18" TELEPHONE WALL JACKS 48" MAX. 48" MAX. 48" HVAC CONTROLS PUSH BUTTON KEY SWITCH or FORWARD APPROACH STD. 18" FIN.FLR.LINE DUPLEX OUTLET 4" MIN. FIN.FLR.LINE PARALLEL APPROACH FIN.FLR.LINE PUSH BUTTON FIN.FLR.LINE KEY SWITCH or WALL COORDINATE WITH SCHEDULE DOOR DESIGNATION KEY NOTE DESIGNATION NUMBER - COORDINATE WITH PLAN NOTES COORDINATE WITH PLAN NOTES EQUIPMENT DESIGNATION NUMBER - ADDENDUM DESIGNATION NUMBER BULLETIN DESIGNATION NUMBER BLOCKING/ROUGH LUMBER BATT/LOOSE INSULATION ACOUSTICAL CEILING FINISHED WOOD GYPSUM WALLBOARD PARTICLE BOARD WALL TYPE DESIGNATION NUMBER - SHEET REFERENCE FOR DRAWING CONTINUATION PLYWOOD MASONRY GLASS CONCRETE 48" or DIMMER LIGHT SWITCH 4'-0" DESK MATCH LINE REF: A3 17 1 1 12 FIN.FLR.LINE 1 XXXX SW. SWITCH UNLESS NOTED OTHERWISE TONGUE AND GROOVE VINYL COMPOSITION TILE WELDED WIRE FABRIC W.W.F. U/C UNDERCUT WIDE VINYL BASE VERTICAL VERIFY IN FIELD WAINSCOT WATER CLOSET WEIGHT WOOD WINDOW W. W.C. WD.WIN. WT. WAINS. VERT. V.C.T. V.I.F. U.N.O. V.B. SYMMETRICAL TREAD THICK, THICKNESS THRESHOLD TERRAZZO TELEPHONE TOP AND BOTTOM TYPICAL TOP OF STEEL THRES. TYP. T.O.S. THK. T&G T&B TERR. TEL. SYM. T. MISCELLANEOUS IRON POUNDS PER SQUARE FOOT PROJECT, PROJECTION REINFORCED, REINFORCING REFLECTED CEILING PLAN R.B. RUBBER BASE SAN. SANITARY SCHEDULE SHEET STORAGE STRUCTURAL STANDARD SERVICE SINK SPECIFICATION STEEL SIMILAR SUSPENDED STRUCT. SUSP. STL. STOR. STD. SIM. SPEC. S.S. SCHED. SHT. ROOF CONDUCTOR RUBBER FLOORING ROOF SUMP ROOM REQUIRED ROOFING ROOF DRAIN RUBBER TILE R.S. R.T. REQ'D. RFG. RM. R.D. REINF. R.F. R.C.P. R.C. PLATE GLASS PLATE STEEL PLASTIC LAMINATE PREFABRICATED PAINT, POINT RISER PLASTER RETURN AIR PROJ. R. R.A. P.S.F. PT. PREFAB. P.LAM PLAS. PL.G. PL.S. MEZZANINE OUTSIDE DIAMETER NOT IN CONTRACT MASONRY OPENING MINIMUM ON CENTER NOT TO SCALE MISCELLANEOUS OPPOSITE OPENING N.I.C. O.D. OPP. OPNG. N.T.S. O.C. MIN. MISC. M.O. MEZZ. M.I. ELEVATION NUMBER DETAIL REFERENCE NUMBER ELEVATION NUMBER HEIGHT ABOVE FINISHED FLOOR REFERENCE POINT OF ELEVATION HEIGHT ABOVE FINISHED FLOOR EXISTING DOOR SYMBOL CIRCLES REPRESENT NEW COLUMN LINES LETTERS DESIGNATE HORIZONTAL COLUMN LINES DASHED CIRCLES REPRESENT EXISTING COLUMNS NUMBERS DESIGNATE VERTICAL COLUMN LINES SHEET NUMBER WHERE DETAIL IS REFERENCED NOTE: DATUM SYMBOL INDICATES A SPECIFIC REFERENCE HEIGHT OF MATERIAL INDICATED SHEET NUMBER WHERE DETAIL IS LOCATED SHEET NUMBER WHERE ELEVATION IS LOCATED DARKENED ARROW INDICATES ELEVATED SECTION SHEET NUMBER WHERE ELEVATION IS LOCATED NEW DOOR SYMBOL B A 1 1" = 1'-0" B./CEILING EL. 8'-0" A.F.F. 8'-0" ROOM NAME 0000000 A-8 ROOM NUMBER ROOM NAME DRAWING SCALE DETAIL A-8 12 12 1 A-5 A-5 1 2 DETAIL NAME DETAIL NUMBER FIBER REINFORCED PANELS EXPANSION, EXPOSED LONG LEG VERTICAL LONG LEG OUTSTANDING F.O. FACE OF JOINT LONG INSIDE DIAMETER MAXIMUM INTERIOR LAVATORY INSULATION METAL MECHANICAL LG. MAX. MET. MECH. L.L.O. L.L.V. LAV. JT. INSUL. I.D. INT. FACE OF STUD FRAME HORIZONTAL GYPSUM FOOTING HARDWARE GALVANIZED HOLLOW METAL GAUGE HEIGHT HORIZ. HT. GYP. HDW. H.M. FTG. GALV. GA. F.O.S. FR. EACH WAY FLOOR DRAIN FOUNDATION EXISTING EXTERIOR EXISTING FLOOR FINISH F.D. FLR. FIN. FDN. F.R.P. EXIST. EXP. EXT. EXG. E.W. DOWN EACH DIMENSION DIAMETER DRAWING DOOR OPENING DOOR CERAMIC TILE DETAIL CARPET ELEVATION DN. ELEV. DWG. EA. D.O. DR. DET. DIA. DM. CPT. C.T. ACOUSTIC CEILING TILE ABOVE FINISH FLOOR AT CORNER GUARD CEILING CONCRETE CLEAN OUT COLUMN CENTER LINE CONTROL JOINT CEMENT CONTINUOUS CORRUGATED CONSTRUCTION COL. CONST. CONT. CORR. CONC. C.G. L C.O. C CEM. CLG. C.J. ANODIZED ALUMINUM BUILDING BLOCKING BLOCK BOARD ACOUSTICAL ADJACENT ALUM. BLDG. BLKG. BLK. ANOD. BD. ACOUST. A.F.F. ADJ. A.C.T. @ FIELD VERIFY FV. L40 PS-5 L21 PS-6 045 088 L PS-2 056 KIRBY 202 PALMER 090 WILLIAMS MALL L31 ANTHONY WAYNE DRIVE LODGE FREEWAY U. S. 10 155 L51 167 156 150 L52 L53 L41 130 L41 134 L54 006 096 089 GULLEN MALL 008 017 001 005 022 007 016 023 CASS 034 136 140 025 027 040 050 043 053 049 026 028 033 039 036 048 046 042 038 060 CASS ANTOINETTE PS-1 062 PALMER PUTNAM 071 PS-3 637 499 E KIRBY 067 066 L34 064 FERRY PS 511 509 510 HENDRIE 195 199 085 082 065 L15 L35 L36 L23 L33 041 115 L32 051 498 L37 L58 207 LUDINGTON MALL GILMOUR MALL REUTHER MALL L22 38 087 104 JOHN R 070 127 HOLDEN AVE. YORK FOURTH L17 141 YORK O O W A R W D D ( THIRD ) 191 193 L11 E A S T W E S T 063 GULLEN MALL A R D CASS FERRY ST E PL ANTOINETTE PL 10 10 WEST WARREN L39 L20 GENERAL TS1.1 TITLE SHEET AND SHEET INDEX AND LOCATOR PLAN ISSUED FOR 07.09.15 90%OWNER REVIEW PREVIOUSLY ISSUED NOT ISSUED DRAWING INDEX KEY: REFERENCE ISSUED A1.1 FLOOR NOTE: THESE CONSTRUCTION DRAWINGS WERE PREPARED FOR COMPLIANCE WITH THE MICHIGAN CONSTRUCTION CODES IN EFFECT AT THE TIME OF PERMIT SUBMITTAL. ALL ENGINEERS, CONTRACTORS AND SUPPLIERS INVOLVED WITH THIS PROJECT SHALL COMPLY WITH THE SAME CODES, ISSUED AND APPROVED CODE MODIFICATIONS AND/OR CITY CODE AUTHORITY CONSTRUCTION BOARDS OF APPEALS RULINGS AND WHENEVER REQUIRED SHALL PROVIDE SHOP DRAWINGS AND SUBMITTALS CLEARLY DESCRIBING COMPLIANCE TO THE REGISTERED DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FOR REVIEW AND APPROVAL. VICINITY MAP NOT TO SCALE N PROJECT SITE D1.1 DEMO FLOOR PLAN/CEILING PLAN ARCHITECTURAL BUILDING CODE AUTHORITY: CITY OF DETROIT/ WAYNE STATE UNIVERSITY OWNER: WAYNE STATE UNIVERSITY 5454 CASS AVE. DETROIT, MI 48202 TYPE OF CONSTRUCTION: IIB,NON-SPRINKLED USE GROUP: B-Business A2.1 REFLECTED CEILING PLAN APPLICABLE CODES: BUILDING CODE ALSO KNOWN AS THE "MICHIGAN BUILDING CODE" 2012 MICHIGAN BUILDING CODE (MBC) AS AMENDED MECHANICAL CODE ALSO KNOWN AS THE "MICHIGAN MECHANICAL CODE" 2012 MICHIGAN MECHANICAL CODE AS AMENDED PLUMBING CODE ALSO KNOWN AS THE "MICHIGAN PLUMBING CODE" 2012 MICHIGAN PLUMBING CODE AS AMENDED ELECTRICAL CODE ALSO KNOWN AS THE "MICHIGAN ELECTRICAL CODE" 2011 NATIONAL ELECTRIC CODE (NEC) AS AMENDED & MICHIGAN AMMENDMENTS PART 8. ENERGY CODE 2009 UNIFORM ENERGY CODE BARRIER FREE REQUIREMENTS AMERICANS WITH DISABILITIES ACT (ADA) MBC-2009, CHAPTER 11 ICC / ANSI 117.1 - 2006, EXCEPT SECTION 611 & 707 9 A1.0 EXISTING PLAN, CODE STUDY & AREA OF WORK PLAN A2.2 REFLECTED CEILING PLAN DETAILS PS1.2 SPECIFICATIONS PS1.1 SPECIFICATIONS A7.1 MILLWORK DETAILS A6.1 INTERIOR ELEVATIONS A9.1 DOOR HARDWARE SCHEDULE F1.1 FINISH FLOOR PLAN - 1ST FLOOR MECHANICAL/PLUMBING ELECTRICAL M0.0 MECHANICAL SYMBOLS, LIST, INDEX AND NOTES ED1.1 PARTIAL DEMOLITION 1ST FLOOR PLAN - POWERS + SYSTEMS M0.1 MECHANICAL SPECIFICATIONS MD1.1 DEMOLITION FLOOR PLAN - MECHANICAL M1.1 NEW WORK FLOOR PLAN - MECHANICAL ED1.1 PARTIAL DEMOLITION 1ST + 2ND FLOOR PLANS - LIGHTING E0.1 ELEC. LEGENDS, SPEC., SHEET INDEX + LOAD SUMMARY E1.1 PARTIAL 1ST + 2ND FLOOR PLANS - LIGHTING E2.1 PARTIAL 1ST + 2ND FLOOR PLANS - POWER AND SYSTEMS 08.04.15 OWNER REVIEW F1.2 FINISH FLOOR PLAN - 2ND FLOOR WSU FP & M Project No.: 193-258618 WSU Building No.: 193 SVA Project No.: 2015.002 08.26.15 BIDS

060 - Procurement & Strategic Sourcing

  • Upload
    others

  • View
    11

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 060 - Procurement & Strategic Sourcing

18

"

TELEPHONE

WALL JACKS

48

" M

AX

.

48

" M

AX

.

48

"

HVAC CONTROLS

PUSH BUTTON

KEY SWITCH or

FORWARD APPROACH

ST

D.

18

" FIN.FLR.LINE

DUPLEX OUTLET

4" MIN.

FIN.FLR.LINE

PARALLEL APPROACH

FIN.FLR.LINE

PUSH BUTTON

FIN.FLR.LINE

KEY SWITCH or

WALL

COORDINATE WITH SCHEDULE

DOOR DESIGNATION

KEY NOTE DESIGNATION NUMBER -

COORDINATE WITH PLAN NOTES

COORDINATE WITH PLAN NOTES

EQUIPMENT DESIGNATION NUMBER -

ADDENDUM DESIGNATION NUMBER

BULLETIN DESIGNATION NUMBER

BLOCKING/ROUGH LUMBER

BATT/LOOSE INSULATION

ACOUSTICAL CEILING

FINISHED WOOD

GYPSUM WALLBOARD

PARTICLE BOARD

WALL TYPE DESIGNATION NUMBER -

SHEET REFERENCE FOR DRAWING CONTINUATION

PLYWOOD

MASONRY

GLASS

CONCRETE

48

"

or DIMMER

LIGHT SWITCH

4'-0

"

DESK

MATCH LINE

REF: A3

17

1

1

12

FIN.FLR.LINE

1

XX

XX

SW. SWITCH

UNLESS NOTED OTHERWISE

TONGUE AND GROOVE

VINYL COMPOSITION TILE

WELDED WIRE FABRICW.W.F.

U/C UNDERCUT

WIDE

VINYL BASE

VERTICAL

VERIFY IN FIELD

WAINSCOT

WATER CLOSET

WEIGHT

WOOD WINDOW

W.

W.C.

WD.WIN.

WT.

WAINS.

VERT.

V.C.T.

V.I.F.

U.N.O.

V.B.

SYMMETRICAL

TREAD

THICK, THICKNESS

THRESHOLD

TERRAZZO

TELEPHONE

TOP AND BOTTOM

TYPICAL

TOP OF STEEL

THRES.

TYP.

T.O.S.

THK.

T&G

T&B

TERR.

TEL.

SYM.

T.

MISCELLANEOUS IRON

POUNDS PER SQUARE FOOT

PROJECT, PROJECTION

REINFORCED, REINFORCING

REFLECTED CEILING PLAN

R.B. RUBBER BASE

SAN. SANITARY

SCHEDULE

SHEET

STORAGE

STRUCTURAL

STANDARD

SERVICE SINK

SPECIFICATION

STEEL

SIMILAR

SUSPENDED

STRUCT.

SUSP.

STL.

STOR.

STD.

SIM.

SPEC.

S.S.

SCHED.

SHT.

ROOF CONDUCTOR

RUBBER FLOORING

ROOF SUMP

ROOM

REQUIRED

ROOFING

ROOF DRAIN

RUBBER TILE

R.S.

R.T.

REQ'D.

RFG.

RM.

R.D.

REINF.

R.F.

R.C.P.

R.C.

PLATE GLASS

PLATE STEEL

PLASTIC LAMINATE

PREFABRICATED

PAINT, POINT

RISER

PLASTER

RETURN AIR

PROJ.

R.

R.A.

P.S.F.

PT.

PREFAB.

P.LAM

PLAS.

PL.G.

PL.S.

MEZZANINE

OUTSIDE DIAMETER

NOT IN CONTRACT

MASONRY OPENING

MINIMUM

ON CENTER

NOT TO SCALE

MISCELLANEOUS

OPPOSITE

OPENING

N.I.C.

O.D.

OPP.

OPNG.

N.T.S.

O.C.

MIN.

MISC.

M.O.

MEZZ.

M.I.

ELEVATION NUMBER

DETAIL REFERENCE NUMBER

ELEVATION NUMBER

HEIGHT ABOVE FINISHED FLOOR

REFERENCE POINT OF ELEVATION

HEIGHT ABOVE FINISHED FLOOR

EXISTING DOOR SYMBOL

CIRCLES REPRESENT NEW COLUMN LINES

LETTERS DESIGNATE HORIZONTAL COLUMN LINES

DASHED CIRCLES REPRESENT EXISTING COLUMNS

NUMBERS DESIGNATE VERTICAL COLUMN LINES

SHEET NUMBER WHERE DETAIL IS REFERENCED

NOTE: DATUM SYMBOL INDICATES A SPECIFIC

REFERENCE HEIGHT OF MATERIAL INDICATED

SHEET NUMBER WHERE DETAIL IS LOCATED

SHEET NUMBER WHERE ELEVATION IS LOCATED

DARKENED ARROW INDICATES ELEVATED SECTION

SHEET NUMBER WHERE ELEVATION IS LOCATED

NEW DOOR SYMBOL

B

A

1

1" = 1'-0"

B./CEILING

EL. 8'-0" A.F.F.

8'-0"

ROOM NAME

0000000

A-8

ROOM NUMBER

ROOM NAME

DRAWING SCALE

DETAIL

A-8

12

12

1

A-5

A-5

1

2

DETAIL NAME

DETAIL NUMBER

FIBER REINFORCED PANELS

EXPANSION, EXPOSED

LONG LEG VERTICAL

LONG LEG OUTSTANDING

F.O. FACE OF

JOINT

LONG

INSIDE DIAMETER

MAXIMUM

INTERIOR

LAVATORY

INSULATION

METAL

MECHANICAL

LG.

MAX.

MET.

MECH.

L.L.O.

L.L.V.

LAV.

JT.

INSUL.

I.D.

INT.

FACE OF STUD

FRAME

HORIZONTAL

GYPSUM

FOOTING

HARDWARE

GALVANIZED

HOLLOW METAL

GAUGE

HEIGHT

HORIZ.

