II of III COUNTY OF SANTA CRUZ, CALIFORNIA GENERAL SERVICES DEPARTMENT June 27, 2017 PROPOSALS DUE: July 25, 2017 2:30 P.M. PROJECT NO.: #16C1-010 PRE-BID CONFERENCE: Tuesday, July 11, 2017 @ 10:00 am 1070 Emeline Avenue, Santa Cruz, CA VOLUME I: General and Supplemental Conditions VOLUME II: Technical Specifications VOLUME III: Bid Proposal For use in connection with Santa Cruz County standards and the 2016 California Building Code.

1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT

PROJECT #16C1-010

TECHNICAL SPECIFICATIONS

Volume II of III

COUNTY OF SANTA CRUZ, CALIFORNIA GENERAL SERVICES DEPARTMENT

June 27, 2017

PROPOSALS DUE: July 25, 2017 – 2:30 P.M. PROJECT NO.: #16C1-010

PRE-BID CONFERENCE: Tuesday, July 11, 2017 @ 10:00 am 1070 Emeline Avenue, Santa Cruz, CA VOLUME I: General and Supplemental Conditions VOLUME II: Technical Specifications VOLUME III: Bid Proposal For use in connection with Santa Cruz County standards and the 2016 California Building Code.

Page 2: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

ACCESS HATCHES

REMOVE WOOD AWNING. TO BE REPLACED IN FUTURE PROJECT.

REMOVE SIDING REPLACE WITH HARDIE BOARD TYP. REPLACE DOWNSPOUTS AND CONNECT TO EXISTING DRAINAGE PIPES, TYP.

EXISTING COMPOSITION ROOFING TO REMAIN. U.N.O.

REPLACE ALL GUTTERS

REMOVE AND REPLACE WITH LOUVRED VENTS AND INSECT SCREENS OF SAME AREA, TYP.

AREA NOT INCLUDEDIN PROJECT

CANVAS ON STEEL TUBULAR FRAME AWNINGS NOT SHOWN IN DETAIL FOR CLARITY. REMOVE AND SAVE, TYP.

Will

iam

Fis

her

Arc

hit

ectu

re, I

nc.

603

Fron

t Stre

et, S

anta

Cru

z, C

alifo

rnia

950

6083

1 24

6-01

17 fi

sher

@cr

uzio

.com

mod

ern-

arch

itect

ure.

com

LicensedArchitect

William FisherC−11008

10/31/17RENEWS ON

AINOFILA

R

C

COPYRIGHT 2017, WILLIAM FISHER ARCHITECTURE, INC.

3/14/2017

Bui

ldin

g G

Rem

odel

Emeline Avenue County Building G Remodel

1400

Em

elin

e A

venu

e, 1

070-

A1

San

ta C

ruz

Cou

nty

San

ta C

ruz,

950

60

A-1

1/8" = 1'-0"1 East (Proposed)

1/8" = 1'-0"2 North (Proposed)

1/8" = 1'-0"3 South (Proposed)

1/8" = 1'-0"4 West (Proposed)

PROJECT DESCRIPTIONRemove existing awnings, save steel awning frames for future re-canvasing. Remove and replace all windows. Remove and replace all gutters and downspouts. Remove existing wood siding replace with HardiePlank lap siding on entire exterior. Remove and replace basement door on west side of building, replace concrete landing at basement door and install trench drain.

Vicinity Map(not to scale)

Index

A-1 Elevations, NotesA-2 Floor Plans, Details

DON'T SCALE THE DRAWINGS.

"ALIGN" MEANS TO LOCATE FINISHED FACES IN SAME PLANE.

"APPROVED" MEANS, UNLESS INDICATED OTHERWISE BY THE ARCHITECT, APPROVED IN WRITING BY THE ARCHITECT.

"AS DIRECTED" OR "AS INDICATED" MEANS AS DESCRIBED EITHER VERBALLY OR IN WRITING BY THE ARCHITECT. "AS INDICATED" NORMALLY REFERS TO AN ITEM EXPLAINED IN THE CONTRACT.

"THE CONTRACTOR" REFERS TO THE GENERAL CONTRACTOR, NOT HIS SUBCONTRACTORS.

