Repair MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M) The existing Level Two security fence at the MACS-2 Tactical Compound does not currently meet Level Two Restricted Area requirements as required by MCO 5530.14A. The existing fence currently has the following deficiencies: (1) The fence does not meet the overall fence height requirement of 8’-0” (fabric height of 7’-0” plus a top guard of three strands of #12 barbed wire facing outward at a 45 degree angle) (2) Portions of the fence have a damaged or missing top guard (3) Maximum allowable clearance below the fence are exceeded in many areas (4) Interior and exterior clear zones around the fence are in violation in several areas (combined clear zone is 33 feet, interior clear zone minimum is 20 feet and exterior clear zone minimum is 10 feet) (5) Gates exceed the maximum clearance requirements. (6) There is insufficient Restricted Area signage on the fence. Forty-Three existing light poles and the associated lighting circuits both in and outside the MACS-2 Level Two Area are in poor condition and shall be replaced. All but six of the existing light fixtures on the existing poles are new and are to be reused. The remaining six light fixtures shall be replaced. The scope of work for this project is: (1) Replace the existing Level 2 fence with a new 8’-0” (fabric height of 7’-0” plus a top guard of three strands of barbed wire facing outward at a 45 degree angle) Level 2 Restricted Area fence. The existing fence shall be completely removed. The new fence shall be furnished and installed to meet the requirements of MCO 5530.14A, UFC 4-022-03, Security Fences and Gates and the requirements of this RFP; including but not limited to all clearances and restricted area signage. The new fence shall include two lockable vehicle gates spanning the entire roadway width and two lockable personnel gates. For convenience, example Level 2 Restricted Area fence details are provided as well as a copy of the MCO 5530.14A, and a copy of UFC 4-022-03, Security Fences and Gates. Clear the exterior perimeter of the new Level 2 fence out 10’-0” from the fence utilizing a type GyroTrack machine. See Figure 1. (2) Replace forty-three each light poles both in and outside the Level 2 Area with new 35 foot Class 3 yellow pine penta-treated poles with pole caps. On thirty seven of the poles the existing light fixtures are to be saved and reused on the new poles. On six of the poles, new light fixtures to match those of adjacent fixtures are to be installed. For pricing purposes assume that new poles will not be installed at the exact same location as existing poles. See figure 2. (3) Replace the existing electrical lighting circuit(s) that feed the light poles both in and outside the Level 2 Area with new buried circuit(s) in new conduit. Provide 1” SCH 40 PVC underground conduit to each new pole at a minimum depth of two

1.0 PROJECT DESCRIPTION - Civil Works Contracting MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M)

  • Upload
    vantu

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1.0 PROJECT DESCRIPTION - Civil Works Contracting MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M)

Repair MACS-2 Secure Area; MCAS Beaufort, SC BE1804M

PART 3 - CHAPTER 1 - Page 1

1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M) The existing Level Two security fence at the MACS-2 Tactical Compound does not currently meet Level Two Restricted Area requirements as required by MCO 5530.14A. The existing fence currently has the following deficiencies: (1) The fence does not meet the overall fence height requirement of 8’-0” (fabric height of 7’-0” plus a top guard of three strands of #12 barbed wire facing outward at a 45 degree angle) (2) Portions of the fence have a damaged or missing top guard (3) Maximum allowable clearance below the fence are exceeded in many areas (4) Interior and exterior clear zones around the fence are in violation in several areas (combined clear zone is 33 feet, interior clear zone minimum is 20 feet and exterior clear zone minimum is 10 feet) (5) Gates exceed the maximum clearance requirements. (6) There is insufficient Restricted Area signage on the fence. Forty-Three existing light poles and the associated lighting circuits both in and outside the MACS-2 Level Two Area are in poor condition and shall be replaced. All but six of the existing light fixtures on the existing poles are new and are to be reused. The remaining six light fixtures shall be replaced. The scope of work for this project is:

(1) Replace the existing Level 2 fence with a new 8’-0” (fabric height of 7’-0” plus a top guard of three strands of barbed wire facing outward at a 45 degree angle) Level 2 Restricted Area fence. The existing fence shall be completely removed. The new fence shall be furnished and installed to meet the requirements of MCO 5530.14A, UFC 4-022-03, Security Fences and Gates and the requirements of this RFP; including but not limited to all clearances and restricted area signage. The new fence shall include two lockable vehicle gates spanning the entire roadway width and two lockable personnel gates. For convenience, example Level 2 Restricted Area fence details are provided as well as a copy of the MCO 5530.14A, and a copy of UFC 4-022-03, Security Fences and Gates. Clear the exterior perimeter of the new Level 2 fence out 10’-0” from the fence utilizing a type GyroTrack machine. See Figure 1.

