    M900/M1800 Base Station Controller

    Initial Configuration Manual Contents

    Issue 07 (2006-08-20) Huawei Technologies Proprietary i

    Contents

    4 Local Office Data........................................................................................................................4-7

    4.1 Overview.......................................................................................................................................................4-8

    4.2 Configuring Local Office Information ........................................................................... ...............................4-8

    4.1.1 Configuring Network Property............................................................................................................4-8

    4.2.2 Configuring Location Property .......................................................................... ..................................4-9

    4.2.3 Configuring Interface Property ................................................................. .........................................4-10

    4.3 Configuring System Property......................................................................................................................4-11

    4.1.1 Configuring Alarm Parameter Table ..................................................................... ............................ 4-11

    4.3.2 Configuring Semi-permanent Connection ................................................................. ........................4-12

    4.3.3 Configuring BTS Software Index ...................................................................... ................................4-13

    4.3.4 Configuring Common Parameter Table ...................................................................... .......................4-14

    4.3.5 Configuring Flow Control..................................................................................................................4-18

    4.3.6 Configuring Reserved Parameter ..................................................................... ..................................4-19

    4.4 Loading Board Software .......................................................... ................................................................... 4-20

    4.5 Configuring BSC BIE Semi-perm. Con. .......................................................... ...........................................4-21

    4.6 Configuring Advanced Property..................................................................................................................4-22

    4.6.1 Configuring SS7.................................................................................................................................4-22

    4.6.2 Configuring Other Properties.............................................................................................................4-24

    4.6.3 Configuring A Interface Timeslot Occupies..................................... .................................................. 4-25

    4.6.4 Configuring Timer Data.....................................................................................................................4-26

    4.7 Confirming Modification .................................................................. .......................................................... 4-27

  • 7/28/2019 01-4 Local Office Data.pdf

    2/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual Figures

    Issue 07 (2006-08-20) Huawei Technologies Proprietary iii

    Figures

    Figure 4-1 [Local Office Information] tab page ...................................................................... ...........................4-8

    Figure 4-2 Configure network property..............................................................................................................4-9

    Figure 4-3 Configure location property............................................................................................................4-10

    Figure 4-4 Configure interface property...........................................................................................................4-10

    Figure 4-5 Configure system flow control property.........................................................................................4-11

    Figure 4-6 Password verification......................................................................................................................4-11

    Figure 4-7 Alarm Parameter Table .................................................................. ................................................. 4-12

    Figure 4-8 Semi-permanent Connection Table.................................................................................................4-13

    Figure 4-9 BTS Software Configuration ...................................................................... ....................................4-13

    Figure 4-10 Add Configuration Item................................................................................................................4-14

    Figure 4-11 configure common parameter .............................................................. .........................................4-15

    Figure 4-12 configure soft parameter ........................................................... .................................................... 4-16

    Figure 4-13 Module description table .............................................................. ................................................ 4-17

    Figure 4-14 Password verification....................................................................................................................4-18

    Figure 4-15 Set Flow Control Table ................................................................. ................................................ 4-19

    Figure 4-16 Reserved Parameter Configuration...............................................................................................4-20

    Figure 4-17 BSC Board Software Loading Table.............................................................................................4-21

    Figure 4-18 Add BSC Board Software Loading Information...........................................................................4-21

    Figure 4-19 BSC BIE Semi-perm. Conn..........................................................................................................4-22

    Figure 4-20 [SS7 Signaling] tab page...............................................................................................................4-23

  • 7/28/2019 01-4 Local Office Data.pdf

    3/25

    Figures

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    iv Huawei Technologies Proprietary Issue 07 (2006-08-20)

    Figure 4-21 Others properties...........................................................................................................................4-24

    Figure 4-22 A Interface Timeslot Occupies......................................................................................................4-26

    Figure 4-23 Timer Data .................................................................. .................................................................. 4-26

  • 7/28/2019 01-4 Local Office Data.pdf

    4/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual Tables

    Issue 07 (2006-08-20) Huawei Technologies Proprietary v

    Tables

    Table 4-1 Description of the parameters related to network property configuration ..........................................4-9

    Table 4-2 Description of the parameters related to location property configuration. .......................................4-10

    Table 4-3 Description of the parameters related to interface property configuration. ...................................... 4-11

    Table 4-4 Meaning of soft parameter................................................................................................................4-16

    Table 4-5 Description of the parameters...........................................................................................................4-18

    Table 4-6 Description of the parameters in [SS7 Signaling].............................................................................4-23

    Table 4-7 Description of the parameters in [Others].........................................................................................4-24

  • 7/28/2019 01-4 Local Office Data.pdf

    5/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-1

    4 Local Office Data

    About This Chapter

    The following table lists the contents of this chapter.

