11
HV/MV SWITCHGEAR Products Vol. 03

03 H SWITCHGEAR - Skemaqpressrelease.skemaq.it/wp-content/uploads/2017/11/HV-MV...AIR INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR 08 09 11 HV/MV CASE STUDIES SKEMA IS A GLOBAL MARKET

  • Upload
    others

  • View
    21

  • Download
    2

Embed Size (px)

Citation preview

  • HV/MV SWITCHGEAR

    Prod

    ucts

    Vol

    . 03

  • HV/MV SWITCHGEARWHY CHOOSE SKEMA - ---------------------------------- 04GENERAL FEATURES - ------------------------------------- 06AIR INSULATED SWITCHGEAR - ---------------- 08GAS INSULATED SWITCHGEAR - -------------- 09HV/MV CASE STUDIES ---------------------------------- 10

    CONTENTS

  • WHY CHOOSE SKEMA THE MAIN ADVANTAGES FOR CHOOSING SKEMA ARE:

    1 FLEXIBILITY AND PERSONALIZATION: FLEXIBLE MANUFACTURING IN ALL THE STAGES OF THE PROJECT TO IMPLEMENT OUR CLIENTS’ SPECIAL REQUIREMENTS

    2 OPTIMIZATION OF DELIVERY LEAD TIMES: FROM ENGINEERING TO FINAL COMMISSIONING AND MODIFICATIONS

    3 SERVICE AND CUSTOMER CARE: RAPID RESPONSE, EXPERT TECHNI-CAL SUPPORT, COMPREHENSIVE AFTER SALES SERVICE (ON SITE AND FROM HEADQUARTER)

    4 “ONE STOP SHOP”: SKEMA CAN SUPPLY HV/MV SWITCHGEAR AND MODULAR SUBSTATIONS, LV SWITCHGEAR AND IPCS SYSTEMS

    5 EXPERIENCE: PROVEN TRACK RECORD IN INTERNATIONAL CAPITAL PROJECTS IN THE OIL AND GAS INDUSTRY FOR COMPLEX PACKAGES

    0504

  • GENERAL FEATURES

    WITH REFERENCE TO HV/MV SWITCH-

    GEAR, SKEMA OPERATES ON A “PRO-

    JECT SPECIFIC” APPROACH, WHICH

    TAKES INTO ACCOUNT THE CLIENT’S

    SPECIFIC REQUIREMENTS AND THE

    PROJECT SPECIFICATIONS.

    Skema can supply the main power

    section of the major original equip-

    ment manufacturers worldwide, and

    complete and personalize the aux-

    iliary and LV compartment, includ-

    ing the exhaust gas duct, all doors,

    external structures and copper details.

    Skema’s HV/MV switchgear are de-

    signed and manufactured in accord-

    ance to IEC 62271-200 and to the fol-

    lowing requirements:

    > Maximum operational reliability

    > Compact dimensions

    > Flexibility and versatility

    > Easy installation, function and

    maintenance

    > Personnel safety

    > Possibility of extensions and mod-

    ifications

    Skema’s HV/MV switchgear can be

    provided with sulphur hexafluor-

    ide (SF6) circuit breakers, vacu-

    um circuit breakers and/or vac-

    uum contactors, and they are

    arc-proof, so they can be installed

    and used in areas characterized by

    extreme ambient conditions. 06 07

  • RATED VOLTAGE 7.2 kV 12 kV 17.5 kV 24 kV

    ELECTRICAL FEATURES

    Rated power frequency withstand voltage 20 kV 28 kV 38 kV 50 kV

    Impulse withstand voltage 60 kV 75 kV 95 kV 120 kV

    Rated frequency 50 /60 Hz 50 /60 Hz 50 /60 Hz 50 /60 Hz

    Rated short-time withstand current Up to 50 kA3s

    Up to 50 kA3s

    Up to 50 kA3s

    Up to 31.5 kA3s

    Peak withstand current Up to 125 kA Up to 125 kA Up to 125 kA Up to 80 kA

    Internal arc withstand current Up to 50 kA1s Up to 50 kA1s Up to 50 kA1sUp to 31.5 kA1s

    Rated current of the main busbars 4000 A 4000 A 4000 A 3150 A

    Feeders rated current with natural ventilation 630÷3150 A 630÷3150 A 630÷3150 A Up to 2300 A

    Branch connection rated current with forced ventilation 3600 /4000 A 3600 /4000 A 3600 /4000 A -

