96
1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE PROGRAM

1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

Embed Size (px)

Citation preview

Page 1: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

WEATHERIZATION TECH 101

NASCSP 2011

WEATHERIZATION ASSISTANCE PROGRAM

Page 2: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

2 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Basic Audit Tools

AUDITOR’S TOOLBOX

Photos courtesy of The US Department of Energy

Page 3: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

3 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Tool Case

AUDITOR’S TOOLBOX

Photos courtesy of The US Department of Energy

Page 4: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

4 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Vision Enhancers

Sony digital cameraSony digital camera BoroscopeBoroscope

Flir InfraredFlir Infrared

Testo Video ProTesto Video Pro

AUDITOR’S TOOLBOX

Photos courtesy of The US Department of Energy

Page 5: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

5 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Combustion Appliance Testing

Above (left to right):• Thermometer.

• Draft Gauge.

• Inspection mirror.

• Gas leak detection bubbles.

• Smoke pump and smoke test filter paper.

• Combustion analyzer.

Above counter-clockwise from lower left:• Pipe wrenches.

• Long lighter.

• Gas leak detector.

• Inspection mirror.

AUDITOR’S TOOLBOX

Photos courtesy of The US Department of Energy

Page 6: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

6 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Smoke

Wizard Stick

AUDITOR’S TOOLBOX

Photos courtesy of The US Department of Energy

Page 7: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

7 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Manometers & Gauges

Magnahelicgauges

DG-700(Energy Conservatory)

DM-2(Retrotec)

AUDITOR’S TOOLBOX

Page 8: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

8 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Blower Door with Infrared

Without Blower Door With Blower Door Running

AUDITOR’S TOOLBOX

Page 9: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

9 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Pressure Pan

AUDITOR’S TOOLBOX

Photo courtesy of The US Department of Energy

Page 10: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

10 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Diagnosing Ducts

Common mobile home duct pattern

Bedroom 0.8 PaBedroom 1.2 PaBath 2.4 PaFurnace Closet (living rm) 2.6 PaLiving Room 2.0 PaKitchen 1.2 PaKitchen 0.5 Pa

Total: 10.7 Pa = seal ducts

2.4 Pa at bath register & 2.6 Pa at living room register indicate a large leak between them, most probably at the furnace plenum.

AUDITOR’S TOOLBOX

Photo Source: US Department of Energy

Page 11: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

11 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Duct Blaster

AUDITOR’S TOOLBOX

Photo courtesy of The US Department of Energy

Page 12: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

12 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Measuring Exhaust Fan Flow

Energy Conservatory Exhaust Fan Flow Meter with DG-700 Pressure & Flow Gauge

AUDITOR’S TOOLBOX

Photos courtesy of The US Department of Energy

Page 13: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

13 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Moisture Assessment

Sling psychrometer.

“Pin” or “Non contact” moisture meters

Indoor/outdoor reads RH.

AUDITOR’S TOOLBOX

Page 14: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

14 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Circuit Testing & Tracing

Tells auditor percent overload on circuit, among other outputs.Tells auditor percent overload

on circuit, among other outputs.

Circuit tracer determines which fuse/breaker controls

which circuit.

Circuit tracer determines which fuse/breaker controls

which circuit.

Live wire tester, especially useful for determining if knob

& tube wiring is still live.

Live wire tester, especially useful for determining if knob

& tube wiring is still live.

AUDITOR’S TOOLBOX

Page 15: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

15 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Base Load Analysis

Watt meter.Watt meter.

Newer model watt meter -

BrultechKit60 with 1220B.

Newer model watt meter -

BrultechKit60 with 1220B.

Indoor/outdoor thermometer, useful in measuring refrigerator/freezer

compartment temperatures.

Indoor/outdoor thermometer, useful in measuring refrigerator/freezer

compartment temperatures.

AUDITOR’S TOOLBOX

Page 16: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

16 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Typical Weatherization Measures

In no particular order

Page 17: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

17 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Air Sealing and Attic PrepWEATHERIZATION INSTALLER/TECHNICIAN INTERMEDIATE

WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010

Page 18: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

18 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Air flow is measured in cubic feet per minute.

• Also written as ft3/min, or CFM.