HT.

GYP.

HDW.

H.M.

FTG.

GALV.

GA.

F.O.S.

FR.

EACH WAY

FLOOR DRAIN

FOUNDATION

EXISTING

EXTERIOR

EXISTING

FLOOR

FINISH

F.D.

FLR.

FIN.

FDN.

F.R.P.

EXIST.

EXP.

EXT.

EXG.

E.W.

DOWN

EACH

DIMENSION

DIAMETER

DRAWING

DOOR OPENING

DOOR

CERAMIC TILE

DETAIL

CARPET

ELEVATION

DN.

ELEV.

DWG.

EA.

D.O.

DR.

DET.

DIA.

DM.

CPT.

C.T.

ACOUSTIC CEILING TILE

ABOVE FINISH FLOOR

AT

CORNER GUARD

CEILING

CONCRETE

CLEAN OUT

COLUMN

CENTER LINE

CONTROL JOINT

CEMENT

CONTINUOUS

CORRUGATED

CONSTRUCTION

COL.

CONST.

CONT.

CORR.

CONC.

C.G.

L

C.O.

C

CEM.

CLG.

C.J.

ANODIZED

ALUMINUM

BUILDING

BLOCKING

BLOCK

BOARD

ACOUSTICAL

ADJACENT

ALUM.

BLDG.

BLKG.

BLK.

ANOD.

BD.

ACOUST.

A.F.F.

ADJ.

A.C.T.

@

FIELD VERIFYFV.

L40

PS-5

L21

PS

-6

045

088

L59A

PS-2

056

KIR

BY

202

PALMER

090

WILLIAMS MALL

L31

AN

TH

ON

Y W

AY

NE

D

RIV

E

LO

DG

E F

RE

EW

AY

U

. S

. 10

155

L51

167

156

150

L52

L53

L41

130

L41

134

L54

006

096

089

GU

LLE

N M

ALL

008

017

001

005

022

007

016

023

CA

SS

034

136

140

025

027

040

050

043

053

049

026

028

033

039

036

048

046

042

038

060

CA

SS

ANTOINETTE

PS-1

062

PA

LM

ER

PU

TN

AM

071

P

S

-3

637

499

E K

IR

BY

067

066

L

3

4

064F

E

R

R

Y

PS

5

1

1

509

510

H

E

N

D

R

IE

195

199

085

082

0

6

5

L15

L35

L36

L23

L33

041

115

L32

051

4

9

8

L37

L58

207

LUDINGTON MALL

GILMOUR MALL

REUTHER MALL

L22

38

087

104

JO

HN

R

0

7

0

127

H

O

L

D

E

N

A

V

E

.

YORK

FO

UR

TH

L17

141

YORK

O

O

W

A

R

W

D

D

( T

HIR

D )

191

193L11

E

A

S

T

W

E

S

T

063

GU

LLE

N M

ALL

A

R

D

CA

SS

FE

R

R

Y S

T E

PL

A

N

TO

IN

E

TT

E

PL

10

10

WEST WARREN

L39

L20

GENERAL

TS1.1 TITLE SHEET AND SHEET INDEX AND LOCATOR PLAN

ISSUED FOR

07

.0

9.1

5 9

0%

OW

NE

R R

EV

IE

W

PREVIOUSLY ISSUED

NOT ISSUED

DRAWING INDEX KEY:

REFERENCE

ISSUED

A1.1 FLOOR

NOTE:

THESE CONSTRUCTION DRAWINGS WERE PREPARED FOR COMPLIANCE WITH THE MICHIGAN

CONSTRUCTION CODES IN EFFECT AT THE TIME OF PERMIT SUBMITTAL. ALL ENGINEERS,

CONTRACTORS AND SUPPLIERS INVOLVED WITH THIS PROJECT SHALL COMPLY WITH THE

SAME CODES, ISSUED AND APPROVED CODE MODIFICATIONS AND/OR CITY CODE AUTHORITY

CONSTRUCTION BOARDS OF APPEALS RULINGS AND WHENEVER REQUIRED SHALL PROVIDE

SHOP DRAWINGS AND SUBMITTALS CLEARLY DESCRIBING COMPLIANCE TO THE REGISTERED

DESIGN PROFESSIONAL IN RESPONSIBLE CHARGE FOR REVIEW AND APPROVAL.

VICINITY MAP

NOT TO SCALE

N

PROJECT SITE

D1.1 DEMO FLOOR PLAN/CEILING PLAN

ARCHITECTURAL

BUILDING CODE AUTHORITY:

CITY OF DETROIT/ WAYNE STATE UNIVERSITY

OWNER:

WAYNE STATE UNIVERSITY

5454 CASS AVE.

DETROIT, MI 48202

TYPE OF CONSTRUCTION:

IIB,NON-SPRINKLED

USE GROUP:

B-Business

A2.1 REFLECTED CEILING PLAN

APPLICABLE CODES:

BUILDING CODE

ALSO KNOWN AS THE "MICHIGAN BUILDING CODE"

2012 MICHIGAN BUILDING CODE (MBC) AS AMENDED

MECHANICAL CODE

ALSO KNOWN AS THE "MICHIGAN MECHANICAL CODE"

2012 MICHIGAN MECHANICAL CODE AS AMENDED

PLUMBING CODE

ALSO KNOWN AS THE "MICHIGAN PLUMBING CODE"

2012 MICHIGAN PLUMBING CODE AS AMENDED

ELECTRICAL CODE

ALSO KNOWN AS THE "MICHIGAN ELECTRICAL CODE"

2011 NATIONAL ELECTRIC CODE (NEC) AS AMENDED &

MICHIGAN AMMENDMENTS PART 8.

ENERGY CODE

2009 UNIFORM ENERGY CODE

BARRIER FREE REQUIREMENTS

AMERICANS WITH DISABILITIES ACT (ADA)

MBC-2009, CHAPTER 11

ICC / ANSI 117.1 - 2006, EXCEPT SECTION 611 & 707

A1.0 EXISTING PLAN, CODE STUDY & AREA OF WORK PLAN

A2.2 REFLECTED CEILING PLAN DETAILS

PS1.2 SPECIFICATIONS

PS1.1 SPECIFICATIONS

A7.1 MILLWORK DETAILS

A6.1 INTERIOR ELEVATIONS

A9.1 DOOR HARDWARE SCHEDULE

F1.1 FINISH FLOOR PLAN - 1ST FLOOR

MECHANICAL/PLUMBING

ELECTRICAL

M0.0 MECHANICAL SYMBOLS, LIST, INDEX AND NOTES

ED1.1 PARTIAL DEMOLITION 1ST FLOOR PLAN - POWERS + SYSTEMS

M0.1 MECHANICAL SPECIFICATIONS

MD1.1 DEMOLITION FLOOR PLAN - MECHANICAL

M1.1 NEW WORK FLOOR PLAN - MECHANICAL

ED1.1 PARTIAL DEMOLITION 1ST + 2ND FLOOR PLANS - LIGHTING

E0.1 ELEC. LEGENDS, SPEC., SHEET INDEX + LOAD SUMMARY

E1.1 PARTIAL 1ST + 2ND FLOOR PLANS - LIGHTING

E2.1 PARTIAL 1ST + 2ND FLOOR PLANS - POWER AND SYSTEMS

08

.0

4.1

5 O

WN

ER

R

EV

IE

W

F1.2 FINISH FLOOR PLAN - 2ND FLOOR

WSU FP & M Project No.: 193-258618

WSU Building No.: 193

SVA Project No.: 2015.002

08

.2

6.1

5 B

ID

S

Page 2: 060 - Procurement & Strategic Sourcing

SECTION 01002

DEFINITIONS AND STANDARDS

1. The following is a general list of definitions as used in the specifications.

Architect/Engineer Refers to Stucky + Vitale Architects

Contractor Refers to the WSU

Subcontractor Refers to trades people having subcontractual agreements with the Contractor.

Owner Refers to the person, organization or authorized representative identified in the

contract documents.

Contract Documents Consist of the documents enumerated in the agreement and generally includes the contract

proposal, drawings and specifications.

Drawings Are diagramatic interpretations of the physical work to be performed on the project.

Work Refers to labor, materials, equipment and services related to the project.

Project Refers to total of the work to be performed including drawings, engineering and construction.

Change Order Is an order from the Owner or an agreement between the Owner and Contractor to make a change

in the project.

N.I.C. Is an abbreviation for "Not Included In Contract" and indicates that a particular item is not to be

included in the work to be done by the Contractor.

2. The following is a general list of technical societies referenced in the Specifications.

AIA American Institute of Architects

ACI American Concrete Institute

AIEE American Institute of Electrical Engineers

AISC American Institute of Steel Construction

AITC American Institute of Timber Construction

ASHRAE American Society of Heating, Refrigerating and Air Conditioning Engineers

ASME American Society of Mechanical Engineers

ASTM American Society for Testing and Materials

AWS American Welding Society

NAFM National Association of Fan Manufacturers

NEC National Electrical Code

NEMA National Electrical Manufacturer's Assoc.

RCSC Research Council on Structural Connections

UL Underwriters Laboratories

SECTION 01003

SPECIAL SUPPLEMENTARY CONDITIONS

1. PERMITS, TAPS AND FEES AND BONDS

The Contractor shall obtain building permits, test borings, surveys, licenses, certificates, inspections and other permits as

required.

The Contractor shall be fully reimbursed for the above items by the Owner upon proper transfer of all receipts.

Utility taps and fees and bonds shall be reimbursed by the Owner.

Plumbing, HVAC, Electrical and Signage subcontractors shall be responsible to obtain and pay for their own permits.

2. CUTTING AND PATCHING

EACH SUBCONTRACTOR shall be required to perform all cutting, patching and excavating necessary for his particular

work unless specifically stated otherwise.

The Contractor shall be responsible for COORDINATING the cutting and patching. The Contractor shall only perform

cutting and patching or fitting necessary for his own work and as necessary to assure that all parts and work of other

Subcontractors comes together properly.

3 . WORK BY OTHERS

The Owner agrees to provide any work and/or materials not an obligation of the Contractor at such time and in such a

manner so as not to delay the progress of the work of the Contractor.

4. OCCUPANCY BY OWNER

The Owner may occupy any part or parts of the work and use any equipment which is a reasonable degree of completion

(provided the building department will allow such) as will in his opinion make such areas or parts reasonable safe, fit, and

convenient for his use, under the conditions established for such occupancy.

5. RELOCATING OWNER'S EQUIPMENT

The Owner shall be responsible for and pay for the relocation and installation of any of his equipment.

SECTION 02225

DEMOLITION

Refer to Division 1 - General Requirements

1. Subcontractor shall provide all labor, materials, equipment, and incidentals necessary and required for the

completion of this Work.

2. Scope of Work shall include but not be limited to the following:

Selective demolition of building elements for alteration purposes.

3. Related Work by Others specified elsewhere:

Summary: Limitations on Contractor's use of site and premises.

Execution Requirements: Project conditions; protection of bench marks, survey control points, and existing construction

to remain; reinstallation of removed products; temporary bracing and shoring.

4. REFERENCE STANDARDS

29 CFR 1926 - U.S. Occupational Safety and Health Standards; current edition.

NFPA 241 - Standard for Safeguarding Construction, Alteration, and Demolition Operations

5. SUBMITTALS

Demolition Plan: Submit demolition plan as specified by OSHA and local authorities. Indicate extent of demolition,

removal sequence, bracing and shoring, and location and construction of barricades and fences. Identify demolition firm

and submit qualifications. Include a summary of safety procedures.

Project Record Documents: Accurately record actual locations of capped and active utilities and subsurface

construction.

6. SELECTIVE DEMOLITION FOR ALTERATIONS

Drawings showing existing construction and utilities are based on casual field observation and existing record

documents only. Verify that construction and utility arrangements are as shown. Report discrepancies to Architect before

disturbing existing installation. Beginning of demolition work constitutes acceptance of existing conditions that would be

apparent upon examination prior to starting demolition.

Separate areas in which demolition is being conducted from other areas that are still occupied. Provide, erect, and

maintain temporary dustproof partitions of construction indicated on drawings. Provide sound retardant partitions of

construction indicated on drawings in locations indicated on drawings.

Maintain weatherproof exterior building enclosure except for interruptions required for replacement or modifications; take

care to prevent water and humidity damage.

Remove existing work as indicated and as required to accomplish new work. Remove rotted wood, corroded metals, and

deteriorated masonry and concrete; replace with new construction specified.

Services (Including but not limited to HVAC, Plumbing, Fire Protection, Electrical, and Telecommunications): Remove

existing systems and equipment as indicated.

Maintain existing active systems that are to remain in operation; maintain access to equipment and operational

components.

Where existing active systems serve occupied facilities but are to be replaced with new services, maintain existing

systems in service until new systems are complete and ready for service.

Verify that abandoned services serve only abandoned facilities before removal. Remove abandoned pipe, ducts,

conduits, and equipment, including those above accessible ceilings; remove back to source of supply where

possible, otherwise cap stub and tag with identification.

Maintain existing integrity of wall rating with temporary construction as required.

Provide walk off mats and any additional components necessary to maintain a clean environment in spaces

adjacent to area or work.

Protect existing work to remain.

Prevent movement of structure; provide shoring and bracing if necessary.

Perform cutting to accomplish removals neatly and as specified for cutting new work.

Repair adjacent construction and finishes damaged during removal work.

Patch as specified for patching new work.

7. DEBRIS AND WASTE REMOVAL

Remove debris, junk, and trash from site. Leave site in clean condition, ready for subsequent work. Clean up spillage

and wind-blown debris from public and private lands.

SECTION 06010

CARPENTRY MATERIALS

Refer to Division 1 - General Requirements.

1. Subcontractor shall provide all labor, materials, equipment and incidentals necessary and required for the completion of

this work.

2. Scope of work shall include but not be limited to the following:

Rough Carpentry:

- Furnish lumber and materials for rough carpentry work, all lumber F.R.T.

3. Related Work Specified Elsewhere:

- Finish hardware, see Section 08712.

4. Coordinate material deliveries on an as-needed schedule with Carpentry Subcontractor and deliver and off-load at the

project site or location specified by Carpentry Subcontractor.

5. Provide all rough hardware, clamps, bolts, screws, anchors, galvanized metal plugs for securement to masonry (use no

wood plugs), as necessary. Coordinate installation locations with the masonry trades.

6. Furnish blocking, draftstops and firestops as necessary. All wood used to be fire retardant treated. (FRT)

SECTION 06100

CARPENTRY WORK

Refer to Division 1 - General Requirements.

1. Subcontractor shall provide all labor, materials, equipment and incidentals necessary and required for the completion of

this work.

2. Scope of work shall include but not be limited to the following:

Rough Carpentry:

- Frame interior partitions.

- Install wood grounds, nailers, blocking and backing for equipment.

Finish Carpentry:

- Install wood doors, see Section 08210.

- Install finish hardware, see Section 08712.

3. Related Work by others specified elsewhere:

- Supply carpentry materials, see Section 06010.

- All lumber used for roof nailers, curbs and cants, grounds or furring or to be used in contact with concrete or masonry shall

be preservative treated " wolmanized" or equal.

- All framing shall be plumb and true to line and level.

4. Install WOOD DOORS supplied by others, see Section 08210.

Cut and Trim to fit as necessary.

Hardware machining shall be done in the field except on fire rated doors which shall be machined in a certified shop.

5. Broom clean all spaces in preparation for the painter and clean and sand all soiled surfaces as required to receive painter's

finish.

6. Install FINISH HARDWARE supplied by others in accordance with manufacturer's standards and tag, index and file all

keys. See Section 08712.

7. Provide one year written guarantee for all carpentry work warranting all carpentry work against defective material and

improper workmanship.

8. The Subcontractor shall keep the premises and surrounding area free from the accumulation of waste materials or rubbish

caused by operations under contract. The Subcontractor shall be responsible for the complete removal and disposal of his

trade's debris.

SECTION 06650

SOLID SURFACE FABRICATIONS

PART 1 -- GENERAL

1.01RELATED DOCUMENTS

A. Drawings and general provisions of the contract, including general and supplementary conditions and Division 1 Specification Sections, apply

to this Section.

1.02SUMMARY

A. This Section includes the following horizontal and trim solid surface product types:

1. Countertops with integral sinks

B. Related Sections include the following:

1. Division 6 Section “Rough Carpentry” for Blocking.

2. Division 15 Section “Plumbing Fixtures.”

1.03DEFINITION

A. Solid surface is defined as nonporous, homogeneous material maintaining the same composition throughout the part with a composition of

acrylic polymer, aluminum trihydrate filler and pigment.

1.04SUBMITTALS

A. Product data:

1. For each type of product indicated.

2. Product data for the following:

B. Shop drawings:

1. Show location of each item, dimensioned plans and elevations, large-scale details, attachment devices and other components.

a. Show full-size details, edge details, thermoforming requirements, attachments, etc.

b. Show locations and sizes of furring, blocking, including concealed blocking and reinforcement specified in other Sections.

c. Show locations and sizes of cutouts and holes for plumbing fixtures, faucets, soap dispensers, waste receptacle and other items

installed in solid surface.

C. Samples:

1. For each type of product indicated.

a. Submit minimum 6-inch by 6-inch sample in specified gloss.

b. Cut sample and seam together for representation of inconspicuous seam.

c. Indicate full range of color and pattern variation.

d. Approved samples will be retained as a standard for work.

