Upload
haseebamer
View
5
Download
3
Tags:
Embed Size (px)
DESCRIPTION
layout for ventilation
Citation preview
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED B+GF+5+GYM+ROOF
RESIDENTIAL BUILDING
LEGENDS:
GENERAL NOTES
: EXUAST AIR DIFFUSER
FCU : FAN COIL UNIT
CU : CONDENSING UNIT
S.ATT : SOUND ATTENUATOR
EXF : EXTRACT FAN
EAL : EXTRACT AIR LOUVER
FAL : FRESH AIR LOUVER
SAR : SUPPLY AIR REGISTER
SAD : SUPPLY AIR DIFFUSER
RAD : RETURN AIR DIFFUSER
RAG : RETURN AIR GRILLE
EAG : EXTRACT AIR GRILLE
DG : DOOR GRILLE
TG : TRANSFER GRILLE
FAD : FRESH AIR DUCT
TED : TOILET EXTRACT AIR DUCT
KED : KITCHEN EXTRACT AIR DUCT
SALD : SUPPLY AIR LINEAR DIFFUSER
RALD : RETURN AIR LINEAR DIFFUSER
SJD : SUPPLY JET DIFFUSER
RJD : RETURN JET DIFFUSER
GE : GENERAL EXHAUST
SA : SUPPLY AIR
RA : RETURN AIR
KEF : KITCHEN EXTRACT FAN
MD : MOTORIZED DAMPER
CDP : CONDENSATE DRAIN PIPE
NRV : NON RETURN VALVE
DC : DRAIN COCK
FE : FLEXIBLE CONNECTION
VE : VIBRATION ELIMINATOR
M : MOTORIZED
AAV : AUTOMATIC AIR VENT
FA : FRESH AIR
EA : EXTRACT AIR
VCD : VOLUME CONTROL DAMPER
NRD : NON RETURN DAMPER
PRD : PRESSURE RELIEF DAMPER
STL : SAND TRAP LOUVER
: FIRE DAMPER
: VOLUME CONTROL DAMPER
: NON RETURN DAMPER
: THERMOSTAT
: RETURN DUCT WITH BELL MOUTH
: SUPPLY DUCT
: RETURN DUCT
SYMBOLS:
: SUPPLY AIR DIFFUSER
: RETURN AIR DIFFUSER
: SUPPLY AIR REGISTER
: RETURN AIR GRILL
1. THE CONTRACTOR SHALL BE RESPONSIBLE FOR THE CO-ORDINATION OF ALL SERVICES.
2. ALL DUCT, GRILL, DIFFUSER SIZES ARE IN MM.
3. ALL DUCT WORK TO BE INSULATED IN ACCORDANCE WITH THE SPECIFICATIONS.
4. ALL CONDENSATE DRAINS FROM EACH FCU WHETHER SHOWN ON DRAWING OR
NOT SHALL RUN WITH A FALL TO THE NEAREST WASTE STACK OR FLOOR DRAIN VIA
U-TRAPS.
5. ALL DUCT CONNECTIONS TO A/C UNITS SHALL BE OF THE FLEXIBLE TYPE DUCT
CONNECTION.
6. ACCESS PANELS TO BE PROVIDED WITHIN FALSE CEILING AT ALL LOCATIONS OF F,
VALVES, FD, VCD, NRD & SPD. CONTRACTOR SHALL CO-ORDINATE WITH ALL MEP
SERVICES & FALSE CEILING LAYOUT TO ENSURE THAT COMMON ACCESS PANELS TO BE
PROVIDED FOR MAINTENANCE.
7. FIRE DAMPERS SHALL BE PROVIDED WHERE EVER DUCTS CROSS FIRE ZONES, AS
IDENTIFIED BY THE ARCHITECT WHETHER SHOWN ON DRAWINGS OR NOT. ALL FD'S TO
HAVE BLADES OUT OF THE AIR STREAM AND 2HR RATED. ALL FD'S TO HAVE INSULATED
ACCESS PANEL WITHIN DUCT.
8. SUITABLE APPROVED SLEEVES SHALL BE PROVIDED WHERE BOTH INSULATED AND NON
INSULATED DUCTS PASS THROUGH WALLS/FLOORS ETC. ALL GAPS TO BE SEALED WITH
APPROVED TYPE MATERIAL.
9. ALL DUCT WORK WITHIN 3.0M OF FAN COIL UNIT OUTLETS SHALL BE ACCOUSTICALLY
LINED.
10. NON-RETURN DAMPER (NRD) TO BE PROVIDED AFTER EACH DUCTED EXTRACT
FAN.
11. CONTRACTOR SHALL SUBMIT PERFORMANCE TEST CERTIFICATE FOR HVAC EQUIPMENT
TO CONFIRM THAT IT CAN PRODUCE THE SCHEDULE DUTY AT THE SPECIFIED
CONDITIONS.
12. VCD'S SHALL BE PROVIDED ON ALL SUPPLY AND RETURN DUCT BRANCHES.WHETHER
SHOWN ON DRAWINGS OR NOT.
13. POWER FACTOR CAPACITORS SHALL BE PROVIDED TO ALL MECHANICAL EQUIPMENTS
(PUMPS,A/C UNITS,...etc).
14. ALL SUPPLY AND EXTRACT DIFFUSERS / GRILLES SHALL HAVE BUILT IN VCD FOR FINAL
FINE TUNING.
15. TOILET / PANTRY DOORS SHALL HAVE 20MM UNDERTS FOR AIR CIRLATION,DOOR
GRILLES SHALL NOT BE USED UNLESS OTHERWISE STATED/INDICATED.