"PROVIDE" MEANS THAT THE CONTRACTOR SHALL FURNISH AND INSTALL.

"UNLESS NOTED OTHERWISE", "UNO", OR "UNLESS INDICATED OTHERWISE" MEANS THAT THE ITEM DESCRIBED IS TYPICAL AS SHOWN EXCEPT AS WHERE SPECIFICALLY CALLED OUT AS DIFFERENT.

"VERIFY" MEANS, UNLESS INDICATED OTHERWISE BY THE ARCHITECT, TO OBTAIN WRITTEN VERIFICATION OF THE ITEM OR METHOD INDICATED FROM THE ARCHITECT. THIS VERIFICATION MIGHT INCLUDE ELABORATION OR EXPLANATION BY THE ARCHITECT REQUIRING A MORE COMPLEX CONSTRUCTION SOLUTION THAN MIGHT BE ASSUMED BY READING THE DRAWING WITHOUT THE VERIFICATION, THEREFORE PLEASE MAKE VERIFICATIONS AS EARLY AS POSSIBLE BEFORE BIDDING THE WORK. APPROVED SHOP DRAWINGS DO NOT CONSTITUTE VERIFICATION.

WORK NOTED "BY OTHERS" OR "N.I.C." (NOT IN CONTRACT) WILL BE PROVIDED BY OWNER OR UNDER A SEPARATE CONTRACT. INCLUDE TIME FOR THIS WORK IN CONSTRUCTION PROGRESS SCHEDULE AND COORDINATE AS REQUIRED TO ASSURE ORDERLY SEQUENCE OF INSTALLATION.

DIMENSIONS MARKED "CLEAR" SHALL BE MAINTAINED AND SHALL ALLOW FOR THICKNESS OF FINISH MATERIALS.

UNLESS INDICATED OTHERWISE, UNDERCUT DOORS 1/4 INCH MAXIMUM TO CLEAR TOP OF FLOOR FINISHES.

UNLESS INDICATED OTHERWISE, PROVIDE 4 INCH SMOOTH RUBBER COVE BASE.

THE ARCHITECT, AS USED HEREIN, REFERS TO WILLIAM FISHER ARCHITECTURE, INC., REPRESENTED BY WILLIAM FISHER, PRESIDENT. WILLIAM FISHER ARCHITECTURE, INC. MAY HEREIN ALSO BE KNOWN AS "WF", "WILLIAM FISHER ARCHITECTURE", OR "WFA."

REPAIR ALL WALLS WITH FIVE EIGHTS INCH THICK TYPE-X GYPSUM BOARD TYPICALLY. FEATHER PATCHES SO AS TO BE IMPERCEPTIBLE WITH THE NAKED EYE AT A DISTANCE OF 36 INCHES.

INFORM THE ARCHITECT IMMEDIATELY IF THE DRAWINGS, SPECIFICATIONS, OR OTHER CONSTRUCTION DOCUMENTS DON'T SEEM TO COMPLY WITH CURRENT APPLICABLE LAWS, CODES OR REGULATIONS.

DISCONNECT, CUT BACK TO THEIR SOURCE UTILITIES TO BE REMOVED. SEAL PENETRATIONS AND OTHER DAMAGE CREATED BY UTILITY REMOVAL TO MATCH ADJACENT CONSTRUCTION AND FINISHES. NOTIFY ARCHITECT IMMEDIATELY OF UTILITIES DETERMINED DURING CONSTRUCTION AS NECESSARY TO BE REMOVED WHICH HAVE NOT BEEN SO DESIGNATED IN THE CONTRACT DOCUMENTS. REMOVE SUCH UTILITIES ONLY AFTER CONSULTATION WITH THE ARCHITECT.

STUDY THE CONTRACT DOCUMENTS AND THE FIELD CONDITIONS BEFORE BIDDING OR DOING WORK ON THIS PROJECT. IMMEDIATELY REPORT TO THE ARCHITECT ANY ERRORS, OMISSIONS, OR UNCLEAR DIRECTIONS. THE ARCHITECT WILL EVALUATE THE PROBLEM AND MAKE AN INTERPRETATION.

