Upload
others
View
5
Download
1
Embed Size (px)
Citation preview
1
Contents
General Information About Us 2
Hydraulic Accessories
Filler breather (FBA) 3
Air breather (BH) 456
Tank connector for Air Beathers (TB)
Air Breathers with Spin on Cartridge (TS)Air Breathers with Splash Gaurd (FBP) 7
89
1011
Level Gauges (FLP)
Suction Strainer (FSS)
12
13 - 17
Suction Strainer (49)Suction Strainer (FES)
Power TransmissionAccessories
Oil Level Indicator (FKA)
Drain Plugs (DHA)18 - 22Breather Plugs (BHA)
23Spin - on filters (FFFL)Spin -On Filters
Inline filters (FIF) 27
Return Line Filters
Return Line filters (FRC) 30
35Clogging Indicators 32
Return Line filters (TTF)40Return Line filters (TTU)47By Pass Valves (BPV)
49High Pressure filters (FHP)535963
High Pressure Filters High Pressure filters (FMM)
High Pressure filters (FAP)High Pressure filters (FHM)
Pipe Clamps 69Pipe Clamps (FPC)
75Notes
Inline Filters
About UsFFP Products was established in 1968 with a small core team of young entrepreneurs with an engineering background willing to do something big in the field of engineering.Today with three generations of the family members and over 60 employees, We are leaders in manufacturing and supply of Hydraulic Filters, Hydraulic and Lubrication accessories in over 20 countries.
Since incorporation, we had the same goal. To deliver quality products at competitive prices.
Most of our products are interchangeable with leading suppliers, however we also design and built custom products as per our clients needs.
All our Products are designed and validated using latest CAD/CAM software’s and manufactured using latest CNC/VMC machines. Our In- House Laboratories keeps a constant check on all Technical parameters in line with International Standards.
We are an ISO 9001-2008 Certified Company.
2
Filler Breathers
FBATECHNICAL DATA:
Cap : Chrome plated steel.Lock and chains : Galvanized steel.Pressure valve : on request.Working temperature : -25 to +110Cseals : Rubberized cork.
FILTRATION :
Basket : Powder coated steel.Filtration : 40 microns foam.Celulose media : on request.
AIR FLOW RATES :
5 CFM & 25CFM.
D1
D2
D3
H1
H2
D4 x n holes
DIMENSIONS OPTION ‘L’ OPTION ‘P’ MOUNTING HOLES
D5
D6
HYDRAULIC ACCESSORIES
FBA5F40
FBA5F10
FBA25F40
FBA25F10
FBA25F40L148
FBA25F10L148
FBA25F40L100
FBA25F10L100
40
10
40
10
40
10
40
10
150
300
450
750
450
750
450
750
47
47
80
80
80
80
80
80
29
29
50
50
50
50
40
40
52
52
83
83
83
83
83
83
Filtr. μ Flow rate (l/min)
M5
M5
M5
M5
M5
M5
M5
M5
D4 H2
64
64
78
78
148
148
100
100
3
3
6
6
6
6
6
6
holes n°
31
31
52
52
52
52
52
D5
41
52
41
73
73
73
73
73
D6
73
H1
48
48
57
57
57
57
57
57
D3D2D1Part No.
Padlock holder version Pressurization valve (0.35 bar)
All
dim
ensi
ons
are
in m
m o
r oth
erw
ise s
tate
d
3
Air Breathers
BHTECHNICAL DATA:
Cap : Chrome plated steel.Connector : Galvanized steel.Pressure valve : on request.Working temperature : -25 to +110CSeals : Nitrile ( buna N ).
FILTRATION :
Filtration : 40 microns foam.Celulose media : on request.
AIR FLOW RATES :
5 CFM & 25CFM.
D1
H1
H2
H3
D2
HEX
PRESSURIZED VERSIONADD ‘P’ AT END OF PART NO
BH 6
BH 8
BH 10
BH 12
BH 16
10
10
10
10
10
150
300
450
750
850
47
47
76
76
76
1/4” BSP
3/8” BSP
½” BSP
3/4” BSP
1” BSP
19
19
35
35
38
Filtr. μ Flow rate (l/min)
45
45
66
66
66
Spare H1 element
-
-
-
-
12
12
12
16
16
H2
7
7
7
7
7
H3 kg
-
-
-
-
All
dim
en
sio
ns
are
in m
m o
r o
the
rwis
e s
tate
d
HYDRAULIC ACCESSORIES
Part No.
- -
BH 6N
BH 8N
BH 10N
BH 12 N
BH 16N
10
10
10
10
10
150
300
450
750
850
47
47
76
76
76
1/4” NPT
3/8” NPT
½” NPT
3/4” NPT
1” NPT
19
19
35
35
38
45
45
66
66
66
-
-
-
12
12
12
16
16
7
7
7
7
-
-
-
-
- -
D1 D2
7 -
4
Tank connector for Air Beatherswith Spin on Cartridge TB
MATERIAL :
Mild Steel Zinc plated
Cartridge can:
Mild Steel
Filter media:
CL =CelluloseIF = Inorganic fiber
Filtration degree (in air): 3μm
COMPATIBILITY :
Full with fluids HH - HL - HM - HR - HV - HG
(according to ISO 6743/4).
WORKING TEMPERATURE
From -25°C to 110°C
FTB02FFC
FTB03FFC
FTB04FFC
FTB01FFW
FTB02FFW
FTB03FFW
FTB04FFW
1
1
1
1
2
2
2
2
1.800
1.800
2.800
2.800
1.800
1.800
2.800
2.800
96
96
129
129
96
96
129
129
146
191
181
226
146
191
181
226
201
246
236
281
204
249
239
Dwg. A
284
Flow rate (l/min)
3/4” BSP
3/4” BSP
1 1/4” BSP
1 1/4” BSP
3/4” BSP
3/4” BSP
1 1/4” BSP
1 1/4” BSP
C Spare cartridge
18
18
32
32
18
18
32
D1
32
32
48
48
-
-
-
D2
40
-
40
40
40
40
40
40
40
R
FSE01N
FSE02N
FSE03N
FSE04N
FSE01N
FSE02N
FSE03N
Cellulose = CL
FSE04N
Inorganic fiber = IF
HYDRAULIC ACCESSORIES
B D
All
dim
en
sio
ns
are
in m
m o
r o
the
rwis
e s
tate
d
FTB01FFC
Part No.
RA
B
D
55
D1D2
8
58
D1
52 41
6
120
60
6
73 83
WELD CONNECTOR
FLANGED CONNECTOR
DRG 1 DRG 2
32
C
5
Air Breathers with Spin on Cartridge TS
MATERIALS
Adaptor: zinc plated steel
Basket: zinc plated steel
Cartridge can: steel
Filter media:
CL =Cellulose
IF = Inorganic fiberFiltration degree (in air): 3μm
COMPATIBILITY
Full with f uids HH - HL - HM - HR - HV - HG (according to ISO 6743/4).
WORKING TEMPERATURE
From -25°C to 110°C
52
73
M5
A
B
C
192
148
181
171
50
FLOW FLUID POWER
FTS01FWC
FTS03FWC
1.800
2.800
95
129
145
181
A BFlow rate (l/min)
3/4” BSP
1 1/4” BSP
C Spare cartridge
FSE01N
Cellulose = CL
FSE03N
Inorganic fiber = IF
HYDRAULIC ACCESSORIES
All
dim
ensi
ons
are
in m
m o
r ot
herw
ise
stat
ed
6
Air Breathers with Splash Gaurd FBP
MATERIALS
Body: Polyamide 66
Basket: Powder Coated Steel
Filter media:
CL =Cellulose
IF = Inorganic fiberFiltration degree (in air): 25μm
COMPATIBILITY
Full with f uids HH - HL - HM - HR - HV - HG (according to ISO 6743/4).
WORKING TEMPERATURE
From -25°C to 110°C
FPBA2510
FPBA2525
50
50
118
118
145
145
A BFlow rate (CFM)
47
47
C Spare cartridge
FPBA25E10
FPBA25E25
HYDRAULIC ACCESSORIES
All
dim
ensi
ons
are
in m
m o
r ot
herw
ise
stat
ed
10μ
25μ
A
B
C
FilterationPart No
7
Level Gauges
FLPTECHNICAL DATA:
Cover : Powder coated steel.Tube : Transparent poly carbonate.Bolts & nuts : Galvanized steel.Working temperature : -25 to +100CMax. Tightening torque : 10 Nm.Seals : Nitrile ( buna N ).
OPTIONAL :
Black screen : for white liquid.Bolt Size : 10 mm & 12 mm.Thermometer : 0 to 100 CRed float : for transparent liquid.
STOCK SIZES :
3”, 5” & 10” C to C..
FLP3
FLP3T
FLP5
FLP5T
108
108
160
160
76
76
127
127
32
32
78
78
M10
M10
M12
M12
H1 H3H2
35
35
35
35
E1
24
24
24
24
E2
50
50
50
50
HYDRAULIC ACCESSORIES
Part No. D E3A
ll dim
ensi
ons
are
in m
m o
r oth
erw
ise s
tate
d
C F
FLP10
FLP10T
286 254 202 M12 35 24 50
286 254 202 M12 35 24 50
80-70-60-50-40-30-20-
-180-160-140-120-100-80-60
FLOW FLUID POWER
H1H2H3
D
E1 E2E3
17
85
8
Suction Strainers
FSSTECHNICAL DATA:
End cap : galvanized steel.Center tube : galvanized steel.Head : Die cast alluminium.Head ( optional ) : galvanized steelBy-pass : on request.Permanent magnet : on requestWorking temperature : -25 to +110 C
FILTRATION :
Wire mesh : Stainless steel.Filtration : 149 microns (100 mesh).Celulose media : on request.Other ratings : on request.
STOCK SIZES :
3/8” BSP TO 3” BSP.
FLOW RATES :
12 L/min to 600 L/min.
MODEL NO.
FSS - 003 12
FLOW
LPM
THREADIN. BSP
A
LENGTH
B
OVERALLLENGTH
C
DIA
D
SCREENAREA
(SQ. CMS.)
3/8” 78 90 46 190
FSS - 005 20 1/2” 93 105 46 258
FSS - 007 28 3/4" 97 109 64 105
FSS - 010 40 1" 127 139 64 545
FSS - 015 60 1 1/4” 127 139 84 930
FSS - 020 80 1 1/2" 156 168 84 1170
FSS - 030 120 1 1/2" 188 200 84 1450
FSS - 040 160 2" 223 235 100 1935
FSS - 050 200 2" 248 260 100 2195
FSS - 075 300 2 1/2" 199 211 145 2790
FSS - 100 400 3" 260 272 145 3700
FSS - 150 600 3" 333 345 145 5900 All d
imensio
ns a
re in m
m o
r oth
erw
ise s
tate
d
A
B
C
D
9
Suction Strainers
49TECHNICAL DATA:
End cap : Galvanized steel.Center tube : Galvanized steel.Head : Galvanized steel.Head ( optional ) : Nylon ( polyamide 66)By-pass : Add R3 or R5Permanent magnet : on requestWorking temperature : -25 to +110 C
FILTRATION :
Wire mesh : Stainless steel.Filtration : 149 microns (100 mesh).Celulose media : on request.Other ratings : on request.
STOCK SIZES :
3/8” NPT TO 3” NPT
FLOW RATES :
3 GPM to 100GPM.
A
B
C
D
(NPT)
10
Suction Strainers
FESTECHNICAL DATA:
End cap : galvanized steel.Center tube : galvanized steel.Head : cast iron bushing.By-pass : on request.Permanent magnet : on requestWorking temperature : -25 to +110C
FILTRATION :
Wire mesh : Stainless steel.Filtration : 149 microns (100 mesh.)Celulose media : on request.Other ratings : on request.
STOCK SIZES :
1” NPT TO 4” NPT.
FLOW RATES :
5 GPM to 100 GPM.
Part No.FlowGpm
Threads (NPT)
C D E
Filterationarea (sq.in)
A B
FES05
FES10
FES15
FES25
FES50
FES100
005
010
015
025
050
100
1”
11/4”
11/2”
2”
3”
4”
½”
3/4”
1”
11/4”
2”
3”
136
207
209
230
246
287
27
31
31
34
43
46
30
34
42
54
76
101
35
64
86
125
260
315
To order with By-pass valve add R3 or R5 ahead of part no.
