"Examples of usage of HFC and ammonia systems in

public buildings and industry in Bosnia and Herzegovina"

Dr. sc. Gordana Tica, University of Banja Luka

Mr.sc. Fahrudin Kulić, University of Sarajevo

2

Page 3: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

EXAMPLES AND HISTORY OF HFC EQUIPMENT IN BOSNIA AND HERZEGOVINA

• All A/C equipment sold and installed in Bosnia and Herzegovina that uses refrigerants (split systems, chillers) is imported, only some auxiliary components such as ducts, piping and vents are produced locally.

• Most of this equipment is supplied by large, globally leading manufacturers of HVAC equipment such as YORK, TRANE, CARRIER, McQUAY.

• Other low cost brands are also present in the market but mostly for split systems. Bosnia and Herzegovina, as an Article 5 country of the Montreal Protocol, was obligated to stop using CFCs by January 1st, 2010 and replace them with HCFCs.

• However, these companies have started much earlier than required to supply HCFC and even HFC equipment to Bosnia and Herzegovina.

• The main reason is that the market of Bosnia and Herzegovina is small so they deliver the equipment according to EU requirements (non-A5) even though they are not required to do so.

3

Page 4: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

“Clima trade company” from Sarajevo, – is the authorized distributor of YORK equipment for Bosnia and

Herzegovina

A/C SPLIT SYSTEMS

• For the period 1997-2004, – employed exclusively R22 and approximately 3000 units were

sold in BiH.

• For the period 2005-2009, – employed R407c and approximately 3500 units were sold in BiH.

• For 2010– plans to sell around 400 split systems with HFCs (R407c and

R410a).

4

Page 5: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

LARGE A/C SYSTEMS

– For the period 1997-2000, • employed exclusively R22 and approximately 40 units were

sold in BiH

– For the period 2000-2004 • employed R407c and approximately 60 units were sold in BiH

– For the period 2004-2009, YORK A/C • chillers with cooling capacity under 150 kW employed R407c• units above 150 kW employed R134a and approximately 80

units were sold in BiH

5

Page 6: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

EXAMPLES OF HFC EQUIPMENT IN FBiH

-air cooled liquid chiller, cooling capacity 36 kW-

Refrigerant R407c:

1. Hotel Europa Garni, Sarajevo,, installed in 2003

2. Volksbank branch, Tuzla, installed in 2003

3. Hotel Bosnia, Sarajevo, installed in 2004

4. Avaz Twist Tower, Sarajevo, installed in 2009• air-cooled screw liquid chiller 570 kW cooling capacity, 3

units, refrigerant R134a

• air cooled liquid chiller, 70 kW cooling capacity, 2 units, refrigerant R407c

6

Page 7: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

Figure 1. Avaz Twist Tower/tollest building in BiH, 175m

7

Page 8: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

The next figure shows: a./the installation of the chiller

8

Page 9: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

9

b./ the drawing of the installation area

Page 10: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

Examples of HFC A/C equipments air cooled chiller has been provided by “Clima systems company” from Sarajevo, installed in 2009

• which is an authorized distributor of TRANE equipment for BiH,

1.Kumrovec Business and Shopping Centre,

1. 80 kW cooling capacity, 2 units, refrigerant R134a 2. 40 kW cooling capacity, refrigerant R407c

2. Alta Business and Shopping Centre,

1. 310 kW cooling capacity, 2 units, refrigerant R 134a

10

Page 11: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

Figure 3. Buildings with TRANE HFC chillers

Alta Business and Shopping Centre Kumrovec Business and Shopping Centre 11

Page 12: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

• According to the available information, in Sarajevo there was very little usage of CFCs in A/C equipment since the end of the war in 1995,– only HCFC and later HFC equipment has been installed.

• The equipment sold in the rest of the Federation of BiH used the same refrigerants.

• Sarajevo market is estimated at 1500 small split system annually and 20-50 large systems annually.

• YORK and LG equipment cover about 70% of the Sarajevo market, and rest of market are covered with McQuay, Ciat, Trane, Daikin, Carrier and low cost brands.