THE CONTRACTOR SHALL VERIFY AND BE RESPONSIBLE FOR ALL DIMENSIONS AND CONDITIONS ON THE PROJECT. THE ARCHITECT MUST BE NOTIFIED IMMEDIATELY OF ANY DEVIATIONS OR VARIATIONS FROM THE DRAWINGS OR SPECIFICATIONS SHOWN HEREIN.

OBTAIN ALL PERMITS AND INSPECTIONS AND COMPLY WITH ALL CODES, LAWS, RULES, ORDINANCES, AND REGULATIONS OF ALL PUBLIC AUTHORITIES (FEDERAL, STATE, AND LOCAL) GOVERNING THE WORK. THE MOST STRINGENT SHALL APPLY.

SUBSTITUTIONS, REVISIONS, OR CHANGES, MUST BE SUBMITTED TO ARCHITECT FOR REVIEW, BEFORE PURCHASE OR FABRICATION OF ITEM(S) IN QUESTION.

IN ADDITION TO ANY OTHER CONDITION OR REQUIREMENT OF THE CONTRACT, THE FOLLOWING PARAGRAPH APPLIES TO ALL SUBMITTALS, INCLUDING BUT NOT LIMITED TO SHOP DRAWINGS, PRODUCT DATA, SAMPLES, OR QUALIFICATION INFORMATION. ONLY SUBMIT SUBMITTALS THAT ARE REQUIRED BY THE CONTRACT OR HAVE BEEN REQUESTED BY ARCHITECT. SUBMITTALS MUST BE DELIVERED TO ARCHITECT AND NOT DIRECTLY TO HIS CONSULTANTS. SUBMITTALS WILL BE REVIEWED BY ARCHITECT OR HIS CONSULTANTS ONLY IF APPROVED FIRST BY THE GENERAL CONTRACTOR. BEFORE SENDING ANY SUBMITTAL TO ARCHITECT, GENERAL CONTRACTOR MUST FIRST REVIEW SUBMITTAL AND WET SIGN ONE COPY TOGETHER WITH THE WORD "APPROVED." THIS APPROVAL MEANS THAT THE GENERAL CONTRACTOR CERTIFIES THAT THE PRODUCTS, MATERIALS, AND MECHANISMS DESCRIBED IN THE SUBMITTAL ARE PROPER FOR ITS INTENDED USE IN THE PROJECT, AND WILL BE COMPATIBLE WITH ALL PRODUCTS AND MATERIALS EXISTING AND TO BE INSTALLED AS PART OF THIS PROJECT. IF ARCHITECT OR HIS CONSULTANTS APPROVE, OR REVIEW WITH NO EXCEPTIONS TAKEN, A SUBMITTAL, SUCH ACTION DOES NOT ALLEVIATE THE GENERAL CONTRACTOR'S DUTY DESCRIBED HERE.

MAINTAIN FOR THE ENTIRE DURATION OF THE WORK, EXITS, EXIT LIGHTING, EXIT SIGNAGE, FIRE PROTECTION DEVICES AND ALARMS, PER THE REQUIREMENTS OF GOVERNING PUBLIC AUTHORITIES.

U.N.O., APPLY, INSTALL, CONNECT, ERECT, CLEAN, AND CONDITION PRODUCTS PER THEIR MANUFACTURER'S CURRENT WRITTEN INSTRUCTIONS.

ONLY INSTALL MATERIALS ON CLEAN AND PROPER SUBSTRATES. STARTING INSTALLATION INDICATES CONTRACTOR'S ACCEPTANCE OF SUBSTRATE.

VERIFY WITH MANUFACTURERS, THEIR EQUIPMENT REQUIREMENTS (FOR INSTANCE, STRUCTURAL BLOCKING OR SUPPORT, ELECTRICAL OR MECHANICAL REQUIREMENTS, ETC.). OBTAIN EQUIPMENT SPECIFICATIONS FROM MANUFACTURER(S) TO HELP ENSURE PROPER FIT AND OPERATION.

PROTECT THE BUILDING AND OTHER PROPERTY FROM ANY DAMAGE DURING CONSTRUCTION. THE CONTRACTOR WILL BE FINANCIALLY RESPONSIBLE FOR ANY NECESSARY REPAIRS.

