Upload
others
View
0
Download
0
Embed Size (px)
Citation preview
ARCUNID2
+DAR
CU
NID
2re
v. 0
6 12
/12/
2017
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it 1/12
Made in Italy
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
1 10 100
0 1 2
12
0
3456
78
9 12
0
3456
78
9 12
0
3456
78
9
IN 1
Com
IN 2
IN 3
1 10
pot
pot
pot Pot1-9V0-10V
Dmx-
Dmx+
GRD
10 100
DMX5
12>R
DM<
Vin=12-24-48 Vdc
[RGB+W]
350mA500mA (@ 0+2)700mA (@ 0+1+2)
NO
NO
NO
- Vin
ARCUNID2
DALI
DALI
DALI
DALI
DALI
+Vin
V in=1
2-48
Vdc
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2
350mA500mA (@ 0+2)700mA (@ 0+1+2)
350mA
500mA (@ 0+2)
700mA(@ 0+1+2)
- Vin
+Vin
1-10V
1100 10
12
0
35 46
7
98
12
0
35 46
7
98
12
0
3456
78
9
11 01 0 0
ARCUNID2
Push button SettingsInputs
12 Vdc24 Vdc48 Vdc
Controllers
NO push buttonPotentiometer1-9V1-10VDMX512/RDMDALI
Outputs (constant current)
350 mA (max 3 Led/ch; @Vin= 12Vdc500 mA (max 3 Led/ch; @Vin= 12Vdc700 mA (max 3 Led/ch; @Vin= 12Vdc
350 mA (max 6 Led/ch; @Vin= 24Vdc500 mA (max 6 Led/ch; @Vin= 24Vdc700 mA (max 6 Led/ch; @Vin= 24Vdc
350 mA (max 12 Led/ch; @Vin= 48Vdc500 mA (max 12 Led/ch; @Vin= 48Vdc700 mA (max 12 Led/ch; @Vin= 48Vdc
INITIAL OPERATING SETTINGS SET USING ROTARY SWITCHES (hundreds, tens, units)
000 address assignment and personality using RDM; 001 <-> 512 DMX address and personality selection using RDM; 513 <-> 599 Not valid (address assignment and personality using
RDM, as if it were “000”);>600 up Special functions (starting on p. 3).900 <-> 999 DALI function mode.Special functions:
Hundreds – Tens = function code;Units = number of inputs controlled or function parameter:
INITIAL SETTINGS FOR OUTPUT CURRENT TO SECONDARY CIRCUIT
INSTALLATION INSTRUCTIONS
Power supply units and control gear
ARCUNID2
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it2/12
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2
Vin=12-48 Vdc
350mA
- Vin
+Vin
500mA (@com+1)
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2- Vin
Vin=12-48 Vdc
+Vin
700mA (@ 0+1+2)
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
com
1 2- Vin
Vin=12-48 Vdc
+Vin
CONNECTING DEVICES TO SECONDARY CIRCUIT (CONSTANT CURRENT)
The 4 outputs of the secondary circuit work at constant current (350/500/700 mA); as a consequence, LED lighting devices can be connected that also work at constant current. Multiple devices can be connected to the same output by connecting the devices in series.
Only power up the system after all the devices and appliances have been connected!Do not connect the input (+Vin; -Vin) with an active power supply unit!
Connection in series using 4 channels Example: RGB+White device
Connection in series using 3 channelsExample: RGB device
To calculate the maximum number of devices that can be connected to a single output, check the operating voltage of each individual device (Vfapp), take into consideration the number of devices and total up the voltages Vftot. Vftot = Vfapp1 + Vfapp2 + ...It holds that: VFtot < Vinwhere Vin is the power supply voltage of the ARCUNID2.
For example, if a device is used with a power LED with Vfapp= 3.4Vdc, we shall have:
[max 3 Led @ Vin= 12Vdc]
[max 6 Led @ Vin= 24Vdc]
[max 12 Led @ Vin= 48Vdc]
Connection in series using 2 channels Example: dynamic white device
INSTALLATION INSTRUCTIONS
ARCUNID2
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it 3/12
IN 1
Com
IN 2
IN 3
1
NA
NA
NA
*47
12
0
35 46
7
98
12
0
35 46
7
98
12
0
3456
78
9*47
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vi
n
0 1 2- Vi
n
+Vin
OPERATING SETTINGS USING NO PUSH BUTTONS
Short press = on/off Long press (>1sec): regulates UP then DOWN alternately with every long press on the push button: when powered off, the last mode selected is stored.
