40
1 ELECTRONIC LOCK ELECTRONIC LOCK

1 ELECTRONIC LOCK. 2 Content System Integrators, Locksmiths What is Smart Air? General Overview Design, functions and added values Features and benefits

  • View
    217

  • Download
    3

Embed Size (px)

Citation preview

1

ELECTRONIC LOCKELECTRONIC LOCK

2

ContentContent

System Integrators, Locksmiths

What is Smart Air?What is Smart Air?

General Overview

Design, functions and added values

Features and benefits

Applications

Installation scheme

What is Smart Air?What is Smart Air?

It´s autonomy access control systém which use RFID

technology 13,56 MHz integrated into the front escutcheon

Plate and battery powered. It can operate in 3 modes:

1/ Stand Alone

2/ Off line

3/ Update on Card (UoC)

Benefits : the electronic parts integrated into the front and back shield battery operation –no cables, no lead covers – easy installation ideal for use with panic function mechanical locks user friendly product available in DIN and Scandinavian range, different distances and the others

System Integrators, Locksmiths

4

ELECTRONIC LOCKELECTRONIC LOCK

This technology offers:

Bigger information capacity and data protection

Faster transmission speed Data encryption Universal applications – weding machines,

pay cards, access cards, etc. Contactless Higher realibility

As identification part can be used card, keytag, handrings, etc.

Possibility to accomodate different technologies like magstripe, etc. kontaktní čip, apod.

Very high mechanical and weather resistance.

General OverviewGeneral Overview

Supported TechnologiesSupported Technologies::

Identification Technology Mifare 13,56MHzIdentification Technology Mifare 13,56MHz

Mifare (ISO 14443A) ST Microelectronics (ISO 15693)

System Integrators, Locksmiths

5

ELECTRONIC LOCKELECTRONIC LOCK

HandleHandle Electromechanical operationElectromechanical operation

Proximity Card (MIFARE)Proximity Card (MIFARE)

Design, functions and added valuesDesign, functions and added values

Wiegand -

26bit format like an example of data storage

d1 d1                                                   P1 8bit Facility code 16bits ID P2

Facility code FC = 0 - 255 ID = 16bitů

256 = 28 216 = 0 - 65535

System Integrators, Locksmiths

6

ELECTRONIC LOCKELECTRONIC LOCK

Design, functionsand added valuesDesign, functionsand added values

narrow design for easy installation on various types of doors (incl. profile doors)

Wide range of designs,colours and various compatible locks

All access data stored in back part –

data physically secured

Design and function Design and function

Security and ComfortSecurity and Comfort

Installation without cables and power supplies – full battery operation

All electromechanical and electronic devices are placed in back side shield, only reader head is placed from the front side – burglary resistance

Outside handle is movement free even if the Outside handle is movement free even if the lock is blocked (Scandinavian types has lock is blocked (Scandinavian types has deadbolt projection actionfeature)deadbolt projection actionfeature)

Smart Air is compatible with any cylinders – emergency opening.

System Integrators, Locksmiths

7

ELECTRONIC LOCKELECTRONIC LOCK

Design, functions and added valuesDesign, functions and added values

Available Designs:Available Designs:

Versions:

Long plate Short plate - rossete handle and cylinder cover

Covers:

Standard – for interior installation / clutch made from FerrumExtreme – for exterior installation (water resistant) / clutchmade from stainless stell with washer

Surface fininshes:

Antique BrassPVD Polish BrassPVD Satin BrassStainless Steel

System Integrators, Locksmiths

8

ELECTRONIC LOCKELECTRONIC LOCK

Design, functions and added values:Design, functions and added values:

Available Designs:Available Designs:

Long Plate withoutLong Plate withoutcylindercylinder

Long Plate withLong Plate withcylindercylinder

Short Plate with Short Plate with cylindercylinder

Long Plate with hidden Long Plate with hidden cylindercylinder

Short Plate without Short Plate without cylindercylinder

System Integrators, Locksmiths

9

ELECTRONIC LOCKELECTRONIC LOCK

Design, functions and added values:Design, functions and added values:

Handle Designs:Handle Designs:

U-shape handle for U-shape handle for emergency exits acc. to emergency exits acc. to EN179EN179

VectorVector SenaSena XaraXara ZafiraZafira PomoPomo

System Integrators, Locksmiths

10

ELECTRONIC LOCKELECTRONIC LOCK

When the lock is locked from inside, electronic privacy is active. Opening is possible only with authorization card - green and red LED is lighting together when electronic privacy is active and card present.

Features and BenefitsFeatures and Benefits

What is Electronic Privacy?What is Electronic Privacy?