COORDINATE WITH OWNER TIMES AND LOCATIONS FOR PARKING, TOOL STORAGE, MATERIAL STORAGE DELIVERIES, BUILDING ACCESS, AND PUBLIC AREAS.

NO HAZARDOUS MATERIAL TO BE USED AND/OR STORED ON SITE

RIVER

ST

MIS

SION

BLV

D

HWY 1

HW

Y 17

MAR

KET

SOQUEL

GRAHAM

HILL RD

HWY 9

EMEL

INE

SITE

S A N T A C R U Z

Page 3: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

DN

UP

DN

6A2

EXISTING FINISH TO REMAIN.

AT ALL INTERIOR WALLS WHERE WINDOWS ARE BEING REMOVED AND REPLACED, REPLACE INTERIOR WALL FINISH WITH 5/8" TYPE-X GYPSUM BOARD, TAPED AND TEXTURED TO MATCH EXISTING OR BETTER PAINTED WITH 2 COATS EGGSHELL KM "FROST" COLOR, OVER PRIMER RECOMMENDED BY PAINT MANUFACTURER. REPLACE ALL BASE IN AFFECTED ROOMS AND SPACES WITH BURKE RUBBER BASE (COLOR SELECTED BY COUNTY PROJECT REPRESENTATIVE).

REMOVE AND REPLACE (E) LEDGER

(E) SHEATHING

(E) FRAMING

5/16" HARDIEPLANK, "SMOOTH" LAP SIDING8" EXPOSURE CORNER WITH HARDIE TRIM CORNER BOARDS (COLOR TO BE SELECTEDBY COUNTY PROJECT REPRESENTATIVE)

(E) HANGERS

(E) JOISTS, TRIM AS REQUIRED

(E) DECKING

WATER RESISTANT BARRIER

PUCK SPACER, SET IN SEALANT

5/8" X 8" LAG SCREW WITH MALLEABLE WASHERS INTO STUDS @ 16" O.C. STAGGERED

2" SCHEDULE 40 PVCSLOPE TO DAYLIGHT

4A2

REPLACE DOOR AND FRAME

3" M

IN

0' - 3"

REPLACE DOOR

PEMKO 215V DARK BRONZE ANODIZED DOOR SHOE (OR EQUAL)

SLOPE AWAY FROM DOOR 2 : 1

PEMKO 227 DARK BRONZE ANODIZED THRESHOLD (OR EQUAL)CONFORM TO

EXISTING WALK

7" M

IN8" M

IN

NEW 3000# BROOM FINISHED CONCRETE

5/16" HARDIEPLANKLAP SIDING

1X WOOD SILL, PAINTED

(E) SHEATHING

ALUMINUM WINDOW FRAME, INSTALLED PER MANUFACTURER'S WRITTEN RECOMMENDATION

5/8" TYPE-X GYPSUM BOARD

(E) FRAMING

Will

iam

Fis

her

Arc

hit

ectu

re, I

nc.

603

Fron

t Stre

et, S

anta

Cru

z, C

alifo

rnia

950

6083

1 24

6-01

17 fi

sher

@cr

uzio

.com

mod

ern-

arch

itect

ure.

com

LicensedArchitect

William FisherC−11008

10/31/17RENEWS ON

AINOFILA

R

C

COPYRIGHT 2017, WILLIAM FISHER ARCHITECTURE, INC.

3/14/2017

Bui

ldin

g G

Rem

odel

Emeline Avenue County Building G Remodel

1400

Em

elin

e A

venu

e, 1

070-

A1

San

ta C

ruz

Cou

nty

San

ta C

ruz,

950

60

A-2 1/8" = 1'-0"1 Floor Plan

3" = 1'-0"6 Deck Connection

1/8" = 1'-0"3 Basement 3" = 1'-0"4 Trench Drain

3" = 1'-0"5 Typical Sill and Jamb

WINDOW SCHEDULE

1

2

3

4

6

7

ALL NEW WINDOWS TO BE MILGARD INTEGRITY ALL ULTREX, EXTERIOR COLOR OF WINDOWS TO BE SELECTED BY COUNTY PROJECT REPRESENTATIVE. ALL LITES FULLY TEMPERED (BOTH DUAL LITES TEMPERED).

