Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
17288 1
1-3 OTTER STREET
COLLINGWOOD, VIC 3066
SUSTAINABILITY MANAGEMENT PLAN
Date: 08 July 2021
Document Number: LCE21182
1-3 OTTER STREET, COLLINGWOOD
SUSTAINABILITY MANAGEMENT PLAN
LCE21182 2
DOCUMENT ISSUE REGISTER
PROJECT: 1-3 Otter Street, Collingwood, VIC 3066
PROJECT REF: 21182
REVISION DESCRIPTION DATE ISSUED AUTHOR REVIEWED
Town Planning Issue 08.07.2021 AG MM
1
1-3 OTTER STREET, COLLINGWOOD
SUSTAINABILITY MANAGEMENT PLAN
LCE21182 3
CONTENTS
1. INTRODUCTION .................................................................................................................................. 4
2. KEY ESD INITIATIVES ........................................................................................................................... 4
3. PROJECT INFORMATION .................................................................................................................... 5
3.1 DESCRIPTION OF DEVELOPMENT ...................................................................................................... 5
4. SUSTAINABLE DESIGN ASSESSMENT IN THE PLANNING PROCESS (SDAPP) .................................... 6
4.1 SDAPP ................................................................................................................................................. 6
4.2 YARRA PLANNING SCHEME CLAUSE 22.17 ...................................................................................... 7
5. SDAPP ASSESSMENT FRAMEWORK: BESS .......................................................................................... 8
6. ESD INITIATIVES ................................................................................................................................. 10
6.1 MANAGEMENT ................................................................................................................................. 10
6.2 INDOOR ENVIRONMENT QUALITY .................................................................................................. 11
6.3 ENERGY EFFICIENCY ........................................................................................................................ 12
6.4 TRANSPORT ....................................................................................................................................... 13
6.5 WATER EFFICIENCY .......................................................................................................................... 14
6.6 ECOLOGY ......................................................................................................................................... 15
6.7 EMISSIONS - STORMWATER MANAGEMENT ................................................................................... 16
6.8 WASTE MANAGEMENT .................................................................................................................... 17
7. SUMMARY OF ESD PERFORMANCE ................................................................................................. 18
APPENDIX A – BESS REPORT .............................................................................................................................. 19
APPENDIX B – PRELIMINARY NATHERS ASSESSMENT ....................................................................................... 20
APPENDIX C – DAYLIGHT MODELLING ............................................................................................................ 21
1-3 OTTER STREET, COLLINGWOOD VIC 3066
SUSTAINABILITY MANAGEMENT PLAN
17288 4
1. INTRODUCTION
This Sustainability Management Plan (SMP) provides an overview of the sustainability initiatives that
have been assessed for inclusion in the proposed mixed use development located at 1-3 Otter Street,
Collingwood, VIC 3066.
This SMP provides a comprehensive summary of the assessment of this development against the
applicable ESD frameworks at the planning stage.
An SMP identifies beneficial, easy to implement and best practice sustainability initiatives in line with
the Sustainable Design Assessment in the Planning Process (SDAPP) framework. This includes:-
▪ A practical approach to assessing sustainable development matters during the planning permit
application process.
▪ The consistent inclusion of key environmental performance considerations into the planning
approvals process.
▪ A guide to achieving more sustainable building outcomes for the long–term benefit of the
wider community.
The initiatives proposed provide a holistic approach to sustainability within the built environment with a
focus on energy efficiency, indoor environment quality, management practices, stormwater quality and
water efficiency.
2. KEY ESD INITIATIVES
The key ESD initiatives in the proposed development will include:
▪ Development will exceed the minimum NCC NatHERS requirements of 6-star average/
individual unit not less than 5 star minimum rating requirement and TARGET a minimum 7-star
average with no unit below the 6 star minimum rating.
▪ High-performance fabric and glazing is proposed to reduce solar heat gain and conduction
losses, providing reduced annual energy consumption and reduced peak electrical demand.
▪ Excellent access to public transport and the provision of cyclist facilities.
▪ Excellent indoor environment quality through provision of adequate daylighting to a large
extent of the nominated area, natural ventilation, high-quality LED lighting, low TVOC emission
materials (paints, sealants, wood products) etc.
▪ High water efficiency fixtures and fittings (Water Efficiency Labelling WELS star ratings)
reducing the dependence on potable water use.
▪ Efficient heating/ cooling and hot water systems will ensure significant reductions in
consumption of electricity.
▪ A min 10kW Solar PV system is proposed to serve the common areas of the development.
▪ The development proposes communal spaces on rooftop to facilitate interaction between
building occupants.
On the basis of our review, the application of the Built Environment Sustainability Scorecard (BESS) the
development achieves a BESS score of 60%. The project not only exceeds the minimum planning permit
BESS requirement of 50% but also demonstrates much higher performance with a “Best Practice” BESS
outcome.
Please refer to Appendix A for further information regarding the determination of a development
average BESS score.
LCE21182 5
3. PROJECT INFORMATION
3.1 DESCRIPTION OF DEVELOPMENT
Table 1 – Project Details
Building Elements Project Details
Site Address 1-3 Otter Street, Collingwood 3066
Description Basement – Car Park
Ground Level – Commercial, Townhouses
Mezzanine- Commercial
Level 1– Level 6 – Apartments
Municipality City of Yarra
Building Classification Class 2 Apartments and Class 5 Commercial
GFA ~6753 m2
Site Area 733 m2
Figure 1 displays the site location and general arrangement of the proposed development.
Figure 1 – General Site Location and Arrangement
LCE21182 6
4. SUSTAINABLE DESIGN ASSESSMENT IN THE PLANNING PROCESS (SDAPP)
4.1 SDAPP
Sustainability or Ecological Sustainable Development (ESD) are terms that are typically used to describe
the intent to balance the elements of society, economics and the environment.
Sustainable Design Assessment in the Planning Process (SDAPP) is the framework used to achieve ESD
outcomes in the planning process. This process specifically responds to the State Policy Planning
Framework (SPPF), local Structure Plans, Municipal Strategic Statements and planning overlays.
SDAPP was developed to achieve a harmonised approach to ESD outcomes within the planning process
and;
• Recognises the role of the Responsible Authority as a statutory authority for planning matters;
• Provides a framework for consideration of sustainable design elements of planning
applications;
• Offers a consistent method for identifying opportunities for improved environmental building
performance; and
• Ensures that sustainability is considered at the very early design phase.
Through local planning requirements, SDAPP framework calls up a number of sustainability rating tools
which can be used to demonstrate performance criteria have been achieved for the purposes of
planning assessment. These include;
• Built Environment Sustainability Scorecard (BESS): This tool was developed by the
Municipal Association of Victoria (MAV) and is only used within Victoria and limited to the
planning process only.
• Green Star Design & As-Built: This tool is the industry standard green building tool and was
developed by the Green Building Council of Australia (GBCA). Green Star is used broadly by the
property and construction sector, nationally, to drive sustainability outcomes.
SDAPP and the preparation of an SMP outlining performance against referenced sustainability rating
frameworks addresses the specific requirements of the planning scheme as applicable to the Relevant
Authority.
For this development the applicable planning scheme policy specific to ESD is outlined within Table 2.
Table 2 – Sustainability Policy & Assessment Frameworks
Responsible Authority or LGA Planning Scheme Policy
City of Yarra Clause 22.17 Environmentally Sustainable
Development
The particulars of the City of Yarra Planning Scheme Clause 22.17 are discussed below.
LCE21182 7
4.2 YARRA PLANNING SCHEME CLAUSE 22.17
Clause 22.17 applies within the City of Yarra to residential and non-residential development. The
overarching objective is that development should achieve “best practice” in ESD from the design stage
through to construction and operation.
In the context of this policy “best practice” is defined as:
“A combination of commercially proven techniques, methodologies and systems, appropriate to the scale
of development and site-specific opportunities and constraints, which are demonstrated and locally
available and have led to optimum ESD outcomes. Best practice in the built environment encompasses the
full life of the build.”
The application requirements contained in Clause 22.17 are outlined in Table 3. Based on development
type and size, these define the application requirements and the permissible ESD assessment tools that
can be used.
Table 3 – ESD Application Requirements
Per Clause 22.17, this development is utilising the submission of a Sustainability Management Plan
using the Built Environment Sustainability Scorecard (BESS) rating system as the assessment
framework as outlined in Table 4.
LCE21182 8
Table 4 – ESD Application Response (1-3 Otter Street)
Development
Type
Size Application Document Assessment Tool
Accommodation/
mixed use with
Residential
component
Development of 10
or more dwellings
Sustainability Management
Plan
BESS
BESS is used for this project, mainly for the following reasons:
• BESS is designed specifically to support the SDAPP framework of the planning which is
consistent with the planning scheme policy Clause 22.17 Environmentally Sustainable
Development of the City of Yarra.