FunctionFunction

Electronic privacy is optional

Electronic privacy without cylinder Electronic privacy with cylinder and thumbturn

System Integrators, Locksmiths

11

ELECTRONIC LOCKELECTRONIC LOCK

Features Features

Reading modul Reading modul

Identification technology:: 13,56MHz for read and write access of contacless cards - ISO 15693 or ISO

14443 A (more common) Reading distance: 10mm

Control unitControl unit

EEPROM memory (data protection when batteries depleted) Up to 1.500 users and up to 1.000 events (Audit trail) Reálný time clock and calendar - 14 time zones with 5 time periods each Red and green warning LED Operation modes: Passage (free way), First User, Standard, Double User

Battery module: Battery module:

Type of battery: 3 x 1,5V LR03 AAA (alkaline batteries) Estimated battery life: More than 30.000 operations (3 -4 years)

Everything under controlEverything under control

Individual locking plan for each user Limited access according time zones Cancel lost or stolen credentials Identify all and every user Get Audit trails

System Integrators, Locksmiths

12

ELECTRONIC LOCKELECTRONIC LOCK

ApplicationsApplications

TS10 TS1000 TS1000 UoC (Stand Alone) (Off Line) (Update on Card) Licence Licence Licence ID card reading – no sector Sector reading– user can choose Sector reading– user can

choose (Software + Data + Key) (Software + Data + Key) - Portable Programmer Portable Programmer - Encoder Encoder - - Updater Credentials Credentials Credentials

Same HW for all management systems.

Possibility to upgrade Stand Alone to OffLine and/or Update on Card without removing the lock from the door.

System Integrators, Locksmiths

13

ELECTRONIC LOCKELECTRONIC LOCK

Applications:Applications:

Stand Alone - TS10Stand Alone - TS10

Kit contents:

Licence Card –Programming Card- Mifare 1kLicence Card –Programming Card- Mifare 1k 25pcs of Mifare user cards25pcs of Mifare user cards Emergency battery packEmergency battery pack

Programming is provided with presenting of Programming is provided with presenting of

Licence Card and after the user cards.Licence Card and after the user cards.

System Integrators, Locksmiths

14

ELECTRONIC LOCKELECTRONIC LOCK

Applications:Applications:

Stand Alone - TS10Stand Alone - TS10

User registration:User registration:

1.1. Present the Present the programming card (red card)programming card (red card)

2.2. Present Present user´s card/cards foruser´s card/cards for for registration into lock memory for registration into lock memory

3.3. Close the programming sequency – present Close the programming sequency – present programming card again programming card again (programming (programming sequency is autamtically closed after 10s of no activity)sequency is autamtically closed after 10s of no activity)

System Integrators, Locksmiths

15

ELECTRONIC LOCKELECTRONIC LOCK

Applications:Applications:

Stand Alone - TS10Stand Alone - TS10

System Integrators, Locksmiths

User erasing:User erasing:

1.1. Present the Present the programming card (red card)programming card (red card)

2.2. Present Present user´s card/cards foruser´s card/cards for for erasing from lock memory for erasing from lock memory

3.3. Close the programming sequency – present Close the programming sequency – present programming card again programming card again (programming (programming sequency is autamtically closed after 10s of no activity)sequency is autamtically closed after 10s of no activity)

16

ELECTRONIC LOCKELECTRONIC LOCK

Applications:Applications:

Stand Alone - TS10Stand Alone - TS10

Lock Memory Delete:Lock Memory Delete:

1., 2. and 3. 1., 2. and 3. Present 3x programming card to delete the lock memory.Present 3x programming card to delete the lock memory.

System Integrators, Locksmiths

17

ELECTRONIC LOCKELECTRONIC LOCK

Applications:Applications:

Emergency opening with battery pack:Emergency opening with battery pack:

1.1. When operating batteries are depleted - LED is blinking after user card presentingWhen operating batteries are depleted - LED is blinking after user card presenting

2.2. Connect the battery pack through jack plug in into the antenna connectorConnect the battery pack through jack plug in into the antenna connector

3.3. Present user card, open the door and replace the operation batteries in the lock shieldPresent user card, open the door and replace the operation batteries in the lock shield

Stand Alone - TS10Stand Alone - TS10

System Integrators, Locksmiths

18

ELECTRONIC LOCKELECTRONIC LOCK

LicenceLicence TS 1000 Software Program and locking plan maintanance

- locking plan (DATA)- each locking plan has unique systém code

Autorization key- encrypted authorization keyw with istallation

systém code

Portable programmerPortable programmer Dowlnload and upload of data into and from the locks

Encoder:Encoder: cards, keytags, etc.