1/8" = 1'-0"2 Proposed

1 1 1

1 1 12 2

2 2

3

4

4 4 4 444

5

5 5 5 56 6 6 6

7

77

THREE FACTORY MULLED, 3' - 0" X 6' - 0" DOUBLE HUNG

TWO FACTORY MULLED, 2' - 0" X 6' - 0" DOUBLE HUNG

TWO FACTORY MULLED, 3' - 6" X 6' - 0" DOUBLE HUNG

2' - 6" X 4' - 7" DOUBLE HUNG

2' - 0" X 3' - 0" DOUBLE HUNG

2' - 6" X 3' - 0" DOUBLE HUNG

3' - 0" X 5' - 0" DOUBLE HUNG

5 5

Page 4: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

ST E C HC O N S U L T I N G

484

-b washington street m

onterey, ca 93940 #

401 / p 831 883 84

15 / f 877 984 54

95 / [email protected]

/ stechconsulting.com

Limited Asbestos & Lead-Based Paint Survey Report Renovation, County Facility

Site: 1070 Emeline Avenue, Santa Cruz, California

S Tech Project: 16239

Prepared for: County of Santa Cruz

November 16, 2016

S Tech Consulting was retained by The County of Santa Cruz to conduct limited asbestos and lead-based paint sampling of the interior and exterior at a county facility located at 1070 Emeline Avenue in Santa Cruz, California. The renovation work will involve replacing the existing windows associated with the building. Due to the age of the structure, the planned improvements will impact suspect asbestos containing materials and lead-based paints.

Prior to conducting renovation or demolition, the EPA and Cal-OSHA require the sampling of building materials to determine whether asbestos is present. When asbestos is identified and will be disturbed, it must be handled and disposed of by trained and licensed personnel, to prevent the creation of an airborne asbestos hazard. Lead paint is regulated by EPA and OSHA to prevent creating a lead exposure hazard for workers and especially children. The EPA Renovation, Repair, and Painting Rule (RRP), requires either assuming pre-1978 structures contain lead-based paints or testing to prove otherwise.

The site visit took place on November 8, 2016 by Sean Tillema, a State of California Division of Occupational Safety and Health Certified Asbestos Consultant (07-4257), and California Department of Public Heath Certified Lead Related Construction Inspector / Risk Assessor (1646).

Scope of Work & Property Description

Our scope of work was limited to testing specific interior and exterior components that will be impacted by the renovation scope of work, as directed by the client. This was not a comprehensive assessment of all suspect materials associated with the structure. For the areas assessed, our assessment was in accordance with the requirements of the Monterey Bay Unified Air Pollution Control District (MBUAPCD). Lead testing was for compliance with the EPA RRP Rule and for Cal-OSHA Lead in Construction’s standard.

The subject property is a single-story building used County of Santa Cruz staff. The building was constructed prior to the 1940s. The project is to replace the existing windows associated with the building. The building was occupied and in fair condition at the time of the assessment.

The exterior of the building is clad in wood siding. Windows are wood with window putty present around the individual glass panes.

The interior walls within the assessment area are plaster.

Page 5: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

Limited Asbestos & Lead-Based Paint Assessment - 1070 Emeline Avenue, Santa Cruz, California

484

-b washington street m

onterey, ca 93940 #

401 / p 831 883 84

15 / f 877 984 54

95 / [email protected]

/ stechconsulting.com

Asbestos Containing Materials

Asbestos-containing material (ACM) is defined by the United States Environmental Protection Agency (EPA) as material containing more than one percent asbestos as determined by Polarized Light Microscopy (PLM). In California, for contractor licensing and employee protection, the California Department of Occupational Safety and Health (Cal-OSHA) classifies any material as having greater than one tenth of one percent (>0.1%) asbestos as Asbestos-Containing Construction Material (ACCM). Asbestos containing material are divided into friable and non-friable classifications. Friability refers to the likelihood of the material readily releasing airborne fibers when disturbed. Materials which are non-friable in-situ have the potential to become friable when deteriorated or when renovation or demolition occurs.

The following conclusions were arrived at from the field inspection and the analytical results:

✴ Asbestos was not identified in the materials anticipated to be impacted by the scope of the current renovations.

