Upload
claire-casey
View
214
Download
0
Tags:
Embed Size (px)
Citation preview
1
ACR Dose Index Registry
Laura P Coombs, PhD
2
How does it work?
3
Participation processSign Participation
Agreement and complete registration
form
Get set up and send data
• Install software• Configure scanners• Map exams
Obtain reports
4 4
5 5
6
ACR.ORG/NRDR
6
7
8
9
1010
11
SSDE Results
All DIR sites
RPID Short Name N 25th %'ile Median 75th %'ile
CT ABD PELVIS W IVCON 13616 15 22 38
CT ABD PELVIS WO IVCON 7307 15 21 30
CT CHST W IVCON 5961 15 28 47
CT CHST WO IVCON 5380 8 14 20
12
CTDIvol Results
All DIR sites
RPID Short Name N 25th %'ile Median 75th %'ile
CT ABD PELVIS W IVCON 105518 10 15 22
CT ABD PELVIS WO IVCON 37465 10 16 22
CT CHST W IVCON 32889 9 13 20
CT CHST WO IVCON 36075 7 11 16
CT HEAD BRN WO IVCON 149719 46 56 66
13
DLP Results
All DIR sites
RPID Short Name N 25th %'ile Median 75th %'ile
CT ABD PELVIS W IVCON 105517 468 703 1034
CT ABD PELVIS WO IVCON 37465 496 765 1091
CT CHST W IVCON 32888 286 429 671
CT CHST WO IVCON 36074 236 373 537
CT HEAD BRN WO IVCON 149714 645 832 1023
14
15
16
17
18
19
Mapping Exam Names• Exam names mapped to Radlex Playbook
– http://playbook.radlex.org
• ACR used RadMapps to map all exam names currently in the registry– ~ 21,000 unique exam names
• New facilities may choose to use RadMapps or may use mapping tool on website
19
2020
21
SSDE
• New version of TRIAD (4.0) allows sites to submit localizer images along with Dose Report
21
22
SSDE
22
• Algorithm developed by Duke physicists will measure patient thickness from localizer
23
SR vs Dose sheet
Frequency Percent
SR 550326 29
Dose Sheet 1372331 71
24
% SRs Transmitted
Percent SRs
# of Facilities
0% 134
1-49% 37
50-99% 27
100% 7
Total 205
25
Information Needed• More detail on IR
– % or level of use
• Dual energy– what is reported in terms of kVp?
• Can clinicians view SR?