82
Refrigerant gas R410A Aluminum micro-channel heat exchangers Shell and tubes exchanger Electronic expansion valve supplied standard ‘CLASS A’ efciency Integrated hydronic module Chiller, air source for outdoor installation NECS_1314_3218_201211 _EN (The photo of the unit is indicative and may change depending on the model) Climaveneta Technical Bulletin 1314 - 3218 354 - 885 kW NECS

00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

  • Upload
    others

  • View
    3

  • Download
    0

Embed Size (px)

Citation preview

Page 1: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

Refrigerant gas R410A Aluminum micro-channel heat exchangers Shell and tubes exchanger Electronic expansion valve supplied standard ‘CLASS A’ effi ciency Integrated hydronic module

Chiller, air source for outdoor installation

NECS_1314_3218_201211_EN

(The photo of the unit is indicative and may change depending on the model)

Climaveneta Technical Bulletin

1314 - 3218354 - 885 kW

NECS

Page 2: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

This company participates in the Eurovent Certifi cation Programme. The products are listed

in the Directory of certifi ed products. The Eurovent certifi cate, for the applicable units,

refers to products with cooling capacity up to 600 kW, voluntarily extended up to 1500 kW, for

air-cooled models and water-cooled models.

Climaveneta S.p.A.:

Quality System complying with the requirements of UNI EN ISO9001:2008 regulation

Environmental Management System complying with the requirements of UNI EN ISO14001:2004 regulation

CERTIFICATIONS

Product certifi cations

Voluntary product certifi cations

System certifi cations

Page 3: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

II

NECS

HFC R410A

SUMMARYNECS

1314 - 3218

Liability disclaimerThis bulletin is not exhaustive about: installation, use, safety precautions, handling and transport. Refer to “General Manual for Installation” for further informations.This bulletin refers to standard executions, in particular for di-mension, weight, electric, hydraulic, aeraulic and refrigerant connections (whereas applicable). Contact Climaveneta Com-mercial Offi ce for further drawings and schemes.

Climaveneta declines any liability derived from the bulletin’s use. This bulletin is of exclusive property of Climaveneta, and all forms of copy are prohibited. The information contained in this document may be modifi ed without prior notice.

1. Product presentation 1.1 Refrigerant gas R410A 1.2 Aluminum micro-channel heat exchangers 1.3 Shell and tubes exchanger 1.4 Electronic expansion valve supplied standard 1.5 ‘CLASS A’ effi ciency 1.6 Integrated hydronic module

2. Unit description 2.1 Standard unit layout 2.2 Certifi cation, reference standards 2.3 Tests 2.4 Controller 2.5 Functions 2.6 Versions 2.7 Accessories

3. Electronic controller 3.1 Control unit with LED display

4. Technical data 4.1 General technical data 4.2 Cooling capacity performance 4.3 Desuperheater capacity performance 4.4 Recovery capacity performance

5. Selection limits 6. Hydraulic data

6.1 Water fl ow and pressure drop 7. Hydronic groups (Optional) 8. Electrical data 9. Full load sound level 10. Dimensional drawings 11. Key to hydraulic connections

pg. n° III pg. n° III pg. n° III pg. n° III pg. n° III pg. n° III pg. n° III pg. n° 1 pg. n° 1 pg. n° 1 pg. n° 1 pg. n° 2pg. n° 2 pg. n° 2 pg. n° 3 pg. n° 4 pg. n° 4 pg. n° 6 pg. n° 6 pg. n° 14 pg. n° 25 pg. n° 36 pg. n° 47 pg. n° 50 pg. n° 50 pg. n° 54 pg. n° 65 pg. n° 69 pg. n° 73 pg. n° 78

The units highlighted in this publication contain HFC R410A [GWP100 2088] fluorinated greenhouse gases.

Page 4: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

III

NECS

HFC R410A

This section contains general information on the NECS-N ran-ge of products. For detailed information refer to the specifi c sections in this bulletin.

NECS units

Outdoor unit for the production of chilled water with hermetic rotary Scroll compressors, ozone-friendly refrigerant R410A, axial-fl ow fans, shell and tubes exchanger, micro-channel full-aluminum air coils and electronic expansion valve. The range is composed by units equipped from four to eight compressors in multi-circuit confi guration.

1.1 Refrigerant gas R410A

The use of R410A has resulted in units offering better energy effi ciency in full respect for the environment (ODP = 0).

1.2 Aluminum micro-channel heat exchangers

The new NECS uses aluminum micro-channel condensers that ensure a premium level of effi ciency. This solution also allows to reduce the refrigerant charge with respect to traditional cop-per/aluminum coils as well as improving the resistance against corrosion in saline or corrosive atmospheres.

1.3 Shell and tubes exchanger

The shell and tube exchanger allows to achieve the highest fl exibility on the unit’s installation, keeping the effi ciency at the maximum level. For this reason, NECS represents the best choice for all the hydronic application on the residential, com-mercial and industrial markets.

1.4 Electronic expansion valve supplied standard

The use of the electronic expansion valve generates considera-ble benefi ts, especially in cases of variable demand and diffe-rent external conditions. It was introduced into these units as a result of accurate design choices concerning the cooling circuit and the optimisation of operation in various different working conditions.

1.5 ‘CLASS A’ effi ciency

The full range is also available with the Class A effi ciency ra-ting. NECS/CA e NECS/SL-CA guaranties premium levels of effi ciency thanks to the generous sizing of the refrigerant-ex-change surface areas and to an accurate control of the fans.

1.6 Integrated hydronic module

The incorporated hydronic unit already contains the main water circuit components; it is available in various confi gurations with one or two pumps with high or low head and the buffer tank.

1. PRODUCT PRESENTATION

Page 5: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

1

NECS

HFC R410A

CHILLER, AIR SOURCE FOR OUTDOOR INSTALLATION Outdoor unit for the production of chilled water with hermetic rotary Scroll compressors, ozone-friendly refrigerant R410A, axial-fl ow fans, shell and tubes exchanger, micro-channel full-aluminum air coils and electronic expansion valve. The range is composed by units equipped from four to eight compressors in multi-circuit confi guration.

2.1 Standard unit layout

Structure Structure specifi cally designed for outdoor installation. Base-ment and frame in hot-galvanised shaped sheet steel with a suitable thickness. All parts polyester-powder painted to assure total weather resistance.

Refrigerant circuit Main components of the cooling circuit: - two to four circuits with tandem compressors for each circuit, - R410A refrigerant, - multi-circuit shell and tubes heat exchangers, - anti-freeze heaters on both heat exchangers, - liquid line check valve, - dehydrator fi lter, - coolant line sight glass with humidity indicator, - electronic thermostatic valves, - high and low pressure transducers, - high and low pressure gauges, - high pressure safety valve, - low pressure safety valve, - high pressure safety switches, - crankcase heater on each compressor.

Compressor Rotary hermetic scroll compressors in tandem layout complete with oil sump heater, electronic overheating protection with cen-tralised manual reset and a two-pole electric motor.

User (side) heat exchanger water Direct expansion multi-circuit shell and tube exchanger with asymmetric side coolant fl ows for maintaining the coolant at the correct speed inside the tubes when passing from the liquid to the gas phase. Steel shell with foamed closed-cell elasto-mer anti-condensation lining. The shell & tube is manufactured using copper tubes with internal grooves for favouring heat ex-change and mechanically expanded onto the tube plates. An electric antifreeze heater prevents the ice from forming inside the exchanger when the unit is not working but connected to the electrical supply. When the unit is working, it is protected by a differential pressure switch mounted on the water side. Heat ex-changer featuring two, three or four coolant circuits depending on the model. The hydronic group is composed by: - differential pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure

Source (side) heat exchanger air Full-aluminum coil made by aluminum tubes and fi ns. The alu-minum fi ns are correctly spaced to guarantee optimum heat exchange effi ciency. The differentiated circulation suitably di-stributes the liquid in the coil during the expansion phase. Coil structure made with an open-angle V-geometry layout.

Electrical panel Electric power and control panel, built to EN 60204-1/EC 204-1 standards, complete with: - control circuit transformer, - general door lock isolator, - fuses and contactors for compressors and fans, - auxiliary 4..20mA analogue input - terminals for cumulative alarm block (BCA), - remote ON/OFF terminals, - relays for remote pump(s) activation for both circuits (only for

units without hydronic pumps), - spring-type control circuit terminal board, - electric panel with double door and seals for outdoor instal-

lation, - electrical board for outdoor installation, - electronic controller, - multi-language user keypad with LCD display, - IP54 protection, - Power input: 400V~ ±10% - 50Hz - 3N.

Fan section Ventilation system composed by 800mm axial electric fans, protected to IP54, with external rotor and plastic-coated alumi-num blades. Housed in aerodynamic hoods complete with safety grille. 6 - pole electric motor with built-in overload protection. Continuous adjustment of fan rotation speed.

Certifi cation, reference standard The unit complies with the following directives and relative amendments: - Machinery Directive: 2006/42/EC. - E.C.D. 89/336/EEC + 2004/108/EC. - Low Voltage Directive 2006/95/EC. - Pressure Equipment Directive 97/23/EC. Mod. A1. - TÜV-Italy

0948

Tests Tests performed throughout the production process, as indica-ted in ISO9001. Performance or noise tests can be performed by highly qualifi ed staff in the presence of customers. Performance tests comprise the measurement of: - electrical data - water fl ow rates - working temperatures - power input - power output - pressure drops on the water-side exchanger both at full load

(at the conditions of selection and at the most critical condi-tions for the condenser) and at part load conditions.

During performance testing it is also possible to simulate the main alarm states. Noise tests are performed to check noise emissions according-to ISO3744.

