1 Product Line Review. 2 3 RS Series UV & UV / WBIR Alarm Relay Analog Safe Area use only Fire Sentry still sells a lot of these!

Embed Size (px)

Citation preview

1

Product Line Review

2

Product Line Review

3

RS SeriesUV & UV / WBIR

Alarm Relay

Analog

Safe Area use only

Fire Sentry still sells a lot of these!

4

UV only

RS-0010RS-0010(B)

9 volt battery12-24 VDCbuilt-in hornnon-latching relayNO or NC contacts

UV only

RS2-0010

FS2-0010(B)

12-24 VDC

latching relay

NO or NC contacts

UV/VIS/WBIR

RS2D-00098

FS2DCR-00098

12-24 VDC

latching relay

non-latching relay

form C contacts

RS Series

5

Model SS2 UV / WBIR / VIS Explosion Proof

- Indoor & Outdoor use Internal Self-Test FirePic™ Alarm & Fault Relays FireBus™ RS485 Use Unitized or with CM1-A Controller Versions for specialty applications

requiring high speed response, such as Airbag and Munitions manufacturing

6

24 VDC

(1) FAULT RELAY– NO/NC Normally Energized

(1) FIRE ALARM Relay – NO/NC Normally De-Energized

Model SS2 (Unitized Mode)

Note:Sensitivity Setting: 60 feetElectronics Self Test Only

RS-485 FireBus™ Protocol to PC

7

Model SS3 Safe Area use

UV & UV / WBIR / VIS

FirePic™

Alarm Relay

FireBus™ RS485

Use Unitized or with CM1-A Controller

8

Silane Gas Cabinets Clean Rooms Warehouses Computer Rooms

Model SS3PRODUCT APPLICATIONS

Note:NEMA 1 Enclosure (Use only in Non-Hazardous Areas)

9

Model SS4UV & UV / WBIR / VISExplosion Proof

- Indoor & Outdoor useOptical and Internal Self-TestFirePic™Alarm, Verified Fire & Fault RelaysFireBus RS485Use Unitized or with CM1-A ControllerOptimized version for Hydrogen,

Natural Gas, Methanol & Ethanol Fires

10

Petrochemical Plants

Refineries Petroleum Product

Pipelines Gas Processing

Plants Offshore Drilling and

Production Platforms Gas Compressor

Buildings Petroleum Prod.

Pumping Stations Product Storage

Terminals

Crude & Product Tank Farms

Gas Turbine Enclosures

Gas Collection Facilities

Marine Terminals Rail Loading &

Unloading Terminals Gasoline Loading

Terminals LNG & LPG Storage

and Distribution Silane Gas Cabinets Silane Gas Storage

Aircraft Hangars, Commercial and Military

Power Plants Paints & Solvents

Storage Aerosol Filling

Facilities Cogeneration Plants Warehouses Engine Test Cells Marine Engine

Rooms

Model SS2 & SS4PRODUCT APPLICATIONS

11

24 VDC

(1) FAULT RELAY– NO/NC Normally Energized

(1) FIRE ALARM Relay – NO/NC Normally De-Energized

(1) FIRE VERIFY RELAY – NO/NC Normally De-Energized

RS-485 FireBus™ Protocol to PC

Model SS4 (Unitized Mode)

Note:Factory Sensitivity Setting: 45 feet, (selectable 60, 30 and 15 feet)Through the Lens & Electronics Self Test

12

Up to 30 Devices in the Loop (4) PROGRAMMABLE ZONE

ALARM RELAYS- NO/NC Normally De-Energized

(1) MASTER ALARM RELAY - NO/NC

Normally De-Energized

(1) FAULT RELAY - NO/NC Normally Energized

FS2000 SYSTEM

SS2-A

SS4-A

SS4-A

SS2-A

SS3-A

FireBus™ ProtocolRS-485 4 Wire Loop

CM1-A Controller

120 VAC

RS-232 PC Communication

13

Model FS7 The World’s largest

selling Fire Detector for Semiconductor Wet Benches!