    Title Description

    4.1 Overview Introduces the main idea of this chapter.

    4.2 Configuring Local OfficeInformation Describes the procedure for configuring the local officeinformation.

    4.3 Configuring SystemProperty

    Describes the procedure for configuring the systemproperty.

    4.4 Loading Board Software Describes the procedure for loading the board software.

    4.6 Configuring AdvancedProperty

    Describes the procedure for configuring the advancedproperty.

    4.7 Confirming Modification Describes the procedure for confirming modification.

  • 7/28/2019 01-4 Local Office Data.pdf

    6/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-2 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    4.1 Overview

    BSC local office data configuration is of great significance, and has direct impact upon the

    normal operation of the GMPUs in BSC.

    BSC local office information describes SS7 information in BSC, e.g., OPC, DPC, SCCP, etc.

    And the GSM specification supported by each interface (A/Abis/Um interface).

    4.2 Configuring Local Office Information

    Select the [Local Office Information] tab page in BSC Auto Data Configuration System, asshown in Figure 4-1.

    Figure 4-1[Local Office Information] tab page

    4.1.1 Configuring Network Property

    Configure network property, as shown in Figure 4-2.

  • 7/28/2019 01-4 Local Office Data.pdf

    7/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-3

    Figure 4-2Configure network property

    See Table 4-1 for the description of the parameters related to network property configuration.

    Table 4-1Description of the parameters related to network property configuration

    Parameter name Default

    value

    Description

    Signaling NetworkIndicator

    NationalStandby

    As per the actual conditions, configure thesignaling network that OSP belongs to.

    BSC Signaling PointCode

    None Namely, OPC. Configure this parameter as perthe network plan.

    MSC Signaling PointCode

    None Namely, DPC. Configure this parameter as perthe data in the peer MSC.

    z All the SPCs of Huawei GSM equipment is indicated by hexadecimal. Please convert the SPCs if

    there are indicated by decimal digits in relevant documents. Generally, SPC is a 14-bit signaling

    code, and may be a 24-bit signaling code. To meet the various requirements of different MSCs, SPCshould be configured based on negotiation.

    z When signaling abnormality occurs, user can check whether the first digit of hexadecimal in SPC is

    "0", and can attempt to add "0" to or remove "0" from the first digit. "0" will change the valid bitnumber of SPC, the method to identify the number of SPC is different between different MSC.

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

    4.2.2 Configuring Location Property

    Configure location property, as shown in Figure 4-3.

  • 7/28/2019 01-4 Local Office Data.pdf

    8/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-4 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    Figure 4-3Configure location property

    See Table 4-2 for the description of the parameters related to location property configuration.

    Table 4-2Description of the parameters related to location property configuration.

    Parameter name Defaultvalue

    Description

    Country Code None Namely, CC, the country code registered by MS. Forexample, the CC of China is "86".

    Mobile CountryCode

    None Namely, MCC, uniquely identifying the country that

    MS belongs to. For example, the MCC of China is"460".

    Local Area Code None Toll call area code for the area where BSC is located.

    Mobile Network

    Code

    None Namely, MNC, identifying the PLMN that MS belongs

    to.

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

    4.2.3 Configuring Interface Property

    Configure interface property, as shown in Figure 4-4.

    Figure 4-4Configure interface property

    See Table 4-3 for the description of the parameters related to interface property configuration.

  • 7/28/2019 01-4 Local Office Data.pdf

    9/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-5

    Table 4-3Description of the parameters related to interface property configuration.

    Parameter name Default value Description

    A Interface Version GSM_Phase_2 Select an interface version as per the GSM

    protocol criterion which is adopted by the Ainterface provided by MSC.

    Abis InterfaceVersion

    GSM_Phase_2 None

    Um Interface Version GSM_Phase_2 None

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

    4.3 Configuring System Property

    Configure system property, as shown in Figure 4-5.

    Figure 4-5Configure system flow control property

    4.1.1 Configuring Alarm Parameter Table

    In Figure 4-5, click , The interface will pop up as shown in Figure 4-6.

    Figure 4-6Password verification

    Input supervisor password, and click , the interface will pop up as shown in Figure 4-7.

  • 7/28/2019 01-4 Local Office Data.pdf

    10/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-6 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    Figure 4-7Alarm Parameter Table

    Modify the parameters of alarm.

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

    4.3.2 Configuring Semi-permanent Connection

    The semi-permanent connection is to provide a transport path with the bandwidth of 64 kbit/s

    for customer. It is used to transmit business hall information, BTS AC power alarminformation and other maintenance information.

    Click in Figure 4-5, the interface will pop up as shown in Figure 4-8.

