M900/M1800 Base Station Controller
Initial Configuration Manual Contents
Issue 07 (2006-08-20) Huawei Technologies Proprietary i
Contents
4 Local Office Data........................................................................................................................4-7
4.1 Overview.......................................................................................................................................................4-8
4.2 Configuring Local Office Information ........................................................................... ...............................4-8
4.1.1 Configuring Network Property............................................................................................................4-8
4.2.2 Configuring Location Property .......................................................................... ..................................4-9
4.2.3 Configuring Interface Property ................................................................. .........................................4-10
4.3 Configuring System Property......................................................................................................................4-11
4.1.1 Configuring Alarm Parameter Table ..................................................................... ............................ 4-11
4.3.2 Configuring Semi-permanent Connection ................................................................. ........................4-12
4.3.3 Configuring BTS Software Index ...................................................................... ................................4-13
4.3.4 Configuring Common Parameter Table ...................................................................... .......................4-14
4.3.5 Configuring Flow Control..................................................................................................................4-18
4.3.6 Configuring Reserved Parameter ..................................................................... ..................................4-19
4.4 Loading Board Software .......................................................... ................................................................... 4-20
4.5 Configuring BSC BIE Semi-perm. Con. .......................................................... ...........................................4-21
4.6 Configuring Advanced Property..................................................................................................................4-22
4.6.1 Configuring SS7.................................................................................................................................4-22
4.6.2 Configuring Other Properties.............................................................................................................4-24
4.6.3 Configuring A Interface Timeslot Occupies..................................... .................................................. 4-25
4.6.4 Configuring Timer Data.....................................................................................................................4-26
4.7 Confirming Modification .................................................................. .......................................................... 4-27
7/28/2019 01-4 Local Office Data.pdf
2/25
M900/M1800 Base Station Controller
Initial Configuration Manual Figures
Issue 07 (2006-08-20) Huawei Technologies Proprietary iii
Figures
Figure 4-1 [Local Office Information] tab page ...................................................................... ...........................4-8
Figure 4-2 Configure network property..............................................................................................................4-9
Figure 4-3 Configure location property............................................................................................................4-10
Figure 4-4 Configure interface property...........................................................................................................4-10
Figure 4-5 Configure system flow control property.........................................................................................4-11
Figure 4-6 Password verification......................................................................................................................4-11
Figure 4-7 Alarm Parameter Table .................................................................. ................................................. 4-12
Figure 4-8 Semi-permanent Connection Table.................................................................................................4-13
Figure 4-9 BTS Software Configuration ...................................................................... ....................................4-13
Figure 4-10 Add Configuration Item................................................................................................................4-14
Figure 4-11 configure common parameter .............................................................. .........................................4-15
Figure 4-12 configure soft parameter ........................................................... .................................................... 4-16
Figure 4-13 Module description table .............................................................. ................................................ 4-17
Figure 4-14 Password verification....................................................................................................................4-18
Figure 4-15 Set Flow Control Table ................................................................. ................................................ 4-19
Figure 4-16 Reserved Parameter Configuration...............................................................................................4-20
Figure 4-17 BSC Board Software Loading Table.............................................................................................4-21
Figure 4-18 Add BSC Board Software Loading Information...........................................................................4-21
Figure 4-19 BSC BIE Semi-perm. Conn..........................................................................................................4-22
Figure 4-20 [SS7 Signaling] tab page...............................................................................................................4-23
7/28/2019 01-4 Local Office Data.pdf
3/25
Figures
M900/M1800 Base Station Controller
Initial Configuration Manual
iv Huawei Technologies Proprietary Issue 07 (2006-08-20)
Figure 4-21 Others properties...........................................................................................................................4-24
Figure 4-22 A Interface Timeslot Occupies......................................................................................................4-26
Figure 4-23 Timer Data .................................................................. .................................................................. 4-26
7/28/2019 01-4 Local Office Data.pdf
4/25
M900/M1800 Base Station Controller
Initial Configuration Manual Tables
Issue 07 (2006-08-20) Huawei Technologies Proprietary v
Tables
Table 4-1 Description of the parameters related to network property configuration ..........................................4-9
Table 4-2 Description of the parameters related to location property configuration. .......................................4-10
Table 4-3 Description of the parameters related to interface property configuration. ...................................... 4-11
Table 4-4 Meaning of soft parameter................................................................................................................4-16
Table 4-5 Description of the parameters...........................................................................................................4-18
Table 4-6 Description of the parameters in [SS7 Signaling].............................................................................4-23
Table 4-7 Description of the parameters in [Others].........................................................................................4-24
7/28/2019 01-4 Local Office Data.pdf
5/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-1
4 Local Office Data
About This Chapter
The following table lists the contents of this chapter.