D. Product data:

1. Indicate product description, fabrication information and compliance with specified performance requirements.

1.05QUALITY ASSURANCE

A. Applicable standards:

1. Standards of the following, as referenced herein:

a. American National Standards Institute (ANSI)

b. American Society for Testing and Materials (ASTM)

c. National Electrical Manufacturers Association (NEMA)

d. 2. Fire test response characteristics:

1) Provide with the following Class A (Class I) surface burning characteristics as determined by testing identical products per UL 723

(ASTM E84) or another testing and inspecting agency acceptable to authorities having jurisdiction:

(a) Flame Spread Index: 25 or less.

(b) Smoke Developed Index: 450 or less.

B. Coordination drawings:

1. Shall be prepared indicating:

a. Plumbing work.

b. Electrical work.

c. Miscellaneous steel for the general work.

d. Indicate location of all walls (rated and non-rated), blocking locations and recessed wall items, etc.

1.06DELIVERY, STORAGE AND HANDLING

A. Deliver no components to project site until areas are ready for installation.

B. Handle materials to prevent damage to finished surfaces.

1. Provide protective coverings to prevent physical damage or staining following installation for duration of project.

1.07WARRANTY

A. Provide manufacturer's warranty against defects in materials.

1. Warranty shall provide material and labor to repair or replace defective materials.

2. Damage caused by physical or chemical abuse or damage from excessive heat will not be warranted.

1.08MAINTENANCE

A. Provide maintenance requirements as specified by the manufacturer.

PART 2 -- PRODUCTS

2.01 MANUFACTURERS

A. Manufacturers:

1. Subject to compliance with requirements, provide products by one of the following:

a. Corian® surfaces from the DuPont company (Group F).

2.02 MATERIALS

A. Solid polymer components

1. Cast, nonporous, filled polymer, not coated, laminated or of composite construction with through body colors meeting ANSI Z124.3 or ANSI

Z124.6, having minimum physical and performance properties specified.

2. Superficial damage to a depth of 0.010 inch (.25 mm) shall be repairable by sanding and/or polishing.

B. Thickness:

1. 3/4 inch

C. Edge treatment:

1. See Construction Documents

D. Integral sink: As indicated on the construction drawings.

E. Backsplash:

1. Applied.

F. H. Sidesplash:

1. Applied

G. Performance characteristics:

1. Property Typical Result Test

2. Tensile Strength 6,000 psi ASTM D 638

3. Tensile Modulus 1.5 x 10-6 psi ASTM D 638

4. Tensile Elongation 0.4% min. ASTM D 638

5. Flexural Strength 10,000 psi ASTM D 790

6. Flexural Modulus 1.2 x 10-6 psi ASTM D 790

7. Hardness >85 Rockwell “M” ScaleASTM D 785

8. ASTM D 785Barcol Impressor

9. Thermal Expansion 3.02 x 10-5 in./in./°CASTM D 696

10. (1.80 x 10-5 in./in./°F)

11. Gloss (60° Gardner)5-75 (matte-highly polished)ANSI Z124

12. Light Resistance(Xenon Arc) No effectNEMA LD 3-2000

13. Method 3.3

14. Wear and Cleanability PassesANSI Z124.3 & Z124.6

15. Stain Resistance: Sheets PassesANSI Z124.3 & Z124.6

16. Fungus and Bacteria ResistanceDoesn't support microbial growth ASTM G21&G22

17. Boiling Water Resistance No visible changeNEMA LD 3-2000

18. Method 3.5

19. High Temperature ResistanceNo changeNEMA LD 3-2000

20. Method 3.6

21. Izod Impact 0.28 ft.-lbs./in. of notchASTM D 256

22. (Notched Specimen) (Method A)

23. Ball Impact No fracture-1?2 lb. ball: NEMA LD 3-2000

24. Resistance: Sheets 1/4" slab-36" drop Method 3.8

25. 1/2" slab-144" drop

26. Weatherability E*94<5 in 1,000 hrs. ASTM G 155

27. Specific Gravity † 1.7

28. Water AbsorptionLong-term ASTM D 570

29. 0.4% (3/4")

30. 0.6% (1/2")

31. 0.8% (1/4")

32. Toxicity 99 (solid colors) Pittsburgh Protocol

33. 66 (patterned colors) Test (“LC50”Test)

34. Flammability All colors ASTM E 84,

35. (Class I and Class A)NFPA 255 &

36. UL 723

37. Flame Spread Index<25

38. Smoke Developed Index <25

2.03 ACCESSORIES

A. Joint adhesive:

1. Manufacturer's standard one- or two-part adhesive kit to create inconspicuous, nonporous joints.

B. Sealant:

1. Manufacturer's standard mildew-resistant, FDA-compliant, NSF 51-compliant, UL-listed silicone sealant in colors matching components.

2.04 FACTORY FABRICATION

A. A. Shop assembly

1. Fabricate components to greatest extent practical to sizes and shapes indicated, in accordance with approved shop drawings and

manufacturer's printed instructions and technical bulletins.

2. Form joints between components using manufacturer's standard joint adhesive without conspicuous joints.

a. Reinforce with strip of solid polymer material, 2" wide.

b. Provide factory cutouts for plumbing fittings and bath accessories as indicated on the drawings.

c. Rout and finish component edges with clean, sharp returns.

1) Rout cutouts, radii and contours to template.

2) Smooth edges.

3) Repair or reject defective and inaccurate work.

2.05 FINISHES

A. Select from the manufacturer's standard color chart.

1. Color:

a. See Schedule on Construction Documents.

B. Finish:

1. Provide surfaces with a uniform finish.

a. Matte; gloss range of 5-20.

PART 3 -- EXECUTION

3.01 EXAMINATION

A. Examine substrates and conditions, with fabricator present for compliance with requirements for installation tolerances and other conditions

affecting performance of work.

B. Proceed with installation only after unsatisfactory conditions have been corrected.

3.02 INSTALLATION

A. Install components plumb, level and rigid, scribed to adjacent finishes, in accordance with approved shop drawings and product data.

1. Provide product in the largest pieces available.

2. Form field joints using manufacturer's recommended adhesive, with joints inconspicuous in finished work.

3. Exposed joints/seams shall not be allowed.

4. Reinforce field joints with solid surface strips extending a minimum of 1 inch on either side of the seam with the strip being the same

thickness as the top.

5. Cut and finish component edges with clean, sharp returns.

6. Rout radii and contours to template.

7. Anchor securely to base cabinets or other supports.

8. Align adjacent countertops and form seams to comply with manufacturer's written recommendations using adhesive in color to match

countertop.

9. Carefully dress joints smooth, remove surface scratches and clean entire surface.

10. Install countertops with no more than 1/8-inch (3 mm) sag, bow or other variation from a straight line.

B. Coved backsplashes and applied sidesplashes:

1. Install applied sidesplashes using manufacturer's standard color-matched silicone sealant.

2. Adhere applied sidesplashes to countertops using manufacturer's standard color-matched silicone sealant.

C. Integral sinks/vanities:

1. Provide solid surface materials bowls and/or lavatories sinks with overflows in locations shown on the drawings.

2. Secure sinks and lavatory bowls to tops using manufacturer's recommended sealant, adhesive and mounting hardware to maintain

warranty.

3.03 REPAIR

A. Repair or replace damaged work which cannot be repaired to architect's satisfaction.

3.04 CLEANING AND PROTECTION

A. Keep components clean during installation.

B. Remove adhesives, sealants and other stains.

3.05 SCHEDULE

A. See Construction Documents

END OF SECTION

SECTION 08110

STEEL DOORS AND FRAMES

PART 1 GENERAL

1.01SECTION INCLUDES

A. Non-fire-rated steel doors and frames.

B. Fire-rated steel doors and frames.

C. Accessories, including glazing, louvers, and matching panels.

1.02REFERENCE STANDARDS

A. ANSI/ICC A117.1 - American National Standard for Accessible and Usable Buildings and Facilities; International Code Council; 2009.

B. ANSI A250.8 - SDI-100 Recommended Specifications for Standard Steel Doors and Frames; 2003 (R2008).

C. NAAMM HMMA 840 - Guide Specifications for Installation and Storage of Hollow Metal Doors and Frames; The National Association of

Architectural Metal Manufacturers; 2007.

D. NFPA 80 - Standard for Fire Doors and Other Opening Protectives; 2013.

E. UL (BMD) - Building Materials Directory; Underwriters Laboratories Inc.; current edition.

F. Steel Doors and Frames:

1. Assa Abloy Ceco, Curries, or Fleming: www.assaabloydss.com.

2.02 DOORS AND FRAMES

F. Requirements for All Doors and Frames:

1. Accessibility: Comply with ANSI/ICC A117.1.

2. Finish: Factory primed, for field finishing.

B. Combined Requirements: If a particular door and frame unit is indicated to comply with more than one type of requirement, comply with all the

specified requirements for each type; for instance, an exterior door that is also indicated as being sound-rated must comply with the

requirements specified for exterior doors and for sound-rated doors; where two requirements conflict, comply with the most stringent.

2.03 STEEL DOORS

A. Interior Doors, Non-Fire-Rated:

1. Grade: ANSI A250.8 - SDI-100; Level 2 - Heavy-Duty, Physical Performance Level B, Model 1 - Full Flush.

B. Interior Doors, Fire-Rated:

1. Grade: ANSI A250.8 - SDI-100; Level 2 - Heavy-Duty, Physical Performance Level B, Model 1 - Full Flush.

2. Fire Rating: As indicated on Door and Frame Schedule, tested in accordance with UL 10C ("positive pressure").

a. Provide units listed and labeled by UL (Underwriters Laboratories) - UL (BMD).

b. Attach fire rating label to each fire rated unit.

C. Panels: Same construction, performance, and finish as doors.

PART 3 EXECUTION

3.01 INSTALLATION

A. Install in accordance with the requirements of the specified door grade standard and NAAMM HMMA 840.

B. In addition, install fire rated units in accordance with NFPA 80.

C. Coordinate frame anchor placement with wall construction.

D. Coordinate installation of hardware.

END OF SECTION

SECTION 08115

STEEL DOOR FRAMES

PART 1 GENERAL

1.01SECTION INCLUDES

A. Non-fire-rated steel frames for non-steel doors.

B. Fire-rated steel door frames for non-steel doors.

C. Interior glazed light frames.

1.02REFERENCE STANDARDS

A. ANSI/ICC A117.1 - American National Standard for Accessible and Usable Buildings and Facilities; International Code Council; 2009.

B. ANSI A250.10 - Test Procedure and Acceptance Criteria for Prime Painted Steel Surfaces for Steel Doors and Frames; 1998 (R2011).

C. BHMA A156.115 - Hardware Preparation in Steel Doors and Steel Frames; 2006.

D. NFPA 80 - Standard for Fire Doors and Other Opening Protectives; 2013.

E. UL (BMD) - Building Materials Directory; Underwriters Laboratories Inc.; current edition.

F. UL 10C - Standard for Positive Pressure Fire Tests of Door Assemblies; Current Edition, Including All Revisions.

1.03DELIVERY, STORAGE, AND HANDLING

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Steel Frames with Integral Casings:

1. Assa Abloy Ceco, Curries, or Fleming: www.assaabloydss.com.

2.02 STEEL DOOR FRAMES - GENERAL REQUIREMENTS

A. Refer to Door and Frame Schedule on the drawings for frame sizes, fire ratings, sound ratings, finishing, door hardware to be installed, and

other variations, if any.

B. Door Frame Type: Provide steel door frames with either integral casing, for field finishing, or applied casings, prefinished.

C. Accessibility: Comply with ANSI/ICC A117.1.

D. Glazed Lights: Non-removable stops on non-secure side; sizes and configurations as indicated on drawings.

E. Combined Requirements: If a particular door and frame unit is indicated to comply with more than one type of requirement, comply with all the

specified requirements for each type; for instance, an exterior door that is also indicated as being sound-rated must comply with the

requirements specified for exterior doors and for sound-rated doors; where two requirements conflict, comply with the most stringent.

F. Hardware Preparation: In accordance with BHMA A156.115, with reinforcement welded in place, in addition to other requirements specified.

G. Frames for Interior Glazing or Borrowed Lights: Construction and face dimensions to match door frames, and as indicated on drawings.

2.03 STEEL DOOR FRAMES WITH INTEGRAL CASINGS

A. Finish: Factory primed, for field finishing.

B. Interior Door Frames, Non-Fire-Rated: Knockdown type.

1. Finish: Factory primed, for field finishing.

C. Interior Door Frames, Fire-Rated: Knockdown type.

1. Fire Rating: As indicated on Door and Frame Schedule, tested in accordance with UL 10C ("positive pressure").

a. Provide units listed and labeled by UL (Underwriters Laboratories) - UL (BMD).

b. Attach fire rating label to each fire rated unit.

2. Finish: Factory primed, for field finishing.

2.04 ACCESSORY MATERIALS

A. Silencers: Resilient rubber, fitted into drilled hole; 3 on strike side of single door, 3 on center mullion of pairs, and 2 on head of pairs without

center mullions.

2.05 FINISH MATERIALS

A. Primer: Rust-inhibiting, complying with ANSI A250.10, door manufacturer's standard.

PART 3 EXECUTION

3.01 INSTALLATION

A. Install frames in accordance with manufacturer's instructions and recommendations and as follows.

B. Install fire rated units in accordance with NFPA 80.

C. Coordinate frame anchor placement with wall construction.

D. Coordinate installation of glazing.

E. Coordinate installation of hardware.

3.02 TOLERANCES

A. Maximum Diagonal Distortion: 1/16 inch (1.6 mm) measured with straight edges, crossed corner to corner.

END OF SECTION

SECTION 08800

GLAZING

PART 1 GENERAL

1.01REFERENCE STANDARDS

A. 16 CFR 1201 - Safety Standard for Architectural Glazing Materials; current edition.

B. ASTM C1193 - Standard Guide for Use of Joint Sealants; 2013.

C. GANA (SM) - GANA Sealant Manual; Glass Association of North America; 2008.

D. ICC (IBC) - International Building Code; 2012.

PART 2 PRODUCTS

2.01 GLAZING TYPES

A. Type S-2 - Fire-Protection-Rated Glazing:

1. IBC Fire Protection Rating: D-H-T-60, minimum.

2. Safety Certification: 16 CFR 1201 Category II.

3. Applications: Provide this type of glazing in the following locations:

a. Fire windows.

b. Sidelights, borrow lites, and other glazed openings in partitions indicated as having an hourly fire rating.

4. Thickness: 1/4 inch (6 mm).

5. Glazing Method: As required for fire rating.

PART 3 EXECUTION

3.01 PREPARATION

A. Clean contact surfaces with solvent and wipe dry.

B. Seal porous glazing channels or recesses with substrate compatible primer or sealer.

C. Prime surfaces scheduled to receive sealant.

D. Install sealants in accordance with ASTM C1193 and GANA Sealant Manual.

E. Install sealant in accordance with manufacturer's instructions.

END OF SECTION

SECTION 08210

WOOD DOORS

Refer to Division 1 - General Requirements.

1. Subcontractor shall provide all materials and incidentals as required for the proper completion of this work.

2. Scope of work shall include the following:

- Prepare and provide shop drawings.

- Supply flush wood doors.

3. Related work by others specified elsewhere:

- Installation shall be by Carpentry Trades, see Section 06100.

4. Refer to Plans for location, size and swing of each door.

5. Submit four (4) sets of shop drawings for approval of Architect prior to commencing work.

6. Supply FLUSH WOOD DOORS.

Interior flush wood doors shall be solid core construction with wood veneer face panels for transparent finish.

WOOD VENEER FACE PANELS shall be selected. To be approved by Owner.

GRADE may be AWI PREMIUM where solid wood rails and stiles match the face veneer.

GRADE may be AWI CUSTOM only if solid wood rails and stiles match the face veneer.

DOOR CONSTRUCTION shall be SOLID CORE.

5 ply construction.

7. All doors shall have a two year full warranty against defects.

Provide two-year written guarantee warranting against defects in materials and workmanship.

8. Deliver and offload at site.

Installation shall be performed by Carpentry Trades, see Division 6.

Page 3: 060 - Procurement & Strategic Sourcing

SECTION 09051

COMMON WORK RESULTS FOR FLOORING PREPARATION

PART 1 GENERAL

1.01SECTION INCLUDES

A. This section applies to all floors identified in the contract documents as to receive the following types of floor coverings:

B. Removal of existing floor coverings.

C. Preparation of new and existing concrete floor slabs for installation of floor coverings.

D. Preparation of new and existing wood-based floors and subfloors for installation of new floor coverings.

1.02REFERENCES

A. ASTM C109/C109M - Standard Test Method for Compressive Strength of Hydraulic Cement Mortars (Using 2-in. or (50-mm) Cube

Specimens); 2013.

B. ASTM C472 - Standard Test Methods for Physical Testing of Gypsum, Gypsum Plasters and Gypsum Concrete; 1999 (Reapproved 2014).

C. RFCI (RWP) - Recommended Work Practices for Removal of Resilient Floor Coverings; Resilient Floor Covering Institute; October 2011.

PART 2 PRODUCTS

2.01 MATERIALS

A. Patching Compound: Floor covering manufacturer's recommended product, suitable for conditions, and compatible with adhesive and floor

covering. In the absence of any recommendation from flooring manufacturer, provide a product with the following characteristics:

1. Cementitious moisture-, mildew-, and alkali-resistant compound, compatible with floor, floor covering, and floor covering adhesive, and

capable of being feathered to nothing at edges.

2. Compressive Strength: 3000 psi, minimum, after 28 days, when tested in accordance with ASTM C109/C109M or ASTM C472, whichever

is appropriate.

