Upload
lee-richards
View
212
Download
0
Embed Size (px)
Citation preview
1
Data Plane Summary
Maarten Vissers2012-01-18
v1
2
Distributed Link Aggregation Data Plane Model
3
Link Aggregation
Link Aggregation Models – Partitioning
19.2/3/5
6.9, 9.5b
19.2
6.7
802.3
8.5
Agg
rega
tion
Con
trol Frame Collection
Control prsr/mux
Control prsr/mux
Control prsr/mux
Service Interface (UNITDATA)
Aggr prsr/mux
Aggr prsr/mux
Aggr prsr/mux
Marker Respndr
Frame Collctr
Frame Distribution
Frame Distrbtr
Marker Gen/Rec
DAS Frame Switching
Service Interface (UNITDATA)
19.2
6.7
802.3
19.2
6.7
802.3
19.2/3/5
6.9, 9.5b
19.2
6.7
802.3
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
8.6.3 MAC Relay
(EISS)(EISS)
LACPDU
Control prsr/mux
Control plane focussed 802.1AX stack Data plane focussed p802.1AXbq stack(partitioned Link Aggregation shim)
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
19.2
6.7
802.3
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
19.2
6.7
802.3
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS) (EISS)(EISS)
Example Server Layer
Alternatives:BVLAN,TESILSP, ODUk
Supports protected VLANs and unprotected VLANs
4
Link Aggregation server layers
19.2/3/5
6.9, 9.5b
19.2
6.7
802.3
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
8.6.3 MAC Relay
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS) (EISS)(EISS)
ODU Down MP
6.15
OTN Other
LSPDown MP
6.15
MPLS Other
VCnDown MP
6.15
SDH Other
6.14
6.10
6.14
6.11
19.2/5Link
TESI
LSP ODUk VC-n
Link Aggregation server layers for Intra-DAS (virtual) link
[Operator choice]
6.14
6.10
6.14
6.11
19.2/5
BVLAN
(ISS)
(ISS) (ISS) (ISS)
(ISS)
(ISS)
(ISS)
(ISS) (ISS)
Link Aggregation server layer
for ENNI link
5
ENNI DRNISVLAN MEP/MIP
Based on data plane model I in http://www.ieee802.org/1/files/public/docs2011/axbq-vissers-drni-data-plane-model-I-and-II-comparison-1011-v00.pptx
Characteristics are: Single hop ENNI MA NO MA end point on ENNI port
6
8.6.3 MAC Relay
Two Node Portal with 2 x 1 ENNIsNormal state, no failures
8.6.3 MAC Relay
19.2/3/5
6.9, 9.5b
Server Layer
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS)(EISS)
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
Server Layer
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS)(EISS)
Intra-DAS (virtual) Link
ENNI1 ENNI2
SVID=5 SVID=6
Active SVID=6 MEPs/MIPsStandby SVID=6 MEPs/MIPs
Active SVID=5 MEPs/MIPsStandby SVID=5 MEPs/MIPs
NO MEPSP MIP
ENNI MEP
7
8.6.3 MAC Relay
Two Node Portal with 2 x 1 ENNIsFailure of ENNI2 link
8.6.3 MAC Relay
19.2/3/5
6.9, 9.5b
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS)(EISS)
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS)(EISS)
Intra-DAS Link
ENNI1 ENNI2
SVID=5 SVID=6SVID=6
XDeactivate those SVID=6 MEPs/MIPsActivate those SVID=6 MEPs/MIPs