(2) Replace forty-three each light poles both in and outside the Level 2 Area with new 35 foot Class 3 yellow pine penta-treated poles with pole caps. On thirty seven of the poles the existing light fixtures are to be saved and reused on the new poles. On six of the poles, new light fixtures to match those of adjacent fixtures are to be installed. For pricing purposes assume that new poles will not be installed at the exact same location as existing poles. See figure 2.

(3) Replace the existing electrical lighting circuit(s) that feed the light poles both in and outside the Level 2 Area with new buried circuit(s) in new conduit. Provide 1” SCH 40 PVC underground conduit to each new pole at a minimum depth of two

Page 2: 1.0 PROJECT DESCRIPTION - Civil Works Contracting MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M)

Repair MACS-2 Secure Area; MCAS Beaufort, SC BE1804M

PART 3 - CHAPTER 1 - Page 2

feet. Provide 1” rigid conduit above grade to a new NEMA 4X stainless steel junction box mounted two feet above grade on each pole. Provide ¾” rigid conduit up the poles and a ¾” weather head. Provide three #8 thhn wires for power and one #10 thhn wire for the ground to each fixture on each pole. There are four existing poles that have recently been replaced that are fed from the existing circuit that is being replaced in this RFP. In the case of these poles, the pole and the light fixture are to remain. Demolish existing power and provide new power to these light fixtures as outlined above. See Figure 3.

(4) Replace the existing electrical lighting circuit(s) that feed the light poles at Facility 1028 inside the Level 2 Area with new buried circuit(s) in new conduit. Provide 1” SCH 40 PVC underground conduit to each new pole at a minimum depth of two feet. Provide 1” rigid conduit above grade to a new NEMA 4X stainless steel junction box mounted two feet above grade on each pole. Provide ¾” rigid conduit up the poles and a ¾” weather head. Provide three #8 thhn wires for power and one #10 thhn wire for the ground to each fixture on each pole. See Figure 4.

(5) Replace the existing electrical lighting circuit(s) that feed the light poles at the Parking Lot outside the Level 2 Area with new buried circuit(s) in new conduit. Provide 1” SCH 40 PVC underground conduit to each new pole at a minimum depth of two feet. Provide 1” rigid conduit above grade to a new NEMA 4X stainless steel junction box mounted two feet above grade on each pole. Provide ¾” rigid conduit up the poles and a ¾” weather head. Provide three #8 thhn wires for power and one #10 thhn wire for the ground to each fixture on each pole. Leave the overhead circuits conductors on poles 1526B and on pole 1524 and go underground circuits from pole 1526B and pole 1524. See Figure 5.

Page 3: 1.0 PROJECT DESCRIPTION - Civil Works Contracting MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M)

GEIGER

MACS TWO

CORPO RAL

RADAR RD

982

W NCO

E NCO

WASH RACK

AIR CO NTRO L

LO G CABIN

STARBASE

E NICO

1064

1171660

662

661

12361068

1242

1011

2088

1094

1028

987

1067

1236A

1212

1035

1184

1182

1011T

1098

1181

2000

1093

SPHER OID . . . . . . . . . . . . . . . . . . . . . GEODETIC R EFER ENCE SYSTEM 1980PR OJECTION . . . . . . . . . . . . . . . . . . UNIVER SAL TR ANSVER SE MER CATORVER TICAL DATUM . . . . . . NOR TH AMER ICAN VER TICAL DATUM 1988HOR IZONTAL DATUM . . . . . . . . . . . . . . . . NOR TH AMER ICAN DATUM 1983CONTR OLLED BY . . . . . . . . USGS, NATIONAL GEODETIC SUR VEY POINTSGR ID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 - METER UTM ZONE 18GR ATICULE . . . . . . . . . . . . . . . . HALF MINUTE LATITUDE-LONGITUDE TICS