B. Alternate Flooring Adhesive: Floor covering manufacturer's recommended product, suitable for the moisture and pH conditions present;

low-VOC. In the absence of any recommendation from flooring manufacturer, provide a product recommended by adhesive manufacturer as

suitable for substrate and floor covering and for conditions present.

C. Remedial Floor Coating: Single- or multi-layer coating or coating/overlay combination intended by its manufacturer to resist water vapor

transmission to degree sufficient to meet flooring manufacturer's emission limits, resistant to the level of pH found, and suitable for adhesion of

flooring without further treatment.

1. Thickness: 1/8 inch (3.2 mm), maximum.

2. If testing agency recommends any particular products, use one of those.

3. Products:

a. ARDEX Engineered Cements; ARDEX MC ULTRA, with ARDEX FEATHERFINISH: www.ardexamericas.com.

b. Floor Seal Technology, Inc; MES 100, with ARDEX K-15 or Mapei Ultraplan 1 Plus: www.floorseal.com.

c. Sika Corporation; Sikafloor Moisture Tolerance Epoxy Primer and Sikafloor Self-Leveling Moisture Tolerant Resurfacer:

www.sikafloorusa.com.

PART 3 EXECUTION

3.01 CONCRETE SLAB PREPARATION

A. Perform following operations in the order indicated:

1. Preliminary cleaning.

2. Specified remediation, if required.

3. Patching, smoothing, and leveling, as required.

4. Other preparation specified.

5. Adhesive bond and compatibility test.

6. Protection.

B. Remediations:

1. Active Water Leaks or Continuing Moisture Migration to Surface of Slab: Correct this condition before doing any other remediation; re-test

after correction.

2. Excessive Moisture Emission or Relative Humidity: If an adhesive that is resistant to the level of moisture present is available and

acceptable to flooring manufacturer, use that adhesive for installation of the flooring; if not, apply remedial floor coating over entire suspect

floor area.

3. Excessive pH: If remedial floor coating is necessary to address excessive moisture, no additional remediation is required; if not, if an

adhesive that is resistant to the level present is available and acceptable to the flooring manufacturer, use that adhesive for installation of

the flooring; otherwise, apply a skim coat of specified patching compound over entire suspect floor area.

3.02 REMOVAL OF EXISTING FLOOR COVERINGS

A. Comply with local, State, and federal regulations and recommendations of RFCI Recommended Work Practices for Removal of Resilient Floor

Coverings, as applicable to floor covering being removed.

B. Dispose of removed materials in accordance with local, State, and federal regulations and as specified.

3.03 PRELIMINARY CLEANING

A. Clean floors of dust, solvents, paint, wax, oil, grease, asphalt, residual adhesive, adhesive removers, film-forming curing compounds, sealing

compounds, alkaline salts, excessive laitance, mold, mildew, and other materials that might prevent adhesive bond.

B. Do not use solvents or other chemicals for cleaning.

3.04 PREPARATION

A. See individual floor covering section(s) for additional requirements.

B. Comply with requirements and recommendations of floor covering manufacturer.

C. Fill and smooth surface cracks, grooves, depressions, control joints and other non-moving joints, and other irregularities with patching

compound.

D. Do not fill expansion joints, isolation joints, or other moving joints.

3.05 ADHESIVE BOND AND COMPATIBILITY TESTING

A. Comply with requirements and recommendations of floor covering manufacturer.

3.06 APPLICATION OF REMEDIAL FLOOR COATING

A. Comply with requirements and recommendations of coating manufacturer.

3.07 PROTECTION

A. Cover prepared floors with building paper or other durable covering.

END OF SECTION

SECTION 08710

DOOR HARDWARE

PART 1 GENERAL

1.01SECTION INCLUDES

A. Hardware for hollow steel and aluminum doors.

B. Hardware for fire-rated doors.

C. .

1.02 REFERENCE STANDARDS

A. BHMA A156.4 - American National Standard for Door Controls - Closers; Builders Hardware Manufacturers Association, Inc.; 2008

(ANSI/BHMA A156.4).

B. BHMA A156.8 - American National Standard for Door Controls - Overhead Stops and Holders; Builders Hardware Manufacturers Association,

Inc.; 2010 (ANSI/BHMA A156.8).

C. NFPA 80 - Standard for Fire Doors and Other Opening Protectives; 2013.

D. UL (BMD) - Building Materials Directory; Underwriters Laboratories Inc.; current edition.

1.03 ADMINISTRATIVE REQUIREMENTS

A. Coordinate the manufacture, fabrication, and installation of products onto which door hardware will be installed.

1.04 QUALITY ASSURANCE

PART 2 PRODUCTS

2.01 MANUFACTURERS - BASIS OF DESIGN

A. Hager Companies products, for hinges, locks, closers, and other items specified: www.hagerco.com.

2.02 DOOR HARDWARE - GENERAL

A. Provide all hardware specified or required to make doors fully functional, compliant with applicable codes, and secure to the extent indicated.

B. Provide all items of a single type of the same model by the same manufacturer.

C. Provide products that comply with the following:

1. Applicable provisions of federal, state, and local codes.

2. Fire-Rated Doors: NFPA 80.

3. All Hardware on Fire-Rated Doors: Listed and classified by UL as suitable for the purpose specified and indicated.

4. Hardware for Smoke and Draft Control Doors (Indicated as "S" on Drawings): Provide hardware that enables door assembly to comply with

air leakage requirements of the applicable code.

D. Finishes: Identified in schedule.

2.03 HINGES

A. Hinges: Provide hinges on every swinging door.

1. Provide five-knuckle full mortise butt hinges unless otherwise indicated.

2. Provide ball-bearing hinges at all doors having closers.

3. Where electrified hardware is mounted in door leaf, provide power transfer hinges.

B. Quantity of Hinges Per Door:

1. Doors From 60 inches (1.5 m) High up to 90 inches (2.3 m) High: Three hinges.

2. Doors 90 inches (2.3 m) High up to 120 inches (3 m) High: Four hinges.

C. Manufacturers - Hinges:

1. Assa Abloy McKinney: www.assaabloydss.com.

2.04 LOCKS AND LATCHES

A. Locks: Provide a lock for every door, unless specifically indicated as not requiring locking.

1. Hardware Sets indicate locking functions required for each door.

2. If no hardware set is indicated for a swinging door provide an office lockset.

3. Trim: Provide lever handle or pull trim on outside of all locks unless specifically stated to have no outside trim.

4. Lock Cylinders: Provide key access on outside of all locks unless specifically stated to have no locking or no outside trim.

B. Lock Cylinders: Manufacturer's standard tumbler type, seven-pin Best Core, SFIC core.

1. Provide cams and/or tailpieces as required for locking devices required.

C. Keying: Keyed in like-groups.

1. Key to existing keying system.

D. Latches: Provide a latch for every door that is not required to lock, unless specifically indicated "push/pull" or "not required to latch".

2.05 CLOSERS

A. Closers: Complying with BHMA A156.4.

1. Provide surface-mounted, door-mounted closers unless otherwise indicated.

2. Provide a door closer on every exterior door.

3. Provide a door closer on every fire- and smoke-rated door. Spring hinges are not an acceptable self-closing device unless specifically so

indicated.

4. On pairs of swinging doors, if an overlapping astragal is present, provide coordinator to ensure the leaves close in proper order.

2.06 STOPS AND HOLDERS

A. Stops: Complying with BHMA A156.8; provide a stop for every swinging door, unless otherwise indicated.

1. Provide wall stops, unless otherwise indicated.

2. If wall stops are not practical, due to configuration of room or furnishings, provide overhead stop.

3. Stop is not required if positive stop feature is specified for door closer; positive stop feature of door closer is not an acceptable substitute

for a stop unless specifically so stated.

2. Scope of work shall include but not be limited to the following:

- Suspended metal grid for acoustical tile ceiling system.

- Acoustical ceiling tile units.

3. Related work by others specified elsewhere:

- Metal suspension system for drywall ceilings, see Section 09250.

4. Supply and install suspended metal ceiling grids compatible with the selected ceiling tiles.

Furnish and install Chicago Metallic Intermediate Duty "200" or equal metal grid suspension system with 10 gauge

galvanized soft steel wires and accompanying wall angles and cross tees to match indicated tile sizes. Space support wires

in accordance with manufacturers recommendations and secure to STRUCTURE above. Provide 8 gauge hanger clips for

steel beam flanges as needed. Match existing type used in facility.

Provide sufficient additional hangers at corners of light fixtures and at splices in the suspension members and at any other

locations recommended by the manufacturer.

See Color and Material Schedule for GRID COLOR.

5. Acoustical Tile Units shall be as indicated:

(See Color and Material Schedule on the plans)

6. Subcontractor shall SUBMIT LETTER OF INTENT stating that each item to be used shall be exactly as specified in the

Color and Material Schedule.

7. Provide one year written warranty against defects in materials and workmanship.

8. The Subcontractor shall keep the premises and surrounding area free from the accumulation of waste materials or rubbish

caused by operations under contract. The Subcontractor shall be responsible for the complete removal and disposal of his

trade's debris.

END OF SECTION

SECTION 09625

RESILIENT ATHLETIC FLOORING

PART 1 GENERAL

1.01SECTION INCLUDES

A. Rubber sheet flooring, adhesively installed.

B. Interlocking, loose-laid rubber tile.

C. Accessories.

1.02REFERENCE STANDARDS

A. ASTM D412 - Standard Test Methods for Vulcanized Rubber and Thermoplastic Elastomers--Tension; 2006a (Reapproved 2013).

1.03FIELD CONDITIONS

A. Maintain temperature in spaces to receive adhesively installed resilient flooring within range of 70-95 degrees F (21-35 degrees C) for not less

than 48 hours before the beginning of installation and for not less than 48 hours after installation has been completed. Subsequently, do not

allow temperature in installed spaces to drop below 50 degrees F (10 degrees C) or to go above 100 degrees F (38 degrees C).

PART 2 PRODUCTS

2.01 PREFORMED ATHLETIC FLOORING

A. Manufacturers: All products by the same manufacturer.

B. Rubber Sheet Flooring: Rubber roll goods comprising rubber granules from recycled automobile tires encapsulated in a zero-mercury

polyurethane binder, lengths to avoid transverse seams.

1. Thickness: Minimum 1/4 in (6.35 mm).

2. Sheet Width: Minimum 48 inches (1220 mm).

3. Tensile Strength: Minimum 150 psi (1.0 MPa), per ASTM D412.

4. Color: As scheduled.

C. Rubber Tile Flooring: Recycled rubber material formed into square tiles with invisible interlocking tabs, free-laid without adhesive.

1. Thickness: Minimum 1/4 in (6.35 mm).

2. Size: Nominal 24 in (600 mm) square.

3. Tensile Strength: Minimum 150 psi (1.0 MPa), per ASTM D412.

4. Surface Texture: Smooth.

5. Color: As selected from manufacturer's standards.

2.02 ACCESSORIES

A. Leveling Compound: Latex-modified cement formulation as recommended by flooring manufacturer for substrate conditions.

B. Adhesive: Water-resistant type recommended by flooring manufacturer for project conditions.

PART 3 EXECUTION

3.01 EXAMINATION

A. Examine substrates for conditions detrimental to installation of athletic flooring. Proceed with installation only after unsatisfactory conditions

have been corrected.

B. Verify that surfaces are flat to tolerances acceptable to flooring manufacturer, free of cracks that might telegraph through flooring, clean, dry,

and free of curing compounds, surface hardeners, and other chemicals that might interfere with bonding of athletic flooring to substrate.

3.02 PREPARATION

A. Remove coatings that are incompatible with flooring adhesives, using methods recommended by flooring manufacturer.

B. Broom clean areas to receive athletic flooring immediately before beginning installation.

3.03 INSTALLATION

A. Starting installation constitutes acceptance of sub-floor conditions.

B. Comply with manufacturer's recommendations and approved shop drawings.

C. Resilient Sheet Flooring:

1. Unroll flooring and allow to relax before beginning installation.

2. Mix adhesive thoroughly and apply to substrate with notched trowel. Roll flooring into fresh adhesive, overlapping end seams and double

cutting, butting factory edges and compression fitting.

3. Roll entire flooring surface with steel roller to assure adhesion to substrate and eliminate air bubbles.

4. Immediately remove any adhesive from flooring surface, using chemical recommended by flooring manufacturer.

5. Weld seams using techniques and equipment recommended by manufacturer.

6. Lay out game lines using tape and taping machine approved by flooring manufacturer. Apply game line paint with roller, and allow to dry

before removing tape.

7. Apply transparent top coat over flooring if recommended by manufacturer, to achieve a uniform finished appearance.

D. Rubber Tile Flooring:

1. Lay out center lines in spaces to receive tile flooring, based on location of principal walls. Start tile installation from center, and adjust as

necessary to avoid tiles less than one-half width at perimeter.

2. Lay tiles square with room axis, matching for color and pattern by selecting from cartons and mixing as recommended by manufacturer.

END OF SECTION

SECTION 09680

CARPET

PART 1 GENERAL

1.01SECTION INCLUDES

A. Carpet, direct-glued.

B. Accessories.

1.02REFERENCE STANDARDS

A. ASTM E 84 - Standard Test Method for Surface Burning Characteristics of Building Materials; 2005.

B. CRI (CIS) - Carpet Installation Standard; Carpet and Rug Institute; 2009.

C. CRI 104 - Standard for Installation of Commercial Textile Floorcovering Materials; Carpet and Rug Institute; 2002.

D. CRI (GLA) - Green Label Testing Program - Approved Adhesive Products; Carpet and Rug Institute; Current Edition.

E. NFPA 253 - Standard Method of Test for Critical Radiant Flux of Floor Covering Systems Using a Radiant Heat Energy Source; National Fire

Protection Association; 2011.

1.03SUBMITTALS

A. See Section 01300 - Administrative Requirements, for submittal procedures.

B. Shop Drawings: Indicate seaming plan, method of joining seams, direction of carpet pile and pattern, location of edge moldings and edge

bindings.

C. Product Data: Provide data on specified products, describing physical and performance characteristics; sizes, patterns, colors available, and

method of installation.

D. Samples: Submit two samples in size illustrating color and pattern for each carpet and cushion material specified.

E. Manufacturer's Installation Instructions: Indicate special procedures and perimeter conditions requiring special attention.

F. Maintenance Data: Include maintenance procedures, recommended maintenance materials, and suggested schedule for cleaning.

1.04QUALITY ASSURANCE

A. Manufacturer Qualifications: Company specializing in manufacturing specified carpet with minimum three years documented experience.

B. Installer Qualifications: Company specializing in installing carpet with minimum three years documented experience.

1.05FIELD CONDITIONS

A. Store materials in area of installation for minimum period of 24 hours prior to installation.

B. Maintain minimum 70 degrees F (21 degrees C) ambient temperature 24 hours prior to, during and 24 hours after installation.

C. Ventilate installation area during installation and for 72 hours after installation.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Carpet:

1. Refer to schedule on Drawings.

2. Substitutions: See Section 01600 - Product Requirements.

2.02 CARPET

A. Carpet:

1. Surface Burning Characteristics: Flame spread/Smoke developed index of 450/25, maximum, when tested in accordance with ASTM E 84.

2.03 ACCESSORIES

A. Sub-Floor Filler: Type recommended by carpet manufacturer.

B. Adhesives - General: Compatible with materials being adhered; maximum VOC content of 50 g/L; CRI Green Label certified.

C. Seam Adhesive: Recommended by manufacturer.

D. Contact Adhesive: Compatible with carpet material; releasable type.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that sub-floor surfaces are smooth and flat within the tolerances specified for that type of work and are ready to receive carpet.

B. Verify that sub-floor surfaces are dust-free and free of substances that could impair bonding of adhesives to sub floor surfaces.

C. Verify that concrete sub-floor surfaces are dry enough and ready for adhesive installation by testing for moisture emission rate and alkalinity in

accordance with ASTM F710; obtain instructions if test results are not within limits recommended by carpet manufacturer and adhesive

materials manufacturer.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that doors and frames are ready to receive work; labeled, fire-rated doors and frames are present and properly installed, and dimensions

are as indicated on shop drawings.

3.02 INSTALLATION

A. Install hardware in accordance with manufacturer's instructions and applicable codes.

B. Use templates provided by hardware item manufacturer.

C. Install hardware on fire-rated doors and frames in accordance with code and NFPA 80.

D. Mounting heights for hardware from finished floor to center line of hardware item: As listed in Schedule, unless otherwise noted:

3.03 ADJUSTING

A. Adjust hardware for smooth operation.

END OF SECTION

SECTION 09260

GYPSUM BOARD ASSEMBLIES

PART 1 GENERAL

1.01SECTION INCLUDES

A. Performance criteria for gypsum board assemblies.

B. Metal stud wall framing.

C. Metal channel ceiling framing.

D. Acoustic insulation.

E. Gypsum wallboard.

F. Joint treatment and accessories.

1.02RELATED REQUIREMENTS

A. Section 06100 - Rough Carpentry: Wood blocking product and execution requirements.

1.03REFERENCE STANDARDS

A. ASTM C475/C475M - Standard Specification for Joint Compound and Joint Tape for Finishing Gypsum Board; 2012.

B. ASTM C645 - Standard Specification for Nonstructural Steel Framing Members; 2013.

C. ASTM C665 - Standard Specification for Mineral-Fiber Blanket Thermal Insulation for Light Frame Construction and Manufactured Housing;

2012.

D. ASTM C754 - Standard Specification for Installation of Steel Framing Members to Receive Screw-Attached Gypsum Panel Products; 2011.