D
B C
E
A
11
Oil Level Indicators
FKATECHNICAL DATA:
M.O.C : Extruded aluminium.Glass/Polycarbonate,Reflector : Anodized Aluminium.Seals : NBRMax pressure : 1.5 Bar
OPTIONAL :
High Pressure.Threads on request.
STOCK SIZES :
1/4" BSP/NPT TO 2" BSP/NPTM12 TO M48
PART NO
FTLAN1GFTLA2GFTLA3GFTLA4GFTLA5GFTLA6GFTLA7GFTLA8G
THREADS
1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”
f
89
101114151517
t
7799
10101014
e
1722273240505570
v
1013162127374050
PART NO
FTLAN1MFTLA2MFTLA3MFTLA4MFTLA5MFTLA6MFTLA7MFTLA8MFTLA9MFTLA10MFTLA11MFTLA12MFTLA13MFTLA14MFTLA15MFTLA16MFTLA17MFTLA18MFTLA19M
THREADS
M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 1.5M24 x 2
M25 x 1.5M27x 1.5M30 x 1.5M30 x 2
M33 x 1.5M33 x 2
M35 x 1.5M40 x 1.5M42 x 3M48 x 3M60 x 2M60 x 4
f
899
10101111111111111414141215151717
t
77779999999
1010101010101414
e
17222224273030323236364040405050557070
v
10131316161616212121212727273737405050
12
DRAIN PLUGS
DHAFTCF/F SERIES BREATHER PLUG
SPECIFICATION
Head milling for greater sealing area against the crankcase.Hole for venting internal pressure.
APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For application requiring normal tight sealing.
PART NO
FTCF/F0GFTCF/F1GFTCF/F2GFTCF/F3GFTCF/F4GFTCF/F5GFTCF/F0MFTCF/F1MFTCF/F2MFTCF/F3MFTCF/F4MFTCF/F5M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
M10 x 1M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5
d
142022283240142022262828
t
7889
10.510.5
788899
e
101718222734101718202222
FTMV SERIES BREATHER PLUG
SPECIFICATION
Breather plug with O-ring and external valveSet at 0.10 to 0.15 bar.Opens at intervals and vents internal pressure.
APPLICATION
For use to keep out foreign bodies.Holding the fluid when machine is turned upside down during shipment.For use in differentials, transmission and small speedreducers.
DIMENSIONS:
f
8891112
12.588991111
PART NO
FTMV0GFTMV1GFTMV2GFTMV3GFTMV4GFTMV5GFTMV0MFTMV1MFTMV2MFTMV3MFTMV4MFTMV5MFTMV6M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
M10 x 1M12 x 1.5M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5
t
5677885667777
e
14172227324014171722222427
DIMENSIONS:
f
88
10101214888
10101010
13
DRAIN PLUGS
DHA
FTCEM SERIES DRAIN PLUG
Tampered, Hardened alloy.Permanent magnet insert of special alloy.Available with metal washers only.
APPLICATION
For high tight sealing.For high rpm machinery.
PART NO
FTCEM0GFTCEM1GFTCEM2GFTCEM3GFTCEM4GFTCEM5GFTCEM6GFTCEM7GFTCEM8GFTCEM0MFTCEM1MFTCEM2MFTCEM3MFTCEM4MFTCEM5MFTCEM6MFTCEM7MFTCEM8MFTCEM9MFTCEM10MFTCEM11MFTCEM12MFTCEM13M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M10 x 1
M12 x 1.5M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 1.5M24 x 2
M26 x 1.5M27 x 2
M30 x 1.5M30 x 2M33 x 2
e
568
10121722243256688
101012121212171717
g
5556
1010151515555566666
1010101010
f
812121416161616208
12121212141414141616161616
h
455566
10101544555555566666
SPECIFICATION
t
33344555533333444444445
d
1418222632404955681417192123252729293232363640
FTSC/F SERIES DRAIN PLUG
SPECIFICATION
Threaded plug with Flanged head forextra tight tightening.Head milling produces crown for extra tight sealing.
APPLICATION
For application requiring extral tight sealing.For use in dusty enviroment and hydraulic units.Resistance to twisting and overheated atmosphere.
PART NO
FTC/F0GFTC/F1GFTC/F2GFTC/F3GFTC/F4GFTC/F5GFTC/F0MFTC/F1MFTC/F2MFTC/F3MFTC/F4MFTC/F5M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
M10 x 1M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5
d
142022283240142022262828
t
7889
10.510.5
788899
e
101718222734101718202222
f
8891112
12.58899
1011
14
DRAIN PLUGS
DHA
FTSCM/F SERIES DRAIN PLUG
FTSCM SERIES DRAIN PLUG
Tampered, Hardened alloy.Permanent magnet insert of special alloy.Available with metal washers only.
APPLICATION
For high tight sealing.For high rpm machinery.
PART NO
FTSCM0GFTSCM1GFTSCM2GFTSCM3GFTSCM4GFTSCM5GFTSCM6GFTSCM7GFTSCM8GFTSCM0MFTSCM1MFTSCM2MFTSCM3MFTSCM4MFTSCM5MFTSCM6MFTSCM7MFTSCM8MFTSCM9MFTSCM10MFTSCM11MFTSCM12M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M10 x 1
M12 x 1.5M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2M30 x 2M33 x 2M42 x 3M48 x 3M60 x 4
e
14172227324050557014171722222427303640505570
g
5568
10151515155556688
101015151515
f
88
10101214151517888
10101010121214151517
h
6668
10151515156666688
101015151515
SPECIFICATION
t
567788
1010125667777888
101012
PART NO
FTSCM/F0GFTSCM/F1GFTSCM/F2GFTSCM/F3GFTSCM/F4GFTSCM/F5GFTSCM/F0MFTSCM/F1MFTSCM/F2MFTSCM/F3MFTSCM/F4MFTSCM/F5MFTSCM/F6MFTSCM/F7MFTSCM/F8M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
M10 x 1M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2M30 x 2M33 x 2
e
101418222734101418182022243034
g
5556
10105555668
1010
f
8891112148899
1011121214
h
445667445566667
t
8889
10.510.5
8889999
10.510.5
d
141822283240141822242628303840
Tampered, Hardened alloy.Head milling produces crown with greater sealing area.Permanent magnet insert of special alloy.Available with metal washers only.
APPLICATION
For high tight sealing.For high rpm machinery.
SPECIFICATION
15
DRAIN PLUGS
DHAFTC/Z SERIES DRAIN PLUG
SPECIFICATION
Knurled Head for hand tightening.APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For application requiring less tight fitting.
PART NO
FTC/Z0GFTC/Z1GFTC/Z2GFTC/Z3GFTC/Z4GFTC/Z5GFTC/Z6GFTC/Z7GFTC/Z8GFTC/Z0MFTC/Z1MFTC/Z2MFTC/Z3MFTC/Z4MFTC/Z5MFTC/Z6MFTC/Z7MFTC/Z8M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M10 x 1
M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2M30 x 2M33 x 2
h
121212152020202020121212121515152020
d
202226304045555570202226263030364245
f
88
1010121415151788
10101010121214
FTCE SERIES DRAIN PLUG
SPECIFICATION
Socket head for extra tightening.Tampered, Hardened light alloy.Available with metal washer only.
APPLICATION
For application requiring tight sealing.Fou use in dusty enviroment and hydraulic units.
extra
PART NO
FTCE0GFTCE1GFTCE2GFTCE3GFTCE4GFTCE5GFTCE6GFTCE7GFTCE8GFTCE0MFTCE1MFTCE2MFTCE3MFTCE4MFTCE5MFTCE6MFTCE7MFTCE8MFTCE9MFTCE10MFTCE11MFTCE12MFTCE13M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M10 x 1
M12 x 1.5M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 1.5M24 x 2
M26 x 1.5M27 x 2
M30 x 1.5M30 x 2M33 x 2
d
1418222632404955681417192123252729293232363640
t
33344555533333444444445
e
568
10121722243256688
101012121212171717
f
812121416161616208
12121212141414141616161616
16
DRAIN PLUGS
DHA
FTC SERIES DRAIN PLUG
SPECIFICATION
Hex head for tight sealing.Maximum resistance for twisting and overheating.
APPLICATION
For application requiring extra tight fitting.For all general purpose sealing.
PART NO
FTC0GFTC1GFTC2GFTC3GFTC4GFTC5GFTC6GFTC7GFTC8GFTC0MFTC1MFTC2MFTC3MFTC4MFTC5MFTC6MFTC7MFTC8MFTC9MFTC10MFTC11MFTC12M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M10 x 1
M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2
M26 x 1.5M30 x 2M33 x 2M42 x 3M48 x 3M60 x 4
t
567788
1010125677778888
101012
e
14172227324050557014172222242730323640505570
f
88
1010121415151788
1010101012121214151517
FTSC SERIES DRAIN PLUG
SPECIFICATION
Hex head for tight sealing.Maximum resistance for twisting and overheating.
APPLICATION
For application requiring extra tight fitting.For all general purpose sealing.
PART NO
FTSC0GFTSC1GFTSC2GFTSC3GFTSC4GFTSC5GFTSC6GFTSC7GFTSC8GFTSC0MFTSC1MFTSC2MFTSC3MFTSC4MFTSC5MFTSC6MFTSC7MFTSC8MFTSC9MFTSC10MFTSC11MFTSC12M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M10 x 1
M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2
M26 x 1.5M30 x 2M33 x 2M42 x 3M48 x 3M60 x 4
t
567788
1010125677778888
101012
e
14172227324050557014172222242730323640505570
f
88
1010121415151788
1010101012121214151517
17
BREATHER PLUGS
BHA
FTCF/Z SERIES BREATHER PLUG
SPECIFICATION
Threaded plug with knurled round head forhand tightening.Hole for venting internal pressure.
APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For application requiring normal tight sealing.
PART NO
FTCF/Z0GFTCF/Z1GFTCF/Z2GFTCF/Z3GFTCF/Z4GFTCF/Z5GFTCF/Z6GFTCF/Z7GFTCF/Z8GFTCF/Z0MFTCF/Z1MFTCF/Z2MFTCF/Z3MFTCF/Z4MFTCF/Z5MFTCF/Z6MFTCF/Z7MFTCF/Z8M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M10 x 1
M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2M30 x 2M33 x 2
h
121212152020202020121212121515152020
f
88
1010121415151788
10101010121214
d
202226304045555570202226263030364245
FTCF SERIES BREATHER PLUG
SPECIFICATION
Hole for venting internal pressure.
APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For application requiring normal tight sealing.
PART NO
FTCF0GFTCF1GFTCF2GFTCF3GFTCF4GFTCF5GFTCF6GFTCF7GFTCF8GFTCF0MFTCF1MFTCF2MFTCF3MFTCF4MFTCF5MFTCF6MFTCF7MFTCF8MFTCF9MFTCF10MFTCF11MFTCF12M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M10 x 1
M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2
M26 x 1.5M30 x 2M33 x 2M42 x 3M48 x 3M60 x 4
t
567788
1010125677778888
101012
f
88
1010121415151788
1010101012121214151517
e
14172227324050557014172222242730323640505570
DIMENSIONS:
DIMENSIONS:
18
BREATHER PLUGS
BHA
FTCFS SERIES BREATHER PLUG
SPECIFICATION
Hex head and spherical bronze filter.Filtration of 40 microns.
APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For application running in dusty enviromentand very small ecumbarance.
PART NO
FTCS1GFTCS2GFTCS3GFTCS4GFTCS5GFTCF1MFTCF2MFTCF3MFTCF4MFTCF5M
THREADS
1/4”3/8”1 /2”3/4”1”
M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5
t
6778867777
e
17222732401722222427
DIMENSIONS:
f
89
121416899
1212
FTCSF/Z SERIES BREATHER PLUG
PART NO
FTCSF/Z1GFTCSF/Z2GFTCSF/Z3GFTCSF/Z4GFTCSF/Z5GFTCSF/Z6GFTCSF/Z7GFTCSF/Z8GFTCSF/Z1MFTCSF/Z2MFTCSF/Z3MFTCSF/Z4MFTCSF/Z5MFTCSF/Z6MFTCSF/Z7MFTCSF/Z8M
THREADS
1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2M30 x 2M33 x 2
h
12121520202020201212121515152020
f
81012
13.5141616178
10101212
13.51414
d
22263040455555702226263030364245
DIMENSIONS:
SPECIFICATION
Threaded plug with knurled round head forhand tightening.Spherical bronze filter.Filteration of 40 microns.
APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For application requiring normal tight sealing.Fou use in dusty enviroment and hydraulic units.
19
BREATHER PLUGS
BHA
FTSFO/R SERIES BREATHER PLUG
SPECIFICATION
Galvanized steel cover.Large internal chamber with o-ring.
APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For use in agricultural and earth moving m/c.For use where strong sloshing of fluids.
PART NO
FTSFO/R0GFTSFO/R1GFTSFO/R2GFTSFO/R3GFTSFO/R4GFTSFO/R5GFTSFO/R0MFTSFO/R1MFTSFO/R2MFTSFO/R3MFTSFO/R4MFTSFO/R5M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
M10 x 1M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5
d
212124303038212124303030
h
212123262429212123262626
e
171720273240171720272727
DIMENSIONS:
f
889
101214889
101010
FTSS SERIES BREATHER PLUG
SPECIFICATION APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For application requiring normal tight sealing.Fou use in speed shift gears,agricultural over gears and speed reduction gear boxes..
Galvanized steel cover.Large internal chamber with o-ring.Pressure valve set at 0.05 to 0.10 bar.
PART NO
FTSS0GFTSS1GFTSS2GFTSS3GFTSS4GFTSS5GFTSS0MFTSS1MFTSS2MFTSS3MFTSS4MFTSS5MFTSS6MFTSS7MFTSS8M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
M10 x 1M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2M30 x 2M33 x 2
d
16.516.522263038
16.516.522222426303038
h
161719202429161719192020242529
e
141722273240141722222427303640
DIMENSIONS:
f
89111112148911111111121414
20
BREATHER PLUGS
BHA
FTSF SERIES BREATHER PLUG
SPECIFICATION
Galvanized steel cover.Large internal chamber with o-ring.Spherical bronze filter of 40 microns filteration.
APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For use in dusty enviroment and hydraulic units and cylinders.
PART NO
FTSF1GFTSF2GFTSF3GFTSF4GFTSF5GFTSF6GFTSF7GFTSF8GFTSF1MFTSF2MFTSF3MFTSF4MFTSF5MFTSF6MFTSF7MFTSF8MFTSF9MFTSF10MFTSF11M
THREADS
1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2M30 x 2M33 x 2M42 x 3M48 x 3M60 x 4
d
16.522263038505570
16.522222426303038505570
h
17192124293335401719192121242529333540
e
17222732405055701722222427303640505570
f
8101214161616168
10101212121416161616
FTSFA SERIES BREATHER PLUG
SPECIFICATION APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For application requiring normal tight sealing.Fou use in motor fields.
Galvanized steel cover.Large internal chamber with o-ring.Spherical bronze filter of 40 microns filtration.
PART NO
FTSFA0GFTSFA1GFTSFA2GFTSFA3GFTSFA4GFTSFA5GFTSFA0MFTSFA1MFTSFA2MFTSFA3MFTSFA4MFTSFA5MFTSFA6MFTSFA7MFTSFA8MFTSFA9M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
M10 x 1M12 x 1.5M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 1.5M26 x 1.5M30 x 1.5
d
16.516.522263038
16.516.516.522222426303030
h
16171920242916171719192020242425
e
14172227324014171722222427303236
DIMENSIONS:
f
881111121488811111111121214
21
BREATHER PLUGS
BHA
FTSFT/N SERIES BREATHER PLUG
SPECIFICATION
Galvanized steel cover.Large internal chamber with labyrynth andperpendicular cut.No oil spattering.
APPLICATION
For use only on upper cranckcase and awayfrom moving parts.For use in dusty enviroment and reduction gears,geared motors, speed variators and gearshift boxes.
PART NO
FTSFT/N1GFTSFT/N2GFTSFT/N3GFTSFT/N4GFTSFT/N5GFTSFT/N6GFTSFT/N7GFTSFT/N8GFTSFT/N1MFTSFT/N2MFTSFT/N3MFTSFT/N4MFTSFT/N5MFTSFT/N6MFTSFT/N7MFTSFT/N8MFTSFT/N9MFTSFT/N10MFTSFT/N11M
THREADS
1/4”3/8”1 /2”3/4”1”
1.1/4”1.1/2”
2”M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5M24 x 2M30 x 2M33 x 2M42 x 3M48 x 3M60 x 4
d
16.522263038505570
16.522222426303038505570
h
23292935434546462329292929354243454646
e
17222732405055701722222427303640505570
f
89
101214151517899
1010121214151517
FTC/F SERIES DRAIN PLUG
SPECIFICATION
Threaded plug with Flanged head forextra tight tightening.Head milling produces crown for extra tight sealing.
APPLICATION
For application requiring extral tight sealing.For use in dusty enviroment and hydraulic units.Resistance to twisting and overheated atmosphere.
PART NO
FTC/F0GFTC/F1GFTC/F2GFTC/F3GFTC/F4GFTC/F5GFTC/F0MFTC/F1MFTC/F2MFTC/F3MFTC/F4MFTC/F5M
THREADS
1/8”1/4”3/8”1 /2”3/4”1”
M10 x 1M14 x 1.5M16 x 1.5M18 x 1.5M20 x 1.5M22 x 1.5
d
142022283240142022262828
t
7889
10.510.5
788899
e
101718222734101718202222
f
8891112
12.58899
1011
22
SPIN -ON FILTERS
FHFL
MATERIALS
Head:Aluminium alloy
Spin-on cartridge:Steel
Bypass valve:Polyammide
Seals:NBR Nitrile
Indicator housing:Brass
PRESSURE (ISO 10771-1:2002)
Max working:1,2 MPa (12 bar)
Test:1,5 MPa (15 bar)
Bursting:2,5 MPa (25 bar)
Collapse, differential for the fi lter element (ISO 2941): 400 kPa (4 bar)
WORKING TEMPERATURE
From -25° to +110° C
BYPASS VALVE
Setting:35 kPa (0,35 bar) ± 10%
COMPATIBILITY (ISO 2943:1999)
Full with fl uids: HH-HL-HM-HV-HTG(according to ISO 6743/4)
23
SPIN -ON FILTERS
FHFL
SPIN ON FILTER HOUSING
kg
FHFL11
FHFL12
FHFL21
FHFL31
3/4”
3/4”
1” 1/4
1” 1/2
3/4” BSP
3/4” BSP
1” 1/2 16-UN
1” 1/2 16-UN
-
-
1” 1/4 BSP
1” 1/4 BSP
96
96
129
129
96
96
134
-
M8
M8
M8
M10
95
95
133
-
20,5
20,5
35
-
7
7
10
-
20
20
30
-
49
49
64
-
38
38
50
-
37
37
57
-
1.2
1.5
1.9
3.5
D1 D3 D4 D5 D6 E E1 E2 E3 E4 E5 E6D2
145 188 208
191
181
181
234
248
216
254
278
246
H1 H2 H3
H3
62
1/8
” B
SP
H2
72 55
ø D
6ø D4
H3
H2
H1
145
ø D2
ø D3
80
ø D
1
EE1 E1
D2
D3
D4
H3 H2
D1
E2 D
1 E3
E3
H1
ø D
6E
5
1/8"
E6
E4
ø D
5
FHFL11 & FHFL12 FHFL21 & FHFL31
24
FILTER HOUSING PRESSURE DROP
Δp (bar)
0,01
0,02
0,03
0,04Δp (kPa)
25
FHFL
0 50 100 125 150
1
2
3
4
l/min75
3/4"
Δp (bar)
0,2
0,4
0,6
0,8Δp (kPa)
15
FHFL11&FHFL12
0 30 60 75 90
20
40
60
80
l/min45
Δp (bar)
0,2
0,4
0,6
0,8Δp (kPa)
25
FHFL2+& FHFL3+
0 50 100 125 150
20
40
60
80
l/min75
The “Assembly Pressure Drop (∆p)” is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than 3 kPa (0,03 bar).
BYPASS VALVE PRESSURE DROP
PRESSURE DROP CURVES (∆p)
N.B. All the curves have been obtained with mineral oil having a kinematic viscosity 30 cSt and specifi c gravity 0,9 kg/dm3; for fl uids with different features,
CLEAN FILTER ELEMENTPRESSURE DROP
WITH C+ AND M+ MEDIA
Δp (bar)
0,01
0,02
0,03
0,04Δp (kPa)
25
FHFLE21
0 50 100 125 150
1
2
3
4
l/min75
CC CDME
MF
Δp (bar)
0,01
0,02
0,03
0,04Δp (kPa)
10
FHFLE11
0 20 40 50 60
1
2
3
4
l/min30
CC CD ME MF
∆ ∆Δp (bar)
0,01
0,02
0,03
0,04Δp (kPa)
10
FHFLE12
0 20 40 50 60
1
2
3
4
l/min30
CC CDME
MF
1” 1/4
1” 1/2
SPIN -ON FILTERS
FHFL
25
FILTER ELEMENT2Area (cm )
Media M+A
Media C+B C
FHFLE11
FHFLE12
FHFLE21
FHFLE22
96,5
96,5
129
129
3/4” BSP
3/4” BSP
1” 1/4 BSP
1” 1/4 BSP
146
191
181
226
980
1.390
1.940
2.570
3.305
4.745
5.560
7.360
C
B
A
kg
0,70
0,80
1,20
1,40
10 = vacuum gauge, bottom connection
06 = 1/8" seat, plugged
CLOGGING INDICATOR
FAMILYNOMINAL SIZE & LENGTH
F LH FAMILYSIZE & LENGTH
ELEMENT E
H F L
PORT TYPE
B = BSP thread
F = SAE flange 3000 psi, metric screws
PORT SIZE (quote "D1")
06 = 3/4
10 = 1" 1/4
12 = 1" 1/2
BYPASS VALV E
W = without
A = 35 kPa (0,35 bar)
F = FKM
N = NBR
SEALSSEALS
FILTER MEDIACC = cellulose 10
CD = cellulose 25CC = cell. 10
CD = cell. 25
FILTER MEDIA
91 91 9191 = SPDT, vacuum switch
F = FKM Fluoroelastomer
N = NBR Nitrile
06 06 06
B = FILTER HOUSING
F = FILTER COMPLETE
TYPE
F
B
F
B
F
B
-
10
-
06
-
-
06
-
-
- - - -
ME = metal wire mesh 60
MF = metal wire mesh 90
m
m MF = w. mesh 90 m
ME = w. mesh 60 m
m
>2
>2
mm
m
PART NO
91
06
F
B
-
-
12
SPIN -ON FILTERS
FHFL
26
Inline filter
FIF
Max working:2 MPa ( 20 bar )
Test:3 MPa ( 30 bar )
Bursting:4 MPa ( 40 bar )
BYPASS VALVE
170 kPa (1.7 bar)+/- 10%
WORKING TEMPERATURE
From -25° to +110° C
COMPATIBILITY
Full with fl uids: HH-HL-HM-HR-HV-HG
MATERIALS
Head:Die cast alluminum alloy
Bowl:Die cast alluminium alloy
Seals:Nitrile ( buna n)
Indicator housing:Brass
PRESSURE
A visual clogging indicator allows monitoring of the element condition and provides maximum
by indicating the exact time for the element replacement.