2. UNIT DESCRIPTION

Page 6: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

2

NECS

HFC R410A

2.4 Controller

The W3000SE Compact controller offers advanced functions and algorithms. The keypad features an easy-to-use interface and a complete LCD display, allowing to consult and intervene on the unit by means of a multi-level menu, with selectable language setting. The regulation is based on the exclusive QuickMind algorithm, including self-adaptive control logics, benefi cial in low water content systems. As alternatives the proportional- or proportional-integral regula-tions are also available. The diagnostics includes a complete alarm management, with the “black-box” and alarm logging functions for enhanced analy-sis of the unit operation. For multiple units’ systems, the regulation of the resources, via optional proprietary devices, can be implemented. Energy metering, for both consumption and capacity, can also be developed. Supervision can be easily developed via proprietary devices or the integration in third party systems by means of the most common protocols as ModBus, Bacnet, Bacnet-over-IP, Eche-lon LonWorks. Compatibility with the remote keyboard managing up to 10 units.Availability of an internal real time clock for operation schedu-ling (4-day profi les with 10 hour belts). The defrost adopts a proprietary self-adaptive logic, which fea-tures the monitoring of numerous operational parameters. This allows to reduce the number and duration of the defrost cycles, with a benefi t for the overall energy effi ciency.

2.5 Functions

Basic model

Unit without heat recovery.

Model with partial heat recovery (D)

Air cooled chiller with partial heat recovery. Compared with the basic confi guration, this version features an additional refriger-ant/water heat exchanger on the gas delivery line. This heat exchanger, fi tted in series before the traditional cooling circuit condenser, is large enough to recover heat for the production of medium-to-high temperature water for domestic hot water and the like. The heating capacity of the heat recovery circuit is ap-proximately equal to the power input of the compressor.

Model with total heat recovery (R)

Air cooled chiller with total heat recovery. Compared with the basic confi guration, this version features an additional refriger-ant/water heat exchanger on the gas delivery line. This heat exchanger, fi tted in parallel with the traditional cooling circuit condenser, is large enough to recover heat for the production of domestic hot water and the like. The heating capacity of the heat recovery circuit is approximately equal to the cooling pow-er plus the power input of the compressors. Units with total heat reclaim use conventional cupper tubes with aluminum fi ns coils as standard. All-aluminum micro-channel heat exhangers are not avaliable on these units.

2.6 Versions

B - Base

Base version.

SL - Super low noise

Super low noise version. This confi guration features special soundproofi ng for the compressor chamber and pumps (if pre-sent), reduced fan speed and an oversized condensing section. Fan speed is automatically increased, however, in the event of particularly tough environmental conditions.

CA - Class A

Class A high-effi ciency version according to Eurovent criteria. This confi guration features an oversized condensing section.

SL-CA - Super low noise class A

Super Low-noise version, Class A of effi ciency as per Eurovent. Acoustic insulation on the compressors box, on pipes and a low fans´ rotational speed gives the minimization of sound emis-sion.Acoustic insulation on the compressors box, on pipes and a low fans´ rotational speed gives the minimization of sound emis-sion.

UNIT DESCRIPTION

Page 7: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

3

NECS

HFC R410A

2.7 Accessories

Cu/Cu condensing coils-Air-refrigerant heat exchanger with copper fi ns and tubes.Recommended for applications in corrosive atmospheres.

Condensing coils with epoxy-coated fi ns-Painted air-refrigerant heat exchanger, avaliable on conven-tional cupper tubes with aluminum fi ns only. All-aluminum micro-channel heat exhangers are not avaliable with this option.Recommended for applications in medium level pollution atmospheres.

Condensing coils with Fin Guard Silver treatment-Air-refrigerant heat exchanger with epoxidic treatment on coils and fi ns, available on conventional cupper tubes with aluminum fi ns only. All-aluminum micro-channel heat exhan-gers are not avaliable with this option. Recommended for marine exposure conditions, with an high level of pollution or other aggressive atmospheres.

Soft start-Electronic device adopted to manage the inrush current.Break down of the inrush current as soon as the electrical motor is switch on, lower motor’s mechanical wear, favoura-ble sizing for the electrical system.

Remote phase-sequence control-Relay for controlling the phase-sequence of mains.Protects loads against faults due to incorrect connection of the electric line.

Compressors’ on/off signal-Auxiliary contacts providing a voltage-free signal.Allows remote signalling of compressor’s activation or remo-te control of any auxiliary loads.

ModBUS connectivity-Interface module for ModBUS protocols.Allows integration with BMS operating with ModBUS proto-col.

BACnet connectivity-Interface module for BACnet protocols.Allows integration with BMS operating with BACnet protocol.

Echelon connectivity-Interface module for Echelon systems.Allows integration with BMS operating with Echelon proto-col.

HP and LP gauges-High and low pressure gauges.Allows immediate reading of the pressure values on both low and high pressure circuits.

Compressor suction valve-Shut-off solenoid valve on compressor’s suction circuit.Simplifi es maintenance activities.

Compr. discharge line valve-Shut-off solenoid valve on compressor discharge circuit.Simplifi es maintenance activities.

Automatic circuit breakers-Over-current switch on the major electrical loads.It protects compressors and/or fans from possible current peaks.

Input remote demand limit-Digital input (voltage free).It permits to limit the unit’s power absorption for safety rea-sons or in temporary situation.

Anti-intrusion grille-Anti-intrusion grille.Avoid the intrusion of solid bodies into the unit’s structure.

Numbered cables on electrical board-

Remote signal double sp-Allows to activate the Energy Saving set-point.Enforce Energy Saving policy.

Spring anti vibration device-

Tank antifreeze heater-Anti-frost electrical heater.Prevents frost formation in the buffer tank.

BACnet OVER IP connectivity-Interface module for BACnet OVER-IP protocols.Allows to interconnect BACnet devices over Internet Proto-col within wide-area networks.

Enclosure & ext.conn.-Acoustic encolsure on both compressor and pump sections (when applicable), water connections fl ush with chiller enclo-sure. Standard on SL and SL-CA versions. Noise emission reduction.

Side panels on the coils-Metallic panels on the coils (piping side only). Standard on SL and SL-CA versions. Improve protection and unit’s aesthetics.

Reinforcing bars-Bars used to reinforce the structure.Improve resistance during long transportation.

Extra inslutation for low temperature-Increased insulation in 20 mm thick closed-cell expanded polyurethane.Prevents problems related to condensate. Recommended with leaving water temperature lower than -8°C.

UNIT DESCRIPTION

Page 8: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

4

NECS

HFC R410A

3.1 CONTROL UNIT with LED display

The W3000Compact control unit with liquid crystal display (LCD) is fi tted on all the units. This keypad uses a user interfa-ce with a choice of seven European languages: Italian, English, French, German, Spanish, Swedish and Russian. This allows the control unit interface to be chosen to suit the country of de-stination or, thanks to English, to be completely independent for all geographical areas.

This type of operator panel is also available as a remote keypad, to be connected to the unit by means of a serial connection up to a maximum distance of 200 metres without a power supply (in this case, power is supplied by the unit), or a maximum of 500 metres with a dedicated local power supply.

It is possible to interface with commercially available BMS sy-stems as it is compatible with the BACnet, BAC- net OverIP, ModBUS and LonWorks protocols.

The Black Box stores 200 alarm events; these can be printed with any kind of personal computer.

The Internal Clock manages a weekly scheduler organised into time bands in order to optimise unit performance by mini-mising power consumption. Up to 10 daily time bands can be associated with different operating setpoints. As a result, power production is optimised during daily peaks of demand and mi-nimised during periods of inactivity, such as during the night. If there is no demand for hot or chilled water, the clock can switch the unit off and switch it back on later.

Heat adjustment is performed using algorithms based on proportional step control or on proportional/integral on the two probes at the inlet and outlet of the heat exchanger. There is also the QuickMind algorithm which was especially developed by Climaveneta to ensure the unit operates correctly even with systems featuring a low water content.

QuickMind is a special control unit which monitors the main operating parameters, predicts system behaviour and anticipa-tes unit settings in order to constantly optimise performance; it allows both return and delivery water temperatures to be cho-sen as adjustment parameters. It can reduce outlet temperatu-re fl uctuations even with a small amount of water in the system. When, for dual-compressor chillers featuring a maximum of 12 start-ups per hour and using a traditional adjustment system, the minimum recommended water content is 5.5 l/kW, Quick-Mind ensures the same chiller operates correctly even with a water content of just 2.5 l/kW and considerably reduces outlet temperature fl uctuations. The above graph shows that outlet temperature fl uctuations with QuickMind are limited to 4.3°C as opposed to 7.54°C if the traditional adjustment system were used, without even ensuring an acceptable minimum compres-sor start time.

3. ELECTRONIC CONTROLLER

Page 9: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

5

NECS

HFC R410A

ELECTRONIC CONTROLLER

2

3

5

4

65.9

4.56

7.54

11.34

3 3

3.93.3 3.2 3.1

7

8

10

9

Out

put

tem

per

atur

e (°

C)

