Upload
leona-golden
View
214
Download
0
Tags:
Embed Size (px)
Citation preview
1Division Appareillage et Système Résidentiels
1
IP SYSTEM
Wiring Devices and Home Systems Division
2Division Appareillage et Système Résidentiels
The reason of the system
3Division Appareillage et Système Résidentiels
House Building Compound
4000 units600m
4000 units1Km
2 wires digital system
8 wires + 2 wires digital system
IP + 2 wires digital system
LIMIT OF 2 WIRES:
4Division Appareillage et Système Résidentiels
The integration between 2wire and IP
THE IP TECHNOLOGY IS NOT A NEW SYSTEM, BUT IT ENTERS IN THE D.E.S. OFFER TO IMPROVE THE 2WIRES PERFORMANCE.
THIS INTEGRATION PERMITS TO TAKE ADVANTAGE OF BOTH TECHNOLOGIES:
•2wires technology
Easiness of cabling
Good ratio performace/price
Range of the internal/external units also
for the entry and medium segments
•IP technology
Distance
Multichannel
Centralization of the building’s management @
5Division Appareillage et Système Résidentiels
A tipical VDE system architecture can be divided in 2 lines:
Backbone
Riser
Typical building’s architecture
RIS
ER
BACKBONE
FLAT
Interface
BackboneRiserFlat
6Division Appareillage et Système Résidentiels
DISTANCE
Following these index, we can deduce that:
Backbone in the big residential complex, IP technology is the best solution
Riser 2wires responds to all requests
50m – 10Km
20
m –
60
0m
Distance
Usually with “distance” we mean the distance between the internal unit and the external unit, but it’s better to consider the average distance for every line:
Riser: from 5m to 600m
Backbone: from 50m to …Km
7Division Appareillage et Système Résidentiels
IP MULTICHANNELIn a big residential complex, the probability to have more than one call on the same line changes from line to line:
•Riser:low or medium probability
•Backbonehigh probability
The “multichannel” permits to have, on the same line, more A/V connections in the same time until 5 calls every 100 Mbits,
•the system is “always” available
Following these index, we can deduce that:
Backbone• in residential complex with many MAIN entries, the IP technology is the
best solution Riser
• the 2wires is able to respond to all the requests
2 4
6
high probability
low probability
medium probability
8Division Appareillage et Système Résidentiels
IP CENTRALIZATION OF BUILDING MANAGEMENT
DISTANCE AND MULTICHANNEL GIVE ALSO ANOTHER ADVANTAGE:
•Distance: in big residential complex it’s possible to collect all building information and functions in a single point•Multichannel: it’s possible manage all these information and functions in the same time
THEREFORE IT’S POSSIBLE TO CENTRALIZE THE MANAGEMENT OF ALL THE SYSTEM IN A SINGLE POINT: THE EVOLUTED SWITCHBOARD
•Communicate with all the external and internal units
•Management of all flat’s alarms
•Send messages to internal units
•Management by multi-switchboards
•Videocontrol
For management’s centralization we can consider the previous remarks: Backbone
• in residential complex with many Main entries, the IP technology is the best solution Riser
• in little and medium building the 2wires is able to respond to all the requests
9Division Appareillage et Système Résidentiels
New DES IP offer
10Division Appareillage et Système Résidentiels
The IP offer is composed by two devices: Interface 2 wires / IP
• Codes BT:346890 LG 574039
Switchboard software• Codes BT:346300 LG:574043
Two new codes Unlimited installation solutions
11Division Appareillage et Système Résidentiels
@
Cod: BT 346890 LG 574039
•2wires technology on the riser•IP protocol on the backbone•Dimension: 10 DIN•Two different modalities of configuration
•Simplified modalities by jumpers•Complete modalities by software
BT 346000 or 346020LG 063435
IP INTERFACE
12Division Appareillage et Système Résidentiels
•PC based solution ( Microsoft Windows )•Dedicated NETWORK•User-friendly menu interface available also for touchscreen display•Communication with internal units•Communication with external units•Communication between switchboards•Management by multi-switchboard•Flat alarms management•First level of videocontrol•Messages to Internal Units
Switchboard IP “software”
13Division Appareillage et Système Résidentiels
