Upload
others
View
2
Download
0
Embed Size (px)
Citation preview
1
20
16
-06
CNIM Group
CORIOLIS µ, AN INNOVATIVE AIR SAMPLER
2
20
16
-06
CNIM Group
BERTIN INSTRUMENTS, MONITOR THE INVISIBLE
Bertin Instruments is a brand of CNIM Group
dedicated to innovative measurement and sampling solutions
for key worldwide markets
Lab Equipment
(sample preparation, air sampler)
Nuclear Instrumentation
(environmental radiation monitoring systems, radon professional monitoring, radiation portal monitors, health physics
equipment)
Defense, Security
and Safety (CBRN threat detection, gas
detection, optronics)
With the expertise of:
3
20
16
-06
CNIM Group
CONTAMINATION SOURCES & TRADITIONAL CONTROL
Sources of contamination • People • Raw materials • Water • Air
Monitoring by - Passive impaction - Active impaction - Filtration - Impinger
Hospital
Waste
Agriculture
Industry
Air in Building Pharma
4
20
16
-06
CNIM Group
10 YEARS OF WET CYCLONE TECHNOLOGY IMPLEMENTATION
MonaLisa Project 2006-2009
Validation of a new method for pollen and allergen detection
French Army Project Since 2006
Portable air sampler for airborne pathogens detection
Coriolis µ
Since 2009
Air Sampler for bio-contamination
quality control
5
20
16
-06
CNIM Group
CORIOLIS µ, COLLECT MICRO ORGANISMS INTO A LIQUID!
6
20
16
-06
CNIM Group
COMPLEMENTARY SOLUTION: CORIOLIS TECHNOLOGY
• Particles from 0.5 to 20 µm
• Bacteria, fungi, spores, viruses, pollens, allergens, endotoxins…
1- Pre-filled sterile cone with adapted collection liquid
3- Particles are concentrated into the collection liquid
2- Air & particles enter into the cone and form a vortex: aspirated particles are centrifuged with the collection liquid on the wall
Air
Collection liquid
Particles
7
20
16
-06
CNIM Group
HOW CORIOLIS GET OVER LIMITATIONS OF TRADITIONAL METHODS?
Limitation of traditional technologies
Only cultivable flora
Limited Air flow rate
Limited time of collection
Coriolis advantages
Allergens, virus, fungi…
High Air Flow rate (300 L/min)
Long time monitoring available (6h)
Result in days or weeks
Short response time in hours
• High air flow rate: 300 L/min
• Collection from 1 to 10 min,
• Up to 6 hours sampling with Long Time Monitoring
• Light: 3 kg
• Easy decontamination
• Battery operated
8
20
16
-06
CNIM Group
QUALIFICATION BY HPA - UK
Physical and biological efficiency of the Coriolis® technology are qualified according to ISO 14698-1 Annex 1- July 2008 requirements
• Physical efficiency: Bacillus atrophaeus NCTC 10073
• Biological efficiency of 78% for Staphylococcus epidermidis ATCC 14990
Size of interest
HPA Porton Down (UK)
d50 <0.5µm
100% for particles > 4 µm
9
20
16
-06
CNIM Group
COMPATIBLE WITH BIOLOGICAL ANALYSIS
10
20
16
-06
CNIM Group
DETAILED WORKFLOW FOR IDENTIFICATION BY CULTURE
Culture and results
24 hours
Sampling
10 min
Sample Preparation
10 min
11
20
16
-06
CNIM Group
DETAILED WORKFLOW FOR IDENTIFICATION BY QPCR
Sample prep
1 min
DNA extraction
30 min
qPCR reaction & analysis
60-90 min
Sampling
10 min
12
20
16
-06
CNIM Group
CORIOLIS RANGE
13
20
16
-06
CNIM Group
CORIOLIS µ PRODUCT