• BESS rating tool is more familiar to the Councils and is a standard approach that is largely
supported by the Council.
• Green Star is a more complex tool that requires rigorous documentation throughout the
project which adds to the project time and cost
• Green Star has more stringent requirements and scoring system for categories like Energy
performance etc. Which can be much easily achieved within BESS without impacting the
objective of “best practice’” target of the project.
5. SDAPP ASSESSMENT FRAMEWORK: BESS
The Built Environment Sustainability Scorecard (BESS) tool is a performance-based tool with a number
of categories and design criteria, similar to other sustainability benchmarking systems. BESS includes
the following sustainability categories:
• Management
• Energy
• Water
• Stormwater
• Indoor Environment Quality (IEQ)
• Transport
• Waste
• Urban Ecology, and
• Innovation
The required design criteria or design performance contributes to an overall percentage (%) category
score. Summation of the individual category scores provides an overall development score. To comply
with minimum requirements, a development must achieve a BESS score of not less than 50%. In
addition, minimum performance must be achieved within the following categories:
LCE21182 9
• Energy – 50%
• Water – 50%
• Stormwater – 50%
• Indoor Environment Quality – 50%
Per SDAPP and Clause 22.17 of the City of Yarra Planning Scheme, the 1-3 Otter Street development
has defined specific ESD initiatives to exceed the minimum BESS outcome. This is summarised in Table 5
(over page).
Table 5 – 1-3 Otter Street, Collingwood BESS Target
Planning Scheme Policy Policy Objective BESS Target
City of Yarra
Clause 22.17 Environmentally
Sustainable Development
‘development should achieve
best practice in environmentally
sustainable development’
> 50%
(Best Practice)
Please note that the proposed BESS pathway and ESD initiatives are presented for transparency to
identify initiatives which can be readily committed to and have been incorporated in the design at this
stage. However, should activities within detailed design indicate that an initiative cannot be obtained,
such impacts will be compensated through the identification of other initiatives to maintain the same
BESS score commitment.
LCE21182 10
6. ESD INITIATIVES
6.1 MANAGEMENT
Management opportunities during design, construction and operation of a building can have a
significant impact on environmental performance. It is highly important that appropriate practices and
design features are implemented to ensure the facility can be operated per design intent.
Key Issues
The key issues relevant to Management within this development include:
▪ ESD professional
▪ Preliminary thermal performance modelling
▪ Metering
▪ Building users guide
The proposed ESD initiatives address these issues.
Proposed ESD Initiatives
1. ESD Professional
The development has engaged an ESD Consultant to facilitate the implementation of the ESD
commitments and BESS pathway throughout all stages of the project.
2. Preliminary Thermal Performance Modelling
For residential spaces the development uses NatHERS assessment to demonstrate that the
development will exceed the minimum 6-star average/ individual unit not less than 5 star minimum
rating requirement and TARGET a minimum 7-star average with no unit below the 6 star minimum
rating. Thermal modelling is being used to inform passive design at the early design stages of the
project. Refer Appendix B for detailed results.
For the non-residential spaces the development uses NCC Façade Calculator v1.1 to perform
preliminary Section J NCC 2019 Volume 1 – Façade Assessment to inform passive design from the early
stages of design. The preliminary assessment indicates that the thermal performance of the wall-glazing
construction will meet the performance of the Reference case and achieve a complaint.
3. Sub-Metering
Individual commercial tenants will be provided with separate minimum authority metering and all the
major common services (eg. DHW, HVAC, Lifts etc.) will be sub metered separately. Smart metering will
be provided to all apartments for energy consumption tracking and monitoring.
4. Building Users Guide
To encourage and recognise initiatives that will help building users to use the building more efficiently a
building users guide will be prepared for building occupants.
LCE21182 11
6.2 INDOOR ENVIRONMENT QUALITY
Indoor Environment Quality (IEQ) is important for the health and well-being of all building occupants
and users. IEQ can be measured utilising metrics such as air quality, lighting and acoustics. Buildings
with higher levels of IEQ have been found to promote general physical and mental health.
Key Issues
The key issues relevant to indoor environment quality within this development include:
▪ Daylight
▪ Natural Ventilation
▪ Outside air
▪ Hazardous material and VOC
The proposed ESD initiatives address these issues.
Proposed ESD Initiatives
1. Daylight.
All habitable spaces within the proposed development receive daylight via windows to the external,
ensuring that all areas receive some extent of natural light. Preliminary daylight modelling indicates that
100% of all bedrooms achieve BESS IEQ 1.2 daylight requirements and 80% of the commercial areas
achieve BESS IEQ 1.4 daylight requirements. Refer to Appendix C for details of the assessment.
2. Natural Ventilation
The development has ensured at least 60% apartments will have access to effective natural ventilation.
This is achieved through Effective cross ventilation or single sided ventilation such that:
- A breeze path lies between 2 ventilation openings either within the room or from one room to
another.
- Ventilation openings located either in opposite or adjacent external walls.
It is determined that 60% of dwellings achieve compliance with BESS natural ventilation requirements.
3. Outside air
For all non-residential areas of the development a minimum 50% increase in outside air will be available
to regular use areas compared to the minimum required by AS/NZS1668:2012.
4. Hazardous material and VOC
All paints, adhesives, sealants and carpets to meet stipulated Green Star VOC limits and all engineered
wood products to meet stipulated Green Star formaldehyde limits.
LCE21182 12
6.3 ENERGY EFFICIENCY
Energy efficiency is considered critical for ensuring that usage of non-renewable forms of energy is
minimised such that continued economic activity does not impact the natural environment.
Additionally, energy efficiency has a direct financial benefit, as it reduces exposure to real escalations in
energy costs.
1-3 Otter Street focuses on passive design features to improve energy efficiency; such features do not
consume operational energy and generally last the lifetime of the building > 50 years.
The development targets to achieve a development average of 7.0-Star NatHERS rating with no
apartment achieving less than 6.0 Stars via high performance building fabric and glazing. This exceeds
the minimum planning requirements.
These initiatives will result in reduced energy consumption and associated impacts of peak electrical
demand.
Key Issues
The key issues relevant to energy efficiency within this development include:
▪ Thermal envelope energy efficiency
▪ Energy efficient building services
▪ Peak electricity demand reduction
▪ Solar PV
▪ Carpark ventilation
The proposed ESD initiatives address these issues.
Proposed ESD Initiatives
1. Thermal Envelope Enhancement
Non-Residential Spaces of the development will achieve an enhanced performance of the building
fabric by demonstrating improvement in required NCC2019 insulation levels to the building fabric
elements roof, walls, ceilings, floor, glazing system etc. This will result in reductions in heating and
cooling energy consumption below the reference case (NCC Section J 2019) and reduced peak electrical
demand reduction.
The Preliminary façade assessment conducted using NCC 2019 Façade calculator v1.1 indicates that the
proposed wall-glazing construction will meet the minimum performance requirements.
Residential Class 2 areas of the development will achieve an area weighted NatHERS rating of not less
than 7-Stars, exceeding the minimum requirements of the NCC providing for reduced HVAC energy
consumption and reduced peak electrical demand reduction. This includes proposing high performance
roof, wall and floor insulation and glazing system.
Please refer to Appendix B for preliminary NatHERS modelling results.
2. Energy Efficient Building Services – High Efficiency LED Lighting
The development is to incorporate high efficiency light fittings and effective pragmatic control
strategies.
LCE21182 13
For the Residential areas provisions of internal lighting with maximum illumination power density
(W/m2) in at least 90% of the relevant building class at least 20% lower than required by Table J6.2a of
the NCC 2019 Vol 1 (Class 2-9) and Clause 3.12.5.5 NCC 2019 Vol 2 (Class 1 & 10.
For the Non-Residential areas provisions of maximum illumination power density (W/m2) in at least
90% of the area of the relevant building class meet the requirements in Table J6.2a of the NCC 2019
Vol1.
4. Energy Efficient Building Services – Heating & Cooling Systems
Due to the size of the dwellings, reverse-cycle heat-pumps provided to all residential dwellings will be
of the multi-split type (e.g. one outdoor condenser with multiple indoor units). These units are excluded
from the requirement to have “star ratings” however units selected for the development will provide an
Annual Energy Efficiency Ratio (AEER) for cooling of not less than 3.4 as determined from the GEMS
Registration Database (https://reg.energyrating.gov.au/comparator/product_types/).
5. Energy Efficient Building Services – DHW Systems
Domestic hot water will be provided by electric CO2 heat pump system.
6. Renewable Energy
A minimum 10kW Solar PV system will be provided for the apartments. This will be located on top of
the Roof plant pending further access provisions.
7. Carpark Ventilation
The carpark for the proposed development will provide with carbon monoxide monitoring to control
the operation and speed of ventilation fans.