Map g en erated u sing th e Geog raph ic Inform ation SystemManag ed b y th e In stallation Geospatial Inform ation & Services Offic e

R eg io nal Geospatial Inform ation & Servic es Division, GF,Marine Corps Installations East – M arine Corps Base Cam p Lejeu ne

FOR R EFER ENCE ONLYFOR OFFICIAL USE ONLY (FOUO)

NOT TO BE USED FOR TAR GETING OR NAVIGATION

Disc laim er:Alth ou g h every effort h as b een m ade to ensu re th e ac c u rac y of in form atio n,errors and c onditio ns orig inating from th e ph ysic al sou rc es u sed to develop th edatab ase m ay b e reflec ted in th e data su pplied. Th e requ estor m u st b e awareof data c o nditions and u ltim ately b ear respon sib ility for th e appropriate u se

of th e info rm ation with respec t to possib le errors, orig in al m ap sc ale, co llec tio n m eth odo lo g y, cu rren cy o f data, and oth er spec ific c onditions to c ertain data.Th is inform ation does not depic t all possib le resou rc es. Field verification of all data is req u ired for site-spec ific projec ts. Th is inform ation is deem ed

reliab le, b u t not g u aranteed.

FIGURE 1

Le g e ndLevel 2 Fence To Be R eplacedExisiting FenceStru c tu reAreaBuildingSite

1 inch = 300 fe e t

0 110 220 330 440Feet

0 60 120 180 240Yards

1:3,605Scale

IGI&S MCAS Be au fortBLD 616 Rm 125Rand Th acke r843.228.6702

CO NTACT INFO RMATIO N

O u r Mission is to Provide pre cise and re liable g e o spatial inform ation and m anag e d IT/GIS se rvice s to e nable visu alization and u s e by

MCIEAST and Installations, and oth e rcom m ands as approve d by CG MCIEAST–CAMLEJ, to m e e t th e installation m anag e m e n

t m ission and th e broade r ne e ds of th e Marine Corps.

µ

LEVEL 2 AREA

Page 4: 1.0 PROJECT DESCRIPTION - Civil Works Contracting MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M)

B

B

B

RR

RR

R

R

R

R

R

R

R

RR

R

R

R

RR

R

R

R

R

RR

R

R

R

R

R

RR

R

R

R

R

R

R

B

B

B

GEIGER

MACS TWO

CORPO RAL

RADAR RD

982

W NCO

E NCO

WASH RACK

AIR CO NTRO L

LO G CABIN

STARBASE

E NICO

1171660

662

661

1242

1064

1011

2088

1094

1236

1028

987

1236A

1212

1035

1184

1011T

1098

2000

1093

SP HEROID . . . . . . . . . . . . . . . . . . . . . GEODETIC REFERENCE SYSTEM 1980P ROJECTION . . . . . . . . . . . . . . . . . . UNIVERSAL TRANSVERSE MERCATORVERTICAL DATUM . . . . . . NORTH AMERICAN VERTICAL DATUM 1988HORIZONTAL DATUM . . . . . . . . . . . . . . . . NORTH AMERICAN DATUM 1983CONTROLLED BY . . . . . . . . USGS, NATIONAL GEODETIC SURVEY P OINTSGRID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 - METER UTM ZONE 18GRATICULE . . . . . . . . . . . . . . . . HALF MINUTE LATITUDE-LONGITUDE TICS

Ma p g e n e ra te d using th e Ge og ra p h ic Inform a tion Syst e mMa na g e d b y th e In sta lla tion Ge ospa tia l Inform a tion & Se rvice s Office

Re g iona l Ge ospa t ia l Inform a tion & Se rvice s Division, GF,Ma rine Corps Insta lla tions Ea st – M a rine Corps Ba se Ca m p Le je une

FOR REFERENCE ONLYFOR OFFICIAL USE ONLY (FOUO)

