Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
1001m_092309.dgn 9/28/2009 2:04:30 PM
1005mcr_100609.dgn 10/7/2009 10:42:34 AM
1009m_092309.dgn 9/28/2009 2:07:00 PM
1011m_092309.dgn 9/28/2009 2:07:55 PM
1012mcr_100609.dgn 10/7/2009 10:41:20 AM
1013mfinal3_092209.dgn 9/28/2009 2:09:47 PM
1014m_092309.dgn 9/28/2009 2:10:34 PM
1015m_092309.dgn 9/28/2009 2:11:20 PM
1016m_092309.dgn 9/28/2009 2:12:10 PM
1023m_092309.dgn 9/28/2009 2:13:01 PM
1027m_092309.dgn 9/28/2009 2:14:19 PM
1028m_092309.dgn 9/28/2009 2:15:46 PM
1029m_092309.dgn 9/28/2009 2:16:49 PM
1030m_092309.dgn 9/28/2009 2:18:18 PM
1031m_092309.dgn 9/28/2009 2:19:12 PM
1032m_092309.dgn 9/28/2009 2:20:04 PM
1033mcr_100609.dgn 10/7/2009 10:40:10 AM
1035mcr_100609.dgn 10/7/2009 10:39:06 AM
1036mcr_100609.dgn 10/7/2009 10:37:55 AM
1037m_092309.dgn 9/28/2009 2:24:40 PM
1038m_092209.dgn 9/28/2009 2:25:52 PM
1039m_092209.dgn 9/28/2009 2:27:51 PM
1041m_092309.dgn 9/30/2009 2:31:32 PM
1045m_092309.dgn 9/28/2009 2:30:05 PM
1049m_092309.dgn 9/28/2009 2:32:26 PM
1050m_092309.dgn 9/28/2009 2:33:32 PM
ELECTRICAL SERVICE POLE
(SEE NOTE #2)
60A 240/120V, 3-WIRE,
10, 60 hz SERVICE
DROP BY UTILITY COMPANY
ELECTRICAL SERVICE POLE
(SEE NOTE #2)
60A 240/120V, 3-WIRE,
10, 60 hz SERVICE
DROP BY UTILITY COMPANY
OUTDOOR 60A, 240/120V, 3-WIRE, 1 O
LOADCENTER WITH 60 A MAIN BUSWAY
AND COMPLETE WITH 2 - 30 A CIRCUIT BREAKERS
AND 1 - No. 3 MASTER LOCK PADLOCK AND KEY #3210
TRAFFIC SIGNAL AND STREET LIGHTING POLES
16 mm X 2.4 m COPPER
CLAD GROUND ROD
1. OVERHEAD RUNS OF POWER CONDUCTORS AND SIGNAL CONDUCTORS FROM A
PROPOSED OR EXISTING POWER POLE, DIRECT TO THE METAL TRAFFIC SIGNAL POLE,
SHALL NOT BE PERMITTED.
OUTDOOR 60A, 240/120V, 3-WIRE, 1 O
LOADCENTER WITH 60 A MAIN BUSWAY
AND COMPLETE WITH 1 - 30 A CIRCUIT BREAKER
AND 1 - No. 3 MASTER LOCK PADLOCK AND KEY #3210
6 AWG SOLIDLY GROUNDED
WIRE IN 21 mm METALLIC CONDUIT
(SEE NOTE #3)
6 AWG SOLIDLY GROUNDED
WIRE IN 21 mm METALLIC CONDUIT
(SEE NOTE #3)
1.8
m M
IN
.
NEC GROUND CONNECTION
1.8
m M
IN
.
1.8
m M
IN
.
1.8
m M
IN
.
51
0 m
m
NEC GROUND CONNECTION
16 mm X 2.4 m COPPER
CLAD GROUND ROD
1 - 120 VOLT POWER SERVICE IN 27 mm GRC AS FOLLOWS:
2 - 6 AWG INSULATED AND 1 - 6 AWG STRANDED,
BARE COPPER GROUND FOR THE SIGNAL CONTROLLER
51
0 m
m
2 - 120 VOLT POWER SERVICES, EACH IN 27 mm GRC AS FOLLOWS:
2 - 8 AWG INSULATED AND 1 - 8 AWG STRANDED,
BARE COPPER GROUND FOR THE LUMINAIRES;
2 - 6 AWG INSULATED AND 1 - 6 AWG STRANDED,
BARE COPPER GROUND FOR THE SIGNAL CONTROLLER
3. IF METALLIC CONDUIT IS USED FOR GROUNDING. THE CONDUIT MUST BE BONDED
AT THE EXIT END OF THE CONDUIT. BONDING METHOD SHALL CONFORM TO
THE REQUIREMENTS OF THE NEC.
POWER SOURCE FOR COMBINATION 08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
GROUND LINE
NOTES
SERVICE ENTRANCE FITTING
POWER SOURCE DETAILS FOR SIGNALS
SERVICE ENTRANCE FITTING
GROUND LINE
ABBREVIATIONS
AWG - AMERICAN WIRE GUAGE
1
POWER SOURCE DETAIL FOR TRAFFIC SIGNALS
AND TRAFFIC SIGNAL POLES WITH LIGHTING
hz - HERTZ
V - VOLTS
GRC - GALVANIZED RIGID CONDUIT
3 - 6 AWG IN 27 mm CONDUIT
3 - 6 AWG IN 27 mm GRC
1055
A - AMPERE
O - PHASE
2. WOOD POLE SHALL BE CLASS III 10.7 m SOUTHERN PINE CONFORMING TO THE REQUIREMENTS OF
SECTION 890.07(b).
MIN - MINIMUM
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
ROADWAY
SURFACE
TRI-STUD HANGER ASSEMBLY
W/BALANCE ADJUSTER AND
TRI-STUD WIRE OUTLET BODY
(SEE NOTE #8)
THE CONTRACTOR SHALL FURNISH THE POWER SOURCE AND COMPLETE ALL WIRING CONNECTIONS TO
THE LUMINAIRES.
THE CONTACTOR SHALL DETERMINE THE EXACT LOCATION OF THE SPAN CLAMPS AND COUPLINGS TO PROVIDE FOR THE
DESIRED SIGNAL HEIGHT. SPAN WIRE SAG SHALL BE LIMITED TO 5% OF THE LENGTH OF THE SPAN.
BALANCE ADJUSTERS SHALL ONLY BE USED AS DIRECTED BY THE PLANS OR THE ENGINEER.
BACKPLATES, WHEN SO REQUIRED AS SHOWN ON THE PLANS, SHALL HAVE A 127 mm BORDER CONSTRUCTED
OF BLACK METAL.
AND INSTALLATION DETAILS
SHALL PRODUCE AN ASYMMETRICAL LIGHT PATTERN. BALLAST SHALL BE A CONSTANT WATTAGE
AUTO REGULATED (CWA) TYPE. A CLEAR HPS LAMP OF PROPER WATTAGE SHALL BE PROVIDED.
LOUVERS ARE TO BE INSTALLED ONLY IF DIRECTED FOR BY THE PLANS AND SHALL BE ORIENTED SO THAT THE
SIGNAL INDICATION IS ONLY VISSIBLE BY THE APPROACH LANE IT CONTROLS.
LASHED TO MESSENGER
2.4 m MIN. TO 3.6 m MAX
(CENTER-TO-CENTER)
IN ALL CASES, TRAFFIC SIGNAL HEADS SHALL BE LOCATED BETWEEN 5.2 m AND 6.0 m ABOVE THE
ROADWAY SURFACE.
14.3 m POLE, 15.2 m OVERALL MOUNTING HEIGHT SHALL INCLUDE A
11.3 m POLE, 12.2 m OVERALL MOUNTING HEIGHT SHALL INCLUDE A
BACKPLATE (SEE NOTE
#4 & NOTE #9)
THE SIGNAL CONDUCTOR SHALL BE LASHED TO THE MESSENGER WIRE AT 450 mm MAX., CENTER-TO-CENTER WITH 405 mm MIN.
LENGTH X 6.4 mm WIDE X 1.3 mm THICK LASHING RIBBON.