  • 7/28/2019 01-4 Local Office Data.pdf

    11/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-7

    Figure 4-8Semi-permanent Connection Table

    For the detail information on the parameters, please refer to M900/M1800 Base StationController Data Configuration Reference - Engineering Parameters.

    4.3.3 Configuring BTS Software Index

    This index is the one of BTS board software. Only when there is a corresponding record in[Site Software Configuration Table], can the BTS board software be loaded and activated.

    Click in Figure 4-5, the interface will pop up as shown in Figure 4-9.

    Figure 4-9BTS Software Configuration

  • 7/28/2019 01-4 Local Office Data.pdf

    12/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-8 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    Click to pop up the interface as shown in Figure 4-10.

    Figure 4-10Add Configuration Item

    Input relevant information of the to-be-configured BTS software.

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

    4.3.4 Configuring Common Parameter Table

    The default configuration is adopted to all common parameter except software parameter.

    Click in Figure 4-5, the interface will pop up as shown in Figure 4-14.

  • 7/28/2019 01-4 Local Office Data.pdf

    13/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-9

    Figure 4-11configure common parameter

    Switch to Software Parameter Table interface as shown in Figure 4-12.

  • 7/28/2019 01-4 Local Office Data.pdf

    14/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-10 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    Figure 4-12configure soft parameter

    Table 4-4 describes the meaning of the software parameters.

    Table 4-4Meaning of soft parameter

    Parameter name Default value Description

    Encryption algorithm ofdestination BSC

    Any Select the Encryption algorithm ofdestination BSC, include A5/1, A5/2, A5/3,A5/4, A5/5, A5/6, A5/7 and Any.

    Type of alarm box new alarm box Select the type of alarm box, include old ornew alarm box.

    BIE PCM alarm delay(second)

    5 Configure BIE PCM alarm delay time, theunit is second and the value rang is 0 to 15.

    Include speech versionIE in SDCCH handovermessage

    selected When checkbox is selected, speechversionIE is included in SDCCH handovermessage, otherwise, versionIE is included inSDCCH handover message.

    Always include cell IDIE in assignmentcomplete message

    not selected When checkbox is selected, cell ID IE mustbe included in assignment completemessage, otherwise, cell ID IE is included in

    assignment complete message if service cellchange when assignment channel.

  • 7/28/2019 01-4 Local Office Data.pdf

    15/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-11

    Parameter name Default value Description

    Exclude CIC pool IE in

    assignment completemessage

    not selected When checkbox is selected, Exclude CIC

    pool IE in assignment complete message,

    otherwise, keep the current rule about cicpool in assignment complete message.

    Exclude CIC pool IE in

    handover completemessage

    not selected When checkbox is selected, excluding CIC

    pool IE in handover complete message,otherwise, keep the current rule about cicpool in handover complete message.

    Support group circuit

    operation onA-interface

    selected When checkbox is selected, support group

    circuit operation on A-interface, otherwisedo not support.

    Switch to Module Description Table interface as shown Figure 4-13.

    Figure 4-13Module description table

    This table is used to configure the PCU ID which the module connects to. The element in thisdialog changes as the module number changes.

  • 7/28/2019 01-4 Local Office Data.pdf

    16/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-12 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    Table 4-5 describes the meaning of the parameters.

    Table 4-5Description of the parameters

    Parameter Default Description

    PCU ID of Module [n] 1 The ID of the PCU that the module [n] connects

    to.

    4.3.5 Configuring Flow Control

    In Figure 4-5, click , the interface will pop up as shown in Figure 4-14.

    Figure 4-14Password verification

    Input supervisor password, and click . The interface will pop up as shown in Figure

    4-15.

  • 7/28/2019 01-4 Local Office Data.pdf

    17/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-13

    Figure 4-15Set Flow Control Table

    Modify the parameters of flow control.

    4.3.6 Configuring Reserved Parameter

    It is used to configure reserved parameter in order to upgrade BSC host.

    Click in Figure 4-5. The interface will pop up as shown in Figure 4-16.

  • 7/28/2019 01-4 Local Office Data.pdf

    18/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-14 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    Figure 4-16Reserved Parameter Configuration

    Reserved parameter of each BM, site, cell, TRX can be configured in Figure 4-16.

    The button in Figure 4-5 can be clicked only after all TRXs have been assignedto cells.

    4.4 Loading Board Software

    This subsection is to configure BSC board software. If BSC board software (e.g. GMEM)need be loaded, relevant information should be configured.

    Click in Figure 4-1. The interface will pop up as shown in Figure4-17.

  • 7/28/2019 01-4 Local Office Data.pdf

    19/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-15

    Figure 4-17BSC Board Software Loading Table

    Click to pop up the interface as shown in Figure 4-18.

