26
Typical Panel Fixing Arrangement Drwg. No.: Client: Project: Title: Rev Details Drawn by: Date: Scale: All Saints Industrial Estate Shildon County Durham DL4 2RD Tel: Fax: Email: www.pspuk.com 00 44 (0) 1388 770490 00 44 (0) 1388 778068 [email protected] Unit 11 Status: Revision: Date Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the specification compliance for each project, PSP will not be held responsible for any project non conformities. DO NOT SCALE IF IN DOUBT - ASK PSP SYSTEM - Matrix IPH Matrix IPH Standard Details P.S.P. PSP-MIPH-A01 sns 20.3.17 1:2 @ A3 Approved - 600 MAX. 1800 MAXIMUM LENGTH WITH DIRECT FIXINGS EXPANSION EXPANSION 600 MAX. 600 MAX. 600 MAX. GRAIN ISOMETRIC VIEW OF TYPICAL PANEL FIXING ARRANGEMENT PANELS UNDER 1800 LG FIXED DIRECTLY TO VERTICAL CARRIERS. PANELS OVER 1800 LG FIXED DIRECTLY IN CENTRAL AREA & WITH FIXING CLIPS @ PANEL ENDS. (HORIZONTALLY LAID) OPTIONAL END RETURN OMITTED FOR CLARITY 3 1 24 7 24 JOINTS SIZE - PROJECT SPECIFIC; STANDARD Matrix IPH JOINTS ARE 5mm, 10mm, 15mm & 20mm ITEM 24: STAINLESS STEEL FIXING CLIP Optional colour matched cover trim Stainless steel fixing (TBC) 8 Insulation by others Cement particle board by others Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max 5 6 4 1 2 3 PARTS LIST 7 9 10 11 Internal boards by others 12 Breather membrane by others 13 Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm 14 15 Additional rigid sheet insulation if required by others 16 JT4-4-4.8x19 Stainless steel fixing JT4-6-5.5x22 A14 Stainless steel fixing Optional PVC thermal break, 5mm 17 SFS support structure by others 18 19 20 21 22 'Top hat' profile (optional) Aluminium flashing (Jamb/Head/Coping/Drip) 23 Fire / Smoke Barrier and fittings by others 24 EPDM by others 25 26 Weather seal by others 27 Aluminium carrier bracket, 3mm thick Internal / External corner flashing Stainless Steel Fixing Clip Support Angle Adjacent Window / Door Profile Fixing bracket Corner support angle (factory assembled) Optional Ventilation profile / insect mesh Removable panel (replacement procedure ref to PSP-MIPH-S10)

1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

Typical Panel Fixing

Arrangement

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-A01

sns20.3.17

1:2 @ A3

Approved

-

6

0

0

M

A

X

.

1

8

0

0

M

A

X

I

M

U

M

L

E

N

G

T

H

W

I

T

H

D

I

R

E

C

T

F

I

X

I

N

G

S

E

X

P

A

N

S

I

O

N

E

X

P

A

N

S

I

O

N

6

0

0

M

A

X

.

6

0

0

M

A

X

.

6

0

0

M

A

X

.

G

R

A

I

N

ISOMETRIC VIEW OF TYPICAL

PANEL FIXING ARRANGEMENT

P

A

N

E

L

S

U

N

D

E

R

1

8

0

0

L

G

F

I

X

E

D

D

I

R

E

C

T

L

Y

T

O

V

E

R

T

I

C

A

L

C

A

R

R

I

E

R

S

.

P

A

N

E

L

S

O

V

E

R

1

8

0

0

L

G

F

I

X

E

D

D

I

R

E

C

T

L

Y

I

N

C

E

N

T

R

A

L

A

R

E

A

&

W

I

T

H

F

I

X

I

N

G

C

L

I

P

S

@

P

A

N

E

L

E

N

D

S

.

(HORIZONTALLY LAID)

OP

TIO

NA

L E

ND

R

ET

UR

N

OM

IT

TE

D F

OR

C

LA

RIT

Y

3

1

24

7

24

JOINTS SIZE - PROJECT SPECIFIC;

STANDARD Matrix IPH JOINTS

ARE 5mm, 10mm, 15mm & 20mm

ITEM 24: STAINLESS STEEL FIXING CLIP

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

Page 2: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-A02

sns20.3.17

1:2 @ A3

Approved

-

Typical Panel Section

LAY

51

OVERALL PANEL FACE SIZE

'Y'

'X' VARIES TO

SUIT JOINT WIDTH

LINE OF END RETURN (OPTIONAL

STANDARD 'X' & 'Y' DIMENSIONS

JOINT WIDTH DIM 'X' DIM 'Y' MIN. DIM 'Y' MAX.