Variation output temperature

11

12

0.5 1.5 2.5 3.5 4.5 5.5 6.5 7.5 8.5 9.5

4.3

3.53

Minimum water content in the plant lt/kW

11.510.5

3.52 3.52 3.52 3.52 3.523,68 3.52

Not acceptable minimum starting time compressors

Step-wise regulation

Quickmind

Page 10: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

6

NECS / B4.1 GENERAL TECHNICAL DATA

NECS / B 1314 1414 1614 1715 1816 2015 2116 2316 2416 2418Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50PERFORMANCECOOLING ONLY (GROSS VALUE)Cooling capacity (1) kW 354 379 413 458 501 526 569 604 635 665Total power input (1) kW 124 130 148 160 172 184 195 214 219 234EER (1) 2,85 2,91 2,80 2,86 2,92 2,86 2,91 2,82 2,90 2,85ESEER (1) 4,16 4,24 4,04 4,19 4,21 4,07 4,18 4,11 4,08 4,12COOLING ONLY (EN14511 VALUE)Cooling capacity (1)(2) kW 353 377 412 456 499 524 567 602 632 663EER (1)(2) 2,80 2,87 2,75 2,81 2,87 2,82 2,87 2,78 2,86 2,81ESEER (1)(2) 3,95 4,06 3,86 3,99 3,99 3,91 4,00 3,94 3,90 3,94Cooling energy class C C C C C C C C C CCOOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 368 393 429 475 520 545 591 626 659 690Total power input (3) kW 121 126 143 155 166 178 189 207 212 226Desuperheater heating capacity (3) kW 100 105 121 131 139 150 158 175 177 187COOLING WITH TOTAL HEAT RECOVERYCooling capacity with total heat recovery (4) kW 365 390 436 473 514 545 585 628 655 686Total power input (4) kW 107 113 126 139 150 158 170 184 189 200Recovery heat exchanger capacity (4) kW 466 496 554 604 655 694 744 801 832 874EXCHANGERSHEAT EXCHANGER USER SIDE IN REFRIGERATIONWater flow (1) m³/h 61,0 65,2 71,2 78,9 86,3 90,5 98,0 104 109 115Pressure drop (1) kPa 54,0 43,8 52,2 48,5 58,1 39,3 46,1 44,3 49,0 48,5PARTIAL RECOVERY USER SIDE INREFRIGERATIONWater flow (3) m³/h 17,4 18,3 21,1 22,7 24,2 26,0 27,5 30,4 30,8 32,5Pressure drop (3) kPa 35,6 33,9 44,8 40,7 42,7 42,0 43,1 52,8 54,1 46,5HEAT EXCHANGER RECOVERY USER SIDE INREFRIGERATIONWater flow (4) m³/h 80,9 86,2 96,3 105 114 121 129 139 145 152Pressure drop (4) kPa 94,9 76,4 95,6 69,4 81,6 69,7 80,3 79,5 85,7 85,3COMPRESSORSN. of compressors N° 4 4 4 5 6 5 6 6 6 8Number of capacity N° 4 4 4 5 6 5 6 6 6 8No. of circuits N° 2 2 2 2 2 2 2 3 2 4Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPSMin. capacity step % 25 25 25 20 17 20 17 17 17 12.5Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410ARefrigerant charge kg 39,0 45,0 45,0 53,0 58,0 63,0 67,0 67,0 76,0 75,0Oil charge kg 25,0 25,0 25,0 32,0 38,0 32,0 38,0 38,0 38,0 50,0FANSQuantity N° 3 3 3 4 4 3 4 3 5 3Air flow m³/s 35,7 34,1 34,1 39,8 45,5 45,5 51,1 51,1 56,8 69,9Fans power kW 2,00 2,00 2,00 2,00 2,00 2,00 2,00 2,00 2,00 2,00NOISE LEVELNoise Pressure (5) dB(A) 64 64 64 64 65 65 64 64 65 65Noise Power (6) dB(A) 96 96 96 96 97 97 97 97 98 98SIZE AND WEIGHTA (7) mm 3905 3905 3905 5080 5080 5080 6255 6255 6255 7430B (7) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (7) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (7) kg 2730 2770 2800 3400 3650 3690 4200 4220 4350 5260

Notes:1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C2 Values in compliance with EN14511-3:20113 Evaporator water (in/out) = 12°C/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40°C/45°C.4 Evaporator water (in/out) = 12°C/7°C; Recovery unit water (in/out) = 40°C/45°C.5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.6 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.7 Unit in standard configuration/execution, without optional accessories.- Unavailable

Page 11: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

7

NECS / BGENERAL TECHNICAL DATA

NECS / B 2618 2818 3018 3218Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50PERFORMANCECOOLING ONLY (GROSS VALUE)Cooling capacity (1) kW 708 759 793 827Total power input (1) kW 249 261 279 296EER (1) 2,85 2,92 2,84 2,80ESEER (1) 4,18 4,27 4,20 4,07COOLING ONLY (EN14511 VALUE)Cooling capacity (1)(2) kW 705 757 791 824EER (1)(2) 2,80 2,88 2,81 2,76ESEER (1)(2) 3,98 4,10 4,03 3,90Cooling energy class C C C CCOOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 734 788 823 858Total power input (3) kW 241 252 270 286Desuperheater heating capacity (3) kW 201 211 228 242COOLING WITH TOTAL HEAT RECOVERYCooling capacity with total heat recovery (4) kW 732 780 825 872Total power input (4) kW 213 226 240 252Recovery heat exchanger capacity (4) kW 932 993 1050 1109EXCHANGERSHEAT EXCHANGER USER SIDE IN REFRIGERATIONWater flow (1) m³/h 122 131 137 142Pressure drop (1) kPa 54,9 42,7 46,7 50,6PARTIAL RECOVERY USER SIDE INREFRIGERATIONWater flow (3) m³/h 34,9 36,7 39,6 42,1Pressure drop (3) kPa 40,1 41,7 48,6 55,0HEAT EXCHANGER RECOVERY USER SIDE INREFRIGERATIONWater flow (4) m³/h 162 172 183 193Pressure drop (4) kPa 97,0 74,4 83,3 92,9COMPRESSORSN. of compressors N° 8 8 8 8Number of capacity N° 8 8 8 8No. of circuits N° 4 4 4 4Regulation STEPS STEPS STEPS STEPSMin. capacity step % 12.5 12.5 12.5 12.5Refrigerant R410A R410A R410A R410ARefrigerant charge kg 82,0 93,0 93,0 93,0Oil charge kg 50,0 50,0 50,0 50,0FANSQuantity N° 3 3 3 3Air flow m³/s 71,3 68,2 68,2 68,2Fans power kW 2,00 2,00 2,00 2,00NOISE LEVELNoise Pressure (5) dB(A) 65 66 66 66Noise Power (6) dB(A) 98 99 99 99SIZE AND WEIGHTA (7) mm 7430 7430 7430 7430B (7) mm 2260 2260 2260 2260H (7) mm 2450 2450 2450 2450Operating weight (7) kg 5300 5370 5400 5430

Notes:1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C2 Values in compliance with EN14511-3:20113 Evaporator water (in/out) = 12°C/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40°C/45°C.4 Evaporator water (in/out) = 12°C/7°C; Recovery unit water (in/out) = 40°C/45°C.5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.6 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.7 Unit in standard configuration/execution, without optional accessories.- Unavailable

Page 12: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

8

NECS / SLGENERAL TECHNICAL DATA

NECS / SL 1314 1414 1614 1715 1816 2015 2116 2316 2416 2418Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50PERFORMANCECOOLING ONLY (GROSS VALUE)Cooling capacity (1) kW 334 358 397 431 465 498 532 579 596 616Total power input (1) kW 129 137 153 168 183 192 206 220 230 245EER (1) 2,58 2,61 2,60 2,57 2,55 2,60 2,58 2,63 2,59 2,52ESEER (1) 4,29 4,31 4,21 4,33 4,36 4,26 4,37 4,38 4,29 4,32COOLING ONLY (EN14511 VALUE)Cooling capacity (1)(2) kW 332 357 396 430 463 496 531 577 594 614EER (1)(2) 2,55 2,58 2,56 2,53 2,51 2,57 2,55 2,60 2,56 2,49ESEER (1)(2) 4,10 4,15 4,03 4,14 4,15 4,12 4,19 4,20 4,12 4,15Cooling energy class D D D D D D D D D ECOOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 346 372 412 448 482 516 552 601 618 639Total power input (3) kW 125 133 148 163 177 185 199 213 222 236Desuperheater heating capacity (3) kW 109 115 130 142 154 162 174 186 194 208COOLING WITH TOTAL HEAT RECOVERYCooling capacity with total heat recovery (4) kW 365 390 436 473 514 545 585 628 655 686Total power input (4) kW 107 113 126 139 150 158 170 184 189 200Recovery heat exchanger capacity (4) kW 466 496 554 604 655 694 744 801 832 874EXCHANGERSHEAT EXCHANGER USER SIDE IN REFRIGERATIONWater flow (1) m³/h 57,4 61,7 68,4 74,3 80,1 85,7 91,6 99,7 103 106Pressure drop (1) kPa 47,8 39,2 48,2 43,0 50,0 35,2 40,3 40,8 43,1 41,6PARTIAL RECOVERY USER SIDE INREFRIGERATIONWater flow (3) m³/h 19,0 20,1 22,5 24,7 26,8 28,2 30,3 32,3 33,8 36,1Pressure drop (3) kPa 42,0 40,6 51,2 48,1 52,4 49,2 52,2 59,3 65,0 57,3HEAT EXCHANGER RECOVERY USER SIDE INREFRIGERATIONWater flow (4) m³/h 80,9 86,2 96,3 105 114 121 129 139 145 152Pressure drop (4) kPa 94,9 76,4 95,6 69,4 81,6 69,7 80,3 79,5 85,7 85,3COMPRESSORSN. of compressors N° 4 4 4 5 6 5 6 6 6 8Number of capacity N° 4 4 4 5 6 5 6 6 6 8No. of circuits N° 2 2 2 2 2 2 2 3 2 4Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPSMin. capacity step % 25 25 25 20 17 20 17 17 17 12.5Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410ARefrigerant charge kg 42,0 45,0 54,0 57,0 55,0 72,0 71,0 77,0 86,0 89,0Oil charge kg 25,0 25,0 25,0 32,0 38,0 32,0 38,0 38,0 38,0 50,0FANSQuantity N° 3 4 4 5 5 6 5 4 6 3Air flow m³/s 26,9 29,9 28,6 34,6 37,4 35,8 42,9 42,3 43,0 43,0Fans power kW 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00 1,00NOISE LEVELNoise Pressure (5) dB(A) 54 54 54 54 54 54 54 55 55 55Noise Power (6) dB(A) 86 86 86 87 87 87 87 88 88 88SIZE AND WEIGHTA (7) mm 5080 5080 5080 6255 6255 6255 7430 7430 7430 7430B (7) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (7) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (7) kg 3060 3160 3200 3900 4110 4190 4640 4730 4790 5410

Notes:1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C2 Values in compliance with EN14511-3:20113 Evaporator water (in/out) = 12°C/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40°C/45°C.4 Evaporator water (in/out) = 12°C/7°C; Recovery unit water (in/out) = 40°C/45°C.5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.6 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.7 Unit in standard configuration/execution, without optional accessories.- Unavailable

pgentilu
Evidenziato
pgentilu
Evidenziato
pgentilu
Evidenziato
Page 13: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

