OPEN 1st CLOSE 1st C TIM Processor Socket AIRFLOW B 2 3 1 4 Chassis Front D E CAUTION: Do not over-tighten fasteners. Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2011, Intel Corporation. All rights reserved. Warning Read all caution and safety statements in this document before performing any of the instructions. Also see the Intel ® Server Board and Server Chassis Safety Information document at: http://www.intel.com/support/ motherboards/server/sb/cs-010770 .htm for complete safety information. Warning Installation and service of this product should only be performed by qualified service personnel to avoid risk of injury from electrical shock or energy hazard. Caution Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components. G42301-003 1 Preparing the Chassis If using a non-Intel server chassis, refer to the documentation that came with your chassis for preparatory steps. Observe normal ESD (ElectroStatic Discharge) procedures. Place your Intel ® Server Chassis and Intel ® Server Board on a flat anti-static surface to perform the following integration procedures. Always touch the chassis frame first, before reaching inside to install the server board, make server board connections or install other components. Tools Required Fastener Identification Guide Anti-static wrist strap #2 Phillips* screwdriver with minimum 7˝ length Flat-blade screwdriver Minimum Hardware Requirements To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements: Memory Type: Minimum of one 1 GB DDR3 800/1066/1333/1600 MHz ECC UDIMM/RDIMM/LRDIMM. Power: SSI EPS 5V compliant power supply, 460W minimum. Processor: Intel ® Xeon ® Processor E5-2600 series with compatible heat sink(s). Intel® Server Board S2600CO Quick Start User's Guide Thank you for buying the Intel® Server Board S2600CO. The following information will help you integrate your new server board into a server chassis. The Intel® Server Board S2600CO is designed for use with the Intel® Server Chassis P4000M series. For details on these chassis or to select a third party chassis, please visit http://www.intel.com/go/serverbuilder and http://www.intel.com/support/motherboards/server. When installing the server board into a reference chassis, refer to the reference chassis instructions. If you are not familiar with ESD (Electrostatic Discharge) procedures used during system integration, please see the Intel® Server Board S2600CO Service Guide at : http://www.intel.com/support/motherboards/server. Please boot to the Intel® Server Deployment Toolkit CD first for BIOS and firmware configuration and updates. Read all cautions and warnings first before starting your server system integration. 3 Install Server Board Bumpers Attach the Bumpers Press a bumper onto each of the five circles indicated by the solid blue arrows in the figure [ ]. B Remove the backing from each bumper. A B A CAUTION: To avoid damage to the server board, do not lay flat with the component side down. NOTE: If you are using a non-Intel server chassis, refer to the chassis documentation for bumper installation. If you are using an Intel ® Server Chassis, use the chassis bumpers that came with the chassis. 2 Installing the I/O Shield and chassis screw Stand-offs Install the I/O shield Attach the Labels to the I/O Shield (optional) IO Shield should be installed from inside of the chassis. The labels should be visible from the outside of the chassis. Insert one side edge of shield as shown. Push shield firmly into chassis opening until it clicks into place. B A Install the chassis screw stand-offs If installing the server board inside a Intel ® Server Chassis P4000M. The stand-off for the server board mounting screws come with chassis must be installed first. Following EEB standard, the server board has mounting screw holes as indicated by ... . Please install the chassis stand-offs to the accoridng chassis locations indicated by same marks. Press the labels onto the I/O shield as shown. Note: Make sure you install the labels on the correct side of the I/O shield. NIC3 NIC4 NIC1 NIC2 ID LSB Bit1 Bit2 Bit3 Bit4 Bit5 Bit6 MSB Labels on outside face of I/O shield Chassis Back Panel Opening B A A Z CPU 1 Socket CPU 2 Socket A C F G X Y H Z J Fan Kit (Only applicable for S2600COE with 150W CPU) 6 Install Heat Sink(s) Get heat sink from the shipping position. A Remove the protective film on the TIM if present. E D B C Securely re-tighten each fastener again in the same order as performed in Step E. Tighten each fastener diagonally using a #2 Phillips* screwdriver, according to the numbers shown. Align heat sink fins to the front and back of the chassis for correct airflow. Airflow goes from front-to-back of chassis. The heat sink has four captive fasteners and should be tightened using the following procedure: CAUTION: The heat sink has thermal interface material (TIM) beneath of it. Take care not to damage the thermal interface material. Use gloves to avoid injuries by sharp edges. OPEN 1st CLOSE 1st C TIM Processor Socket AIRFLOW B 2 3 1 4 Chassis Front D E CAUTION: Do not over-tighten fasteners. 5 Install the Processor(s) A. Open the Socket Lever B. Open the Load Plate A B Repeat the steps to release the lever on the other side. Push down the lever handle on the side and away from the socket to release it. A B Open the load plate all the way. Press the locking lever slightly to raise the load plate . NOTE: Release the levers in the order as shown. B 4 Install the Server Board B. Attach the Server Board A. Insert the Server Board Place the board into the chassis, making sure that back panel I/O openings and chassis standoffs align correctly. Use screws to attach the board to the chassis at the 9 locations indicated by the solid blue arrows in the figure [ ]. The directions below are for the Intel ® Server Chassis P4000M series. For a non-Intel server chassis, use the fasteners that came with your chassis. When using the Intel ® Server Chassis P4000M series, insert the front of the board first, then slide the board back so the I/O connectors fit through the I/O openings at the rear of the chassis. IMPORTANT NOTE: If you are using a non-Intel server chassis, see your chassis documentation for preparatory steps prior to server board installation. Intel ® Server Chassis P4000M Series Shown Intel ® Server Chassis P4000 Series Fastener I/O Openings Front edge of Board C. Install the Processor Take the processor out of the box and remove the protective shipping cover. CAUTION: When unpacking a processor, hold at the edges only, to avoid touching the golden contact pins. Save the protective cover. A CAUTION: The underside of the processor has components that may damage the socket pins if installed improperly. Processor must align correctly with the socket opening before installation. DO NOT DROP processor into socket! Components Note the location of the golden key at the corner of the processor. A B C Orient the processor with the socket so that the processor cutouts match the four orientation posts on the socket. B C FOXCONN LGA2011 ILM 17L61 A 1 CLOSE 1st A FOXCONN LGA2011 ILM 17L61 B 1 1 Install the Processor(s) ... continued D. Remove the Cover Press the cover to remove it. Carefully lower the load plate over the processor. E. Close the Load Plate Push down on the locking lever on the side. F. Latch the Locking Lever A B Slide the tip of the lever under the notch in the load plate. Make sure the load plate tab engages under the socket lever when fully closed. C Repeat the steps to latch the locking lever on the other side. CAUTION: Latch the locking levers in the order shown below. Save the protective cover. FOXCONN LGA2011 ILM 17L61 C FOXCONN LGA2011 ILM 17L61 B A FOXC CPU 1 Socket CPU 2 Socket