6.4 TRANSPORT
Car usage within Australia is responsible for approximately 50% of total transport greenhouse gas
emissions. Additionally, the level of car usage greatly dominates over other forms of transport. Car
usage contributes to airborne pollutants and poor air quality.
To demonstrate the consideration of transportation at this development, the ‘WalkScore’ platform has
been used to determine access to surrounding facilities and public transport.
LCE21182 14
This development scores “Walker’s Paradise” with a Walk Score of 99 and an access to public transport
score of 93 “Rider’s Paradise”. This represents an excellent score in context of reducing transport related
emissions.
Key Issues
The key issues relevant to transport within this development include:
▪ Proximity to public transport and amenities
▪ Bicycle parking
▪ EV infrastructure
The proposed ESD initiatives address these issues.
Proposed ESD Initiatives
1. Public Transport & Amenities Proximity
As evidenced by the “Walkscore” the development is well situated for access to public transport and
amenities.
2. Bicycle Parking
In context of the excellent public transport and walk score, the development will meet the minimum
statutory bicycle parking requirement.
2. EV Infrastructure
The development will provide with facilities for electric vehicle charging, with appropriate signage and
charging infrastructure installed for atleast 1 parking space.
6.5 WATER EFFICIENCY
Water efficiency is deemed critical due to the growing needs of Melbourne’s population, and the
current wasteful actions of general households when it comes to potable water usage. Additionally,
water is a costly resource which is in turn becoming a financial burden.
1-3 Otter Street, Collingwood utilises high efficiency fixtures and fittings and water efficient appliances
to minimise the consumption of the water used.
Key Issues
The key issues relevant to water efficiency within this development include:
▪ Minimising amenity water demand
▪ Fire system test water consumption
▪ Landscape water efficiency
▪ Water sub-metering
The proposed ESD initiatives address these issues.
LCE21182 15
Proposed ESD Initiatives
1. Amenity Water Demand
Selection of fittings, fixtures and water consuming equipment is highly important for achieving a water
efficient building. All fixtures and fittings shall be selected as low flow with high Water Efficiency
Labelling (WELS) star ratings. Table 6 provides a summary of the minimum water efficiency
requirements of amenity fixtures and fittings.
Table 6 – Water Efficiency Requirements
Fixture / Fitting WELS Star Rating Maximum Flow/Flush
Performance
Shower Head ≥4-Star ≥4.5 l/min ≤6.0 l/min
Toilets/Water Closets ≥4-Star ≤3.5l/flush (average)
Taps – Bathroom ≥6-Star ≤6.0 l/min
Taps –Kitchen* ≥6-Star ≤6.0 l/min
^ Flow/flush rate takes precedent to WELS rating.
2. Water-Based Heat Rejection Avoidance.
The development will not utilise water-based heat rejection systems, with all HVAC being air-cooled.
This significantly reduces water demand and reduces risks associated with the heat rejection system
(e.g. microbial growth).
4. Rainwater Harvesting System
The development will include an underground rainwater tank ~6.0 kL with harvested rainwater with
reuse for the purposes of landscape only (to be confirmed in detailed design).
6.6 ECOLOGY
Urban ecology is about promoting and protecting ecosystems and biodiversity. Urban and agricultural
development has caused displacement of species and degradation of natural ecosystems.
Issues
The key issues relevant to ecology within this development include:-
▪ Site vegetation
▪ Communal Spaces
The proposed ESD initiatives address these issues.
Key ESD Initiatives
1. Site vegetation
To encourage and recognise the use of vegetation and landscaping the site is designed to include
Green areas on the terrace and podium level within the proposed development.
LCE21182 16
Figure 6.1 – Landscape (Level 1)
Figure 6.2 – Landscape (Roof Level)
2. Communal Spaces
To encourage and recognise initiatives that facilitate interaction between building occupants a Rooftop
communal space of ~120 sq.m has been proposed in the development.
6.7 EMISSIONS - STORMWATER MANAGEMENT
Due to the urbanisation of the Melbourne region and our large regional centres, a large proportion of
the land, which was once permeable soil, has been replaced with impervious surfaces presenting
significant implications for our existing stormwater systems and the environment.
Stormwater discharge direct into natural watercourses and bays without appropriate treatment presents
numerous pollution issues, associated with gross pollutants (such as litter, plastics and sediments),
nutrient pollution (nitrogen and phosphorous) which can contribute to algae blooms and free-oils
washed off roadways and carparks.
LCE21182 17
The key issues relevant to stormwater within this development include:-
▪ Stormwater quality management
▪ Stormwater discharge management
The proposed ESD initiatives address these issues.
Key ESD Initiatives
1. Stormwater Management
The project will meet the stormwater quality objectives of the City of Yarra Planning Scheme Clause
22.16 Stormwater Management (Water Sensitive Urban Design).
Compliance will be demonstrated through Civil MUSIC modelling during detailed design stages
accounting for hydraulics design and legal point of discharge considerations by civil engineer.
6.8 WASTE MANAGEMENT
Construction waste management is considered critical, with up to 40% of landfill in Australia being
attributed to the construction and demolition of buildings. On top of this, there is the on-going waste
from building occupants as a result of their everyday living and consumption. Managing and planning
for such waste is necessary to act on reducing the quantity going to landfill, whilst also ensuring that
materials which can be appropriately recycled are treated separately.
Issues
The issues relevant to waste management include:-
▪ Operation Waste Management Plan
1. Operational Waste Management
Development will include recycling waste storage facility located as conveniently as non-recyclable
waste storage. This must include separate waste collection points for general and recycled waste for the
development.
LCE21182 18
7. SUMMARY OF ESD PERFORMANCE
Table 7 provides a summary of the BESS performance within each category of the assessment tool.
Table 7 – BESS performance
BESS Category Category
Performance
Management 87%
Indoor Environment
Quality 57%
Energy 68%
Transport 76%
Water 57%
Stormwater 100%
Urban Ecology 10%
Waste 33%
Innovation 00%
TOTAL 60%
Please refer to Appendix A for the BESS pathway to the target ESD performance outcomes.
LCE21182 19
APPENDIX A – BESS REPORT
BESS Report Built Environment Sustainability Scorecard
This BESS report outlines the sustainable design commitments of the proposed development at 1-3 Otter St Collingwood VIC 3066. The BESS
report and accompanying documents and evidence are submitted in response to the requirement for a Sustainable Design Assessment or
Sustainability Management Plan at Yarra City Council.
Note that where a Sustainability Management Plan is required, the BESS report must be accompanied by a report that further demonstrates the
development's potential to achieve the relevant environmental performance outcomes and documents the means by which the performance
outcomes can be achieved.
Your BESS Score
Best practice Excellence
0% 10% 20% 30% 40% 50% 60% 70% 80% 90% 100%
60%Project details
Address 1-3 Otter St Collingwood VIC 3066
Project no F89346E2-R3
BESS Version BESS-6
Site type Mixed use development
Account [email protected]
Application no.
Site area 733 m2
Building floor area 3,289.2200000000003 m2
Date 07 July 2021
Software version 1.7.0-B.363
Performance by category Your development Maximum available
Building Type composition
Apartment Shop
BESS, 1-3 Otter St Collingwood 3066
Category Weight Score Pass
Management 5% 87%
Water 9% 57%
Energy 28% 68%
Stormwater 14% 100%
IEQ 17% 57%
Transport 9% 76%
Waste 6% 33%
Urban Ecology 6% 10%
Innovation 9% 0%
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 1 of 22
Buildings
Name Height Footprint % of total footprint
1 8 733 m2 100%
Dwellings & Non Res Spaces
Dwellings
Name Quantity Area Building % of total area
Apartment
Apt 5.02 2 156 m2 1 9%
Apt 5.01 2 161 m2 1 9%
Apt 4.01 2 117 m2 1 7%
Apt 4.03 2 106 m2 1 6%
Apt 4.02 2 115 m2 1 6%
Apt 2.01 2 84.8 m2 1 5%
Apt 2.06 2 68.5 m2 1 4%
Apt 2.05 2 71.2 m2 1 4%
Apt 2.03 2 71.9 m2 1 4%
Apt 2.02 2 76.7 m2 1 4%
TH Unit 2 1 121 m2 1 3%
TH Unit 1 1 118 m2 1 3%
Apt 2.07 2 46.0 m2 1 2%
Apt 2.04 2 43.5 m2 1 2%
Apt 1.01 1 83.7 m2 1 2%
Apt 1.06 1 80.1 m2 1 2%
Apt 1.05 1 83.5 m2 1 2%
Apt Unit 1.03 1 71.8 m2 1 2%
Apt Unit 1.02 1 76.3 m2 1 2%
TH Unit 3 1 87.0 m2 1 2%
Apt 1.07 1 45.7 m2 1 1%
Apt 1.04 1 51.3 m2 1 1%
Total 34 3,053 m2 92%
Non-Res Spaces
Name Quantity Area Building % of total area
Shop
Commercial 1 236 m2 1 7%
Total 1 236 m2 7%
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 2 of 22
Supporting information
Floorplans & elevation notes
Credit Requirement Response Status
Management 3.1 Individual utility meters annotated - Management 3.2 Individual utility meters annotated - Management 3.3 Common area submeters annotated - Water 3.1 Water efficient garden annotated - Energy 3.1 Carpark with natural ventilation or CO monitoring system - Energy 4.2 Floor plans showing location of photovoltaic panels as described. - Stormwater 1.1 Location of any stormwater management systems used in STORM or
MUSIC modelling (e.g. Rainwater tanks, raingarden, buffer strips) -
IEQ 1.2 If using BESS daylight calculator, references to floorplans and elevationsshowing window sizes and sky angles.