9

NECS / SLGENERAL TECHNICAL DATA

NECS / SL 2618 2818 3018 3218Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50PERFORMANCECOOLING ONLY (GROSS VALUE)Cooling capacity (1) kW 666 718 758 795Total power input (1) kW 258 275 288 306EER (1) 2,58 2,61 2,63 2,60ESEER (1) 4,39 4,36 4,39 4,27COOLING ONLY (EN14511 VALUE)Cooling capacity (1)(2) kW 664 716 755 792EER (1)(2) 2,55 2,58 2,60 2,56ESEER (1)(2) 4,19 4,19 4,21 4,09Cooling energy class D D D DCOOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 691 745 786 824Total power input (3) kW 250 266 279 296Desuperheater heating capacity (3) kW 218 231 243 259COOLING WITH TOTAL HEAT RECOVERYCooling capacity with total heat recovery (4) kW 732 780 825 872Total power input (4) kW 213 226 240 252Recovery heat exchanger capacity (4) kW 932 993 1050 1109EXCHANGERSHEAT EXCHANGER USER SIDE IN REFRIGERATIONWater flow (1) m³/h 115 124 130 137Pressure drop (1) kPa 48,7 38,2 42,6 46,8PARTIAL RECOVERY USER SIDE INREFRIGERATIONWater flow (3) m³/h 37,9 40,1 42,3 45,0Pressure drop (3) kPa 47,4 50,0 55,3 62,8HEAT EXCHANGER RECOVERY USER SIDE INREFRIGERATIONWater flow (4) m³/h 162 172 183 193Pressure drop (4) kPa 97,0 74,4 83,3 92,9COMPRESSORSN. of compressors N° 8 8 8 8Number of capacity N° 8 8 8 8No. of circuits N° 4 4 4 4Regulation STEPS STEPS STEPS STEPSMin. capacity step % 12.5 12.5 12.5 12.5Refrigerant R410A R410A R410A R410ARefrigerant charge kg 89,0 93,0 103 112Oil charge kg 50,0 50,0 50,0 50,0FANSQuantity N° 4 4 4 4Air flow m³/s 53,8 59,8 62,3 57,3Fans power kW 1,00 1,00 1,00 1,00NOISE LEVELNoise Pressure (5) dB(A) 56 57 57 57Noise Power (6) dB(A) 89 90 90 90SIZE AND WEIGHTA (7) mm 8605 9780 9780 9780B (7) mm 2260 2260 2260 2260H (7) mm 2450 2450 2450 2450Operating weight (7) kg 5810 6160 6200 6250

Notes:1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C2 Values in compliance with EN14511-3:20113 Evaporator water (in/out) = 12°C/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40°C/45°C.4 Evaporator water (in/out) = 12°C/7°C; Recovery unit water (in/out) = 40°C/45°C.5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.6 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.7 Unit in standard configuration/execution, without optional accessories.- Unavailable

Page 14: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

10

NECS / CAGENERAL TECHNICAL DATA

NECS / CA 1314 1414 1614 1715 1816 2015 2116 2316 2416 2418Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50PERFORMANCECOOLING ONLY (GROSS VALUE)Cooling capacity (1) kW 370 391 438 481 518 549 591 633 657 701Total power input (1) kW 120 125 142 154 166 177 189 204 212 225EER (1) 3,10 3,13 3,10 3,12 3,11 3,10 3,12 3,10 3,10 3,11ESEER (1) 4,45 4,48 4,39 4,54 4,50 4,42 4,48 4,48 4,37 4,44COOLING ONLY (EN14511 VALUE)Cooling capacity (1)(2) kW 369 390 436 479 515 547 589 630 655 699EER (1)(2) 3,04 3,08 3,04 3,07 3,05 3,06 3,07 3,06 3,05 3,06ESEER (1)(2) 4,22 4,28 4,17 4,30 4,24 4,23 4,28 4,27 4,16 4,22Cooling energy class B B B B B B B B B BCOOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 384 406 455 499 537 570 614 656 682 728Total power input (3) kW 116 121 137 149 161 172 184 198 206 219Desuperheater heating capacity (3) kW 92,4 97,4 112 121 131 140 149 161 168 173COOLING WITH TOTAL HEAT RECOVERYCooling capacity with total heat recovery (4) kW 365 390 436 473 514 545 585 628 655 686Total power input (4) kW 107 113 126 139 150 158 170 184 189 200Recovery heat exchanger capacity (4) kW 466 496 554 604 655 694 744 801 832 874EXCHANGERSHEAT EXCHANGER USER SIDE IN REFRIGERATIONWater flow (1) m³/h 63,8 67,4 75,5 82,8 89,1 94,5 102 109 113 121Pressure drop (1) kPa 59,0 46,8 58,7 53,5 61,9 42,9 49,8 48,6 52,5 54,0PARTIAL RECOVERY USER SIDE INREFRIGERATIONWater flow (3) m³/h 16,1 16,9 19,5 21,1 22,7 24,4 26,0 27,9 29,2 30,0Pressure drop (3) kPa 30,2 28,9 38,3 35,1 37,6 36,8 38,4 44,4 48,6 39,6HEAT EXCHANGER RECOVERY USER SIDE INREFRIGERATIONWater flow (4) m³/h 80,9 86,2 96,3 105 114 121 129 139 145 152Pressure drop (4) kPa 94,9 76,4 95,6 69,4 81,6 69,7 80,3 79,5 85,7 85,3COMPRESSORSN. of compressors N° 4 4 4 5 6 5 6 6 6 8Number of capacity N° 4 4 4 5 6 5 6 6 6 8No. of circuits N° 2 2 2 2 2 2 2 3 2 4Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPSMin. capacity step % 25 25 25 20 17 20 17 17 17 12.5Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410ARefrigerant charge kg 46,0 54,0 54,0 62,0 67,0 72,0 77,0 81,0 86,0 89,0Oil charge kg 25,0 25,0 25,0 32,0 38,0 32,0 38,0 38,0 38,0 50,0FANSQuantity N° 4 4 4 4 5 4 5 4 6 4Air flow m³/s 47,5 45,5 45,5 51,1 56,8 56,8 62,5 68,2 68,2 93,2Fans power kW 2,00 2,00 2,00 2,00 2,00 2,00 2,00 2,00 2,00 2,00NOISE LEVELNoise Pressure (5) dB(A) 65 65 65 64 65 65 65 66 66 66Noise Power (6) dB(A) 97 97 97 97 98 98 98 99 99 99SIZE AND WEIGHTA (7) mm 5080 5080 5080 6255 6255 6255 7430 7430 7430 9780B (7) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (7) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (7) kg 3060 3100 3130 3800 4050 4090 4540 4630 4690 5930

Notes:1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C2 Values in compliance with EN14511-3:20113 Evaporator water (in/out) = 12°C/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40°C/45°C.4 Evaporator water (in/out) = 12°C/7°C; Recovery unit water (in/out) = 40°C/45°C.5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.6 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.7 Unit in standard configuration/execution, without optional accessories.- Unavailable

Page 15: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

11

NECS / CAGENERAL TECHNICAL DATA

NECS / CA 2618 2818 3018 3218Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50PERFORMANCECOOLING ONLY (GROSS VALUE)Cooling capacity (1) kW 740 785 831 885Total power input (1) kW 239 250 266 283EER (1) 3,10 3,13 3,12 3,13ESEER (1) 4,46 4,50 4,49 4,45COOLING ONLY (EN14511 VALUE)Cooling capacity (1)(2) kW 737 782 828 881EER (1)(2) 3,04 3,09 3,07 3,07ESEER (1)(2) 4,22 4,30 4,28 4,22Cooling energy class B B B BCOOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 768 814 862 918Total power input (3) kW 232 243 258 274Desuperheater heating capacity (3) kW 185 195 209 224COOLING WITH TOTAL HEAT RECOVERYCooling capacity with total heat recovery (4) kW 732 780 825 872Total power input (4) kW 213 226 240 252Recovery heat exchanger capacity (4) kW 932 993 1050 1109EXCHANGERSHEAT EXCHANGER USER SIDE IN REFRIGERATIONWater flow (1) m³/h 127 135 143 152Pressure drop (1) kPa 60,0 45,6 51,1 58,0PARTIAL RECOVERY USER SIDE INREFRIGERATIONWater flow (3) m³/h 32,1 33,9 36,4 38,9Pressure drop (3) kPa 34,0 35,6 41,0 47,0HEAT EXCHANGER RECOVERY USER SIDE INREFRIGERATIONWater flow (4) m³/h 162 172 183 193Pressure drop (4) kPa 97,0 74,4 83,3 92,9COMPRESSORSN. of compressors N° 8 8 8 8Number of capacity N° 8 8 8 8No. of circuits N° 4 4 4 4Regulation STEPS STEPS STEPS STEPSMin. capacity step % 12.5 12.5 12.5 12.5Refrigerant R410A R410A R410A R410ARefrigerant charge kg 99,0 112 112 112Oil charge kg 50,0 50,0 50,0 50,0FANSQuantity N° 4 4 4 4Air flow m³/s 95,1 90,9 90,9 90,9Fans power kW 2,00 2,00 2,00 2,00NOISE LEVELNoise Pressure (5) dB(A) 66 67 67 67Noise Power (6) dB(A) 99 100 100 100SIZE AND WEIGHTA (7) mm 9780 9780 9780 9780B (7) mm 2260 2260 2260 2260H (7) mm 2450 2450 2450 2450Operating weight (7) kg 5970 6040 6070 6110

Notes:1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C2 Values in compliance with EN14511-3:20113 Evaporator water (in/out) = 12°C/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40°C/45°C.4 Evaporator water (in/out) = 12°C/7°C; Recovery unit water (in/out) = 40°C/45°C.5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.6 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.7 Unit in standard configuration/execution, without optional accessories.- Unavailable

