5
SURPASS hiD 6615 S411 Compact Chassis Gigabit Ethernet Switch SURPASS hiD 6615 S411 is a compact chassis type L3 Gigabit Ethernet switch. It is a module type of switch and can be equipped with several modules (units) in the chassis. It effectively utilizes both front and rear side of the chassis for holding modules. The hiD 6615 S411 is a shelf- based modular switch so that user can customize it for your network circumstance. It adopts redundancy structure you can make up for have them all in the shelf or you can equip the redundant SFU, power, fan units in for reliable operation. The hiD 6615 S411 is composed of a chassis and several pluggable modules. The chassis have midplane and Management Interface Unit (MIU) as fixed system components. The following lists the supported interface units of the switch. Optical Interface Unit (OIU) for Gigabit Ethernet service 10-Gigabit Ethernet Interface Unit (XIU) Switching Fabric Unit (SFU) Power Supply Units (PSU) Fan Units This product is specially designed to fit in rural areas with long distance to provide them broadband access. It features power, fan, and switching fabric redundancy, so stable operation could be achieved from sudden network failure. Also, it is the most economical aggregation switch that consolidates traffic from various sources in an access network and uplinks to the edge router with 48 Gigabit Ethernet ports. Service providers can deploy Gigabit Ethernet service over the existing DSL infrastructure or access networks. With performance of a non-blocking switching capacity of up to 176 Gbps switching capacity and 101 Mpps throughput, the hiD 6615 S411 provides high speed networking environment.

01-4NSN_DS_hiD6615_S411

Embed Size (px)

DESCRIPTION

nsn dslam

Citation preview

Page 1: 01-4NSN_DS_hiD6615_S411

SURPASS hiD 6615 S411 Compact Chassis Gigabit Ethernet Switch

SURPASS hiD 6615 S411 is a compact chassis type L3 Gigabit Ethernet switch. It is a module type of switch and can be equipped with several modules (units) in the chassis. It effectively utilizes both front and rear side of the chassis for holding modules.

The hiD 6615 S411 is a shelf-based modular switch so that user can customize it for your network circumstance. It adopts redundancy structure you can make up for have them all in the shelf or you can equip the redundant SFU, power, fan units in for reliable operation. The hiD 6615 S411 is composed of a chassis and several pluggable modules. The chassis have midplane and Management Interface Unit (MIU) as fixed system components. The following lists the supported interface units of the switch. • Optical Interface Unit (OIU) for Gigabit Ethernet service • 10-Gigabit Ethernet Interface Unit (XIU) • Switching Fabric Unit (SFU) • Power Supply Units (PSU) • Fan Units

This product is specially designed to fit in rural areas with long distance to provide them broadband access. It features power, fan, and switching fabric redundancy, so stable operation could be achieved from sudden network failure. Also, it is the most economical aggregation switch that consolidates traffic from various sources in an access network and uplinks to the edge router with 48 Gigabit Ethernet ports. Service providers can deploy Gigabit Ethernet service over the existing DSL infrastructure or access networks. With performance of a non-blocking switching capacity of up to 176 Gbps switching capacity and 101 Mpps throughput, the hiD 6615 S411 provides high speed networking environment.

Page 2: 01-4NSN_DS_hiD6615_S411

Copyright 200X Nokia Siemens Networks. All rights reserved. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. XXX, XXX and XXX are trademarks or registered trademarks of Nokia Siemens Networks Corporation (if there are other trademarks included in the material). www.nokiasiemensnetworks.com

Overview

In the front, hiD 6615 S411 has three service interface slots. OIU could be inserted into two slots from the top. The bottom is divided into two half slots. The left half is for the MIU and the right half is for the XIU or blank unit if you don’t want to use. XIU delivers high bandwidth and low latency, which could make an uplink connection to core network by using two 10 GE trunk ports.

Figure – hiD 6615 S411 System Architecture

In the rear, there are two SFU slots from the top and two PSU slots in the bottom. A pair of SFU and PSU slot is incorporated for redundancy; a SFU and PSU can operate alone without redundant one. Or, by using redundant SFUs and PSUs, the switch can perform stable switching operation and power feeding. The switch has four fan units in total. They are located vertically at both ends in the front and rear side of chassis. The air flows from the right side inlet to the left side outlet. A fan unit can run in any different fan slot.

The hiD 6615 S411 is a network element, which includes the necessary service adaptation functions to support multiple services, such as Ethernet, IP telephony, and video services over broadband. The hiD 6615 S411 is a middle class aggregation switch. It performs all the necessary L2/L3 functions as normal carrier Ethernet switches do. Also, it concentrates traffic originated from DSL or access infrastructures through its Gigabit Ethernet ports and carries fast traffic delivery to the uplink core network with its 10 Gigabit Ethernet ports. The hiD 6615 S411 can be managed with Access Integrator Ethernet (ACI-E) EM DX R3.0, which is the element manager for all NEs from Nokia Siemens Networks carrier Ethernet solution. It enables the operators to benefit from the whole feature set supported by the products. ACI-E EM DX R3.0 supports FCAPS-functionality (fault management, configuration management, accounting management, performance management and security management). Mass provisioning tables, topological maps and wide network alarm tables are further value added services that facilitates operators’ daily work.