-
IEQ 1.5 Floor plans with compliant bedrooms marked - IEQ 2.1 Dwellings meeting the requirements for being 'naturally ventilated' - Transport 1.1 All nominated residential bicycle parking spaces - Transport 1.2 All nominated residential visitor bicycle parking spaces - Transport 1.3 Residential bicycle parking spaces at ground level - Transport 1.4 All nominated non-residential bicycle parking spaces - Transport 1.5 All nominated non-residential visitor bicycle parking spaces - Transport 2.1 Location of electric vehicle charging infrastructure - Waste 2.2 Location of recycling facilities - Urban Ecology 1.1 Size and location of communal spaces -
Supporting evidence
Credit Requirement Response Status
Management 2.2 Preliminary NatHERS assessments - Management 2.3 Preliminary modelling report - Management 2.3a Section J glazing assessment - Management 2.3b Preliminary modelling report - Energy 1.1 Energy Report showing calculations of reference case and proposed
buildings -
Energy 3.1 Provide a written explanation of either the fully natural carpark ventilation orcarbon monxide monitoring, describing how these systems will work, whatsystems are required for them to be fully integrated and who will beresponsible for their implementation throughout the design, procurementand operational phases of the building life.
-
Energy 3.6 Provide a written description of the average lighting power density to beinstalled in the development and specify the lighting type(s) to be used.
-
Energy 3.7 Provide a written description of the average lighting power density to beinstalled in the development and specify the lighting type(s) to be used.
-
Energy 4.2 Specifications of the solar photovoltaic system(s). - Stormwater 1.1 STORM report or MUSIC model - IEQ 1.2 If using an alternative daylight modelling program, a short report detailing
assumptions used and results achieved. -
IEQ 1.4 A short report detailing assumptions used and results achieved. - IEQ 1.5 A list of compliant bedrooms - IEQ 2.1 A list of naturally ventilated dwellings -
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 3 of 22
Credit summary
Management Overall contribution 4.5%
Water Overall contribution 9.0%
BESS, 1-3 Otter St Collingwood 3066
87%
1.1 Pre-Application Meeting 100%
2.2 Thermal Performance Modelling - Multi-Dwelling Residential 100%
2.3 Thermal Performance Modelling - Non-Residential 100%
3.1 Metering 100%
3.2 Metering 100%
3.3 Metering 100%
4.1 Building Users Guide 0%
Minimum required 50% 57% Pass
1.1 Potable water use reduction 40%
3.1 Water Efficient Landscaping 100%
4.1 Building Systems Water Use Reduction 100%
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 4 of 22
Energy Overall contribution 27.5%
Stormwater Overall contribution 13.5%
IEQ Overall contribution 16.5%
BESS, 1-3 Otter St Collingwood 3066
Minimum required 50% 68% Pass
1.1 Thermal Performance Rating - Non-Residential 37%
1.2 Thermal Performance Rating - Residential 50%
2.1 Greenhouse Gas Emissions 100%
2.2 Peak Demand 7%
2.3 Electricity Consumption 100%
2.4 Gas Consumption N/A Scoped Out
No gas connection in use
3.1 Carpark Ventilation 100%
3.2 Hot Water 100%
3.4 Clothes Drying 0%
3.6 Internal Lighting - Residential Multiple Dwellings 100%
3.7 Internal Lighting - Non-Residential 100%
4.1 Combined Heat and Power (cogeneration / trigeneration) N/A Scoped Out
No cogeneration or trigeneration system in use.
4.2 Renewable Energy Systems - Solar 92%
4.4 Renewable Energy Systems - Other N/A Disabled
No other (non-solar PV) renewable energy is in use.
Minimum required 100% 100% Pass
1.1 Stormwater Treatment 100%
Minimum required 50% 57% Pass
1.1 Daylight Access - Living Areas 0%
1.2 Daylight Access - Bedrooms 100%
1.3 Winter Sunlight 0%
1.4 Daylight Access - Non-Residential 80% Achieved
1.5 Daylight Access - Minimal Internal Bedrooms 100%
2.1 Effective Natural Ventilation 66%
2.3 Ventilation - Non-Residential 33% Achieved
3.4 Thermal comfort - Shading - Non-residential 0%
3.5 Thermal Comfort - Ceiling Fans - Non-Residential 0%
4.1 Air Quality - Non-Residential 100%
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 5 of 22
Transport Overall contribution 9.0%
Waste Overall contribution 5.5%
Urban Ecology Overall contribution 5.5%
Innovation Overall contribution 9.0%
BESS, 1-3 Otter St Collingwood 3066
76%
1.1 Bicycle Parking - Residential 100%
1.2 Bicycle Parking - Residential Visitor 100%
1.3 Bicycle Parking - Convenience Residential 100%
1.4 Bicycle Parking - Non-Residential 100%
1.5 Bicycle Parking - Non-Residential Visitor 100%
1.6 End of Trip Facilities - Non-Residential 0%
2.1 Electric Vehicle Infrastructure 100%
2.2 Car Share Scheme 0%
2.3 Motorbikes / Mopeds 0%
33%
1.1 - Construction Waste - Building Re-Use 0%
2.1 - Operational Waste - Food & Garden Waste 0%
2.2 - Operational Waste - Convenience of Recycling 100%
10%
1.1 Communal Spaces 92%
2.1 Vegetation 0%
2.2 Green Roofs 0%
2.3 Green Walls and Facades 0%
2.4 Private Open Space - Balcony / Courtyard Ecology 0%
3.1 Food Production - Residential 0%
3.2 Food Production - Non-Residential 0%
0%
1.1 Innovation N/A Disabled
Please enter at least one innovation.
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 6 of 22
Credit breakdown
Management Overall contribution 4%
1.1 Pre-Application Meeting 100%
Score Contribution This credit contributes 37.5% towards the category score. Criteria Has an ESD professional been engaged to provide sustainability advice from schematic
design to construction? AND Has the ESD professional been involved in a pre-
application meeting with Council? Question Criteria Achieved ?
Project Yes
2.2 Thermal Performance Modelling - Multi-Dwelling
Residential
100%
Score Contribution This credit contributes 23.2% towards the category score. Criteria Have preliminary NatHERS ratings been undertaken for all thermally unique dwellings? Question Criteria Achieved ?
Apartment Yes
2.3 Thermal Performance Modelling - Non-Residential 100%
Score Contribution This credit contributes 1.8% towards the category score. Criteria Has a preliminary facade assessment been undertaken in accordance with NCC2019
Section J1.5? Question Criteria Achieved ?
Shop Yes
Criteria Has preliminary modelling been undertaken in accordance with either NCC2019
Section J (Energy Efficiency), NABERS or Green Star? Question Criteria Achieved ?
Shop Yes
3.1 Metering 100%
Score Contribution This credit contributes 11.6% towards the category score. Criteria Have utility meters been provided for all individual dwellings? Question Criteria Achieved ?
Apartment Yes
3.2 Metering 100%
Score Contribution This credit contributes 0.9% towards the category score. Criteria Have utility meters been provided for all individual commercial tenants? Question Criteria Achieved ?
Shop Yes
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 7 of 22
3.3 Metering 100%
Score Contribution This credit contributes 12.5% towards the category score. Criteria Have all major common area services been separately submetered?
Question Criteria Achieved ?
Apartment Yes
Shop Yes
4.1 Building Users Guide 0%
Score Contribution This credit contributes 12.5% towards the category score. Criteria Will a building users guide be produced and issued to occupants? Question Criteria Achieved ?