VISUAL CLOGGING INDICATOR
element life
F80-F81 Fp1F32
27
FIF
Inline filter
H1
H2
H3
H4
H5
H6
G1
G2
PART NO PORTG1
D1
D1 H1 H2 H3 H4 H5 H6 G2
FILTERATION AREA ( SQ.CM)
PAPERWIREMESH
WEIGHT
Kgs
FIF04
FIF08
FIF10
1 /2”
3/4”
1”
1-1/4”
1-1/2”
67
87
120
44
52
70
105
128
222
149
180
292
21
23
31
38
44
57
88
114
142
M8
M8
M10
920
2206
7237
315
774
2096
0.900
1.800
3.600
FILTER HOUSING
28
FIF
Pressure drop curve
0
50
100
150
200
p (bar)∆
0.5
1
1.5
2FIF 04,06 & FIF 08
40 80 120 160
L/MIN
0
50
100
150
200 FIF 10,12
75 150 225 300
L/MIN
p (bar)∆
0.5
1
1.5
2
FIF R 04 B 010 R4
Nominal Sizecomplete filter
R - RETURN
S - SUCTION
B - NO BY PASS
PORT FLTER MEDIA By-pass valve
04 – 1/2”
06 – 3/4”
08 – 1”
THREAD
B - BSP
N - NPT
S - SAE
10 – 1.1/4”
12 – 1.1/2”
010 – 10 PAPER
025 – 25 PAPER
A10 – 10 ABS
A25 – 25 ABS
149 – 149 wire mesh
R4 – 25 PSI
R – 15 PSI
S1 – 3 PSI
S2 – 5 PSI
29
Return line filters
FRC
Max working:700 kPa ( 7 bar )
Test:1 MPa ( 10 bar )
Bursting:2.1 MPa ( 21 bar )
Collapse, differential for the filter element : 300 kPa ( 3 bar )
BYPASS VALVE
170 kPa (1.7 bar)+/- 10%
WORKING TEMPERATURE
From -25° to +110° C
COMPATIBILITY
Full with fl uids: HH-HL-HM-HR-HV-HG
MATERIALS
Head :Die cast alluminum alloy
Spin-on-cartridge :Steel
Seals:Nitrile ( buna n)
Indicator housing:Brass
PRESSURE
A visual clogging indicator allows monitoring of the element
condition and provides maximum by indicating the exact
time for the element replacement.
VISUAL CLOGGING INDICATOR
element life
EASY REPLACEMENTThe top end cap inclu-des a handle allowing an easy removal of the element and a comple-te cleaning of the bowl.
Bypass valve :Polyamide 66
QUICK MAINTENANCEThe filter comes with a threaded cap,thus no tool is required whilereplacing the element.
F30 F80-F81 Fp1
30
Return line filters
FRC
kg
FRC11
FRC12
FRC21
FRC22
0,3+1,0
0,3+1,3
0,8+1,3
0,8+1,4
3/4”
3/4”
1 1/2”
D1
7
1 1/2”
7
9
D3
9
196
241
252
H1
297
25
25
36
36
H2
18
18
18
H3
70
18
70
100
E1
70
100
70
100
E2
100
50
50
72
E3
38
72
38
56
E4
38
56
38
56
E5
90
56
90
124
E6
124
95
95
130
130
D2
15
15
30
Tank cut out for FRC11 & 12 is 63 mm dia and dia 94 mm for FRC21 & 22
30
R
FILTER HOUSING
E4 E5D1
H3
H2
H1
R
D2
E6
E1
E2
D1
E3
D3
Part No.
31
Clogging Indicators
FRC
Series F30 (rear connection):
pressure gauge, scale 0 - 600 kPa (0 - 6 bar)
Series F80 (N.O. contacts) & series F81 (N.C. contacts):pressure switch, max voltage 220 Vca 50-60 Hz max current 0,5A resistive, 0,25A inductive switching power 100 VA, setting 150 kPa (1,5 bar) for F80 & F81protection IP65.
Series FP1 :SPDT, pressure switchmax voltage 250V - 50Hzmax current 6A resistive,1A inductive protection IP65setting 150 kPa (1,5 bar) for FP1
40
31
1/8”
56
30
1/8”
PG6 PG9
80
10
1/8”
2 Area (cm )Media F+ Media C+
A B C
ERC11
ERC12
ERC21
ERC22
96,5
96,5
129
129
3/4” BSP
3/4” BSP
1”1/4” BSP
1”1/4” BSP
146
191
181
226
2.140
3.630
4.450
5.890
3.305
4.745
5.560
7.360
1.20
1.40
1.50
Kg
FILTER ELEMENT
Part No.
1.00
C
B
A
32
Pressure drop curves
FRC
50 100 150 200 250 300
FRC
0
10
20
30
40
l/min
p (kPa)
350 400
1 1/2"3/4"
p (bar)
0,1
0,2
0,3
0,4
25 50 75 100 125 150
ERC 11
0
25
50
75
100
l/min
p (kPa)
FB
FD
CCCD
FC
p (bar)
0,25
0,5
0,75
1
25 50 75 100 125 150
ERC 12
0
25
50
75
100
l/min
p (kPa)
FD
CCCD
FC
FB
p (bar)
0,25
0,5
0,75
1
50 100 150 200 250 300
ERC 21
0
25
50
75
100
l/min
p (kPa)
FD
CC
CD
FCFB
p (bar)
0,25
0,5
0,75
1
50 100 150 200 250 300
ERC 22
0
25
50
75
100
l/min
p (kPa)
FDCC
CD
FCFB
p (bar)
0,25
0,5
0,75
1
25 50 75 100 125 150
FRC 11-12
0
100
200
300
400p (kPa)
l/min
p (bar)
1
2
3
4
100 200 300 400 500 600
FRC 21-22
0
100
200
300
400
l/min
p (kPa)p (bar)
1
2
3
4
FILTER HOUSING PRESSURE DROP(mainly depending on the port size)
CLEAN FILTER ELEMENT PRESSURE DROPWITH F+ AND C+ MEDIA
BYPASS VALVE PRESSURE DROP
The assembly Pressure drop( p) is obtained by adding the pressure drop values of the filter housing and the clean filterelement corresponding to the considered flow rate lower than 50 kPa ( 0.5 bar).
Disclaimer : All the curves obtained are with mineral oil of kinematic viscosity of 30 cSt and specific gravity of 0.9 kg/dm2. All curves are obtained at test done at FFP PRODUCTS INDIA (TESTING DIVISION).
33
Ordering Information
FRC
CC = cellulose 10
CD= cellulose 25
m
m
FB = fiber 7 m(c)
FC = fiber 12 m(c)
FD = fiber 21 m(c)
PORT TYPE
FAMILYSIZE & LENGTH
CR
B = BSP THREAD
PORT SIZE
FILTER MEDIA FILTER MEDIA
SEALS
BY PASS VALVE
B = 170 kPa ( 1.7 bar )
B
SEALS
F = FKM
N = NBR
CLOGGING INDICATOR
ACCESSORIES
X = NO ACCESSORIES
B
X
&!-),93):%
ELEMENT
R C
B
B
N
F
FC
FD
CC
CD
X
FB
B
B
N
F
FC
FD
CC
CD
X
FB
B
B
N
F
FC
FD
CC
CD
X
FB
B
B
N
F
FC
FD
CC
CD
X
FB
F = FKM FLUROELASTOMER
N = NBR NITRILE
B= FILTER HOUSING
F= FILTER COMPLETE
TYPE
F
B
F
B
F
B
F
B
06 = 3/4”
12 = 1.1/2”
FAMILY SIZE & LENGTH
E
21
05 = nr. 2 x 1/8" ports, plugged
F80= press. switch, N.O.
F81= press. switch, N.C.
Fp1= SPDT, Pressure switch
F30= pressure gauge, rear connection
11 12 22
06 06
12 12
P1 P1 P1 P1
81 81 81 81
80 80 80 80
30 30 30 30
05 05 05 05
34
Return line filters
TTF
Max working:300 kPa ( 3 bar )
Test:500 kPa ( 5 bar )
Bursting:1 MPa ( 10 bar )
Collapse, differential for the filter element : 300 kPa ( 3 bar )
BYPASS VALVE
170 kPa (1.7 bar)+/- 10%
WORKING TEMPERATURE
From -25° to +110° C
COMPATIBILITY
Full with fl uids: HH-HL-HM-HR-HV-HG
MATERIALS
Head & cover:Die cast alluminum alloy
Bowl:Polyamide 66
Seals:Nitrile ( buna n)
Indicator housing:Brass
PRESSURE
A visual clogging indicator allows monitoring of the element condition and provides maximum
by indicating the exact time for the element replacement.
VISUAL CLOGGING INDICATOR
element life
FILLING PLUGThe Filling plug option gives the possibility of easily and efficiently Filtering the oil from the tank.
EASY REPLACEMENTThe top end cap inclu-des a handle allowing an easy removal of the element and a comple-te cleaning of the bowl.
NO LEAKSThe end cap with captive O-ring ensures a perfect seal between filter element and the bowl.
Bolts.Filling plug.
Cover
O-ring
By-pass valve
Filter element
O-ring
Filter head
O-ring
Filter bowl
F30 F80-F81 Fp1F32
35
Return line filters
TTF
FILTER HOUSING
weight in kg
TTF11
TTF21
TTF31
TTF32
TTF33
TTF41
TTF51
TTF52
TTF53
3/8”
½”
½” - 3/4”
3/4” - 1”
3/4” - 1”
1” - 1 1/2”
1 1/4” - 1 1/2”
1 1/2” - 2” - 2 1/2”
1 1/2” - 2” - 2 1/2”
50
67
89
89
89
126
174
174
174
50
68
90
90
90
131
180
180
180
12
24
28
28
40
40
50
63.5
63.5
80
90
115
115
115
175
220
220
220
6.5
6.5
9
9
9
10.5
10.5
10.5
10.5
40
50
67
67
67
95
115
115
115
59
80
102
150
234
248
178
240
285
16
20
25
25
30
50
50
50
50
12
22
28
28
28
35
55
55
55
33
33
47
47
47
56
69
69
69
9
9
10
10
10
13
13
13
13
1/8”
3/8”
3/8”
3/8”
3/8”
½”
½”
½”
½”
90
120
150
190
270
289
250
315
355
0.30
0.45
0.80
0.95
1.10
2.10
3.10
3.60
4.10
D1minD2
maxD2 D3 D4 D5 E H1 H 2 H3 H4 H6 P RPart No
E
D1
H3
H4
D5
H6
D3
H2
H1
D4D2
P
D4
D2
P
D4
D2
P
90
4575
60
30
TTF11,21,31,32-33
TTF41
TTF51,52-53
36
Clogging Indicators
TTF
Series F30 (rear connection) & series F32 (bottom connection): pressure gauge, scale 0 - 600 kPa (0 - 6 bar)
Series F80 (N.O. contacts) & series F81 (N.C. contacts):pressure switch, max voltage 220 Vca 50-60 Hz max current 0,5A resistive, 0,25A inductive switching power 100 VA, setting 150 kPa (1,5 bar)protection IP65.
Series FP1:SPDT, pressure switchmax voltage 250V - 50Hzmax current 6A resistive,1A inductive protection IP65setting 150 kPa (1,5 bar)
Part No
40
31
1/8”
40 30
1/8”
56
30
1/8”
PG6 PG9
80
10
1/8”
FILTER ELEMENTArea (cm2)
Media F+ Media C+A B C
ETF11
ETF21
ETF31
ETF32
ETF33
ETF41
ETF51
ETF52
ETF53
38
52
70
70
70
99
130
130
130
13
24
28
28
40
40
51
63
63
50
70
85
130
210
211
140
200
251
270
310
620
1.000
1.660
3.800
4.140
6.190
7.930
345
380
990
1.600
2.670
4.280
4.360
6.520
8.350
0.05
0.10
0.20
0.25
0.40
0.75
1.00
1.35
1.50
Kg
C
A
B
37
Pressure drop curves
TTFThe assembly Pressure drop( ) is obtained by adding the pressure drop values of the filter housing and the clean filterelement corresponding to the considered flow rate lower than 50 kPa ( 0.5 bar).
∆p
CLEAN FILTER ELEMENT PRESSURE DROPWITH F+,C+ & ME MEDIA
TTF11
0
12,5
25
37,5
50p (kPa)
CDCC
FD
ME
FC
FA
FB
l/min
p (bar)
0,125
0,2
0,375
0,5TTF21
0
25
50
75
100
l/min
p (kPa)
CD
CCFD
FC
ME
FA FB
p (bar)
0,2
0,5
0,75
1TTF31
0
25
50
75
100
l/min
p (kPa)
CD
CC
FDFC
ME
FBFA
p (bar)
0,25
0,5
0,75
1
TTF32
0
25
50
75
100p (kPa)
CD
CCFD
FC
ME
FBFA
l/min
p (bar)
0,25
0,5
0,75
1TTF33
0
25
50
75
100p (kPa)
CD
FD
FC
CC
ME
FBFA
l/min
p (bar)
0,25
0,5
0,75
1TTF41
0
25
50
75
100
l/min
p (kPa)
FD
CD
CC
ME
FA FB
FC
p (bar)
0,25
0,5
0,75
1
TTF51
0
25
50
75
100
l/min
p (kPa)
FC
FD
CD
CC
ME
FA FB
p (bar)
0,25
0,5
0,75
1TTF 52
0
25
50
75
100
l/min
p (kPa)
FC
FD
CD
CC
ME
FBFA
p (bar)
0,25
0,5
0,75
1TTF53
0
25
50
75
100
l/min
p (kPa)
FC
FD
CD
CC
FBFA
ME
p (bar)
0,25
0,5
0,75
1
Disclaimer : All the curves obtained are with mineral oil of kinematic viscosity of 30 cSt and specific gravity of 0.9 kg/dm2. All curves are obtained at test done at FFP PRODUCTS INDIA (TESTING DIVISION).