ALTERNATIVE METHODS FOR MOUNTED TRAFFIC SIGNALS OR PEDESTRIAN SIGNALS MAY BE SUBMITTED FOR REVIEW
AND CONSIDERATION BY THE ENGINEER.
FOUNDATION AND FOOTING DETAILS SHALL BE SUBMITTED AND PRE-APPROVED BY THE ENGINEER.
CLAMP (FEED THROUGH DEADEND)
AUTOMATIC COMPRESSION TYPE
(SEE NOTE #10)
SPLIT CLAMP
STEEL CAP WITH
3 SCREWS MINIMUM
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
DRIP LOOP
SIGNAL CONTROL CABLE
9 mm MESSENGER WIRE
SE
E P
LA
NS
FO
R P
OL
E L
EG
NT
H
GROUND LINE
HAND HOLE
WITH COVER
6 mm TETHER WIRE
NOTES
1.
3.
4.
5.
6.
7.
8.
9.
2.
LUMINAIRE
10.
2
METAL TRAFFIC SIGNAL POLE, LIGHTING,
(SHEET 1 OF 2)
REQUIRED:
400-WATT SODIUM VAPOR LUMINAIRE.
250-WATT SODIUM VAPOR LUMINAIRE.
ARM ATTACHMENT DETAIL TO THE POLE UPRIGHT. IN ADDITION THE LUMINAIRE ARM
INDICATES THE ARM WILL SUPPORT THE LOAD REQUIRED BY THE SPECIFICATIONS.
13. THE LUMINAIRE SHALL BE A VERTICAL-LAMP ROADWAY TYPE CONSISTING OF A PRISMATIC
BOROSILICATE GLASS REFRACTOR, DIE CAST ALUMINUM HOUSING WITH CORROSION-RESISANT
11. THE FOLLOWING LAMP SIZE SHALL BE PROVIDED FOR THE POLE MOUNTING HEIGHT
HARDWARE AND SHALL BE WEATHER-TIGHT AND GASKETED; OR A MEDIUM CUT-OFF PATTERN COBRA
ABBREVIATIONS
MIN - MINIMUM
MAX - MAXIMUM
DEAD END CLAMPS ARE REQUIRED FOR EACH POLE.
THIMBLE FOR EYEBOLT
(SIZE AS REQUIRED)
8 mm COPPERCLAD DEADEND
7-STRAND 9 mm UTILITY
MESSENGER CABLE
DEADEND (TYPICAL)
SIGNAL CABLE
PHOTO ELECTRIC CELL
1056
12. THE CONTRACTOR SHALL SUBMIT DETAIL DRAWINGS THAT INDICATE THE LUMINAIRE
WALL THICKNESS, TYPE OF METAL AND SUFFICIENT DATA SHALL BE FURNISHED THAT
PHOTOELECTRIC CONTROLLER AS PER EEI-NEMA REQUIREMENTS. THE OPTICAL ASSEMBLY
14. EXTENDER SHALL BE USED TO GIVE CLEARANCE BETWEEN THE BACKPLATES AND THE
TETHER WIRE.
LASHING RIBBON
(SEE NOTE #3)
SIGNAL HEADS
DRIP LOOP
WEATHER HEAD
STRANDED VICE
HAND HOLE
BREAKAWAY TYPE "S" HOOK
WITH COVER
64 mm COUPLING
HEAD LUMINAIRE. HOUSING SHALL INCLUDE A TWIST-TO-LOCK RECEPTACLE COMPLETE WITH A
BREAKAWAY TETHER
ASSEMBLY
5.2
m M
IN
.
(S
EE
NO
TE
#7)
m - METER
mm - MILLIMETER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
STAINLESS STEEL
CARRIAGE BOLT
GROUNDING CONDUCTORS
LIGHTING ARRESTOR
2 # 8 AWG INSULATED
AND 1 # 8 AWG STRANDED
BARE CIRCUT CONDUCTORS
METAL TRAFFIC SIGNAL POLE, LIGHTING,
AND INSTALLATION DETAILS
(SIZE AND NUMBER
AS SHOWN ON PLANS)
2 # 10 AWG STRANDED
CABLE TO LUMINAIRE
SPAN WIRE CLAMP
LUMINAIRE ARM
(AS REQUIRED IN THE PLANS)
100 mm - 200 mm HAND HOLE
WITH METAL COVER
(2) 6 mm DIAMETER HOLES
FOR 5 mm X 51 mm COTTER PINS
1. THE LENS SHALL BE FABRICATED FROM 3 mm, P4 PATTERNED,
CLEAR LEXAN WITH THE LEGEND APPLIED TO THE INSIDE SURFACE. THE LENS IS MOUNTED
WITHIN THE ALUMINUM ANGLE FRAME AND HELD IN PLACE WITH ALUMINUM CLIPS. AN INSIDE
MOUNTED, FLAT BLACK, PLASTIC LOUVER PANEL SHALL BE PROVIDED TO IMPROVE BLANKOUT
CHARACTERISTICS WHEN NOT ILLUMINATED. THE PANEL SHALL BE CLIP MOUNTED AND EASILY
REMOVED FOR LAMP REPLACEMENT. AN EXTERIOR, FLAT BLACK, ALUMINUM SHADE SCREEN
SHALL BE PROVIDED TO FULLY COVER THE FACE OF THE SIGN AND MOUNTED TO THE
HINGED LENS FRAME.
2. THE SIGN CASE SHALL BE FABRICATED FROM ALUMINUM WITH HINGED DOOR
FRAME FOR EASE IN MAINTENANCE. THE ENTIRE CASE SHALL BE PRIMED WITH CHROMATE
PRIMER AND FINISHED ON THE OUTSIDE WITH TWO (2) COATS OF HIGHWAY YELLOW
AND ON THE INSIDE WITH TWO (2) COATS OF NON -YELLOWING, WHITE, BAKED ENAMEL. THE CASE
SHALL BE SO MANUFACTURED THAT IT CAN EITHER BE MOUNTED ON TOP OR SIDE OF POLE
OR HUNG FROM A SPAN WIRE; ALL USING STANDARD TRAFFIC SIGNAL HARDWARE. FLUORESCENT
LAMPS SHALL BE SPACED APPROXIMATELY ON 76 mm CENTERS AND SHALL BE EITHER 610 mm OR 914 mm
IN LENGTH AS IT PERTAINS TO THE SIGN CASE DIMENSIONS AND SHALL BE T12-CW/HD TYPE. THE
BALLAST SHALL BE 800 MA AND A SUFFICIENT QUANTITY TO IGNITE THE LAMPS IN THE SIGN.
THERE SHALL BE A MINIMUM OF EIGHT (8) FLUORESCENT LAMPS PER SIGN. SOCKETS SHALL BE
THE BY-PIN, TOMBSTONE TYPE, SUITABLE FOR OUTDOOR INSTALLATION. WIRING SHALL BE
ENCASED IN ALUMINUM WIRE WAYS AND THE NECESSARY LEAD SHALL TERMINATE IN A TERMINAL
BLOCK INSTALLED INSIDE THE SIGNS. EACH SIGN SHALL BE EQUIPPED WITH TWO (2) 38 mm HUBS
MOUNTED ON THE TOP OF THE SIGN.
6 AWG SOLID GROUND WIRE
TO 0.16 m x 2.4 m
COPPERCLAD GROUND ROD
* NOTE: SCHEDULE 80 STEEL
BREAK-A-WAY FUSE HOLDER
SINGLE-POLE U.L. RECOGNIZED
10 mm X 38 mm FUSE.