E. ASTM C840 - Standard Specification for Application and Finishing of Gypsum Board; 2013.

F. ASTM C954 - Standard Specification for Steel Drill Screws for the Application of Gypsum Panel Products or Metal Plaster Bases to Steel Studs

From 0.033 in. (0.84 mm) to 0.112 in. (2.84 mm) in Thickness; 2011.

G. ASTM C1002 - Standard Specification for Steel Self-Piercing Tapping Screws for the Application of Gypsum Panel Products or Metal Plaster

Bases to Wood Studs or Steel Studs; 2007 (Reapproved 2013).

H. ASTM C1396/C1396M - Standard Specification for Gypsum Board; 2014.

I. ASTM C1629/C1629M - Standard Classification for Abuse-Resistant Nondecorated Interior Gypsum Panel Products and Fiber-Reinforced

Cement Panels; 2006 (Reapproved 2011).

J. ASTM D3273 - Standard Test Method for Resistance to Growth of Mold on the Surface of Interior Coatings in an Environmental Chamber;

2012.

K. ASTM E90 - Standard Test Method for Laboratory Measurement of Airborne Sound Transmission Loss of Building Partitions and Elements;

2009.

L. ASTM E413 - Classification for Rating Sound Insulation; 2010.

M. GA-216 - Application and Finishing of Gypsum Board; Gypsum Association; 2013.

PART 2 PRODUCTS

2.01 GYPSUM BOARD ASSEMBLIES

A. Provide completed assemblies complying with ASTM C840 and GA-216.

B. Interior Partitions Indicated as Acoustic: Provide completed assemblies with the following characteristics:

1. Acoustic Attenuation: STC of 45-49 calculated in accordance with ASTM E413, based on tests conducted in accordance with ASTM E90.

C. Fire Rated Assemblies: Provide completed assemblies complying with applicable code.

2.02 METAL FRAMING MATERIALS

A. Non-Loadbearing Framing System Components: ASTM C645; galvanized sheet steel, of size and properties necessary to comply with ASTM

C754 for the spacing indicated, with maximum deflection of wall framing of L/240 at 5 psf (240 Pa).

1. Studs: "C" shaped with flat or formed webs with knurled faces.

2. Runners: U shaped, sized to match studs.

3. Ceiling Channels: C shaped.

B. Ceiling Hangers: Type and size as specified in ASTM C754 for spacing required.

C. Partition Head To Structure Connections: Provide track fastened to structure with legs of sufficient length to accommodate deflection, for

friction fit of studs cut short and fastened as indicated on drawings.

2.03 BOARD MATERIALS

A. Manufacturers - Gypsum-Based Board:

1. American Gypsum: www.americangypsum.com.

2. Georgia-Pacific Gypsum: www.gpgypsum.com.

3. USG Corporation: www.usg.com.

B. Gypsum Wallboard: Paper-faced gypsum panels as defined in ASTM C1396/C1396M; sizes to minimize joints in place; ends square cut.

1. Application: Use for vertical surfaces and ceilings, unless otherwise indicated.

2. Mold Resistance: Score of 10, when tested in accordance with ASTM D3273.

a. Mold-resistant board is required whenever board is being installed before the building is enclosed and conditioned.

3. Thickness:

a. Vertical Surfaces: 1/2 inch (13 mm).

C. Abuse-Resistant Wallboard:

1. Application: High-traffic areas indicated.

2. Mold Resistance: Score of 10, when tested in accordance with ASTM D3273.

3. Type: Fire-resistance rated Type X, UL or WH listed.

4. Thickness: 5/8 inch (16 mm).

5. Edges: Tapered.

2.04 ACCESSORIES

A. Acoustic Insulation: ASTM C665; preformed glass fiber, friction fit type, unfaced.

B. Joint Materials: ASTM C475 and as recommended by gypsum board manufacturer for project conditions.

C. High Build Drywall Surfacer: Vinyl acrylic latex-based coating for spray application, designed to take the place of skim coating and separate

paint primer in achieving Level 5 finish.

D. Screws for Attachment to Steel Members Less Than 0.03 inch (0.7 mm) In Thickness, to Wood Members, and to Gypsum Board: ASTM

C1002; self-piercing tapping type; cadmium-plated for exterior locations.

E. Screws for Attachment to Steel Members From 0.033 to 0.112 inch (0.8 to 2.8 mm) in Thickness: ASTM C954; steel drill screws for application

of gypsum board to loadbearing steel studs.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that project conditions are appropriate for work of this section to commence.

3.02 FRAMING INSTALLATION

A. Metal Framing: Install in accordance with ASTM C754 and manufacturer's instructions.

B. Suspended Ceilings and Soffits: Space framing and furring members as indicated.

1. Level ceiling system to a tolerance of 1/1200.

2. Laterally brace entire suspension system.

C. Studs: Space studs as permitted by standard.

1. Extend partition framing to structure where indicated and to ceiling in other locations.

2. Partitions Terminating at Ceiling: Attach ceiling runner securely to ceiling track in accordance with manufacturer's instructions.

3. Partitions Terminating at Structure: Attach extended leg top runner to structure, maintain clearance between top of studs and structure, and

brace both flanges of studs with continuous bridging.

D. Openings: Reinforce openings as required for weight of doors or operable panels, using not less than double studs at jambs.

E. Blocking: Install wood blocking for support of:

1. Framed openings.

2. Wall mounted cabinets.

3. Televisions

3.03 ACOUSTIC ACCESSORIES INSTALLATION

A. Acoustic Insulation: Place tightly within spaces, around cut openings, behind and around electrical and mechanical items within partitions, and

tight to items passing through partitions.

B. Acoustic Sealant: Install in accordance with manufacturer's instructions.

3.04 BOARD INSTALLATION

A. Comply with ASTM C 840, GA-216, and manufacturer's instructions. Install to minimize butt end joints, especially in highly visible locations.

B. Fire-Rated Construction: Install gypsum board in strict compliance with requirements of assembly listing.

3.05 JOINT TREATMENT

A. Finish gypsum board in accordance with levels defined in ASTM C840, as follows:

1. Level 4: Walls and ceilings to receive paint finish or wall coverings, unless otherwise indicated.

2. Level 1: Fire rated wall areas above finished ceilings, whether or not accessible in the completed construction.

B. Tape, fill, and sand exposed joints, edges, and corners to produce smooth surface ready to receive finishes.

1. Feather coats of joint compound so that camber is maximum 1/32 inch (0.8 mm).

C. Where Level 5 finish is indicated, spray apply high build drywall surfacer over entire surface after joints have been properly treated; achieve a

flat and tool mark-free finish.

3.06 TOLERANCES

A. Maximum Variation of Finished Gypsum Board Surface from True Flatness: 1/8 inch in 10 feet (3 mm in 3 m) in any direction.

END OF SECTION

SECTION 09511

ACOUSTICAL WORK

Refer to Division 1 - General Requirements.

1. Subcontractor shall provide all labor, materials, equipment and incidentals necessary and required for the completion of

this work.

3.02 PREPARATION

A. Remove sub-floor ridges and bumps. Fill minor or local low spots, cracks, joints, holes, and other defects with sub-floor filler.

B. Apply, trowel, and float filler to achieve smooth, flat, hard surface. Prohibit traffic until filler is cured.

C. Clean substrate.

3.03 INSTALLATION - GENERAL

A. Starting installation constitutes acceptance of sub-floor conditions.

B. Install carpet and cushion in accordance with manufacturer's instructions and CRI Carpet Installation Standard.

C. Install carpet and cushion in accordance with manufacturer's instructions and CRI 104.

D. Verify carpet match before cutting to ensure minimal variation between dye lots.

E. Lay out carpet and locate seams in accordance with shop drawings:

1. Locate seams in area of least traffic, out of areas of pivoting traffic, and parallel to main traffic.

2. Do not locate seams perpendicular through door openings.

3. Align run of pile in same direction as anticipated traffic and in same direction on adjacent pieces.

4. Locate change of color or pattern between rooms under door centerline.

5. Provide monolithic color, pattern, and texture match within any one area.

F. Install carpet tight and flat on subfloor, well fastened at edges, with a uniform appearance.

3.04 DIRECT-GLUED CARPET

A. Double cut carpet seams, with accurate pattern match. Make cuts straight, true, and unfrayed. Apply seam adhesive to cut edges of woven

carpet immediately.

B. Apply contact adhesive to floor uniformly at rate recommended by manufacturer. After sufficient open time, press carpet into adhesive.

C. Apply seam adhesive to the base of the edge glued down. Lay adjoining piece with seam straight, not overlapped or peaked, and free of gaps.

D. Roll with appropriate roller for complete contact of adhesive to carpet backing.

E. Trim carpet neatly at walls and around interruptions.

3.05 CLEANING

A. Remove excess adhesive from floor and wall surfaces without damage.

B. Clean and vacuum carpet surfaces.

END OF SECTION

SECTION 09685

CARPET TILE

PART 1 GENERAL

1.01SECTION INCLUDES

A. Carpet tile, fully adhered.

B. Removal of existing carpet tile.

1.02RELATED REQUIREMENTS

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. See Drawings; Product as noted.

2.02 MATERIALS

A. Carpet Tile: Tufted, manufactured in one color dye lot.

1. Product: See Drawings manufactured by As noted.

PART 3 EXECUTION

3.01 EXAMINATION

A. Verify that sub-floor surfaces are smooth and flat within tolerances specified for that type of work and are ready to receive carpet tile.

B. Verify that wall surfaces are smooth and flat within the tolerances specified for that type of work, are dust-free, and are ready to receive carpet

tile.

C. Verify that sub-floor surfaces are dust-free and free of substances that could impair bonding of adhesive materials to sub-floor surfaces.

3.02 PREPARATION

A. Remove existing carpet tile.

3.03 INSTALLATION

A. Starting installation constitutes acceptance of sub-floor conditions.

B. Install carpet tile in accordance with manufacturer's instructions and CRI Carpet Installation Standard.

C. Blend carpet from different cartons to ensure minimal variation in color match.

D. Cut carpet tile clean. Fit carpet tight to intersection with vertical surfaces without gaps.

E. Lay carpet tile in square pattern, with pile direction parallel to next unit, set parallel to building lines.

F. Fully adhere carpet tile to substrate.

G. Trim carpet tile neatly at walls and around interruptions.

H. Complete installation of edge strips, concealing exposed edges.

3.04 CLEANING

A. Remove excess adhesive without damage, from floor, base, and wall surfaces.

B. Clean and vacuum carpet surfaces.

END OF SECTION

SECTION 09900

PAINTS AND COATINGS

PART 1 GENERAL

1.01SECTION INCLUDES

A. Surface preparation.

B. Field application of paints, stains, varnishes, and other coatings.

C. Scope: Finish all interior and exterior surfaces exposed to view, unless fully factory-finished and unless otherwise indicated, including the

following:

D. Do Not Paint or Finish the Following Items:

1. Items fully factory-finished unless specifically so indicated; materials and products having factory-applied primers are not considered

factory finished.

2. Items indicated to receive other finishes.

3. Items indicated to remain unfinished.

4. Fire rating labels, equipment serial number and capacity labels, and operating parts of equipment.

5. Floors, unless specifically so indicated.

6. Glass.

7. Concealed pipes, ducts, and conduits.

PART 2 PRODUCTS

2.01 MANUFACTURERS

A. Provide all paint and coating products used in any individual system from the same manufacturer; no exceptions.

B. Substitutions: See Section 01600 - Product Requirements.

2.02 PAINTS AND COATINGS - GENERAL

A. Paints and Coatings: Ready mixed, unless intended to be a field-catalyzed coating.

1. Provide paints and coatings of a soft paste consistency, capable of being readily and uniformly dispersed to a homogeneous coating, with

good flow and brushing properties, and capable of drying or curing free of streaks or sags.

2. Supply each coating material in quantity required to complete entire project's work from a single production run.

3. Do not reduce, thin, or dilute coatings or add materials to coatings unless such procedure is specifically described in manufacturer's

product instructions.

B. Primers: Where the manufacturer offers options on primers for a particular substrate, use primer categorized as "best" by the manufacturer.

C. Volatile Organic Compound (VOC) Content:

1. Provide coatings that comply with the most stringent requirements specified in the following:

a. 40 CFR 59, Subpart D--National Volatile Organic Compound Emission Standards for Architectural Coatings.

2. Determination of VOC Content: Testing and calculation in accordance with 40 CFR 59, Subpart D (EPA Method 24), exclusive of colorants

added to a tint base and water added at project site; or other method acceptable to authorities having jurisdiction.

2.03 PAINT SYSTEMS - INTERIOR

A. Paint I-OP - All Interior Surfaces Indicated to be Painted, Unless Otherwise Indicated: Including gypsum board, concrete, concrete masonry,

brick, wood, aluminum, and _____.

1. Two top coats and one coat primer.

2. Primer(s): As recommended by manufacturer of top coats.

B. Paint I-OP-MD-DT - Medium Duty Door/Trim: For surfaces subject to frequent contact by occupants, including metals, wood, and ______:

1. Two top coats and one coat primer.

PART 3 EXECUTION

3.01 PREPARATION

A. Clean surfaces thoroughly and correct defects prior to coating application.

B. Prepare surfaces using the methods recommended by the manufacturer for achieving the best result for the substrate under the project

conditions.

C. Remove or mask surface appurtenances, including electrical plates, hardware, light fixture trim, escutcheons, and fittings, prior to preparing

surfaces or finishing.

D. Seal surfaces that might cause bleed through or staining of topcoat.

E. Remove mildew from impervious surfaces by scrubbing with solution of tetra-sodium phosphate and bleach. Rinse with clean water and allow

surface to dry.

F. Concrete and Unit Masonry Surfaces to be Painted: Remove dirt, loose mortar, scale, salt or alkali powder, and other foreign matter. Remove

oil and grease with a solution of tri-sodium phosphate; rinse well and allow to dry. Remove stains caused by weathering of corroding metals

with a solution of sodium metasilicate after thoroughly wetting with water. Allow to dry.

G. Gypsum Board Surfaces to be Painted: Fill minor defects with filler compound. Spot prime defects after repair.

H. Aluminum Surfaces to be Painted: Remove surface contamination by steam or high pressure water. Remove oxidation with acid etch and

solvent washing. Apply etching primer immediately following cleaning.

I. Galvanized Surfaces to be Painted: Remove surface contamination and oils and wash with solvent. Apply coat of etching primer.

J. Corroded Steel and Iron Surfaces to be Painted: Prepare using at least SSPC-SP 2 (hand tool cleaning) or SSPC-SP 3 (power tool cleaning)

followed by SSPC-SP 1 (solvent cleaning).

K. Uncorroded Uncoated Steel and Iron Surfaces to be Painted: Remove grease, mill scale, weld splatter, dirt, and rust. Where heavy coatings of

scale are evident, remove by hand or power tool wire brushing or sandblasting; clean by washing with solvent. Apply a treatment of phosphoric

acid solution, ensuring weld joints, bolts, and nuts are similarly cleaned. Prime paint entire surface; spot prime after repairs.

L. Shop-Primed Steel Surfaces to be Finish Painted: Sand and scrape to remove loose primer and rust. Feather edges to make touch-up patches

inconspicuous. Clean surfaces with solvent. Prime bare steel surfaces. Re-prime entire shop-primed item.

M. Exterior Wood Surfaces to Receive Opaque Finish: Remove dust, grit, and foreign matter. Seal knots, pitch streaks, and sappy sections. Fill

nail holes with tinted exterior calking compound after prime coat has been applied. Back prime concealed surfaces before installation.

3.02 APPLICATION

A. Exterior Wood to Receive Opaque Finish: If final painting must be delayed more than 2 weeks after installation of woodwork, apply primer

within 2 weeks and final coating within 4 weeks.

B. Apply products in accordance with manufacturer's instructions.

C. Do not apply finishes to surfaces that are not dry. Allow applied coats to dry before next coat is applied.

D. Apply each coat to uniform appearance.

E. Sand wood and metal surfaces lightly between coats to achieve required finish.

F. Vacuum clean surfaces of loose particles. Use tack cloth to remove dust and particles just prior to applying next coat.

G. Reinstall electrical cover plates, hardware, light fixture trim, escutcheons, and fittings removed prior to finishing.

END OF SECTION

Page 4: 060 - Procurement & Strategic Sourcing

70'-8"

79'-6"

79'-6"

PLAN KEY NOTES:

(TYPICAL THIS SHEET ONLY)

CORRIDOR ARETO BE NON RATED, WALLS EXTEND 6" ABOVE LAY-IN CEILING, THEY DO

NOT EXTEND TO UNDERSIDE OF DECK.

1 HOUR RATED WALL CONSTRUCTION

CODE STUDY COMMENTS

BUILDING IS NOT FULLY SUPPRESSED, NO SUPPRESSION IS PRESENT IN AREA OF WORK .

IN THE AREA OF SCOPE, WORK BEING PREFORMED DOES NOT CHANGE USE, OCCUPANCY

LOAD OR ALTER PATHS OF EGRESS. ALL EXISTING FIRE PROTECTION SYSTEMS ARE TO

RE-INSTALLED AFTER CONSTRUCTION TO MAINTAIN CONTINUITY AND INTENT OF

ORIGINAL DESIGN. RELOCATION OF EXIST. FIXTURES MAY BE REQUIRED DURING FINAL

DESIGN.

1

FLOOR PLAN

SCALE: 3/32"=1'-0"

N

AREA OF SCOPE

SCOPE OF THIS PROJECT INCLUDES THE RENOVATION OF THE EXISTING BREAK

ROOM TO PROVIDE ARCHITECTURAL RENOVATIONS, MECHANICAL/ELECTRICAL

UPGRADES AND NEW INTERIOR FINISHES IN THE ARE HATCHED. PLEASE SEE

COMPLETE ARCHITECTURAL, FINISHES AND MECHANICAL/ELECTRICAL SHEETS

FOR DETAILS OF WORK.