• 1 CFM OUT = 1 CFM IN.

• Air flow takes the path of least resistance.

• Air moves from high-to low-pressure areas.

• Air moves from high-to low-temperature areas.

Air Leakage Review

AIR SEALING & ATTIC PREP

Page 19: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

19 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Primary Air Infiltration Sites

Data courtesy of the California Energy Commission

5% Fans & Vents

12% Windows

13% Doors

15% Plumbing PenetrationsFireplace 16%

Electric Outlets 2%

Floors, walls, and Ceilings 36%

AIR SEALING & ATTIC PREP

Page 20: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

20 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

1212

1111

101099

88

7766

5544

33

1. Urethane foam (spray foam)

2. Foam board

3. Sheet metal/foil

4. Mastic and gloves

5. High-temperature caulk

6. Utility flags

7. Insulation rulers

8. Tin snips and zip ties

9. Stapler

10. Weatherstripping

11. Zip tie tightening tool

12. Utility knife

Common Tools for Attic Prep

2211

AIR SEALING & ATTIC PREP

Page 21: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

21 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Check typical hot-spots:

• Flues and plumbing vents.

• Wire pathways.

• Recessed fixtures (lights and fans).

• Chimney penetrations.

Signals:

• Blower door, smoke.

• Dirty or discolored Insulation.

Finding Air Leaks

AIR SEALING & ATTIC PREP

Photos courtesy of the US Department of Energy

Page 22: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

22 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

GAPS ≤ 1/4”Caulk

General Guidelines

Energy Blast ServicesThe Daily Green

GAPS 1/4” – 3”

Spray foam

OTHERFoam board, fiberglass in plastic bags,

etc.

AIR SEALING & ATTIC PREP

Page 23: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

23 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Sometimes sealing air leaks requires repairing damaged drywall.

Drywall Repair

AIR SEALING & ATTIC PREP

Photos courtesy of the US Department of Energy

Page 24: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

24 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Recessed Light Fixtures

High Temperature Issues

Flues

Maintain appropriate clearancesMaintain appropriate clearances

High-temp caulkHigh-temp caulk

IC Rated Fixture

Non-IC Rated Fixture

AIR SEALING & ATTIC PREP

Photos courtesy of the US Department of Energy

Page 25: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

25 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• No insulation over knob & tube wiring.

• All home electrical systems should be properly grounded.

• Wiring splices enclosed in junction boxes and marked with a flag visible above attic insulation.

Wiring

Knob and tube wiring is common in old homes.Knob and tube wiring is common in old homes.

AIR SEALING & ATTIC PREP

Photo courtesy of the US Department of Energy

Page 26: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

26 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Attic InsulationWEATHERIZATION INSTALLER/TECHNICIAN INTERMEDIATE

WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010

Page 27: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

27 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Cost-Effective Insulation Levels

ATTIC INSULATION

Page 28: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

28 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Not Enough Insulation

ATTIC INSULATION

Page 29: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

29 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Too Much Insulation

ATTIC INSULATION

Page 30: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

30 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Measuring Blown-In Insulation

How much is in that back corner?

Staple rulers every 15 feet

for even coverage.

ATTIC INSULATION

Photo courtesy of the US Department of Energy

Page 31: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

31 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Properly Insulated Attic

Dam maintains clearance around flue

Dam maintains clearance around flue

Flags indicate juncture boxes, recessed lightsFlags indicate juncture boxes, recessed lights

Even layer of appropriate depth

Even layer of appropriate depth

ATTIC INSULATION

Photo courtesy of the US Department of Energy

Page 32: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

32 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Dense-Pack Sidewall InsulationWEATHERIZATION INSTALLER/TECHNICIAN INTERMEDIATE

WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010

Page 33: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

33 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

It Works

“It is not unusual to reduce overall house

leakage by 30% to 50% by dense-packing walls and other closed-in cavities.”

- Home Energy Magazine, Nov/Dec 1995

DENSE-PACK SIDEWALL INSULATION

Page 34: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

34 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

1. Siding remover

2. Eye protection and dust mask

3. Hose cut at 45 degree angle

4. Drill bit

5. Plugs

6. Mister (for LSW)

7. Corded, 1/2” drill

8. Cellulose

Typical Tools Used

33

11

22

77

6644

88

55

DENSE-PACK SIDEWALL INSULATION

Page 35: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

35 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Maintain equipment.