Project No
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 8 of 22
Water Overall contribution 5% Minimum required 50%
Water Approach
What approach do you want to use for Water? Use the built in calculation tools
Project Water Profile Question
Do you have a reticulated third pipe or an on-site water recycling system? No
Are you installing a swimming pool? No
Are you installing a rainwater tank? Yes
Water fixtures, fittings and connections
Building All 1
Showerhead TH Unit 1 - Apt 5.02 4 Star WELS (>= 4.5 but <= 6.0)
Commercial 4 Star WELS (>= 6.0 but <= 7.5)
Bath TH Unit 1 - Apt 5.02 Medium Sized Contemporary
Bath
Commercial Scope out
Kitchen Taps All >= 6 Star WELS rating
Bathroom Taps All >= 6 Star WELS rating
Dishwashers All Scope out
WC All >= 4 Star WELS rating
Urinals All Scope out
Washing Machine Water Efficiency All Scope out
Which non-potable water source is the dwelling/space connected to? TH Unit 1 - Apt 5.02 Tank 1
Commercial -1
Non-potable water source connected to Toilets All No
Non-potable water source connected to Laundry (washing machine) All No
Non-potable water source connected to Hot Water System All No
Rainwater Tank
What is the total roof area connected to the rainwater tank? Tank 1 295 m2
Tank Size Tank 1 6,000 Litres
Irrigation area connected to tank Tank 1 30.0 m2
Is connected irrigation area a water efficient garden? Tank 1 Yes
Other external water demand connected to tank? Tank 1 -
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 9 of 22
1.1 Potable water use reduction 40%
Score Contribution This credit contributes 71.4% towards the category score. Criteria What is the reduction in total potable water use due to efficient fixtures, appliances,
rainwater use and recycled water use? To achieve points in this credit there must be
>25% potable water reduction. Output Reference
Project 4391 kL
Output Proposed (excluding rainwater and recycled water use)
Project 2956 kL
Output Proposed (including rainwater and recycled water use)
Project 2943 kL
Output % Reduction in Potable Water Consumption
Project 32 %
Output % of connected demand met by rainwater
Project 100 %
Output How often does the tank overflow?
Project Very Often
Output Opportunity for additional rainwater connection
Project 1239 kL
3.1 Water Efficient Landscaping 100%
Score Contribution This credit contributes 14.3% towards the category score. Criteria Will water efficient landscaping be installed? Question Criteria Achieved ?
Project Yes
4.1 Building Systems Water Use Reduction 100%
Score Contribution This credit contributes 14.3% towards the category score. Criteria Where applicable, have measures been taken to reduce potable water consumption by
>80% in the buildings air-conditioning chillers and when testing fire safety systems? Question Criteria Achieved ?
Project Yes
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 10 of 22
Energy Overall contribution 19% Minimum required 50%
Use the BESS Deem to Satisfy (DtS) method for Energy? Yes
Do all exposed floors and ceilings (forming part of the envelope)
demonstrate a minimum 10% improvement in required NCC2019
insulation levels (total R-value upwards and downwards)?
Yes
Does all wall and glazing demonstrate meeting the required NCC2019
facade calculator (or better than the total allowance)?
Yes
Are heating and cooling systems within one Star of the most efficient
equivalent capacity unit available, or Coefficient of Performance (CoP) &
Energy Efficiency Ratios (EER) not less than 85% of the CoP & EER of the
most efficient equivalent capacity unit available?
Yes
Are water heating systems within one star of the best available, or 85% or
better than the most efficient equivalent capacity unit?
Yes
Dwellings Energy Approach
What approach do you want to use for Energy? Use the built in calculation tools
Project Energy Profile Question
Are you installing any solar photovoltaic (PV) system(s)? Yes
Are you installing any other renewable energy system(s)? No
Gas supplied into building No gas connection
Dwelling Energy Profiles
Building All 1
Below the floor is TH Unit 1 - TH Unit
3
Ground or Carpark
Apt Unit 1.02 - Apt
5.02
Another Occupancy
Above the ceiling is TH Unit 1 - Apt 2.07 Another Occupancy
Apt 4.01 - Apt 5.02 Outside
Exposed sides TH Unit 1 - Apt 2.07 1
TH Unit 3 - Apt 4.03 2
Apt 4.01 - Apt 5.02 3
NatHERS Annual Energy Loads - Heat All 38.0 MJ/sqm
NatHERS Annual Energy Loads - Cool All 30.0 MJ/sqm
NatHERS star rating All 7.0
Type of Heating System All D Reverse cycle space
Heating System Efficiency All 4 Star
Type of Cooling System All Evaporative space
Cooling System Efficiency All 4 Stars
Type of Hot Water System All C Electric Heat Pump
Central Hot Water System All Yes
% Contribution from solar hot water system All 0 %
Clothes Line All A No drying facilities
Clothes Dryer All A No clothes dryer
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 11 of 22
Non-Residential Building Energy Profile
Heating, Cooling & Comfort Ventilation - Electricity - reference fabric and
reference services
-
Heating, Cooling & Comfort Ventilation - Electricity - proposed fabric and
reference services
-
Heating, Cooling & Comfort Ventilation - Electricity - proposed fabric and
proposed services
-
Heating - Wood - reference fabric and reference services -
Heating - Wood - proposed fabric and reference services -
Heating - Wood - proposed fabric and proposed services -
Hot Water - Electricity - Baseline -
Hot Water - Electricity - Proposed -
Lighting - Baseline -
Lighting - Proposed -
Peak Thermal Cooling Load - Baseline -
Peak Thermal Cooling Load - Proposed -
Solar Photovoltaic system
System Size (lesser of inverter and panel capacity) PV 1 10.0 kW peak
Orientation (which way is the system facing)? PV 1 North
Inclination (angle from horizontal) PV 1 10.0 Angle (degrees)
Which Building Class does this apply to? PV 1 Apartment
1.1 Thermal Performance Rating - Non-Residential 37%
Score Contribution This credit contributes 3.0% towards the category score. Criteria What is the % reduction in heating and cooling energy consumption against the
reference case (NCC 2019 Section J)? 1.2 Thermal Performance Rating - Residential 50%
Score Contribution This credit contributes 29.2% towards the category score. Criteria What is the average NatHERS rating? Output Average NATHERS Rating (Weighted)
Apartment 7.0 Stars
2.1 Greenhouse Gas Emissions 100%
Score Contribution This credit contributes 10.5% towards the category score. Criteria What is the % reduction in annual greenhouse gas emissions against the benchmark? Output Reference Building with Reference Services (BCA only)
Apartment 221,278 kg CO2
Output Proposed Building with Proposed Services (Actual Building)
Apartment 72,390 kg CO2
Output % Reduction in GHG Emissions
Apartment 67 %
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 12 of 22
Scoped Out
2.2 Peak Demand 7%
Score Contribution This credit contributes 5.2% towards the category score. Criteria What is the % reduction in instantaneous (peak-hour) demand against the benchmark? Output Peak Thermal Cooling Load - Baseline
Apartment 515 kW
Output Peak Thermal Cooling Load - Proposed
Apartment 462 kW
Output Peak Thermal Cooling Load - % Reduction
Apartment 10 %
2.3 Electricity Consumption 100%
Score Contribution This credit contributes 10.5% towards the category score. Criteria What is the % reduction in annual electricity consumption against the benchmark? Output Reference
Apartment 216,939 kWh
Output Proposed
Apartment 70,971 kWh
Output Improvement
Apartment 67 %
2.4 Gas Consumption N/A
This credit was scoped out No gas connection in use 3.1 Carpark Ventilation 100%
Score Contribution This credit contributes 10.5% towards the category score. Criteria If you have an enclosed carpark, is it: (a) fully naturally ventilated (no mechanical
ventilation system) or (b) 40 car spaces or less with Carbon Monoxide monitoring to
control the operation and speed of the ventilation fans? Question Criteria Achieved ?
Project Yes
3.2 Hot Water 100%
Score Contribution This credit contributes 5.2% towards the category score. Criteria What is the % reduction in annual energy consumption (gas and electricity) of the hot
water system against the benchmark? Output Reference
Apartment 93,342 kWh
Output Proposed
Apartment 35,861 kWh
Output Improvement
Apartment 61 %
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 13 of 22
Scoped Out
Disabled
3.4 Clothes Drying 0%
Score Contribution This credit contributes 4.9% towards the category score. Criteria What is the % reduction in annual energy consumption (gas and electricity) from a
combination of clothes lines and efficient driers against the benchmark? Output Reference
Apartment 17,112 kWh
Output Proposed
Apartment 17,112 kWh
Output Improvement
Apartment 0 %
3.6 Internal Lighting - Residential Multiple Dwellings 100%
Score Contribution This credit contributes 9.7% towards the category score. Criteria Is the maximum illumination power density (W/m2) in at least 90% of the relevant
building class at least 20% lower than required by Table J6.2a of the NCC 2019 Vol 1
(Class 2-9) and Clause 3.12.5.5 NCC 2019 Vol 2 (Class 1 & 10)?
Question Criteria Achieved ?
Apartment Yes
3.7 Internal Lighting - Non-Residential 100%
Score Contribution This credit contributes 0.8% towards the category score. Criteria Does the maximum illumination power density (W/m2) in at least 90% of the area of the
relevant building class meet the requirements in Table J6.2a of the NCC 2019 Vol 1? Question Criteria Achieved ?