30A 600V
#12 AWG - #2 AWG
2 PER TERMINAL COPPER
COPPER SET SCREW
08-2009 Revisions To This
Sheet
75 mm x 125 mm HAND HOLE
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
38 mm THREADED COUPLING
BY POLE MANUFACTURER
LENGTH AS REQUIRED
90^ ELBOW
LOCK NUTS
POLE
GROUNDING LUG
APPROACH LANE
AP
PR
OA
CH
LA
NE
APPROACH LANE
AP
PR
OA
CH
LA
NE
STEEL CLAMP
LIGHTING ARRESTOR DETAIL
2A
(SHEET 2 OF 2)
NON-METALLIC CONDUIT
LOCK WASHERS
WITH HEX NUTS AND
SPAN WIRE CLAMP
ABBREVIATIONS
RIGHT
NO
TURN
BLANKOUT MESSAGE SIGN
TRAFFIC SIGNAL SIDE MOUNT
AWG - AMERICAN WIRE GUAGE
MA - MILLIAMPS
LUMINAIRE ORIENTATION SCHEMATIC
J HOOK
J HOOK
305 mm
38 mm5 mm X 76 mm
16 mm DIAMETER "U" BOLT
762 mm
914 m
m
1057
NOTES
SPECIFICATIONS FOR ILLUMINATED SIGNAL FACE BLANK OUT MESSAGE SIGN
CONSTRUCTION:
LENS AND BLANK OUT PANELS:
*
TEXT MAY BE EITHER
"RIGHT" OR "LEFT"
*
VARIES
SIGNAL HEAD ASSEMBLY
GALVANIZED
150 PSI GALV.
STEEL
GALV - GALVINIZED
mm - MILLIMETER
STEEL PIPE
A - AMPERE
V - VOLTS
m - METER
* THREADED PIPE
* THREADED NIPPLE
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
NOTE: REFER TO APPROVED POLE
DRAWINGS FOR SIZE, NUMBER
AND BOLT CIRCLE DIAMETER
OF ANCHOR BOLTS.
STEEL TEMPLATE FOR
ANCHOR BOLT ALIGNMENT
NOTE: REFER TO APPROVED POLE
DRAWINGS FOR SIZE, NUMBER
AND BOLT CIRCLE DIAMETER
OF ANCHOR BOLTS.
STEEL TEMPLATE FOR
ANCHOR BOLT ALIGNMENT
NOTE: REFER TO APPROVED POLE
DRAWINGS FOR SIZE, NUMBER
AND BOLT CIRCLE DIAMETER
OF ANCHOR BOLTS.
STEEL TEMPLATE FOR
ANCHOR BOLT ALIGNMENT
NOTE: REFER TO APPROVED POLE
DRAWINGS FOR SIZE, NUMBER
AND BOLT CIRCLE DIAMETER
OF ANCHOR BOLTS.
STEEL TEMPLATE FOR
ANCHOR BOLT ALIGNMENT
* NOTE: FOR ANCHOR BOLT PROTECTION
REFER TO APPROVED
POLE DRAWINGS
TEMPORARY TEMPLATE
FOR ANCHOR BOLT ALIGNMENT
COPPER CLAD
GROUND ROD
6 AWG SOLID BARE
COPPER WIRE
TIES: 13 mm BARS
AT 305 mm O.C.
TIES: 13 mm BARS
AT 305 mm O.C.
TIES: 13 mm BARS
AT 305 mm O.C.
TIES: 13 mm BARS
AT 305 mm O.C.
TIES: 13 mm BARS
AT 300 mm O.C.
510 mm
Min
imum
Overl
ap
510 mm
Min
imum
Overl
ap
510 mm
Min
imum
Overl
ap
510 mm
Min
imum
Overl
ap
PERMANENT STEEL TEMPLATE
FOR ANCHOR BOLT
ALIGNMENT (SEE NOTE 3)
GROUND ROD
CLAMP
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
ANCHOR BOLT ASSEMBLY
*
TOP NUT
FLAT WASHER
FLAT WASHER
LEVELING NUTPOLE BASE PLATE
ELEVATION VIEW
ANCHOR BOLT NUT AND BOLT DETAIL
GROUNDING FOR METAL TRAFFIC SIGNAL POLE
CO
NC
RE
TE
FO
UN
DA
TIO
N
AS REQUIRED
NOTES
4
TRAFFIC SIGNAL POLE FOUNDATION
ABBREVIATIONS
6. CONDUIT NUMBER AND SIZE AS REQUIRED BY THE PLANS.
AWG - AMERICAN WIRE GUAGE
GROUND LINE
21 mm METALLIC CONDUIT
10 - 25 mm BARS
76 mm
14 - 28 mm BARS
76 mm
14 - 25 mm BARS
900 mm - 0 mm DIAMETER FOUNDATION PLAN VIEW
76 mm
900 mm - 0 mm
1200 mm - 0 mm
1200 mm - 0 mm DIAMETER FOUNDATION PLAN VIEW
76 mm
20 - 28 mm BARS
75 m
m
105 m
m M
ax.
75 m
m
75 m
m -
150 m
m
16 mm X 2.4 m
750 mm1100 mm
750 mm DIAMETER FOUNDATION PLAN VIEW 1100 mm DIAMETER FOUNDATION PLAN VIEW
1059
3 m
eters B
AS
IC
150 m
m O
.C.
1. CONCRETE SHALL BE CLASS A TYPE 2A WITH A MINIMUM 28-DAY STRENGTH OF 20 MPa.
2. ANCHOR BOLT ASSEMBILES SHALL BE INSTALLED IN ACCORDANCE WITH THE APPROVED
TRAFFIC SIGNAL FOUNDATION SHOP DRAWINGS.
3. PERMANENT STEEL TEMPLATES SHALL BE FROM 3 mm STEEL PLATE RING. ANCHOR BOLT
HOLES SHALL BE OVERSIZED BY 3 mm AND SHALL HAVE A 6 mm CLEARANCE
TO BOTH OUTSIDE AND INSIDE EDGES OF THE RING.
4. CONDUITS REQUIRED IN CONCRETE FOUNDATIONS SHALL BE ACCURATELY PLACED, ORIENTED
IN THE PROPER DIRECTION TO ACCOMMODATE FUTURE EXTENSION AND SECURLY HELD
IN PLACE TO AVOID MOVEMENT. ALL CONDUITS SHALL BE INSTALLED IN ACCORDANCE
WITH SECTION 730 AND STANDARD DRAWINGS.
5. MINIMUM DEPTH OF FOUNDATION SHALL BE 3 meters AS BID, UNLESS A
LESSER DEPTH IS APPROVED BY THE ENGINEER.
mm - MILLIMETER
MAX - MAXIMUM
O.C. - ON CENTER
m - METER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
64 mm DIAMETER GALVANIZED
STEEL COUPLING TO ACCEPT
WEATHERHEAD.
(EXIT FOR INTERNAL WIRING)
CLASS A TYPE 2 CONCRETE FOUNDATION
1. THE CONTRACTOR SHALL DETERMINE THE EXACT LOCATION OF THE SPAN WIRE CLAMPS AND COUPLINGS TO PROVIDE
FOR THE DESIRED SIGNAL HEIGHT AND SHALL TIGHTEN THE SIGNAL SPAN WIRE TO ACHIEVE MAXIMUM 5% SAG OF THE
SPAN WIRE BETWEEN POLES.
3. SEE TSD-730-2 AND TSD-730-2A FOR TRAFFIC SIGNAL AND LIGHTING DETAIL.
100 mm X 300 mm
HAND-HOLE WITH
150 mm
MIN.
150 mm
MIN.
2. 10.7 m POLE VARIES 0.08 m TO 1 m
3.6 meter ARM
25 mm DIAMETER THRU-BOLT
TO ACCEPT EYE-BOLT
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
08-2009 Revisions To This
Sheet
*
NO
TE
*S
EE
AS
RE
QU
IRE
D
NOTES
CONCRETE POLE
VA
RIE
S
CONCRETE WALL
PRESTRESSING
THICKNESS VARIES
GROUNDING
CROSS SECTION OF PRESTRESSED, SPUN, CONCRETE POLE
INSIDE
(VOID)
DIAMETER
GROUND LINE
SPUN CONCRETE TRAFFIC SIGNAL POLE
CONCRETE POLE
GROUND LINE
TANK GROUND
SPUN CONCRETE TRAFFIC SIGNAL POLE
5
13.7 m POLE VARIES 2.8 m TO 3.7 m
18.3 m POLE VARIES 5.9 m TO 6.8 m
ABBREVIATIONS
MIN. - MINIMUM
TANK GROUND PLACEMENT WITH GROUND WIRE IN CONCRETE POLE
4 AWG STRANDED COPPER WIRE
UNLESS OTHERWISE SHOWN IN PLANS
AWG - AMERICAN WIRE GUAGE
APPROX - APPROXIMATELY
AP
PR
OX
. 6
10
mm NEC GROUND CONNECTION
4 AWG SOLID BARE COPPER WIRE
O.D. VARIES
O.D. - OUTSIDE DIAMETER
150 mm - 300 mm
150 mm - 300 mm
10.7 m POLE = 2.1 m EMBEDMENT
13.7 m POLE = 2.4 m EMBEDMENT
18.3 m POLE = 3.9 m EMBEDMENT
1060
EDGE OF ROADWAY
ORIENTED 180^ FROM
COVER
GROUND WIRE
16 mm X 2400 mm - 0 mm COPPERCLAD GROUND ROD
STRAND
WIRE 4 AWG
m - METER
mm - MILLIMETER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
CONTROLLER (SEE PLANS
FOR LOCATIONS)
FEED-THROUGH DEAD
END STRANDVISE
HIGH STRENGTH ANCHOR
WOODEN TRAFFIC SIGNAL POLE DETAILS
HIGH STRENGTH ANCHOR
AP
PR
OX
IMA
TE
LY
45 D
EG
RE
ES
2. IF DOWN GUYS ARE ALLOWABLE, CONCRETE
FOUNDATIONS ARE NOT REQUIRED.