740-741: 1 input on terminal IN 1, controls channels 1+2+3+4 simultaneously.IN 1: short press = on/off;
long press when powered on (>1 sec) = UP and DOWN dimming;
742: 2 inputs on terminals IN 1 and IN 2:IN 1: controls dimming through channels 1+2;IN 2: controls dimming through channels 3+4;
743: 3 inputs on terminals IN 1, IN 2 and IN 3:IN 1: controls dimming through channel 1;IN 2: controls dimming through channel 2;IN 3: controls dimming through channels 3;IN 2+IN3: controls dimming through channel 4;
800-805: RGB sequencer IN 1: short press = on/off;
double-click when powered off = 100% on; long press when powered on (>1 sec) = UP and DOWN dimming; long press when powered off (>1 sec) = 10% on;
IN 2: short press = colour cycle on/off;long press when powered off (>1 sec) = cycle time selection based on strobe frequency: 6 sec (fastest strobe), 30 sec, 6 min, 30 min (slowest strobe);
IN 3: short press = colour saturation (white) on/off;long press when powered off (>1 sec) = saturation change; long press when powered on (>1 sec) = minimum saturation;
806-809: RGBW sequencer IN 1: short press = on/off;
double-click when powered off = 100% on; long press when powered on (>1 sec) = UP and DOWN dimming; long press when powered off (>1 sec) = 10% on;
IN 2: short press = colour cycle on/off;long press when powered off (>1 sec) = cycle time selection based on strobe frequency: 6 sec (fastest strobe), 30 sec, 6 min, 30 min (slowest strobe);
IN 3: short press = colour saturation (white) on/off;long press when powered off (>1 sec) = saturation change; long press when powered on (>1 sec) = minimum saturation;
810: Dynamic whiteIN 1: short press = on/off;
long press (>1 sec) = UP and DOWN dimming;
IN 2: long press (>1 sec) = mixing channels 1+2 and 3+4;
820: Dimmer – on/off – 10% on channels 1+2+3+4 in parallel IN 1: short press = on/off;
double-click when powered off = 100% on; long press when powered on (>1 sec) = UP and DOWN dimming on channels 1+2+3+4; long press when powered off (>1 sec) = 10% on, on channels 1+2+3+4;
830: on/off on 4 channelsIN 1: short press = on/off on channels 1+2+3+4 simultaneously;
(Selector switch settings)
INSTALLATION INSTRUCTIONS
ARCUNID2
*07
12
0
35 46
7
98
12
0
35 46
7
98
12
0
3456
78
9*07
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it4/12
OPERATING SETTINGS USING ROTARY SWITCHES
The rotary switches can be used to manage the controller in stand-alone mode; after the desired functions have been selected, power up the system to perform the chosen light show. The settings may also be altered when the system is active. The available functions are given below:
700: Fixed colour yellow
701: Fixed colour cyan
702: Fixed colour green
703: Fixed colour magenta
704: Fixed colour red
705: Fixed colour blue
706: Fixed colour acquamarine
707: Fixed colour salmon pink
708: Fixed colour white from RGB (uses channels 1+2+3)
709: Fixed colour white from RGB-W (uses channels 1+2+3+4)
710: Fixed colour white W (uses channel 4)
711: Stand alone RGB-W sequence, speedy 1 (uses channels 1+2+3+4)
712: Stand alone cold colours sequence
713: Stand alone warm colours sequence
714: Stand alone RGB sequence, speedy 2 (uses channels 1+2+3)
715: Stand alone RGB-W speedy 2 (uses channels 1+2+3+4)
716: Stand alone RGB speedy 1 (uses channels 1+2+3)
717: Stand alone RGB-W speedy 4 (uses channels 1+2+3+4)
718: Stand alone RGB-W speedy 3 (uses channels 1+2+3+4)
719: Stand alone RGB speedy 3 (uses channels 1+2+3)
720: Stand alone pure colours RGB sequence (uses channels 1+2+3)
With the selector switches between 700 and 720, two NA push buttons can be used to control pre-set light shows:
- a short press on button 1 switches the device on if it is off;- a short press on button 1 plays the light shows one after the other, if the device is on;- a long press on button 1 switches the device off;- a long press on button 2 dims the lighting.