Title Description
4.1 Overview Introduces the main idea of this chapter.
4.2 Configuring Local OfficeInformation Describes the procedure for configuring the local officeinformation.
4.3 Configuring SystemProperty
Describes the procedure for configuring the systemproperty.
4.4 Loading Board Software Describes the procedure for loading the board software.
4.6 Configuring AdvancedProperty
Describes the procedure for configuring the advancedproperty.
4.7 Confirming Modification Describes the procedure for confirming modification.
7/28/2019 01-4 Local Office Data.pdf
6/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-2 Huawei Technologies Proprietary Issue 07 (2006-08-20)
4.1 Overview
BSC local office data configuration is of great significance, and has direct impact upon the
normal operation of the GMPUs in BSC.
BSC local office information describes SS7 information in BSC, e.g., OPC, DPC, SCCP, etc.
And the GSM specification supported by each interface (A/Abis/Um interface).
4.2 Configuring Local Office Information
Select the [Local Office Information] tab page in BSC Auto Data Configuration System, asshown in Figure 4-1.
Figure 4-1[Local Office Information] tab page
4.1.1 Configuring Network Property
Configure network property, as shown in Figure 4-2.
7/28/2019 01-4 Local Office Data.pdf
7/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-3
Figure 4-2Configure network property
See Table 4-1 for the description of the parameters related to network property configuration.
Table 4-1Description of the parameters related to network property configuration
Parameter name Default
value
Description
Signaling NetworkIndicator
NationalStandby
As per the actual conditions, configure thesignaling network that OSP belongs to.
BSC Signaling PointCode
None Namely, OPC. Configure this parameter as perthe network plan.
MSC Signaling PointCode
None Namely, DPC. Configure this parameter as perthe data in the peer MSC.
z All the SPCs of Huawei GSM equipment is indicated by hexadecimal. Please convert the SPCs if
there are indicated by decimal digits in relevant documents. Generally, SPC is a 14-bit signaling
code, and may be a 24-bit signaling code. To meet the various requirements of different MSCs, SPCshould be configured based on negotiation.
z When signaling abnormality occurs, user can check whether the first digit of hexadecimal in SPC is
"0", and can attempt to add "0" to or remove "0" from the first digit. "0" will change the valid bitnumber of SPC, the method to identify the number of SPC is different between different MSC.
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
4.2.2 Configuring Location Property
Configure location property, as shown in Figure 4-3.
7/28/2019 01-4 Local Office Data.pdf
8/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-4 Huawei Technologies Proprietary Issue 07 (2006-08-20)
Figure 4-3Configure location property
See Table 4-2 for the description of the parameters related to location property configuration.
Table 4-2Description of the parameters related to location property configuration.
Parameter name Defaultvalue
Description
Country Code None Namely, CC, the country code registered by MS. Forexample, the CC of China is "86".
Mobile CountryCode
None Namely, MCC, uniquely identifying the country that
MS belongs to. For example, the MCC of China is"460".
Local Area Code None Toll call area code for the area where BSC is located.
Mobile Network
Code
None Namely, MNC, identifying the PLMN that MS belongs
to.
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
4.2.3 Configuring Interface Property
Configure interface property, as shown in Figure 4-4.
Figure 4-4Configure interface property
See Table 4-3 for the description of the parameters related to interface property configuration.
7/28/2019 01-4 Local Office Data.pdf
9/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-5
Table 4-3Description of the parameters related to interface property configuration.
Parameter name Default value Description
A Interface Version GSM_Phase_2 Select an interface version as per the GSM
protocol criterion which is adopted by the Ainterface provided by MSC.
Abis InterfaceVersion
GSM_Phase_2 None
Um Interface Version GSM_Phase_2 None
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
4.3 Configuring System Property
Configure system property, as shown in Figure 4-5.
Figure 4-5Configure system flow control property
4.1.1 Configuring Alarm Parameter Table
In Figure 4-5, click , The interface will pop up as shown in Figure 4-6.
Figure 4-6Password verification
Input supervisor password, and click , the interface will pop up as shown in Figure 4-7.
7/28/2019 01-4 Local Office Data.pdf
10/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-6 Huawei Technologies Proprietary Issue 07 (2006-08-20)
Figure 4-7Alarm Parameter Table
Modify the parameters of alarm.
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
4.3.2 Configuring Semi-permanent Connection
The semi-permanent connection is to provide a transport path with the bandwidth of 64 kbit/s
for customer. It is used to transmit business hall information, BTS AC power alarminformation and other maintenance information.
Click in Figure 4-5, the interface will pop up as shown in Figure 4-8.