16. AIRTIGHT PARTIONS SHALL BE PROVIDED ABOVE FALSE CEILING WHERE EVER REQUIRED
TO SEGREGATE THE RETURN AIR FOR ALL F'S.
17. ALL OPENING FOR RETURN AIR PATH ABOVE FALSE CEILING TO BE PROVIDED WITH FD
WHERE A/C SUPPLY DUCT HAS FD.
18. ANY DISCREPANCIES ARE TO BE BROUGHT TO THE ATTENTION OF THE ENGINEER AND
RESOLVED PRIOR TO FINALIZATION OF CONTRACT AND VARIATION CLAIMS AS SUCH,
SHALL NOT BE ENTERTAINED.
19. SHOWN LOCATIONS OF T ARE TENTATIVE FINAL LOCATION TO BE CO-ORDINATE WITH
ARCHITECT'S DURING CONSTRUCTION STAGE.
20. ALL FRESH AIR AND GENERAL EXTRACT OUTLET TO BE TERMINATED ADJACENT TO EACH
F WITH VCD AND WIRE MESH OF STAINLESS STEEL.
21. FLEXIBLE CONNECTORS TO BE USED WHERE A/C DUCTS/CHW PIPE CROSS BUILDING
EXPANSION JOINT.
22. ALL ELECTRICAL LOADS SHOWN ON ELETRICAL TENDER DRAWINGS / SPECIFICATIONS TO
BE CHECKED & CONFIRMED AND THE CONTRACTOR SHALL INCLUDE IN HIS QUOTE AND
UPGRADING AS REQUIRED AT TENDER STAGE.
23. PROPER WALKWAY BRIDGES FOR ROOF SERVICES SHALL BE PROVIDED WHERE
NECESSARY.
24. ALL EXPOSED ANGLE SUPPORTS FOR DUCTS SHALL BE PAINTED AS SPECIFIED COLOUR
SUBJECT TO ARCHITECT'S APPROVAL.
25. FINAL LOCATION OF FAL & EAL TO BE CO-ORDINATED WITH ARCHITECT'S AT
SITE.COLOUR SUBJECT TO ARCHITECT'S APPROVAL.
26. WHERE MORE THAN ONE SERVIVE (ELECTRICAL,CABLES,DUCTS) IS ROUTED THROUGH
THE SAME AREA,THEY SHALL BE SUPPORTED BY STRUCTURAL FRAME SUPPORT WITH
SERVICES.
27. ALL SUPPLY AIR DIFFUSER GRILLE PLENUM SHALL BE INTERNALLY LINED AND PAINTED
BLACK INTERNALLY.
28. CONTRACTOR TO ENSURE THAT THE SPECIFIED ROOM NOISE LEVELS (NC) ARE TO
MAINTAINED.CONTRACTOR SHALL INCLUDE ATTENUATORS,ACOUSTIC INSULATION TO
DUCTS,etc TO ACHIEVE THE SPECIFIED NOISE LEVEL.
29. CONTRACTOR SHALL FORWARD ACTUAL PHYSICAL DIMENSIONS,WEIGHTS OF EQUIPMENT
AFTER APPROVAL FOR STRUCTURAL ENGINEER.
30. CONTRACTOR TO CO-ORDINATE WITH STRUCTURAL DRAWINGS FOR OPENINGS AND
PENETRATIONS.SUBMIT BUILDING WORKSHOP DRAWING FOR STRUCTURAL ENGINEER
APPROVAL.ANY OPENING REQUIRED OTHER THAN THAT SHOWN ON STRUCTURAL DRAWING
SHALL BE APPROVED BY STRUCTURAL ENGINEER.
31. ALL SLAB SUSPENDED SUPPORT LOCATION SHALL BE SUBMITTED FOR APPROVAL.NO
DRILLING OR FIXING OF SUPPORT FROM OR ON SLAB SHALL BE CARRIED OUT WITH OUT
THE STRUCTURAL ENGINEER'S APPROVAL.
32. ACOUSTIC MATS SHALL BE PROVIDED ON FALSE CEILING TILES BELOW FAN COIL
UNITS AREA IN ORDER TO ACHIEVE THE SPECIFIED NOISE LEVELS.
33. FINAL LOCATION OF ALL AIR OUTLET SHALL BE CO-ORDINATED WITH FINAL FALSE
CEILING LAYOUT APPROVED BY ARCHITECT'S.
34. THE EXTERNAL STATIC PRESSURE FOR FANS, FCU AND AHUs ARE INDICATIVE, BUT
ACTUAL ESP SHALL BE CALLATED BY CONTRACTOR AND OBTAIN ENGINEER APPROVAL.
35. CONTRATOR IS FULLY RESPONSIBLE TO BALANCE WATER & AIR DISTRIBUTION AS PER
DESIGN DRAWING.
SMD : SMOKEMOTORIZED DAMPER
BEF : BASEMENT EXTRACT FAN
F/B : FROM BELOW
T/B : TO BELOW
T/A : TO ABOVE
GED : GARBAGE EXHASUT AIR DUCT
SED : SMOKE EXHAUST AIR DUCT
SPD : STAIR CASE PRESSURAZATION DUCT
EAG : EXHAUST AIR GRILL
F/A : FROM ABOVE
HVAC LEGENS & NOTES
V-00 65
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
BASEMENT FLOOR PLAN
A1 / 1:100
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
BASEMENT FLOOR PLAN
PLOTLIMIT
R O A D 1 8 . 5 0 m
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 6
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 4
N E I G H B O U R P L O T 4 2 1 - 0 4 2 2\A1;30.48
\A1;45.72
\A1;30.48
\A1;45.72
PLOTLIMIT
PLOTLIMIT PLOTLIMIT
GENERATOR
PUMP ROOM
WATER TANK
104.69 Sqmtr
240.78 Cumtr
2.3m Water Height
3.0m Clear Height
+4.10
S.F.L.