1

EXIT

EXIT

EXIT

LEGEND

EXISTING NOT UPGRADED; ALL NEW WORK

TO CONFORM TO:

2 HOUR FIRE RATED WALL

90 MINUTE OPENINGS

1 HOUR FIRE RATED WALL

60 MINUTE OPENINGS

45 MINUTE DOORS

1 HOUR FIRE RATED WALL

20 MINUTE OPENINGS

OCCUPANT LOAD

TOTAL EXIT LOAD

2 HOUR FIRE RATED WALLS

90 MINUTE OPENINGS

1 HOUR RATED CORRIDOR

SMOKE BARRIER

SMOKE TIGHT OPENINGS

APPROVED STAIRWAY

1 HOUR RATED WALLS

60 MINUTE OPENINGS

1 HOUR RATED FIRE BARRIER

& AUTOMATIC EXTINGUISHING

SYSTEMS

45 MINUTE DOORS

DISTANCE TO EXIT

X

ROOM

NAME

X

PARTIAL FLOOR PLAN

SCALE: 1/8"=1'-0"

N

EXIT

EXIT

2

2

2

PARTIAL FLOOR PLAN

SCALE: 1/8"=1'-0"

N

2

Page 5: 060 - Procurement & Strategic Sourcing

S

S

S

7'-4"

9'-0"

ETR

ETR

1. ALL DEMOLITION WORK REQUIRED IS NOT NECESSARILY LIMITED TO WHAT IS SHOWN ON

THE DEMOLITION PLANS. THE INTENT IS TO REMOVE ALL MECHANICAL, ELECTRICAL, AND

ARCHITECTURAL ITEMS AS REQUIRED TO FACILITATE NEW CONSTRUCTION.

2. COORDINATE SCOPE AND EXTENT OF DEMOLITION WORK WITH NEW WORK PLANS AND

DETAILS.

3. ALL WALLS, DOORS, FRAMES, AND RELATED HARDWARE ASSEMBLIES DESIGNATED AS "TO

BE REMOVED" (SHOWN AS DASHED LINES) SHALL BE COMPLETELY REMOVED AND

DISPOSED OF AS DESIGNATED BY OWNER/TENANT. ALL EXISTING WALLS NOT

DESIGNATED FOR DEMOLITION SHALL BE PROTECTED FROM DAMAGE AND REMAIN "AS-IS".

4. ALL EQUIPMENT, DOORS, FRAMES, RELATED HARDWARE, AND DESIGNATED ITEMS TO BE

SALVAGED SHALL BE REMOVED, PROTECTED FROM DAMAGE, AND STORED FOR REUSE.

5. CLEAN AND REPAIR ALL EXISTING FLOOR FINISHES AS NECESSARY.

6. ALL DEMOLITION WORK SHALL BE PERFORMED IN A NEAT AND WORKMANLIKE MANNER.

ALL SURFACES ADJACENT TO AND ABUTTING TO THOSE DESIGNATED "TO BE REMOVED"

SHALL BE LEFT WITH A SMOOTH AND FLUSH APPEARANCE.

7. THE CONTRACTOR SHALL EXERCISE ALL REQUISITE CARE NECESSARY TO ENSURE THAT

ALL EQUIPMENT, MATERIALS, FINISHES AND ASSEMBLIES WHICH ARE NOT BEING

REMOVED ARE PROTECTED FROM DAMAGE DURING DEMOLITION AND SUBSEQUENT

CONSTRUCTION OPERATIONS.

8. REFER TO MECHANICAL AND ELECTRICAL DEMOLITION DRAWINGS AND SPECIFICATIONS

FOR ADDITIONAL DEMOLITION INFORMATION.

9. GENERAL PRECAUTIONS SHALL BE TAKEN AS NECESSARY TO HOLD ALL DISRUPTION,

DUST, DIRT, NOISE, AND DEBRIS TO A MINIMUM.

10. THE CONTRACTOR SHALL COORDINATE DEMOLITION WORK WITH OWNER TO ENSURE

THAT IMPACTS ON THE BALANCE OF THE BUILDING ARE HELD TO A MINIMUM.

11. PREPARE ALL SURFACES TO RECEIVE THE NEW WORK AND FINISHES OF THE CONTRACT.

12. THE CONTRACTOR SHALL DESIGN, PROVIDE, INSTALL AND MAINTAIN ANY AND ALL

TEMPORARY BRACING AS REQUIRED TO ENSURE THE STABILITY OF THE BUILDING

ASSEMBLY AND/OR ANY SYSTEMS AND/OR SUB-ASSEMBLIES AND/OR SYSTEMS

APPURTENANT THERETO UNTIL SAID ASSEMBLY AND/OR SUB-ASSSEMBLIES ARE

COMPLETE, SELF-SUPPORTING AND/OR STABLE.

GENERAL DEMOLITION PLAN NOTES:

DEMOLITION PLAN KEY NOTES:

(TYPICAL THIS SHEET ONLY)

REMOVE EXISTING FLOORING AND BASE COMPLETE

REMOVE EXISTING MILL WORK, PREP PLUMBING AND SLAB AS REQ'D TO ACCOMMODATE

NEW WORK

REMOVE DOOR, FRAME AND HARDWARE COMPLETE

REMOVE PORTION OF WALL ABOVE 3'-6", KNEE WALL TO REMAIN, REWORK EXISTING

ELEC. AND DATA AS REQ'D TO ACCOMMODATE NEW WALL CONFIGURATION.

LAY-IN CEILING AND PADS TO REMAIN

NOT USED

REMOVE EXIST. LIGHT FIXTURE

REMOVE LAY-IN CEILING/PADS COMPLETE

LINE OF TERMINATION OF NEW LAY-IN CEILING

REMOVE DIFFUSER/SUPPLY

EXISTING FIRE STROBE TO REMAIN

REMOVE EXISTING COLUMN CLADDING TO EXPOSED STEEL COLUMN.

REMOVE PORTION OF WALL, PROVIDE LINTEL AS REQ'D FOR NEW DOOR OPENING

REMOVE SURFACE MOUNTED FIXTURE

REMOVE SURFACE MOUNTED FIXTURE AND DISCONNECT, PROVIDE WHITE BLANK COVER

PLATE AT EXISTING J-BOX TO REMAIN

LINE DEFINES GENERAL AREA OF WORK. ADDITIONAL WORK OR

INTERACTION WITH ADJACENT AREAS OUTSIDE BOUNDARY MAY

BE REQUIRED. LINE SHOULD NOT BE USED AS A CONSTRUCTION

SCOPE BOUNDARY.

D1

D2

WALL TO REMAIN

WALL TO BE REMOVED

DOOR TO REMAIN

DOOR, FRAME AND HARDWARE TO BE REMOVED UNLESS NOTED

OTHERWISE

DESIGNATED ITEM TO REMAIN

DESIGNATED ITEM TO BE REMOVED

DEMOLITION KEY:

7'-4"

D1

D1

D1

D1

D2

D3

D3

D3

D4

D5

D4

D4

D5

D5

D5

D5

D8

D6

D7

D7

D7

D7D7

D7 D7D7 D7

D7D7

D7D7

D7

D7

D7

D7

D7

D7

D7

D7

D7

D7

D7

D7

D7

D8

D8

D8

D9

D9

D10

D10D10

D10

D10

D11

D11

DEMOLITION 1ST FLOOR PLAN

SCALE: 1/8"=1'-0"

N

DEMOLITION 1ST FLOOR CELING PLAN

SCALE: 1/8"=1'-0"

N

D7

D7

D7

D7

D7

D7

D12

D12

D13

D13

D8

D13

D12

DEMOLITION 2ND FLOOR CELING PLAN

SCALE: 1/8"=1'-0"

N

D14

D15

D14

D14

D14

D14

D15

D16 D16

D16

D16

D9

D7

D7

D7

D7

D10

D10

D10

D10

D12

D9

D1

Page 6: 060 - Procurement & Strategic Sourcing

15'-3" 1'-6" 5'-7"5'-0"

5'-0

"1

3'-1

1"

18

'-0

"

26'-2"

17

'-8

"

15'-3" 1'-6" 5'-7"5'-0"

5'-0

"1

3'-1

1"

18

'-0

"

26'-2"

17

'-8

"

- 5/8" THK GYP. BD.

- MTL STUDS @ 16" O.C.

W/ SOUND BATT INSUL.

- 5/8" THK GYP. BD.

(1HR RATED ASSEMBLY

UL# U465)

(TYPICAL UNLESS

NOTED OTHERWISE)

- 5/8" THK GYP. BD.

- MTL STUDS @ 16" O.C. W/

BATT INSUL.

5/8"

SEE PLAN

WALL TYPE SCHEDULE

EX

TE

RIO

R W

AL

L

FR

AM

IN

G

NOTES:

* ALL WALL TYPES EXTEND FROM FLOOR TO UNDERSIDE ROOF/FLOOR DECK UNLESS NOTED OTHERWISE.

* REFER TO FLOOR PLAN FOR WALL THICKNESS.

* REFER TO CODE PLAN FOR WALL RATING REQUIREMENTS.

- SIMILAR TO TYPE 1A

EXCEPT LESS BATT

INSUL.

- 5/8" THK GYP. BD.

- 7/8" MTL HATCHANNEL

NO INSUL.

5/8"

SEE PLAN

5/8"

SEE PLAN

5/8"

1A 2B 3

1B

1. THIS DRAWING IS DIAGRAMMATIC AND SHOULD BE USED TO DETERMINE THE DESIGN

INTENT. THE CONTRACTOR IS RESPONSIBLE FOR THE COMPLETE SET OF WORK AS

INDICATED AND SHALL FIELD VERIFY ALL WORK, COORDINATE ALL DRAWINGS / NEW WORK

AND SHALL NOTIFY ARCHITECT IMMEDIATELY OF ANY DISCREPANCIES IN THE DOCUMENTS

BEFORE PROCEEDING. FAILURE TO DO SO WILL RESULT IN THE CONTRACTOR TAKING

FULL RESPONSIBILITY AND LIABILITY FOR SAID DISCREPANCIES.

2. ALL DIMENSIONS ARE SHOWN FROM FINISH FACE TO FINISH FACE OF PARTITION UNLESS

OTHERWISE NOTED.

3. WALL THICKNESS' ARE NOMINAL NOT ACTUAL DIMENSIONS. SEE WALL SCHEDULE FOR

ACTUAL DIMENSIONS.

4. ALL WOOD, INCLUDING BLOCKING, USED ON THE PROJECT SHALL BE FIRE RETARDANT

TREATED.

5. ALL WORK SHALL BE DONE IN ACCORDANCE WITH ALL LOCAL, STATE, COUNTY CODE

REGULATIONS, O.S.H.A., AND THE AMERICAN WITH DISABILITIES ACT (ADA). REFER TO THE

CODE PLAN FOR MORE INFORMATION.

6. PROVIDE POSITIVE SLOPE TO ALL FLOOR DRAINS WHILE KEEPING FLOOR LEVEL AT WALL

BASE CONDITION.

7. PROVIDE TRANSITION STRIPS AT EACH CHANGE IN FLOOR FINISH MATERIALS.

8. PAINT, PATCH AND REPAIR THE FOLLOWING TO MATCH EXISTING MATERIALS: FLOOR,

WALL, AND CEILING SURFACES AS REQUIRED ADJACENT TO AREAS BEING DEMOLISHED.

REFER TO DEMOLITION DRAWINGS FOR MORE INFORMATION.

9. REINFORCE WALL AND PROVIDE BLOCKING AS REQUIRED TO SUPPORT WALL CABINETS

AND COUNTERTOPS.

10. THE CONTRACTOR SHALL PROVIDE AND INSTALL WALL REINFORCING FOR INSTALLATION

OF ACCESSORIES, COAT RACKS, CHART RACKS, CASEWORK, AND OTHER WALL MOUNTED

ITEMS.

11. CLEAN AND REPAIR ALL EXISTING FLOOR FINISHES AS NECESSARY.

12. ALL EXPOSED PIPES, DUCTS, AND CONDUIT TO BE PAINTED TO MATCH EXISTING.

13. PROVIDE CONTROL JOINTS IN GYPSUM BOARD PARTITIONS AT 30'-0" O.C. MAXIMUM AND AS

INDICATED IN THE CONTRACT DOCUMENTS.

14. COORDINATE WITH OWNER'S EQUIPMENT SUPPLIER FOR INSTALLATION REQUIREMENTS /

LOCATIONS OF FLOOR / WALL / CEILING MOUNTED ITEMS; IE. CAMERAS, TV'S, SPEAKERS,

SENSORS, SECURITY WIRING, VAULTS, ATM'S.

15. CONTRACTOR SHALL CONDUCT A ROUGH ELECTRICAL INSPECTION WITH OWNER, PRIOR

TO ENCLOSING WALLS, FOR THE PURPOSE OF CONFIRMING ALL J-BOX LOCATIONS FOR

POWER, DATA, VOICE, SWITCH, THERMOSTAT, ETC.

16. CONTRACTOR TO FILL ANY AND ALL EQUIPMENT PENETRATIONS OR DEPRESSIONS INTO

OR THROUGH THE EXISTING SLAB THAT WILL NOT BE UTILIZED TO FEED NEW EQUIPMENT

(I.E. ABANDONED FLOOR CORES, IMPRESSION FROM PREVIOUS EQUIPMENT FLOOR PLATE

REMOVAL). PENETRATIONS SHALL BE FILLED WITH NON-SHRINK GROUT. THE SIDES OF

ANY EXISTING OPENINGS SHALL BE MODIFIED/TAPERED SO THAT THEY ARE WIDER AT THE

TOP THAN AT THE BOTTOM. FOR LARGE OPENINGS, PROVIDE ONE (1) #5 BAR 2" UP FROM

BOTTOM OF HOLE.

17. A TACTILE SIGN STATING 'EXIT' AND COMPLYING WITH ICC-A117.1 SHALL BE PROVIDED

ADJACENT TO EACH DOOR TO AN 'AREA OF REFUGE', AN EXTERIOR AREA FOR ASSISTED

RESCUE, AN EXIT STAIRWAY, AN EXIT RAMP, AN EXIT PASSAGEWAY, AND THE EXIT

DISCHARGE.

18. PROVIDE PERMANENT 2-INCH HIGH LETTERING MARKING AND IDENTIFICATION AT ALL FIRE

WALLS, FIRE BARRIERS, FIRE PARTITIONS, SMOKE BARRIERS, SMOKE PARTITIONS OR ANY

OTHER WALL REQUIRED TO HAVE PROTECTED OPENINGS OR PENETRATIONS AT 30 FEET

MAXIMUM HORIZONTAL INTERVALS, MINIMUM 2 LOCATIONS EACH WALL, IN ACCESSIBLE

CONCEALED FLOOR, FLOOR-CEILING, OR ATTIC SPACES PER CODE.

GENERAL FLOOR PLAN NOTES:

FLOOR PLAN KEY NOTES:

(TYPICAL THIS SHEET ONLY)

NEW BUTT-GLAZED GLASS ON 3'-6" KNEE WALL, PROVIDE DATA AND

POWER AS REQ'D

NEW MILL WORK, PROVIDE PLUMBING TO ACCOMMODATE NEW SINK

MILLWORK PENINSULA, AT 42" AFF. PROVIDE PEDESTAL BASE SUPPORT

REFRIGERATOR BY OWNER

PROVIDE MILL WORK ABOVE COUNTER TOP FOR DOUBLE STACKED

MICROWAVE OVENS

36" ROUND TABLE AND CHAIRS (FOR REFERENCE ONLY,

ALL FURNITURE BY OWNER)

VENDING MACHINES (BY OWNER VENDOR)

NOT USED

PROVIDE NEW RUBBER FLOORING BY NORA AND RUBBER WALL BASE IN

CORRIDOR AND AT RAMP, COLOR TO BE SELECTED BY OWNER

FURR OUT WALL WITH 3/4" GYP. BD ON METAL HAT CHANNELS

PROVIDE RESILIENT PLANK FLOORING

BANQUETTE SEATING WITH CHAIRS AND 24x60 TABLE (BY OWNER)

SEE ELEVATION 4/A1.1 FOR TV. WALL RECESS DIMENSIONS

LINE DEFINES GENERAL AREA OF WORK. ADDITIONAL WORK OR

INTERACTION WITH ADJACENT AREAS OUTSIDE BOUNDARY MAY

BE REQUIRED. LINE SHOULD NOT BE USED AS A CONSTRUCTION

SCOPE BOUNDARY.

1

2

ARCHITECTURAL FLOOR PLAN

SCALE: 1/8"=1'-0"

N

LOCATOR PLAN

NOT TO SCALE

N

PROJECT AREA

GENERAL FLOOR PLAN NOTES CON'T:

PARTIALL FLOOR PLAN

SCALE: 1/4"=1'-0"

1

1

2

3

3

4

4

5

5

66

66

7

7

8

8

8

9

9

9

10

10

11

11

7

7

7

4

-

1

2

A-6.1

6

A-6.1

5

A-6.1

128.1A

1B

CORRIDOR

128.1

128.1B

128.1G

EXIST

128.1H

BREAK

ROOM

128

VENDING

122.0

CORRIDOR

EXIST

128A

CORRIDOR

128.1

CORRIDOR

128.1

CORRIDOR

128.1

VENDING

122.0

BREAK

ROOM

128

1

A-1.1

1

A-1.1

1B 1B

2B

2B

3

1A

1A

3

12

1212

128.1C

128.1D

128.1E

128.1F

2

A-6.1

3

A-6.1

EXIST

13

14

14

10

11

Page 7: 060 - Procurement & Strategic Sourcing

STEEL RUNNER FASTENED

TO STRUCTURE ABOVE

5/8" GYP. BOARD - EXTEND 8"

ABOVE ACOUSTIC CEILING TILE

ACOUSTIC CEILING TILE AND

TEE

REFER TO RCP

CORNER REINFORCEMENT

MIN. 3 5/8" STEEL STUD @

24" O.C.