7/28/2019 01-4 Local Office Data.pdf
11/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-7
Figure 4-8Semi-permanent Connection Table
For the detail information on the parameters, please refer to M900/M1800 Base StationController Data Configuration Reference - Engineering Parameters.
4.3.3 Configuring BTS Software Index
This index is the one of BTS board software. Only when there is a corresponding record in[Site Software Configuration Table], can the BTS board software be loaded and activated.
Click in Figure 4-5, the interface will pop up as shown in Figure 4-9.
Figure 4-9BTS Software Configuration
7/28/2019 01-4 Local Office Data.pdf
12/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-8 Huawei Technologies Proprietary Issue 07 (2006-08-20)
Click to pop up the interface as shown in Figure 4-10.
Figure 4-10Add Configuration Item
Input relevant information of the to-be-configured BTS software.
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
4.3.4 Configuring Common Parameter Table
The default configuration is adopted to all common parameter except software parameter.
Click in Figure 4-5, the interface will pop up as shown in Figure 4-14.
7/28/2019 01-4 Local Office Data.pdf
13/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-9
Figure 4-11configure common parameter
Switch to Software Parameter Table interface as shown in Figure 4-12.
7/28/2019 01-4 Local Office Data.pdf
14/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-10 Huawei Technologies Proprietary Issue 07 (2006-08-20)
Figure 4-12configure soft parameter
Table 4-4 describes the meaning of the software parameters.
Table 4-4Meaning of soft parameter
Parameter name Default value Description
Encryption algorithm ofdestination BSC
Any Select the Encryption algorithm ofdestination BSC, include A5/1, A5/2, A5/3,A5/4, A5/5, A5/6, A5/7 and Any.
Type of alarm box new alarm box Select the type of alarm box, include old ornew alarm box.
BIE PCM alarm delay(second)
5 Configure BIE PCM alarm delay time, theunit is second and the value rang is 0 to 15.
Include speech versionIE in SDCCH handovermessage
selected When checkbox is selected, speechversionIE is included in SDCCH handovermessage, otherwise, versionIE is included inSDCCH handover message.
Always include cell IDIE in assignmentcomplete message
not selected When checkbox is selected, cell ID IE mustbe included in assignment completemessage, otherwise, cell ID IE is included in
assignment complete message if service cellchange when assignment channel.
7/28/2019 01-4 Local Office Data.pdf
15/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-11
Parameter name Default value Description
Exclude CIC pool IE in
assignment completemessage
not selected When checkbox is selected, Exclude CIC
pool IE in assignment complete message,
otherwise, keep the current rule about cicpool in assignment complete message.
Exclude CIC pool IE in
handover completemessage
not selected When checkbox is selected, excluding CIC
pool IE in handover complete message,otherwise, keep the current rule about cicpool in handover complete message.
Support group circuit
operation onA-interface
selected When checkbox is selected, support group
circuit operation on A-interface, otherwisedo not support.
Switch to Module Description Table interface as shown Figure 4-13.
Figure 4-13Module description table
This table is used to configure the PCU ID which the module connects to. The element in thisdialog changes as the module number changes.
7/28/2019 01-4 Local Office Data.pdf
16/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-12 Huawei Technologies Proprietary Issue 07 (2006-08-20)
Table 4-5 describes the meaning of the parameters.
Table 4-5Description of the parameters
Parameter Default Description
PCU ID of Module [n] 1 The ID of the PCU that the module [n] connects
to.
4.3.5 Configuring Flow Control
In Figure 4-5, click , the interface will pop up as shown in Figure 4-14.
Figure 4-14Password verification
Input supervisor password, and click . The interface will pop up as shown in Figure
4-15.
7/28/2019 01-4 Local Office Data.pdf
17/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-13
Figure 4-15Set Flow Control Table
Modify the parameters of flow control.
4.3.6 Configuring Reserved Parameter
It is used to configure reserved parameter in order to upgrade BSC host.
Click in Figure 4-5. The interface will pop up as shown in Figure 4-16.
7/28/2019 01-4 Local Office Data.pdf
18/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-14 Huawei Technologies Proprietary Issue 07 (2006-08-20)
Figure 4-16Reserved Parameter Configuration
Reserved parameter of each BM, site, cell, TRX can be configured in Figure 4-16.
The button in Figure 4-5 can be clicked only after all TRXs have been assignedto cells.
4.4 Loading Board Software
This subsection is to configure BSC board software. If BSC board software (e.g. GMEM)need be loaded, relevant information should be configured.
Click in Figure 4-1. The interface will pop up as shown in Figure4-17.
7/28/2019 01-4 Local Office Data.pdf
19/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-15
Figure 4-17BSC Board Software Loading Table
Click to pop up the interface as shown in Figure 4-18.