• Inspect walls.

• Determine fill strategy.(attic or wall, interior or exterior)

• Remove siding (if exterior).

• Drill.

• Fill.

• Replace/repair.

Order of Operations

DENSE-PACK SIDEWALL INSULATION

Page 36: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

36 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Blow in from attic if you can.

• Interior.

• Exterior.

• Drill at top, bottom, middle?

Determine Fill Strategy

DENSE-PACK SIDEWALL INSULATION

Page 37: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

37 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Remove Siding

Aluminum Vinyl

Wood Asbestos

If it can be avoided, remove asbestos siding! Interior blow

DENSE-PACK SIDEWALL INSULATION

Photo courtesy of the US Department of Energy

Page 38: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

38 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Aluminum Siding

Pry and slide / May need metal cutter.

DENSE-PACK SIDEWALL INSULATION

Photo courtesy of the US Department of Energy

Page 39: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

39 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Vinyl Siding

Easier to work with than metal.

DENSE-PACK SIDEWALL INSULATION

Photo courtesy of the US Department of Energy

Page 40: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

40 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Wood Siding

Remove clapboards and pressed board.

Remove enough shingles to re-cover holes.

DENSE-PACK SIDEWALL INSULATION

Photo courtesy of the US Department of Energy

Page 41: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

41 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Properly size bit to accept fill tube and movement.

• Drill at angle fill-tube will enter.

• Address large cavities first to get blower busy before tackling details.

• Probe around hole.

Drill

DENSE-PACK SIDEWALL INSULATION

Photos courtesy of the US Department of Energy

Page 42: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

42 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Probe cavities for blocks - request holes where needed.

• If holes are drilled in the middle of the wall, fill top then bottom.

• Feed hose to farthest point from hole, then pull back 12”.

• Cellulose-only blower: pull hose out 1’ at a time (Faster blower: pull out 2’).

• Adjust air gate: 8’ Cavity should fill in 2 - 4 minutes.

Fill

DENSE-PACK SIDEWALL INSULATION

Page 43: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

43 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Check fill holes: Shouldn’t be able to stick your finger in.

• Check material-to-Volume ratio: One 30 lb. bag should almost fill 3 8’ cavities with 2x4 16” O.C. framing.

Proper Density

DENSE-PACK SIDEWALL INSULATION

Photo courtesy of the US Department of Energy

Page 44: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

44 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

If you’ve blown for overfour minutes without reaching proper density, find out where cellulose is going!

Trouble-Shooting or Shooting Trouble?DENSE-PACK SIDEWALL INSULATION

Photo courtesy of the US Department of Energy

Page 45: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

45 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Replace and Repair

The job isn’t done until the house is put back together.

The job isn’t done until the house is put back together.

DENSE-PACK SIDEWALL INSULATION

Photo courtesy of the US Department of Energy

Page 46: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

46 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MOBILE HOME TRAINING

Duct Diagnostics and Repair

WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010

Page 47: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

47 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

A typical mobile home downflow distribution system

Forced Air System Operation #1

DUCT DIAGNOSTICS AND REPAIR

Page 48: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

48 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Forced Air System Operation #2

Furnace Duct

Vents

Return Air

DUCT DIAGNOSTICS AND REPAIR

Page 49: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

49 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Problems and Opportunities

Photos courtesy of PA WTC

New factory installation includes

duct tape

New factory installation includes

duct tape

Failed duct tape

Failed duct tape

DUCT DIAGNOSTICS AND REPAIR

Page 50: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

50 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Visual Checks #1

Photos courtesy of PA WTC

Duct registers are common leakage sites

DUCT DIAGNOSTICS AND REPAIR

Page 51: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

51 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Desperate times call for desperate measures…

…when the crawl space is the warmest room of

the house!

Photos courtesy of PA WTC

Visual Checks #2DUCT DIAGNOSTICS AND REPAIR

Page 52: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

52 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Visual Checks #3

Photos courtesy of PA WTC

Large holesLarge holes

Branch duct leakageBranch duct leakage

DUCT DIAGNOSTICS AND REPAIR

Page 53: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

53 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

The old flashlight and mirror trick

Visual Checks #5

Is that a squeegee down there?!