• Sarajevo market represents about 50% of the market in Federation of Bosnia and Herzegovina

12

Page 13: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

A few factories in Republic of Srpska work in continuity:1.Brewery “Pivara”2.“Vitaminka”- factory for thermics treatment of food

(coagulation, cooling, storage), etc.3.“Levita”- factory for thermics treatment of food4.“Frigo”- factory for thermics treatment of food

The big stores, with big refrigerant consumption:1.“Tempo”2.“Merkator 3.Interex”4.“Pevec” itd.

13

Page 14: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

Big consumption of cooling energy, i.e. refrigerants, hotels:

1. Hotel “Bosna” in the centre of town.

Big construction works that finished lately that on next objects in RS:

1. Building for Government2. Ministry buildings3.Television building and building

Alternative TV4. GP “Elektrodistribucija”

14

Page 15: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

.

All above mentioned works on bigger objects were performed by leading companies for A/C and cooling systems from Banja Luka.

This paper mainly covers the capital and bigger companies.

15

Page 16: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

I.

In a brewery, “Pivara” – refrigerant NH3 has been used as a main refrigerant

ever since the company was open (first beer production factory).

16

Page 17: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

• the factory owns the following equipment in which the refrigerant is:

R-22, R-134 A, and R-404a

1. A/C equipment -  producer  LG  and  YORK– Installated insade “Pivara”

     -  installed:  52 units  (  32 LG  + 20 YORK )- middle cooling capacity:  1500 W   - refrigerant : R 22- installation period  2005 - 2010 year 

17

Page 18: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

2.  Engine for beer infusion from barrels

– Installated in hotel-objects in RS and FBiH

- producer : VIČELI  Italy ,  OTPREMA 

Ludbreg,  CRO- install : 700 parts.- middle cooling capacity: 1000 W- refrigerant:   134 a- installation period : 1976 - 2010. 

18

Page 19: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

3. .  Refrigerant show case – installated in hotel-objects in RS and FBiH

- producer: UGUR  Turky . LTH  Slovenia- install: 2500 parts- middle cooling capacity: 1200 W - refrigerant: 134 a- installation period : 1996 - 2010 .

4. Compressed air drier – installated in compr. station

- producer : ATLAS COPCO  Belgium- install : 2  parts.- middle cooling capacity: 8050 W- refrigerant:   R 404 a ( 16 kg )- installation period : 1998.

19

Page 20: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

II. “Vitaminka”

• In process of thermic treatments, the factory has been using NH3.

• in production process, – are built 2 piston compressors  Bitzer, evaporator and

condensator

– Used R-407C

20

Page 21: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

III.Maxi -delta market “Tempo”

There are two units for cooling built:1. compressors with cooling capacity of 36,8kW, ti/tk

(-35/+45oC). Refrigerent: R-404A

2. compressors with cooling capacity of 197 kW, ti/tk (-10/+45oC). Refrigerent: R-404A.

21

Page 22: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

22

Company “ HOLLODEX” •is legal reperesentativer by firm YORK:

• time period from 1999 -2003:

Typ -unit MINI-SPLIT

Cooling capacity 2500 kW

Number of units Cca 550

refrigeration R-22

• time period from 2003-2008:

Typ unit MINI-SPLIT MINI-SPLIT Chiller Chiller

Cooling capacity 700 kW 2000 kW 1000 kW 60 kW

Number of units Cca 200 Cca 500 Cca 12 Cca 3

refrigeration R-22 R-407 R-407 R-410

Page 23: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

23

•time period from 2009 - april 2010

Typ unit MINI-SPLIT MINISPLIT Chiller Chiller

Cooling capacity 300 kW 150 800 kW 400 kW

Built, year 2009 - APRIL 2010

Number of units Cca 70 Cca 30 Cca 5 Cca 5

refrigeration R-407 R-410 R-407 R-410

Page 24: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

Company “KOSMITEH”, Banja Luka, • an official representative of the firm has “CARRIER”

performed the following works:

A/C SPLIT SYSTEMS- For period 1997-2004

• employed exclusively R22 – approximately 1800 units were sold in RS, power 3,5 to

3,8 kW.– For period 2005-2009

• approximately 1000 units were sold in RS, employed R22 (cca700) and R407c (cca300).

- For 2010, • around 100 split systems with HFCs (R407c and R410a).

24

Page 25: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

LARGE A/C SYSTEMS

– For the period 1997-2002, “• employed exclusively R22 • approximately 50 units were sold in RS, power from 40 to

160 kW.