STANDARD CLAMP
END FITTING ON
53 mm GALV. PIPE
1.5 m - 2.7 m
600 mm MIN.
1500 mm PREFERED
6 AWG - BARE COPPER
SOLID WIRE
GALV.
GUY GUARD
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
SIDEWALK
2.7
m
2.4
m
TO POWER
2.4
m
1.2
m
WOOD POLE
NOTES
1. SIDEWALK GUY INSTALLATION SHALL ONLY BE USED AT LOCATIONS WHERE
THERE IS NOT ADEQUATE AREA FOR THE STANDARD GUY INSTALLATION OR
WHERE THERE ARE SIDEWALKS ON THE PROJECT.
GUY INSTALLATION AT SIDEWALK
6
DISCONNECT SWITCH
GRC CONDUIT STRAPS
ABBREVIATIONS
GRC - GALVANIZED RIGID CONDUIT
AWG - AMERICAN WIRE GUAGE
GUY INSTALLATION
9 mm DIAMETER AT 3153 KG
27 mm GRC CONDUIT
53 mm GRC CONDUIT
152 mm MAX.
3.6 m
16 mm x 2.4 m COPPERCLAD GROUND ROD
1061
MIN - MINIMUM
MAX - MAXIMUM
GALV - GALVINIZED
m - METER
mm - MILLIMETER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
2. 3-14 AWG SHALL BE RUN TO THE FLASHER ASSEMBLY FROM THE CONTROLLER
CABINET WHERE IT SHALL BE TIED INTO THE INTERSECTION CIRCUIT.
3. DIMENSIONS SHOWN SHALL ALSO BE USED FOR THE INSTALLATION
OF OTHER TYPES OF WARNING SIGNS AS SHOWN IN THE PLANS.
6. HANDHOLES FOR PEDESTAL POLES SHALL BE ORIENTED 180 DEGREES
FROM SIGNAL FACE.
SPAN WIRE HANGER
AND WIRE ENTRANCE
FITTING
HAND HOLE
WITH COVER
PEDESTAL POLE WITH MOUNTED FLASHER
(Solar Powered, DC [typical Rural])
PEDESTAL POLE WITH MOUNTED FLASHER
(AC Powered, Controller at Service Pole)
BATTERY & CONTROLL
CABINET BEHIND SIGN.
SIDEWALK or
ROADWAY
SIDEWALK or
ROADWAY
HAND HOLE
WITH COVER
PEDESTAL POLE WITH MOUNTED FLASHER
(Solar Powered, DC [typical Urban])
HAND HOLE
WITH COVER
1. CONTROLLER SHALL HAVE A SOLID STATE FLASHER COMPLETE WITH JACK
PANEL, FIVE (5) POINT FEED THROUGH TERMINAL BLOCK FOR FIELD
CONNECTIONS AND A 15-AMP CIRCUIT BREAKER. POWER SUPPLY SHALL BE
PROTECTED BY A SURGE ARRESTOR. THE CABINET SHALL BE FABRICATED
FROM SHEET OR CAST ALUMINUM AND HAVE A RAIN-TIGHT ENTRANCE HUB.
CABINET SHALL HAVE A STANDARD LOCK WITH TWO (2) KEYS. ALL POLE
MOUNTING HARDWARE SHALL BE SUPPLIED. CABINET SIZE SHALL BE
APPROXIMATELY 168 mm X 264 mm X 345 mm. THE CABINET COLOR
SHALL BE ALUMINUM. THE FLASH RATE SHALL BE BETWEEN 50 AND 60
TIMES PER MINUTE.
4. THE MINIMUM HEIGHT FOR ADVISORY SPEED LIMIT SIGNS(W13-1) OR
OTHER SUPPLEMENTAL PLAQUES IN CONJUCTION WITH THE WARNING
SIGNS SHALL BE 1.8 m.
5. THE HORIZONTAL LOCATION OF THESE SIGNS SHALL BE AT THE FOLLOWING MINIMUMS:
RURAL AREAS - SHALL BE A MINIMUM OF 3.6 m FROM THE EDGE OF
PAVEMENT OR 1.8 m FROM PAVED SHOULDER, WHICH EVER IS GREATER.
URBAN AREAS - SHALL BE A MINIMUM OF 0.61 m FROM THE FRONT
EDGE OR CURB.
1.2 m FROM THE LINE OF THE REAR OF THE POST, IF PROTECTED BY GUARDRAIL.
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
ABBREVIATIONS
NOTES
MIN. - MINIMUM
AERIAL MOUNTED FLASHING BEACON
SIGNAL CABLE
AWG - AMERICAN WIRE GUAGE
STEEL
SEE TSD 730-9A
ELEVATION VIEW
HEAD WITH AMBER GLASS LENS
GROUND LINEPOLE IS SET AND PLUMB
ELEVATION VIEW
GROUND LINE
POLE IS SET AND PLUMB
ELEVATION VIEW
HEAD WITH AMBER LED LENS
HEAD WITH AMBER LED LENS
VARIES
80 WATT SOLAR PANEL
80 WATT SOLAR PANEL
GROUND LINE
ADVANCE WARNING AT INTERSECTIONS
300 mm -2 SECTION SIGNAL
230 mmTYPICAL 1200 mm WARNING SIGN
102 mm SPUN ALUMINUM POLE
2.1 m MIN.
100 mm MIN. GROUT AFTER
300 mm -2 SECTION SIGNAL
230 mmTYPICAL 1200 mm WARNING SIGN
2.1 m MIN. 102 mm SPUN ALUMINUM POLE
100 mm MIN. GROUT AFTER
9 mm MESSENGER CABLE
300 mm -2 SECTION SIGNAL
TYPICAL 1200 mm WARNING SIGN
230 mm
102 mm SPUN ALUMINUM POLE
2.1 m MIN.
100 mm MIN. GROUT AFTER
2.1 m MIN.
7 1062
AMP - AMPERE
SEE TSD 730-9A
SEE TSD 730-9A
POLE IS SET AND PLUMBED
2 SECTION SIGNAL HEAD, TYPICAL
300 mm GLASS SIGNAL LENS, TYPICAL
STEEL MOUNTING PLATE
m - METER
mm - MILLIMETER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
INTERSECTION AND ADVANCED
SCHOOL WARNING FLASHER DETAIL
SIDEWALK
OR ROADWAY
(OPTIONAL SIGN CONFIGURATION)
S4-3
R2-1
S4-4
SIDEWALK
OR ROADWAY
(OPTIONAL SIGN CONFIGURATION)
S4-3
R2-1
S4-4
1. CONTROLLER SHALL HAVE A SOLID STATE FLASHER COMPLETE WITH
JACK PANEL, FIVE (5) POINT FEED THROUGH TERMINAL BLOCK FOR FIELD
CONNECTIONS AND A 15-AMP CIRCUIT BREAKER. THE FLASH RATE SHALL BE
50 TO 60 TIMES PER SECOND. POWER SUPPLY SHALL BE PROTECTED BY A
SURGE ARRESTOR FABRICATED FROM SHEET OR CAST ALUMINUM AND HAVE A
RAINTIGHT ENTRANCE HUB. CABINET SHALL HAVE A STANDARD LOCK WITH TWO
(2) KEYS. CABINET SHALL BE SUPPLIED WITH ALL MOUNTING HARDWARE.