    MECHANICAL FEATURES

    Partition class PM PM PM PM

    Service continuity category LSC-2B LSC-2B LSC-2B LSC-2B

    Internal arc classification IAC AFLR IAC AFLR IAC AFLR IAC AFLR

    Construction Withdrawable Withdrawable Withdrawable Withdrawable

    Circuit Breaker Vacuum/SF6 Vacuum/SF6 Vacuum/SF6 Vacuum/SF6

    External protection degree IP4X/ IP41/IP42

    IP4X/ IP41/IP42

    IP4X/ IP41/IP42

    IP4X/ IP41/IP42

    Internal protection degree IP20 IP20 IP20 IP20

    Internal partitions (on request) IP3X IP3X IP3X IP3X

    Cable access Front Front Front Front

    Cable entry Top-bottom Top-bottom Top-bottom Top-bottom

    Installation Indoor Indoor Indoor Indoor

    RATED VOLTAGE 12 kV 17.5 kV 24 kV 36 kV

    ELECTRICAL FEATURES

    Power frequency withstand voltage 28 kV 38 kV 50 kV 70 kV

    Lighting impulse withstand voltage 75 kV 95 kV 125 kV 170 kV

    Rated frequency 50 /60 Hz 50 /60 Hz 50 /60 Hz 50 /60 Hz

    Rated short-time withstand current Up to 31.5 kA3s

    Up to 31.5 kA3s

    Up to 31.5 kA3s

    Up to 31.5 kA3s

    Peak withstand current Up to 80 kA Up to 80 kA Up to 80 kA Up to 80 kA

    Rated current of the main busbars Up to 2500 A Up to 2500 A Up to 2500 A Up to 2500 A

    Insulating Gas SF6 SF6 SF6 SF6

    MECHANICAL FEATURES

    Partition class PM PM PM PM

    Gas-filled compartmentsLoss of service continuity N.A. N.A. N.A. N.A.

    Cable termination compartmentsLoss of service continuity LSC-2B LSC-2B LSC-2B LSC-2B

    Construction Fixed Fixed Fixed Fixed

    Circuit Breaker Vacuum Vacuum Vacuum Vacuum

    High Voltage compartments protection degree IP65 IP65 IP65 IP65

    Low Voltage compartments protection degree IP4X IP4X IP4X IP4X

    Cable access Rear Rear Rear Rear

    Cable entry Bottom Bottom Bottom Bottom

    Maximum site altitude 1000 m 1000 m 1000 m 1000 m

    Installation Indoor Indoor Indoor Indoor

    AIR INSULATED SWITCHGEAR GAS INSULATED SWITCHGEAR

    0908

  • 11

    HV/MV CASE STUDIES SKEMA IS A GLOBAL MARKET LEADER IN THE DESIGN, ENGINEERING, MANUFACTURE AND SERVICING OF COMPLETE PACKAGES, INCLUD-ING HV/MV SWITCHGEAR, LV SWITCHGEAR AND IPCS SYSTEMS. SKEMA’S HV/MV SWITCH-GEAR ARE DESIGNED FOR USE IN HV/MV AND MV/LV SUBSTATIONS AND FOR HIGHLY DEMANDING APPLICATIONS. SKEMA COUNTS IN ITS PROJECTS’ PORTFOLIO A PROVEN TRACK RECORD IN THE SUPPLY OF HV/MV SWITCH-GEAR FOR A WIDE VARIETY OF PROJECTS, BOTH AS PART OF COMPLETE PACKAGES AND AS STAND-ALONE SUPPLIES.

    1110

  • KAZAKHSTAN KAZAKHSTAN

    CHINAREVSKOYEFIELD / KAZAKHSTAN ONSHORE

    ESKENE WEST RAIL /

    KAZAKHSTAN ONSHORE

    UzbekistanCaspian Sea

    Kyrgyzstan

    UzbekistanCaspian Sea

    Kyrgyzstan

    AIR INSULATED SWITCHGEAR

    Rated voltage: 7.2 kVService voltage: 6.0 kVRated power frequency withstand voltage: 20 kV Impulse withstand voltage: 60 kV Rated frequency: 50 HzRated current of the main busbars: 2500 ARated short-time withstand current: 40 kA1sPeak withstand current: 100 kAInternal arc withstand current: 40 kAArc fault duration: 1 secCopper busbar system: BareExternal protection degree: IP40Internal protection degree: IP2XPainting: RAL 7035Design ambient temperature: +40°C

