3
This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date entered in the `Approved'-field. A manual signature is not required. Drawing sheet ISO 5457-A4T rev A We reserve all rights in this document and in the information contained therein. Reproduction, use or disclosure to third parties without express authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved. D C B E F 1 2 3 4 C C 255 255 98 6 470 600 30 27 255 111 205 D 126 B 43 747 A 223 200 100 373 821 740 710 460 730 12x n 15 C/L Top flange 80 671 C/L Diverter switch 30 C 332 60 45 4x 14 190 435 100 () 373 381 381 552 INSULATION380 1050 SHORT VERSION b) LEVEL kV 650 380,650 750 750 1050 A2101 a)2401 a)1881 a)2181 a) Dimen- sions in mm B1354 a)1654 a)1134 a)1434 a) C 119 a)c) 119 a) 119 a)c) 119 a) D 240 c) 540 240 c) 540 1/3 EN F 1ZSC004528-ABZ Sheet Language Revision Document Id. UCGR, UCGD E,T XXXX/300-1500/F 10-11,14-35 Pos TAP-CHANGER UCGR,UCGD B(1ph) XXXX/300-600/F 10-11,14-35 Pos and Title DIMENSION DRAWING PGCO/TK 2017-10-27 Document Kind Responsible department Date / Approved Diverter switch terminal, no 30. 1) Shielding rings for insulating levels 650, 750 and 1050 kV only. a) For mounting on active part use A+106,B+10 and C+106 (See also Drawing 54920103-1) b) Short version means reduced switching capa Please refer to Technical Guide c) Not applicable for 380 kV 2) Only for positions 14-36 3) Only for positions 10-11 4) Shielding ring for insulating levels 650, 750 and 1050 kV only. Shielding ring diameter additional 6 for insulating level 1050 kV only. V 1..17. H 2..18. 1 1 1 Transformer flange C/L Tap selector 21 22 4 C-C 3 2

1 2 3 4...4 C-C 2 3 This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date entered in

  • Upload
    others

  • View
    0

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 1 2 3 4...4 C-C 2 3 This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date entered in

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

Drawing sheet ISO 5457-A4T rev A

We reserve all rights in this document and in the information contained

therein. Reproduction, use or disclosure to third parties without express

authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.

D

C

B

E

F

1 2 3 4

C

C

255 255

98

6

470

600

30

27

255

111 205

D126

B

43

747

A

223

200

100 373

821

740

710

460 730

12x �n�

15

C/L Top flange80

671

C/L Diverter switch30

C

332

60

45

4x 14

190

435

100

()

373

381381

552

INSULATION380 1050 SHORT VERSION b)LEVEL kV 650 380,650

750 750 1050A 2101 a)2401 a)1881 a)2181 a)Dimen-

sionsin mm

B 1354 a)1654 a)1134 a)1434 a)C 119 a)c)119 a) 119 a)c)119 a)D 240 c) 540 240 c) 540

1/3ENF1ZSC004528-ABZ

SheetLanguageRevisionDocument Id.

UCGR, UCGD E,T XXXX/300-1500/F 10-11,14-35 Pos

TAP-CHANGER UCGR,UCGD B(1ph) XXXX/300-600/F 10-11,14-35 Pos and

Title

DIMENSION DRAWING PGCO/TK2017-10-27

Document KindResponsible departmentDate / Approved

Diverter switch terminal, no 30.

1) Shielding rings for insulating levels 650, 750 and 1050 kV only.

a) For mounting on active part use A+106,B+106 and C+106 (See also Drawing 54920103-1)b) Short version means reduced switching capacity. Please refer to Technical Guidec) Not applicable for 380 kV

2) Only for positions 14-363) Only for positions 10-114) Shielding ring for insulating levels 650, 750 and 1050 kV only. Shielding ring diameter additional 6 mm for insulating level 1050 kV only.

V 1..17.

H 2..18.

1

1

1

Transformer flange

C/L Tap selector

2122

4

C-C

32

Page 2: 1 2 3 4...4 C-C 2 3 This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date entered in

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

Drawing sheet ISO 5457-A4T rev A

We reserve all rights in this document and in the information contained

therein. Reproduction, use or disclosure to third parties without express

authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.