2. 3-14 AWG SHALL BE RUN TO THE FLASHER ASSEMBLY FROM THE CONTROLLER
CABINET WHERE IT WILL BE TIED INTO THE INTERSECTION CIRCUIT.
PEDESTAL POLE WITH MOUNTED FLASHER [RURAL]
PEDESTAL POLE WITH MOUNTED FLASHER [URBAN]
3. HANDHOLES FOR PEDESTAL POLES SHALL BE ORIENTED 180 DEGREES
FROM SIGNAL FACE.
102 mm SPUN ALUMINUM BREAKAWAY
PEDESTAL POLE
102 mm SPUN ALUMINUM BREAKAWAY
PEDESTAL POLE
100 mm MIN. GROUT
AFTER POLE IS SET AND PLUMBED
100 mm MIN. GROUT
AFTER POLE IS SET AND PLUMBED
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
VARIES
SCHOOL
SPEED
LIMIT
25WHEN
FLASHING
SCHOOLSCHOOL
SPEED
LIMIT
25WHEN
FLASHING
HANDHOLE WITH COVER
ELEVATION VIEW
GROUND LINE
2.1
m M
IN
.
SOLAR PANEL (80 WATTS)
BATTERY AND FLASHER CABINET
2.1
m M
IN
.
HEAD WITH AMBER LED LENS
HANDHOLE WITH COVER
ELEVATION VIEW
HEAD WITH AMBER LED LENS
SOLAR PANEL (80 WATTS)
ABBREVIATIONS
MIN - MINIMUM
NOTES
8
AWG - AMERICAN WIRE GUAGE
300 mm -2 SECTION SIGNAL
S5-1, 1200 mm SIGN
230 mm
S5-1, 1200 mm SIGN
230 mm
300 mm -2 SECTION SIGNAL
1063
AMP - AMPERES
m - METER
mm - MILLIMETERS
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
PUSH
BUTTON
FOR
PUSH
BUTTON
FOR
PUSH BUTTON
PROVIDE BUSHING IN POLE
FOR MOUNTING PUSH BUTTON
HANDHOLE WITH COVER
TRAFFIC SIGNAL POLE
MOUNTED PEDESTRIAN SIGNAL
1. HANDHOLES FOR PEDESTAL POLES SHALL BE ORIENTED 180 DEGREES
FROM SIGNAL FACE.
230 mm x 300 mm
R10-4B SIGN ATTACH WITH
STAINLESS STEEL BANDS
102 mm SPUN ALUMINUM
BREAKAWAY PEDESTAL POLE
100 mm MIN. GROUT AFTER
POLE IS SET AND PLUMBED
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
GROUND LINE
PLAN VIEW
R10-4B
R10-4B
9
NOTES
PEDESTRIAN SIGNAL INSTALLATION
1064
ABBREVIATIONS
MIN - MINIMUM
PEDESTAL MOUNTED PEDESTRIAN SIGNAL ASSEMBLY
mm - MILLIMETER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
COPPERCLAD
GROUND ROD
6 AWG SOLID BARE
COPPER WIRE
DOOR OPENING
WELD CONNECTION
OPTIONAL DOORS FOR PEDESTAL BASES
HANDLE WITH COVER
BOLT COVER
INTERNAL PIPE THREADS
DOOR OPENING
APPROXIMATELY 127 mm X 279 mm APPROXIMATELY 203 mm X 203 mm
08-2009 Revision To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
9A 1065
PEDESTAL FOUNDATION AND BASES
GROUND LINE
19 mm NONMETALLIC CONDUIT
NONMETALLIC CONDUIT
CLASS A TYPE 2
CONCRETE FOUNDATION
ANCHOR BOLT (TYPICAL)
1500 m
m
ELEVATION VIEW
PLAN VIEW
FULL BASE
COVER
(2 PIECE)
31 m
m -
150 m
m
FOOTING FOR PEDESTAL POLE
51 mm
13 mm HOOPS ON
310 mm CENTERS
50 mm MIN.
16 mm X 2.4 m
8 - 13 mm STEEL BARS
PLACED AFTER POLE
100 mm MINIMUM GROUT
IS SET AND PLUMBED
PEDESTAL POLE FOUNDATION DETAIL
ABBREVIATIONS
MIN - MINIMUM
AWG - AMERICAN WIRE GUAGE
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
mm - MILLIMETER
m - METER
STAINLESS STEEL
UNIVERSAL CLAMP
POLE MOUNTED CONTROLLER
2. WHEN MODIFYING AN EXISTING CONTROLLER PAD FOR A NEW CABINET,
IF ONE OR MORE OF THE EXISITING ANCHOR BOLTS CAN BE RE-UESD,
DO NOT CUT THEM OFF.
3. CABINET DOOR SHALL BE ORIENTED SO WHEN THE CABINET
DOOR IS OPEN THE TRAFFIC SIGNALS ARE VISIBLE TO THE TECHNICIAN.
CONTROLLER
CABINET
ALABAMA DEPARTMENT OF
TRANSPORTATION
CONDUIT NUMBER AND SIZE AS
SHOWN ON THE PLANS
EXISTING PAD
GROUT WITH
NON-SHRINKING GROUT
CONDUIT NUMBER AND SIZE
AS REQUIRED BY THE PLANS
5. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO INSTALL
BASE MOUNTED CONTROL CABINET’S PAD, AND ONE SPARE CONDUIT
FOR FUTURE USE. THE COST SHALL BE INCLUDED IN PAY ITEM 730R.
6. THE CONTROLLER CABINET SHALL BE INSTALLED ON TOP OF SILICONE RUBBER CAULKING COMPOUND.
7. GROUND LINE SHALL BE AT FINISHED GRADE.
SEE TSD-730-4
FOR FOUNDATION DETAILS
27 mm METALLIC CONDUIT
FROM POWER SOURCE
78 mm I.D. GALV. CONDUIT
90 DEGREE PULL
OUTLET 78 mm I.D.
4. CABINET SHALL BE DESIGNED SO NO EQUIPMENT WILL BE MOUNTED WITHIN
152 mm FROM THE TOP OF THE CABINET.
1. ON COMPLETION OF THE INSTALLATION, WIRING IN CONDUIT IN THE CONTROLLER
CABINET AND ALL EXPOSED CONDUIT OPENINGS SHALL BE SEALED WITH A SILICONE
COMPOUND.
SEE MANUFACTURE’S TEMPLATE
FOR ANCHOR BOLT LAYOUT
CAULK AROUND BASE OF CONTROLLER
(SEE NOTE #7)
19 mm STAINLESS STEEL
BANDS WITH ANTI-ROTATIONAL
BUCKLESTRAP
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
GROUND LINE
CONTROLLER CABINET
POLE MOUNTED
VARIES
NOTES
ABBREVIATIONS
I.D. - INSIDE DIAMETER
GALV. - GALVINIZED
50
8 m
m
CO
NT
RO
LL
ER
CA
BIN
ET
VA
RIE
S
VARIES
VARIES
WELDED REINFORCING WIRE
REQUIRED PAD EXTENSION
ANCHORS
CAULK BASE OF CABINET
50
8 m
m
CONTROL CABINET GROUND BUS
CONDUIT AS REQUIRED BY THE PLANS
10
BASE AND POLE MOUNTED CONTROLLER
CABINET INSTALLATIONS
CABINET
O.C. - ON CENTER
CLASS A TYPE 2 CONCRETE
16 mm X 2.4 m COPPERCLAD GROUND ROD
FRONT VIEW
CONTROLLER PAD AND CABINET
SIDE VIEW
CONTROLLER PAD AND CABINET
TOP VIEW
CONTROLLER PAD AND CABINET
CLASS A TYPE 2 CONCRETE
MODIFIED EXISTING CONTROLLER PAD FOR NEW CABINET MOUNTING
13 mm DOWEL BAR 300 mm O.C.
