““Lightning Bolt”Lightning Bolt”Trap Multiplexor DSM ExampleTrap Multiplexor DSM Example
Revised Mar 26 2001
2
OverviewOverview Medium Sized Central plus ROC Central Facility to control ~50 sites Sites contain few to many Win95, NT, Unix
machines running mission-critical software Variable bandwidth from sites to central
facility Some sites are autonomous entities with
local management and operations. Most sites lack local intelligence
3
Typical (Small) Site ScenarioTypical (Small) Site Scenario
NT & perhaps Unix Servers, 10-50 Windows 95 client workstations
One dedicated Enterprise Management NT Hardware Monitoring Required Database monitoring on NT/Unix Servers Linked to an ROC and a central site for
operations and support
4
Small Site StructureSmall Site Structure
Site DSMpings Nodes
Site TNG box with DSM
Site TNG box with DSM
Unix Unix
USD NT USD NT F/P NT F/P NT
Win 95 Win 95
5
Large Site ScenarioLarge Site Scenario
NT & Unix Servers, 600 Windows 95 client workstations
Two USD servers Two File/Print servers Two dedicated Enterprise Management NT Hardware Monitoring Required Database monitoring on NT/Unix Servers Linked to local ROC and central site for
operations and support
6
Large Site StructureLarge Site Structure
Site DSMsping Nodes
Site TNG box with DSM
Site TNG box with DSM
Unix Unix
USD NT USD NT F/P NT F/P NT
600*Win95
600*Win95
Site TNG boxes
with DSMs
Site TNG boxes
with DSMs
USD NT USD NT F/P NT F/P NT
7
Central Site ScenarioCentral Site Scenario
NT & Unix Servers, 1500 Windows 95 client workstations
Five USD servers Five File/Print servers Five dedicated Enterprise Management NT Hardware Monitoring Required Database monitoring on NT/Unix Servers Linked to local ROC and central site for
operations and support
8
Central Site StructureCentral Site Structure
Site DSMsping Nodes
Site TNG box with DSM
Site TNG box with DSM
Unix Unix
USD NT USD NT F/P NT F/P NT
600*Win95
600*Win95
Site TNG boxes
with DSMs
Site TNG boxes
with DSMs
USD NT USD NT F/P NT F/P NT
Site TNG boxes
with DSMs
Site TNG boxes
with DSMs
Site TNG boxes
with DSMs
Site TNG boxes
with DSMs
Site TNG boxes
with DSMs
Site TNG boxes
with DSMs
USD NT USD NT USD NT USD NT USD NT USD NT F/P NT F/P NT F/P NT F/P NT F/P NT F/P NT
9
Central Monitoring FacilityCentral Monitoring Facility
Customer required NetView and TNG to be able to simultaneously utilise site information.
ROC may need a subset view of local information
NetViewNetView
Unicenter TNG
Unicenter TNG
TrapMultiplexor
10
The TNG SolutionThe TNG Solution
Dedicated DSM or Domain Manager to provide Multiplexing of traps CA-Unicenter TNG WorldView and DSM act as one recipient of traps Agents and Lightweight DSM at each site issuing traps to Multiplexing DSM which feeds NetView and central TNG plus ROC TNG
Customization issues here are setting up the Multiplexing DSM & TNG DSM configuration
11
TNG Solution - At each siteTNG Solution - At each site
TNG Agents deployed on servers and some critical clients– HP-UX: Os, Log, Pro and Oracle Agents– NT & Win 95: Os Agent
One NT Server per site designated as a Site DSM
Site DSM heartbeats local nodes Nodes directly trap to Central DSM No need for site WVGateway
12
TNG Solution - At the Sites...TNG Solution - At the Sites...
Site DSMpings Nodes
Site DSMSite DSM
Unix Unix
Win NT Win NT Win NT Win NT
Win 95 Win 95
To Trap Multiplexor DSMat Center or ROC
Heart beating Problems
13
TNG Solution - Site DSMTNG Solution - Site DSM
Provides direct local heartbeating, raising traps on errors
No local WorldView Gateway needed Agents directly trap to Trap Multiplexor
DSM which uses TRAP_CONFIG TRAP FORWARD:Y to pass to TNG DSM
Only modified Ping Policy is employed at the Site DSM. No Agent Policy.
14
TNG Solution - Central FacilityTNG Solution - Central Facility
Require SNMP information from the sites not direct WorldView connection
DSM can act as a trap multiplexor For TNG WorldView traps are passed
through a modified DSM to provide WorldView class/status brokering
NetView receives traps from same trap multiplexor
15
Multiplexing Traps with UnicenterMultiplexing Traps with Unicenter
Central FacilityCentral Facility
StoreStore StoreStore StoreStore StoreStore
TrapMultiplexor
DSM
Traps sent to Multiplexor DSM
ROC DSMROC DSM
NetViewNetView CentralDSM TNG
CentralDSM TNG
16
Trap Multiplexor DSMTrap Multiplexor DSM
Utilizes Trap Forwarding capability Implemented using Policy Definitions Incoming traps can be ‘invisibly’ forwarded to
multiple destinations Only concern is LISTEN, FORWARD statements
use same syntax for mask of IP addresses
Only Policy employed is to Forward Traps. One line per destination - easy alteration.
17
Trap Multiplexor DSMTrap Multiplexor DSM# Example policy – only these lines in cnf file – no atp file allowed
# DSM-1
TRAP_CONFIG TRAP:192.2.*.*:*:*:*:* LISTEN
TRAP_CONFIG TRAP:192.2.*.*:*:*:*:* FORWARD:Y:192.2.4.6:162
# DSM-2 -
TRAP_CONFIG TRAP:192.29.*.*:*:*:*:* LISTEN
TRAP_CONFIG TRAP:192.30.*.*:*:*:*:* LISTEN
TRAP_CONFIG TRAP:192.31.*.*:*:*:*:* LISTEN
TRAP_CONFIG TRAP:192.29.*.*:*:*:*:* FORWARD:Y:192.30.145.245:162
TRAP_CONFIG TRAP:192.30.*.*:*:*:*:* FORWARD:Y:192.30.145.245:162
TRAP_CONFIG TRAP:192.31.*.*:*:*:*:* FORWARD:Y:192.30.145.245:162
18
Central TNG ConfigurationCentral TNG Configuration
Receives Multiplexed traps Trap origin is as if the trap were
sent directly from the agent node (invisible)
No direct heartbeating Generates & Maintains
Object Store Connects to Repository
Central FacilityCentral Facility
TrapMultiplexor
DSM
Unicenter TNG
Unicenter TNG
19
Central TNG ConfigurationCentral TNG Configuration
Central TNGDSM
TrapMultiplexor
DSM
TrapMultiplexor
DSM
Traps from Stores(Agent Traps & Hearbeat Failures)
• Central TNG DSM has standard Agent Management Policy• No direct heartbeating, failure indicated by site DSM traps instead
Traps forwarded toother SNMP
Managers
20
SummarySummary DSM used for Trap Forwarding to provide
site traps to several SNMP Managers Site DSMs only heartbeat local nodes and
trap Central TNG DSMs on Agents directly trap to Central TNG DSM Central TNG DSM handles forwarded Agent
traps with standard policy, modified heartbeat (ping) policy using traps from site DSMs