Analysis was performed by AmeriSci Los Angeles, a NVLAP accredited laboratory, on a standard laboratory turnaround time. Six samples were collected and submitted to the laboratory. Once at the lab, the submitted samples required no further separation. The table below is a listing of all materials collected from the site, with samples in red containing asbestos. The laboratory report is attached at the end of this document. See the summary for additional information.

A s b e s t o s B u l k S a m p l e T a b l eA s b e s t o s B u l k S a m p l e T a b l eA s b e s t o s B u l k S a m p l e T a b l eA s b e s t o s B u l k S a m p l e T a b l e

Sample Number Material Sampled Sample Location

Analytical ResultsNAD = No Asbestos Detected

239-1 Window Putty Exterior - Wood Windows NAD

239-2 Window Putty Exterior - Wood Windows NAD

239-3 Window Putty Exterior - Wood Windows NAD

239-4 Plaster Room #102 - Wall NAD

239-5 Plaster Room #102 - Wall NAD

239-6 Plaster Room #102 - Wall NAD

Page 6: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

Limited Asbestos & Lead-Based Paint Assessment - 1070 Emeline Avenue, Santa Cruz, California

484

-b washington street m

onterey, ca 93940 #

401 / p 831 883 84

15 / f 877 984 54

95 / [email protected]

/ stechconsulting.com

Lead-Based Paint

Lead-Based Paint (LBP), as defined by EPA, is of concern both as a source of direct exposure through ingestion of paint chips, and as a contributor to lead interior dust and exterior soil. Lead was widely used as a major ingredient in most interior and exterior oil-based paints prior to 1950. Lead compounds continued to be used as corrosion inhibitors, pigments and drying agents from the early 1950's. In 1972, the Consumer Products Safety Commission limited lead content in new paint to 0.5% (5000 ppm) and, in 1978, to 0.06% (600 ppm). Today, for purposes of lead-based paint inspection, for childhood lead poisoning prevention, EPA defines LBP as paint containing greater than 0.5% (5000 ppm) lead by weight or greater than 1.0 mg/cm2 by surface area. This report applies the 1.0 mg/cm2 reference standard, which applies to X-ray Fluorescence (XRF) testing.

As of April 22, 2010, the Environmental Protection Agency (EPA) enacted the LBP Renovation, Repair, and Painting Rule (RRP) to better protect building occupants, especially children, from lead exposure during construction activities. According to the RRP Rule, unless testing has proven otherwise, paints must be assumed to be LBP in pre-1978 housing, childcare facilities, schools, or other locations frequented by children. When work will impact assumed or identified LBP, property managers and/or contractors must be EPA RRP certified and are required to use lead-safe work practices, including HEPA vacuums and containment. Prior to conducting work, which disturbs LBP, homeowners or tenants must be provided the EPA brochure Renovate Right: Important Lead Hazard Information for Families, Child Care Providers, and Schools. Additionally, the landlord or contractor must document compliance with the hazard communication requirement by having the building resident sign the form at the back of the brochure. The signed form must be kept on file and provided to the EPA in the event of an audit or enforcement action.

The State of California has enacted a number of regulations to minimize lead exposure in children and adults. Specifically, Title 17, California Code Of Regulations, Division 1, Chapter 8 Accreditation, Certification, and Work Practices For Lead-Based Paint and Lead Hazards and a number of California Civil and Health and Safety Codes, provide requirements for lead-safe housing and the prevention of lead hazards from developing in housing. A complete list of all State of California LBP regulations is available at the CDPH Childhood Lead-Poisoning Prevention Branch website. The California Department of Public Health (CDPH) is the agency responsible for enforcing compliance with existing state LBP regulations.

For occupational lead exposure in the construction and building maintenance industries, lead is regulated below the threshold set by the EPA for lead-based paint. Additionally, OSHA does not limit lead health and safety requirements to paint. Many other building materials and manufactured items are known to contain lead. Adult occupational tasks may result in exposure to lead even when working with low lead concentrations. Tasks such as abrasive blasting, flame torch usage, and mechanical grinding are especially prone to occupational lead exposure. When lead is present in any concentration, Cal-OSHA, under Title 8 CCR Section 1532.1, requires employers to evaluate the task performed and conduct an exposure assessment. Based on the results of the exposure assessment, engineering controls and personal protective equipment may be necessary to reduce occupational lead exposure. Additional information is available from this Cal-OSHA fact sheet: http://www.dir.ca.gov/dosh/dosh_publications/lead-fct-sheet-rev.pdf

Paint testing at this property was conducted by X-ray Fluorescence (XRF), which provides instant onsite analysis, penetrating all paint layers.