1 Intel® Server Board S2600CO Quick Start User's …...Insert one side edge of shield as shown. Push shield firmly into chassis opening until it clicks into place. B A Install the

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1 Intel® Server Board S2600CO Quick Start User's …...Insert one side edge of shield as shown. Push shield firmly into chassis opening until it clicks into place. B A Install the

OPEN 1st

CLOSE 1st

C

TIM

Processor

Socket

AIRFLOW

B

2

3

1

4

Chassis Front

D ECAUTION:Do not over-tightenfasteners.

Intel is a registered trademark of Intel Corporation or its subsidiaries in the United States and other countries. *Other names and brands may be claimed as the property of others. Copyright © 2011, Intel Corporation. All rights reserved.

Warning

Read all caution and safety statements in this document before performing any of the instructions. Also see the Intel ® Server Board and Server Chassis Safety Information document at:http://www.intel.com/support/motherboards/server/sb/cs-010770.htm for complete safety information.

Warning

Installation and service of this product should only be performed by qualified service personnel to avoid risk of injury from electrical shock or energy hazard.

Caution

Observe normal ESD [Electrostatic Discharge] procedures during system integration to avoid possible damage to server board and/or other components.

G42301-003

1 Preparing the ChassisIf using a non-Intel server chassis, refer to the documentation that came with your chassis forpreparatory steps.Observe normal ESD (ElectroStatic Discharge) procedures.Place your Intel® Server Chassis and Intel® Server Board on a flat anti-static surface to perform the following integration procedures. Always touch the chassis frame first, before reaching inside to install the server board, make server board connections or install other components.

Tools Required Fastener Identification Guide

Anti-staticwrist strap

#2 Phillips*screwdriverwith minimum7˝ length

Flat-bladescrewdriver

Minimum Hardware Requirements

To avoid integration difficulties and possible board damage, your system must meet the following minimum requirements:

• Memory Type: Minimum of one 1 GB DDR3 800/1066/1333/1600 MHz ECC UDIMM/RDIMM/LRDIMM.

• Power: SSI EPS 5V compliant power supply, 460W minimum.

• Processor: Intel® Xeon® Processor E5-2600 series with compatible heat sink(s).

Intel® Server Board S2600COQuick Start User's GuideThank you for buying the Intel® Server Board S2600CO. The following information will help you integrate your new server board into a server chassis. The Intel® Server Board S2600CO is designed for use with the Intel® Server Chassis P4000M series.

For details on these chassis or to select a third party chassis, please visit http://www.intel.com/go/serverbuilder and http://www.intel.com/support/motherboards/server.

When installing the server board into a reference chassis, refer to the reference chassis instructions.

If you are not familiar with ESD (Electrostatic Discharge) procedures used during system integration, please see the Intel® Server Board S2600CO Service Guide at : http://www.intel.com/support/motherboards/server.

Please boot to the Intel® Server Deployment Toolkit CD first for BIOS and firmware configuration and updates.

Read all cautions and warnings first before starting your server system integration.