Biological Air Sampler for bio-contamination quality control • High air flow rate: 300 L/min
• Collection from 1 to 10 min,
• Up to 6 hours sampling with Long Time Monitoring
• Light: 3 kg
• Easy decontamination
• Battery operated
14
20
16
-06
CNIM Group
CORIOLIS
Ref. 05027-662-RD001
LTM Option for Coriolis µ air sampler includes :
1 x Platform for Coriolis µ
1 x LTM Tripod
1 x Air intake for LTM
1 x Collection liquid in bottle
1 x Tubing kit
1 x Shipment box
• Ref. 05027-030-RD003
• Coriolis µ air sampler includes :
• 1 x Coriolis body
• 1 x Air intake
• 1 x Cane
• 4 x Cones & Caps
• 1 x Battery & 1 Charger
• 1 x Power Supply
• 1 x User manual
• 1 x Shipment box
15
20
16
-06
CNIM Group
ACCESSORIES
Air Intake & LTM Air Intake
Autoclavable
Ref. 05027-600-003
Ref. 05027-662-PE103
Cane
Autoclavable
Ref. 05027-600-PE101
Air Intake with 25 mm
Connection
Autoclavble – adapted for pipe
connection
Ref. 05027-600-PE104
Exhaust Pipe connection
Adapted for clean rooms
Ref. 05027-030-ExPi
NiMH Battery and charger
Ref. 05027-622-RD001
Ref.05027-600-PL010
Coriolis µ platform and tripod
For outdoor collection
Ref. 05027-672-RD001
16
20
16
-06
CNIM Group
CONSUMABLES
Tubing kit
The tubing kit contains 1 meter
of tubing and a specific cap with
0,25µm filter for collection
liquid bottle.
Ref. 05237-1-204
Collection liquid in bottle
1x 250 mL bottle prefilled with
200 mL of collection liquid
Ref. 05237-1-203
Collection liquid doses sterile
(by 50)
50 units of sterile collection
liquid doses. 15mL each.
Ref. 05237-1-202
Sterile cones & caps -
Single use (by 50)
50 units of sterile cones
and caps. Each cone and
cap are packed in a single
sterile pouch.
Ref. 05237-1-101
Cones & caps - Single use (by
50)
50 units of cones and caps.
Ref. 05237-1-003
17
20
16
-06
CNIM Group
SERVICES
• Calibration – Once a Year
Specific calibration bench at our Support Center (Aix en Provence – FR)
Ref. FLOW CTRL
• Flow control – to control the flow by itself
Ref. 05027-340-RD001
After sales services – diagnostic and repair
Price on request
• Application Center
Accessible on the web site
18
20
16
-06
CNIM Group
APPLICATION & CASES STUDIES
19
20
16
-06
CNIM Group
POLLUTION & ENVIRONNENT
Outdoor surveillance / Bioburden
Indoor Air Quality: public health, prevention of diseases and allergies (e.g. in offices, child-care-centers, schools…)
Pollen dispersal / cross pollination / Crop diseases
• Example : Kiwi crop (bacteria disease PSA-V (Pseudomonas syringae pv actinidiae - virulent)
• Greenhouse cultivation • Field experiment
Epidemiology study (ex.: Oak oidium Inra 33 Cestas Dynamique temporelle de dépôts de spores)
20
20
16
-06
CNIM Group
CASE STUDY: COMPOSTING SITE
Investigation on the simultaneous presence of amoebae and Legionella in the compost piles and in the bioaerosols developed from pile fermentation
• 250 L/min, 4 min. sampling (1m3)
• Culture analysis
• The protozoa were cultured on non-nutritive agar plates covered with E.coli as a food source.
• Legionella spp. were cultivated on GVPC agar plates and by co-culture with axenic Acanthamoaba polyphaga for two weeks.
