3
This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date entered in the `Approved'-field. A manual signature is not required. Drawing sheet ISO 5457-A4T rev A We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved. D C B E F 1 2 3 4 C C 205 C 27 D 470 A 200 600 710 740 24x n 15 B 1097 111 126 100 332 30 255 255 98 6 45 4x 14 255 C/L Top flange 80 C/L Diverter switch 30 460 730 821 671 60 200 200 723 43 223 373 435 () 373 100 100 381 381 552 INSULATION380 1050 SHORT VERSION b) LEVEL kV 650 380,650 750 750 1050 A2451 a)2451 a)2231 a)2531 a) Dimen- sions in mm B1354 a)1654 a)1134 a)1434 a) C 119 a)c) 119 a) 119 a)c) 119 a) D 240 c) 540 240 c) 540 1/3 EN F 1ZSC004528-ACA Sheet Language Revision Document Id. UCGR, UCGD B(2ph) XXXX/300-600/F 10-11,14-35 Pos TAP-CHANGER Title DIMENSION DRAWING PGCO/TK 2017-10-27 Document Kind Responsible department Date / Approved Diverter switch terminal, no 30. 1) Shielding rings for insulating levels 650, 750 and 1050 kV only. 2) Only for positions 14-35 3) Only for positions 10-11 4) Shielding ring for insulating levels 650, 750 and 1050 kV only. Shielding ring diameter additional 6 for insulating level 1050 kV only. a) For mounting on active part use A+106,B+10 and C+106 (See also Drawing 54920103-1) b) Short version means reduced switching capa Please refer to Technical Guide c) Not applicable for 380 kV 1 1 1 Transformer flange C/L Tap selector H 2..18. 21 22 22 21 V 1..17. V 1..17. H 2..18. 4 C-C 3 2

1 2 3 4 UCGD B(2ph) XXXX/300-600/F 10-11,14-35 Pos TAP-CHANGER Title 2017-10-27 PGCO/TK DIMENSION DRAWING Date / Approved Responsible department Document Kind Diverter switch terminal,

  • Upload
    lythuan

  • View
    213

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1 2 3 4 UCGD B(2ph) XXXX/300-600/F 10-11,14-35 Pos TAP-CHANGER Title 2017-10-27 PGCO/TK DIMENSION DRAWING Date / Approved Responsible department Document Kind Diverter switch terminal,

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

Drawing sheet ISO 5457-A4T rev A

We reserve all rights in this document and in the information contained

therein. Reproduction, use or disclosure to third parties without express

authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.

D

C

B

E

F

1 2 3 4

C

C

205

C

27

D 470

A

200

600

710

740

24x �n�

15

B1097

111

126

100

332

30

255 255

98

6 45

4x 14

255

C/L Top flange80

C/L Diverter switch30

460 730

821

671

60

200

200

723

43

223 373

435

()

373

100

100

381381

552

INSULATION380 1050 SHORT VERSION b)LEVEL kV 650 380,650

750 750 1050A 2451 a)2451 a)2231 a)2531 a)Dimen-

sionsin mm

B 1354 a)1654 a)1134 a)1434 a)C 119 a)c)119 a) 119 a)c)119 a)D 240 c) 540 240 c) 540

1/3ENF1ZSC004528-ACA

SheetLanguageRevisionDocument Id.

UCGR, UCGD B(2ph) XXXX/300-600/F 10-11,14-35 Pos

TAP-CHANGER

Title

DIMENSION DRAWING PGCO/TK2017-10-27

Document KindResponsible departmentDate / Approved

Diverter switch terminal, no 30.

1) Shielding rings for insulating levels 650, 750 and 1050 kV only.2) Only for positions 14-353) Only for positions 10-114) Shielding ring for insulating levels 650, 750 and 1050 kV only. Shielding ring diameter additional 6 mm for insulating level 1050 kV only.

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)b) Short version means reduced switching capacity. Please refer to Technical Guidec) Not applicable for 380 kV

1

1

1

Transformer flange

C/L Tap selector

H 2..18.

21

22

22

21

V 1..17.