Shop Yes
4.1 Combined Heat and Power (cogeneration /
trigeneration)
N/A
This credit was scoped out No cogeneration or trigeneration system in use. 4.2 Renewable Energy Systems - Solar 92%
Score Contribution This credit contributes 5.2% towards the category score. Criteria What % of the estimated energy consumption of the building class it supplies does the
solar power system provide? Output Solar Power - Energy Generation per year
Apartment 12,118 kWh
Output % of Building's Energy
Apartment 17 %
4.4 Renewable Energy Systems - Other N/A
This credit is disabled No other (non-solar PV) renewable energy is in use.
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 14 of 22
Stormwater Overall contribution 14% Minimum required 100%
Which stormwater modelling are you using? Melbourne Water STORM tool
1.1 Stormwater Treatment 100%
Score Contribution This credit contributes 100.0% towards the category score. Criteria Has best practice stormwater management been demonstrated? Question STORM score achieved
Project 100
Output Min STORM Score
Project 100
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 15 of 22
Achieved
Achieved
IEQ Overall contribution 9% Minimum required 50%
IEQ DTS
Use the BESS Deemed to Satisfy (DtS) method for IEQ? No
Dwellings IEQ Approach
What approach do you want to use for dwellings? Provide our own calculations
1.1 Daylight Access - Living Areas 0%
Score Contribution This credit contributes 22.5% towards the category score. Criteria What % of living areas achieve a daylight factor greater than 1% Question Percentage Achieved ?
Apartment 30 %
1.2 Daylight Access - Bedrooms 100%
Score Contribution This credit contributes 22.5% towards the category score. Criteria What % of bedrooms achieve a daylight factor greater than 0.5% Question Percentage Achieved ?
Apartment 100 %
1.3 Winter Sunlight 0%
Score Contribution This credit contributes 7.5% towards the category score. Criteria Do 70% of dwellings receive at least 3 hours of direct sunlight in all Living areas
between 9am and 3pm in mid-winter? Question Criteria Achieved ?
Apartment No
1.4 Daylight Access - Non-Residential 80%
Score Contribution This credit contributes 3.5% towards the category score. Criteria What % of the regular use floor areas have at least 2% daylight factor? Question Percentage Achieved?
Shop 80 %
1.5 Daylight Access - Minimal Internal Bedrooms 100%
Score Contribution This credit contributes 7.5% towards the category score. Criteria Do at least 90% of dwellings have an external window in all bedrooms? Question Criteria Achieved ?
Apartment Yes
2.1 Effective Natural Ventilation 66%
Score Contribution This credit contributes 22.5% towards the category score. Criteria What % of dwellings are effectively naturally ventilated? Question Percentage Achieved?
Apartment 61 %
2.3 Ventilation - Non-Residential 33%
Score Contribution This credit contributes 3.5% towards the category score.
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 16 of 22
Criteria What % of the regular use areas are effectively naturally ventilated? Question Percentage Achieved?
Shop 0 %
Criteria What increase in outdoor air is available to regular use areas compared to the minimum
required by AS 1668.2:2012? Question What increase in outdoor air is available to regular use areas compared to the minimum
required by AS 1668:2012?
Shop 50 %
Criteria What CO2 concentrations are the ventilation systems designed to achieve, to monitor
and to maintain? Question Value
Shop 0 ppm
3.4 Thermal comfort - Shading - Non-residential 0%
Score Contribution This credit contributes 1.7% towards the category score. Criteria What percentage of east, north and west glazing to regular use areas is effectively
shaded? Question Percentage Achieved?
Shop 0 %
3.5 Thermal Comfort - Ceiling Fans - Non-Residential 0%
Score Contribution This credit contributes 0.6% towards the category score. Criteria What percentage of regular use areas in tenancies have ceiling fans? Question Percentage Achieved?
Shop 0 %
4.1 Air Quality - Non-Residential 100%
Score Contribution This credit contributes 8.1% towards the category score. Criteria Do all paints, sealants and adhesives meet the maximum total indoor pollutant
emission limits? Question Criteria Achieved ?
Project Yes
Criteria Does all carpet meet the maximum total indoor pollutant emission limits? Question Criteria Achieved ?
Project Yes
Criteria Does all engineered wood meet the maximum total indoor pollutant emission limits? Question Criteria Achieved ?
Project Yes
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 17 of 22
Transport Overall contribution 7%
1.1 Bicycle Parking - Residential 100%
Score Contribution This credit contributes 20.8% towards the category score. Criteria How many secure bicycle spaces are there per dwelling for residents? Question Bicycle Spaces Provided ?
Apartment 34
Output Min Bicycle Spaces Required
Apartment 34
1.2 Bicycle Parking - Residential Visitor 100%
Score Contribution This credit contributes 20.8% towards the category score. Criteria How many secure bicycle spaces are there per 5 dwellings for visitors? Question Visitor Bicycle Spaces Provided ?
Apartment 8
Output Min Visitor Bicycle Spaces Required
Apartment 7
1.3 Bicycle Parking - Convenience Residential 100%
Score Contribution This credit contributes 10.4% towards the category score. Criteria Are bike parking facilities for residents located at ground level? Question Criteria Achieved ?
Apartment Yes
1.4 Bicycle Parking - Non-Residential 100%
Score Contribution This credit contributes 1.6% towards the category score. Criteria Have the planning scheme requirements for employee bicycle parking been exceeded
by at least 50% (or a minimum of 2 where there is no planning scheme requirement)? Question Criteria Achieved ?
Shop Yes
Question Bicycle Spaces Provided ?
Shop 3
1.5 Bicycle Parking - Non-Residential Visitor 100%
Score Contribution This credit contributes 0.8% towards the category score. Criteria Have the planning scheme requirements for visitor bicycle parking been exceeded by
at least 50% (or a minimum of 1 where there is no planning scheme requirement)? Question Criteria Achieved ?
Shop Yes
Question Bicycle Spaces Provided ?
Shop 3
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 18 of 22
1.6 End of Trip Facilities - Non-Residential 0%
Score Contribution This credit contributes 0.8% towards the category score. Criteria Where adequate bicycle parking has been provided. Is there also: * 1 shower for the
first 5 employee bicycle spaces plus 1 to each 10 employee bicycles spaces thereafter,
* changing facilities adjacent to showers, and * one secure locker per employee bicycle
space in the vicinity of the changing / shower facilities? Question Number of showers provided ?
Shop 0
Question Number of lockers provided ?
Shop 0
Output Min Showers Required
Shop 1
Output Min Lockers Required
Shop 3
2.1 Electric Vehicle Infrastructure 100%
Score Contribution This credit contributes 22.4% towards the category score. Criteria Are facilities provided for the charging of electric vehicles? Question Criteria Achieved ?
Project Yes
2.2 Car Share Scheme 0%
Score Contribution This credit contributes 11.2% towards the category score. Criteria Has a formal car sharing scheme been integrated into the development? Question Criteria Achieved ?
Project No
2.3 Motorbikes / Mopeds 0%
Score Contribution This credit contributes 11.2% towards the category score. Criteria Are a minimum of 5% of vehicle parking spaces designed and labelled for motorbikes
(must be at least 5 motorbike spaces)? Question Criteria Achieved ?
Project No
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 19 of 22
Waste Overall contribution 2%
1.1 - Construction Waste - Building Re-Use 0%
Score Contribution This credit contributes 33.3% towards the category score. Criteria If the development is on a site that has been previously developed, has at least 30% of
the existing building been re-used? Question Criteria Achieved ?
Project No
2.1 - Operational Waste - Food & Garden Waste 0%
Score Contribution This credit contributes 33.3% towards the category score. Criteria Are facilities provided for on-site management of food and garden waste? Question Criteria Achieved ?
Project No
2.2 - Operational Waste - Convenience of Recycling 100%
Score Contribution This credit contributes 33.3% towards the category score. Criteria Are the recycling facilities at least as convenient for occupants as facilities for general
waste? Question Criteria Achieved ?
Project Yes
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 20 of 22
Urban Ecology Overall contribution 1%
1.1 Communal Spaces 92%
Score Contribution This credit contributes 11.2% towards the category score. Criteria Is there at least the following amount of common space measured in square meters : *
1m² for each of the first 50 occupants * Additional 0.5m² for each occupant between 51
and 250 * Additional 0.25m² for each occupant above 251? Question Common space provided
Apartment 120 m2
Shop 0.0 m2
Output Minimum Common Space Required
Apartment 61 m2
Shop 23 m2
2.1 Vegetation 0%
Score Contribution This credit contributes 44.8% towards the category score. Criteria How much of the site is covered with vegetation, expressed as a percentage of the
total site area? Question Percentage Achieved ?
Project 4 %
2.2 Green Roofs 0%
Score Contribution This credit contributes 11.2% towards the category score. Criteria Does the development incorporate a green roof? Question Criteria Achieved ?