004003
006
005 008007
009
002
001
010
011
013 012
UP
A
+3.93
S.F.L.
\A1;2.05
GENERATORE SIZE mtr
EXHAUST DUCT T/A
EXHAUST PIPE T/A
ATS PANEL
DIESEL TANK
F.A
750x400
750x400
2000 CFM
VENTILATION LAYOUT
V-01
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
FRESH AIR DUCT
VCD
VOLUME CONTROL DAMPER
EXHAUST AIR DIFFUSER
EXHAUST AIR DUCT
FA
FRESH AIR
EA
EXHAUST AIR
CFM
CUBIC FEET PER MINUTE
FD
FIRE DAMPER
SMD
SMOKE MOTORISED DAMPER
SED
SMOKE EXHAUST DUCT
EAG
EXHAUST AIR GRILL
FAHU
FRESH AIRHANDLING UNIT
SPF
STAIR CASE PRESSURIZATION FAN
MD
MOTORISED DAMPER
SEF
SMOKE EXHAUST FAN
EXF
EXHAUST FAN
NRD
NON RETURN DAMPER
SPD
STAIR CASE PRESSURIZATION DUCT
KEA
KITCHEN EXTRACT AIR
KED
KITCHEN EXHAUST DUCT
TEA
TOILET EXTRACT AIR
TOILET EXHAUST DUCT
TED
66
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
GROUND FLOOR PLAN
A1 / 1:100
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
GROUND FLOOR PLAN
PLOTLIMIT
R O A D 1 8 . 5 0 m
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 6
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 4
N E I G H B O U R P L O T 4 2 1 - 0 4 2 2\A1;30.48
\A1;45.72
\A1;30.48
\A1;45.72
PLOTLIMIT
PLOTLIMIT PLOTLIMIT
2.5 Cum
2.5 Cum
LV ROOM
TELEPHONE
GARBAGE
MAIN ENTRANCE
ENTRANCE
EXIT
UP
01
02
03
04
05
06
07
08
09
10
11
12
13
14
1516171819
2021
22
23
24
25
26
27
28
29
30
31 32 33 34 35
+0.45
F.F.L.
004
003
006
005 008007
009
011
010012
002
001
UP
B
A
029
028
031
030 033032
034
012013
027
026
UP
DN
015
014
016
018 017
019
021
020022023
024
025
035
CORIDOR
TEMP GATE LEVEL TO BE=+26.45m=0.00
TEMP GATE LEVEL TO BE=+26.45m=0.00 TEMP GATE LEVEL TO BE=+26.45m=0.00
SUB STATION
DN
UP
DN
LIFT
VENTILATION LAYOUT
V-02
400x200
FAD
FCU
G-01
VCD
FA 45 CFM
250 CFM
T/A
EXHAUST DUCT F/A
Outlet Silencer
F.A
750x400
MUK
FRESH AIR GRILL
WITH WIRE MESH
750x400
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
FRESH AIR DUCT
VCD
VOLUME CONTROL DAMPER
EXHAUST AIR DIFFUSER
EXHAUST AIR DUCT
FA
FRESH AIR
EA
EXHAUST AIR
CFM
CUBIC FEET PER MINUTE
FD
FIRE DAMPER
SMD
SMOKE MOTORISED DAMPER
SED
SMOKE EXHAUST DUCT
EAG
EXHAUST AIR GRILL
FAHU
FRESH AIRHANDLING UNIT
SPF
STAIR CASE PRESSURIZATION FAN
MD
MOTORISED DAMPER
SEF
SMOKE EXHAUST FAN
EXF
EXHAUST FAN
NRD
NON RETURN DAMPER
SPD
STAIR CASE PRESSURIZATION DUCT
KEA
KITCHEN EXTRACT AIR
KED
KITCHEN EXHAUST DUCT
TEA
TOILET EXTRACT AIR
TOILET EXHAUST DUCT
TED
67
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
FIRST FLOOR PLAN
A1 / 1:100
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
FIRST FLOOR PLAN
PLOTLIMIT
R O A D 1 8 . 5 0 m
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 6
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 4
N E I G H B O U R P L O T 4 2 1 - 0 4 2 2\A1;30.48
\A1;45.72
\A1;30.48
\A1;45.72
PLOTLIMIT
PLOTLIMIT PLOTLIMIT
101
102
103
104
105
106
107
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
C O R R I D O R E
LIFT
GAR.
BED ROOM
BATH
LIVING
F.F.
BAL.
BED ROOM
KITCHEN
LIVING
BATH
BATH
BAL.
BAL.
BED ROOM
KITCHEN
LIVING
BATH
KITCHEN
BED ROOM
BED ROOM
BALCONY
BED ROOM
BATH
LIVING
F.F.
BAL.
KITCHEN
BED ROOM
KITCHEN
LIVING
BATH
BATH
BAL.
BAL.
BED ROOM
BALCONY
BED ROOM
KITCHEN
LIVING
BATH
BATH
BAL.
BAL.
BED ROOM
BALCONY
BED ROOM
KITCHEN
LIVING
BATH
BATH
BAL.
BAL.
BED ROOM
BALCONY
ELE.
DINING
TEL
BATH
BAL.
W.M.
