Product Overview
The SY2100/APP-100 Single Phase Portable Energy Meter Test Equipment designed from new digital wave compound and MCU based technology which satisfies to International Standard IEC60736 and Indian Standard IS12346.
The equipment includes voltage/current source & standard meter, operates easily through front panel Keypad/PC software to perform the entire test. The Equipment is suitable for onsite field testing of Energy Meters.
Application Key Features
Testing of Single Phase Electronic/Electromechanical Energy Meters Meter Manufacturing Industries Calibration Laboratories State Electricity Boards Research Institutes
Components
Digital Power Source 1. Signal Generator
1.1. Keyboard 2. Reference Standard Meter
2.1. With built in RSM 3. Amplifiers (Voltage & Current)
Meter Mounting Rack System 1. Scanning Head 2. Quick Connector 3. RS232/RS485 Communication Port
EMTCS (Electricity Meter Test & Calibration Software)
Customized, rugged and user friendly Portable Source. Material used is anodized aluminium alloy which is light, strong and non-
corrosive. User friendly, large color 5.7 inches LCD display, fine clearance, high
resolutions, abundant information and all relevant data measured will be displayed at a glance.
Testing of Meters in automatic/manual mode. Testing of Energy Meters of different constant simultaneously. Energy Meter connection is very quick and effective by the use of quick
connector. RS232/RS485 communication port for the automatic calibration of
electronic meter. Protection against overload, voltage short circuit & current open circuit
and alarm indication on LCD display. User Friendly software for test function, data storage, report generation,
vector display, query, save and print facility. Barcode Scanner used to enter the data of meter directly. Transfer the stored testing data in multi-formats. Suitable for testing meters as per IS:13779, IS:14697, IEC62052-11,
IEC62053-21, 22 & CBIP:88.
SY2100/APP-100 is suitable to perform all accuracy related test confirming to IS: 13779, IS: 14697, IEC: 62052, IEC: 62053, IS: 16444 Warm Up Basic Error Test Repeatability Error Test Latent Test (No Load Test)/Automatic/Manual Operation with seek mark
automatically Initial Test (Starting Test)/Automatic/Manual Operation with seek mark
automatically Dial Test/ Dosage Test Deviation Test for 24 hours Voltage Influence Test Frequency Influence Test Harmonic Test Phase circuit testing with close link Neutral circuit testing with close link Current reversal in phase/neutral circuit Neutral (Cut) missing testing
Test Features
Meter Mounting Rack
SY2100/APP-100 System Accuracy Class Class 0.1 Test Mode 1P2W Watt, 1P2W VAR Main Supply Voltage AC 230V ± 15%, 50/60 Hz ± 5% Max Input Power Consumption 600VA Communication Port RS232/RS485 Port, BNC for Pulse Output Output Voltage Voltage Range 30 V- 300 V Internal Range 60V, 240V (120V, 480V is optional) Regulative Range 0 to 125% adjustable Adjustable Step 10%, 1%, 0.1%, 0.01% Setting Accuracy of Amplitude 0.05% RG Voltage VA 50 VA Output Current Current Range 1mA – 100A Internal Range 0.1A, 1A, 5A, 20A, 100A Regulative Range 0 to 120% adjustable Adjustable Step 10%, 1%, 0.1%, 0.01% Setting Accuracy of Amplitude 0.05% RG (100mA-100A) Current Load Point (Key) 1%, 2%, 5%, 10%, 20%, 50%, 100%, 200%, 400%,
0.5Imax & Imax Current VA 100 VA Output Frequency 45~65Hz in step of 0.01Hz adjustable Output Phase Angle 0-359.99: (10:, 1:, 0.1:, 0.01: adjustable step) Test Point by key 0.5 (c), 0.8 (c), 1.0, 0.8 (L), 0.5 (L) Output Power Stability < 0.05% (3 minutes) pf=1 Output Wave Distortion <0.5 % linear load Harmonic Wave Output Harmonic Wave Output Over the range 2nd to 21st harmonic to the test
voltage and test current, fundamental frequency range: 2nd to 6th harmonic amplitude ≤ 40% 7th to 21st harmonic amplitude ≤ 10% Sum of 2nd to 21st harmonic amplitude ≤ 40%
Environmental Condition Ambient Temperature
Specified Range 5:C ~ 45:C Operating Range -10:C ~ 50:C Storage Range -20:C ~ 60:C Relative Humidity ≤ 85% Ta= 23:C Others Keyboard Control LCD menu, manual control PC Control Under Windows 98/2000/XP system, fully
automatic Power Source Dimension 500x485x200mm (width x depth x height) Power Source Weight 30kg Rack Dimension 600x550x360mm (width x depth x height) Rack Weight 19kg
Technical Specification
User interface to operate the system. Supervision and control of the test procedure. Supervision and display of the test voltage, test
current, phase angle, active power, reactive power apparent power and vector.
Indication of errors of the meters to test. Password facility for each main and sub-option. Evaluation and report of the test results. Easy to transfer data to excel files/PDF files. Print out facility with desired header.
3-6 positions meter mounting rack with scanning heads, communication port and quick connector (4 pin) for easy installation of different type meters. Single channel max. current O/P 80A 3 positions double channel max. current O/P 75A 6 positions double channel max. current O/P 40A
EMTCS Software
Mounting Rack
Hangzhou Songyang Electrical & Technology Corp., Limited Building 4, 6 Xiyuan 8
th Road, Sandun Xihu
Technology And Economic Park, Hangzhou, Zhejiang,
China Tel: +86-571-85391965, 85394178, 85301329 Fax: +86-571-85301324
Worldwide: Hongkong: Hongkong Songyang Industrial Ltd. Room 1507, 15/F, Emperor Group Center, 288 Hennessy Road, Wanchai, Hongkong Tel: +852-25732686; Fax +852-25742060 Australia: 26, outlook Drive, Don caster, VIC 3108, Australia Tel: +61-3-98487385 Spain: Calle Manuel De falla 1, 46190 Riba De Turia, Valencia, Spain