3 Install Server Board Bumpers

Attach the Bumpers

Press a bumper onto each of the five circles indicated by thesolid blue arrows in the figure [ ].

B

Remove the backing from each bumper.

A

B

A

CAUTION: To avoid damage to the serverboard, do not lay flat with the component side down.

NOTE: If you are using a non-Intel server chassis, refer to the chassis documentation for bumper installation. If you are using an Intel® Server Chassis, use the chassis bumpers that came with the chassis.

2 Installing the I/O Shield and chassis screw Stand-offs

Install the I/O shield

Attach the Labels to the I/O Shield (optional)

IO Shield should be installedfrom inside of the chassis.The labels should be visiblefrom the outside of the chassis.

Insert one side edge of shield as shown.

Push shield firmly into chassis opening until it clicks into place.

B

A

Install the chassis screw stand-offs

If installing the server board inside a Intel® Server Chassis P4000M. The stand-off for the server boardmounting screws come with chassis must be installed first.

Following EEB standard, the server board has mounting screw holes as indicated by ... .

Please install the chassis stand-offs to the accoridng chassis locations indicated by same marks.

Press the labels onto the I/O shield as shown.

Note: Make sure you install the labels on the correct side of the I/O shield.

NIC3NIC4

NIC1 NIC2

IDLS

BB

it1

Bit

2B

it3

Bit

4B

it5

Bit

6M

SB

Labels on outsideface of I/O shield

Chassis BackPanel Opening

B

A

A Z

CPU 1 Socket

CPU 2 Socket

A C F

G

X Y

H

Z

J

Fan Kit (Only applicable forS2600COE with 150W CPU)

6 Install Heat Sink(s)

Get heat sink from the shipping position.ARemove the protective film on the TIM if present.

E

D

B

C

Securely re-tighten each fastener again in the same order as performed in Step E.

Tighten each fastener diagonally using a #2 Phillips* screwdriver, according to the numbers shown.

Align heat sink fins to the front and back of the chassis for correct airflow. Airflow goes from front-to-back of chassis.

The heat sink has four captive fasteners and should be tightened using the following procedure:

CAUTION: The heat sink has thermal interface material (TIM) beneath of it. Take care not to damage the thermal interface material. Use gloves to avoid injuries by sharp edges.

OPEN 1st

CLOSE 1st

C

TIM

Processor

Socket

AIRFLOW

B

2

3

1

4

Chassis Front

D ECAUTION:Do not over-tightenfasteners.

5 Install the Processor(s)

A. Open the Socket Lever B. Open the Load Plate

A

B Repeat the steps to release the lever on the other side.

Push down the lever handle on the side and away from the socket to release it.

A

B Open the load plate all the way.

Press the locking lever slightly to raise the load plate .

NOTE: Release the levers in the order as shown. B

4 Install the Server Board B. Attach the Server Board

A. Insert the Server BoardPlace the board into the chassis, making sure that back panel I/O openings andchassis standoffs align correctly.

Use screws to attach the board to the chassis at the 9 locations indicated by thesolid blue arrows in the figure [ ].

The directions below are for the Intel® Server Chassis P4000M series. For a non-Intel server chassis, use the fasteners that came with your chassis.

• When using the Intel® Server Chassis P4000M series, insert the front of the board first, then slide the board back so the I/O connectors fit through the I/O openings at the rear of the chassis.

IMPORTANT NOTE: If you are using a non-Intel server chassis, see your chassis documentation for preparatory steps prior to server board installation.

Intel ® Server ChassisP4000M Series Shown

Intel ® Server Chassis P4000 Series

Fastener

I/O Openings

Front edgeof Board

C. Install the Processor

Take the processor out of the box and remove the protective shipping cover.

CAUTION: When unpacking a processor, hold at the edges only, to avoid touching the golden contact pins.

Save the protective cover.

A

CAUTION: The underside of the processor has components that may damage the socket pinsif installed improperly.Processor must align correctly with the socket opening before installation. DO NOT DROP processor into socket!

Components

Note the location of the golden key at the corner of the processor.

AB

C

Orient the processor with the socket so that the processor cutouts match the four orientation posts on the socket.

B

C

FOXCONN LGA2011 ILM 17L61

A1

FOXCONN LGA2011 ILM 17L61

CLOSE 1st

A

FOXCONN LGA2011 ILM 17L61

B

1

1

Install the Processor(s) ... continuedD. Remove the Cover

Press the cover toremove it.

Carefully lower the load plate overthe processor.

E. Close the Load PlatePush down on the locking lever on the side.

F. Latch the Locking LeverA

B Slide the tip of the lever under the notch in the load plate. Make sure the load plate tab engages under the socket lever when fully closed.

C Repeat the steps to latch the locking lever on the other side.

CAUTION: Latch the locking levers in the order shown below.

Save the protective cover.

FOXCONN LGA2011 ILM 17L61CFOXCONN LGA2011 ILM 17L61

B

A

FOXCONN LGA2011 ILM 17L61

CPU 1 Socket

CPU 2 Socket