D

C

B

E

F

1 2 3 4

36�$�

36�$�

72�$�

36�$�

36�$� 36�$�36�$�

40�$�

40�$�54�$�

36�$�

36�$�

36�$�

36�$� 18�$�18�$�

36�$�

27�$�

9�$�

651

1081

340

260

140 250

165 95

135 490

12x �n�18

920

44

25

48

13

260 415

30�$�

70�$�

30�$�

70�$�

165

60

60

85

25

90 189

95135

55

46

17,5 27,5

R315

13

2/3ENF1ZSC004528-ABZ

SheetLanguageRevisionDocument Id.

UCGR, UCGD E,T XXXX/300-1500/F 10-11,14-35 Pos

TAP-CHANGER UCGR,UCGD B(1ph) XXXX/300-600/F 10-11,14-35 Pos and

Title

DIMENSION DRAWING PGCO/TK2017-10-27

Document KindResponsible departmentDate / Approved

10-11 POSITIONS

1/2

3/4

5/6

7/8

9/1011

20

21

22

A - A

V

HR297

R297

Current Collector

14-15 POSITIONS

1/2

3/45/6

7/8

9/10

11/1213/14

15

20

21

22A - A

V

H

D

B - B

D

T=15

D - D

T=26

Page 3: 1 2 3 4...4 C-C 2 3 This document is issued by means of a computerized system. The digitally stored original is ele ctronically approved. The approved document has a date entered in

This document is issued by means of

a computerized system.

The digitally stored original is ele

ctronically approved. The

approved document has a date entered

in the `Approved'-field.

A manual signature is not required.

Drawing sheet ISO 5457-A4T rev A

We reserve all rights in this document and in the information contained

therein. Reproduction, use or disclosure to third parties without express

authority is strictly fobidden. © Copyright 2015 ABB. All rights reserved.

D

C

B

E

F

1 2 3 4

40�$�

30�$�

54�$�

18�$�

72�$�

18�$�

54�$�

72�$�40�$�

30�$�

54�$�

18�$�

36�$�

36�$�

18�$�

54�$�

72�$�

40�$�

36�$�

18�$�18�$�

72�$�

18�$� 18�$�

36�$� 72�$�

40�$�

36�$�

18�$�18�$�

36�$�

36�$�

18�$� 18�$�

36�$� 72�$�

41,5�$�

36�$�

18�$�36�$�

9�$�

9�$�18�$�

36�$�

36�$�54�$�

36�$�

260 415

70�$�

70�$�

30�$�

70�$�

30�$�

70�$�

28,5�$�

68,5�$�

9�$�9�$�

ADDITIONAL DRAWINGS:Connection Diagrams:See Technical Guide UCMounting on active part: 54920103-1Accessories:54920103-2Motor Drive BUL2:1ZSC004106-AAEMotor Drive BUE:1ZSC004106-AAH or -AAJExternal Drive Shaft:54920083-4Pressure Relay:54920083-2Bevel Gear:54920083-1Holes for mounting of supportfor cleats and leads:1ZSC026099

3/3ENF1ZSC004528-ABZ

SheetLanguageRevisionDocument Id.

UCGR, UCGD E,T XXXX/300-1500/F 10-11,14-35 Pos

TAP-CHANGER UCGR,UCGD B(1ph) XXXX/300-600/F 10-11,14-35 Pos and

Title

DIMENSION DRAWING PGCO/TK2017-10-27

Document KindResponsible departmentDate / Approved

1/2

21

22

20

1/2

3/4

5/6

7/8

9/10

11/12

20-23 POSITIONS

A - AV

H

3/4

5/6

7/8

9/1021

22

20

16-19 POSITIONS

A - A

R297V

H

R297

Current Collector

21

22

20

1/2

3/45/6

7/8

9/10

11/12

13/14

24-27 POSITIONS

A - AV

H

21

22

20

1/2

3/45/6

7/8

9/10

11/12

13/14

15/16

28-31 POSITIONS

A - AV

H

21

22

20

1/2

3/45/6

7/8

9/10

11/12

13/1415/16

17/18

32-35 POSITIONS

A - AV

H