NIR / WBIR / VIS Two Stage Alarm FM Approved Leak-proof, Polypropylene Housing Unitized or Controller based versions Six FirePics™ FireBusII™ RS485

14

Clean Rooms Wet Bench Working Surfaces Clean Room Pump & Equipment Area Wet Bench Plenum Area IPA & Chemical Stations

Model FS7 SystemPRODUCT APPLICATIONS

15

Equipment Area behind Wet Bench

Robot Wafer Load and Unload Area

Plenum Area under Process Tanks

Surface Area detection, includingrobot deck area acrossProcess Tanks

Head Case

Typical Location of Detectors

16

24 VDC

To Next Junction Box

Junction Box

(1) FAULT Relay – NC Normally Energized

(4) Programmable Zone Alarms NC – Normally De-Energized

Zone 1 - ALARM or ALERTZone 2 - ALARM or ALERTZone 3 - ALARM or ALERTZone 3 - ALARM or ALERT

1 to 12 Detectors can be connected to the controller

FS7-130-SX

FS7-2173

RS-232 PC Communication

Model FS7 with FS7-130-SX Controller

17

(1) ALERT Relay – NO

(1) FIRE ALARM Relay – NO

(1) FAULT Relay – NC

(1) 24 VDC Releasing Circuit

(1) 24 VDC Annunciator (0.15A)

(1) 24 VDC Output (0.1 A)

120 VAC

Manual Call Station

Contact Device

FSWB-1

Junction Box

FS7-2173

RS-232 PC Communication

Model FS7 Detector with FSWB Controller

To Next Junction Box

1 to 9 Detectors can be connected to the controller

18

(1) FAULT Relay – NC Normally Energized

(1) ALERT Relay – NO Normally De-Energized

(1) FIRE ALARM Relay – NO Normally De-Energized

24 VDC

Model FS7-2173-2RP Unitized Fire Detector

RS-485 FireBus II™ Protocol to PC

19

Model FS10 For use with Electrostatic

Liquid and Powder PaintApplications

NIR / WBIR / VIS Complies with NFPA 33 Explosion Proof - Indoor use Unitized, Card Controller or

Wallmount Control Panel Systems FirePic™ with FireBusII RS-485

20

Electrostatic Liquid Paint Spray Line Electrostatic Powder Coating Booths Paint Drum Storage & Paint Mix Rooms Aerosol Filling Automotive Engine Testing Infrared Curing Ovens Diesel Generators (Indoors) Gas Compressor Stations (Indoors)

Model FS10PRODUCT APPLICATIONS

21

(1) ALERT Relay – NO/NC Normally De-Energized(0.5 sec Response)

(1) FIRE ALARM Relay – NO/NC Normally De-Energized(4 sec Response)

(1) FAULT Relay – NO/NC Normally Energized

(3) PROCESS SHUTDOWN Relays – NO/NCNormally Energized

Primary Application:Paint Booths

120 VAC

Note:Detector Sensitivity is 15 or 30 Feet

RS-232 PC Communication

Model FS10 Wallmount Controller

22

(1) MAJOR FAULT – NO/NC Normally Energized

(1) FIRE ALARM Relay – NO Normally De-Energized(4 sec Response)

(1) MINOR FAULT – NO Normally De-Energized

(1) ALERT / FEW Relay NC Normally Energized(0.5 sec Response)

Note:Detector Sensitivity: 15 or 30 Feet

General Finishing:

Liquid & Powder Coating

Model 2GF

RS-232 PC Communication

120 VAC

Model FS10 Card Controller

23

General Finishing:

Liquid & Powder Coating

(1) FAULT Relay – NC Normally Energized

Note:Detector Sensitivity: 15, 30, or 45 Feet, (no ALERT relay with 45 ft. sensitivity)

RS-485 FireBus II™ Protocol to PC

(1) ALERT Relay – NO Normally De-Energized(0.5 sec Response)

(1) FIRE ALARM Relay – NO Normally De-Energized(4 sec Response)

24 VDC

Model FS10-R Unitized Detector

(Relay Output Version)

24

General Finishing:

Liquid & Powder CoatingALARM: 20 Ma(4 sec Response)

ALERT: 12 mA(0.3 sec Response)

FAULT: 0 mA

NORMAL: 4 mA

Model FS10-A Unitized Detector

(Analog Output Version)

Note:Detector Sensitivity: 15, 30, or 45 Feet, (no ALERT relay with 45 ft. sensitivity)

24 VDC RS-485 FireBus II™ Protocol to PC