Project No
2.3 Green Walls and Facades 0%
Score Contribution This credit contributes 11.2% towards the category score. Criteria Does the development incorporate a green wall or green façade? Question Criteria Achieved ?
Project No
2.4 Private Open Space - Balcony / Courtyard Ecology 0%
Score Contribution This credit contributes 10.4% towards the category score. Criteria Is there a tap and floor waste on every balcony / in every courtyard? Question Criteria Achieved ?
Apartment No
3.1 Food Production - Residential 0%
Score Contribution This credit contributes 10.4% towards the category score. Criteria What area of space per resident is dedicated to food production? Question Food Production Area
Apartment 0.0 m2
Output Min Food Production Area
Apartment 19 m2
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 21 of 22
Disabled
3.2 Food Production - Non-Residential 0%
Score Contribution This credit contributes 0.8% towards the category score. Criteria What area of space per occupant is dedicated to food production? Question Food Production Area
Shop 0.0 m2
Output Min Food Production Area
Shop 6 m2
Innovation Overall contribution 0%
1.1 Innovation N/A
This credit is disabled Please enter at least one innovation.
Disclaimer
The Built Environment Sustainability Scorecard (BESS) has been provided for the purpose of information and communication. While we make every effort
to ensure that material is accurate and up to date (except where denoted as ‘archival’), this material does in no way constitute the provision of professional
or specific advice. You should seek appropriate, independent, professional advice before acting on any of the areas covered by BESS.
The Municipal Association of Victoria (MAV) and CASBE (Council Alliance for a Sustainable Built Environment) member councils do not guarantee, and
accept no legal liability whatsoever arising from or connected to, the accuracy, reliability, currency or completeness of BESS, any material contained on
this website or any linked sites
BESS, 1-3 Otter St Collingwood 3066
The Built Environment Sustainability Scorecard is an initiative of the Council Alliance for a Sustainable Built Environment (CASBE). For more details see www.bess.net.au Page 22 of 22
LCE21182 20
APPENDIX B – PRELIMINARY NATHERS ASSESSMENT
LCE21182-006 Page 1 of 5
MEMORANDUM
To: Milieu Property Date: 07 Jul 2021
Attention: Shakira Everett Reference: LCE21182-006
From: Ankita Gurav
Project: 1-3 Otter Street, Collingwood
Subject: Preliminary NatHERS Modelling Report
We provide the following preliminary Nationwide House Energy Rating Scheme (NatHERS) assessment for
the proposed residential development located at 1-3 Otter Street, Collingwood, VIC for the purposes of
town planning.
Energy ratings for the townhouses and apartments have been calculated using FirstRate5 computer
software - version V5.3.1 - formally approved as a House Energy Rating Software under the Nationwide
House Energy Rating Scheme (NatHERS) - Software Accreditation Protocol, June 2012.
Based on the architectural documentation and input data presented in this report, the preliminary ratings
have been calculated for the following 5 units which are deemed to represent a sufficient sample of
dwellings. These are displayed in Figure 1.
The modelling is based on Architectural drawings received 07th July 2021.
Figure 1 Apartments Modelled.
06
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY NATHERS ASSESSMENT
LCE21182-006 Page 2 of 5
The key input data used in the model and construction specification recommendations are given in the
following table:
Building Element Construction Details
General
Exhaust Fans/
Rangehood
Sealed to outside air with self-closing damper in the following room types:-
▪ Kitchen
▪ Bathroom/Ensuite
▪ Laundry cupboard/room
Ceiling penetrations for exhaust ductwork with loss of ceiling insulation due to
exhaust ductwork:-
150 x 150 penetration maximum
Downlights Insulation to ceiling/roof slabs to be installed above the downlights. Downlights to
be IC-Rated (Insulation Contact) where required. No loss of insulation due to
downlights.
Common Areas Assumed all class 2 common area (foyers, stairwells) are non-conditioned spaces
External Shading As per architectural drawings
Door Construction
Apartment Entrance
Doors
Weather stripped (as per part J3.4)
Glazing
Windows and Glazed
Doors
Weather-Stripped (as per part J3.4)
Window widths and heights have been modelled as per the Architectural drawings
in this assessment.
Podium/Mezzanine
Levels Apartments
High Performance double-glazed – Low E (Clear) in Aluminium frame
Awning/ Casement/ Double hung window system
Total window system properties:-
▪ U ≤ 3.4 W/(m2.K)
▪ SHGC = 0.42
Fixed window system
Total window system properties:-
▪ U ≤ 3.0 W/(m2.K)
▪ SHGC = 0.53
Sliding door system
Total window system properties:-
▪ U ≤ 2.5 W/(m2.K)
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY NATHERS ASSESSMENT
LCE21182-006 Page 3 of 5
▪ SHGC = 0.5
Tower Level
Apartments
High Performance double-glazed – Low E (Grey) in Aluminium frame
Awning/ Casement/ Double hung window system
Total window system properties:-
▪ U ≤ 3.4 W/(m2.K)
▪ SHGC = 0.15
Fixed window system
Total window system properties:-
▪ U ≤ 3.0 W/(m2.K)
▪ SHGC = 0.18
Sliding door system
Total window system properties:-
▪ U ≤ 2.5 W/(m2.K)
▪ SHGC = 0.17
Floor
Suspended slab
above unconditioned
enclosed areas below
(Carpark,
unconditioned
corridors etc.)
Suspended concrete slab with R2.0 insulation fixed hard to the underside of the
ceiling slab.
Intermediate levels
(i.e. inter-dwelling
floors)
No minimum thermal performance requirements.
Floor Coverings ▪ Floating Timber: Kitchens and Living
▪ Tiles: Bathrooms, Ensuites and Laundries
▪ Carpet: Bedrooms and Circulation.
Roof
Flat roof Suspended concrete slab with R3.5 insulation fixed hard to the underside of the
ceiling slab.
Intermediate levels,
where exposed
above (i.e. Balconies,
Unconditioned Areas
etc.)
Suspended concrete slab with R2.0 insulation fixed hard to the underside of the
ceiling slab.
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY NATHERS ASSESSMENT
LCE21182-006 Page 4 of 5
Wall
External Envelope
Walls – Typical
Precast concrete walls with min 30mm unventilated cavity to R2.5 90mm insulation
batts with plasterboard lining internally.
Spandrel with R2.5 90mm insulation batts with plasterboard lining internally.
▪ Note: Insulation is not to be compressed to fit within a cavity/space.
Internal Envelope
Walls – Typical
(between
conditioned &
unconditioned
spaces)
Plasterboard stud wall with R2.5 90mm insulation batts
▪ Note: Insulation is not to be compressed to fit within a cavity/space.
Apartment Partition
Walls (party walls
between dwellings)
Insulation in accordance with acoustic requirements. No thermal requirements.
Internal Non-
Envelope Walls
(internal dwelling
walls)
Insulation in accordance with acoustic requirements. No thermal requirements.
Based on the architectural documentation and input data indicated above, the preliminary ratings have
been calculated and are presented in the following table:-
Unit No.
Conditioned
Area
(m2)
Heating
Load
(MJ/m2)
Cooling
Load
(MJ/m2)
Total
Energy
(MJ/m2)
Star
Rating
Apt 3.01 78.5 53.3 12.2 65.5 7.6
Apt 3.04 82.7 40.8 11.4 52.2 8.1
Apt 4.02 102.3 49.8 13 62.8 7.7
Apt 6.01 131.6 84.2 17.0 101.2 6.4
Apt 6.02 137.7 87.4 18.1 105.5 6.3
Based on the above assumptions and preliminary NatHERS modelling of this sample of dwellings, we note
the following:
• The development will target to achieve an average star rating of 7.0 Stars, exceeding minimum
NCC 2019 requirements with no individual dwelling achieving less than 6.0 Star NatHERS rating.
• The development will demonstrate compliance with the Better Apartment Design Standards
(BADS) for maximum cooling energy of 30MJ/m2.
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY NATHERS ASSESSMENT
LCE21182-006 Page 5 of 5
Please note that the information outlined in this document is for the purposes of town planning only. It
cannot be used for the purposes of tender, procurement of elements as related to the thermal envelope
or obtaining building permit.
Should you have any queries regarding the above, please do not hesitate to contact the undersigned.
Yours faithfully,
LUCID CONSULTING AUSTRALIA
ANKITA GURAV
Sustainability and Energy Services Consultant
LCE21182 21
APPENDIX C – DAYLIGHT MODELLING
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
10475 – 002
MEMORANDUM
To: Milieu Property Date: 07 July 2021
Attention: Shakira Everett Reference: LCE21182-005
From: Ankita Gurav
Project: 1-3 Otter Street, Collingwood
Subject: Preliminary Daylighting Assessment Rev 01
This memorandum has been prepared to demonstrate daylight modelling of habitable rooms within the
proposed mixed-use development at 1-3 Otter Street, Collingwood, for the purposes of town planning.