Photos courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 54: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

54 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Furnace Connection

DuctTermination

Crossover Duct

Branch Duct

Register Boot

TRUNK DUCT

Visual Checks #6

Typical Air Leakage Locations

DUCT DIAGNOSTICS AND REPAIR

Page 55: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

55 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Depressurize the home to 50 pascals

• Pressure pan each register location

• Record pressure differences

• Repair ducts and retest

Pressure Pan Testing

The goal is to reduce pressure pan readings at each register location to less than 1 pascal.

Remember this number!

Photo Source: US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 56: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

56 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Duct repair and sealing techniques

• Inspect ducts and boots

• Repair or replace ducts and boots

• Clean ducts

• Seal with mastic and fiberglass mesh tape

• Seal ends of trunk line

• Repair and seal furnace base DUCT INSPECTION AND MODIFICATION TOOLS

Repairing & Sealing Ducts #1

Photo courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 57: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

57 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Inspect for blockage and

loose seams

Check the flanges and inspect for

damage

Repairing & Sealing Ducts #2

Photos courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 58: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

58 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Make sure to clean ducts before sealing

Repairing & Sealing Ducts #3

Photo courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 59: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

59 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Repairing & Sealing Ducts #4

Repair or replace the boot

Repair or replace the boot

Photo courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 60: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

60 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Aluminum coil stock and boot fabrication

Photo courtesy of PA WTC

Repairing & Sealing Ducts – Materials #1

Photo courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 61: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

61 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Butyl-backed tape

Repairing & Sealing Ducts – Materials #2

Photo courtesy of PA WTC

DUCT DIAGNOSTICS AND REPAIR

Image Source: http://www.hardcast.com/PRODUCTS/pr_detail.asp?pid=3

Page 62: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

62 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Repairing & Sealing Ducts – Materials #3

Mastic sealant

Photo courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Image Source: http://www.rcdmastics.com/pd6.asp

Page 63: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

63 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Use fiberglass mesh tape to span gaps larger than

¼ inch

Latex gloves are often your mastic

brush

Sealing with Mastic #1

Photos courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 64: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

64 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Seal the duct,then patch the belly

board

Mechanically fasten and seal with butyl-backed

aluminum tape or mastic

Repairing and Sealing Ducts #1

Photo courtesy of PA WTCPhoto courtesy of WV GOEO

DUCT DIAGNOSTICS AND REPAIR

Page 65: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

65 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Repairing and Sealing Ducts #2

Re-attach disconnected ductwork

Photo courtesy of PA WTC

DUCT DIAGNOSTICS AND REPAIR

Page 66: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

66 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Results!

Post Pressure Pan Testing

Photos courtesy of the US Department of Energy

DUCT DIAGNOSTICS AND REPAIR

Page 67: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

67 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Basements and Crawl Spaces

WEATHERIZATION INSTALLER/TECHNICIAN INTERMEDIATE

WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010

Page 68: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

68 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Basements

– Intentionally or unintentionally conditioned

– Unconditioned

• Crawl Spaces

– Vented

– Unvented

– Conditioned

Foundation Types

• Pier and beam (exposed floor)

• Concrete Slabs

− Insulated

− Uninsulated

BASEMENTS & CRAWL SPACES

Page 69: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

69 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Slab on Grade Foundation

Basement or Crawl Space Foundation

Photo courtesy of PA WTCPhoto courtesy of Wikipedia

Pier and Beam Foundation

BASEMENTS & CRAWL SPACES

Foundation Types

Photo courtesy of PA WTC

Page 70: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

70 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

ConditionedBasement

UnconditionedBasement

ConditionedMain Level

ConditionedBasement BELOW

GRADE

ConditionedMain Level

UnconditionedBasement

Conditioned or Unconditioned?

ABOVEGRADE

Thermal BarrierAir Barrier

BASEMENTS & CRAWL SPACES

Page 71: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

71 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Conditioned

• More than 50% below grade.

• Relatively tight or unvented foundation.

• A living space.

• Intentional or unintentional space conditioning.

Unconditioned

• Less than 50% below grade.

