20
100GEL PACKAGE ASPECTS UPDATE Richard Melitz Samtec Liav Ben Artsi Marvell Israel Ltd. 1 IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force

100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

  • Upload
    others

  • View
    8

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

100GEL PACKAGE ASPECTS UPDATE

Richard Melitz – Samtec

Liav Ben Artsi – Marvell Israel Ltd.

1IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force

Page 2: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Table of Contents

• High radix package models

• Field solved 30 mm high radix package

• Matching to a COM package model

• Next steps and discussions

2IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force

Page 3: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Comments

• PTH (plated through hole) on a thick core package seems

inductive

• Coreless small packages not evaluated

• There seem to be 3 package cases for channel

compliance

• High radix packages with a long trace route

• High radix packages with a short trace route

• Low radix packages coreless packages

3IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force

Page 4: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Package Model Extractions

• 30mm PKG trace was design and extracted using HFSS

• Trace width ≈ 30µ

• Dielectric Loss Coefficient = 0.0049 @ 10GHz (Room Temp)

• Next generation surface roughness treatment

• 30mm PKG trace with PTH @ mid of trace resulted in

reflection within the compensation tap region

• Reflection was bigger, but due to location better COM

• May want to decide on exact location after definition of reference

receiver topology

• 8mm model was supplied with higher Xtalk – For

extraction of sigma Xtalk noise - WIP

4IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force

Page 5: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Synthetic 30mm Package Model Extraction

5IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force

Page 6: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Synthetic 30mm Package Model Extraction

• Loss amount resulted in an amount close to 5dB @

26.6GHz (aligned with prediction)

• No Manufacturing tolerance

• No temperature related extra loss

6IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force

Page 7: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 7

IEEE802.3 cd COM package model

Zc=95 W, Zp=[12,30] mm Rd=50 W

Cd=180 fF Cp=110 fF

TP0

Zc=95 W, Zp=[12,30] mm Rd=50 W

Cd=180 fF Cp=110 fF

REFERENCE

Page 8: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Matching to extracted packages model

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 8

TP0

Zc=87.5 W, Zp=[29.5] mm

Rd=

50 W

Cd=100 fF = 90 die + 10 bump Cp=80 fF

Zc=110 W,

Zp=1.8 mm

Zc=87.5 W, Zp=[29.5] mm

Rd=

50 WCd=100fF = 90 die + 10 bump Cp=80 fF

Zc=110 W,

Zp=1.8 mm

Page 9: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

New Transmission Line Parameters

9IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force

Page 10: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Matching 100GEL RefPkg 30mm lowSR

TDR into package without die load

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 10

100GEL RefPkg 30mm lowSR: TDR22

100GEL Synthesized Model TDR22

Page 11: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

PTDR and ERL match is good

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 11

100GEL RefPkg 30mm lowSR: PTDR22 ERL=18 dB

100GEL Synthesized Model PTDR22 ERL=17.7 dB

Page 12: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Pulse Response (6 ps edge)

Compares Well

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 12

Page 13: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

IL compare

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 13

Page 14: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

PTH moves to middle of package

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 14

PTH

PTH

Page 15: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Match for the mid PTH model

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 15

TP0Zc =87.5 W,

Zp=15.5 mm

Cd= 10 fF Cp = 70 fF

Zc1 =87.5 W,

Zp1=7.5 mmZc2 =87.5 W,

Zp2=7 mm

Cv= 5 fF

Zpc =110 W,

Zpp=1.8 mm

Top layer

routing

Crankshaft

vias

Bump

CapacitanceBGA ball Attach

Capacitance

PTHBottom layer

routing

Page 16: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Pulse response compare ( 6 ps edge)

(30 mm mid route PTH

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 16

Page 17: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

IL compare

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 17

Page 18: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Die load (120 ff) pulse response and ISI taps

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 18

Package ISI spans 20-24 UI

Package impacts required Rx capability

What the questions?

Page 19: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

8 mm package has between SNDR

between 43 dB and 51 dB

IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force 19

Test fixture not included

Page 20: 100GEL Package Aspects Update - IEEEgrouper.ieee.org/groups/802/3/ck/public/adhoc/aug15_18/mellitz_3ck_adhoc_03_081518.pdfIEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces

Suggested Next Steps and Discussion

• To Pass COM, Recommend lowering Cdie (Cd) in COM to ~100fF – Discussion

• Discuss possible PTH discontinuity again once Rx topology is decided

• Evaluate the impact of Manufacturing tolerance and temperature discuss whether should be modeled or included in the COM margin

• More work on extracted dense PKG crosstalk – Simulate impact

• Should SNDR_Tx be matched to short vs long package routing? - Discussion

• Are new COM package model(s) required? – Discussion

• All this suggests there is an expectation for the Rx reference model

20IEEE 802.3 100 Gb/s, 200 Gb/s, and 400 Gb/s Electrical Interfaces Task Force