View
217
Download
3
Tags:
Embed Size (px)
Citation preview
2
ContentContent
System Integrators, Locksmiths
What is Smart Air?What is Smart Air?
General Overview
Design, functions and added values
Features and benefits
Applications
Installation scheme
What is Smart Air?What is Smart Air?
It´s autonomy access control systém which use RFID
technology 13,56 MHz integrated into the front escutcheon
Plate and battery powered. It can operate in 3 modes:
1/ Stand Alone
2/ Off line
3/ Update on Card (UoC)
Benefits : the electronic parts integrated into the front and back shield battery operation –no cables, no lead covers – easy installation ideal for use with panic function mechanical locks user friendly product available in DIN and Scandinavian range, different distances and the others
System Integrators, Locksmiths
4
ELECTRONIC LOCKELECTRONIC LOCK
This technology offers:
Bigger information capacity and data protection
Faster transmission speed Data encryption Universal applications – weding machines,
pay cards, access cards, etc. Contactless Higher realibility
As identification part can be used card, keytag, handrings, etc.
Possibility to accomodate different technologies like magstripe, etc. kontaktní čip, apod.
Very high mechanical and weather resistance.
General OverviewGeneral Overview
Supported TechnologiesSupported Technologies::
Identification Technology Mifare 13,56MHzIdentification Technology Mifare 13,56MHz
Mifare (ISO 14443A) ST Microelectronics (ISO 15693)
System Integrators, Locksmiths
5
ELECTRONIC LOCKELECTRONIC LOCK
HandleHandle Electromechanical operationElectromechanical operation
Proximity Card (MIFARE)Proximity Card (MIFARE)
Design, functions and added valuesDesign, functions and added values
Wiegand -
26bit format like an example of data storage
d1 d1 P1 8bit Facility code 16bits ID P2
Facility code FC = 0 - 255 ID = 16bitů
256 = 28 216 = 0 - 65535
System Integrators, Locksmiths
6
ELECTRONIC LOCKELECTRONIC LOCK
Design, functionsand added valuesDesign, functionsand added values
narrow design for easy installation on various types of doors (incl. profile doors)
Wide range of designs,colours and various compatible locks
All access data stored in back part –
data physically secured
Design and function Design and function
Security and ComfortSecurity and Comfort
Installation without cables and power supplies – full battery operation
All electromechanical and electronic devices are placed in back side shield, only reader head is placed from the front side – burglary resistance
Outside handle is movement free even if the Outside handle is movement free even if the lock is blocked (Scandinavian types has lock is blocked (Scandinavian types has deadbolt projection actionfeature)deadbolt projection actionfeature)
Smart Air is compatible with any cylinders – emergency opening.
System Integrators, Locksmiths
7
ELECTRONIC LOCKELECTRONIC LOCK
Design, functions and added valuesDesign, functions and added values
Available Designs:Available Designs:
Versions:
Long plate Short plate - rossete handle and cylinder cover
Covers:
Standard – for interior installation / clutch made from FerrumExtreme – for exterior installation (water resistant) / clutchmade from stainless stell with washer
Surface fininshes:
Antique BrassPVD Polish BrassPVD Satin BrassStainless Steel
System Integrators, Locksmiths
8
ELECTRONIC LOCKELECTRONIC LOCK
Design, functions and added values:Design, functions and added values:
Available Designs:Available Designs:
Long Plate withoutLong Plate withoutcylindercylinder
Long Plate withLong Plate withcylindercylinder
Short Plate with Short Plate with cylindercylinder
Long Plate with hidden Long Plate with hidden cylindercylinder
Short Plate without Short Plate without cylindercylinder
System Integrators, Locksmiths
9
ELECTRONIC LOCKELECTRONIC LOCK
Design, functions and added values:Design, functions and added values:
Handle Designs:Handle Designs:
U-shape handle for U-shape handle for emergency exits acc. to emergency exits acc. to EN179EN179
VectorVector SenaSena XaraXara ZafiraZafira PomoPomo
System Integrators, Locksmiths
10
ELECTRONIC LOCKELECTRONIC LOCK
When the lock is locked from inside, electronic privacy is active. Opening is possible only with authorization card - green and red LED is lighting together when electronic privacy is active and card present.
Features and BenefitsFeatures and Benefits
What is Electronic Privacy?What is Electronic Privacy?