The modelling presented in this memorandum is for the purpose of demonstrating performance to BESS IEQ
Credit 1.1 ‘Daylight Access – Living Areas’, Credit 1.2 ‘Daylight Access – Bedrooms’, Credit 1.4 ‘Daylight Access –
Non-Residential Areas’.
INTRODUCTION AND BASIS
This preliminary assessment is based on the following:
- Architectural drawings by Hassell, received on 07th July 2021, and
- Glass only data by Hassell, received on 8th June 2021.
Daylight modelling has been conducted on units TH03, Level 3 and Level 4 apartments and Commercial spaces
on Ground level, as indicated in Figure 1.
Figure 1 - Townhouse, Apartments and Commercial Tenancy Modelled
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY DAYLIGHT ANALYSIS
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
21182 2
These dwellings and tenancies represent the typical layouts and types within the development. These spaces
have been selected for daylight analysis as they are deemed to conservatively represent the daylight
performance of the development.
All proposed shading elements as well as the neighbouring buildings have been modelled to an accuracy
deemed acceptable for the purposes of this analysis.
BESS DAYLIGHT CRITERIA
For Apartments (Class 2) the BESS requirements for daylight are as follows:
• Credit IEQ1.1 – Daylight Access – Living Areas
80% of all living areas (including kitchens) to achieve a daylight factor greater than DF1.0% for not less
than 90% of the floor area. Additional score is awarded where 100% of living areas including kitchens
comply.
• Credit IEQ1.2 – Daylight Access – Bedrooms
80% of all bedrooms to achieve a daylight factor greater than DF0.5% for not less than 90% of the floor
area. Additional score is awarded where 100% of bedrooms comply.
For Non-Residential spaces the BESS requirements for daylight are as follows:
• Credit IEQ1.4 – Daylight Access – Non-Residential
30% of the nominated area achieves a daylight factor of at least 2%. Additional points are awarded
where it is shown that >60% or >90% of the floor area achieves this daylight factor.
Please refer to the extract of the BESS portal below.
Figure 2 - BESS Daylight Credits
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY DAYLIGHT ANALYSIS
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
21182 3
MODELLING INPUTS
Simulation and analysis have been conducted using Integrated Environmental Solution (IES) Virtual Environment
2020 software. All local shading has been incorporated into the model per the current architectural scheme.
Neighbouring buildings and adjacent dwellings have been modelled to account for their impact on daylight
modelling.
The following simulation parameters have been applied to the daylight model, consistent with standard industry
practice, generally in accordance with Green Star Design & As-Built v1.3:
▪ CIE Uniform (overcast) Sky (horizontal illuminance of 10,000 lux)
▪ Surface reflectance values:
o Floors: 30%
o Ceilings: 80%
o Internal walls: 70%
▪ Visible Light Transmittance (VLT)
o External Glazing (Podium Levels): 55%.
o External Glazing (Tower Levels): 18%
o Internal Glazing (assumed to ) : 65%
Please refer to the following figures illustrating the daylight model.
Figure 3 - Daylight Model Geometry – North East View
Balcony Spaces
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY DAYLIGHT ANALYSIS
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
21182 4
Figure 3 - Daylight Model Geometry – North West (Left) View South West (Right) View
RESULTS AND DISCUSSION
Please find the daylighting results presented for all the assessed areas in Table 1 below.
Table 1: Daylight Results Summary
Habitable Room Ave. Daylight
Factor % Floor Area %
Compliant Min. %
DF Max. %
DF
Non-residential spaces DF Threshold 2.0%
Ground floor Commercial Space 5.2 80 1.1 18.4
Living spaces (including Kitchen) DF Threshold 1.0%
TH03 Living/ Kitchen Space 3.7 100 1.0 18.1
3.01 Living/ Kitchen Space 3.1 75.0 0.5 14.1
3.02 Living/ Kitchen Space 3.4 78.5 0.6 18.6
3.03 Living/ Kitchen Space 3.2 70.6 0.4 18.3
3.04 Living/ Kitchen Space 1.1 33.1 0.1 17.1
3.05 Living/ Kitchen Space 1.8 45.9 0.2 16.3
3.06 Living/ Kitchen Space 1.5 34.2 0.0 12.2
4.01 Living/ Kitchen Space 3.7 100 1.4 8.4
4.02 Living/ Kitchen Space 2.3 93.8 0.6 5.3
4.03 Living/ Kitchen Space 2.4 71.2 0.3 7.8
Bedroom spaces DF Threshold 0.5%
TH03 Bed 1 5.9 100.0 1.8 18.4
TH03 Bed 2 6.4 100.0 2.8 12.2
3.01 Bed 1 5.4 100.0 2.2 17.7
3.01 Bed 2 2.4 100.0 0.4 12.1
3.02 Bed 1 3.6 100.0 1.3 8.1
3.02 Bed 2 3.6 100.0 0.6 17.7
3.03 Bed 1 2.6 100.0 1.6 4.4
3.03 Bed 2 4.8 100.0 1.4 16.8
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY DAYLIGHT ANALYSIS
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
21182 5
3.04 Bed 1 5.6 100.0 1.8 18.9
3.04 Bed 2 4.0 100.0 1.7 7.7
3.05 Bed 1 4.2 100.0 1.8 10.0
3.05 Bed 2 2.4 99.3 0.4 12.4
3.06 Bed 1 3.0 100.0 0.6 12.3
4.01 Bed 1 4.0 100.0 1.9 7.5
4.01 Bed 2 1.9 100.0 0.8 5.0
4.01 Bed 3 1.3 99.2 0.5 3.9
4.02 Bed 1 1.8 100.0 0.6 5.0
4.02 Bed 2 1.9 100.0 0.6 5.0
4.02 Bed 3 5.0 100.0 2.5 8.2
4.03 Bed 1 1.4 100.0 0.6 4.0
4.03 Bed 2 1.4 99.3 0.4 4.0
4.03 Bed 3 1.4 99.6 0.5 4.0
Total percentage of number of Living spaces (including kitchen) achieving DF greater than 1% for at least 90%
floor area 30%
Total percentage of number of Bedroom spaces achieving DF greater than 0.5% for at least 90% floor
area 100%
Please refer Appendix A for contour plots of the daylight factor for all spaces modelled.
This analysis has demonstrated that on the basis of the sample of dwellings modelled, 100% of bedrooms meet
the required BESS daylight criteria (90% of floor area with DF0.5%) and 30% of living areas (including kitchens)
achieve the required BESS daylight criteria (90% of floor area with DF1.0%).
The development achieves compliance with IEQ Credit 1.2, Daylight Access – Bedrooms and IEQ Credit 1.4
Daylight Access- Non-Residential but no points are attained for Credit 1.1 Daylight Access – Living Areas.
We note that the daylight metrics used within BESS are such that it is a highly common outcome that bedroom
spaces will achieve a high level of compliance (primarily associated with glazing are to floor area) whereas living
areas (including kitchens) are generally problematic due to depth from façade and the % floor area compliance
metric used for assessment.
In our professional opinon, we hold no concerns regarding the daylight performance presented within this
development.
Should you have any queries regarding the above, please do not hesitate to contact the undersigned.
Yours faithfully,
LUCID CONSULTING AUSTRALIA
ANKITA GURAV
Sustainability and Energy Services Consultant
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY DAYLIGHT ANALYSIS
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
21182 6
APPENDIX A
Figure A1 - Daylight Factor Contour Plot and Contour Threshold: Commercial Tenancy
Figure A2 - Daylight Factor Contour Plot and Contour Threshold: TH03 Living (incl Kitchens)
Figure A3 - Daylight Factor Contour Plot and Contour Threshold: TH03 Bedroom Spaces
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY DAYLIGHT ANALYSIS
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
21182 7
Figure A4 - Daylight Factor Contour Plot: Level 3 Living Spaces (incl. Kitchens)
Figure A5 - Daylight Factor Contour Threshold: Level 3 Living Spaces (incl. Kitchens)
Figure A6 - Daylight Factor Contour Plot: Level 3 Bedroom Spaces
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY DAYLIGHT ANALYSIS
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
21182 8
Figure A7 - Daylight Factor Contour Threshold: Level 3 Bedroom Spaces
Figure A8 - Daylight Factor Contour Plot: Level 4 Living Spaces (incl. Kitchens)
Figure A9 - Daylight Factor Contour Threshold: Level 4 Living Spaces (incl. Kitchens)
1-3 OTTER STREET, COLLINGWOOD
PRELIMINARY DAYLIGHT ANALYSIS
Level 1, 5 Queens Road, Melbourne VIC 3004 P: 03 9867 8770
21182 9
Figure A10 - Daylight Factor Contour Plot: Level 4 Bedroom Spaces
Figure A11 - Daylight Factor Contour Threshold: Level 4 Bedroom Spaces