The following conclusions were arrived at from the testing:

✴ Interior, EPA defined Lead-Based Paint (>1.0 mg/cm2 by XRF) was identified in coatings anticipated to be impacted by the scope of the renovations.

✴ Exterior, EPA defined Lead-Based Paint (>1.0 mg/cm2 by XRF) was identified in coatings anticipated to be impacted by the scope of the renovations.

✴ For contractor OSHA compliance, all paints have detectable lead content and are subject to the requirements of the Cal-OSHA Lead in Construction Standard (Title 8 CCR Section 1532.1) when conducting trigger tasks which could result in occupational exposure to lead. Tasks such as abrasive blasting, grinding, and flame torch typically are tasks that are most likely to result in high exposure to lead.

The table on the following page is a summary of components identified to contain lead based paint. Following the summary table is a table listing the results of all the components tested. See summary for additional information.

Page 7: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

Limited Asbestos & Lead-Based Paint Assessment - 1070 Emeline Avenue, Santa Cruz, California

484

-b washington street m

onterey, ca 93940 #

401 / p 831 883 84

15 / f 877 984 54

95 / [email protected]

/ stechconsulting.com

Lead-Based Paint - continued

The table below lists the painted and/or glazed components tested as part of this assessment. EPA Lead-Based Paint is lead content in excess of 5,000 ppm by bulk analysis or greater than 1.0 mg / cm2 by XRF. Note, lead in any amount may be regulated by Cal-OSHA for worker protection.

L e a d ( P b ) S a m p l i n g T a b l e L e a d ( P b ) S a m p l i n g T a b l e L e a d ( P b ) S a m p l i n g T a b l e L e a d ( P b ) S a m p l i n g T a b l e L e a d ( P b ) S a m p l i n g T a b l e

Location Component SubstrateAnalytical Results

XRF: mg/cm2 Classification

Exterior Siding Wood 3.85 Lead Based Paint

Room #102(Assumed similar conditions

throughout interior)

Original Window Components

Wood 4.43 - >5.00 Lead Based Paint

Room #102(Assumed similar conditions

throughout interior)

Wall Plaster 3.64 Lead Based Paint

Page 8: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

Limited Asbestos & Lead-Based Paint Assessment - 1070 Emeline Avenue, Santa Cruz, California

484

-b washington street m

onterey, ca 93940 #

401 / p 831 883 84

15 / f 877 984 54

95 / [email protected]

/ stechconsulting.com

Lead-Based Paint - continued

The table below lists the painted and/or glazed components tested as part of this assessment. EPA Lead-Based Paint is lead content in excess of 5,000 ppm by bulk analysis or greater than 1.0 mg / cm2 by XRF. Note, lead in any amount may be regulated by Cal-OSHA for worker protection.

L e a d ( P b ) C o n t e n t b y X - r a y F l u o r e s c e n c e L e a d ( P b ) C o n t e n t b y X - r a y F l u o r e s c e n c e L e a d ( P b ) C o n t e n t b y X - r a y F l u o r e s c e n c e L e a d ( P b ) C o n t e n t b y X - r a y F l u o r e s c e n c e

Area Component SubstrateLead Content

mg/cm2

Room #102 Window Sash Wood >5.00

Room #102 Window Sill Wood >5.00

Room #102 Window Frame Wood 4.43

Room #102 Wall Plaster 3.64

Exterior Siding Wood 3.85

Page 9: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

Limited Asbestos & Lead-Based Paint Assessment - 1070 Emeline Avenue, Santa Cruz, California

484

-b washington street m

onterey, ca 93940 #

401 / p 831 883 84

15 / f 877 984 54

95 / [email protected]

/ stechconsulting.com

Summary of Findings

Asbestos

Asbestos was not identified in the materials anticipated to be disturbed by the scope of the renovation. No further action, with regards to asbestos, is necessary to proceed with the demolition scope of work. However, contractors should be aware that concealed spaces may harbor additional suspect material. Asbestos cement pipes may be concealed within wall cavities and found in underground utility pipes. Should any additional suspect materials be identified during the course of the demolition work, stop work and contact us to assess and sample if necessary.