OPERATING SETTINGS USING 10 KOHM POTENTIOMETER / 0–10V / 1–9V
(Selector switch settings)
INSTALLATION INSTRUCTIONS
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it 5/12
ARCUNID2
*06
12
0
35 46
7
98
12
0
35 46
7
98
12
0
3456
78
9
*06
IN 1
Com
IN 2
IN 3
1 10
10V
0V10V
10V
IN 1
Com
IN 2
IN 3
1 10
9V
1VV9 V9
9V
IN 1
Com
IN 2
IN 3
1 10
pot
pot
pot
Control using 0–10V signal
(Selector switch settings)
600: 1 input on terminal IN 1, controls channels 1+2+3+4 simultaneously0-10V (between Com and IN 1): dimming between 1V (off) and 10V (100%);
602: 2 inputs on terminals IN 1 and IN 2:0-10V (between Com and IN 1): controls dimming through channels 1+2;0-10V (between Com and IN 2): controls dimming through channels 3+4;
603: 3 inputs on terminals IN 1, IN 2 and IN 3:0-10V (between Com and IN 1): controls dimming through channel 1;0-10V (between Com and IN 2): controls dimming through channel 2;0-10V (between Com and IN 3): controls dimming through channels 3+4;
Control using 1–9V signal
610: 1 input on terminal IN 1, controls channels 1+2+3+4 simultaneously1-9V (between Com and IN 1): dimming between 1V (off) and 9V (100%);
612: 2 inputs on terminals IN 1 and IN 2:1-9V (between Com and IN 1): controls dimming through channels 1+2;1-9V (between Com and IN 2): controls dimming through channels 3+4;
613: 3 inputs on terminals IN 1, IN 2 and IN 3:1-9V (between Com and IN 1): controls dimming through channel 1;1-9V (between Com and IN 2): controls dimming through channel 2;1-9V (between Com and IN 3): controls dimming through channels 3+4;
Control using 10 Kohm potentiometer
620: 1 input on terminal IN 1, controls channels 1+2+3+4 simultaneously10 Kohm pot (between Com and IN 1): dimming between 0% and 100%;
622: 2 inputs on terminals IN 1 and IN 2:10 Kohm pot (between Com and IN 1): controls dimming through channels 1+2;10 Kohm pot (between Com and IN 2): ccontrols dimming through channels 3+4;
623: 3 inputs on terminals IN 1, IN 2 and IN 3:10 Kohm pot (between Com and IN 1): controls dimming through channel 1;10 Kohm pot (between Com and IN 2): controls dimming through channel 2; 10 Kohm pot (between Com and IN 3): controls dimming through channels 3+4;
OPERATING SETTINGS USING DMX512 SIGNAL
INSTALLATION INSTRUCTIONS
ARCUNID2
Dmx-
Dmx+
DALI
DALI
GRD
10 100
DMX512
100
12
0
35 46
7
98
12
0
35 46
7
98
12
0
3456
78
9
000
215
12
0
35 46
7
98
12
0
35 46
7
98
12
0
3456
78
9
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2
350mA
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2
350mA
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI
0 1 2
Vin=12-48
Vdc
350mA
- Vin
- Vin
- Vin
DALI
DALI
+Vin
+Vin
+Vin
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it6/12
Control using DMX512 signal
001<->512: DMX start address selection; 4 addresses are used in total(for example, if 013 is set, the DMX addresses 13, 14, 15 and 16 will be occupied)
513<->599: invalid.
OPERATING SETTINGS USING DMX512 RDM SIGNAL
(Selector switch settings forDMX start address)
DMX512(Input)
<- max 200m ->shielded twisted pair cable: 2x0.5
max 32(unit)
120 Ohm(terminator 0,25W)
INSTALLATION INSTRUCTIONS
ARCUNID2
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it 7/12
Dmx-
Dmx+
GRD
10 100
DMX512>RDM<
000
12
0
35 46
7
98
12
0
35 46 56
7
98
12
0
34
78
9 RDM000
DALI
DALI
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2
350mA 350mA
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2
350mA
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI
0 1 2
Vin=12-48
Vdc
- Vin
- Vin
- Vin
+Vin
+Vin
+Vin
DALI
DALI
Control using DMX512 signal with RDM functionality
DMX512RDM
<- max 200m ->shielded twisted pair cable: 2x0.5
max 32(unit)
120 Ohm(terminator 0,25W)
000: signal input on terminals DMX-, DMX+ and GRD, address assignment using RDM.Personality selection using RDM.
513<->599: invalid.