•Visualization of alarmstechnical alarm customization
•Visualization of switchboard’s messagesUp to five msgUp to 52 chrswithout occuping the VDE channel
14Division Appareillage et Système Résidentiels
•MANAGEMENT OF 8 SENSORS5 burglar sensors and 3 technical sensorsSensors direcly connected to alarm module
•PANIC ALARMone buttom insideexpandable with other buttons
•ALARMS SEGNALLINGVisualization on alarms module’s ledsVisualization on Internal Unit’s displayMailing to switchboards
•TWO MODELS: ALUMINIUM AND ANTHRACITE
•COMPACT DIMENSIONS:Flush-mounting installation in 506E box
All the axolute plates for 506E box
2wire
BT 349416-17
LG 573954
15Division Appareillage et Système Résidentiels
Details IP interface
16Division Appareillage et Système Résidentiels
CONNECTIONS:
1-ETH: Ethernet connection
2-SCS AV IN: Connection dedicated for the Entry Panels
3-SCS AV: System power supply (BUS) from the first power supply
4-SCS AV OUT: Connecton dedicated for the Internal Units
5-Connection for future use
6-DC: Device power supply (1&2) from the second power supply
7-USB port for configuration and reset button
8-LED
9-Physical configurator socket
Interface connection
17Division Appareillage et Système Résidentiels
LED of user interface
18Division Appareillage et Système Résidentiels
CONNECTION DIAGRAM
19Division Appareillage et Système Résidentiels
INTERFACE CONFIGURATION
The interface can be configured:
BY SOFTWARE (TiDeviceIP)
Via ETHERNET
Via USB (USB – mini usb)
WITH CONFIGURATORS
20Division Appareillage et Système Résidentiels
DIFFERENCE BETWEEN HARDWARE AND SOFTWARE CONFIGURATION
HW SW
MAX N° OF I.U. 4000 10000
MAX N° OF EP 16 1000
MAX N° OF SWITCHBOARD 9 UNLIMITED
DIRECT CALL FROM PE TO SB NO YES
REDIRECTION OF AUTO POWER ON NO YES
LIST OF CYCLING VIEW NO YES
21Division Appareillage et Système Résidentiels
The OFFSET concept:Max number of calls from EP=4000, max number of IU=4000, how can we go over this limit?
If in the IP interface we put something like the riser number in traditional system, we can go over! This is the OFFSET
The BASE address is the number that we add to the SCS number, and the result is the SYSTEM address.
22Division Appareillage et Système Résidentiels
Art. 346890 - AAdd. Base PE = 0Add. Base PI = 0Add. Base for Calls = 0(from 1 to 3999)
Art. 346890 - BAdd. Base PE = 0Add. Base PI = 0Add. Base for Calls = 4000(from 4000 to 7999)
Art. 346890 - CAdd. Base PE = 0Add. Base PI = 0Add. Base Call = 0(from 1 to 3999)
Art. 346890 - DAdd. Base PE = 0Add. Base PI = 4000(from 4000 to 7999)Add. Base Call = 0
ETHSWITCH
PE (A)P=1
PE (B)P=2
PI CONFIGURATION0..3999
PI CONFIGURATION0..3999
Using the software is possible to see all the interface/switchboard connected on the LAN (in automatical way) and configure them:
Set the range of EP and IU connected to each interface assigning them a system address
(System address = base address + SCS address)
Interface A: 1 PE conneced, base add of PE= 0 system add=SCS add PE=1
In this case the base add for calls is 0 (this EP will start to call from the system add 1-3999)
Interface B: 1 PE conneced, base add of PE= 0 system add=SCS add PE= 2
In this case the base add for calls is 4000 (this EP will start to call from the system add 4000-7999)
Interface C: 3999 PI connected,base add of PI =0 system add=SCS add PI= 1-3999
Interface D: 3999 PI connected, base PI add=4000 system add = 4000-7999
23Division Appareillage et Système Résidentiels
SWITCHBOARD FUNCTIONS:
CALLSCALLS
It is possible to receive the calls from the EP and IU
It is possible to call the IU and the EP
It is possible to forward calls from EP to IU
Intercom between different switchboards;
Is possible cycling the cameras deciding the order you want (system address: 1-30-45-245-567-ecc….)
TEXT MESSAGETEXT MESSAGE
Send text message to each switcboard; (max 150 c.)
Send text message to evoluted internal units (max 5 msg, 52 crts for each messagge);
ALARMSALARMS
The alarm message can be received just by the corrispondent switchboard..
The operator can manage the alarm (intrusion technical and antipanic) by the switchboard also calling the IU.
24Division Appareillage et Système Résidentiels
ANY QUESTIONS?