Figure 4-18Add BSC Board Software Loading Information
Input the BSC board software loading information,
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
4.5 Configuring BSC BIE Semi-perm. Con.
There is none concrete connection between trunk circuit and BSC BIE port in the three trunkrelay mode, which is, 6 port half rate topology, half rate ring topology and full rate ring
7/28/2019 01-4 Local Office Data.pdf
20/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-16 Huawei Technologies Proprietary Issue 07 (2006-08-20)
topology, so BSC BIE semi-perm. Con. must be configured in order to indicate the connectionrelationship between trunk circuit and BSC BIE port.
Click < BSC BIE Semi-perm. Con.> in Figure 4-1, the interface will pop up as shown in
Figure 4-19.
Figure 4-19BSC BIE Semi-perm. Conn.
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
4.6 Configuring Advanced Property
4.6.1 Configuring SS7
Click in Figure 4-1 to pop up the interface as shown in Figure 4-20.
7/28/2019 01-4 Local Office Data.pdf
21/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-17
Figure 4-20[SS7 Signaling] tab page
Modify the parameters of SS7.
See Table 4-6 for the description of the parameters in [SS7 Signaling].
Table 4-6Description of the parameters in [SS7 Signaling]
Parameter name Default value Description
Signaling NetworkCoding Mode
National Standby:14bit
Others: Not Used
It must be configured in consistencywith the value of [Signaling NetworkIndicator] in Figure 4-2.
SCCP Link Both None
SP Function Identity Selected -
STP Function Identity Deselected This parameter is to indicate whether
OSP provides the signaling transferfunction.
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
7/28/2019 01-4 Local Office Data.pdf
22/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-18 Huawei Technologies Proprietary Issue 07 (2006-08-20)
4.6.2 Configuring Other Properties
Switch the Figure 4-20 to the interface as shown in Figure 4-21.
Figure 4-21Others properties
Configure the other properties.
See Table 4-7 for the description of the parameters in [Others].
Table 4-7Description of the parameters in [Others]
Parameter name Default value Description
Echo Cancellation Not Supported When SS7 signaling messages are to be
transferred via a satellite, the echocancellation function should be enabled toprovide a high-quality voice channel.
Voice Encode/DecodeOptimization
NormalEncode/Decode
None
Allowed TransmissionDelay
10 None
Restart Function Selected None
Support Cell Broadcast Selected None
High Band Support DCS1800 This parameter is used to decide whether the
current BSC supports DCS1800 orPCS1900. It does not support dynamic
configuration.
7/28/2019 01-4 Local Office Data.pdf
23/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Issue 07 (2006-08-20) Huawei Technologies Proprietary 4-19
Parameter name Default value Description
LCS (Cell ID+TA)
Allowed
No Used to determine whether the BSC cell
provides LCS (Cell ID+TA) or not.
TC OWA Check Time 255 FTC OWA Check Time can be started orclosed dynamically. Check Time means:
FTC tests the UL/DL voice service of theoccupied timeslots. If it fails to receive theUL/DL voice frame in a specified period(for example, 5 s), it reports alarm to MPU.
GPRS Suspend TimerValue
5 If initiates a call to a MS that is carrying out
PS service, the PS service is suspended andthen resumed.
The suspend flow: After send the message
GPRS Suspend Request to PCU,,BSC starts
the GPRS Suspend Timer Value and waitfor the PCU returns the Ack or Nackmessage. If BSC does not receive the
response of PCU within the set timeof GPRS Suspend Timer Value, BSC setsthe status of the GPRS in CCB as no
response received. The resume flow is notstarted.
Inter system HO
allowed
Not selected Used to indicate whether the BSC supports
inter system HO.
For the detail information on the parameters, please refer to M900/M1800 Base Station
Controller Data Configuration Reference - Engineering Parameters.
4.6.3 Configuring A Interface Timeslot Occupies
Switch the Figure 4-20 to the interface as shown in Figure 4-22.
7/28/2019 01-4 Local Office Data.pdf
24/25
4 Local Office Data
M900/M1800 Base Station Controller
Initial Configuration Manual
4-20 Huawei Technologies Proprietary Issue 07 (2006-08-20)
Figure 4-22A Interface Timeslot Occupies
Configure the parameters properly.
Refer to Chapter 5 Trunk & Signaling Data of A Interface for the description of theparameters in the [A Interface Timeslot Occupies] tab page.
4.6.4 Configuring Timer Data
Switch the Figure 4-20 to the interface as shown in Figure 4-23.
Figure 4-23Timer Data
7/28/2019 01-4 Local Office Data.pdf
25/25
M900/M1800 Base Station Controller
Initial Configuration Manual 4 Local Office Data
Configure the parameters of timer data.
4.7 Confirming Modification
In Figure 4-1, click to save the modified data.