Page 16: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

12

NECS / SL-CAGENERAL TECHNICAL DATA

NECS / SL-CA 1314 1414 1614 1715 1816 2015 2116 2316 2416 2418Power supply V/ph/Hz 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50 400/3/50PERFORMANCECOOLING ONLY (GROSS VALUE)Cooling capacity (1) kW 370 394 440 481 522 550 592 638 662 695Total power input (1) kW 119 126 142 154 167 177 189 204 213 223EER (1) 3,11 3,12 3,11 3,12 3,12 3,11 3,13 3,12 3,11 3,12ESEER (1) 4,57 4,56 4,44 4,54 4,58 4,52 4,60 4,59 4,53 4,58COOLING ONLY (EN14511 VALUE)Cooling capacity (1)(2) kW 369 393 438 480 520 549 590 636 660 693EER (1)(2) 3,07 3,08 3,06 3,08 3,08 3,08 3,08 3,08 3,06 3,09ESEER (1)(2) 4,38 4,39 4,27 4,39 4,40 4,35 4,40 4,39 4,33 4,43Cooling energy class B B B B B B B B B BCOOLING WITH PARTIAL RECOVERYCooling capacity (3) kW 384 409 457 499 541 571 614 662 687 721Total power input (3) kW 115 122 137 149 162 171 183 198 206 216Desuperheater heating capacity (3) kW 97,5 103 117 127 137 146 156 169 177 183COOLING WITH TOTAL HEAT RECOVERYCooling capacity with total heat recovery (4) kW 387 410 459 502 542 574 615 666 688 726Total power input (4) kW 104 111 124 135 147 155 167 179 186 195Recovery heat exchanger capacity (4) kW 485 515 576 629 681 720 772 834 864 909EXCHANGERSHEAT EXCHANGER USER SIDE IN REFRIGERATIONWater flow (1) m³/h 63,8 67,9 75,8 82,8 89,8 94,7 102 110 114 120Pressure drop (1) kPa 41,9 35,9 44,8 32,9 38,7 36,8 42,5 44,7 48,1 35,8PARTIAL RECOVERY USER SIDE INREFRIGERATIONWater flow (3) m³/h 16,9 17,9 20,3 22,1 23,9 25,4 27,2 29,3 30,7 31,8Pressure drop (3) kPa 33,6 32,3 41,4 38,5 41,6 39,9 42,0 48,9 53,7 44,6HEAT EXCHANGER RECOVERY USER SIDE INREFRIGERATIONWater flow (4) m³/h 84,3 89,5 100 109 118 125 134 145 150 158Pressure drop (4) kPa 73,2 62,5 78,2 57,4 67,2 64,2 73,8 77,7 83,3 62,4COMPRESSORSN. of compressors N° 4 4 4 5 6 5 6 6 6 8Number of capacity N° 4 4 4 5 6 5 6 6 6 8No. of circuits N° 2 2 2 2 2 2 2 3 2 4Regulation STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPS STEPSMin. capacity step % 25 25 25 20 17 20 17 17 17 12.5Refrigerant R410A R410A R410A R410A R410A R410A R410A R410A R410A R410ARefrigerant charge kg 53,0 67,0 67,0 77,0 81,0 86,0 91,0 96,0 98,0 98,0Oil charge kg 25,0 25,0 25,0 32,0 38,0 32,0 38,0 38,0 38,0 50,0FANSQuantity N° 4 5 5 5 6 5 6 4 7 4Air flow m³/s 39,7 42,9 41,2 45,3 49,4 49,4 53,5 57,7 57,7 65,9Fans power kW 1,10 1,10 1,10 1,10 1,10 1,10 1,10 1,10 1,10 1,10NOISE LEVELNoise Pressure (5) dB(A) 53 53 53 54 54 54 54 55 55 55Noise Power (6) dB(A) 86 86 86 87 87 87 87 88 88 88SIZE AND WEIGHTA (7) mm 6255 6255 6255 7430 7430 7430 8605 8605 8605 9780B (7) mm 2260 2260 2260 2260 2260 2260 2260 2260 2260 2260H (7) mm 2450 2450 2450 2450 2450 2450 2450 2450 2450 2450Operating weight (7) kg 3490 3700 3730 4400 4650 4510 4990 5360 5360 6100

Notes:1 Plant (side) cooling exchanger water (in/out) 12°C/7°C; Source (side) heat exchanger air (in) 35°C2 Values in compliance with EN14511-3:20113 Evaporator water (in/out) = 12°C/7°C; Condenser air (in) = 35°C; Desuperheater water (in/out) = 40°C/45°C.4 Evaporator water (in/out) = 12°C/7°C; Recovery unit water (in/out) = 40°C/45°C.5 Average sound pressure level, at 10m distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level.6 Sound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units.7 Unit in standard configuration/execution, without optional accessories.- Unavailable

Page 17: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS

4.2 COOLING CAPACITY PERFORMANCE

131430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

388 367 358 344 320 310 399 378 368 354 330 319 411 388 379 364 339 328

104 113 117 123 135 140 105 114 118 124 136 141 106 115 119 126 137 14266,8 63,2 61,6 59,3 55,1 53,4 68,8 65,0 63,4 61,0 56,7 55,0 70,7 66,8 65,2 62,7 58,3 56,564,8 57,9 55,1 50,9 44,1 41,3 68,6 61,3 58,4 54,0 46,7 43,8 72,5 64,8 61,7 57,0 49,3 46,3

Ta

Dpev 76,5 68,4 65,1 60,2 52,1 48,9 80,6 72,1 68,6 63,4 54,9 51,5 84,8 75,8 72,2 66,7 57,7 54,2Qev 72,6 68,7 67,0 64,4 59,9 58,0 74,6 70,5 68,8 66,1 61,5 59,6 76,5 72,3 70,6 67,8 63,1 61,1Pat 107 116 120 127 139 144 108 117 121 128 140 145 109 118 122 129 141 146Pf 422 399 389 374 348 337 433 409 399 384 357 346 444 420 409 394 366 355

9 10 11Tev

141430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

414 392 383 368 343 332 426 403 394 379 353 342 438 414 405 389 363 351

109 118 122 129 141 147 110 119 123 130 143 148 111 120 125 131 144 14971,3 67,5 65,9 63,4 59,0 57,2 73,4 69,4 67,8 65,2 60,7 58,9 75,4 71,4 69,7 67,0 62,4 60,552,4 46,9 44,7 41,4 35,9 33,7 55,5 49,7 47,3 43,8 38,0 35,7 58,6 52,5 50,0 46,3 40,2 37,7

Ta

Dpev 61,8 55,4 52,8 48,8 42,4 39,8 65,1 58,3 55,6 51,5 44,7 42,0 68,5 61,3 58,4 54,1 47,0 44,1Qev 77,5 73,3 71,6 68,9 64,1 62,2 79,5 75,2 73,5 70,7 65,8 63,8 81,5 77,2 75,3 72,5 67,5 65,5Pat 111 121 126 132 145 151 112 122 127 134 146 152 113 123 128 135 148 153Pf 450 426 416 400 372 361 461 437 426 410 382 370 473 448 437 421 392 380

9 10 11Tev

161430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

455 429 419 402 374 362 467 441 430 413 384 372 480 453 442 425 394 382

123 134 139 146 161 167 124 135 140 148 162 169 125 136 141 149 164 17078,3 73,9 72,1 69,2 64,3 62,3 80,4 75,9 74,1 71,2 66,1 64,0 82,6 78,0 76,1 73,1 67,9 65,763,1 56,2 53,5 49,4 42,6 39,9 66,6 59,4 56,5 52,2 45,0 42,2 70,2 62,7 59,6 55,0 47,5 44,5

Ta

Dpev 74,0 66,0 62,8 58,0 50,0 46,9 77,7 69,4 66,0 60,9 52,6 49,3 81,6 72,8 69,3 64,0 55,3 51,8Qev 84,7 80,0 78,1 75,0 69,7 67,5 86,9 82,1 80,0 76,9 71,5 69,2 89,0 84,1 82,0 78,8 73,2 70,9Pat 126 138 143 151 166 172 127 139 144 152 167 174 128 140 145 153 169 175Pf 492 465 453 436 405 392 504 476 465 446 415 402 517 488 476 457 425 412

9 10 11Tev

171530 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

502 475 463 446 414 401 517 488 477 458 426 413 531 502 490 471 438 424

133 145 150 159 174 181 135 147 152 160 176 182 136 148 153 162 177 18486,5 81,7 79,8 76,7 71,3 69,1 89,0 84,1 82,1 78,9 73,4 71,1 91,4 86,4 84,3 81,1 75,4 73,058,3 52,1 49,6 45,9 39,7 37,2 61,7 55,2 52,5 48,5 42,0 39,4 65,2 58,3 55,5 51,3 44,4 41,6

Ta

Dpev 68,8 61,5 58,5 54,1 46,8 43,9 72,5 64,7 61,6 57,0 49,3 46,3 76,2 68,1 64,8 59,9 51,9 48,7Qev 93,9 88,8 86,6 83,3 77,5 75,0 96,4 91,1 88,9 85,5 79,5 77,0 98,8 93,4 91,2 87,7 81,5 79,0Pat 137 149 155 163 179 186 138 151 156 165 180 187 140 152 158 166 182 189Pf 545 515 503 484 450 436 559 529 516 496 461 447 574 542 529 509 473 458

9 10 11Tev

181630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

548 519 506 487 453 439 564 534 521 501 467 452 581 549 536 516 480 465

143 156 161 170 186 193 144 157 163 172 188 195 145 159 164 173 190 19694,4 89,3 87,1 83,8 78,0 75,6 97,2 91,9 89,7 86,3 80,3 77,8 100,0 94,6 92,3 88,8 82,6 80,169,5 62,2 59,2 54,8 47,5 44,6 73,7 65,9 62,8 58,1 50,3 47,3 77,9 69,7 66,4 61,5 53,3 50,0