NOT TO BE USED FOR TARGETING OR NAVIGATION

Discla im e r:Alth oug h e ve ry e ffort h a s b e e n m a de to e nsure th e a ccura cy of in form a tion,e rrors a nd condit ions orig ina ting from th e ph ysica l source s use d to de ve lop th eda ta b a s e m a y b e re fle cte d in th e da ta supplie d. Th e re que stor m ust b e a wa reof da ta conditions a nd ultim a te ly b e a r re spon sib ility for th e a p propria te use

of th e inform a tion with re spe ct to possib le e rrors, orig in a l m a p sca le , colle ction m e th odolog y, curre n cy of da ta , a nd oth e r spe cific conditions t o ce rta in da ta .Th is inform a tion doe s not de p ict a ll p ossib le re source s. Fie ld ve rifica tion of a ll da ta is re quire d for site -spe cific proje cts. Th is inform a tion is de e m e d

re lia b le , b ut not g ua ra nte e d.

FIGURE 2

Legend

B P rovide Ne w P ole / Ne w Lig h t

R P rovide Ne w P ole / Existing Lig h t

Le ve l 2 Fe nce To Be Re pla ce dExisiting Fe nceStructure Are aBuildingSite

1 inch = 300 feet

0 110 220 330 440Fe e t

0 60 120 180 240Ya rds

1:3,605Scale

IGI&S MCAS BeaufortBLD 616 Rm 125Rand Th acker843.228.6702

CO NTACT INFO RMATIO N

O ur Mission is to Prov ide precise and reliable geospatial in fo rm ation and m anaged IT/GIS serv ices to enable v isualization and use by

MCIEAST and Installations, and oth ercom m ands as appro v ed by CG MCIEAST–CAMLEJ, to m eet th e installation m anagem en

t m issio n and th e broader needs of th e Marine Corps.

µ

Page 5: 1.0 PROJECT DESCRIPTION - Civil Works Contracting MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M)

!!

!!

RR

R

R

R

R

R

R

R

RR

R

R

R

R

R

R

R

R

R

RR

R

R

R

R

R

RR

R

R

B

)T

GEIGER

MACS TWO

CORPO RAL

RADAR RD

982

W NCO

E NCO

WASH RACK

AIR CO NTRO L

LO G CABIN

STARBASE

E NICO

1171660

662

661

1242

1064

1011

2088

1094

1236

1028

987

1236A

1212

1035

1184

1011T

1098

2000

1093

SP HEROID . . . . . . . . . . . . . . . . . . . . . GEODETIC REFERENCE SYSTEM 1980P ROJECTION . . . . . . . . . . . . . . . . . . UNIVERSAL TRANSVERSE MERCATORVERTICAL DATUM . . . . . . NORTH AMERICAN VERTICAL DATUM 1988HORIZONTAL DATUM . . . . . . . . . . . . . . . . NORTH AMERICAN DATUM 1983CONTROLLED BY . . . . . . . . USGS, NATIONAL GEODETIC SURVEY P OINTSGRID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 - METER UTM ZONE 18GRATICULE . . . . . . . . . . . . . . . . HALF MINUTE LATITUDE-LONGITUDE TICS

Ma p g e ne ra te d us ing the Ge og ra phic Inform a tion Syste mMa na g e d by the Ins ta lla tion Ge os pa tia l Inform a tion & Se rvice s Office

Re g io na l Ge os pa tia l Inform a tion & Se rvice s Divis ion, GF,Ma rine Corps Ins ta lla tions Ea s t – M a rine Corps Ba s e Ca m p Le je une

FOR REFERENCE ONLYFOR OFFICIAL USE ONLY (FOUO)

NOT TO BE USED FOR TARGETING OR NAVIGATION

Dis cla im e r:Althoug h e ve ry e ffort ha s be e n m a d e to e ns ure th e a ccura cy of inform a tio n,e rrors a nd cond itio ns orig ina ting from the phys ica l s ource s us e d to d e ve lop thed a ta ba s e m a y be re fle cte d in th e d a ta s upplie d . Th e re que s tor m us t be a wa reof d a ta co nd itions a nd ultim a te ly be a r re s pons ibility for the a ppropria te us e

of the info rm a tion with re s pe ct to pos s ible e rrors , orig ina l m a p s ca le , co lle ctio n m e thod o lo g y, curre ncy o f d a ta , a nd othe r s pe cific cond itions to ce rta in d a ta .This inform a tion d oe s not d e pict a ll pos s ible re s ource s . Fie ld ve rifica tion of a ll d a ta is re q uire d for s ite -s pe cific proje cts . This inform a tion is d e e m e d

re lia ble , but not g ua ra nte e d .