    AIR INSULATED SWITCHGEAR

    Rated voltage: 12 kV Service voltage: 10 kVRated power frequency withstand voltage: 28 kVImpulse withstand voltage: 75 kV Rated frequency: 50 HzRated current of the main busbars: 1250 ARated short-time withstand current: 25 kA1sPeak withstand current: 63 kAInternal arc withstand current: 25 kAArc fault duration: 1 secCopper busbar system: InsulatedExternal protection degree: IP41Internal protection degree: IP2XPainting: RAL 7035Design ambient temperature: -5°C /+42°C

    12 13

  • KARACHAGANAK / KAZAKHSTAN ONSHORE

    SCP EXPANSION / AZERBAIJAN

    AND GEORGIA ONSHORE

    GEORGIA Caspian Sea

    Turkey

    IranIraq

    Syria

    Black Sea

    KAZAKHSTAN

    AZERBAIJAN

    UzbekistanCaspian Sea

    Kyrgyzstan

    AIR INSULATED SWITCHGEAR

    Rated voltage: 12 kVService voltage: 6.0 kV Rated power frequency withstand voltage: 28 kVImpulse withstand voltage: 75 kVRated frequency: 50 HzRated current of the main busbars: 2500/630 ARated short-time withstand current: 25/20 kA1sPeak withstand current: 63/50 kAInternal arc withstand current: 25/20 kAArc fault duration: 1 secCopper busbar system: BareExternal protection degree: IP3XInternal protection degree: IP2XPainting: RAL 7035 and 9002Design ambient temperature: -5°C /+40°C

    AIR INSULATED SWITCHGEAR

    Rated Voltage: 12 kVService voltage: 10 kVRated power frequency withstand voltage: 28 kV Impulse withstand voltage: 75 kV Rated frequency: 50 HzRated current of the main busbars: 630 ARated short-time withstand current: 25 kA1sPeak withstand current: 63 kAInternal arc withstand current: 25 kAArc fault duration: 1 secCopper busbar system: InsulatedExternal protection degree: IP42Internal protection degree: IP3XPainting: RAL 7032Design ambient temperature: -5°C /+40°C

    14 15

  • TENGIZ / KAZAKHSTAN ONSHORE

    SURINAME

    Brazil

    Bolivia

    TOUT LUI FAUT REFINERY / SURINAME

    ONSHOREKAZAKHSTAN

    GuyanaFrench Guiana

    Paraguay

    UzbekistanCaspian Sea

    Kyrgyzstan

    AIR INSULATED SWITCHGEAR

    Rated voltage: 7.2/17.5 kVService voltage: 6.0/12.3 kVRated power frequency withstand voltage: 20/38 kVImpulse withstand voltage: 60/95 kV Rated frequency: 60 HzRated current of the main busbars: 1600/1250 ARated short-time withstand current: 40/31.5 kA1sPeak withstand current: 104/82 kAInternal arc withstand current: 40/31.5 kAArc fault duration: 1 secCopper busbar system: BareExternal protection degree: IP41Internal protection degree: IP2X Painting: RAL 6029Design ambient temperature: -5°C /+40°C

    AIR INSULATED SWITCHGEAR

    Rated voltage: 7.2 kVService voltage: 6.0 kVRated power frequency withstand voltage: 20 kV Impulse withstand voltage: 60 kVRated frequency: 50 HzRated current of the main busbars: 1250 ARated short-time withstand current: 20 kA1sPeak withstand current: 50 kAInternal arc withstand current: 20 kAArc fault duration: 1 secCopper busbar system: BareExternal protection degree: IP4XInternal protection degree: IP2X Painting: RAL 7035Design ambient temperature: -5°C /+40°C

    GAS INSULATED SWITCHGEAR

    Bus bar arrangement: Single bus barService voltage: 35 kV Rated voltage: 36 kVImpulse withstand voltage: 170 kVRated power frequency withstand voltage: 70 kV Rated frequency: 50 HzRated current of the main busbars: 1250 ARated short-time withstand current: 25 kA1sPeak withstand current: 63 kAInternal arc withstand current AFLR: 25 kAArc fault duration: 1 secHV compartments protection degree: IP65LV compartments protection degree: IP4XPainting: RAL 7035Design ambient temperature: -5°C / +40°C