Ta

Dpev 82,3 73,7 70,2 65,0 56,3 52,8 86,8 77,7 74,0 68,5 59,4 55,7 91,5 81,8 78,0 72,2 62,5 58,7Qev 103 97,2 94,9 91,3 84,9 82,3 106 99,8 97,4 93,7 87,2 84,5 108 102 100,0 96,2 89,5 86,7Pat 147 160 166 175 191 198 148 162 168 177 193 200 150 163 169 178 194 201Pf 597 564 551 530 493 478 612 579 566 544 506 491 628 594 580 558 520 503

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

14ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 18: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS

COOLING CAPACITY PERFORMANCE

201530 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

576 545 532 511 476 461 592 560 547 526 489 474 608 575 561 540 502 487

154 167 173 182 200 208 155 168 174 184 202 210 156 170 176 186 204 21299,2 93,8 91,5 88,0 81,9 79,3 102 96,4 94,1 90,5 84,2 81,6 105 99,0 96,7 93,0 86,5 83,847,2 42,2 40,2 37,2 32,2 30,2 49,9 44,6 42,5 39,3 34,0 31,9 52,6 47,1 44,8 41,5 35,9 33,7

Ta

Dpev 55,5 49,6 47,2 43,7 37,9 35,6 58,3 52,2 49,7 46,0 39,9 37,4 61,3 54,8 52,2 48,3 41,9 39,3Qev 107 102 99,2 95,4 88,8 86,1 110 104 102 97,9 91,1 88,3 113 107 104 100 93,4 90,5Pat 157 171 177 187 206 214 159 173 179 189 207 215 160 174 180 190 209 217Pf 624 590 576 554 516 500 640 605 591 568 529 513 656 620 605 582 542 525

9 10 11Tev

211630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

623 589 575 554 515 499 641 606 592 569 530 514 659 623 608 585 545 528

163 177 183 194 212 220 164 179 185 195 214 222 166 180 187 197 216 224107 101 99,0 95,3 88,7 86,0 110 104 102 98,0 91,3 88,5 113 107 105 101 93,8 91,055,2 49,4 47,1 43,6 37,8 35,5 58,4 52,3 49,8 46,1 40,0 37,6 61,7 55,3 52,7 48,8 42,3 39,7

Ta

Dpev 65,1 58,3 55,6 51,4 44,6 41,9 68,6 61,4 58,5 54,2 47,0 44,2 72,1 64,6 61,6 57,0 49,5 46,5Qev 116 110 108 104 96,4 93,4 120 113 110 106 99,0 95,9 123 116 113 109 102 98,4Pat 167 182 189 199 218 226 169 184 190 201 220 228 170 185 192 202 221 230Pf 676 640 625 601 560 543 694 657 641 617 574 557 711 673 657 632 589 571

9 10 11Tev

231630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

663 626 611 587 546 529 681 644 628 604 561 543 700 661 645 620 576 558

178 194 201 212 233 242 180 196 203 214 235 244 182 198 205 216 237 246114 108 105 101 94,0 91,0 117 111 108 104 96,6 93,6 120 114 111 107 99,3 96,153,3 47,6 45,3 41,9 36,2 33,9 56,4 50,3 47,9 44,3 38,3 35,9 59,5 53,1 50,6 46,7 40,4 37,9

Ta

Dpev 62,7 56,0 53,3 49,3 42,6 39,9 65,9 58,9 56,1 51,8 44,8 42,0 69,3 61,9 58,9 54,4 47,1 44,2Qev 124 117 114 110 102 98,7 127 120 117 112 105 101 130 123 120 115 107 104Pat 183 199 207 218 239 249 185 201 208 220 242 251 186 203 210 222 244 253Pf 718 678 662 636 592 573 736 696 679 653 607 588 754 713 696 669 622 602

9 10 11Tev

241630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

694 657 642 618 575 558 714 676 660 635 591 573 733 694 678 652 608 589

183 198 205 217 238 247 185 200 207 219 240 249 186 202 209 221 242 251120 113 110 106 99,0 96,0 123 116 114 109 102 98,7 126 119 117 112 105 10158,6 52,5 50,0 46,3 40,2 37,8 61,9 55,5 52,9 49,0 42,5 40,0 65,3 58,5 55,8 51,7 44,9 42,2

Ta

Dpev 68,8 61,7 58,8 54,5 47,3 44,5 72,4 64,9 61,9 57,3 49,8 46,8 76,1 68,2 65,0 60,3 52,4 49,3Qev 130 123 120 115 107 104 133 126 123 118 110 107 136 129 126 121 113 110Pat 188 204 211 222 244 254 189 205 212 224 246 256 190 207 214 226 248 258Pf 752 712 695 669 624 605 771 730 713 687 640 620 791 748 731 704 656 636

9 10 11Tev

241830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

728 689 672 646 601 583 750 709 692 665 619 600 771 729 711 684 636 617

194 212 220 231 253 262 196 214 222 234 255 264 198 216 224 236 257 267125 119 116 111 103 100 129 122 119 115 107 103 133 126 122 118 110 10658,1 52,0 49,5 45,8 39,6 37,2 61,6 55,1 52,5 48,5 42,0 39,4 65,2 58,3 55,5 51,3 44,4 41,7

Ta

Dpev 68,9 61,6 58,6 54,2 46,9 44,0 72,6 64,9 61,8 57,2 49,5 46,4 76,5 68,4 65,1 60,2 52,1 48,9Qev 136 129 126 121 113 109 140 132 129 124 116 112 144 136 133 128 119 115Pat 200 218 226 238 260 269 202 220 228 240 262 271 204 222 230 242 264 273Pf 792 749 731 703 654 633 813 769 750 722 671 650 834 789 770 740 689 667

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

15ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 19: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS

COOLING CAPACITY PERFORMANCE

261830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

776 733 716 688 640 620 798 754 736 708 658 638 820 775 757 728 677 656

207 226 234 246 270 280 209 228 236 249 272 282 211 230 238 251 275 285134 126 123 118 110 107 137 130 127 122 113 110 141 134 130 125 117 11365,9 58,9 56,1 51,9 44,9 42,1 69,8 62,4 59,4 54,9 47,5 44,6 73,8 66,0 62,8 58,1 50,2 47,2

Ta

Dpev 77,9 69,6 66,3 61,3 53,0 49,8 82,1 73,4 69,9 64,6 55,9 52,4 86,4 77,2 73,5 68,0 58,8 55,2Qev 145 137 134 129 120 116 149 141 137 132 123 119 153 144 141 136 126 122Pat 213 232 240 253 277 287 215 234 242 256 279 290 217 236 245 258 282 292Pf 842 796 777 747 695 673 865 817 798 767 713 691 887 838 818 787 732 709

9 10 11Tev

281830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

831 786 767 738 687 666 855 809 789 759 707 685 878 831 811 780 727 704

217 236 245 258 283 293 219 238 247 261 285 296 221 241 249 263 288 299143 135 132 127 118 115 147 139 136 131 122 118 151 143 140 134 125 12151,1 45,8 43,6 40,4 35,0 32,9 54,1 48,4 46,2 42,7 37,0 34,8 57,2 51,2 48,8 45,2 39,2 36,8

Ta

Dpev 60,3 54,0 51,5 47,6 41,3 38,8 63,5 56,9 54,2 50,2 43,5 40,9 66,8 59,8 57,0 52,8 45,8 43,0Qev 155 147 143 138 129 125 159 151 147 142 132 128 163 155 151 145 135 131Pat 223 243 251 265 290 301 225 245 254 267 293 304 227 247 256 270 295 306Pf 902 853 833 802 746 723 925 876 855 823 766 743 949 898 876 843 786 761

9 10 11Tev

301830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

870 823 803 772 718 695 895 846 825 793 738 715 919 869 848 815 758 734

233 253 262 276 303 315 235 255 264 279 306 318 237 258 267 282 309 321150 142 138 133 124 120 154 146 142 137 127 123 158 150 146 140 131 12656,1 50,1 47,7 44,1 38,1 35,8 59,3 53,0 50,5 46,7 40,3 37,9 62,6 55,9 53,3 49,3 42,6 40,0

Ta

Dpev 66,0 59,0 56,1 51,9 44,9 42,2 69,4 62,0 59,1 54,6 47,3 44,4 72,9 65,2 62,1 57,4 49,7 46,7Qev 162 154 150 144 134 130 167 158 154 148 138 133 171 161 158 152 141 137Pat 239 260 269 284 312 324 241 262 272 287 315 327 243 264 274 289 317 329Pf 943 892 870 837 778 754 967 914 892 858 798 773 991 937 915 880 818 793

9 10 11Tev

321830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

909 858 837 804 747 723 934 882 860 827 768 743 959 905 883 849 788 763

246 267 277 293 322 334 248 270 280 296 325 338 250 273 283 299 328 341156 148 144 138 129 124 161 152 148 142 132 128 165 156 152 146 136 13161,2 54,6 51,9 47,9 41,3 38,7 64,6 57,6 54,8 50,6 43,7 40,9 68,1 60,8 57,8 53,4 46,1 43,2

Ta

Dpev 71,7 64,0 60,9 56,2 48,5 45,5 75,4 67,3 64,0 59,1 51,0 47,9 79,2 70,6 67,2 62,1 53,6 50,3Qev 169 160 156 150 139 135 174 164 160 154 143 138 178 168 164 158 146 142Pat 253 275 285 301 331 344 255 278 288 304 334 347 257 280 290 307 337 350Pf 984 929 906 871 809 783 1008 952 929 893 829 803 1033 975 951 914 850 823

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

16ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 20: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS

COOLING CAPACITY PERFORMANCE

131430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

401 381 373 360 337 327 413 393 384 370 347 337 425 404 395 381 357 347

101 109 113 119 129 134 102 110 114 120 130 135 102 111 115 120 131 13669,1 65,6 64,2 61,9 58,0 56,3 71,1 67,6 66,1 63,8 59,7 58,0 73,2 69,5 68,0 65,6 61,5 59,769,1 62,4 59,7 55,6 48,7 46,0 73,3 66,2 63,3 59,0 51,7 48,8 77,7 70,1 67,1 62,5 54,8 51,7