SVID=X (e.g. X=6) NO MEP function on ENNI1 and ENNI2 form one distributed NO MEP functionSVID=X (e.g. X=6) SP MIP function on ENNI1 and ENNI2 form one distributed SP MIP functionSVID=X (e.g. X=6) ENNI MEP function on ENNI1 and ENNI2 form one distributed ENNI MEP function
NO MEPSP MIP
ENNI MEP
Server LayerServer Layer
8
8.6.3 MAC Relay
Two Node Portal with 2 x 2 ENNIs
8.6.3 MAC Relay
19.2/3/5
6.9, 9.5b
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS) (EISS)(EISS)
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS) (EISS)(EISS)
Intra-DAS Link
ENNI1 ENNI3 ENNI2ENNI4
SVID=X (e.g. X=6) NO MEPs, SP MIPs, ENNI MEPs (one set will be active, others will be standby)
SVID=X (e.g. X=6) NO MEP function on ENNI1, ENNI2, ENNI3 and ENNI4 form one distributed NO MEP functionSVID=X (e.g. X=6) SP MIP function on ENNI1, ENNI2, ENNI3 and ENNI4 form one distributed SP MIP functionSVID=X (e.g. X=6) ENNI MEP function on ENNI1, ENNI2, ENNI3 and ENNI4 form one distributed ENNI MEP function
NO MEPSP MIP
ENNI MEP
Server LayerServer Layer
9
INNI DRNISVLAN MEP/MIP
Characteristics are: No need for NO MEP No need for ENNI MEP
10
8.6.3 MAC Relay
Two Node Portal with 2 x 1 INNIsNormal state, no failures
8.6.3 MAC Relay
19.2/3/5
6.9, 9.5b
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS)(EISS)
19.2/3/5
6.9, 9.5b
19.2
6.7802.3
Agg
rega
tion
Con
trol
Frame Collection
Marker Respndr
Frame Collector
Frame Distribution
Frame DistributorMarker
Gen/Rec
DAS Frame Switching
8.5
(EISS)
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
19.2/3/5
6.9, 9.5b8.5
LACPDU
Control prsr/mux
Marker
Aggrprsr/mux
(EISS)(EISS)
Intra-DAS Link
INNI1 INNI2
SVID=5 SVID=6
Active SVID=6 MIPStandby SVID=6 MIPs
Active SVID=5 MIPStandby SVID=5 MIPs
NO MIP
Intra-Carrier DRNI: INNI ports do not have to support SVLAN Up MEPs and SVLAN Down MEPs
Server LayerServer Layer
11
DNP Data Plane ModelsBVLAN, TESI, SVLAN MEP/MIP
Protection of EC groups BVLAN restoration via MSTP/MVRP TESI protection TESI segment protection Other server layer protection types
comparable with TESI protection and TEST segment protection
Protection of individual Ecs G.8031 EC SNCP (EC segment
protection)
12
Two Node Portal with BVLAN, TESI, SVLAN DNP
19.2/3/5
6.9, 9.5b
8.5
19.2
6.7
802.3
19.2/3/5
6.14
6.10
6.14
6.11, 9.5c
19.2/5
6.9
8.5
6.9
8.5
6.9
8.5
6.9
8.5
6.9
8.5
6.9
8.5
19.2/3/5
6.9, 9.5b
8.5
19.2
6.7
802.3
19.2/3/5
6.9, 9.5b
8.5
19.2
6.7
802.3
8.6.3 MAC Relay
8.6.3 MAC Relay
6.9
8.5
6.9
8.5
6.9
8.5
6.9
8.5
19.2/3/5
6.9, 9.5b
8.5
19.2
6.7
802.3
19.2/3/5
6.14
6.10
6.14
6.11, 9.5c
19.2/5
6.9
8.5
6.9
8.5
6.9
8.5
6.9
8.5
6.9
8.5
6.9
8.5
19.2/3/5
6.9, 9.5b
8.5
19.2
6.7
802.3
19.2/3/5
6.9, 9.5b
8.5
19.2
6.7
802.3
8.6.3 MAC Relay
8.6.3 MAC Relay
6.9
8.5
6.9
8.5
6.9
8.5
6.9
8.5
BVLAN or TESI
BV
LA
Nor
TE
SI B
VL
AN
or TE
SI
BVLAN
activ
e
bloc
ked
blocked
blocked
TESI
TE
SI T
ES
I
TESI
TE
SI T
ES
I