FunctionFunction
Electronic privacy is optional
Electronic privacy without cylinder Electronic privacy with cylinder and thumbturn
System Integrators, Locksmiths
11
ELECTRONIC LOCKELECTRONIC LOCK
Features Features
Reading modul Reading modul
Identification technology:: 13,56MHz for read and write access of contacless cards - ISO 15693 or ISO
14443 A (more common) Reading distance: 10mm
Control unitControl unit
EEPROM memory (data protection when batteries depleted) Up to 1.500 users and up to 1.000 events (Audit trail) Reálný time clock and calendar - 14 time zones with 5 time periods each Red and green warning LED Operation modes: Passage (free way), First User, Standard, Double User
Battery module: Battery module:
Type of battery: 3 x 1,5V LR03 AAA (alkaline batteries) Estimated battery life: More than 30.000 operations (3 -4 years)
Everything under controlEverything under control
Individual locking plan for each user Limited access according time zones Cancel lost or stolen credentials Identify all and every user Get Audit trails
System Integrators, Locksmiths
12
ELECTRONIC LOCKELECTRONIC LOCK
ApplicationsApplications
TS10 TS1000 TS1000 UoC (Stand Alone) (Off Line) (Update on Card) Licence Licence Licence ID card reading – no sector Sector reading– user can choose Sector reading– user can
choose (Software + Data + Key) (Software + Data + Key) - Portable Programmer Portable Programmer - Encoder Encoder - - Updater Credentials Credentials Credentials
Same HW for all management systems.
Possibility to upgrade Stand Alone to OffLine and/or Update on Card without removing the lock from the door.
System Integrators, Locksmiths
13
ELECTRONIC LOCKELECTRONIC LOCK
Applications:Applications:
Stand Alone - TS10Stand Alone - TS10
Kit contents:
Licence Card –Programming Card- Mifare 1kLicence Card –Programming Card- Mifare 1k 25pcs of Mifare user cards25pcs of Mifare user cards Emergency battery packEmergency battery pack
Programming is provided with presenting of Programming is provided with presenting of
Licence Card and after the user cards.Licence Card and after the user cards.
System Integrators, Locksmiths
14
ELECTRONIC LOCKELECTRONIC LOCK
Applications:Applications:
Stand Alone - TS10Stand Alone - TS10
User registration:User registration:
1.1. Present the Present the programming card (red card)programming card (red card)
2.2. Present Present user´s card/cards foruser´s card/cards for for registration into lock memory for registration into lock memory
3.3. Close the programming sequency – present Close the programming sequency – present programming card again programming card again (programming (programming sequency is autamtically closed after 10s of no activity)sequency is autamtically closed after 10s of no activity)
System Integrators, Locksmiths
15
ELECTRONIC LOCKELECTRONIC LOCK
Applications:Applications:
Stand Alone - TS10Stand Alone - TS10
System Integrators, Locksmiths
User erasing:User erasing:
1.1. Present the Present the programming card (red card)programming card (red card)
2.2. Present Present user´s card/cards foruser´s card/cards for for erasing from lock memory for erasing from lock memory
3.3. Close the programming sequency – present Close the programming sequency – present programming card again programming card again (programming (programming sequency is autamtically closed after 10s of no activity)sequency is autamtically closed after 10s of no activity)
16
ELECTRONIC LOCKELECTRONIC LOCK
Applications:Applications:
Stand Alone - TS10Stand Alone - TS10
Lock Memory Delete:Lock Memory Delete:
1., 2. and 3. 1., 2. and 3. Present 3x programming card to delete the lock memory.Present 3x programming card to delete the lock memory.
System Integrators, Locksmiths
17
ELECTRONIC LOCKELECTRONIC LOCK
Applications:Applications:
Emergency opening with battery pack:Emergency opening with battery pack:
1.1. When operating batteries are depleted - LED is blinking after user card presentingWhen operating batteries are depleted - LED is blinking after user card presenting
2.2. Connect the battery pack through jack plug in into the antenna connectorConnect the battery pack through jack plug in into the antenna connector
3.3. Present user card, open the door and replace the operation batteries in the lock shieldPresent user card, open the door and replace the operation batteries in the lock shield
Stand Alone - TS10Stand Alone - TS10
System Integrators, Locksmiths
18
ELECTRONIC LOCKELECTRONIC LOCK
LicenceLicence TS 1000 Software Program and locking plan maintanance
- locking plan (DATA)- each locking plan has unique systém code
Autorization key- encrypted authorization keyw with istallation
systém code
Portable programmerPortable programmer Dowlnload and upload of data into and from the locks
Encoder:Encoder: cards, keytags, etc.