150 mm
150 mm
600 mm
150 mm 150 mm
15
0 m
m
200 mm
100 mm
150 mm 150 mm
30
0 m
m
76
2 m
m
25
4 m
m
1066
16 mm X 2.4 m COPPERCLAD GROUND ROD
DOOR
MIN
COUPLING
1.5 m MIN, TYPICAL
MIN
MIN - MINIMUM
m - METER
mm - MILLIMETER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
LENGTH AS SHOWN
IN THE PLANS
LENGTH AS SHOWN
IN THE PLANS
6. A SUBMERSSIBLE HEAT SHRINK TUBING OR RE-ENTERABLE SILICONE GEL CONTAINED IN AN
ENCLOSURE THAT WHEN SNAPPED SHUT PROVIDES A SUBMERSSIBLE CONNECTION SHALL BE
USED IN UNDERGROUND SPLICES.
7. QUADRUPOLE LOOPS ARE REQUIRED FOR LEFT TURNS, WHEN LEFT TURN SIGNAL HEAD
IS REQUIRED ON THE TRAFFIC SIGNAL LAYOUT SHEET.
TO
JUNCTION
BOX
4. SLOT SHALL BE FILLED WITH SEALANT IN ACCORDANCE WITH MANUFACTURER’S RECOMMENDATIONS.
LOOP IN ASPHALT
C - C
LOOP IN CONCRETE
C - C
LOOP LEAD-IN
CONCRETE OR ASPHALT
B - B
LOOP IN CONCRETE
OR ASPHALT
A - A
FLEXIBLE LIQUIDTIGHT
OR PVC CONDUIT
FLEXIBLE LIQUIDTIGHT
OR PVC CONDUIT
1.8
m W
ID
TH
1.8
m W
ID
TH
178 mm OVERRUN BASED ON
610 mm DIAMETER SAW BLADE
178 m
m
MA
X.
178 m
m
MA
X.
178 m
m
MA
X.
DETAIL 1
1. A SHARP OBJECT SHALL NOT BE USED TO TAMP LOOP WIRE. THE OBJECT SHALL
BE MADE OF PLASTIC OR WOOD MATERIAL.
2. LOOP WIRE LEAD-IN SHALL BE PROVIDED IN SEPARATE SLOTS OR CONDUIT IN TRENCHES
FOR EACH INDIVIDUAL LOOP.
5. SPLICES BETWEEN THE LOOP FEEDER AND THE HOME-RUN CONDUCTOR SHALL BE
ENCASED IN A SPLICE CONNECTOR KIT.
DETAIL 1
3. LOOP SEALANT SHALL NOT BE INSTALLED WHEN (1) THERE IS ANY MOISTURE ON THE
SURFACE, (2) THE AIR TEMPERATURE IS BELOW 4.4^C, OR (3) OTHER CONDITIONS
THAT IN THE OPINION OF THE ENGINEER WOULD AFFECT THE BONDING OF THE MATERIAL
TO THE SURFACE.
08-2009 Revisions To This
Sheet
DIRECTION
OF TRAFFIC
DIRECTION
OF TRAFFIC
JUNCTION BOX
JUNCTION BOXLOOP DETECTOR
LEAD-IN CABLE
LOOP DETECTOR
LEAD-IN CABLE
FACE OF CURB OR
EDGE OF PAVEMENT
FACE OF CURB OR
EDGE OF PAVEMENT
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
DIMENSIONS OF SAWCUT
DIMENSIONS OF SAWCUT
TURN REQUIREMENTS FOR LOOP
NUMBER OF TURNS
NUMBER OF TURNS
TURN REQUIREMENTS FOR QUADRUPOLE LOOP
2-4-2
3
VARIABLE
FACE OF CURB OR EDGE OF PAVEMENT
FACE OF CURB OR EDGE OF PAVEMENT
NOTES
ABBREVIATIONS
MAX - MAXIMUM
C - CENTIGRADE
MIN - MINIMUM
DETAILS OF LOOP WIRE LAYOUT
PAVEMENT
CONC. CURB OR
CURB & GUTTER
JUNCTION
BOX
LOOP SEALANT
LOOP WIRE
SPLICE CONNECTION
CABLE & CONDUIT
JUNCTION
GROUND LINE
INSTALLATION OF JUNCTION BOX, CONDUIT AND LOOP WIRE
IN CURBED ROADWAYS
PAVEMENT
JUNCTION
BOX
VARIES
LOOP SEALANT
LOOP WIRE
SPLICE CONNECTION
CABLE & CONDUIT
JUNCTION
GROUND LINE
INSTALLATION OF JUNCTION BOX, CONDUIT AND LOOP WIRE
45^ TO 60^ TYPICAL
45^ TO 60^ TYPICAL
VARIES
5 mm TO 8 mm
35
mm
MIN
.
5 mm TO 8 mm 5 mm TO 8 mm 5 mm TO 8 mm
40
mm
MIN
.
35
mm
MIN
.
40
mm
MIN
.
2 m x 2 m TO 2 m x 7 m
2 m x 10 m TO 2 m x 15 m 2
2 m x 10 m TO 2 m x 18 m
508 m
m M
IN
. 51 m
m T
O 7
6 m
m
508 m
m M
IN
.
51 m
m T
O 7
6 m
m
300 m
m
11 1067
LOOP WIRE INSTALLATION
QUADRUPOLE LOOP SAWCUT
LOOP SAWCUT
LEAD-IN
LEAD-IN
(SEE NOTE #5)
(SEE NOTE #5)
VARIES
RECTANGULAR LOOP SAWCUT DETAIL
(SEE NOTE #3)
QUADRUPOLE LOOP
A
A
C
C
PRESENCE LOOP
LOOP DETECTOR WINDING
B B C
C
B B
(SEE NOTE #7)
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
m - METER
mm - MILLIMETER
ALTERNATE CAMERA MOUNTING LOCATION
(WITH OPTIONAL SIDEMOUNT "L" BRACKET)
PREFERRED CAMERA MOUNTING
LOCATION ("I" BRACKET)
CA
ME
RA
HE
IGH
T M
INIM
UM
9.1
m A
BO
VE
TH
E R
OA
DW
AY
OR
AS
RE
CO
MM
EN
DE
D B
Y
TH
E M
AN
UF
AC
TU
RE
R
SECTION A-A
SUNSHIELD
POWER AND
COAX CABLE
DRIP LOOPS
LUMINAIRE ARM
STAINLESS STEEL BANDING
MOUNTING BRACKET
DIAMETER OF TURN ACCORDING
TO COAX MANUFACTURER
NO TWISTS ARE ALLOWED
IN CABLE
3.65 m. MAX. 3.65 m. MAX.
SEE TSD-730-4 FOR SIGNAL
POLE FOUNDATION DETAILS
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
12
VIDEO DETECTION INSTALLATION
VDS CAMERA INSTALLATION
ABBREVIATIONS
VDS - VEHICLE DETECTION SYSTEM
APPROXIMATELY 300 mm FROM LUMINAIRE
300 mm
1068
A
A
WIRE TIE-STRAPS
2 TURNS MAX.
LEFT
TURN
SIGNAL
VDS CAMERA INSTALLATION ON MAST ARM POLES
mm - MILLIMETER
m - METER
2.4 m. MIN. 2.4 m. MIN.
MIN - MINIMUM
MAX - MAXIMUM
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
TRAFFIC SIGNAL CABLE BURIED BELOW
TAPE COLOR - RED, LEGEND COLOR - BLACK
UNTAMPED OR
UNDISTURBED SUB-GRADE
CONDUIT OR DIRECT
BURIAL CONDUCTORS
VARIESMARKING TAPE
BACKFILL
AND TAMP
CONDUIT CONSTRUCTION DETAIL
VARIESMARKING TAPE
FINISHING GRADE
CONDUIT
SATISFACTION OF THE ENGINEER
JUNCTION BOX IN SOIL
ALDOT #57
FINISH GRADE
BACKFILL
AND TAMP
BACKFILL
ONLY
UNTAMPED OR
UNDISTURBED SUB-GRADE
(COST OF ALDOT #57 IS INCLUDED
IN PAY ITEM 730K-000)
CONDUIT CONSTRUCTION DETAIL NOT
EXPOSED TO VEHICLE TRAFFICCONDUIT CONSTRUCTION DETAIL UNDER
EXISTING SIDEWALK OR SLOPE PAVING
CONCRETE TO BE
REMOVED AND REPLACED
(SEE NOTE #2)
TAMPING
LAYER
CONCRETE SLAB
VARIES
08-2009 Revision To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
TR
AFFIC
CO
NTR
OL
VARIES
PULL SLOT
JUNCTION BOX COVER
740 +
/- m
m
1. ALL DIMENSIONS SHOWN ARE APPROXIMATE.
CAUTION CAUTION
DETAIL FOR 4.0 MIL POLYETHYLENE
MARKING TAPE
25 mm
15
2 m
m
C MESSAGEL
15
0 m
m
20
0 m
m
NOTE : BACKFILL WITH SUITABLE PORTION OF EXCAVATED
MATERIAL FROM EXCAVATION OR SELECTED MATERIAL
APPROVED BY THE ENGINEER.