FIGURE 3

LegendR Ne w P ole / Existing Lig ht

B Ne w P ole / Ne w Lig ht

! Existing P ole / Existing Lig ht

) Trans form e r W he re Circuit Org ina te s

Le ve l 2 Fe nce To Be Re pla ce dExis iting FenceStructure Are aBuild ingSite

1 inch = 300 feet

0 110 220 330 440Fe e t

0 60 120 180 240Ya rd s

1:3,605Scale

IGI&S MCAS BeaufortBLD 616 Rm 125Rand Th acker843.228.6702

CO NTACT INFO RMATIO N

O ur Mission is to Prov ide precise and reliable geospatial in fo rm ation and m anaged IT/GIS serv ices to enable v isualization and use by

MCIEAST and Installations, and oth ercom m ands as appro v ed by CG MCIEAST–CAMLEJ, to m eet th e installation m anagem en

t m issio n and th e broader needs of th e Marine Corps.

µ

Page 6: 1.0 PROJECT DESCRIPTION - Civil Works Contracting MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M)

R

R BB

GEIGER

MACS TWO

CORPO RAL

RADAR RD

982

W NCO

E NCO

WASH RACK

AIR CO NTRO L

LO G CABIN

STARBASE

E NICO

1171

660

662

661

1242

1064

1011

2088

1094

1236

1028

987

1236A

1212

1035

1184

1011T

1182

1098

1179

2000

1093

SP HEROID . . . . . . . . . . . . . . . . . . . . . GEODETIC REFERENCE SYSTEM 1980P ROJECTION . . . . . . . . . . . . . . . . . . UNIVERSAL TRANSVERSE MERCATORVERTICAL DATUM . . . . . . NORTH AMERICAN VERTICAL DATUM 1988HORIZONTAL DATUM . . . . . . . . . . . . . . . . NORTH AMERICAN DATUM 1983CONTROLLED BY . . . . . . . . USGS, NATIONAL GEODETIC SURVEY P OINTSGRID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 - METER UTM ZONE 18GRATICULE . . . . . . . . . . . . . . . . HALF MINUTE LATITUDE-LONGITUDE TICS

Ma p g e ne ra te d us ing the Ge og ra phic Inform a tion Syste mMa na g e d by the Ins ta lla tion Ge os pa tia l Inform a tion & Se rvice s Office

Re g io na l Ge os pa tia l Inform a tion & Se rvice s Divis ion, GF,Ma rine Corps Ins ta lla tions Ea s t – M a rine Corps Ba s e Ca m p Le je une

FOR REFERENCE ONLYFOR OFFICIAL USE ONLY (FOUO)

NOT TO BE USED FOR TARGETING OR NAVIGATION

Dis cla im e r:Althoug h e ve ry e ffort ha s be e n m a d e to e ns ure th e a ccura cy of inform a tio n,e rrors a nd cond itio ns orig ina ting from the phys ica l s ource s us e d to d e ve lop thed a ta ba s e m a y be re fle cte d in th e d a ta s upplie d . Th e re que s tor m us t be a wa reof d a ta co nd itions a nd ultim a te ly be a r re s pons ibility for the a ppropria te us e

of the info rm a tion with re s pe ct to pos s ible e rrors , orig ina l m a p s ca le , co lle ctio n m e thod o lo g y, curre ncy o f d a ta , a nd othe r s pe cific cond itions to ce rta in d a ta .This inform a tion d oe s not d e pict a ll pos s ible re s ource s . Fie ld ve rifica tion of a ll d a ta is re q uire d for s ite -s pe cific proje cts . This inform a tion is d e e m e d

re lia ble , but not g ua ra nte e d .

FIGURE 4

1 inch = 300 feet

0 110 220 330 440Fe e t

0 60 120 180 240Ya rd s

1:3,605Scale

IGI&S MCAS BeaufortBLD 616 Rm 125Rand Th acker843.228.6702

CO NTACT INFO RMATIO N

O ur Mission is to Prov ide precise and reliable geospatial in fo rm ation and m anaged IT/GIS serv ices to enable v isualization and use by

MCIEAST and Installations, and oth ercom m ands as appro v ed by CG MCIEAST–CAMLEJ, to m eet th e installation m anagem en

t m issio n and th e broader needs of th e Marine Corps.