Updater (Update on Card System)Updater (Update on Card System) On line wall reader Automatic information update
- Audit trail - Modifications in Matrix
Off line / Update on Card Off line / Update on Card
Applications:Applications:
System Integrators, Locksmiths
Easy to install and easy to use Step 1 Creation of the locking plan in
the computer. Step 2 Download the information to
the Portable Programmer. Step 3 Program the locks with the
Portable Programmer. Step 4 Encode the credentials with
the Smartair encoder.
19
Off Line SystemComponents
PP
TS1000
Software
Encoder
Credentials (Mifare Classic)
Electronic Locks
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
20
Off Line System
Electronic Lock
Credential
System Code
User ID / Time Zone / Issue Date & Time
Time Zones
Holidays
DST
Clock
State Table
Required Grant Name
Audit Trail
System Code
User ID
Activation / Expiration Date & Time
Issue Date & Time
Given Grant Names
Software
System Code
Users
Doors
Time Zones
Matrix
State Tables
Grant Names
Data
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
21
Off Line System
SoftwareSystem Code
UsersUser Name
Group
Expiration and Activation Dates
DoorsDoor Name
Group
Time Zones (Optional)14 Time Zones / 5 Periods of Time
Calendar (Holidays) / DST
Special FunctionsGrant Names
State Tables
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
22
Off Line System
Software
MatrixWho – Where - When
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
23
Off Line System
Electronic Locks
TS1000
Software
Portable Programmer
Electronic Lock
Matrix
User ID1; Time Zone; Card’s Issued Date & Time
User ID2; Time Zone; Card’s Issued Date & Time
User ID3; Time Zone; Card’s Issued Date & Time
(Up to 1.500)
Time Zone 1
Time Zone 2
Time Zone 3
Time Zone 4
(Up to 14)
Holiday 1
Holiday 2
(Up to 365)
DST 1
DST 2
Clock (Date & Time)
Audit Trail (Up to 1.000 events)
System Code
Operations with the Portable Programmer
Initialise First Programming
Update Download modifications in the locking plan
Audit Trail Get the Audit Trail Stored in the lock
Open Emergency Opening
State Table Required Grant
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
24
Off Line System
Credentials
TS1000
Software
Encoder Credential (Mifare Classic)
User ID
Activation Date & Time
Expiration Date & Time
Issued Date & Time
Given Grant Names
System Code
Structure of credential•For off line application only 1 Sector is needed.
•Sector Protection through Key A & Key B.
•Multi-application : Sector selection in the TS1000 Software.
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
25
Off Line System
Architecture
Elect. Lock
Credential
System Code
User ID / TZ / Issue Date
Time Zones
Holidays
DST
Clock
State Table
Required Grant Name
Audit Trail
System Code
User ID
Act. / Exp. Date
Issue Date & Time
Given Grant Names
Software
System Code
Users
Doors
Time Zones
Matrix
State Tables
Grant Names
PP
TS1000
Software
Encoder
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
26
Update on Card
Just adding the updater...
Elect. Lock
Credential
System Code
User ID / TZ / Issue Date
Time Zones
Holidays
DST
Clock
State Table
Required Grant Name
Audit Trail
System Code
User ID
Act. / Exp. Date
Issue Date & Time
Given Grant Names
Software
System Code
Users
Doors
Time Zones
Matrix
State Tables
Grant Names
PP
TS1000
Software
Encoder
Updater
On Line
(TCP/IP)
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
27
Update on Card
Step 1
Credential
System Code
User ID
Act. / Exp. Date
Issue Date & Time
Given Grant Names
Revalidation
Software
System Code
Users
PP
TS1000
Software
Encoder
Updater
On Line
(TCP/IP) UpdaterEmbedded PC (TCP/IP Connection)
Reader
Data on CredentialActivation Date
Expiration Date
Given Grant Names
RevalidationNew feature to force the user to go to the Updater.
Optional for each user.
Revalidation Time defined for each user.
¡No need blacklist!
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
28
Update on Card
Step 2
Credential
Sector 1
System Code
User ID
Act. / Exp. Date
Issue Date & Time
Given Grant Names
Revalidation
PP
TS1000
Software
Encoder
Updater
On Line
(TCP/IP)
Audit TrailGet the User’s Audit Trail on the credential.
Capacity depends on Mifare Card.
Get the battery status on locks.
Elect. Lock
System Code
User ID / TZ / Issue Date
Time Zones
Holidays
DST
Clock
State Table
Required Grant Name
Audit Trail
Battery Status.
Sector 2
User’s Audit Trail
Battery Status
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
29
Update on CardStep 2
Credential
Sector 1
System Code
User ID
Act. / Exp. Date
Issue Date & Time
Given Grant Names
Revalidation
Memory Capacity1 Event = 8 Bytes.