– For the period 2002-2004, • employed R407c • approximately 50 units with cooling capacity up 40 kW sold

in RS.

– For the period 2004-2009, • cooling capacity from 40 to 750 kW employed R410 a and

R134 a, approximately 80 units were sold in RS.

25

Page 26: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

• List of installed “CARRIER” HFC equipments in RS:

1. Elektroprivreda Trebinje, heat pump, 2 x 240 kW, refrigerant R407c, installed in 2003

2. Narodno pozorište, Banja Luka, 1 x 140 kW cooling capacity, chiller , refrigerant R407c, installed in 2003

3. Building for Uprava indirektnog oporezivanja, I part, 2 x 70 kW, 1 x 40 kW, refrigerant R407c, heat pump, 2004

4. Hotel “Bosna”, cooling capacity 1 x x160 kW, and 1 x 60 kw, refrigerant R407c, 2005 to today.

5. MUP RS Banja luka 2x240, tp, chiller, 407c, 2004.6. Robna kuća “Damjan”, heat pump, cooling capacity 1x115vkW,

refrigerant R407c, 2005

26

Page 27: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

7. Robna kuća “Beneton”, heat pump, cooling capacity 66kW, refrigerant R407c, 2005

8. Robna kuća “Merkator”, Gradiška, cooling system, cooling capacity 262kW, refrigerant R410a, 2009

9. “Takovo”, Trebinje, Tool industry, cooling capacity 300 kW, refrigerant R410a, 2010

10. Integra “Termomontaža”, cooling system, 2 x 750 kW, refrigerant R134a, 2010.

11. Salon automobile “Vidović”, heat pump, cooling capacity 1x115vkW, refrigerant R407c, 2006/07.

12. Park “Petar Kočić”, heat pump, cooling capacity 1x115vkW, refrigerant R407c, 2007

13. Auto servis “Luburić, heat pump, cooling capacity 70 kW, refrigerant R407c, 2007

14. Mali “Merkator” na Starčevići , heat pump, cooling capacity 70 kW, refrigerant, R407c, 2008

15. Alf-om, poslovna jedinica, cooling capacity 1x200 kW and 1x 160 kW,2006

16. Kulturni centar, Gradiška , cooling capacity 300 kW, refrigerant R410a, 2007.

17. Robna kuca “Best”, 140 kW chiler R407c, 2008.27

Page 28: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

28

“Termomonaža”, contractor

• Difference provider by equipments

1. Typ unit Chiller

2. Cooling capacity 102.6 kW 125 kW 486 kW 275 kW 444 kW 291 kW

3. Producer "YORK" "YORK" "CARRIER" “CLIMAVENETA”

"CARRIER" “HITACHI”

4. Place of built AQUA PARK, BANJA LUKA

PO RAIFFEISEN BANKA, B. LUKA

ZGRADA VLADE RS, B. LUKA

DOM KULTURE, M. GRAD

TC „PEVEC“, B. LUKA

FOND ZDRAVSTVENOG OSIGURANJA RS, B. LUKA

5. Built, year 2006 2006 2007 2007 2008 2008

6. Number of units 1 1 3 1 2 17. refrigeration R407C R407C R134A R410A R134A R134A

Page 29: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

29

Typ unit With air cooling machine, typ 30RB0602

With air cooling machine, typ 30XA0752

Cooling agregat, typ KVA/Y/SSL 3602-B SPU

Chiller typ YLAE-HP0480

Cooling capacity 524 kW 706 kW 806 kW 469 kW

Producer "CARRIER" "CARRIER" “HIDRIA” “”

Place of built Hemofarm, B. LUKA

INTEGRA, B. LUKA

TC “MERCATOR”, B. LUKA

PRIVREDNI SUD, B. LUKA

Built, year 2008 2009 2009 2010

Number of units 1 2 2 1

refrigeration R134A R134A R134A R410A

Page 30: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

• Uplift chillers

30

Page 31: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

• Lift up the chillers to goverment building in Banja Luka

31

Page 32: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

32

Page 33: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic

33

Page 34: 09 Croatia Use Of Hfc And Ammonia Systems In Public Buildings And Industry Azra Rogovic