Ta

Dpev 82,1 74,2 70,9 66,1 58,0 54,7 86,7 78,3 74,9 69,8 61,2 57,8 91,4 82,6 79,0 73,6 64,6 61,0Qev 75,3 71,5 70,0 67,5 63,2 61,4 77,3 73,5 71,9 69,4 65,0 63,2 79,4 75,5 73,8 71,2 66,7 64,9Pat 103 112 115 121 132 137 104 112 116 122 133 138 105 113 117 123 134 139Pf 437 415 406 392 367 357 449 427 417 403 377 367 461 438 428 413 387 376

9 10 11Tev

141430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

423 402 394 380 356 346 436 414 405 391 367 357 448 426 417 403 377 367

106 114 118 124 135 140 107 115 119 125 137 141 107 116 120 126 138 14372,9 69,3 67,8 65,4 61,3 59,6 75,0 71,3 69,8 67,4 63,2 61,4 77,2 73,4 71,8 69,3 65,0 63,254,7 49,4 47,3 44,1 38,7 36,6 58,0 52,4 50,2 46,8 41,1 38,8 61,3 55,5 53,1 49,5 43,5 41,1

Ta

Dpev 64,8 58,6 56,1 52,3 46,0 43,5 68,4 61,9 59,2 55,3 48,6 45,9 72,0 65,2 62,4 58,2 51,2 48,4Qev 79,3 75,4 73,8 71,3 66,8 65,0 81,5 77,5 75,8 73,2 68,7 66,8 83,6 79,6 77,8 75,2 70,5 68,6Pat 108 117 121 127 138 144 109 118 122 128 139 144 110 118 122 129 140 145Pf 461 438 429 414 388 377 473 450 440 425 399 388 485 462 452 436 409 398

9 10 11Tev

161430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

476 452 442 426 399 387 489 465 454 438 410 398 503 478 467 451 422 410

120 129 133 140 154 159 121 130 134 142 155 161 122 131 135 143 156 16281,9 77,8 76,1 73,4 68,6 66,7 84,3 80,0 78,2 75,5 70,6 68,6 86,6 82,3 80,4 77,6 72,6 70,669,1 62,3 59,6 55,4 48,5 45,8 73,1 66,0 63,1 58,7 51,4 48,5 77,3 69,7 66,6 62,0 54,3 51,3

Ta

Dpev 81,5 73,5 70,3 65,5 57,4 54,1 85,8 77,5 74,1 69,0 60,5 57,1 90,3 81,5 77,9 72,6 63,6 60,1Qev 89,0 84,5 82,6 79,7 74,6 72,5 91,3 86,7 84,8 81,8 76,6 74,4 93,6 88,9 87,0 83,9 78,6 76,4Pat 122 132 136 144 157 163 123 133 137 145 158 164 124 134 138 146 159 165Pf 516 491 480 463 433 421 530 503 492 475 445 432 543 516 505 487 456 443

9 10 11Tev

171530 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

522 495 484 467 437 425 537 510 499 481 450 437 552 525 513 495 463 450

129 140 145 153 167 173 131 141 146 154 168 174 132 143 147 155 169 17689,8 85,3 83,4 80,4 75,2 73,1 92,5 87,8 85,9 82,8 77,5 75,3 95,1 90,3 88,3 85,2 79,7 77,562,9 56,7 54,2 50,4 44,2 41,6 66,7 60,1 57,5 53,5 46,8 44,2 70,6 63,7 60,9 56,6 49,6 46,8

Ta

Dpev 74,6 67,3 64,3 59,9 52,4 49,5 78,7 71,0 67,9 63,2 55,4 52,2 82,9 74,8 71,5 66,6 58,4 55,1Qev 97,8 92,9 90,8 87,6 82,0 79,6 100 95,4 93,3 90,0 84,2 81,8 103 97,9 95,8 92,4 86,5 84,0Pat 133 144 149 156 171 177 134 145 150 157 172 178 135 146 151 159 173 179Pf 568 539 527 509 476 462 583 554 541 522 489 475 598 568 556 536 502 488

9 10 11Tev

181630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

561 533 521 502 470 456 578 549 537 518 484 470 595 565 552 533 499 484

139 151 157 165 180 187 140 153 158 166 182 188 141 154 159 168 183 19096,5 91,7 89,6 86,5 80,9 78,6 99,5 94,5 92,4 89,1 83,4 81,0 102 97,3 95,1 91,7 85,8 83,472,7 65,6 62,7 58,3 51,0 48,2 77,2 69,6 66,5 61,9 54,2 51,1 81,8 73,8 70,5 65,6 57,5 54,2

Ta

Dpev 86,5 78,1 74,6 69,5 60,8 57,4 91,4 82,5 78,9 73,4 64,3 60,7 96,4 87,0 83,2 77,4 67,8 64,0Qev 105 100 97,8 94,4 88,3 85,8 108 103 101 97,0 90,8 88,2 111 106 103 99,6 93,3 90,6Pat 143 155 160 169 184 191 144 156 162 170 186 192 145 158 163 172 187 194Pf 612 581 568 548 513 498 628 597 584 563 527 512 645 613 599 578 541 526

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

17ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 21: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS

COOLING CAPACITY PERFORMANCE

201530 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

596 566 553 534 499 485 613 582 569 549 514 499 630 598 585 564 528 513

150 162 167 176 192 199 151 163 168 177 194 201 152 164 169 178 195 202103 97,4 95,3 91,9 85,9 83,5 106 100 98,0 94,5 88,5 85,9 109 103 101 97,2 91,0 88,450,6 45,6 43,6 40,5 35,5 33,4 53,5 48,2 46,1 42,9 37,6 35,4 56,5 51,0 48,7 45,4 39,7 37,5

Ta

Dpev 59,6 53,8 51,4 47,9 41,9 39,6 62,8 56,7 54,2 50,4 44,2 41,7 66,1 59,6 57,0 53,1 46,5 43,9Qev 111 106 104 99,9 93,5 90,8 114 109 106 103 96,0 93,2 117 111 109 105 98,5 95,7Pat 153 165 171 180 197 204 154 166 172 181 198 205 155 167 173 182 199 207Pf 647 615 601 580 543 527 664 631 617 595 557 541 681 647 632 610 571 555

9 10 11Tev

211630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

642 609 596 574 537 522 660 627 613 591 553 537 679 645 631 608 569 553

160 173 178 188 205 213 161 174 180 189 207 215 162 175 181 191 209 216110 105 103 98,9 92,5 89,8 114 108 106 102 95,3 92,5 117 111 109 105 98,0 95,258,5 52,8 50,4 46,9 41,1 38,7 62,0 55,9 53,5 49,8 43,6 41,1 65,6 59,2 56,6 52,7 46,1 43,5

Ta

Dpev 69,3 62,5 59,8 55,6 48,7 46,0 73,1 66,0 63,1 58,7 51,4 48,5 77,0 69,5 66,4 61,9 54,2 51,2Qev 120 114 112 108 101 97,9 123 117 115 111 104 101 127 120 118 114 106 103Pat 163 177 183 192 210 218 164 178 184 194 212 219 166 179 185 195 213 221Pf 698 663 648 625 585 568 716 681 665 642 601 584 735 698 683 659 617 599

9 10 11Tev

231630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

686 652 637 615 576 559 706 671 656 633 592 576 725 689 674 651 609 592

173 186 192 202 221 229 174 188 194 204 223 231 175 189 195 206 225 233118 112 110 106 99,1 96,2 122 115 113 109 102 99,1 125 119 116 112 105 10257,2 51,6 49,3 45,9 40,2 38,0 60,5 54,6 52,2 48,6 42,6 40,2 64,0 57,8 55,2 51,4 45,1 42,6

Ta

Dpev 67,5 61,0 58,3 54,3 47,7 45,0 71,2 64,3 61,5 57,3 50,3 47,5 74,9 67,7 64,7 60,3 52,9 50,0Qev 128 122 119 115 108 105 132 125 122 118 111 108 135 128 126 121 114 110Pat 176 190 197 207 226 235 178 192 198 208 228 236 179 193 199 210 229 238Pf 745 708 692 668 626 608 765 727 711 686 643 625 784 745 729 704 659 641

9 10 11Tev

241630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

713 678 662 639 598 581 734 697 681 657 615 597 754 716 700 676 632 614

180 194 200 211 230 239 181 195 202 212 232 241 182 197 203 214 234 243123 117 114 110 103 99,9 126 120 117 113 106 103 130 123 121 116 109 10661,8 55,8 53,3 49,6 43,4 40,9 65,4 59,0 56,4 52,5 46,0 43,4 69,1 62,4 59,6 55,5 48,6 45,9

Ta

Dpev 72,9 65,8 62,9 58,6 51,3 48,4 76,8 69,3 66,3 61,7 54,1 51,1 80,8 72,9 69,7 64,9 56,9 53,8Qev 133 127 124 120 112 109 137 130 127 123 115 112 140 133 130 126 118 115Pat 184 198 205 215 236 245 185 199 206 217 237 246 186 201 207 218 239 248Pf 774 735 719 694 650 631 794 755 738 712 667 648 814 774 757 730 684 665

9 10 11Tev

241830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

759 721 705 681 638 619 782 743 727 701 657 638 805 765 748 722 676 657

189 205 212 224 244 252 191 207 214 225 245 254 192 209 216 227 247 256131 124 121 117 110 107 135 128 125 121 113 110 139 132 129 124 116 11363,2 57,0 54,5 50,8 44,5 42,1 67,1 60,6 57,9 54,0 47,3 44,7 71,1 64,2 61,4 57,2 50,2 47,4

Ta

Dpev 75,2 68,0 65,0 60,6 53,1 50,2 79,5 71,8 68,7 64,0 56,2 53,1 83,8 75,8 72,5 67,6 59,3 56,0Qev 143 136 133 128 120 116 147 139 136 132 123 120 151 143 140 135 127 123Pat 194 210 218 229 249 258 196 212 219 230 251 260 197 214 221 232 253 261Pf 828 787 770 743 696 676 851 809 791 764 715 695 874 831 812 784 735 714