Mifare 1k In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/Card) = 78 (Events/Card)
Mifare 4k In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/1k) = 78 (Events/1k)
In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/1k) = 78 (Events/1k)
In 2k 15 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 30 (Events/Sector) x 8 (Sector/2k) = 240 (Events/2k)
78 (Events/1k) + 78 (Events/1k) + 240 (Events/2k) = 396 (Events/Card)
Options in the software:Decide how many sectors are going to be used to store the User’s Audit Trail.
When the selected memory capacity is full for each user we can decide:
•The card needs revalidation (to empty the memory)
•The last event delete the first one.
Sector 2
User’s Audit Trail
Battery Status
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
30
Update on CardStep 3
Credential
Sector 1
System Code
User ID
Act. / Exp. Date
Issue Date & Time
Given Grant Names
Revalidation
Modifications in Matrix
PP
TS1000
Software
Encoder
Updater
On Line
(TCP/IP)
Update LocksUpdate the user’s locking plan (Matrix) into the locks.
Add new users.
Elect. Lock
System Code
User ID / TZ / Issue Date
Time Zones
Holidays
DST
Clock
State Table
Required Grant Name
Audit Trail
Sector 2
User’s Audit Trail
Battery Status
1 Change
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
31
Update on Card
Step 3
Credential
Sector 1
System Code
User ID
Act. / Exp. Date
Issue Date & Time
Given Grant Names
Revalidation
Modifications in Matrix
Memory Capacity1 Change requires 4 Bytes.
Mifare 1k In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/Card) =156 (Change/Card)
Mifare 4k In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/1k) = 156 (Change/1k)
In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/1k) = 156 (Change/1k)
In 2k 15 (Block/sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 60 (Change/Sector) x 8 (Sector/2k) = 480 (Change/2k)
156 (Change/1k) + 156 (Change/1k) + 480 (Change/2k) = 792 (Change/Card)
Options in the softwareDecide how many sectors are going to be used to update
the locking plan in the locks.
Sector 2
User’s Audit Trail
Battery Status
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
32
Update on Card
Step 4
Credential
Sector 1
System Code
User ID
Act. / Exp. Date
Issue Date & Time
Given Grant Names
Revalidation
Modifications in Locks
PP
TS1000
Software
Encoder
Updater
On Line
(TCP/IP)
Update Locks (On study...)Update:
Time Zones
Calendar (Holidays & DST)
State Table
Required Grant Name
Elect. Lock
System Code
User ID / TZ / Issue Date
Time Zones
Holidays
DST
Clock
State Table
Required Grant Name
Audit Trail
Sector 2
User’s Audit Trail
Battery Status
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
33
Update on Card
Updater
PP
TS1000
Software
Encoder
Updater
On Line
(TCP/IP)
Phase 1Embedded PC and reader in the same box.
Door Control in another box.
Door Control
Embedded
PC
Reader
Blocking
Device
Door
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
34
Update on Card
Updater
PP
TS1000
Software
Encoder
Updater
On Line
(TCP/IP)
Phase 2Embedded PC and door control in the same box.
Separate reader.
Reader
Embedded
PC
Door Control
Blocking
Device
Door
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
35
Update on Card
Updater
NetworkUnlimited number of Updaters
One Database Updater 1
Updater 2
Updater 3
Updater 4
Updater n
Database
Server
ETHERNET
TCP/IP
ELECTRONIC LOCKELECTRONIC LOCK
System Integrators, Locksmiths
36
ELECTRONIC LOCKELECTRONIC LOCK
Installation TemplateInstallation Template
System Integrators, Locksmiths
37
ELECTRONIC LOCKELECTRONIC LOCK
InstallationTemplateInstallationTemplate
System Integrators, Locksmiths
38
ELECTRONIC LOCKELECTRONIC LOCK
Installation TemplateInstallation Template
System Integrators, Locksmiths
39
ELECTRONIC LOCKELECTRONIC LOCK
Installation TemplateInstallation Template
SmartAir shileds SmartAir shileds
Outside shiled dimensions
40,5 x 281 x 10mm.
Inside shield dimensions
40,5 x 281 x 21mm.
Material
Stainless Steel
Lock mortise Lock mortise
Compatible with DIN and Scandinavian locksin different distancies.
Door width Door width
• From 38mm to 110mm door width. • The follower lock will have different lengths acc. to the door width. See the XLS file.• It´mandatory to provide the dimensions X and Y.
System Integrators, Locksmiths