V 1..17.

H 2..18.

4

C-C

32

Page 2: 1 2 3 4 UCGD B(2ph) XXXX/300-600/F 10-11,14-35 Pos TAP-CHANGER Title 2017-10-27 PGCO/TK DIMENSION DRAWING Date / Approved Responsible department Document Kind Diverter switch terminal,

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

Drawing sheet ISO 5457-A4T rev A

We reserve all rights in this document and in the information contained

therein. Reproduction, use or disclosure to third parties without express

authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.

D

C

B

E

F

1 2 3 4

70�$�

30�$�

40�$�

36�$�

36�$�

36�$�

36�$�

72�$�

36�$�36�$�

260 415

40�$�70�$�

36�$�

18�$�

18�$�36�$�

36�$�

36�$�

36�$�

36�$�54�$�

25

48

44

13

651

60

165

85 140 250

25

90

490

95

1081

340 12x 18

920

135

189

95135

165

60

30�$�

55

27,5

46

17,5

R315

13

2/3ENF1ZSC004528-ACA

SheetLanguageRevisionDocument Id.

UCGR, UCGD B(2ph) XXXX/300-600/F 10-11,14-35 Pos

TAP-CHANGER

Title

DIMENSION DRAWING PGCO/TK2017-10-27

Document KindResponsible departmentDate / Approved

D - D

10-11 POSITIONS

1/2

3/4

5/6

7/8

9/1011

20

21

22

A - A

V

H R297

R297

Current Collection

14-15 POSITIONS

1/2

3/45/6

7/8

9/10

11/1213/14

15

20

21

22

A - AV

H

D

D

T=15

T=26

Page 3: 1 2 3 4 UCGD B(2ph) XXXX/300-600/F 10-11,14-35 Pos TAP-CHANGER Title 2017-10-27 PGCO/TK DIMENSION DRAWING Date / Approved Responsible department Document Kind Diverter switch terminal,

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

Drawing sheet ISO 5457-A4T rev A

We reserve all rights in this document and in the information contained

therein. Reproduction, use or disclosure to third parties without express

authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.

D

C

B

E

F

1 2 3 4

70�$�

30�$�

40�$�

72�$�

54�$�

18�$�

72�$�

18�$�54�

$�

70�$�

30�$�

40�$�

72�$�

54�$�

18�$�

36�$�

36�$� 18�$�54�

$�

40�$�

30�$�

70�$�

36�$�

18�$�18�$�

72�$�

18�$� 18�$�

36�$� 72�$� 40�$�

30�$�

70�$�

36�$�

18�$�18�$�

36�$�

36�$�

18�$� 18�$�

36�$� 72�$�

68,5�$�

28,5�$�

41,5�$�

54�$�

36�$�

36�$�

18�$�

9�$�

36�$�

36�$� 18�$�18�$�

36�$�

9�$�

260 415

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide UCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL2:1ZSC004106-AAEMotor Drive BUE:1ZSC004106-AAH or -AAJExternal Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1Holes for mounting of supportfor cleats and leads: 1ZSC026099

3/3ENF1ZSC004528-ACA

SheetLanguageRevisionDocument Id.

UCGR, UCGD B(2ph) XXXX/300-600/F 10-11,14-35 Pos

TAP-CHANGER

Title

DIMENSION DRAWING PGCO/TK2017-10-27

Document KindResponsible departmentDate / Approved

R297

R297

1/2

3/4

5/6

7/8

9/1021

22

20

16-19 POSITIONS

A - A

V

H

Current Collector

21

22

20

1/2

3/4

5/6

7/8

9/10

11/12

20-23 POSITIONS

A - A

V

H

21

22

20

1/2

3/45/6

7/8

9/10

11/12

13/14

24-27 POSITIONS

A - AV

H

21

22

20

1/2

3/45/6

7/8

9/10

11/12

13/14

15/16

28-31 POSITIONS

A - AV

H

21

22

20

1/2

3/45/6

7/8

9/10

11/12

13/1415/16

17/18

32-35 POSITIONS

A - A