20
0 m
m
NOTE : BACKFILL MATERIAL SHALL BE PLACED WITH SAME
TYPE OF MATERIAL REMOVED AND COMPACTED TO THE
30
0 m
m
76
mm
51
0 m
m
NOTES
min
.
JUNCTION BOX INSTALLATION
51
0 m
m
510 +
/- mm
15
0 m
m
15
0 m
m
60
0 m
m
NOTE: MESSAGE TO BE SPACED 900 mm CENTER TO CENTER
64 mm
38 mm
13 1069
2. CONCRETE SHALL BE REPLACED TO MATCH WHAT WAS REMOVED.
+/- = APPROXIMATE
mm. = MILLIMETER
WITH WASHER
9.5 mm HEX BOLT,
11 mm DRILL FOR
60
0 m
m
BACKFILL AND
TAMP
MIN = MINIMUM
ABBREVIATIONS
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
CURB AND GUTTER
OR CURB
CLASS A TYPE 2
CONCRETE ENCASEMENT
CLASS A TYPE 2
CONCRETE ENCASEMENT
BACKFILLING, RESEEDING OR RESODDING
TO COMPLY WITH APPLICABLE PROVISIONS OF
THE SPECIFICATIONS.
NON-METALLIC, ELECTRICAL CONDUIT
(SEE NOTE #2)
NON-METALLIC, ELECTRICAL CONDUIT
(SEE NOTE #2)
NON-METALLIC, ELECTRICAL CONDUIT
(SEE NOTE #2)
SECTION A - A: TYPE 1 ENCASEMENT
(ONE LINE) - [SEE NOTE #3]
SECTION A - A: TYPE 1 ENCASEMENT
(TWO LINES) - [SEE NOTE #3]
A
A
B
B
TYPE 1 AND TYPE 5
ENCASEMENT DETAILS
PRECISION DIRECTIONAL BORE
UNDER EXISTING PAVEMENT
FRONT SLOPES OF 6:1 TO 4:1 - MIN. DIST. 1.52 m
FRONT SLOPES GREATER THAN 4:1 - MIN. DIST. 0.9 m
600 mm
MIN.
FRONT SLOPES OF 6:1 TO 4:1 - MIN. DIST. 1.52 m
FRONT SLOPES GREATER THAN 4:1 - MIN. DIST. 0.9 m
1. ALL CONDUIT INSIDE ENCASEMENT SHALL BE PAID FOR UNDER
PAY ITEM 756. REFER TO SECTION 756 OF THE CURRENT ALABAMA
DEPARTMENT OF TRANSPORTATION STANDARD SPECIFICATIONS.
2. NUMBER AND SIZE OF CONDUITS AS SHOWN ON PLANS.
3. TYPE, NUMBER OF LINES AND SIZE OF ENCASEMENT AS SHOWN ON PLANS.
4. ENCASEMENT UNDER RAILROAD TRACKS SHALL MEET THE REQUIREMENTS OF THAT RAILROAD.
762 mm PER
SECTION 756.03(d) 762 mm PER
SECTION 756.03(d)
ENCASEMENT PLACED BY PRECISION DIRECTIONAL
BORE UNDER EXISTING PAVEMENT PER SECTION
756.03(d). (SEE NOTES #5 & #6)
5. JACKING AND BORING NOT ALLOWED.
ABBREVIATIONS
MIN. - MINIMUM
08-2009 Revisions To This
Sheet
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
PAVED SHOULDERS
ROADWAY
CONDUCTORS
EDGE OF PAVEMENTROADWAY
TYPE 1 ENCASEMENT INSTALLATION
OPEN TRENCH UNDER NEW PAVEMENT
CLASS A TYPE 2 CONCRETE ENCASEMENT
TYPE 5 ENCASEMENT INSTALLATION
ENCASEMENT CONDUITENCASEMENT CONDUIT
ENCASEMENT CONDUIT
NOTES
14
*
6. UPHEAVEL IN ROADWAY NOT ALLOWED.
75
mm
75
mm
50 mm
* 76 mm ENCASEMENT ON TOP, BOTTOM, AND SIDES
1070
HDPE (HIGH DENSITY POLYETHYLENE)
PER SECTION 756.02 AND AS SHOWN
ON THE PLANS.
SECTION B - B: TYPE 5 ENCASEMENT CONDUIT IN HDPE ENCASEMENT
*
DIST - DISTANCE
m - METER
mm - MILLIMETER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
DEADEND WITH READY
ACCESS CLOSURE
AERIAL HARDWIRE
INTERCONNECT CABLE
MESSENGER HANGER
ASSEMBLYMESSENGER HANGER
ASSEMBLY
CROSSARM BOLT
AND NUT
GALVANIZED SPIRAL
LASHING ROD TYPE
FOR HARDWIRE
INTERCONNECT
MESSENGER HANGER
ASSEMBLY
MESSENGER HANGER
ASSEMBLY
GALVANIZED SPIRAL
LASHING ROD TYPE
FOR HARDWIRE
INTERCONNECT
ADJUSTABLE
POLE CLAMP
CROSSARM NUT
AND BOLT
HARDWARE FOR INTERCONNECT
ATTACHMENT DETAILS
1. CONNECTIONS IN AERIAL ACCESS CLOSURE SHALL BE ACCOMPLISHED
BY IN LINE CONNECTIONS.
3. AERIAL HARDWIRE, INTERCONNECT, TV CABLE, AND TELEPHONE CABLE
SHALL BE ON THE SAME SIDE OF THE POLE.
10
16
mm
MIN
IMU
M
(S
EE
NO
TE
3)
5.2 m
MIN
IMU
M W
ITH
SA
G
2. THE 1016 mm MINIMUM CLEARANCE ALSO APPLIES TO THE CLOSEST METAL
PORTION OF ANY ONE SPOOL, THREE SPOOL, OR FOUR SPOOL.
OVERHEAD CABLE AND
9 mm MESSENGER CABLE
OVERHEAD CABLE AND
9 mm MESSENGER CABLE
600 mm TO
1070 mm
600 mm TO
1070 mm
FISCALYEAR
SHEETNO.
ALABAMA DEPARTMENTOF TRANSPORTATION09-27-97 Varner
(Convert to Cadd)
08-2005 Revisions All
Sheets
TRANSFORMER
GROUND LINE
3 BOLT CLAMP
STRAIGHT THIMBLEYE BOLT
OVERHEAD CABLE
MESSENGER WIRE
WOOD POLE
WOOD POLE
AERIAL DEADEND CONNECTION
HARDWIRE INTERCONNECT
TELEPHONE CABLE
ATTACHMENT TO JOINT USE POWER COMPANY, TELEPHONE COMPANY, AND CATV
FRONT VIEW SIDE VIEW
WOOD POLE
SUSPENSION CLAMP
FRONT VIEW SIDE VIEW
WOOD POLE
SIDE VIEW TOP VIEW
INTERMEDIATE CONNECTION FOR WOOD POLE
MESSENGER WIRE
OVERHEAD CABLE
METAL POLE
SIDE VIEW TOP VIEW
INTERMEDIATE CONNECTION FOR METAL POLE
SIDE VIEW
INTERMEDIATE CONNECTION FOR CONCRETE POLE
CONCRETE POLE
AERIAL HARDWIRE INTERCONNECT
NOTES
15
SIDE VIEW
AERIAL CORNER CONNECTION
AUTOMATIC STRAND VISE
762 m
m M
INIM
UM
300 mm MINIMUM
300 mm MINIMUM
9 mm MESSENGER
16 mm THRU BOLT
9 mm 38 mm
150 mm
3 - 16 mm BOLTS
1071
CABLE
ABBREVIATIONS
m - METER
mm - MILLIMETER
PROJECT NO.
TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
T.S.D. - 730 -
ALABAMA DEPARTMENTOF TRANSPORTATION
(SIZE ACCORDING TO
CONDUIT SIZE)
SHEETSNO.
REFERENCEPROJECT NO.
GALVANIZED U-CHANNEL INSERT
(BY OTHERS)
RECESSED IN BRIDGE CONCRETE
GALVANIZED
U-CHANNEL
FOR MOUNTING
CONDUIT TO
THE BRIDGE
GALVANIZED
CONDUIT
STRAP
GAP
C
CONDUIT
STRAP
GALVANIZED
CLAMP
1. CLAMP, CLAMP BACK, AND NEST
BACK SHALL BE PRODUCTS OF
THE SAME MANUFACTURER.
2. 1525 mm MAXIMUM SPACING FOR
CONDUIT CLAMPS.
BRIDGE
ABUTMENT
TO GROUND MOUNTED
JUNCTION BOX
90-DEGREE PULL FITTING
FOR LIGHTING CONDUCTORS
CONDUIT ATTACHED TO BRIDGE DETAIL
6 mm STAINLESS STEEL HEX HEAD
MACHINE BOLT, FLAT WASHER, LOCK
WASHER, AND HEX NUT.
MASONRY ANCHOR BOLTS (3),
PLATED ALLOY STEEL MATERIAL,
9.5 mm MINIMUM DIAMETER,
WITH PREASSEMBLED EXPANDER
PLUGS.
MASONRY ANCHOR BOLTS (3),
PLATED ALLOY STEEL MATERIAL,
9.5 mm MINIMUM DIAMETER,
WITH PREASSEMBLED EXPANDER
PLUGS.
6 mm STAINLESS STEEL HEX HEAD
MACHINE BOLT, FLAT WASHER, LOCK
WASHER, AND HEX NUT.
WING WALL
METALLIC CONDUIT
NON-METALLIC CONDUIT
WING WALL
METALLIC CONDUIT NON-METALLIC CONDUIT
CORE DRILL
AND GROUT
DETAILS OF CONDUIT THRU WING WALL
METALLIC CONDUIT CONDULET
MIN
.
MIN
.
BRIDGE DECK
METALLIC CONDUIT
JOINTS ON SIMPLE SPAN BRIDGES
N.T.S.
MOUNTING
STRAP
CONCRETE BRIDGE
NON-METALLIC CONDUIT
GROUND LINE
CONCRETE BRIDGE
BRIDGE ABUTMENT
ROAD SURFACE
SLOPE PAVING
CLAMP BACK
CONDUIT
NEST BACK
PIPE STRAP
CONDUIT
CLAMP BACK
NEST BACK
INSTALLATION WITH INSERT PROVIDED
(SIZE ACCORDING TO CONDUIT SIZE)
METALLIC CONDUIT TENNESSEE
FLORIDA
Gulf ofMexico
GE
OR
GIA
MIS
SIS
SIP
PI
DEPA
RTMENT OF TRANSP
ORTA
TIO
N
ALABAMA
OF TRANSPORTATION REPRESENTATIVE AUTHORIZED TO APPROVE THIS USE. ANYONE MAKING
UNAUTHORIZED USE OF THIS DRAWING MAY BE PROSECUTED TO THE FULLEST EXTENT OF THE LAW.
DESIGN BUREAU SPECIAL DRAWING
1409 COLISEUM BOULEVARD
MONTGOMERY, AL 36130-3050
THIS DRAWING REPRESENTS DESIGNS PREPARED FOR USE BY THE ALABAMA DEPARTMENT OF
ANY ORGANIZATION, WITHOUT THE EXPRESSED WRITTEN CONSENT OF THE ALABAMA DEPARTMENT
TRANSPORTATION AND IS NOT TO BE COPIED, REPRODUCED, ALTERED, OR USED BY ANYONE, OR
REVISIONS
CURRENT ALABAMA DEPARTMENT OF TRANSPORTATION
--SPECIFICATIONS--
DRAWN BY:
DATE DRAWN:
SPECIAL DRAWING NO. INDEX NO.
(GALVANIZED )
(GALVANIZED )
CLAMPING SPRING NUT
(SIZE ACCORDING TO CONDUIT SIZE)
CLAMPING SPRING NUT
METALLIC CONDUIT
INSTALLATION ON SLOPE PAVING AND BRIDGE ABUTMENTS
FISCALYEAR
INSTALLATION OF CONDUIT UNDER EDGE OF BRIDGE
GALVANIZED CLAMPING SPRING NUT
GALVANIZED
EDGE OF BRIDGE
INSTALLATION WITH SURFACE-MOUNTED GALVANIZED U-CHANNEL EDGE OF BRIDGE
L
A
A
WING WALL
FRONT VIEW
METALLIC CONDUIT
SLOPE PAVING
GALVANIZEDCLAMP
DETAIL SHOWING METHOD OF CONDUIT CROSSING AT EXPANSION
T.S.D. - 730 -16 1072
SECTION A-A
LIQUIDTIGHT FLEXIBLE METALLIC CONDUIT
456 mm 456 mm
76-mm MAXIMUM SAG
610 mm
610 m
m
610 m
m
30
5 m
m
MIN. - MINIMUM
mm - MILLIMETER
ABBREVIATIONS
Revisions To This
Sheet
08-2009
1085_RL-LPF-001_M_ Brkaway Lum Pole Fnd.dgn 10/1/2009 10:54:40 AM
1085A_RL-LPF-002_M_HiMast & Non Brkaway Lumin Pole Fnd.dgn 10/1/2009 10:55:59 AM
1086_RL-LPF-003_M_Lum Pole Found w Brkawy Cplgs.dgn 10/1/2009 10:57:21 AM
1087_RL-LPF-004_M_Hi Mast and NB Pole Dtls.dgn 10/1/2009 10:58:23 AM
1088_RL-LPF-005_M_Concr Pad Dtls For Brkawy Lum Poles.dgn 10/1/2009 10:59:22 AM
1089_RL-LPF-006_M_Elect. Wiring For NB Lum Poles.dgn 10/1/2009 11:00:52 AM
1089A_RL-LPF-007_M_Elect. Wiring For Brkawy Lum Poles.dgn 10/1/2009 11:02:03 AM
1090_RL-LPF-008_M_Hi Mast Lgtning Prot Dtls.dgn 10/1/2009 11:03:01 AM
1091_RL-LPF-009_M_Lgtning Prot 75' or Grtr Poles w ILD.dgn 10/1/2009 11:05:14 AM
1092_RLD-001_M_Conduit-Bridge.dgn 10/1/2009 11:07:31 AM
1093_RLD-002_M_Type WP Svc_Metric_Sht. 1 of 2.dgn 10/1/2009 11:08:31 AM
1094_RLD-004_M_Type DE Svc_Metric_Sht. 1 of 2.dgn 10/1/2009 11:09:56 AM
1094A_RLD-005_M_Type DE Svc_Metric_Sht. 2 of 2.dgn 10/1/2009 11:11:09 AM
1095_RLD-006_M_Type 1 & 2 Elect Jct Box.dgn 10/1/2009 11:12:17 AM
1096_RLD-007_M_Type 3 Elect Jct Box.dgn 10/1/2009 11:13:14 AM
1097_RLD-008_M_Conduit Under RdwyMET.dgn 10/1/2009 11:14:28 AM
1098_RLD-009_M_Elec Grnd Non-Brkaway Pole Fnd.dgn 10/1/2009 11:15:28 AM
1098A_RLD-010_M_Elec Grounding Brkaway Pole Fnd.dgn 10/1/2009 11:16:30 AM
1099_RLD-011_M_O'head Service to Type WP LCC.dgn 10/1/2009 11:19:57 AM
1099A_RLD-012_M_O'head Service to Type DE LCC.dgn 10/1/2009 11:21:17 AM