5mm 15mm 185mm 685mm

10mm 20mm 180mm 680mm

15mm 25mm 175mm 675mm

20mm 30mm 170mm 670mm

(DATUM EDGE)

(If Stainless Steel Fixing Clip to be used)

TYPICAL PANEL SECTION

ROLLFORM PLANK

1

57

(Standard Joint)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

JOINTS SIZE - PROJECT SPECIFIC;

STANDARD Matrix IPH JOINTS

ARE 5mm, 10mm, 15mm & 20mm

Page 3: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

Typical Double Female Panel

Section

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-A03

sns20.3.17

1:2 @ A3

Approved

-

JOINTS SIZE - PROJECT SPECIFIC;

STANDARD Matrix IPH JOINTS

ARE 5mm, 10mm, 15mm & 20mm

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

51

OVERALL PANEL FACE SIZE

LINE OF END RETURN (OPTIONAL)

51

1

TYPICAL DOUBLE FEMALE PANEL SECTION

ROLLFORM PLANK

(If Stainless Steel Fixing Clip to be used)

57

(Standard Joint)

(If Stainless Steel Fixing Clip to be used)

57

(Standard Joint)

Page 4: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

Typical Double Male Panel Section

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-A04

sns20.3.17

1:2 @ A3

Approved

-

JOINTS SIZE - PROJECT SPECIFIC;

STANDARD Matrix IPH JOINTS

ARE 5mm, 10mm, 15mm & 20mm

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

TYPICAL DOUBLE MALE PANEL SECTION

ROLLFORM PLANK

OVERALL PANEL FACE SIZE

VARIES TO

SUIT JOINT WIDTH

LINE OF END RETURN (OPTIONAL)

1

Page 5: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

TYPICAL BRACKET ARRANGEMENT

Fixed point

bracket

Sliding point

bracket

Sliding point

bracket

Sliding point

bracket

Fixed point

bracket

Sliding point

bracket

FIXED POINT BRACKET

SLIDING POINT BRACKET

absorb wind loading and allow for expansion and contraction

absorb both vertical dead loads

min 10m

m

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-A05

sns 20.3.17 1:2 @ A3

Approved

-

Fixed & Sliding Brackets

Points Setting Out

Page 6: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-P01

sns9.3.17

1:2 @ A3

Approved

-

Vertical Panel Joint Detail

(Plan View - under 1800mm)

de

f

VERTICAL PANEL JOINT DETAIL

9 10 12 11

1 2

5 13

cb

module length module length

3 4 76

14

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

8

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

a

20mm nominal

24

20

Optional end folds

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

Page 7: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

de

fc

b

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

P.S.P.

sns 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

VERTICAL PANEL JOINT DETAIL

(over 1800mm)

ITEM 24: STAINLESS STEEL FIXING CLIP

a

20mm nominal

24

9 10 12 115 13 14

8

1 23 4 76

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

24

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

PSP-MIPH-P02

9.3.17

Vertical Panel Joint Detail

(Plan View - over 1800mm)

Page 8: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

de

fc

b

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

P.S.P.

sns 1:2 @ A3

Approved

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

a

24

9 10 12 115 13 14

8

1 23 76

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

9.3.17

Vertical Midspan Support Detail

PSP-MIPH-P03

Page 9: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

EXTERNAL CORNER PANEL DETAIL

20m

m nom

inal

1

3

4

7

6

8 11 9 10 13

12

14

d e fcb

2

5

Maximum corner

length to suit

material availability

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-P04

sns 10.3.17 1:2 @ A3

Approved

-

External Corner Panel Detail

(Plan View)

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

20mm nominal

a

additional bracket required

if larger 400mm

24

FA

CT

OR

Y M

IT

RE

D C

OR

NE

R

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

18

18

Page 10: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

20m

m nom

inal

23

EXTERNAL CORNER FLASHING DETAIL

Maximum corner

length to suit

material availability

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-P05

sns 10.3.17 1:2 @ A3

Approved

-

External Corner Flashing Detail

(Plan View)