Regulated Asbestos Containing Material (RACM) will not be impacted by the scope of the current renovations. A notification to the Monterey Bay Unified Air Pollution Control District (MBUAPCD) would only be necessary if load bearing walls will be removed as part of this renovation project. If such work will occur, a notification for demolition must be submitted ten business days prior to the start of work.

Lead

Testing by X-ray Fluorescence (XRF) has determined EPA defined Lead-Based Paint (LBP) is present on both interior and exterior components associated with the building. Any disturbance to components coated with LBP should be done so using lead-safe work practices, including the usage of HEPA vacuums and containment.

For the purposes of compliance with the Cal-OSHA 8 CCR 1532.1 ‘Lead in Construction Standard’, when disturbing any amount of lead, in any material, the employer must ensure their employees are not exposed to lead in excess of the Action Level (AL) or Permissible Exposure Limit (PEL). Contractors must have historical exposure data on file for the task performed or they must conduct an exposure assessment on representative workers. Engineering controls and personal protective equipment (PPE) must be utilized where exposure data dictates. Tasks that are likely to create high lead exposure are abrasive blasting, flame torching, and mechanical grinding. Employers not familiar with the requirements of the Lead in Construction standard can download a brief Cal-OSHA fact sheet by following this link http://www.dir.ca.gov/dosh/dosh_publications/lead-fct-sheet-rev.pdf.

This was a limited survey focusing on specific locations and materials. Other suspect materials may be present in a building of this age. If the scope of work expands, suspect materials must be tested prior to disturbing. This survey should remain onsite for the duration of the project.

If you have any questions please feel free to call us at 831.883.8415

S Tech Consulting

Sean P. Ti l lemaC e r t i f i e d A s b e s t o s C o n s u l t a n t ( C A C ) # 0 7 - 4 2 5 7

C e r t i f i e d L e a d I n s p e c t o r / R i s k A s s e s s o r # 1 6 4 6

Page 10: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

Limited Asbestos & Lead-Based Paint Assessment - 1070 Emeline Avenue, Santa Cruz, California

484

-b washington street m

onterey, ca 93940 #

401 / p 831 883 84

15 / f 877 984 54

95 / [email protected]

/ stechconsulting.com

Limitations

This report is not intended to identify all hazards or unsafe conditions or to imply that others do not exist. This survey was planned and implemented on the basis of a mutually agreed scope of work and S Tech’s experience in performing this type of assessment.

Areas outside our scope or inaccessible areas are excluded from this report. This was not a survey of the entire facility.

S Tech Consulting has performed this survey in a professional manner using the degree of skill and care exercised for similar projects under similar conditions, by reputable and competent environmental consultants. S Tech Consulting shall not be responsible for conditions or consequences arising from relevant facts that were concealed, withheld, or not fully disclosed at the time that this survey was conducted.

S Tech Consulting further states that no warranties, expressed or implied, are made regarding the quality, fitness, or results to be achieved as a consequence of this report or impacted by information not properly disclosed to S Tech at the time of this report. It further states that no responsibility is assumed for the control or correction of conditions or practices existing at the premises of the client.

Page 11: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u

Limited Asbestos & Lead-Based Paint Assessment - 1070 Emeline Avenue, Santa Cruz, California

484

-b washington street m

onterey, ca 93940 #

401 / p 831 883 84

15 / f 877 984 54

95 / [email protected]

/ stechconsulting.com

L a b o r a t o r y A n a l y t i c a l R e p o r t s

Page 12: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u
Page 13: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u
Page 14: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u
Page 15: 1070 EMELINE SIDING AND WINDOW REPLACEMENT PROJECT … II_Project 16C1-010... · 2017-06-27 · e t s o q u e l g r a h a m h i l l r d h w y 9 e m e l i n e site s a n t a c r u