2
50A55-843 Universal Cross Reference Chart See other side for 50A50 replacement Cross Reference Type Number 50A55-120 50A55-143 50A55-285 50A55-286 50A55-288 50A55-438 50A55-474, -571 50A55-843 Pre-Purge 15 30 0 0 0 0 0 30 Trial for Ignition 4 4 4 7 4 4 4 4 Ignition Activation Period 1 4 4 4 1 3 1 1 Retries 4 times 4 times 2 times 2 times 2 times 2 times 2 times 2 times Valve Sequence Period 12 20 12 21 12 12 12 12 Interpurge 15 60 60 15 60 60 60 60 Post-Purge 5 5 15 15 15 5 5 15 Lockout Time 150 678 272 272 300 269 300 300 Heat Delay-to-Fan-On 45 15, 30, 45, 60 30 30 30 45 45 30, 45 Heat Delay-to-Fan-Off 60, 90, 120, 180 60, 90, 120, 180 60, 90, 120, 180 60, 90, 120, 180 60, 90, 120, 180 60, 90, 120, 180 60, 100, 140, 180 60, 90, 120, 180 Cool Delay-to-Fan-On 0 0 0 0 5 2 2 5 Cool Delay-to-Fan-Off 0 45 45 45 45 0, 80 0,,80 45, 90 Air Cleaner terminal Yes Yes Yes Yes Yes Yes Yes Yes Humidifier terminal Yes Yes Yes Yes Yes Yes Yes Yes Replaces * All times are in seconds *The Universal 50A55-843 control will replace all 50A50 and 50A55 models 1 Part No. 37-6376A 0204

0037-6376

Embed Size (px)

DESCRIPTION

American Standard control board settings

Citation preview

Page 1: 0037-6376

50A55-843 Universal Cross Reference Chart

See other side for 50A50 replacement Cross Reference

Type Number 50A55-120 50A55-143 50A55-285 50A55-286 50A55-288 50A55-43850A55-474,

-57150A55-843

Pre-Purge 15 30 0 0 0 0 0 30Trial for Ignition 4 4 4 7 4 4 4 4

Ignition ActivationPeriod 1 4 4 4 1 3 1 1Retries 4 times 4 times 2 times 2 times 2 times 2 times 2 times 2 times

Valve SequencePeriod 12 20 12 21 12 12 12 12

Interpurge 15 60 60 15 60 60 60 60Post-Purge 5 5 15 15 15 5 5 15

Lockout Time 150 678 272 272 300 269 300 300Heat

Delay-to-Fan-On 4515, 30,45, 60

30 30 30 45 45 30, 45

HeatDelay-to-Fan-Off

60, 90,120, 180

60, 90,120, 180

60, 90,120, 180

60, 90,120, 180

60, 90,120, 180

60, 90,120, 180

60, 100,140, 180

60, 90,120, 180

CoolDelay-to-Fan-On 0 0 0 0 5 2 2 5

CoolDelay-to-Fan-Off 0 45 45 45 45 0, 80 0,,80 45, 90

Air Cleanerterminal Yes Yes Yes Yes Yes Yes Yes Yes

Humidifierterminal Yes Yes Yes Yes Yes Yes Yes Yes

Replaces *

All times are in seconds

*The Universal 50A55-843 control will replace all 50A50 and 50A55 models

1

Part No. 37-6376A

0204

Page 2: 0037-6376

50A55-843 Universal Cross Reference Chart

Type NumberPre-Purge

Trial for IgnitionIgnition Activation

PeriodRetries

Valve SequencePeriod

InterpurgePost-Purge

Lockout TimeHeat

Delay-to-Fan-OnHeat

Delay-to-Fan-OffCool

Delay-to-Fan-OnCool

Delay-to-Fan-OffAir Cleaner

terminalHumidifierterminal

Replaces

See other side for 50A55 replacement Cross Reference

50A50-143 50A50-285 50A50-286 50A50-438 50A55-843

30 0 0 0 307 7 7 6 4

4 4 4 3 16 times 2 times 2 times 2 times 2 times

49 21 21 18 1260 60 60 60 600 15 15 5 15

678 272 272 269 300

15, 30, 45, 60 30 30 45 30, 45

60, 90,120, 180

9060, 90,

120, 18090, 120,150, 210

60, 90,120, 180

0 5 0 2 5

110 45 45 0, 80 45, 90

Yes Yes N/A Yes Yes

Yes Yes N/A Yes Yes50A50-110,-111, -112,

-113

50A50-205,-206, -207,-288, -295

50A50-209,-296

50A50-405,-406,-408,-471, -472,-473, -474

*

All times are in seconds

*The Universal 50A55-843 control will replace all 50A50 and 50A55 models

2

Part No. 37-6376A

0204