µ

LegendB Ne w P ole / Ne w Lig ht

R Ne w P ole / Exis ting Lig ht

Le ve l 2 Fe nce To Be Re place dExis iting Fe nceStructure Are aBuild ingSite

Loca tion W he reCirtcuit Org ina te s1028

Page 7: 1.0 PROJECT DESCRIPTION - Civil Works Contracting MACS-2 Secure Area; MCAS Beaufort, SC BE1804M PART 3 - CHAPTER 1 - Page 1 1.0 PROJECT DESCRIPTION Repair MACS-2 Secure Area (BE1804M)

R

RR

R

RB

GEIGER

MACS TWO

CORPO RAL

RADAR RD

982

W NCO

E NCO

WASH RACK

AIR CO NTRO L

LO G CABIN

STARBASE

E NICO

1171660

662

661

1242

1064

1011

2088

1094

1236

1028

987

1236A

1212

1035

1184

1011T

1098

2000

1093

SP HEROID . . . . . . . . . . . . . . . . . . . . . GEODETIC REFERENCE SYSTEM 1980P ROJECTION . . . . . . . . . . . . . . . . . . UNIVERSAL TRANSVERSE MERCATORVERTICAL DATUM . . . . . . NORTH AMERICAN VERTICAL DATUM 1988HORIZONTAL DATUM . . . . . . . . . . . . . . . . NORTH AMERICAN DATUM 1983CONTROLLED BY . . . . . . . . USGS, NATIONAL GEODETIC SURVEY P OINTSGRID . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1000 - METER UTM ZONE 18GRATICULE . . . . . . . . . . . . . . . . HALF MINUTE LATITUDE-LONGITUDE TICS

Ma p g e n e ra te d using th e Ge og ra p h ic Inform a tion Syst e mMa na g e d b y th e In sta lla tion Ge ospa tia l Inform a tion & Se rvice s Office

Re g iona l Ge ospa t ia l Inform a tion & Se rvice s Division, GF,Ma rine Corps Insta lla tions Ea st – M a rine Corps Ba se Ca m p Le je une

FOR REFERENCE ONLYFOR OFFICIAL USE ONLY (FOUO)

NOT TO BE USED FOR TARGETING OR NAVIGATION

Discla im e r:Alth oug h e ve ry e ffort h a s b e e n m a de to e nsure th e a ccura cy of in form a tion,

e rrors a nd condit ions orig ina ting from th e ph ysica l source s use d to de ve lop th eda ta b a s e m a y b e re fle cte d in th e da ta supplie d. Th e re que stor m ust b e a wa reof da ta conditions a nd ultim a te ly b e a r re spon sib ility for th e a p propria te use

of th e inform a tion with re spe ct to possib le e rrors, orig in a l m a p sca le , colle ction m e th odolog y, curre n cy of da ta , a nd oth e r spe cific conditions t o ce rta in da ta .Th is inform a tion doe s not de p ict a ll p ossib le re source s. Fie ld ve rifica tion of a ll da ta is re quire d for site -spe cific proje cts. Th is inform a tion is de e m e d

re lia b le , b ut not g ua ra nte e d.

FIGURE 5

1 inch = 300 feet

0 110 220 330 440Fe e t

0 60 120 180 240Ya rds

1:3,605Scale

IGI&S MCAS BeaufortBLD 616 Rm 125Rand Th acker843.228.6702

CO NTACT INFO RMATIO N

O ur Mission is to Prov ide precise and reliable geospatial in fo rm ation and m anaged IT/GIS serv ices to enable v isualization and use by

MCIEAST and Installations, and oth ercom m ands as appro v ed by CG MCIEAST–CAMLEJ, to m eet th e installation m anagem en

t m issio n and th e broader needs of th e Marine Corps.

µ

LegendB Ne w P ole / Ne w Lig h t

R Ne w P ole / Ne w Lig h t

Le ve l 2 Fe nce To Be Re pla ce dExisiting Fe nceStructure Are aBuildingSite