Midplane

SFUSFU

OIU

OIU

XIU

MIU

PSU

10G x 2

1G x 24

1G x 24

Cosole Mgmt

PSU

hiD 6615 S411

FAN Units

FAN Units

OIU MIU

SFU

Blank / XIU

PSU

FAN Units

Front

Rear

Page 3: 01-4NSN_DS_hiD6615_S411

Copyright 200X Nokia Siemens Networks. All rights reserved. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. XXX, XXX and XXX are trademarks or registered trademarks of Nokia Siemens Networks Corporation (if there are other trademarks included in the material). www.nokiasiemensnetworks.com

Specifications

System

• 136 Gbps switching capacity and 100 Mpps throughput • 2 switching fabric units for redundancy • 2 line card slots: – 24 port 100/1000Base-X SFP per line card x 2 slots • Redundant power supply unit (PSU) • Redundant and Hot swappable 4 FANs • SFP module hot swappable • Visual LED alarm indicator • 2 MB packet buffer size Network Interfaces

• Each OIU contains 24 service slots for SFP modules providing optical FE/GE interface: – 24 x Ethernet 100/1000Base-X interface IEEE 802.3z compliant Subscriber Interfaces

• Console command line interface (CLI) via RS232 • Outband management via 100Base-T • Inband management (SNMPv1/v2/v3)

Functionalities • 32K MAC entries • VLAN stacking/translation • Spanning tree (STP, RSTP, and MSTP) • Ethernet ring protection (ERP) • Jumbo frame 9K • 12K routing entries • RIPv1/v2 • OSPFv2 • BGPv4 • VRRP • IGMPv1/v2/v3 • 1K L2 multicast entries • 2K L3 multicast entries • IGMP snooping/proxy/static join • MVR • PIM-SM/SSM • Traffic policing and shaping • 8 queues per port • Traffic scheduling (SP, WRR, DRR) • Conditional rate limiting • Storm control • SSH • 802.1x port/MAC based authentication • IP source guard • Port / MAC / Ether type / L4-based ACL(Access Control List) • DoS protection • Outband management • SNMPv1/v2/v3 • DHCP server, client, relay agent with Option82 • RMON • Syslog

Page 4: 01-4NSN_DS_hiD6615_S411

Copyright 200X Nokia Siemens Networks. All rights reserved. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. XXX, XXX and XXX are trademarks or registered trademarks of Nokia Siemens Networks Corporation (if there are other trademarks included in the material). www.nokiasiemensnetworks.com

Technical Data

Mechanics Number of slots 12 Dimensions (W x H x D) 440 mm x 132.5 mm x 335 mm Minimum free space above shelf 50 mm Minimum free space below shelf 25 mm Heat transfer: Air inlet − on the right fan of the shelf Air outlet − on the left fan of the shelf

Environmental Conditions Operating temperature 0 to +50 °C Storage temperature −20 to +60 °C Operating humidity 0 to 90 % (non-condensing)

Power Supply DC power voltage −48/60 V AC power voltage 100 to 240 V 50/60 Hz

Interface Parameter Ethernet i/f (optical) 100/1000Base-X (SFP) Ethernet i/f (electrical) 10/100/1000Base-T (RJ45) Ethernet i/f for local management 10/100Base-T (RJ45) Serial i/f, Console RS232

Page 5: 01-4NSN_DS_hiD6615_S411

Copyright 200X Nokia Siemens Networks. All rights reserved. Nokia is a registered trademark of Nokia Corporation. Siemens is a registered trademark of Siemens AG. XXX, XXX and XXX are trademarks or registered trademarks of Nokia Siemens Networks Corporation (if there are other trademarks included in the material). www.nokiasiemensnetworks.com

Plug-in Unit Description

SFU Switch fabric unit, 176 Gbps switching capacity

OIU 2 optical GE blank for SFPs, front-access

TIU 2 electrical GE ports, front-access

PSU-DC DC power connector and fuse

PSU-AC AC power connector and fuse

MIU Management interfaces; console, MGMT, and LEDs

FAN Unit Fan unit

Figure – Front View of hiD 6615 S411

Figure – hiD 6615 S411Slot Allocation

Design

FAN Unit B(front)

OIU

OIU

MIU BLANK Slot

Slot 1

Slot 2

FAN Unit A(front)

FAN Unit A(rear)

FAN Unit B(rear)

SFU A

SFU B

PSU A PSU B