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

20mm nominal

24

20mm nominal

additional bracket required

if larger 400mm

24

8 2

1

3

7

6

12

14

5

11 9 10 13

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

18

18

Page 11: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

def c b a

9

12

5

10

11

13

14

1

3

7

2

3

8

6

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-P06

sns 10.3.17 1:2 @ A3

Approved

-

Internal Corner Detail

(Plan View)

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

INTERNAL CORNER DETAIL

20m

m m

in

23

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

18

18

Page 12: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

BRICKWORK ABUTMENT DETAIL

c

9 101211 5

20mm min

137

8 13

6

2

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-P07

sns 10.3.17 1:2 @ A3

Approved

-

Brickwork Abutment Detail

(Plan View)

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

4

ad

ef

cb

a

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

Page 13: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

WINDOW JAMB DETAIL

9 1011 5

17

21

19

1

module length

2 3 7

6

de

fc

b

14

813

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-P08

sns 10.3.17 1:2 @ A3

Approved

-

Window Jamb Detail

(Plan View)

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

22

10

a

20

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

18

Page 14: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

DOOR JAMB DETAIL

module length

de

fc

b

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-P09

sns 14.3.17 1:2 @ A3

Approved

-

Door Jamb Detail

(Plan View)

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

10

a

20

1 2 3 714

9 1011 5

19

813

22

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

17

21

6

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

18

Page 15: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

module length

de

fc

b

CURTAIN WALL JAMB DETAIL

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-P10

sns 15.3.17 1:2 @ A3

Approved

-

Curtain Walling Jamb Detail

(Plan View)

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

1510

a

1 2 3 714

9 1011 5

19

813

22

17

6

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

20

23

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

18

Page 16: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

Horizontal Panel Joint Detail

(Sectional View)

HORIZONTAL PANEL JOINT DETAIL

5

2

24

d e fcba

3

14

7

9

10

11

13

12

1

6

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S01

sns 15.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

8

20

module height

20

module height

PVC temporary set out packer

to be sued to set joints

20

panel face

module height

20

PVC temporary set out packer

to be sued to set joints

Fixing position if

over 1800mm

Fixing position if

under 1800mm

LAY

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

57,4

51

15

Page 17: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

BASE DRIP DETAIL

d e fcb

6

2

Base Drip Detail

(Sectional View)

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S02

sns 15.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

20

1

a

3

7

24

Fixing position if

over 1800mm

LAY

17

26

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

5

2

14

9

10

11

13

12

8

module height

20

panel face

module height

40

51

Page 18: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

COPING FLASHING DETAIL

5

1

7

10

11

13

12

d ecb

2

14

6

17

16

Coping Flashing Detail

(Sectional View)

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S03

sns 15.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

8

Fixings to secure coping to be determined

on an individual project basis.

3

a

Fixing position if

over 1800mm

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

Page 19: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

WINDOW HEAD DETAIL

dcb e f

17 21

19

8

5

1

3

10

11

14

Drainage slots

6

2

13

7

22

Window Head Detail

(Sectional View)

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S04

sns 16.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

a

Drainage slots

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

LAY

25

51

18

Page 20: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

WINDOW CILL DETAIL

19

8

5

1

3

10

13

9

12

d ecb

2

14

6

f

17

22

Window Base Detail 2

(Sectional View)

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S05

sns 16.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

21

10

module height

10

a

LAY

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

18

Page 21: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

DOOR HEAD DETAIL

module height

dcb e f

17 21

8

5

1

3

10

11

14

Drainage slots

6

2

13

22

Door Head Detail 1

(Sectional View)

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S06

sns 16.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

a

Drainage slots

51

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

19

18

Page 22: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

17 25

8

5

dcb

14

10

e f

Drainage slots

CURTAIN WALL HEAD DETAIL

Fixings subject to

Structural Analysis

19

5

16

4

13

22

Curtain Walling Head Detail

(Sectional View)

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S07

sns 16.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

module height

1

3

14

6

2

a

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

51

18

Page 23: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

FIRE BARRIERS DETAIL

Fire Barrier Detail

(Sectional View)

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S08

sns 16.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

12

10

9

11

18

d e fcb

13

1

14

Intumescent strip

expansion refer to

manufacturer

a

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

Page 24: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

8

5

2

2

7

d e fcba

3

9

10

11

13

12

REMOVABLE PANEL HORIZONTAL JOINT DETAIL

Replacement procedure ref to PSP-MIPH-S10

Removal Panel Joint Detail

(Sectional View)

