Project :- Wago Canada
Location :- 1550 Yorkton Rd, Burlington, ON
Estimate Date :- 20th of September 2019
Estimator :- Tesbee Consultancy
Description Unit Qunatity Unit Rate Amount
ElectricalLighting
1 Total Lighting Fixtures - fixing only Nos 22 110.00 2,420.00
2 Allow for wiring and conduit for Lighting Nos 22 115.00 2,530.00
Power3 Duplex Receptacle Nos 42 160.00 6,720.00
4 GFI Duplex Receptacle Nos 5 165.00 825.00
5 Allow for wiring and conduit Nos 47 140.00 6,580.00
6 120V Power Connection to Exhaust Fan and Dishwasher Nos 3 250.00 750.00
7 Power Requirement to Washroom Equipments Nos 8 250.00 2,000.00
Data And Communication
8 Data Outlet Nos 29 175.00 5,075.00
9 Telephone Outlet Nos 10 175.00 1,750.00
10 Allow for cable and conduit Nos 39 185.00 7,215.00
Fire Alarm11 Fire Alarm System Horn Nos 3 220.00 660.00
Controllers12 Occupancy Sensor Nos 1 275.00 275.00
13 Allowfor main wiring Sum 1 1,000.00 1,000.00
14 Allow for control panel Modification Sum 1 1,200.00 1,200.00
15 Allow for repire Existing works damage occur from new work Sum 1 1,000.00 1,000.00
Total 40,000.00
Insurance 3% 1,200.00
Overhead and Profit 22% 8,800.00
Total Amount 50,000.00
Note:
Electrical Estimate
[email protected] www.tesbee.ca +1 416 856 6000 / +1 888 538 9374
1
11 - Light - 15 EA
WAGO_Canada_-_MEP_(002)_FINAL.pdf (14) (45% of Scale); Takeoff in Active Area: All Areas; Electrical 372; OST Sample Projects v2; 20-Sep-19 12:09 AM
[email protected] www.tesbee.ca +1 416 856 6000 / +1 888 538 9374
2
11 - Light - 6 EA
WAGO_Canada_-_MEP_(002)_FINAL.pdf (15) (45% of Scale); Takeoff in Active Area: All Areas; Electrical 372; OST Sample Projects v2; 20-Sep-19 12:09 AM
[email protected] www.tesbee.ca +1 416 856 6000 / +1 888 538 9374
3
1 - Duplex Receptacle - 16 EA
2 - GFI Duplex Receptacle - 3 EA
3 - Data Outlet - 5 EA
5 - Telephone Outlet - 2 EA
6 - 120V Power Connection to Exhaust Fan and Dishwasher - 2 EA
7 - Fire Alarm System Horn - 2 EA
8 - Fire Alarm System Horn (Existing Fixture) - 3 EA
9 - Fire Alarm System Pull Station (Existing Fixture) - 4 EA
10 - Power Requirement to Washroom Equipments - 8 EA
WAGO_Canada_-_MEP_(002)_FINAL.pdf (16) (45% of Scale); Takeoff in Active Area: All Areas; Electrical 372; OST Sample Projects v2; 20-Sep-19 12:09 AM
[email protected] www.tesbee.ca +1 416 856 6000 / +1 888 538 9374
4
2 - GFI Duplex Receptacle - 2 EA1 - Duplex Receptacle - 26 EA
7 - Fire Alarm System Horn - 1 EA6 - 120V Power Connection to Exhaust Fan and Dishwasher - 1 EA
3 - Data Outlet - 24 EA5 - Telephone Outlet - 8 EA
8 - Fire Alarm System Horn (Existing Fixture) - 1 EA
WAGO_Canada_-_MEP_(002)_FINAL.pdf (17) (45% of Scale); Takeoff in Active Area: All Areas; Electrical 372; OST Sample Projects v2; 20-Sep-19 12:09 AM
[email protected] www.tesbee.ca +1 416 856 6000 / +1 888 538 9374
5