0470 Head Office / 1st Factory Industrial Zone 861-10, Toegye-dong, Chuncheon-si, Gangwon-do, Korea (ZIP code 200-944) TEL: + 82. 70. 7119. 2540 FAX: + 82. 33. 264. 5999 e-mail: [email protected] www.mek-ics.com Branch Office / 2nd Factory 5th Floor, A-dong, Woolimlionsvalley 5th. #144-3,4 Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, South Korea (ZIP code 462-739) TEL: +82. 70. 7119. 2520 FAX: +82. 31. 735. 2761 e-mail: [email protected] www.mek-ics.com PneumaCare Series Features PneumaCare MODE Single Limb Single Limb * Single Limb * Ex-Valve * Single Limb * Ex-Valve PSIMV VACV PACV VSIMV Spont+ PRVC O2Stream® ACPAP+ ABIPAP+ PneumaCare02 Optional Nasal Cannula for O2Stream® Remark : * single limb * - Single limb circuit with external exhalation valve SpO2 EtCO2 Peripherals High Pressure Oxygen Mixer Exhalation Drive Line Input Low Flow Oxygen Supply Inlet Proximal Pressure Line Input Trend Trend (72hrs)

1. MTV1000 - PNEUMACARE.pdf

Embed Size (px)

Citation preview

  • 0470

    Head Office / 1st Factory

    Industrial Zone 861-10, Toegye-dong, Chuncheon-si,Gangwon-do, Korea(ZIP code 200-944)

    TEL: +82. 70. 7119. 2540 FAX: +82. 33. 264. 5999e-mail: [email protected] www.mek-ics.com

    Branch Office / 2nd Factory

    5th Floor, A-dong, Woolimlionsvalley 5th.#144-3,4 Sangdaewon-dong, Jungwon-gu, Seongnam-si,Gyeonggi-do, South Korea (ZIP code 462-739)

    TEL: +82. 70. 7119. 2520 FAX: +82. 31. 735. 2761 e-mail: [email protected] www.mek-ics.com

    PneumaCare Series FeaturesPneumaCare

    MODE

    Single Limb Single Limb*Single Limb*Ex-Valve

    *Single Limb*Ex-Valve

    PSIMVVACV

    PACV

    VSIMVSpont+

    PRVC

    O2StreamACPAP+ABIPAP+

    PneumaCare02

    OptionalNasal Cannula for O2Stream

    Remark : *single limb * - Single limb circuit with external exhalation valve

    SpO2

    EtCO2

    Peripherals

    High Pressure Oxygen Mixer

    Exhalation Drive Line InputLow Flow Oxygen Supply Inlet

    Proximal Pressure Line Input

    Trend Trend (72hrs)

    AdminText BoxSeri Pneume cung cp tin nghi tin tin

    AdminText BoxCng ngh c o vi hiu sut cao

    AdminText Box02 Stream(iu tr lu lng cao)

    AdminText BoxACPAP+

    AdminText BoxKh nng t to kh

    AdminText Box

    AdminText BoxMY TR TH XCH TAY

    AdminText BoxMY TR TH XCH TAY

  • Encorder for setting parameter

    7 Color TFT Touch Screen

    [Technology] It is decreased Inspiratory Phase Work of Breathing through Inspiratory Trigger function and Pressure Support function. It makes possible to inhalation with small effort of patient (WOB_inspiration). It is decreased Expiratory Phase Work of Breathing through Ex_Sesnse. In this time, interrupt the flow rapidly and supply brk_time (Expiration Break Time). It makes possible to exhalation with small effort of patient (WOB_expiration) and minimize of breaths with difficulty.

    * (brk_time: Expiration Break Time): Application to most convenience respiration pattern.

    Trigger

    Pressure

    Flow-Machine

    Flow-PatientEx.time

    =Easy Expiration

    PSV

    Quick Pause

    ACPAP+(Adaptive CPAP Plus Pressure Support)

    [ACPAP+ Function] It is developed with high technology which applying to the highest class ICU ventilator and applying for a patent. It is innovated reaserch object comfortable breathing in CPAP. MEKICS created unique ACPAP+ technology completed the clinical effect and comfortablebreathing simultaneous.

    [Principal] Based on the CPAP, it is contrived to minimize of breaths with difficulty in CPAP as induction of airway open, pressure support that is decreased patients effort in inspiration, and active break (rapid pressure interruption) that makes easy of expiration.

    LAN, USB RS-232 Upgrade port

    Optional : SpO2, EtCO2

    Proximal Pressure Line InputExhalation Drive Line OutletBuilt in a High Performance

    Blower System

    MTV 1000

    PACV, PSIMV, VACV, VSIMV, SPONT(SPONT+PS), PRVC, ACPAP+, ABiPAP+ Optional : SpO2, EtCO2

    PACV, PSIMV, VACV, VSIMV, SPONT(SPONT+PS), PRVC, ACPAP+, ABIPAP+, O2 Stream with high flow oxygen supply.With High Pressure Oxygen MixerOptional : SpO2, EtCO2, Nasal Cannula for O2Stream

    PneumaCare Series(Single limb circuit use)PneumaCare

    PneumaCareO2

    Transport Ventilator for Acute Care, Sub-Acute Care,

    Homecare and Transport

    Home Care.

    Transport.

    Hospital.

    AdminText Box Mn hnh mu TFT 7"

    AdminText Box Nm iu chnh thit lp thng s

    AdminText Box La chn thm: Sp02, EtC02

    AdminText Boxu vo p lc dng gnu ra thot hi th

    AdminText BoxTch hp h thng qut gi hiu sut cao

    AdminText BoxBnh Vin

    AdminText BoxChm sc gia nh

    AdminText BoxVn chuyn

    AdminText BoxH tr p lc CPAP+ thch nghi

    AdminText Box N c pht trin vi cng ngh cao, p dng cho my th khoa Hi sc tch cc bc cao nht v bnh nhn. N c i mi d n nghin cu "thoi mi khi Th " trong CPAP. MEKICS to ra cng ngh ACPAP+ duy nht hon thnh ng thi hiu qu lm sng v thoi mi trong lc th.

    AdminText BoxNng cp cng LAN, USB, RS-232

    AdminText Box Da trn CPAP, n c sng ch ti thiu hi th kh khn trong CPAP nh cm ng h ng th, h tr p lc c gim n lc ca bnh nhn, v gin on tch cc (ngt p lc nhanh) lm cho th d dng hn.

    AdminText Box N c gim th giai on ht vo thng qua chc nng kch hot(Trigger) ht vo v chc nng h tr p lc. N lm cho c th ht phi vi n lc nh ca bnh nhn (WOB_inspiration). N c gim th giai on th ra thng qua Ex_Sense( nhy th ra c th iu chnh c). Trong thi gian ny, gin on dng chy nhanh chng v cung cp brk_time (thi gian gin on th ra). N lm cho c th th ra vi n lc nh ca bnh nhn (WOB_expiration) v gim thiu hi th mt cch kh khn.