RE

FE

R T

O R

CP

FO

R H

EIG

HT

A

.F

.F

.

PROVIDE DIAGONAL

BRACING 48" OC MAX.

8"; T

YP

S

S

S

1. SWITCH SYMBOL INDICATES THE LOCATION FOR SWITCHING ALL FIXTURES WITHIN THAT

ROOM UNLESS NOTED OTHERWISE. REFER TO ELECTRICAL DRAWINGS FOR FURTHER

INFORMATION AS REQUIRED.

2. CONTRACTOR TO CENTER ALL CEILING MOUNTED ITEMS (i.e.. RECESSED LIGHT FIXTURES,

SMOKE DETECTORS, FIRE SUPPRESSION HEADS) WITHIN THE ASSOCIATED CEILING TILE

AS SHOWN. COORDINATE FINAL LOCATION WITH THE APPROPRIATE MECHANICAL,

ELECTRICAL, FIRE ALARM, AND FIRE SUPPRESSION DRAWINGS AS REQUIRED.

3. REFER TO WALL TYPES FOR WALLS THAT PENETRATE CEILINGS.

4. REFER TO MECHANICAL HVAC PLANS FOR DIFFUSER / GRILLE SIZES.

5. FOR LIGHT FIXTURE TYPES SEE ELECTRICAL LIGHTING PLANS.

6. REFER TO DIMENSIONS ON REFLECTED CEILING PLAN TO LOCATE / LAYOUT CEILING GRID

AND LIGHT FIXTURES.

7. ACCESS PANELS TO BE INDEPENDENTLY MOUNTED, DO NOT SUPPORT ON CEILING GRID.

COORDINATE SIZE, QUANTITY AND LOCATIONS WITH ARCHITECTURAL AND MECHANICAL

DRAWINGS.

GENERAL REFLECTED CEILING PLAN NOTES:

REFLECTED CEILING PLAN KEY NOTES:

(TYPICAL THIS SHEET ONLY)

EXIST. CEILING TO REMAIN

NEW 2X2 GRID, REWORK EXIST. HVAC SUPPLY AND DIFFUSERS VIF EXISTING LOCATIONS,

CEILING HEIGHT TO REMAIN CONSISTENT AFF AS FINISH FLOOR HEIGHT VARIES.

NEW 2X4 LED FIXTURE BY LITHONIA

NEW 1X4 LED FIXTURE BY LITHONIA IN EXISTING CEILING GRID, REPAIR DAMAGED TILES

AS REQ'D.

6" CAN LIGHTS,

NEW LINEAR DIFFUSERS

NEW PENDANT LIGHTS OVER NEW ISLAND

NOT USED

NEW SURFACE MOUNTED LED LIGHTS

REPAINT CEILING,ACCESS PANELS AND DIFFUSERS/AIR RETURNS TO MATCH EXISTING

ADJACENT

LINE DEFINES GENERAL AREA OF WORK. ADDITIONAL WORK OR INTERACTION WITH

ADJACENT AREAS OUTSIDE BOUNDARY MAY BE REQUIRED. LINE SHOULD NOT BE USED

AS A CONSTRUCTION SCOPE BOUNDARY.

NEW GYPSUM BOARD SOFFIT TO BE PAINTED (PT-5)

A

B

ACOUSTIC CEILING TILE SYSTEM PER

SPECIFICATION

1'X4' LED LIGHT FIXTURE

2'X4' LED LIGHT FIXTURE

2'X2 'LED LIGHT FIXTURE

2'X4' LED NIGHT LIGHT FIXTURE, SEE

ELECTRICAL

SUPPLY AIR DIFFUSER

RETURN AIR GRILL

GYPSUM BOARD CEILING AND/OR SOFFIT

RECESSED DOWNLIGHT FIXTURE

EMERGENCY LIGHT FIXTURE W/ BATTERY

SUPPLY

ELEVATION ABOVE FINISHED FLOOR

SMOKE DETECTOR

WALL WASHING LIGHT FIXTURE

UNDER CABINET LIGHT FIXTURE

WALL SWITCH

FIRE SUPPRESSION HEAD

SPEAKER

S

2'X4' LEDLIGHT FIXTURE WITH 'XX' CELL,

DEEP-CELL PARABOLIC DIFFUSER

2'X4' LED DIRECT/INDIRECT LIGHT FIXTURE

S

EXIT LIGHT (SHADING INDICATES LIGHTED

FACE)

REFLECTED CEILING LEGEND

DESCRIPTIONSYMBOL

SWALL SCONCE FIXTURE

EXISTING FIXTURE TO REMAINE

EXISTING FIXTURE TO BE RELOCATEDR

DESCRIPTIONSYMBOL DESCRIPTIONSYMBOL

EXHAUST AIR GRILL

HEIGHT

REFLECTED CEILING PLAN

SCALE: 1/4"=1'-0"

N

8'-4"

8'-0"

9-6"

ETR

ETR

8'-6"

ETR

A

A

A

A

A

A

A

A

A

A

A

A

A

A

B

B

C

CCCC

C

C

C

C

C

C

C

C

D

D

D

D

D

D

D

D

D

D

D

B

E

E

TYP.

E

TYP.

F

F

F

G

G

H

7'-8"

9-6"

8'-0"

7'-4"

7'-4"

ETR

ETR

8'-4"

BRACED SOFFIT DETAILX

TYP.

SCALE: 1 1/2"=1'-0"

2ND FLOOR CELING PLAN

SCALE: 1/8"=1'-0"

N

J

J

J

J

J

K

K

L

L

L

M

M

M

M

M

C

C

C

A

B

Page 8: 060 - Procurement & Strategic Sourcing

2"

1'-8" 3'-4"

2'-1

0"

3'-6

"

9"

4"

BASE AS SCHEDULED

GYP. BOARD SOFFIT

COUNTERTOP AND

BACK SPLASH

P.LAM FILLER PANEL

WALL BASE ON TOE

KICK AS SCHEDULED

P.LAM BASE CABINETS

1

A7.1

OPEN TO

BEYOND

1'-6

"

3'-6

"

BASE AS SCHEDULED

BANQUET BOOTH

SEATING BY OTHERS

GYP. BOARD SOFFIT

3'-0

"4

'-4

"

4'-4"

PROVIDE 4" GYP. BD.

RECESS FOR TV.

(TV BY OWNER)

OPEN TO

BEYOND

OPEN TO

BEYOND

OPEN TO

BEYOND

BASE AS SCHEDULED

GYP. BOARD SOFFIT

1'-4"

4"

2'-1

0"

2'-4"3'-0"3'-2 1/2" 1'-5"1'-5" 1'-5" 1'-5"

2'-1

0"

1'-8"

2'-9

1

/2

"

1"

1 1/2"

WALL BASE ON TOE

KICK AS SCHEDULED

GYP. BOARD SOFFIT

COUNTERTOP AND

BACK SPLASH

FULL HEIGHT WALL

TILE

P.LAM BASE

CABINETS

P.LAM MICROWAVE

SHELVES

P.LAM FILLER

PANEL

1

A7.1

2

A7.1

3

A7.1

VENDING MACHINE

BY OWNER

PROVIDE NEW

ELECTRICAL

OUTLET FOR

EACH MACH.

TYP.

REFRIGERATOR

BY OWNER

ELECTRICAL OUTLET,

TYP.

3'-6

"

BRUSHED STAINLESS

STEEL SUPPORT

BRACKET

GYP. BOARD SOFFIT

BARTOP

PENDANT LIGHT

FIXTURES

4

A7.1

OPEN TO

BEYOND

OPEN TO

BEYOND

OPEN TO

BEYOND

BASE AS SCHEDULED

GYP. BOARD SOFFIT

3'-6

"7

'-8

"

INTERIOR ELEVATION1

A1.1

SCALE: 1/4" = 1'-0" #128 BREAK ROOM / # 128.1 CORRIDOR

INTERIOR ELEVATION2

A1.1

SCALE: 1/4" = 1'-0" #122.0 VENDING / #128 BREAK ROOM

INTERIOR ELEVATION3

A1.1

SCALE: 1/4" = 1'-0" #128 BREAK ROOM

INTERIOR ELEVATION4

A1.1

SCALE: 1/4" = 1'-0" #128 BREAK ROOM

INTERIOR ELEVATION5

A1.1

SCALE: 1/4" = 1'-0" # 128.1 CORRIDOR

INTERIOR ELEVATION6

A1.1

SCALE: 1/4" = 1'-0" # 128.1 CORRIDOR

Page 9: 060 - Procurement & Strategic Sourcing

4"

2'-1"

SE

E E

LE

VA

TIO

NS

FINISHED FLOOR AS SCHEDULED

BASE AS SCHEDULED ON MDF

TOE KICK

P.LAM ON 3/4" MDF DOOR

P.LAM ON 3/4" ADJUSTABLE MDF

SHELF

1"

P.LAM ON MDF

BASE CABINET

P.LAM ON 3/4" MDF DRAWER

4" DOOR / DRAWER PULL AS

SPECIFIED, TYPICAL

CONTINUOUS

SEALANT JOINT

1/2" SOLID SURFACE

COUNTERTOP WITH APPLIED

BACKSPLASH & SIDESPLASH

1-1/2" SOLID SURFACE EDGE

4"

2"

4"

2'-1"

SE

E E

LE

VA

TIO

NS

FINISHED FLOOR AS SCHEDULED

BASE AS SCHEDULED ON MDF

TOE KICK

P.LAM ON 3/4" MDF DOOR

1"

P.LAM ON MDF

BASE CABINET

P.LAM ON 3/4" FIXED PANEL

4" DOOR / DRAWER PULL AS

SPECIFIED, TYPICAL

CONTINUOUS

SEALANT JOINT

1-1/2" SOLID SURFACE EDGE4

"

UNDERMOUNT SINK AND FAUCET

ASSEMBLY AS SPECIFIED

3"

MAX.

1/2" SOLID

SURFACE

COUNTERTOP

WITH APPLIED

BACKSPLASH &

SIDESPLASH

CONTINUOUS SEALANT JOINT

2"

1'-6"

1'-4

" C

LE

AR

2'-1

0" H

OL

D

MICROWAVE

ELECTRICAL

OUTLET, EXTEND

BOX FROM WALL

TO MOUNT COVER

PLATE ON

MILLWORK REAR

PANEL, CABINET

AND ELECTRICAL

SUBCONTRACTORS

SHALL

COORDINATE

WORK

P.LAM ON 3/4" MDF MICROWAVE

SHELF. COORDINATE OPENING

DIMENSIONS WITH EQUIPMENT TO

BE PROVIDED BY OWNER

MICROWAVE

1'-4

" C

LE

AR

P.LAM ON 3/4" MDF MICROWAVE

SHELF. COORDINATE OPENING

DIMENSIONS WITH EQUIPMENT TO

BE PROVIDED BY OWNER

CONTINUOUS ALUMINUM

SUPPORT ANGLE WHERE

COUNTER TOP MEETS WALL

CONSTRUCTION

2-1/2" SOLID SURFACE EDGE

2'-0"

3'-6

"

4"

8" Ø STAINLESS STEEL BASE

ADJACENT CABINET

W/ SOLID SURFACE

COUNTER TOP

BASE

1. REFER TO ELEVATIONS FOR SPECIFIC DOOR AND DRAWER CONFIGURATIONS AND

CABINET HEIGHTS.

2. CONTRACTOR SHALL COORDINATE INSTALLATION OF BLOCKING IN STUD CAVITY AS

REQUIRED FOR CABINET INSTALLATION.

3. PLASTIC LAMINATE FINISH SHOULD BE CONSIDERED TYPICAL AT ALL SURFACES OF ALL

COMPONENTS EXPOSED IN FINISHED INSTALLATION (WITH THE EXCEPTION OF ALL

DOOR AND DRAWER EDGES AND ALL SIDES OF ADJUSTABLE SHELVES, WHICH SHALL

HAVE 3mm PVC EDGE BANDING TO MATCH THE LAMINATE, EXCEPT AT LOCATIONS OF

INSTALLED QUARTZ). INTERIOR CABINET SURFACES AND SHELVES WITHIN ENCLOSED

CABINETS SHALL BE FINISHED WITH WHITE MELAMINE.

4. STANDING AND RUNNING TRIM RAILS TO RECEIVE STAINED FINISH SHALL COMPLY

WITH AWI (ARCHITECTURAL WOODWORK INSTITUTE) SECTION 300.

5. WOOD CABINETS (CASEWORK) TO RECEIVE STAINED FINISH SHALL COMPLY WITH AWI

SECTION 400 AND ITS DIVISION 400A "WOOD CABINETS", GRADE: PREMIUM.

6. PROVIDE HIGH PRESSURE LAMINATE AS INDICATED IN FINISH SCHEDULE.

7. COUNTERTOPS SHALL COMPLY WITH AWI SECTION 400 AND ITS DIVISION 400C, GRADE:

PREMIUM.

8. MILLWORK SHALL BE FACTORY FABRICATED AS FAR AS POSSIBLE, AND DELIVERED TO

THE SITE, READY FOR INSTALLATION AND HOOKUP TO ELECTRICAL AND MECHANICAL

ITEMS.

9. CABINET BASES SHALL BE AN INTEGRAL PART OF THE CABINET CONSTRUCTION. PRIME

PAINT FACE OF BASE IN SHOP WHERE VINYL OR RUBBER BASE IS INDICATED. WHERE

NO BASE IS INDICATED PROVIDE P.LAM TO MATCH CABINET.

10. PROVIDE BACKING SHEET ON UNDERSIDE OF PLASTIC LAMINATE SURFACED SHELF

AND ON REAR FACE OF ANY PLASTIC LAMINATE FACED ITEMS, WHERE STANDARD FACE

SHEET IS NOT INDICATED OR EXPOSED TO VIEW.

11. SCRIBE CABINETRY HORIZONTAL AND VERTICAL JOINTS TO WALL. FIELD CUT FOR

CAREFUL FIT WITH MAXIMUM 1/16" GAP. PROVIDE CONTINUOUS CLEAR SEALANT JOINT.

12. CORE MATERIAL FOR CABINETS SHALL BE 3/4" THICK MDF (WITH THE EXCEPTION OF

COUNTERTOPS CONTAINING SINKS, WINDOW SILLS, AND OTHER WET LOCATIONS,

WHICH SHALL BE WATER RESISTANT MDF).

13. ADHESIVE FOR LAMINATING SHALL BE A CONTACT ADHESIVE PER MANUFACTURER'S

STANDARD RECOMMENDATIONS.

14. ALL EXPOSED EDGES OF MILLWORK COUNTERTOPS, WORKSURFACES, LOCKER

BENCHES, OR OTHER MILLWORK ITEMS SHALL BE FABRICATED WITH A MINIMUM 1 INCH

RADIUS (NO SQUARE EDGES).

15. AT ALL ADA SINK LOCATIONS, THE FRONT OF LAVATORIES AND SINKS SHALL BE 34

INCHES MAXIMUM ABOVE THE FLOOR, MEASURED TO THE HIGHER OF THE RIM OR

COUNTER SURFACE.

GENERAL MILLWORK NOTES:

MILLWORK SECTION1

A6.1

SCALE: 1"=1'-0"

MILLWORK SECTION2

A6.1

SCALE: 1"=1'-0"

MILLWORK SECTION3

A6.1

SCALE: 1"=1'-0"

MILLWORK SECTION4

A6.1

SCALE: 1"=1'-0"

Page 10: 060 - Procurement & Strategic Sourcing

"F"

AS SCHED

2" 2"

2"

FRAME TYPESDOOR TYPES

"1"

AS

S

CH

ED

"N"

43

" M

AX

8" 3"

FINISH FLOOR LINE - SEE FINISH

SCHEDULE

BASE AS SCHEDULED

FLOOR ANCHOR - SECURE TO FRAME

AND FLOOR

SEALANT BEAD

PROVIDE AND INSTALL THREE ANCHORS

PER JAMB AT HINGE AND STRIKE LEVELS

- TYPICAL

5/8" GYPSUM BOARD BOTH SIDES OF

METAL STUDS

3 5/8" CRIPPLE STUD - 1/2" MIN.

CLEARANCE BETWEEN ADJACENT STUD

DOOR FRAME

3 5/8" METAL STUDS

CONTINUOUS METAL RUNNER

CONTINUE TO BOTTOM OF STRUCTURE

6" HEADER STUD (TYPICAL FOR LOAD

BEARING PARTITIONS; 4" FRAMING

HEADER FOR NON LOAD BEARING

APPLICATIONS)

1/4" GYPSUM BOARD CONTROL JOINT

TYP. AT BOTH JAMBS - CENTER

BETWEEN JAMB AND CRIPPLE STUDS

AND CONTINUE TO TOP OF WALL

METAL RUNNER

(1) LAYER GYP BD ON

METAL STUDS

METAL CHANNEL

(CEILING TRACK)

2 3

/4

"

ROOF STRUCTURE

ABOVE

DEFLECTION ALLOWANCE

SHOWN IS FOR NO LIVE LOAD

ON ROOF

REFER TO SPECS FOR GA OF

STUDS AND ACCESSORIES - DO

NOT SECURE GYP BD TO

TRACK OR RUNNER

SPRAY ON ELASTIC FIREPROOF

JOINT COATING

L4" x 4" x 10GA CONT'S W/. 10GA

PL @ 4'-0" O.C.

