7
1 Beam test at DESY Date: 01/12 – 19/12 Place: DESY, Testbeam area 24 Time schedule and more information available: http://desyntwww.desy.de/~testbeam

1 Beam test at DESY Date: 01/12 – 19/12 Place: DESY, Testbeam area 24 Time schedule and more information available: testbeam

  • View
    217

  • Download
    0

Embed Size (px)

Citation preview

1

Beam test at DESY

Date: 01/12 – 19/12Place: DESY, Testbeam area 24

Time schedule and more information available:http://desyntwww.desy.de/~testbeam

2

Test beam area 24

movabletable fixture for

scintillatorsmagnet(not used)

Good conditionsin test beam area- plenty of space- no problem with usage of gas-comfortable counting room

3

Detectors and services4 Warsaw modules are shipped from Nikhef toHeidelberg this week.

Mechanical support and gas system can be provided by Heidelberg.

Most effort still necessary for electronics(see next slides). available manpower is limited!

4

Necessary Equipment (Hardware)

4 front end boxes missing

1 distribution box (including I²C) missing

TTC-system : TTCvi + TTCvx available

1 OrxCard + 12 LVDS Adapter available

2 Stratix Boards + Adapter available

5

Necessary Equipment (Hardware)

Power supplies : missing

± 5V / 50A

2.5V / 5A

3.3V /10A

3 PCs available

2 Scintillator + Nim crate available

Cooling missing

(Peltier element + CPU cooler )

6

Necessary Equipment (Software)

Stratix board code for 6 links available

in Dortmund??

Readout software for the available

Stratix Board via PCI-Bus

DAQ monitoring missing

I²C control available

TTC control available

7

Many components available,

but system test is mandatory!