BYPASS VALVE PRESSURE DROP
TTF21-31-32-33
0
100
200
300
400
l/min
p (kPa)p (bar)
1
2
3
4TTF41-51-52-53
0
100
200
300
400
l/min
p (kPa)p (bar)
1
2
3
4
7.5 15 22.5 30 37.5 45 15 30 45 60 75 90 15 30 45 60 75 90
25 50 75 100 125 150 25 50 75 100 125 150 50 100 150 200 250 300
50 100 150 200 250 300 100 200 300 400 500 600 100 200 300 400 500 600
25 50 75 100 125 150 100 200 300 400 500 600
38
Ordering information
TTF
F = FKM
N = NBR
BB
N
F
N
F
FA
FB
FC
FD
CC
ME
FA
FB
FC
FD
CC
ME
01
30
32
80
01
30
32
80
W
P
W
P
FT
32312111
B
N
S
-
B
N
S
-
B
N
S
-
B
N
S
-
B
N
S
-
B
N
S
-
03
–
–
-
-
-
–
04
–
-
-
-
–
04
06
-
-
-
–
–
06
08
-
-
–
-
-
08
–
-
–
-
-
08
10
-
BBBX
N
F
N
F
N
F
N
F
FA
FB
FC
FD
CC
ME
FA
FB
FC
FD
CC
ME
FA
FB
FC
FD
CC
ME
FA
FB
FC
FD
CC
ME
01
30
32
80
01
30
32
80
01
30
32
80
01
30
32
80
W
P
W
P
W
P
W
P
BYPASS
B = 170 kPa (1.7 bar)
FILTER MEDIA
FILTER MEDIA
SEALS
SEALS
CC = cellulose 10
ME = wire mesh 60
CC = cellulose 10
ME = wire mesh 60
ACCESSORIES
W = without
CLOGGING INDICATOR
01 = 1/8" port, plugged
30 = Pressure gauge, rear connection
32 = Pressure gauge, bottom connection
80 = press. switch, N.O.Contacts
P = with filling plug
PORT SIZE
PORT TYPE
FAMILY, NOMINAL SIZE & LENGTH
04 = 1/2"
06 = 3/4"
08 = 1"
12 = 1 1/2"
03 = 3/8"
E
T F
ELEMENT
FAMILYSIZE & LENGTH
B = BSP thread
S = SAE thread
F = SAE flange 3000 psi
10 = 1 1/4"
F = FKM Fluoroelastomer
N = NBR Nitrile
B = FILTER HOUSING
F = FILTER COMPLETE
TYPE
T
B
T
B
T
B
T
B
T
B
T
B
m >2
m
>1.000FA = fiber 5 m(c)
>1.000FB = fiber 7 m(c)
>1.000FC = fiber 12 m(c)
>1.000FD = fiber 21 m(c)
m
m
FA = fiber 5 m(c)
FB = fiber 7 m(c)
FC = fiber 12 m(c)
FD = fiber 21 m(c)
33 41
N = NPT thread
16 = 2”
20 = 2 1/2"
CD = cellulose 25 m >2
81 = press. switch, N.C.Contacts
P1 = SPDT, press switch
B
N
F
FA
FB
FC
FD
CC
ME
01
30
32
80
W
P
5251
B
N
S
F
B
N
S
F
B
N
S
F
–
–
–
-
10
12
–
–
–
-
10
12
–
-
-
–
–
-
BB
N
F
N
F
FA
FB
FC
FD
CC
ME
FA
FB
FC
FD
CC
ME
01
30
32
80
01
30
32
80
W
P
W
P
T
B
T
B
T
B
53
- - - - - - 16 16 16- - - - - - 20 20 20
CD CDCDCDCDCD CDCDCD
81
P1
81
P1
81
P1
81
P1
81
P1
81
P1
81
P1
81
P1
81
P1
l/min0
10
20
30
40TTF
3/8" 1/2" 3/4" 1" 1 1/4" 1 1/2" 2"
p (kPa)p (bar)
0,1
0,2
0,3
0,4
FILTER HOUSING PRESSURE DROPDEPENDENT ON THE PORT SIZE
50 100 150 200 250 300 350 400 450 500 550 600 650 700 750
39
Return line filters
TTU
Max working:300 kPa ( 3 bar )
Test:500 kPa ( 5 bar )
Bursting:1 MPa ( 10 bar )
Collapse, differential for the filter element : 300 kPa ( 3 bar )
BYPASS VALVE
170 kPa (1.7 bar)+/- 10%
WORKING TEMPERATURE
From -25° to +110° C
COMPATIBILITY
Full with fl uids: HH-HL-HM-HR-HV-HG
MATERIALS
Head & cover:Die cast alluminum alloy
Bowl:Polyamide 66
Seals:Nitrile ( buna n)
Indicator housing:Brass
PRESSURE
A visual clogging indicator allows monitoring of the element condition and provides maximum
by indicating the exact time for the element replacement.
VISUAL CLOGGING INDICATOR
element life
FILLING PLUGThe Filling plug option gives the possibility of easily and efficiently Filtering the oil from the tank.
EASY REPLACEMENTThe top end cap inclu-des a handle allowing an easy removal of the element and a comple-te cleaning of the bowl.
NO LEAKSThe end cap with captive O-ring ensures a perfect seal between filter element and the bowl.
Bolts.Filling plug.
Cover
O-ring
By-pass valve
Filter element
O-ring
Filter head
O-ring
Filter bowl
F30 F80-F81 Fp1F32
40
Return line filters
TTU
kg
TTU31
TTU32
TTU33
3/4” - 1” - 1” 1/4
3/4” - 1” - 1” 1/4
3/4” - 1” - 1” 1/4
106
152
235
165
205
D1
285
H R
1.10
1.25
FILTER HOUSING
0.95
D2
27
27
40
R
31
,7
H
84
1" BSP
Ø9
Ø9
110,5
69
D2
PCD 116 X 2 HOLES
PCD
126X
4HOLES
Ø126 Ø88
Ø8
45°
45°
TANK MOUNTING
41
Clogging Indicators
TTU
Series F30 (rear connection) & series F32 (bottom connection): pressure gauge, scale 0 - 600 kPa (0 - 6 bar)
Series F80 (N.O. contacts) & series F81 (N.C. contacts):pressure switch, max voltage 220 Vca 50-60 Hz max current 0,5A resistive, 0,25A inductive switching power 100 VA, setting 150 kPa (1,5 bar)protection IP65.
Series FP1:SPDT, pressure switchmax voltage 250V - 50Hzmax current 6A resistive,1A inductive protection IP65setting 150 kPa (1,5 bar)
40
31
1/8”
40 30
1/8”
56
30
1/8”
PG6 PG9
80
10
1/8”
C
A
B
85
130
210
28
28
40
70
70
70
990
1.600
2.670
620
1.000
1.660
0,20
0,25
0,40
2Area (cm )Media F+
AMedia C+
B C kg
TTUE31
TTUE32
TTUE33
FILTER ELEMENT
42
Return line filters
TTU TTU 41 - 42
Tank mounting pattern
H1
kg
TTU41
TTU42
1” 1/2
1” 1/2
248
265
289
306
D1 D3D2 H1 R
40
40
1 1/2”
1 1/2”
2,40
2,60
FILTER HOUSING
43
Pressure drop curves
TTU
The “Assembly Pressure Drop (∆p)” is obtained by adding the pressure drop values of the Filter Housing and of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than 50 kPa (0,5 bar).
PRESSURE DROP CURVES (∆p)
Δp (bar)
0,1
0,2
0,3
0,4
l/min0
10
20
30
40
50 100 150 200 250 300 350 400 450 500
TTU
3/4"
Δp (k
1"
Pa)
FILTER HOUSING PRESSURE DROP(mainly depending on the port size)
1” 1/4
CLEAN FILTER ELEMENT PRESSURE DROP WITH F+, C+ AND ME MEDIA
Δp (bar)
0,25
0,5
0,75
1
15
TTU 31
0 30 45 60 75 90
25
50
75
100Δp (k
l/min
Pa)
CD
CC
FDFC
FBFA
ME
Δp (bar)
0,25
0,5
0,75
1
25
TTU 32
0 50 75 100 125 150
25
50
75
100Δp (k
l/min
Pa)
CCFD
FCFBFA
MECD
Δp (bar)
0,25
0,5
0,75
1
25
TTU 33
0 50 75 100 125 150
25
50
75
100Δp (k
l/min
Pa)
FD
FC
CC
FBFA
MECD
25
TTU 31-32-33
0 50 75 100 125 150
100
200
300
400
l/mi
Δp (k
n
Pa)Δp (bar)
1
2
3
4
BYPASS VALVE PRESSURE DROP
1” 1/2
1000 200 300 400 500 600
100
200
300
400Δp (k
l/min
Pa)Δp (bar)
1
2
3
4TTU 41-42
44
Ordering information
CC = cellulose 10 CC = cellulose 10
CD = cellulose 25 CD = cellulose 25
PORT TYPE
FAMILY,
NOMINAL SIZE & LENGTH
UT
B = BSP
A = BSP thread (double port A08 only)
thread
N = NPT thread
S = SAE thread
PORT SIZE
06 = 3/4"
08 = 1"
10 = 1"1/4
P1 = SPDT, pressure switch
30 = pressure gauge, rear connection
05 = nr. 2 x 1/8"ports, plugged
CLOGGING INDICATOR
FILTER MEDIA FILTER MEDIA
FAMILYSIZE & LENGTH
ELEMENT E
T U
ME = wire mesh 60 ME = wire mesh 60
33
05
30
P1
FA
FB
FC
FD
CC
CD
ME
06
08
10
B
N
S
32
05
30
P1
FA
FB
FC
FD
CC
CD
ME
06
08
10
B
N
S
05
30
P1
FA
FB
FC
FD
CC
CD
ME
06
08
10
B
A A A
N
S
31
ACCESSORIES
W = without
P = with filling plug
W
P
W
P
W
P
B = FILTER HOUSING
F = FILTER COMPLETE
TYPE
T
B
T
B
T
B
m >2
m
>1.000FA = fiber 5 m(c)
>1.000FB = fiber 7 m(c)
>1.000FC = fiber 12 m(c)
>1.000FD = fiber 21 m(c)
m >2 m
m
FA = fiber 5 m
FB = fiber 7 m
FC = fiber 12 m
FD = fiber 21 m
m
SEALS
BYPASS VALV E
B = 170 kPa (1,7 bar)
B
SEALS
N = NBRN = NBR Nitrile N
B
N
B
N
FFF
B
F = FKM Fluoroelastomer F = FKM
TTU
45
Ordering information
TTU
CC = cellulose 10 CC = cellulose 10
CD = cellulose 25 CD = cellulose 25
P1 = SPDT, pressure switch
30 = pressure gauge, rear connection
05 = nr. 2 x 1/8"ports, plugged
CLOGGING INDICATOR
FILTER MEDIA FILTER MEDIA
ME = wire mesh 60 ME = wire mesh 60
ACCESSORIES
W = without
P = with filling plug
ACCESSORIES
X = no other accessory available
05
30
P1
FA
FB
FC
FD
CC
CD
ME
W
P
X
05
30
P1
FA
FB
FC
FD
CC
CD
ME
W
P
X
m >2
m
>1.000FA = fiber 5 m(c)
>1.000FB = fiber 7 m(c)
>1.000FC = fiber 12 m(c)
>1.000FD = fiber 21 m(c)
m >2
FA = fiber 5 m(c)
FB = fiber 7 m(c)
FC = fiber 12 m(c)
FD = fiber 21 m(c)
X
PORT TYPE
FAMILY,
NOMINAL SIZE & LENGTH
UT
1 2 PORT SIZE
12 = 1 1/2"
FAMILYSIZE & LENGTH
ELEMENT E
T U
P = SAE flange 3000 psi, double port
B = FILTER HOUSING
F = FILTER COMPLETE
TYPE
12
P
41
T
B
42
12
P
T
B
SEALS
BYPASS VALV E
B = 170 kPa (1,7 bar)
B
P
SEALS
N = NBRN = NBR Nitrile N
B
N
FF
B
F = FKM Fluoroelastomer F = FKM
211
250
40
40
99
99
4.280
5.100
3.800
4.550
0,75
0,90
2Area (cm )Media F+
AMedia C+
B C kg
FILTER ELEMENT
TTUE41
TTUE42
C
B
A
46
By Pass valves
BPVTECHNICAL DATA:
Body : Polyamide 66Spring : Zinc plated Spring steelWorking temperature : -25 to +100CSeals : Nitrile ( buna N )Preset Pressure : 1.5 bar
OPTIONAL :Valve Opening pressure on request.