HOLLOW METAL JAMB BEYOND

HOLLOW METAL FRAME W/ STEEL

STUD ANCHORS AS REQUIRED BY

MANUFACTURER

CONTINUOUS SEALANT ENTIRE

PERIMETER OF FRAME, BOTH

SIDES

DOUBLE 6" METAL STUD HEADER

5/8" GYP. BD. BOTH SIDES 3

5/8" METAL STUDS @ 16" O.C.

DO

OR

O

PE

NIN

G H

EIG

HT

HEAD

WOOD DOOR

4 7/8"

2"

DO

OR

W

ID

TH

JAMB

4 7/8"

LINE OF ADJ.

PARTITION

4"

2"

CONTINUOUS ACOUSTIC SEALANT

ENTIRE PERIMETER OF WALL

CONSTRUCTION - SET GYPSUM

BOARD IN PLACE AFTER SEALANT

HAS BEEN APPLIED.

RESILIANT COVED BASE

AS SCHEDULED.

5/8" GYPSUM BOARD

STRAIGHT BASE AS SCHEDULED

CONTINUOUS ACOUSTIC SEALANT

ENTIRE PERIMETER OF WALL

CONSTRUCTION - SET GYPSUM

BOARD IN PLACE AFTER SEALANT

HAS BEEN APPLIED

5/8" GYPSUM BOARD

DOOR SCHEDULE

NUMBER ROOM NAME

HARDWARE

DOOR SIZE

SET

LABEL

FRAMEDOOR

MAT'L.

THRESHOLD

FINISH TYPE

TYPE

REMARKS

MAT'L. TYPEFINISH

SET #1

HARDWARE SCHEDULE

1 1/2 PAIR HINGES

1 EXIT HANDLESET

1 CLOSER

REMARKS:

1. PROVIDE CLOSER.

2. TIE HOLD OPEN IN TO BUILDING FIRE MONITORING SYSTEM

GENERAL NOTES:

A. ALL DOOR FRAMES IN MASONRY ASSEMBLIES EXCEEDING 3'-6" IN WIDTH SHALL BE GROUTED SOLID FOR RIGIDITY.

B. HARDWARE ON ALL EXIT DOORS SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY, SPECIAL KNOWLEDGE, OR EFFORT. ALL

DESIGNATED EXIT DOORS SHALL BE NON-LOCKING AGAINST EGRESS.

C. ALL THUMB LATCH LOCKING DEVICES ON MEANS OF EGRESS DOORS SHALL BE ACTIVATED BY NO MORE THAN ONE-HALF (1/2) TURN.

D. ALL DOOR HARDWARE SHALL BE US26D DULL CHROME FINISH AND BE IN COMPLIANCE WITH THE MICHIGAN BARRIER FREE DESIGN LAW AND THE

AMERICANS WITH DISABILITIES ACT (ADA).

E. WOOD DOOR VENEER AT DOOR PAIRS SHALL BE "PAIR MATCHED" AND "SET MATCHED"; REFER TO SPECIFICATIONS FOR ADDITIONAL QUALITY STANDARDS.

128A BREAKROOM 3-0 x 7-0 1 H.M. PAINT N H.M. PAINT 1 - 60 MIN 1

X

A9.1

BASE DETAILX

TYP.

SCALE: 1 1/2"=1'-0" AT CARPET

BASE DETAILX

TYP.

SCALE: 1 1/2"=1'-0" AT VCT

HEAD / JAMB DETAILX

A9.1

SCALE: 1 1/2"=1'-0"

GYPSUM BOARD PARTITION DETAILX

TYP.

SCALE: 3"=1'-0" AT UNDERSIDE OF ROOF

DOOR FRAMING DETAILX

TYP.

SCALE: 3/4"=1'-0"

128.1A CORRIDOR 3-6 x 7-0 2 H.M. PAINT F H.M. PAINT 1 - 60 MIN 1,2

128.1B CORRIDOR 3-0 x 7-0 2 H.M. PAINT F H.M. PAINT 1 - 60 MIN 1,2

SET #2

1 1/2 PAIR HINGES

1 EXIT HANDLESET

1 CLOSER

1 MAGNETIC HOLD OPEN

128.1C CORRIDOR ETR ETR ETR ETR - H.M. PAINT - - ETR -

128.1D CORRIDOR ETR ETR ETR ETR - H.M. PAINT - - ETR -

128.1E CORRIDOR ETR ETR ETR ETR - H.M. PAINT - - ETR -

128.1F CORRIDOR ETR ETR ETR ETR - H.M. PAINT - - ETR -

128.1G CORRIDOR ETR ETR ETR ETR - H.M. PAINT - - ETR -

128.1G CORRIDOR ETR ETR ETR ETR - H.M. PAINT - - ETR -

Page 11: 060 - Procurement & Strategic Sourcing

3

'

-

5

"

2'-6

1

/2

"

2'-6 1/2"

6"

3'-3"

3'-3

"

6"

6"

2'-6"

3

'-

5

"

2'-6

1

/2

"

2'-6 1/2"

6"

3'-3"

3'-3

"

6"

6"

2'-6"

RF-3 (*RB-1)

SV-1 (*RB-1)

RF-1 (*RB-1)

RF-2 (*RB-1)

FINISH FLOOR PLAN

SCALE: 1/4"=1'-0"

N

FLOOR PLAN KEY NOTES:

(TYPICAL THIS SHEET ONLY)

NEW MOSAIC WALL TILE INSTALLED FULL HEIGHT (WT-1); REFER TO INTERIOR

ELEVATIONS FOR LOCATIONS AND DESIGN.

NEW ACCENT PAINT ON WALL (PT-2)

NEW QUARTZ COUNTERTOP (QZ-1) AND P.LAM CABINETS (PL-1); REFER TO INTERIOR

ELEVATIONS FOR LOCATIONS AND DESIGN.

NEW QUARTZ BARTOP (QZ-1) AND STAINLESS STEEL SUPPORT LEGS; REFER TO INTERIOR

ELEVATIONS FOR LOCATIONS AND DESIGN.

NEW PAINT ON WALLS (PT-1)

NEW PAINT ON EXISTING H.M. FRAMES (PT-3)

TOUCH UP PAINT ON EXISTING ELEVATOR DOORS AS NEEDED (PT-4)

EXISTING WALL AND BASE FINISH TO REMAIN

NEW TRANSITION STRIP; CONTRACTOR TO VERIFY FLOORING TRANSITION IN FIELD AND

SELECT FROM TRANSITIONS PROVIDED IN LIST OF MATERIALS.

NEW PAINT ON EXISTING H.M. DOOR AND FRAME (PT-3)

1

2

FLOOR PATTERN LEGEND

(TYPICAL THIS SHEET ONLY)

(* DENOTES WALL BASE USED)

1

GENERAL NOTES:

(TYPICAL THIS SHEET ONLY)

1. REFER TO MATERIAL / FINISH SCHEDULE FOR SPECIFIC FINISH TYPES.

2. CONTACT ARCHITECT SHOULD ANY FINISH DISCREPANCIES OCCUR.

3. THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO CONVEY NECESSARY DESIGN

INFORMATION.

4. PATCH ALL HOLES, ETC. LEFT BY ALL TRADES (INCLUDING ELECTRICAL AND

MECHANICAL) PRIOR TO PAINTING. PAINT WALL(S) OR CEILING(S) NOT SCHEDULED TO

BE PAINTED, WHICH HAVE HAD PATCHING, FROM INSIDE CORNER TO INSIDE CORNER

ACROSS ENTIRE SURFACE.

5. FLOORING CONTRACTOR SHALL INCLUDE FLOOR PREPARATION IN THEIR BASE BID

SCOPE OF WORK. ANTICIPATE AN APPLICATION OF FLOOR STONE OVER THE ENTIRE

SURFACE TO BRING LIKE-PRODUCTS TO A LEVEL CONDITION THAT MEETS OR

EXCEEDS THE SUBFLOOR TOLERANCES ESTABLISHED BY PRODUCT MANUFACTURER.

WHERE MATERIAL IS TO BE INSTALLED AT SLAB ON GRADE CONDITIONS, MOISTURE

TESTS SHALL BE CONDUCTED OF THE EXISTING SLAB TO ENSURE THE SUBFLOOR

MEETS PRODUCT REQUIREMENTS. AT FLOOR TILE INSTALLATIONS, THE MOVEMENT

GUIDELINES ESTABLISHED IN EJ171-05 SHALL BE FOLLOWED, INCLUDING THE USE OF

BOND BREAKER TAPES AS RECOMMENDED.

6. REFER TO FLOOR PATTERN LEGEND FOR FLOOR MATERIAL UNLESS NOTED ON PLAN.

7. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND CEILING FINISHES.

FINISH KEY

PULLS

MANUFACTURER: RICHELIEU

STYLE: CLASSIC METAL HANDLE PULL - 6500

PRODUCT NUMBER: BP650020128195

FINISH: BRUSHED NICKEL - 195

LOCATION: BASE CABINETS, DRAWERS

QUARTZ SURFACE

MANUFACTURER: CAMBRIA

STYLE/COLOR: TEMPLETON

LOCATION: SEE FINISH FLOOR PLAN FOR EXACT LOCATION

CONTACT: GEORGE PAPALEXIS 231.769.5821

06410 - ARCHITECTURAL CASEWORK

06415 - COUNTERTOPS

WALL TILE

MANUFACTURER: GENESEE TILE / STONE PEAK

STYLE: QUARTZITE

COLOR: IRON

SIZE: NEW MOSAIC DESIGN 4 12X24

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

CONTACT: ERIN CHESLEY 810.459.0229

GROUT: LATICRETE PERMACOLOR GROUT

COLOR: 45 RAVEN

THICKNESS: 1/8"

09300 - CERAMIC TILE, GLASS MOSAIC, ETC.

15000 - ELECTRICAL

FACE PLATES

COLOR: BRUSHED STAINLESS STEEL

DEVICES

COLOR: BLACK

WT-1

QZ-1

-

09650 - RESILIENT FLOORING

RUBBER BASE

MANUFACTURER: NORA

COLOR: 6294 STONE GREY

SIZE: 4"

PROFILE: STRAIGHT

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

RUBBER FLOORING

MANUFACTURER: NORA

STYLE: SENTICA

COLOR: 6521 SUNDAY PAPER

THICKNESS: 2.0MM

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

RF-1

RB-1

RF-2RUBBER FLOORING

MANUFACTURER: NORA

STYLE: SENTICA

COLOR: 6523 ROAD TRIP

THICKNESS: 2.0MM

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

RF-3RUBBER FLOORING

MANUFACTURER: NORA

STYLE: SENTICA

COLOR: 6522 EXPEDITION

THICKNESS: 2.0MM

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

TS-1

TS-2

TS-2

TS-3

TS-3

TS-3

TS-3

TS-3

TS-2

TS-2 TS-1

TS-1

TS-1

TS-1

RUBBER STAIR TREADS

MANUFACTURER: NORA

COLOR: 0749 STONE GREY

STYLE: NORAMENT 920 ROUND STAIRTREAD W/

INTEGRATED RISER

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

STR-1

09511 - SUSPENDED ACOUSTICAL CEILING

CEILING TILE

MANUFACTURER: ARMSTRONG

STYLE: ULTIMA 1901

COLOR: WHITE

SIZE: 24X24

EDGE: TEGULAR

GRID PROFILE: 15/16"

ACT-1

TS-1RUBBER TRANSITION STRIP

MANUFACTURER: JOHNSONITE

STYLE: SLT-63-C (SLIM LINE TRANSITIONS)

COLOR: 63 BURNT UMBER

TRANSITION: 1/4" TO 0.80"

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

NOTES: USE SLTC-63-C WHERE NEEDED

INTERIOR FIELD PAINT

MANUFACTURER: SHERWIN WILLIAMS

COLOR: TO MATCH BENJAMIN MOORE FOSSIL/ AF65

FINISH: EGGSHELL

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

09910 - PAINT

INTERIOR ACCENT PAINT

MANUFACTURER: SHERWIN WILLIAMS

COLOR: SW7616 BREEZY

FINISH: EGGSHELL

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

DOOR AND FRAME PAINT

MANUFACTURER: SHERWIN WILLIAMS

COLOR: SW7048 URBANE BRONZE

FINISH: SEMI-GLOSS

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

PT-3

PT-2

PT-1

09650 - RESILIENT FLOORING

LOCATOR PLAN

NOT TO SCALE

N

PROJECT AREA

TS-2

3

4

3

3

4

5

5

5

5

5

5

6

7

7

7

6

6

6

6

6

6

10

10

6

6

6

6

ELEVATOR DOOR AND FRAME PAINT

MANUFACTURER: SHERWIN WILLIAMS

COLOR: TO MATCH EXISTING

FINISH: TO MATCH EXISTING

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

PT-4

SOFFIT PAINT

MANUFACTURER: SHERWIN WILLIAMS

COLOR: SW7695 MESA TAN

FINISH: EGGSHELL

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

PT-5

VINYL PLANK

MANUFACTURER: PATCRAFT

STYLE: NORTHRIDGE/ WOOD PLANK

COLOR: SPICED TEA 02544

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

LVT-1

TS-2RUBBER TRANSITION STRIP

MANUFACTURER: JOHNSONITE

STYLE: SLT-63-B (SLIM LINE TRANSITIONS)

COLOR: 63 BURNT UMBER

TRANSITION: 1/8" TO 0.80"

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

8

8

8

8

8

TS-3RUBBER TRANSITION STRIP

MANUFACTURER: JOHNSONITE

STYLE: SLT-63-J (SLIM LINE TRANSITIONS)

COLOR: 63 BURNT UMBER

TRANSITION: 0.80" TO SUBFLOOR

LOCATION: SEE FINISH PLAN FOR EXACT LOCATION

9

9

9

2

10

Page 12: 060 - Procurement & Strategic Sourcing

2'-6"

6"

2'-6"

6"

RF-3 (*RB-1)

RF-1 (*RB-1)

RF-2 (*RB-1)

FINISH FLOOR PLAN - SECOND FLOOR

SCALE: 1/4"=1'-0"

N

FLOOR PLAN KEY NOTES:

(TYPICAL THIS SHEET ONLY)

NEW PAINT ON WALLS (PT-1)

NEW STAIR TREADS (STR-1)

TOUCH UP PAINT ON EXISTING ELEVATOR DOORS AS NEEDED (PT-4)

NEW PAINT ON EXISTING H.M. DOOR AND FRAMES (PT-3)

NEW PAINT ON EXISTING RAILINGS (PT-3)

NEW TRANSITION STRIP; CONTRACTOR TO VERIFY FLOORING TRANSITION IN FIELD AND

SELECT FROM TRANSITIONS PROVIDED IN LIST OF MATERIALS.

1

2

FLOOR PATTERN LEGEND

(TYPICAL THIS SHEET ONLY)

(* DENOTES WALL BASE USED)

1

GENERAL NOTES:

(TYPICAL THIS SHEET ONLY)

1. REFER TO MATERIAL / FINISH SCHEDULE FOR SPECIFIC FINISH TYPES.

2. CONTACT ARCHITECT SHOULD ANY FINISH DISCREPANCIES OCCUR.

3. THIS SHEET IS INTENDED TO BE PRINTED IN COLOR TO CONVEY NECESSARY DESIGN

INFORMATION.

4. PATCH ALL HOLES, ETC. LEFT BY ALL TRADES (INCLUDING ELECTRICAL AND

MECHANICAL) PRIOR TO PAINTING. PAINT WALL(S) OR CEILING(S) NOT SCHEDULED TO

BE PAINTED, WHICH HAVE HAD PATCHING, FROM INSIDE CORNER TO INSIDE CORNER

ACROSS ENTIRE SURFACE.

5. FLOORING CONTRACTOR SHALL INCLUDE FLOOR PREPARATION IN THEIR BASE BID

SCOPE OF WORK. ANTICIPATE AN APPLICATION OF FLOOR STONE OVER THE ENTIRE

SURFACE TO BRING LIKE-PRODUCTS TO A LEVEL CONDITION THAT MEETS OR

EXCEEDS THE SUBFLOOR TOLERANCES ESTABLISHED BY PRODUCT MANUFACTURER.

WHERE MATERIAL IS TO BE INSTALLED AT SLAB ON GRADE CONDITIONS, MOISTURE

TESTS SHALL BE CONDUCTED OF THE EXISTING SLAB TO ENSURE THE SUBFLOOR

MEETS PRODUCT REQUIREMENTS. AT FLOOR TILE INSTALLATIONS, THE MOVEMENT

GUIDELINES ESTABLISHED IN EJ171-05 SHALL BE FOLLOWED, INCLUDING THE USE OF

BOND BREAKER TAPES AS RECOMMENDED.

6. REFER TO FLOOR PATTERN LEGEND FOR FLOOR MATERIAL UNLESS NOTED ON PLAN.

7. REFER TO REFLECTED CEILING PLAN FOR CEILING HEIGHTS AND CEILING FINISHES.

LOCATOR PLAN

NOT TO SCALE

N

PROJECT AREA

TS-1

TS-1

1

2

3

3

3

4

4

4

4

4

4

5

5

5

6

6

6

6

Page 13: 060 - Procurement & Strategic Sourcing
Page 14: 060 - Procurement & Strategic Sourcing
Page 15: 060 - Procurement & Strategic Sourcing