UP
DN
045
044
026
025 028027 030
029
031
033 032
034
035
036
037038
039
040
041
042043
B
UP
DN
069
068 050
049
052
051
054
053 055
057
056
058
059
060
061
062063
064
065
066
067
A
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
+5.00
F.F.L.
FCU
T-4
FCU
T-7a
FCU
T-3
FCU
T-2a
FCU
T-2b
FCU
T-1b
FCU
T-1a
FCU
T-5b
FCU
T-5a
FCU
T-6a
FCU
T-7b
FCU
T-6b
EA 50 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
STAIR CASE PRESSURIZTION
600X200 SAG
450 CFM
SPD
750x400
SPD
750x400
STAIR CASE PRESSURIZTION
600X200 SAG
450 CFM
VCD
FA 55 CFM
VCD
FA 55 CFM
VCD
FA 140 CFM
VCD
FA 140 CFM
VCD
FA 55 CFM
VCD
FA 140 CFM
VCD
FA 140 CFM
VCD
FA 140 CFM
EA 50 CFM
150X150 ECD
VCD
FA 55 CFM
VCD
FA 55 CFM
VCD
FA 140 CFM
VCD
FA 140 CFM
EA 115 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
SA 660 CFM EACH
450X450 SECD
900x400
900x400
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
650X400SED
KED
TED
1150x600
FAD
390 CFM EACH
300X300 SECD
150 CFM
225X225 SAD/RAD
150 CFM
225X225 SAD/RAD
150 CFM
225X225 SAD/RAD
25 CFM
T/A
100 CFM
100 CFM
VENTILATION LAYOUT
V-03
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
FRESH AIR DUCT
VCD
VOLUME CONTROL DAMPER
EXHAUST AIR DIFFUSER
EXHAUST AIR DUCT
FA
FRESH AIR
EA
EXHAUST AIR
CFM
CUBIC FEET PER MINUTE
FD
FIRE DAMPER
SMD
SMOKE MOTORISED DAMPER
SED
SMOKE EXHAUST DUCT
EAG
EXHAUST AIR GRILL
FAHU
FRESH AIRHANDLING UNIT
SPF
STAIR CASE PRESSURIZATION FAN
MD
MOTORISED DAMPER
SEF
SMOKE EXHAUST FAN
EXF
EXHAUST FAN
NRD
NON RETURN DAMPER
SPD
STAIR CASE PRESSURIZATION DUCT
KEA
KITCHEN EXTRACT AIR
KED
KITCHEN EXHAUST DUCT
TEA
TOILET EXTRACT AIR
TOILET EXHAUST DUCT
TED
68
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
SECOND-FIFTH
TYPICAL FLOOR PLAN
A1 / 1:100
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
SECOND-FIFTH TYPICAL FLOOR PLAN
PLOTLIMIT
R O A D 1 8 . 5 0 m
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 6
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 4
N E I G H B O U R P L O T 4 2 1 - 0 4 2 2\A1;30.48
\A1;45.72
\A1;30.48
\A1;45.72
PLOTLIMIT
PLOTLIMIT PLOTLIMIT
201
202
203
204
205
206
207
UP
DN
091
090 072
071
074
073
076
075 077
079 078080
081
082083
084
085
086
087088
089
W3
A
W3
UP
DN
067
066
048047 050
049
052
051
053
055
054
056
057058
059
060
061
062063
064
065
B
W3
W3
C O R R I D O R E
LIFT
GAR.
BED ROOM
BATH
LIVING
F.F.
BAL.
BED ROOM
KITCHEN
LIVING
BATH
BATH
BAL.
BAL.
BED ROOM
KITCHEN
LIVING
BATH
KITCHEN
BED ROOM
BED ROOM
BALCONY
BED ROOM
BATH
LIVING
F.F.
BAL.
KITCHEN
BED ROOM
KITCHEN
LIVING
BATH
BATH
BAL.
BAL.
BED ROOM
BALCONY
BED ROOM
KITCHEN
LIVING
BATH
BATH
BAL.
BAL.
BED ROOM
BALCONY
BED ROOM
KITCHEN
LIVING
BATH
BATH
BAL.
BAL.
BED ROOM
BALCONY
ELE.
DINING
TEL
BATH
BAL.
W.M.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
+8.35
F.F.L.