Personality:
(Selector switch settings)
INSTALLATION INSTRUCTIONS
ARCUNID2
RDM
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it8/12
- 1 Dimmer (synchronised outputs) - 2 Shutter (synchronised outputs) - 3 RGB-W speedy ST7 (red, green, blue, white, sync, strobe, delay) - 4 RGB (red, green, blue) - 5 RGB+Dimmer (red, green, blue, dimmer) - 6 RGB-W (red, green, blue, white) - 7 RGB-W+Dimmer (red, green, blue, white, dimmer) - 8 RGB-W (red, green, blue, white) - 9 RGB-W speedy ST7 (red, green, blue, white, sync, strobe, delay) - 10 RGB-W (red, green, blue, white, sync, strobe, delay) – gamma curve –- 11 RGB-W (red, green, blue, white, sync, strobe, delay, dimmer) - 12 RGB-W 16 (red, green, blue, white, strobe, dimm. CTC fade freq.) - 13 RGB-W 16 + freq. - 14 RGB-W input 1–9V or push button (4 channels) - 15 RGB-W input 0–10V or push button (4 channels) - 16 RGB-W 1 potentiometer + push button - 17 RGB-W 3 potentiometer
RDMPROG01: DMX RDM programmer
This is a USB-DMX/RDM interface compatible with the E1.20 RDM and DMX USITT 1990 standards. It is powered directly from the USB port on the PC and is not affected by problems with different electrical potentials between the DMX line and the PC, even if it is disconnected and reconnected while in use: the built-in software immediately restores all the functions. RDMPROG01 allows bi-directional communication with RDM equipment over the DMX cable. The programmer has control software that uses the RDM protocol to recognise the lighting fixtures connected to the DMX; it is also possible to assign a DMX address in RDM mode by keying it into the corresponding program window.
MASTER / SLAVE CONNECTION WITH 3-CHANNEL RGB FUNCTION
INSTALLATION INSTRUCTIONS
ARCUNID2
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it 9/12
Master Slave Slave
NA
NA
NA
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2- Vin
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2- Vin
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
- Vin
0 1 2- Vin
Vin=12-48 Vdc
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
+Vin
DALI
DALI
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI IN
1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI
+Vin
+Vin
100
12
0
35 46
7
98
12
0
35 46 56
7
98
12
0
34
78
9
008
12
0
35 46
7
98
12
0
35 46 56
7
98
12
0
34
78
9
008
IN 1
Com
IN 2
IN 3
pot
pot
pot
IN 1
Com
IN 2
IN 3
1 10
10V
0V10V
10V
IN 1
Com
IN 2
IN 3
1 10
9V
1VV9 V9
9V
Other input types
Input<- max 200m ->
shielded twisted pair cable: 2x0.5max 32
(unit)120 Ohm
(terminator 0,25W)
(Selector setting in theMaster controller)
(Selector setting in allSlave controllers)
MASTER / SLAVE CONNECTION WITH DIMMER FUNCTION ON CHANNELS 1, 2, 3+4
INSTALLATION INSTRUCTIONS
ARCUNID2
100
12
0
35 46
7
98
12
0
35 46 56
7
98
12
0
34
78
9
347
12
0
35 46
7
98
12
0
35 46 56
7
98
12
0
3
478
9
347
NA
NA
NA
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
+Vin
- Vin
0 1 2- Vin
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
+Vin
- Vin
0 1 2- Vin
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
+Vin
- Vin
0 1 2- Vin
Vin=12-48 Vdc
Master Slave Slave
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI IN
1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI
IN 1
Com
IN 2
IN 3
pot
pot
pot
IN 1
Com
IN 2
IN 3
1 10
10V
0V10V
10V
IN 1
Com
IN 2
IN 3
1 10
9V
1VV9 V9
9V
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it10/12
Other input types
(Selector setting in theMaster controller)
(Selector setting in allSlave controllers)
Input<- max 200m ->
shielded twisted pair cable: 2x0.5max 32
(unit)120 Ohm
(terminator 0,25W)
MASTER / SLAVE CONNECTION WITH DYNAMIC WHITE FUNCTION
INSTALLATION INSTRUCTIONS
ARCUNID2
L&L Luce&Light / Via della Tecnica, 42 / 36031 Povolaro di Dueville, Vicenza / Italy / T +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it 11/12
100
12
0
35 46
7
98
12
0
35 46 56
7
98
12
0
34
78
9
018
12
0
35 46
7
98
12
0
35 46 56
7
98
12
0
34
78
9
018
NA
NA
500mA 700mA
Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
+Vin
- Vin
- Vin
0 1 2 Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
+Vin
- Vin
- Vin
0 1 2 Ch+
com
Ch1-
Ch2-
Ch3-
Ch4-
+Vin
+Vin
- Vin
- Vin
0 1 2
Vin=12-48 Vdc
Master Slave Slave
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALIIN
1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI
IN 1
Com
IN 2
IN 3
Dmx-
Dmx+
GRD
DALI
DALI
(Selector setting in theMaster controller)
(Selector setting in allSlave controllers)
Ingresso<- max 200m ->
shielded twisted pair cable: 2x0.5max 32
(unit)120 Ohm
(terminator 0,25W)
INSTALLATION INSTRUCTIONS
L&L Luce&Light
Via della Tecnica, 4236031 Povolaro di Dueville, Vicenza / ItalyT +39 0444 36 05 71 / F +39 0444 59 43 04E [email protected] / www.lucelight.it