Updater (Update on Card System)Updater (Update on Card System) On line wall reader Automatic information update

- Audit trail - Modifications in Matrix

Off line / Update on Card Off line / Update on Card

Applications:Applications:

System Integrators, Locksmiths

Easy to install and easy to use Step 1 Creation of the locking plan in

the computer. Step 2 Download the information to

the Portable Programmer. Step 3 Program the locks with the

Portable Programmer. Step 4 Encode the credentials with

the Smartair encoder.

19

Off Line SystemComponents

PP

TS1000

Software

Encoder

Credentials (Mifare Classic)

Electronic Locks

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

20

Off Line System

Electronic Lock

Credential

System Code

User ID / Time Zone / Issue Date & Time

Time Zones

Holidays

DST

Clock

State Table

Required Grant Name

Audit Trail

System Code

User ID

Activation / Expiration Date & Time

Issue Date & Time

Given Grant Names

Software

System Code

Users

Doors

Time Zones

Matrix

State Tables

Grant Names

Data

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

21

Off Line System

SoftwareSystem Code

UsersUser Name

Group

Expiration and Activation Dates

DoorsDoor Name

Group

Time Zones (Optional)14 Time Zones / 5 Periods of Time

Calendar (Holidays) / DST

Special FunctionsGrant Names

State Tables

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

22

Off Line System

Software

MatrixWho – Where - When

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

23

Off Line System

Electronic Locks

TS1000

Software

Portable Programmer

Electronic Lock

Matrix

User ID1; Time Zone; Card’s Issued Date & Time

User ID2; Time Zone; Card’s Issued Date & Time

User ID3; Time Zone; Card’s Issued Date & Time

(Up to 1.500)

Time Zone 1

Time Zone 2

Time Zone 3

Time Zone 4

(Up to 14)

Holiday 1

Holiday 2

(Up to 365)

DST 1

DST 2

Clock (Date & Time)

Audit Trail (Up to 1.000 events)

System Code

Operations with the Portable Programmer

Initialise First Programming

Update Download modifications in the locking plan

Audit Trail Get the Audit Trail Stored in the lock

Open Emergency Opening

State Table Required Grant

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

24

Off Line System

Credentials

TS1000

Software

Encoder Credential (Mifare Classic)

User ID

Activation Date & Time

Expiration Date & Time

Issued Date & Time

Given Grant Names

System Code

Structure of credential•For off line application only 1 Sector is needed.

•Sector Protection through Key A & Key B.

•Multi-application : Sector selection in the TS1000 Software.

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

25

Off Line System

Architecture

Elect. Lock

Credential

System Code

User ID / TZ / Issue Date

Time Zones

Holidays

DST

Clock

State Table

Required Grant Name

Audit Trail

System Code

User ID

Act. / Exp. Date

Issue Date & Time

Given Grant Names

Software

System Code

Users

Doors

Time Zones

Matrix

State Tables

Grant Names

PP

TS1000

Software

Encoder

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

26

Update on Card

Just adding the updater...

Elect. Lock

Credential

System Code

User ID / TZ / Issue Date

Time Zones

Holidays

DST

Clock

State Table

Required Grant Name

Audit Trail

System Code

User ID

Act. / Exp. Date

Issue Date & Time

Given Grant Names

Software

System Code

Users

Doors

Time Zones

Matrix

State Tables

Grant Names

PP

TS1000

Software

Encoder

Updater

On Line

(TCP/IP)

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

27

Update on Card

Step 1

Credential

System Code

User ID

Act. / Exp. Date

Issue Date & Time

Given Grant Names

Revalidation

Software

System Code

Users

PP

TS1000

Software

Encoder

Updater

On Line

(TCP/IP) UpdaterEmbedded PC (TCP/IP Connection)

Reader

Data on CredentialActivation Date

Expiration Date

Given Grant Names

RevalidationNew feature to force the user to go to the Updater.

Optional for each user.

Revalidation Time defined for each user.

¡No need blacklist!

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

28

Update on Card

Step 2

Credential

Sector 1

System Code

User ID

Act. / Exp. Date

Issue Date & Time

Given Grant Names

Revalidation

PP

TS1000

Software

Encoder

Updater

On Line

(TCP/IP)

Audit TrailGet the User’s Audit Trail on the credential.

Capacity depends on Mifare Card.

Get the battery status on locks.

Elect. Lock

System Code

User ID / TZ / Issue Date

Time Zones

Holidays

DST

Clock

State Table

Required Grant Name

Audit Trail

Battery Status.

Sector 2

User’s Audit Trail

Battery Status

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

29

Update on CardStep 2

Credential

Sector 1

System Code

User ID

Act. / Exp. Date

Issue Date & Time

Given Grant Names

Revalidation

Memory Capacity1 Event = 8 Bytes.