• Leaky, vented, or severely degraded foundation.

• Not a living space.

• No intentional or unintentional space conditioning.

Conditioned or Unconditioned?

Guidelines

BASEMENTS & CRAWL SPACES

Page 72: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

72 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Basement Diagnostics

Zonal Pressure Diagnostics (ZPD)

• Determine interconnectivity of basement or crawlspace WRT house.

Pressure Pan Testing

• Determine relative leakiness of ducts to outside.

CAZ Testing

• Diagnose problems caused by negative pressures.

BASEMENTS & CRAWL SPACES

Photo courtesy of PA WTC

Page 73: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

73 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Unconditioned Basements

· Air seal all air pathways between the basement and house.

· Seal all return and supply ducts.

· Insulate all duct work to the recommended R-value.

· Insulate open floor joists to the recommended R-value with fiberglass batt insulation. Be sure to fit insulation batts tightly to the bottom of the sub-floor and attach them with wire supports.

· Insulate enclosed floor cavities with dense-pack insulation.

· Pressure pan measurements on duct registers should read close to 0 Pa.

Basement Retrofit Options

BASEMENTS & CRAWL SPACES

Page 74: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

74 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Photo courtesy of the US Department of Energy

Page 75: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

75 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Photo courtesy of the US Department of Energy

Page 76: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

76 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Conditioned Basements

• Air seal perimeter mud sill, band joist and all air pathways between the basement and the house.

• Seal return plenum and all return ducts for safety.

• Seal major leaks in supply ducts by mechanically reconnecting boots to register transitions.

• Insulate band joist area to recommended R-Value.

• Consider insulating basement walls.

• Use ZPD to verify that the conditioned crawl space with reference to the house is close to 0 Pa.

Basement Retrofit Options

BASEMENTS & CRAWL SPACES

Page 77: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

77 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

2 ft

5 ft

Manual J HTM (Btu/hr/sq ft)

43.5

10.6

7.4

Butte,Montana

35.7

8.7

6.1

15.3

3.7

2.6

BASEMENTS & CRAWL SPACES

Heat Loss by Soil Depth

Kokoma, Indiana

Tampa,Florida

>6 ft

Page 78: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

78 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

• Basements and Crawlspaces

Photo courtesy of INCAP

Page 79: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

79 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Photo courtesy of INCAP

Page 80: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

80 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Photo courtesy of INCAP

Page 81: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

81 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Basements and Crawlspaces

Photo courtesy of INCAP

Page 82: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

82 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Foaming the Band Joist

BASEMENTS & CRAWL SPACES

Photo courtesy of the US Department of Energy

Page 83: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

83 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Materials, Tools & EquipmentWEATHERIZATION INSTALLER/TECHNICAN FUNDAMENTALS

WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010

Page 84: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

84 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Photo courtesy of NRCERT

Page 85: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

85 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Hoses

Insulation Hoses & Hose Reel

3” Hose Wall Tube Hose Reel

Page 86: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

86 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Sidewall Drills & Bits

Page 87: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

87 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Drill Shroud

Photos courtesy of the US Department of Energy

Page 88: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

88 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Air Respirator

Positive Pressure Supplied-Air Respirator

Photos courtesy of the US Department of Energy

Page 89: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

89 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Duct Mastic

Photo courtesy of the US Department of Energy

Page 90: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

90 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Combustion Safety Equipment

Photos courtesy of the US Department of Energy

Page 91: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

91 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Vent Pipe

B-Vent L-VentSingle-WallBlack Pipe

Page 92: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

92 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Trucks & Trailers

Photos courtesy of NRCERT

Page 93: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

93 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

NRCERT Truck Side Hatch

Photo courtesy of the US Department of Energy

Page 94: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

94 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Photos courtesy of the US Department of Energy

Page 95: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

95 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

MATERIALS, TOOLS & EQUIPMENT

Photo courtesy of the US Department of Energy

Page 96: 1 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010eere.energy.gov WEATHERIZATION TECH 101 NASCSP 2011 WEATHERIZATION ASSISTANCE

96 | WEATHERIZATION ASSISTANCE PROGRAM STANDARDIZED CURRICULUM – August 2010 eere.energy.gov

Thank you!Kelly Cutchin