21
20
16
-06
CNIM Group
CASE STUDY: BARCELONA SUBWAY
Investigation of the air quality in the Barcelona Subway system during a cold period:
• 200L/min for 10 min
• Inside trains, platforms and lobbies
• Detection by QPCR & sequencing
• Low concentration of Influenza A&B
• High level of bacterial bioburden (104 bacteria/m3)
22
20
16
-06
CNIM Group
ANIMAL SCIENCE & VETERINARY
Coriolis can be used to monitor the air for potential contaminants that are a health risk
Areas with High animal densities / livestock houses / CAFO (Confined animal feeding operations) • Swine confinement building (barns), Turkey confinement house, Poultry barns,
Dairy barns, Duck-fattening unit, Cattle industries
Animal disease outbreak • Disease transmission among animals • ex.: foot and mouth (FAM) disease, avian influenza, Newcastle disease…)
23
20
16
-06
CNIM Group
CASE STUDY: POULTRY CONTAMINATION
Aflatoxin B₁ detection in Poultry units with qPCR. Aflatoxin B₁ has been recognized to produce cancer in human liver. • 300 L/min • 3 indoors samples from 2 different poultry
units • DNA extraction • Specific qPCR to validate detection
24
20
16
-06
CNIM Group
CASE STUDY: GLUTEN DETECTION
Number of gluten-free consumers has increased greatly in recent years. Goal: create a specific area in the production workshop dedicated to the production of gluten free products
• A1: 300L/min for 10 and 20 min when the machines were stopped and during production time
• A2: 300L/min for 10 and 20 min and at 200L/min for 5 min during production time
• Detection by ELISA Kit
Sampling parameters
[Gluten]
(mg of gluten/kg of
liquid collection)
[Gluten]
(mg of gluten/m3 of air)Results
Control (distilled water) <5 ppm - OK
A1-300L/min-20 min
Machines stopped<5 ppm
< 0,075 mg de gluten/6000L of air
< 12,5 µg de gluten/m3 of air
A1-300L/min-10 min
Machines stopped<5 ppm
< 0,075 mg de gluten/3000L of air
< 25 µg de gluten/m3 d'air
A1-300L/min-20 min
Production time<5 ppm
< 0,075 mg de gluten/6000L of air
< 12,5 µg de gluten/m3 of airLow gluten contamination
A1-300L/min-10 min
Production time8 ppm
0,12 mg de gluten/3000L of air
40 µg de gluten/m3 of air
Increase of the level of gluten
during the production
Low gluten contamination
Sampling parameters
[Gluten]
(mg of gluten/kg of
liquid collection)
[Gluten]
(mg of gluten/m3 of air)Results
A2-300L/min-20 min
Production time35 ppm
0,525 mg de gluten/6000L of air
87,5 µg de gluten/m3 of air
54 ppm0,81 mg de gluten/3000L of air
270 µg de gluten/m3 of air
44 ppm0,66 mg de gluten/3000L of air
220 µg de gluten/m3 of air
A2-200L/min-5 min
Production time18 ppm 270 µg de gluten/m3 d'air
A2-300L/min-10 min
Production time
Detection of gluten at a high
concentration -> the
production of gluten-free
products close to this area is
not possible
25
20
16
-06
CNIM Group
BIOMEDICAL & HEALTH
Coriolis can contribute to detect : • Virus and infectious agent such as Mers, H1N1, SRAS …
• Bacteria
• Fungi: Aspergillus
Early detection of pathogen can help limit the spreading in a hospital unit
Coriolis in routine can sustain high-quality of air and limit the risk of hospital-based infections
26
20
16
-06
CNIM Group
CASE STUDY: HOSPITAL CONTAMINATION
RSV (Respiratory Synticial Virus) detection in the surrounding patients • 300 L/min - 5min • Filtration and concentration of the sample • 30 air samples, at most 2 days after the diagnostic • Positive results by RT-PCR RSV real time for 6 samples for 3 children.
27
20
16
-06
CNIM Group
RESEARCH & DEVELOPMENT
Every topic related to bio-aerosol: • Lascaux Cave
• Archeologic Museum
• Amazon forest in Guyana
• Artic
• Coral reef barrier...
28
20
16
-06
CNIM Group
Epidemiological
investigation of MERS-CoV infections in bat or
camel flocks
Coriolis bio-aerosol
sampling surrounding
patients & medical staff
infected with MERS-
CoV
CASE STUDY: MERS SYNDROME-CORONAVIRUS DATA & PERSPECTIVES
Use of Coriolis
technology
Laboratory studies
with Coriolis μ
29
20
16
-06
CNIM Group
CONCLUSION
Innovative and comprehensive system
• High Air Flow Rate
• LTM Platform
• Easy to use
• Liquid Sampling Molecular Analysis
• Compatible with all Market and Application
30
20
16
-06
CNIM Group
www.bertin-instruments.com