FCU
T-4
FCU
T-7a
FCU
T-3
FCU
T-2a
FCU
T-2b
FCU
T-1b
FCU
T-1a
FCU
T-5b
FCU
T-5a
FCU
T-6a
FCU
T-7b
FCU
T-6b
EA 50 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
STAIR CASE PRESSURIZTION
600X200 SAG
450 CFM
SPD
750x400
SPD
750x400
STAIR CASE PRESSURIZTION
600X200 SAG
450 CFM
VCD
FA 55 CFM
VCD
FA 55 CFM
VCD
FA 140 CFM
VCD
FA 140 CFM
VCD
FA 55 CFM
VCD
FA 140 CFM
VCD
FA 140 CFM
VCD
FA 140 CFM
EA 50 CFM
150X150 ECD
VCD
FA 55 CFM
VCD
FA 55 CFM
VCD
FA 140 CFM
VCD
FA 140 CFM
EA 115 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
SA 660 CFM EACH
450X450 SECD
900x400
900x400
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
EA 115 CFM
150X150 ECD
650X400SED
KED
TED
1150x600
FAD
390 CFM EACH
300X300 SECD
150 CFM
225X225 SAD/RAD
150 CFM
225X225 SAD/RAD
150 CFM
225X225 SAD/RAD
25 CFM
T/A
100 CFM
100 CFM
VENTILATION LAYOUT
V-04
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
FRESH AIR DUCT
VCD
VOLUME CONTROL DAMPER
EXHAUST AIR DIFFUSER
EXHAUST AIR DUCT
FA
FRESH AIR
EA
EXHAUST AIR
CFM
CUBIC FEET PER MINUTE
FD
FIRE DAMPER
SMD
SMOKE MOTORISED DAMPER
SED
SMOKE EXHAUST DUCT
EAG
EXHAUST AIR GRILL
FAHU
FRESH AIRHANDLING UNIT
SPF
STAIR CASE PRESSURIZATION FAN
MD
MOTORISED DAMPER
SEF
SMOKE EXHAUST FAN
EXF
EXHAUST FAN
NRD
NON RETURN DAMPER
SPD
STAIR CASE PRESSURIZATION DUCT
KEA
KITCHEN EXTRACT AIR
KED
KITCHEN EXHAUST DUCT
TEA
TOILET EXTRACT AIR
TOILET EXHAUST DUCT
TED
69
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
GYM FLOOR PLAN
A1 / 1:100
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
GYM FLOOR PLAN
PLOTLIMIT
R O A D 1 8 . 5 0 m
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 6
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 4
N E I G H B O U R P L O T 4 2 1 - 0 4 2 2\A1;30.48
\A1;45.72
\A1;30.48
\A1;45.72
PLOTLIMIT
PLOTLIMIT PLOTLIMIT
MALE GYM
F.F
TOILET
TOILET
WASH
CHANGING
FEMALE GYM
WASH
TOILET
TOILET
GSM
MECHANICAL ROOM
FEMALE GYM
CHANGING
DN
133132
121
122123
124
125
126
127128
129
130
131
135134
137
136 139
138
141
140 142
DN
157156 159158
161
160 163162 165
164
166
B
A
145
146
147148
149
150
151
152153
154
155
ELE.
MECHANICAL ROOF
MECHANICAL ROOF
MECHANICAL ROOF
MECHANICAL ROOF
F.F
CHANGING
LOCKERS
LOCKERS
MALE GYM
CHANGING
GYM EQUIPMENT
STORE
STAIR CASE PRESSURIZTION
600X200 SAG
450 CFM
SPD
750x400
SPD
750x400
STAIR CASE PRESSURIZTION
600X200 SAG
450 CFM
900x400
900x400
650X400
SED
KED
TED
1150x600
FAD
390 CFM EACH
300X300 SECD
FCU
H-M1
FCU
H-M2
FCU
H-K
FCU
H-02
FCU
H-01
FCU
H-F1
FCU
H-F2
VCD
FA 200 CFM
VCD
FA 200 CFM
VCD
FA 200 CFM
VCD
FA 200 CFM
VCD
FA 40 CFM
VCD
FA 220 CFM
VCD
FA 45 CFM
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
EA 50 CFM
150X150 ECD
SA 660 CFM EACH
450X450 SECD
300X300 SECD
390 CFM EACH
GE 200 CFM
GE 190 CFM
GE 200 CFM
25 CFM
T/A
V-02
VENTILATION LAYOUT
V-05
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
FRESH AIR DUCT
VCD
VOLUME CONTROL DAMPER
EXHAUST AIR DIFFUSER
EXHAUST AIR DUCT
FA
FRESH AIR
EA
EXHAUST AIR
CFM
CUBIC FEET PER MINUTE
FD
FIRE DAMPER
SMD
SMOKE MOTORISED DAMPER
SED
SMOKE EXHAUST DUCT
EAG
EXHAUST AIR GRILL
FAHU
FRESH AIRHANDLING UNIT
SPF
STAIR CASE PRESSURIZATION FAN
MD
MOTORISED DAMPER
SEF
SMOKE EXHAUST FAN
EXF
EXHAUST FAN
NRD
NON RETURN DAMPER
SPD
STAIR CASE PRESSURIZATION DUCT
KEA
KITCHEN EXTRACT AIR
KED
KITCHEN EXHAUST DUCT
TEA
TOILET EXTRACT AIR
TOILET EXHAUST DUCT
TED
70
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
ROOF FLOOR PLAN
A1 / 1:100
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
ROOF FLOOR PLAN
PLOTLIMIT