    Figure 4-18Add BSC Board Software Loading Information

    Input the BSC board software loading information,

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

    4.5 Configuring BSC BIE Semi-perm. Con.

    There is none concrete connection between trunk circuit and BSC BIE port in the three trunkrelay mode, which is, 6 port half rate topology, half rate ring topology and full rate ring

  • 7/28/2019 01-4 Local Office Data.pdf

    20/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-16 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    topology, so BSC BIE semi-perm. Con. must be configured in order to indicate the connectionrelationship between trunk circuit and BSC BIE port.

    Click < BSC BIE Semi-perm. Con.> in Figure 4-1, the interface will pop up as shown in

    Figure 4-19.

    Figure 4-19BSC BIE Semi-perm. Conn.

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

    4.6 Configuring Advanced Property

    4.6.1 Configuring SS7

    Click in Figure 4-1 to pop up the interface as shown in Figure 4-20.

  • 7/28/2019 01-4 Local Office Data.pdf

    21/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-17

    Figure 4-20[SS7 Signaling] tab page

    Modify the parameters of SS7.

    See Table 4-6 for the description of the parameters in [SS7 Signaling].

    Table 4-6Description of the parameters in [SS7 Signaling]

    Parameter name Default value Description

    Signaling NetworkCoding Mode

    National Standby:14bit

    Others: Not Used

    It must be configured in consistencywith the value of [Signaling NetworkIndicator] in Figure 4-2.

    SCCP Link Both None

    SP Function Identity Selected -

    STP Function Identity Deselected This parameter is to indicate whether

    OSP provides the signaling transferfunction.

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

  • 7/28/2019 01-4 Local Office Data.pdf

    22/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-18 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    4.6.2 Configuring Other Properties

    Switch the Figure 4-20 to the interface as shown in Figure 4-21.

    Figure 4-21Others properties

    Configure the other properties.

    See Table 4-7 for the description of the parameters in [Others].

    Table 4-7Description of the parameters in [Others]

    Parameter name Default value Description

    Echo Cancellation Not Supported When SS7 signaling messages are to be

    transferred via a satellite, the echocancellation function should be enabled toprovide a high-quality voice channel.

    Voice Encode/DecodeOptimization

    NormalEncode/Decode

    None

    Allowed TransmissionDelay

    10 None

    Restart Function Selected None

    Support Cell Broadcast Selected None

    High Band Support DCS1800 This parameter is used to decide whether the

    current BSC supports DCS1800 orPCS1900. It does not support dynamic

    configuration.

  • 7/28/2019 01-4 Local Office Data.pdf

    23/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-19

    Parameter name Default value Description

    LCS (Cell ID+TA)

    Allowed

    No Used to determine whether the BSC cell

    provides LCS (Cell ID+TA) or not.

    TC OWA Check Time 255 FTC OWA Check Time can be started orclosed dynamically. Check Time means:

    FTC tests the UL/DL voice service of theoccupied timeslots. If it fails to receive theUL/DL voice frame in a specified period(for example, 5 s), it reports alarm to MPU.

    GPRS Suspend TimerValue

    5 If initiates a call to a MS that is carrying out

    PS service, the PS service is suspended andthen resumed.

    The suspend flow: After send the message

    GPRS Suspend Request to PCU,,BSC starts

    the GPRS Suspend Timer Value and waitfor the PCU returns the Ack or Nackmessage. If BSC does not receive the

    response of PCU within the set timeof GPRS Suspend Timer Value, BSC setsthe status of the GPRS in CCB as no

    response received. The resume flow is notstarted.

    Inter system HO

    allowed

    Not selected Used to indicate whether the BSC supports

    inter system HO.

    For the detail information on the parameters, please refer to M900/M1800 Base Station

    Controller Data Configuration Reference - Engineering Parameters.

    4.6.3 Configuring A Interface Timeslot Occupies

    Switch the Figure 4-20 to the interface as shown in Figure 4-22.

  • 7/28/2019 01-4 Local Office Data.pdf

    24/25

    4 Local Office Data

    M900/M1800 Base Station Controller

    Initial Configuration Manual

    4-20 Huawei Technologies Proprietary Issue 07 (2006-08-20)

    Figure 4-22A Interface Timeslot Occupies

    Configure the parameters properly.

    Refer to Chapter 5 Trunk & Signaling Data of A Interface for the description of theparameters in the [A Interface Timeslot Occupies] tab page.

    4.6.4 Configuring Timer Data

    Switch the Figure 4-20 to the interface as shown in Figure 4-23.

    Figure 4-23Timer Data

  • 7/28/2019 01-4 Local Office Data.pdf

    25/25

    M900/M1800 Base Station Controller

    Initial Configuration Manual 4 Local Office Data

    Configure the parameters of timer data.

    4.7 Confirming Modification

    In Figure 4-1, click to save the modified data.