Model No : BPV1 Model No : BPV2
Model No : BPV3 Model No : BPV4
47
HIGH PRESSURE FILTERS
48
HIGH PRESSURE FILTERS
FHP
15
10
5
0
0 30 60 90 120 150
1,503/ 4”
1,00
0,50
0,00
0 30 60 90 120 150
3,00
1,50
0,000 20 40 60 80 100
Δp
ba
r
Flow rate I/min
Flow rate I/min
450 700 1000
Filter Element Area
Filter element in stainless steel mesh
1
2
3
4
FHP50
Values expressed in cm2
Length
TypeFilter body
> Head: Cast iron (chemical heat treated)
> Housing: Steel (chemical heat treated)
> Bypass valve : Steel
Pressure
> Working pressure : 420 bar (42 MPa)
> Test pressure : 420 bar (42 MPa)
> Burst pressure : 840 bar (84 MPa)
Temperature
> From -25°C to +110°C
Bypass valve
> Opening pressure 6 bar ±10%
> Other opening pressures on request
Elements type Δp
> Microfibre filter elements series N: 20 bar
> Microfibre filter elements series H: 210 bar
> Stainless steel mesh elements series N: 20 bar
> Oil flow from exterior to interior.
Seals
> Standard Nitrile (NBR) series A
> Optional FPM series V
Compatibility
> Bodies compatible with:Mineral oils to ISO 2943 - aqueous emulsionssynthetic fluids, water/glycol.
> Filter elements compatible with: Mineral oils to ISO 2943 - aqueous emulsionssynthetic fluids, water/glycol.
> Nitrile (NBR) seals series A, compatible with:Mineral oils to ISO 2943 - aqueous emulsionssynthetic fluids, water/glycol.
> V series FPM seals, compatible with:Synthetic fluids type HS-HFDR-HFDS-HFDUTo ISO 2943
Pressure drops Δp Housing
The curves are plotted using mineral oil 3with density of 0.86 kg/dm to ISO 3968.
Δp varies proportional with density.
Filter Housing
Δp
ba
rΔ
p b
ar
Technical data
Bypass valve pressure drops
1300
49
HIGH PRESSURE FILTERS
Standard Indicator Option P03 with indicatorat 90
195
158
Recommended maximum flow rate
- Pressure drop of complete filter equal to Δp 1.5 bar.
2- Oil kinematic viscosity 30 mm /s (cSt).
3- Density 0.86 kg/dm .
- Connections of filter under test G 3/4”.
H
195
237
285
Length
1
2
3
4
Filter Flow rate Flow rate Filter element l/min l/min Length
type Series N Series H
A03 44 30
A06 44 40
A10 80 58 1
A16 82 60
A25 110 75
M25 140 -
A03 53 45
A06 58 50
A10 87 78 2
A16 100 90
A25 125 119
M25 140 -
A03 68 59
A06 71 62
A10 100 92 3
A16 110 100
A25 135 130
M25 140 -
A03 85 75
A06 92 82
A10 118 106 4
A16 120 112
A25 135 135
M25 145 -
50
FHP
HIGH PRESSURE FILTERS
No
1
2
3
4
5
6
7
8
9
Description
Filter Head & Housing
Filter Element
Seal kits
O-Ring for filter element
O-Ring for housing
Anti-extrusion ring
Gasket
O-Ring
Protection seal
Indicator plug
FHP050 series FILTER050 1 - 2 - 3 - 4
NBR FPM
O-RING
Ø 23.67 x 2.62
O-RING
Ø 56.82 x 2.62
O-RING
Ø 56.03 x 2.18
(HNBR) (FPM)
O-RINGØ 12.42 x 1.78
TEFLON
FT2H FT2V
1
1
3
2
4
9 6
5
7
8
C.I (heat treated)Steel(heat treated)
51
FHP
HIGH PRESSURE FILTERS
1 - Filter lengths
1
2
3
4
2 - Bypass valve
W Without bypass
B With bypass
C Without bypass + check valve
E With bypass + check valve
3 - Seals
A NBR
V FPM
4 - Threaded connections
A M18X1.5 ISO 6149
B M22X1.5 ISO 6149
C G 1/2”
D G 3/4”
E 1/2” NPT
F 3/4” NPT
G SAE 8 (3/4”- 16 UNF)
H SAE 12 (1 1/16” - 12 UN)
FHP050
1 2 3 4 5 6
1 5 3 6
HP 050
Filter assembly
Filter element
Example: HP050 2 A10 A N P01
Example: HP050 2 B A D A25 N P01
ßx(c) ≥ 1000
Ordering information
5 - Filter elements
A03 Inorganic microfibre 3 µ
A06 Inorganic microfibre 6 µ
A10 Inorganic microfibre 10 µ
A16 Inorganic microfibre 16 µ
A25 Inorganic microfibre 25 µ
M25 Stainless steel mesh 25 µ(N style only)
6 - Filter elements differential pressure
N 20 bar
S 210 bar
7 - Options
Filter
P01 Standard threaded connection for indicator
P02 Without threaded connection for indicator
P03 Threaded connection for indicator at 90°
P04 Customer request
52
FHP
HIGH PRESSURE FILTERS
FMM
FMM is the medium pressure filter up to22.000.000 Pa (220 bar- 3200 Psi); the range iscomposed of two different sizes with nominalflow rates up to 170 l/min. with threaded or flan-ged connections.
MATERIALS (housing)
Head
Bowl
Seals
By-pass valve
Reverse flow valve
Indicator
Aluminium
Steel
N: Nitrilic (Buna-N)
V: Fluoroelastomer (Viton)
Brass
Steel
Brass
WORKING CONDITIONS
Filter pressure
Operating pressure
Collapse pressure
(Filter Element)
By-pass valve
setting pressure
Compatibily with
hydraulic fluids
ISO 2943
Max working pressure:
22.000.000 Pa (220 bar)
Testing pressure:
44.000.000 Pa (440 bar)
Burst pressure:
66.000.000 Pa (660 bar)
-20 a +95o c
X series : 2.000.000 Pa (20 bar)
Y series : 21.000.000 (210 bar)
600.000 Pa ±10% (6 bar)
(from opening)
Compatible with mineral oils such as
HH,HM,HR,HV,HG according
to ISO 6743/4)
53
HIGH PRESSURE FILTERS
FMM series 28
Flows have been calculated just in order to obtaina pressure drop ∆p ≤ 120.000 Pa (1.2 bar) withmineral oil kinematic viscosity 30 cSt and 860kg/m3 density.
1
2
3
4
5
1/2” BSP
3/4” BSP
1/2” NPT
3/4” NPT
SAE8 - 3/4”-16UNF
SAE12 - 1 1/16”- 12UN
M 8
M 8
5/16” UNC
5/16” UNC
5/16” UNC
5/16” UNC
Tipo / Type A E (depth 15mm)
RECOMMENDED FLOWS(Glass fibre elements)
THREADED CONNECTIONS
AT
1
2
3
189
219
319
FMM281
FMM282
FMM283
Tipo / Type H (mm) Length
281
281
281
281
282
282
282
282
283
283
283
283
F03
F06
F10
F25
F03
F06
F10
F25
F03
F06
F10
F25
FMM Replaceelement
17
20
35
50
26
40
55
80
38
50
70
95
Flow (L/min)X series
15
18
33
47
22
29
50
70
32
40
60
85
Flow (L/min)Y series
2,65
2,65
2,65
2,65
3,2
3,2
3,2
3,2
4,7
4,7
4,7
4,7
Weight (Kg)
LENGTHS
A
43
H1
00
ø70
E
46
87
68
A/F 30
13.510
ø8.5
30
40
43
.54
3.5
1/2
” BS
P
FMM
54
HIGH PRESSURE FILTERS
FMM series 42
I
M
G
Flows have been calculated just in order to obtaina pressure drop ∆p ≤ 120.000 Pa (1.2 bar) withmineral oil kinematic viscosity 30 cSt and 860kg/m3 density.
1
2
3
4
5
3/4” BSP
1” BSP
3/4” NPT
1” NPT
SAE12 - 1 1/16”-12UN
SAE16 - 1 5/16”-12UN
M 10
M 10
3/8” UNC
3/8” UNC
3/8” UNC
3/8” UNC
Type A E (depth 15mm)
RECOMMENDED FLOWSGlass fibre elements
THREADED CONNECTIONS
6
7
8
9
3/4”SAE -3000 PSI/M
1”SAE -3000 PSI/M
3/4”SAE -3000 PSI/UNC
1”SAE -3000 PSI/UNC
M 10
M 10
3/8” UNC
3/8” UNC
M 10
M 10
3/8” UNC
3/8” UNC
22.5
26.2
22.5
26.2
47.6
52.4
47.6
52.4
Type Connection I M G E(depth 15mm)
FLANGED CONNECTIONS
1
2
277
390
FHM421
FHM422
Type H (mm) Length
421
421
421
421
422
422
422
422
F03
F06
F10
F25
F03
F06
F10
F25
FMM Replaceelement
55
65
80
104
100
113
135
170
Flow (L/min)X series
38
55
60
75
80
90
115
145
Flow (L/min)Y series
3,9
3,9
3,9
3,9
5,6
5,6
5,6
5,6
Weight (Kg)
LENGTH
A/F30
A
113
94
ø78
12
5H
47
E
57
10
ø8.5
40
50.5
51.5
1/2
”BS
P
33
FMM
55
HIGH PRESSURE FILTERS
Pressure Drops(according to ISO 3968)
0
10
20
30
40
50
60
0 20 40 60 80 100
flow(L/min)
de
lta
P(K
Pa
)
0
300
600
900
1200
0 10 20 30 40 50
flow(L/min)
de
lta
P(K
Pa
)
0
140
120
100
80
60
40
20
160
180
200
0 10 20 30 40 50 60
flow(L/min)
de
lta
P( K
Pa
)
0F3 6
F0 F01
5F2
0
20
40
60
80
100
120
140
160
180
200
0 20 3010 40 50 7060 80 90 100
flow(L/min)
de
lta
P( K
Pa
)
F03
F06 1F0
25F
0
140
120
100
80
60
40
20
160
180
200
0 10 20 30 40 50 60
flow(L/min)
de
l ta
P( K
Pa
)
F03 06F
01F
F 52
0
20
40
60
80
100
120
140
160
180
200
0 20 3010 40 50 7060 80 90 100
flow(L/min)
de
lta
P(K
Pa
)
F03 F60 F
01
F25
∆P HOUSINGS BY-PASS
∆P X ELEMENTS∆P Y ELEMENTFMM 281series
∆P X ELEMENTS ∆P Y ELEMENTSFMM 282 series
FMM series 28
FMM
56
HIGH PRESSURE FILTERS
Pressure Drops(according to ISO 3968)
0
140
120
100
80
60
40
20
160
180
200
0 20 40 60 80 100 120
flow(L/min)
delt
aP
(KP
a)
F03
F06 10F
25F
0
140
120
100
80
60
40
20
160
180
200
0 20 40 60 80 100 120
flow (L/min)
delt
aP
(KP
a)
F30 F06 0
F1
F25
0
10
20
30
40
50
60
70
80
0 20 40 60 80 100 120 140 160 180 200flow(L/min)
delt
aP
(KP
a)
Con valvolaReverse flow
0
400
200
800
600
1200
1000
1600
1400
0 20 40 60 80 100flow(L/min)
delt
aP
(KP
a)
0
100
200
300
400
500
600
0 20 40 60 80 100flow(L/min)
delt
aP
(KP
a)
0
140
120
100
80
60
40
20
160
180
200
0 20 40 60 80 100 120 140
f/low(L/min)
delt
aP
(KP
a)
03F6
F0 F01
F 52
0
140
120
100
80
60
40
20
160
180
200
0 20 40 60 80 100 120 140
f/low (L/min)
delt
aP
(KP
a)
F30
F06F
0125
F
0
20
40
60
80
100
120
140
160
180
200
0 20 40 60 80 100 120 140 160 180
flow(L/min)
delt
aP
(KP
a)
3F0 06
F
0F1
25F
0
20
40
60
80
100
120
140
160
180
200
0 20 40 60 80 100 120 140 160 180
flow(L/min)
delt
aP
(KP
a)
F30 06
F 0F1
5F2
∆P X ELEMENTS ∆P Y ELEMENTSFMM 421 series
∆P X ELEMENTS ∆P Y ELEMENTSFMM283 series
∆P HOUSINGS BY-PASS REV. FLOW VALVE
∆P X ELEMENTS ∆P Y ELEMENTS
FMM422 series
FMM series 42
FMM
57
HIGH PRESSURE FILTERS
Ordering Info
F M M 281 T25 Y N S 3
EHP 421 F03 Y N
Nominal Size
281
282
283
421
422
-
1
2
3
4
5
6
7
8
9
Filtration Element
A FMM28
1/2” BSP
3/4” BSP
1/2” NPT
3/4” NPT
SAE8 3/4” - 16UNF
SAE12 1 1/16” - 12UN
3/4” BSP
1” BSP
3/4” NPT
1” NPT
SAE12 1 1/16” - 12UN
SAE16 1 5/16” - 12UN
3/4” SAE-3000PSI/M
1” SAE-3000PSI/M
3/4” SAE-3000PSI/UNC
1” SAE-3000PSI/UNC
FMM42
-
C10
C25
F03
F06
F10
F25
T10
T25
10 µm
25 µm
3 µm
6 µm
10 µm
25 µm
10 µm
25 µm
Without filtration elements
Resin treated cellulose ßx>2
Resin treated cellulose ßx>2
Inorganic fibre ßx > 200
Inorganic fibre ßx > 200
Inorganic fibre ßx > 200
Inorganic fibre ßx > 200
Steel Aisi 304 Wire mesh
Steel Aisi 304 Wire mesh
Seals
N
V
S
R
P
Q
Buna-N
Viton
∆P. Cartridge
X
Y
2.000.000
(20 Bar)
21.000.000
(210 Bar)
for filters with By-pass
for filters without By-pass
By-pass valve
Without By-pass
By-pass ∆p 6 bar
With reverse flow valve
With reverse flow valve + By-Pass
(Replacement element)
CONNECTIONS
FMM
58
HIGH PRESSURE FILTERS
FAP
FPA is the medium pressure filter up to11.100.000 Pa (110 bar- 1600 Psi); the range iscomposed of two different sizes with nominalflow rates up to 60 l/min. with threaded or flan-ged connections.