R O A D 1 8 . 5 0 m
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 6
N E
I G
H B
O U
R P
L O
T 4 2
1 -
0 4
2 4
N E I G H B O U R P L O T 4 2 1 - 0 4 2 2\A1;30.48
\A1;45.72
\A1;30.48
\A1;45.72
PLOTLIMIT
PLOTLIMIT PLOTLIMIT
LIFT ROOM
MECHANICAL ROOF
T/A
SPD
750x400
SPD
750x400
900x400
900x400
650X400
SED
KED
TED
FAD
GEF
400 CFM
NRD
EXHAUST LOUVERS
SPF-2
FRESH AIR GRILL
WITH WIRE MESH
MD
750x400
SPF-2
FRESH AIR GRILL
WITH WIRE MESH
MD
750x400
SMEF
EXHAUST GRILL
WITH WIRE MESH
MD
2325 CFM
VENTILATION LAYOUT
V-06
RETURN AIR DIFFUSER
SUPPLY AIR DIFFUSER
FRESH AIR DUCT
VCD
VOLUME CONTROL DAMPER
EXHAUST AIR DIFFUSER
EXHAUST AIR DUCT
FA
FRESH AIR
EA
EXHAUST AIR
CFM
CUBIC FEET PER MINUTE
FD
FIRE DAMPER
SMD
SMOKE MOTORISED DAMPER
SED
SMOKE EXHAUST DUCT
EAG
EXHAUST AIR GRILL
FAHU
FRESH AIRHANDLING UNIT
SPF
STAIR CASE PRESSURIZATION FAN
MD
MOTORISED DAMPER
SEF
SMOKE EXHAUST FAN
EXF
EXHAUST FAN
NRD
NON RETURN DAMPER
SPD
STAIR CASE PRESSURIZATION DUCT
KEA
KITCHEN EXTRACT AIR
KED
KITCHEN EXHAUST DUCT
TEA
TOILET EXTRACT AIR
TOILET EXHAUST DUCT
TED
71
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
FIRST FLOOR
+5.00
SECOND FLOOR
+8.35
GROUND FLOOR
+0.45
THIRD FLOOR
+11.70
FOURTH FLOOR
+15.05
FIFTH FLOOR
+18.40
GYM FLOOR
+21.75
ROOF FLOOR
FD
VCD
FD
VCD
FD
VCD
FD
VCD
FD
VCD
900 CFM
1350 CFM
1800 CFM
2250 CFM
2700 CFM
750x400
700x400
600x350
500x350
450x300
400X300
400x250
400x250
400x250
400x250
400x250
450 CFM
400x250
400X300
450 CFM
450 CFM
450 CFM
450 CFM
450 CFM
450 CFM
450 CFM
FD
VCD
FD
VCD
PRESSURIZATION UNIT
SPF-1
MD
3150 CFM
3150 CFM
850x400
FD
VCD
FD
VCD
FD
VCD
FD
VCD
FD
VCD
900 CFM
1350 CFM
1800 CFM
2250 CFM
2700 CFM
750x400
700x400
600x350
500x350
450x300
400X300
400x250
400x250
400x250
400x250
400x250
450 CFM
400x250
400X300
450 CFM
450 CFM
450 CFM
450 CFM
450 CFM
450 CFM
450 CFM
FD
VCD
FD
VCD
PRESSURIZATION UNIT
SPF-2
MD
3150 CFM
3150 CFM
850x400
V-07
SCHEMATIC DIAGRAM
STAIRCASE PRESSURIZATION
72
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
FIRST FLOOR
+5.00
SECOND FLOOR
+8.35
GROUND FLOOR
+0.45
THIRD FLOOR
+11.70
FOURTH FLOOR
+15.05
FIFTH FLOOR
+18.40
GYM FLOOR
+21.75
ROOF FLOOR
SMD
SMD
SMD
SMD
SMD
SMEF
SMOKE EXTRACT FAN
FIRE RATED FAN 2 HRS
MD
AS PER CIVIL DEFENCE
2325 CFM
650x400 SMOKE EXTRACT RISER
400X300
SMD
775 CFM
775 CFM
775 CFM
775 CFM
775 CFM
775 CFM
400X300
400X300
400X300
400X300
400X300
V-08
GARBAGE RISER DIAGRAM
SMOKE PRESSURIZATION &
73
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
FIRST FLOOR
+5.00
SECOND FLOOR
+8.35
GROUND FLOOR
+0.45
THIRD FLOOR
+11.70
FOURTH FLOOR
+15.05
FIFTH FLOOR
+18.40
GYM FLOOR
+21.75
ROOF FLOOR
FRESH AIR INTAKE
FAHU
EXTRACT AIR
SOUND.ATTN
THERMAL WHEEL
HEAT RECOVERY
SAND TRAP
EX. GRAVITY LOUVER
LOUVER
COOLING COIL
SUPPLY FAN
HEATING COIL
EXHAUST FAN
SOUND.ATTN
FRESH AIR DUCT
G FILTER
FD
VCD
805 CFM
400X300
4025 CFM
900x450
FD
VCD
805 CFM
400X300
3220 CFM
850x400
FD
VCD
805 CFM
400X300
2415 CFM
700x400
FD
VCD
805 CFM
400X300
1610 CFM
550x350
FD
VCD
3300 CFM
850x400
300 CFM
250x200
FD
VCD
3000 CFM
750x400
FD
VCD
2400 CFM
700x400
FD
VCD
1800 CFM
600x350
FD
VCD
1200 CFM
500x300
FD
VCD
805 CFM
400X300
805 CFM
400X300
FD
VCD
600 CFM
400x250
600 CFM
400x250
FD
45 CFM
VCD
200X100
45 CFM
200X100
FD
VCD
FD
VCD
FD
VCD
FD
VCD
FD
VCD
FD
8380 CFM
VCD
500x300
1060 CFM
1100x550
1500 CFM
550x350
2955 CFM
750x400
4410 CFM
900x450
5865 CFM
900x500
7320 CFM
1050x550
600 CFM
400x250
600 CFM
400x250
600 CFM
400x250
600 CFM
400x250
500x350
1455 CFM
500x350
500x350
500x350