Mifare 1k In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/Card) = 78 (Events/Card)

Mifare 4k In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/1k) = 78 (Events/1k)

In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 6 (Events/Sector) x 13 (Sector/1k) = 78 (Events/1k)

In 2k 15 (Block/Sector) x 16 (Bytes/Block) / 8 (Bytes/Event) = 30 (Events/Sector) x 8 (Sector/2k) = 240 (Events/2k)

78 (Events/1k) + 78 (Events/1k) + 240 (Events/2k) = 396 (Events/Card)

Options in the software:Decide how many sectors are going to be used to store the User’s Audit Trail.

When the selected memory capacity is full for each user we can decide:

•The card needs revalidation (to empty the memory)

•The last event delete the first one.

Sector 2

User’s Audit Trail

Battery Status

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

30

Update on CardStep 3

Credential

Sector 1

System Code

User ID

Act. / Exp. Date

Issue Date & Time

Given Grant Names

Revalidation

Modifications in Matrix

PP

TS1000

Software

Encoder

Updater

On Line

(TCP/IP)

Update LocksUpdate the user’s locking plan (Matrix) into the locks.

Add new users.

Elect. Lock

System Code

User ID / TZ / Issue Date

Time Zones

Holidays

DST

Clock

State Table

Required Grant Name

Audit Trail

Sector 2

User’s Audit Trail

Battery Status

1 Change

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

31

Update on Card

Step 3

Credential

Sector 1

System Code

User ID

Act. / Exp. Date

Issue Date & Time

Given Grant Names

Revalidation

Modifications in Matrix

Memory Capacity1 Change requires 4 Bytes.

Mifare 1k In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/Card) =156 (Change/Card)

Mifare 4k In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/1k) = 156 (Change/1k)

In 1k 3 (Block/Sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 12 (Change/Sector) x 13 (Sector/1k) = 156 (Change/1k)

In 2k 15 (Block/sector) x 16 (Bytes/Block) / 4 (Bytes/Change) = 60 (Change/Sector) x 8 (Sector/2k) = 480 (Change/2k)

156 (Change/1k) + 156 (Change/1k) + 480 (Change/2k) = 792 (Change/Card)

Options in the softwareDecide how many sectors are going to be used to update

the locking plan in the locks.

Sector 2

User’s Audit Trail

Battery Status

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

32

Update on Card

Step 4

Credential

Sector 1

System Code

User ID

Act. / Exp. Date

Issue Date & Time

Given Grant Names

Revalidation

Modifications in Locks

PP

TS1000

Software

Encoder

Updater

On Line

(TCP/IP)

Update Locks (On study...)Update:

Time Zones

Calendar (Holidays & DST)

State Table

Required Grant Name

Elect. Lock

System Code

User ID / TZ / Issue Date

Time Zones

Holidays

DST

Clock

State Table

Required Grant Name

Audit Trail

Sector 2

User’s Audit Trail

Battery Status

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

33

Update on Card

Updater

PP

TS1000

Software

Encoder

Updater

On Line

(TCP/IP)

Phase 1Embedded PC and reader in the same box.

Door Control in another box.

Door Control

Embedded

PC

Reader

Blocking

Device

Door

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

34

Update on Card

Updater

PP

TS1000

Software

Encoder

Updater

On Line

(TCP/IP)

Phase 2Embedded PC and door control in the same box.

Separate reader.

Reader

Embedded

PC

Door Control

Blocking

Device

Door

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

35

Update on Card

Updater

NetworkUnlimited number of Updaters

One Database Updater 1

Updater 2

Updater 3

Updater 4

Updater n

Database

Server

ETHERNET

TCP/IP

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths

36

ELECTRONIC LOCKELECTRONIC LOCK

Installation TemplateInstallation Template

System Integrators, Locksmiths

37

ELECTRONIC LOCKELECTRONIC LOCK

InstallationTemplateInstallationTemplate

System Integrators, Locksmiths

38

ELECTRONIC LOCKELECTRONIC LOCK

Installation TemplateInstallation Template

System Integrators, Locksmiths

39

ELECTRONIC LOCKELECTRONIC LOCK

Installation TemplateInstallation Template

SmartAir shileds SmartAir shileds

Outside shiled dimensions

40,5 x 281 x 10mm.

Inside shield dimensions

40,5 x 281 x 21mm.

Material

Stainless Steel

Lock mortise Lock mortise

Compatible with DIN and Scandinavian locksin different distancies.

Door width Door width

• From 38mm to 110mm door width. • The follower lock will have different lengths acc. to the door width. See the XLS file.• It´mandatory to provide the dimensions X and Y.

System Integrators, Locksmiths

40

ELECTRONIC LOCKELECTRONIC LOCK

System Integrators, Locksmiths