MATERIALS (housing)
Head
Bowl
Seals
By-pass valve
Indicator
Aluminium Anodized
N: Nitrilic (Buna-N)
V: Fluoroelastomer (Viton)
Brass
Brass
WORKING CONDITIONS
Filter pressure
Operating pressure
Collapse pressure
(Filter Element)
By-pass valve
setting pressure
Compatibily with
hydraulic fluids
ISO 2943
Max working pressure:
11.100.000 Pa (110 bar)
Testing pressure:
16.000.000 Pa (160 bar)
Burst pressure:
30.000.000 Pa (300 bar)
-20 a + 1 1 0o c
X series : 8.00.000 Pa (80 bar)
Y series : 8.000.000 (80 bar)
600.000 Pa ±10% (6 bar)
(from opening)
Compatible with mineral oils such as
HH,HM,HR,HV,HG according
to ISO 6743/4)
Aluminium Anodized
59
HIGH PRESSURE FILTERS
FAP
FILTER HOUSING
kg
FPA11
FPA12
1/2”
D1
157
1/2”
H1
78
244
H2
79
78
H3
28
166
H4
50
28
H5
17
50
H6
64
17
E1
64
E2 E3
6,5
D2
0,65
6,5 0,85
76
76
75
75
60
R
60
E2
E1
D 1
D2
H6
D 1
H2
H4
H5
H1
H3
R
22
E3
6
60
HIGH PRESSURE FILTERS
FAP
F = FKM Fluoroelastomer
N = NBR Nitrile
PORT TYPE
B = BSP
thread
N = NPT thread
S = SAE thread
B B
N N
S S
FAMILYNOMINAL
SIZE & LENGHT
AP FAMILYSIZE & LENGHT
ELEMENT E
P A
11 12
PORT SIZE
04 = 1/2" 04 04
0 4
BYPASS VALV E
W = without W W
C CC = 600 kPa (6 bar)
F = FKM
N = NBRN N
F F
SEALSSEALS
FA
FB
FC
FD
CC = cellulose 10 CC
FA
FB
FC
FD
CC CC = cellulose 10
FILTER MEDIAFILTER MEDIA
6E = electrical differential 500 kPa (5 bar)
5E = visual differential 500 kPa (5 bar)
03 = port, plugged
CLOGGING INDICATOR
03
5E
6E
03
5E
6E
B = FILTER HOUSING
F = FILTER COMPLETE
TYPE
F
B
F
B
m >2
>1.000FA = fiber 5 m(c)
>1.000FB = fiber 7 m(c)
>1.000FC = fiber 12 m(c)
>1.000FD = fiber 21 m(c)
m
FA = fiber 5 m(c)
FB = fiber 7 m(c)
FC = fiber 12 m(c)
FD = fiber 21 m(c)
FILTER ELEMENT2Area (cm )
Media F+A
Media C+B C
EPA11
EPA12
C
øA
øB
kg
22
22
42
42
91
179
295
600
295
600
0,15
0,25
Ordering Info
61
HIGH PRESSURE FILTERS
FAP
Δp (kPa)
10
FPA
0 20 40 50 60
25
50
75
100
l/min
1/2"
30
Δp (bar)
0,25
0,5
0,75
1
CLEAN FILTER ELEMENT PRESSURE DROP
FILTER HOUSING PRESSURE DROP
The “Assembly Pressure Drop (∆p)” is obtained by adding the pressure drop values of the Filter Housing and
of the Clean Filter Element corresponding to the considered Flow Rate and it must be lower than 80 kPa (0,8 bar).
PRESSURE DROP CURVES (∆p)
3
5
FPA
0 10 20 25 30
300
600
900
Δp (k1200
Pa)
l/min15
Δp (bar)
3
6
9
12
10
EPA 11
0 20 40 50 60
25
50
75
Δp (k100
Pa)
l/min
FAFB
FC FD
CC
30
Δp (bar)
0,25
0,5
0,75
1
15
EPA 12
0 30 60 75 90
25
50
75
Δp (k100
Pa)
l/min
FA FB FCFD
CC
45
Δp (bar)
0,25
0,5
0,75
1
BYPASS VALVE PRESSURE DROP
62
HIGH PRESSURE FILTERS
FHM
FHM is the medium pressure filter up to22.000.000 Pa (220 bar- 3200 Psi); the range iscomposed of two different sizes with nominalflow rates up to 170 l/min. with threaded or flan-ged connections.
MATERIALS (housing)
Head
Bowl
Seals
By-pass valve
Reverse flow valve
Indicator
Cast iron (chemical heat treatment)
Steel
N: Nitrilic (Buna-N)
V: Fluoroelastomer (Viton)
Brass
Steel
Brass
WORKING CONDITIONS
Filter pressure
Operating pressure
By-pass valve
setting pressure
Compatibily with
hydraulic fluids
ISO 2943
Max working pressure:
32.000.000 Pa (320 bar)
Testing pressure:
42.000.000 Pa (420 bar)
Burst pressure:
84.000.000 Pa (840 bar)
-20 t o + 1 1 0o c
600.000 Pa ±10% (6 bar)
(from opening)
Compatible with mineral oils such as
HH,HM,HR,HV,HG according
to ISO 6743/4)
63
HIGH PRESSURE FILTERS
FHMFHM series 42
I
M
G
Flows have been calculated just in order to obtaina pressure drop ∆p ≤ 120.000 Pa (1.2 bar) withmineral oil kinematic viscosity 30 cSt and 860kg/m3 density.
1
2
3
4
5
3/4” BSP
1” BSP
3/4” NPT
1” NPT
SAE12 - 1 1/16”-12UN
SAE16 - 1 5/16”-12UN
M 10
M 10
3/8” UNC
3/8” UNC
3/8” UNC
3/8” UNC
Type A E (depth 15mm)
RECOMMENDED FLOWSGlass fibre elements
THREADED CONNECTIONS
6
7
8
9
3/4”SAE -3000 PSI/M
1”SAE -3000 PSI/M
3/4”SAE -3000 PSI/UNC
1”SAE -3000 PSI/UNC
M 10
M 10
3/8” UNC
3/8” UNC
M 10
M 10
3/8” UNC
3/8” UNC
22.5
26.2
22.5
26.2
47.6
52.4
47.6
52.4
Type Connection I M G E(depth 15mm)
FLANGED CONNECTIONS
1
2
277
390
FHM421
FHM422
Type H (mm) Length
421
421
421
421
422
422
422
422
F03
F06
F10
F25
F03
F06
F10
F25
FHM Replaceelement
55
65
80
104
100
113
135
170
Flow (L/min)X series
38
55
60
75
80
90
115
145
Flow (L/min)Y series
3,9
3,9
3,9
3,9
5,6
5,6
5,6
5,6
Weight (Kg)
LENGTH
A/F30
A
113113
94
ø78
12
5H
47
E
57
10
ø8.5
40
50.5
51.5
1/2
”BS
P
33
65
HIGH PRESSURE FILTERS
FHMFHM series 28
Flows have been calculated just in order to obtaina pressure drop ∆p ≤ 120.000 Pa (1.2 bar) withmineral oil kinematic viscosity 30 cSt and 860kg/m3 density.