500x350
1455 CFM
1455 CFM
1455 CFM
1455 CFM
V-09
RISER DIAGRAM
FRESH AIR & EHXAUST
74
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
TYPICAL FAN COIL UNIT INSTALLATION DETAIL
ANCHOR BOLTS
(TYPICAL)
FLEXIBLE DUCT CONNECTOR
ISOLATOR
VIBRATION
FLOOR/ROOF CONCRETE SLAB
{VARY}
ANY WALL
ACCESS
MINIMUM
DOOR
FCU
ACCESS DOOR
600 X 1000
VERIFY LOCATION
AIR FILTER
THREADED ROD HANGER
DROP FALSE CEILING
AIR FLOW
BAR SLIP
AIR FLOW
AIR FLOW
DRIVE SLIP
PLAIN S-SLIP
AIR FLOW
POCKET SLIP
AIR FLOW
AIR FLOW
REINFORCED BAR SLIP
ANGLE CONNECTION
TRANSVERSE JOINTS
R
S
IF REQUIRED
BEAD OR CROSSBREAK
W
VANE
STANDARD SEAMS OR
ANGLE REINFORCING
SEAM ON ALL
CORNERS
STANDARD RADIUSELBOW
ELBOW)
CORNERS
SEAMS ON ALL
R=W
W
R=W CENTER LINE R=1.5W
(ALSO CALLED FULL RADIUS
STANDARD RADIUS ELBOW DETAIL
SEE DUCT CONST. DET. FOR
SMALL ELBOW CONSTRUCTION
CONNECTIONS & BRACING
CONTRACTING FLOW
175 IN 300
30DEG. MAXIMUM ON
SEAM
SEAM
(R=W)
POSSIBLE
AIR FLOW
FULL RADIUS WHERE
TRANSITION & OFFSET
SEE DUCT CONSTRUCTION
300 ON DIVERGING
20DEG. MAXIMUM 100 IN
DETAIL FOR CONNECTUON
DAMPER
TRANSITION ELBOW
TRANSITION
3
2
1
W1
B =W1
W1 X D1
B X D1
A X D1
W2 X D2
MAIN BRANCH
FLOW
R=A+3/4 W3
A =
W3 X D3
(W3)(D3)
FOLLOWS;
(W2)(D2)+(W3)(D3)
R=3/4 W3
CONTROL ROD
( TYPICAL )
(W3)(D2)
WHEN CFM IS NOT LISTED, TRUNK MAY BE DIVIDED AS
(W2)(D2)+(W3)(D3)
SPLITER DAMPER BLADE
LENGHT EQUAL TO 3/4
WITH 6"MIN.(A=100 MIN.)
HINGE OR ROD
DUCT CONNECTION DETAIL
DETAIL FOR DUCTS PASSING THRU ROOF SLAB
50mm THICK PRECAST SLAB
FLASHING
SEALANT
RENDERED TYROLEAN
100mm BLOCKWORK
WATER PROOFING MEMBRANE
ALUMINIUM SHEET FLASHING
FAHU
MEP SPECIFICATION
VIBRATION ISOLATOR AS PER
MASTIC SEALANT
(2.0MT MIN)
150
ROOF SLAB
(IF REQUIRED)
GRILLE & PLENUM BOX.
ACOUSTIC DUCT LINER @3 METER LENGTH,
APLICABLE ONLY FROM THE FAN OUTLET,
NOTE :
*
*
3
10
9
6
7 8
1
2
4a
2a
5
9
6
7 8
1
2
4a
2a
5
9
87
6
5
4
3
2a2
1
& RETURN DUCT .
ROOF EXPOSED A/C SUPPLY
INDOOR A/C SUPPLY & RETURN DUCT
IN SHAFT & NON CONDENSING SPACE.
IN CONDENSING SPACE.
*
INDOOR A/C SUPPLY & RETURN DUCT
APPLICATION :
LEGEND :
ALUMINUM CLADDING
10
50x50x0.6mm G.I CORNER ANGLE
9
VAPOUR BARRIER SECOND COAT
8
7
F.G RIGID BOARD
SELF ADHESIVE PIN / HANGER
INSULATION / LINER ADHESIVE
G.I DUCTING
6
5
4a
4
3
2a
2
1
4a
2
1
4
7
8
9
10
5
6
2a
3
2
F.G FLEX. BLANKET
ALUMINUM SELF ADHESIVE TAPE
ACOUSTIC DUCT LINEAR
VAPOUR BARRIER FIRST COAT
CANVAS CLOTH
DUCT INSULATION & LAGGING DETAILS
AIR FLOW
%%USIDE ELEVATION
SIDE ELEVATION
SUCTION
LIQUID
SPRING VIBRATION
ISOLATOR
RIBBED RUBBER
PAD (TYP.)
DAMPER
AIR FLOW
4" MIN.
CONTROL PANEL
CONCRETE BASE PAD
%%UEND ELEVATION
END ELEVATION
CONDENSING UNIT FOUNDATION DETAILS
REFRIGERANT PIPE PENETRATION THRU ROOF
OAKUM PACKING
SILICON SEALANT
PIPE SLEEVE
STRUCTURAL ROOF
ROOF FINISHING
ROOFING MATERIAL
AS PER ARCH. DWG.
AS PER ARCH. DWG.
SILICON SEALANT
WATER PROOFING
FLASHING
THERMO FLEX INSULATION
REFRIGERANT PIPE
CLIP
HVAC GENERAL DETAILS
V-11 76
30/09/144210425239114-4-3
SHOULD NOT BE %%uCOPIED, REPRODUCED, OR
THIS IS THE SOLE AND EXCLUSIVE PROPERTY
OF %%U RIMAL ENGG. CONSULTANTS, DUBAI%%U. IT
FROM %%URIMAL ENGG. CONSULTANTS, DUBAI
THIS DRAWING SHOULD NOT BE PASSED ON
TO ANY OTHER PERSON OR USED FOR PURPOSES
OTHER THAN THOSE INTENDED AND AGREED.
WITHOUT THE PRIOR EXPRESS WRITTEN PERMISSION
%%UDUPLICATED IN ANY FORM OR BY ANY MEANS
DRG. No.:-
SHEET NO.:-
Checked :
Drawn : MOHD.RAHMATH
Scale :
Date : JAN 2014
Drawing Title :-
Job Title :-
Client :-
DO NOT SCALE DRAWINGS. FOLLOW WRITTEN DIMENSIONS
RevisionDateNo. Appr.