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

PSP SYSTEM - Matrix IPH

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S09

sns 16.3.17 1:2 @ A3

Approved

-

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

14

1

module height

20

module height

20

panel face

module height

LAY

a PSP Panel thickness - 24mm

LEGEND

b

c

d

e

f

Insulation by others (must be Part B Compliant)

CP board by others - thickness established by project specification

SFS by others - depth established by project specification

Internal finishes by others

Ventilated cavity (British standard - 25mm, NHBC - 38mm (baffled joints)

and 50mm (open joints)

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

STANDARD MATRIX-IP VERTICAL &

HORIZONTAL JOINTS ARE 20mm

57,4

51

Page 25: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

Replacement Panel Procedure

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S10

sns 16.3.17 1:2 @ A3

Approved

Details

1. PANEL TO BE REMOVED TO BE CUT ALONG JOINT

2. UNSCREW/CHISEL OFF EXISTING FIXING HEAD FROM BELOW

3. INSERT NEW PANEL

4. FIX VIA JOINT USING LOW PROFILE HEADED FIXING

PROCEDURE

(THIS DRAWING SHOWS HORIZONTALLY LAID PANELS.

FOR VERTICALLY LAID PANELS ROTATE 90°)

CUT

UNSCREW/CHISEL OFF

FIXING

INSERT

NEW PANEL

FIX

STEP 1 STEP 2 STEP 3 STEP 4

PSP SYSTEM - Matrix IPH

Page 26: 1 2 3 4 EXPANSION · psp-miph-a01 sns20.3.171:2 @ a3 approved-600 max.1800 maximum length with direct fixings expansion expansion 600 max. 600 max. 600 max. grain isometric view of

MOVEMENT

SLIDING

BRACKET

FIXED

POINT

BRACKET

FLOOR SLAB

BY OTHERS

WALL

STRUCTURE

BY OTHERS

WALL

STRUCTURE

BY OTHERS

VERTICAL

T-RAIL

AS REQ

'D

LOWER PANEL

CAN BE MADE

REMOVABLE OR

RETROFITTED IF

REQUIRED

FEMALE EDGE

OF LOWER PANEL

AS STANDARD

PANEL

MOVEMENT JOINT DETAIL

Drwg. No.:

Client:

Project:

Title:

Rev Details

Drawn by:Date: Scale:

All Saints Industrial Estate

Shildon

County Durham

DL4 2RD

Tel:

Fax:

Email:

www.pspuk.com

00 44 (0) 1388 770490

00 44 (0) 1388 778068

[email protected]

Unit 11

Status:

Revision:

Date

Details are for indicative purposes only, it is the responsibility of the installer / designer to ensure the

specification compliance for each project, PSP will not be held responsible for any project non conformities.

DO NOT SCALE IF IN DOUBT - ASK

Typical Movement Joint

Details

Matrix IPH Standard Details

P.S.P.

PSP-MIPH-S11

sns 20.3.17 1:2 @ A3

Approved

module height

20

module height

20

panel face

LAY

8

1

2

3

12

25

7

6

Optional colour matched cover trim

Stainless steel fixing (TBC)

8

Insulation by others

Cement particle board by others

Panel - Zinc/Aluminium/Steel skin - 1.2mm thk max

5

6

4

1

2

3

PARTS LIST

7

9

10

11

Internal boards by others

12

Breather membrane by others

13

Aluminium carrier T-rail, 100x40mm / L-rail, 60x40mm

14

15

Additional rigid sheet insulation if required by others

16

JT4-4-4.8x19 Stainless steel fixing

JT4-6-5.5x22 A14 Stainless steel fixing

Optional PVC thermal break, 5mm

17

SFS support structure by others

18

19

20

21

22

'Top hat' profile (optional)

Aluminium flashing (Jamb/Head/Coping/Drip)

23

Fire / Smoke Barrier and fittings by others

24

EPDM by others

25

26

Weather seal by others

27

Aluminium carrier bracket, 3mm thick

Internal / External corner flashing

Stainless Steel Fixing Clip

Support Angle

Adjacent Window / Door Profile

Fixing bracket

Corner support angle (factory assembled)

Optional Ventilation profile / insect mesh

Removable panel (replacement procedure ref to PSP-MIPH-S10)

24

PSP SYSTEM - Matrix IPH

5

9

10

11

13

N

N

LEGEND:

part of system, provided by PSP

provided by others

N

not part of system, can be provided by PSP

18