1
2
3
4
5
1/2” BSP
3/4” BSP
1/2” NPT
3/4” NPT
SAE8 - 3/4”-16UNF
SAE12 - 1 1/16”- 12UN
M 8
M 8
5/16” UNC
5/16” UNC
5/16” UNC
5/16” UNC
Tipo / Type A E (depth 15mm)
RECOMMENDED FLOWS(Glass fibre elements)
THREADED CONNECTIONS
AT
1
2
3
189
219
319
FHM281
FHM282
FHM283
Tipo / Type H (mm) Length
281
281
281
281
282
282
282
282
283
283
283
283
F03
F06
F10
F25
F03
F06
F10
F25
F03
F06
F10
F25
FHM Replaceelement
17
20
35
50
26
40
55
80
38
50
70
95
Flow (L/min)X series
15
18
33
47
22
29
50
70
32
40
60
85
Flow (L/min)Y series
2,65
2,65
2,65
2,65
3,2
3,2
3,2
3,2
4,7
4,7
4,7
4,7
Weight (Kg)
LENGTHS
A
43
H1
00
ø70
E
46
87
68
A/F 30
13.510
ø8.5
30
40
43
.54
3.5
1/2
” BS
P
64
HIGH PRESSURE FILTERS
FHMPressure Drops
(according to ISO 3968)
0
10
20
30
40
50
60
0 20 40 60 80 100
flow(L/min)
de
lta
P(K
Pa
)
0
300
600
900
1200
0 10 20 30 40 50
flow(L/min)
de
lta
P(K
Pa
)
0
140
120
100
80
60
40
20
160
180
200
0 10 20 30 40 50 60
flow(L/min)
de
lta
P( K
Pa
)
0F3 6
F0 F01
5F2
0
20
40
60
80
100
120
140
160
180
200
0 20 3010 40 50 7060 80 90 100
flow(L/min)
de
lta
P( K
Pa
)
F03
F06 1F0
25F
0
140
120
100
80
60
40
20
160
180
200
0 10 20 30 40 50 60
flow(L/min)
de
l ta
P( K
Pa
)
F03 06F
01F
F 52
0
20
40
60
80
100
120
140
160
180
200
0 20 3010 40 50 7060 80 90 100
flow(L/min)
de
lta
P(K
Pa
)
F03 F60 F
01
F25
∆P HOUSINGS BY-PASS
∆P X ELEMENTS∆P Y ELEMENTFHM 281 series
∆P X ELEMENTS ∆P Y ELEMENTSFHM 282 series
FHM series 28
66
HIGH PRESSURE FILTERS
FHMPressure Drops
(according to ISO 3968)
0
140
120
100
80
60
40
20
160
180
200
0 20 40 60 80 100 120
flow(L/min)
delt
aP
(KP
a)
F03
F06 10F
25F
0
140
120
100
80
60
40
20
160
180
200
0 20 40 60 80 100 120
flow (L/min)
delt
aP
(KP
a)
F30 F06 0
F1
F25
0
10
20
30
40
50
60
70
80
0 20 40 60 80 100 120 140 160 180 200flow(L/min)
delt
aP
(KP
a)
Con valvolaReverse flow
0
400
200
800
600
1200
1000
1600
1400
0 20 40 60 80 100flow(L/min)
delt
aP
(KP
a)
0
100
200
300
400
500
600
0 20 40 60 80 100flow(L/min)
delt
aP
(KP
a)
0
140
120
100
80
60
40
20
160
180
200
0 20 40 60 80 100 120 140
f/low(L/min)
delt
aP
(KP
a)
03F6
F0 F01
F 52
0
140
120
100
80
60
40
20
160
180
200
0 20 40 60 80 100 120 140
f/low (L/min)
delt
aP
(KP
a)
F30
F06F
0125
F
0
20
40
60
80
100
120
140
160
180
200
0 20 40 60 80 100 120 140 160 180
flow(L/min)
delt
aP
(KP
a)
3F0 06
F
0F1
25F
0
20
40
60
80
100
120
140
160
180
200
0 20 40 60 80 100 120 140 160 180
flow(L/min)
delt
aP
(KP
a)
F30 06
F 0F1
5F2
∆P X ELEMENTS ∆P Y ELEMENTSFHM 421 series
∆P X ELEMENTS ∆P Y ELEMENTSFHM 283 series
∆P HOUSINGS BY-PASS REV. FLOW VALVE
∆P X ELEMENTS ∆P Y ELEMENTS
FHM 422 series
FHM series 42
67
HIGH PRESSURE FILTERS
FHM
Ordering Info
F H M 281 T25 Y N S 3
EHP 421 F03 Y N
Nominal Size
281
282
283
421
422
-
1
2
3
4
5
6
7
8
9
Filtration Element
A FHM28
1/2” BSP
3/4” BSP
1/2” NPT
3/4” NPT
SAE8 3/4” - 16UNF
SAE12 1 1/16” - 12UN
3/4” BSP
1” BSP
3/4” NPT
1” NPT
SAE12 1 1/16” - 12UN
SAE16 1 5/16” - 12UN
3/4” SAE-3000PSI/M
1” SAE-3000PSI/M
3/4” SAE-3000PSI/UNC
1” SAE-3000PSI/UNC
FHM42
-
C10
C25
F03
F06
F10
F25
T10
T25
10 µm
25 µm
3 µm
6 µm
10 µm
25 µm
10 µm
25 µm
Without filtration elements
Resin treated cellulose ßx>2
Resin treated cellulose ßx>2
Inorganic fibre ßx > 200
Inorganic fibre ßx > 200
Inorganic fibre ßx > 200
Inorganic fibre ßx > 200
Steel Aisi 304 Wire mesh
Steel Aisi 304 Wire mesh
Seals
N
V
S
R
P
Q
Buna-N
Viton
∆P. Cartridge
X
Y
2.000.000
(20 Bar)
21.000.000
(210 Bar)
for filters with By-pass
for filters without By-pass
By-pass valve
Without By-pass
By-pass ∆p 6 bar
With reverse flow valve
With reverse flow valve + By-Pass
(Replacement element)
CONNECTIONS
68
PIPE CLAMPS
69
Pipe Clamps
FC
The design of pipe clamps and the choice of standard or Heavy duty pipe clamps body material, varyaccording to the loading, the shearing forces and the torque so as to provide for rigid installation.Shearing forces diagrams for various tube sizes are given below for standard and heavy duty pipe clamps for polypropyelene, polyamide and aluminium.
shearing forc
es P
(kp)
shearing forc
es P
(kp)
100
200
300
400
5 10 15 20 25 30 35 40PP ALU
1000
2000
1000
2000
3000
4000
5000
6000
7000
8000
20 40 60 80 100 120 140 160 180 200 220 240
10
20
30
Torq
ue M
D (
mkp)
STANDARD SERIES HEAVY SERIES
SHEARING FORCES DIAGRAM
PP ALU
c
a
b
b
a
a
a
b b
Clamp Body Properties
Polypropyelene (PP)Density: 0.906gm/cm
Polyamide AluminiumDensity : 2.65gm/cm
3 3
Tensile yeild stress ASTM D 638
Flexural module ASTM D 790
Izod impact strength ASTM D 256Hardness
Melting pointVicat softening pointMax. temp resistance
Weak acids, solventsBenzene,mineral oilsalcohol,other oils, sea water
370 Kg/cm
16,000 Kg/cm
7.5 Kg.cm/cmR70
160 C150 C
-30 C to 90 C
cond. consistentcond consistent
consistent
750 Kg/cm
4.5 Kg.cm/cmR120
220 C210 C
-40 C to 180 C
cond consistentcond consistentcond consistent
3,300 Kg/cmYield 3,100 Kg/cm@ 12 % elongation
upto 400 C
MATERIAL SPECIFICATION
70
Standard Clamps
FCS
GROUP
PIPE SIZE (a)
mmOD
INCHOD
INCHNB
b c d g
ASSEMBLYWITH SCREW
TOP PLATE ANDHEX. BOLT
PART NO. ASSY. PART NO.
FCS.06
FCS.08
FCS.1.06
FCS.1.08
FCS.10 FCS.1.10
FCS.06-1A FCS.1.06-1A
FCS.08-1A FCS.1.08-1A
FCS.10-1A FCS.1.10-1A
FCS.12 FCS.1.12
FCS.14 FCS.1.14
FCS.15 FCS.1.15
FCS.16 FCS.1.16
FCS.18 FCS.1.18
FCS.19 FCS.1.19
FCS.20 FCS.1.20
FCS.22 FCS.1.22
FCS.25 FCS.1.25
FCS.28 FCS.1.28
FCS.30 FCS.1.30
FCS.32 FCS.1.32
FCS.35 FCS.1.35
FCS.38 FCS.1.38
FCS.42 FCS.1.42
FCS.48 FCS.1.48
FCS.50 FCS.1.50
1
1A
2
3
4
5
6
6
8
10
6
8
10
12
14
15
16
18
19
20
22
25
28
30
32
35
38
42
48
50
28 26 - 1
34 26 1320
40 33 126
43 35 133
57 42 240
70 60 252
86 69 3662
1
½
¾
1
¼½
½1
1
1
¼1
½
½
¼
3 8 1 8
3 8 1 8
¼
5 8 3 8
¾
g
30
a
3
c
11 10
b
d
ag
3b
c
30
m 6 bolts
71
Heavy Clamps
FCH
GROUPPIPE SIZE (a)
MMOD.
INCHO.D.
MMN.B.
6 1/4
8
10 3/8
12 1/2
1/2
14 1/4
15
16 5/8 3/8
7
8
18
20
22
25
28
30
35
38
42
50
60
65
70
75
90
100
150
168
493
56
70
3/4
7/8 1/2
1
9 84
3/4
1
1 1/4
1 1/2
2
2 1/2
8
6
5
4
3 1/2
3
2 1/2
2
1 1/2
1 1/4
3 1/2
3
4 1/2
5 1/2
6 1/2
4
613
14
12
11
10
b c w L t d m g
32 30 73 8 33 M10 2
48 30 85 8 45 M10 2
115 90 45 140 10 90.5 M12 3
152 120 60 180 10 122 M16 3
205 170 80 225 15 168 M20 4
250 200 90 270 15 205 M24 4
330 270 125 340 25 265 M30 4
60 30 100 8 60 M10 2
TOP PLATE &HEX, BOLTASSY. PARTNO.
Wt/PIECKG.
FCH.1.06
FCH 1.08
FCH 1.10
FCH 1.12
FCH 1.14
FCH 1.15
FCH 1.16
FCH 1.18
FCH 1.20
FCH 1.22
FCH 1.25
FCH 1.28
FCH 1.30
FCH 1.33
FCH 1.38
FCH 1.42
FCH 1.48
FCH 1.60
FCH 1.65
FCH 1.70
FCH 1.75
FCH 1.90
FCH 1.100
FCH 1.150
FCH 1.168
FCH.1.219
FCH 1.63
FCH 1.73
FCH 1.89
FCH 1.114
FCH 1.141
0.35
0.46
0.53
1.80
3.00
8.00
11.00
24.00
t
t
c
L
a
g
b
d
w
m(bolts)
72
Twin Clamps
FCTFCFC
Pipe size
a b c g L t mPart No.Group
1T6 to 12 mm
1/4” to 1/2”
2T12.7 to 18mm
1/2” to 5/8”
3T19 to 25.4 mm
3/4” to 1”
4T
5T
26.9 to 30 mm
1 1/16” to 1 3/16”
32 to 42 mm
1 1/4” to 1 5/8”
36
53
67
80
106
27
27
37
40
53
0.6
0.7
0.7
0.7
0.7
37
55
70
85
110
3
5
5
5
5
M6
M8
M8
M8
M8
FCT.IT.xxx
FCT.2T.xxx
FCT.3T.xxx
FCT.4T.xxx
FCT.5T.xxx
HOW TO ORDER TWIN CLAMPSFCT
(A) For Twin Clamps
Designation forTwin Pipe Clamps:
Twin Clamp Group1T to 5T
O.D. of Pipe/Tube: in mm/inches
MaterialPolypropylene:Polyamide UL:Aluminium AI Si 12:
NO SYMBOLPA
ALU
b
c
t
t
30L
h
a a g
m(bolts)
73
How to order
FCHOW TO ORDER STANDARD CLAMPS
(A) For Single Clamps (B) For Multiple Clamps on Single Weld Plate
Number of Clamps:
Vertical Mounting:Horizontal Back-to-Back:Horizontal Side-to-Side:
VHBHR
Designation ofStandard Duty Pipe Clamps:
Mutiple Clamps: Are always ordered withWeld Plate and Hex Bolts
Outside Diameter ofPipe/Tube in their order:(a) For Vertical Mounting: Starting from Wild Plate up(b) For Horizontal Mounting: Starting fromleft to right
MaterialPolypropylene:Polyamide UL:Aluminium AI Si 12:
NO SYMBOLPA
ALU
Designation forStandard Duty Pipe Clamps:
For Assembly withScrews:
NO SYMBOL
NO SYMBOLPA
ALU
For Assembly withWeld Plate and Hex Bolts:
1
O.D. of Pipe/Tube: in mm
For Channel Mountingwith 'T' Nuts:
'C'
MaterialPolypropylene:Polyamide UL:Aluminium AI Si 12:
FCS - FCS
HOW TO ORDER HEAVY CLAMPS(B) For Multiple Clamps on Single Weld Plate
Number of Clamps:
Vertical Mounting:Horizontal Back-to-Back:Horizontal Side-to-Side:
VHBHR
Designation of Heavy Duty Pipe Clamps
Multiple Clamps: Are always ordered withWeld Plate and Hex Bolts
Outside Diameter for Pipe/Tube in their order:(a) For Vertical Mounting:Starting from Weld Plate up(b) For Horizontal Mounting:Starting from left to right
MaterialPolypropylene:Polyamide UL:Aluminium AI Si 12:
NO SYMBOLPA
ALU
FCHFCH
(A) For Single Clamps
Designation forHeavy Duty Pipe Clamps:
Heavy Duty Pipe Clamps: Are onlysupplied with Top Plates and Hex Bolts:
O.D. of Pipe/Tube: in mm
For Channel Mounting with 'T' -nuts: 'CH'
MaterialPolypropylene:Polyamide UL:Aluminium AI Si 12:
NO SYMBOLPA
ALU
74
75
Notes
Administrative Office
FFP Products17, Sai niketan,Chandavarkar lane,Borivali west, Mumbai 400 092Maharashtra, INDIA
Telephone+91 22 [email protected]
High Pressure Filters
www.ffpproducts.com