REVISION
engineering
rimal
consultant
Buhaleeba Plaza Building, Flat No.:201, \P P.O. Box: 39186, Deira, Dubai, U.A.E.\P Tel.: (04) 2681116, 2681117 Fax: (04) 2681188\P E-mail: [email protected] [email protected]
MOHAMMAD AHMAD THANI ATIQ ALFALASI
PLOT NO: 4210425 BLOCK:AL WARQA'A FIRST
PROPOSED GF+5+GYM+ROOF
RESIDENTIAL BUILDING
100
ISOLATOR
75 THK. CONC.PAD
OR BLOCK WALL
LIQUID LINE
CONCRETE UPSTAND
INSULATED SUCTION LINE
SLAB
2'-0"
6"
50 THK. ANTI VIBRATION
FINISH ROOF
RUBBER PAD
TYPICAL CONDENSING UNIT FOUNDATION DETAILS
TYPICAL REFRIGERANT PIPE & CONTROL DETAILS
CONCRETE FLOOR SLAB/ROOF SLAB
ANTI VIBRATION
F(MINIMUM 40x40mm)
SIZE TO SUIT WEIGHT OF
GALVANISED ANGLE.
MINIMUM 10mm%%C)
F HANGING DETAIL
GALVANISED THREADED ROD
(SIZE AS PER THE WEIGHT
DETAIL 'B'
(AS SPECIFIED)
ISOLATOR
LOCKING NUT
F CASING
WASHER
F
SEE DETAIL 'B'
INSERT
EXPANSION ANCHOR
DUCT OPENING - WALL CROSSING DETAIL
FINNISH OR EPOXED AREA
STD. ESTCHEONS IN
20%%Cmm WOODEN
FRAME ALL AROUND
DUCT INSULATION
AIR DUCT
WALL
DUCT H=?
METAL SCREW W/ FISHER
MASTIC SEALANT ALL AROUND
D=?
TYPICAL RETURN AIR CEILING DIFFUSER,WALL GRILL DETAIL
INTERNAL LINING
REFRIGERANT PIPES SUPPORT DETAIL
STANDARD(MINIMUM 25x25mm)
THERMAL INSULATION AS SPECIFIED
GALVANISED THREADED ROD
INSULATION (AS REQUIRED)
RIGID SECTION (HARD RUBBER/CORK/POLYSTYRENE)
GI ANGLE AS PER ASHRAE/SMACNA
DUCTWORK SUPPORT DETAIL
DIMENSION
STATED DUCT
STATED DUCT
DIMENSION
AT DUCT SUPPORT
LOCK NUTS & WASHERS
25mm THICK ACCOUSTIC
DUCT WALL
NUT & WASHER
EXPANSION ANCHOR
TYPICAL DETAIL FOR STAIRCASE PRESSURIZATION FAN
FLEXIBLE CONNECTION
BIRD SCREEN
BELL MOUTH
FAN
MD
MAXIMUM HANGER SPACING
2 - 1/8
1 - 1/8
1 - 3/8
1 - 5/8
INCHES O.D.
1/2 - 5/8
3/4 - 7/8
SIZE TUBING
10
FT.
MAXIMUM SPAN
PIPES WITH FIXING CLAMP
HORIZANTAL RUN OF REF.
FINISHES TO BE AS PER
HDGI TRAYS FOR
REFRI. PIPES
FICING BOLTS
CABLE TRAY COVER
SPECIFICATION.
ROOF SLAB
I BEAM
ON/OFF ISOLATOR
FROM CONDENSER UNIT
CONTROL CABLES TO FCU
FCU
LIQUID/SUCTION
REFRIGERANT LINE
ON ROOF TOP
W P ISOLATORCU
EXTRACT AIR AXIAL FAN DETAIL ROOF MOUNTED
AIR
FLOW
ROOF
FLOW
AIR
3mm. THICK
15x15CM STEEL PLATE
(BOTH SIDES)
ANGLE SUPPORT
FLEXIBLE CONNECTION
BOLT
MOTOR
CURB
CONNECT DUCTWORK TO FAN
WITH 1/8" THICK NEOPRENE
DUCTWORK
FRESH AIR INTAKE LOUVER WITH,
(MOUNTING BRACKET)
ALLUMUNIUM FILTER 20 MM
COOLING COIL
SUPPLY FAN
INTAKE
FRESH AIR
THERMAL WHEEL
EXHAUST FAN
HEAT RECOVERY
SAND TRAP LOUVRE
FLAT FILTER
BAG FILTER
TREATED FRESH
AIR SUPPLY
EX. GRAVITY LOUVER
EX AIR
EX. AIR
TYPICAL FRESH AIR HANDLING UNIT
FRESH AIR HANDLING UNIT BASE
AND ENGINEER'S APPROVAL.
AS PER MEP SPECIFICATION
VIBRATION ISOLATOR
150mm
AS PER ARCHITECTURAL LAYOUTS.
WATER PROOFING DETAILS SHALL BE
DRAIN CONDENSATE PIPE
TOTAL FAN STATIC
PRESSURE.
DRAIN
FALL TO NEAREST
TO BE LESS THAN THE
THIS DIMENSION NOT
U-TRAP
FRESH AIR HANDLING UNIT
R.C.C. INTEGRAL TO FLOOR
SLAB AS PER STRUCTURAL
HVAC GENERAL DETAILS
V-10 75
30/09/144210425239114-4-3