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

18ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 22: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS

COOLING CAPACITY PERFORMANCE

261830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

801 761 745 718 673 654 825 784 767 740 693 673 849 807 789 761 713 693

201 218 225 237 259 268 203 220 227 239 261 270 205 222 229 241 263 272138 131 128 124 116 113 142 135 132 127 119 116 146 139 136 131 123 11970,4 63,5 60,8 56,6 49,6 46,8 74,7 67,4 64,5 60,0 52,7 49,7 79,1 71,4 68,3 63,6 55,8 52,7

Ta

Dpev 83,6 75,5 72,2 67,3 59,0 55,7 88,2 79,7 76,3 71,1 62,4 58,9 93,0 84,0 80,4 74,9 65,8 62,1Qev 150 143 140 135 126 123 154 147 144 139 130 126 159 151 147 142 133 130Pat 206 223 231 243 265 274 208 225 232 244 266 276 209 226 234 246 268 278Pf 873 829 811 783 733 713 896 852 833 804 754 732 920 875 856 826 774 752

9 10 11Tev

281830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

849 807 789 762 714 694 874 831 813 785 735 715 899 855 836 807 757 736

212 229 236 248 271 281 213 230 238 250 273 283 215 232 240 252 275 285146 139 136 131 123 119 150 143 140 135 127 123 155 147 144 139 130 12753,4 48,2 46,1 43,0 37,8 35,7 56,6 51,1 48,9 45,6 40,1 37,9 59,9 54,1 51,8 48,3 42,4 40,1

Ta

Dpev 63,3 57,2 54,8 51,1 44,9 42,4 66,8 60,4 57,8 53,9 47,4 44,8 70,3 63,6 60,9 56,8 50,0 47,3Qev 159 151 148 143 134 130 163 155 152 147 138 134 168 160 156 151 141 137Pat 217 234 242 254 277 287 218 235 243 256 279 289 219 237 245 257 281 291Pf 924 878 859 830 778 756 949 902 883 852 799 777 973 926 906 875 821 798

9 10 11Tev

301830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

900 855 836 807 756 734 926 880 861 831 778 756 952 905 885 854 800 777

226 243 251 264 289 300 227 245 253 266 291 302 229 247 255 268 293 304155 147 144 139 130 126 159 151 148 143 134 130 164 156 152 147 138 13460,0 54,2 51,8 48,2 42,3 39,9 63,5 57,4 54,9 51,1 44,8 42,3 67,2 60,7 58,0 54,1 47,4 44,8

Ta

Dpev 70,9 64,1 61,3 57,1 50,1 47,3 74,8 67,6 64,6 60,2 52,9 50,0 78,7 71,1 68,1 63,4 55,7 52,6Qev 168 160 157 151 142 138 173 164 161 155 145 141 177 169 165 159 149 145Pat 231 249 257 270 295 306 232 250 259 272 297 308 233 252 260 274 299 311Pf 978 930 909 878 822 799 1004 954 933 901 844 821 1030 979 958 924 866 842

9 10 11Tev

321830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

960 912 892 860 805 781 988 938 917 885 828 804 1015 964 943 909 851 827

240 258 267 281 307 319 242 260 269 283 310 321 243 262 271 285 312 324165 157 153 148 138 134 170 161 158 152 143 138 175 166 162 157 147 14268,3 61,6 58,9 54,8 47,9 45,2 72,3 65,2 62,3 58,0 50,8 47,9 76,4 68,9 65,9 61,3 53,7 50,7

Ta

Dpev 80,5 72,7 69,5 64,7 56,7 53,5 84,8 76,6 73,2 68,2 59,8 56,4 89,2 80,5 77,0 71,7 62,9 59,4Qev 179 170 167 161 151 146 184 175 171 165 155 150 189 179 176 169 159 154Pat 245 264 273 287 314 326 246 266 275 289 317 329 248 268 277 291 319 331Pf 1042 990 968 934 874 849 1069 1016 993 958 897 872 1096 1042 1019 983 921 894

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

19ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 23: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS

COOLING CAPACITY PERFORMANCE

131430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

371 348 339 325 299 289 381 358 348 334 308 297 391 368 358 342 316 305

106 116 121 128 140 146 107 118 122 129 142 147 109 119 124 131 143 14963,8 60,0 58,4 55,9 51,5 49,7 65,6 61,7 60,0 57,4 52,9 51,1 67,4 63,3 61,6 59,0 54,4 52,459,1 52,2 49,4 45,3 38,5 35,8 62,5 55,1 52,2 47,8 40,6 37,8 65,9 58,1 55,0 50,4 42,9 39,9

Ta

Dpev 69,4 61,2 57,9 53,1 45,1 42,0 73,0 64,4 60,9 55,8 47,4 44,1 76,6 67,6 63,9 58,6 49,7 46,3Qev 69,2 65,0 63,2 60,5 55,8 53,8 70,9 66,6 64,8 62,0 57,2 55,2 72,7 68,3 66,4 63,5 58,6 56,5Pat 110 120 125 132 145 150 111 122 126 133 146 152 112 123 128 135 148 153Pf 402 377 367 351 324 312 412 387 376 360 332 320 422 396 385 369 340 328

9 10 11Tev

141430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

397 373 364 349 322 311 408 384 374 358 331 320 419 394 384 368 340 328

113 124 128 136 149 155 114 125 130 137 151 157 115 126 131 139 153 15868,3 64,3 62,6 60,0 55,4 53,5 70,2 66,1 64,3 61,7 57,0 55,0 72,1 67,8 66,1 63,3 58,5 56,548,1 42,6 40,4 37,1 31,7 29,5 50,8 45,0 42,6 39,2 33,4 31,2 53,6 47,4 45,0 41,3 35,2 32,9

Ta

Dpev 56,4 49,9 47,3 43,5 37,1 34,6 59,3 52,5 49,7 45,7 39,0 36,4 62,2 55,1 52,2 47,9 40,9 38,2Qev 74,0 69,6 67,8 65,0 60,0 58,0 75,9 71,4 69,5 66,6 61,5 59,4 77,7 73,1 71,2 68,2 63,0 60,9Pat 117 128 133 140 154 160 118 129 134 142 156 162 119 130 135 143 157 163Pf 430 404 394 377 348 337 440 414 403 387 357 345 451 424 413 396 366 353

9 10 11Tev

161430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

442 415 404 387 357 345 454 426 415 397 367 354 465 437 426 408 376 363

126 138 143 151 167 174 127 139 144 153 169 176 128 141 146 155 171 17876,0 71,5 69,6 66,6 61,5 59,3 78,1 73,4 71,4 68,4 63,1 61,0 80,1 75,3 73,3 70,2 64,8 62,659,5 52,6 49,8 45,7 38,9 36,3 62,8 55,5 52,6 48,2 41,1 38,3 66,1 58,4 55,4 50,8 43,3 40,3

Ta

Dpev 69,5 61,4 58,2 53,4 45,5 42,4 73,0 64,5 61,1 56,1 47,8 44,5 76,6 67,6 64,1 58,8 50,1 46,7Qev 82,2 77,2 75,2 72,0 66,5 64,2 84,2 79,1 77,0 73,8 68,1 65,7 86,2 81,0 78,9 75,5 69,7 67,3Pat 130 142 148 156 173 180 131 144 149 158 175 182 132 145 151 160 176 183Pf 477 448 437 418 386 372 489 459 447 428 395 382 500 470 458 438 405 391

9 10 11Tev

171530 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

480 451 439 420 387 374 493 463 451 431 398 384 506 476 463 443 408 394

138 151 157 166 183 190 140 153 159 168 185 192 141 155 161 170 187 19482,6 77,6 75,5 72,3 66,7 64,3 84,9 79,8 77,6 74,3 68,5 66,1 87,2 81,9 79,7 76,3 70,3 67,853,2 47,0 44,5 40,8 34,7 32,3 56,2 49,6 47,0 43,0 36,6 34,1 59,3 52,3 49,5 45,4 38,6 35,9

Ta

Dpev 62,4 55,1 52,1 47,7 40,6 37,8 65,6 57,8 54,8 50,2 42,6 39,7 68,8 60,7 57,5 52,6 44,7 41,6Qev 89,4 84,0 81,7 78,2 72,1 69,6 91,7 86,1 83,8 80,2 73,9 71,3 93,9 88,2 85,8 82,1 75,7 73,0Pat 143 157 162 172 189 196 144 158 164 174 191 198 146 160 166 175 192 200Pf 519 488 475 454 419 404 532 500 486 465 429 414 545 512 498 477 439 424

9 10 11Tev

181630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

518 486 473 452 417 402 532 500 486 465 428 413 547 513 499 477 440 424

150 165 171 181 198 205 152 167 173 183 200 207 154 169 175 185 202 21089,1 83,7 81,4 77,9 71,8 69,2 91,6 86,0 83,7 80,1 73,7 71,1 94,1 88,4 85,9 82,2 75,7 73,061,9 54,6 51,7 47,3 40,2 37,4 65,5 57,7 54,6 50,0 42,4 39,5 69,1 60,9 57,6 52,7 44,7 41,6

Ta

Dpev 72,8 64,1 60,7 55,5 47,1 43,8 76,6 67,5 63,8 58,4 49,5 46,0 80,4 70,8 67,0 61,3 51,9 48,3Qev 96,6 90,7 88,2 84,4 77,7 74,9 99,1 93,0 90,4 86,5 79,6 76,8 102 95,3 92,7 88,6 81,6 78,7Pat 156 171 177 187 204 212 157 172 179 189 206 214 159 174 181 191 208 216Pf 561 527 512 490 451 435 575 540 525 502 462 446 589 553 538 514 473 456

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

20ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 24: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS

COOLING CAPACITY PERFORMANCE

201530 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

553 520 506 485 447 432 568 534 520 498 459 443 583 548 533 511 471 455

157 172 179 189 209 218 159 174 181 192 211 220 160 176 183 194 214 22295,2 89,5 87,1 83,4 77,0 74,3 97,8 91,9 89,5 85,7 79,1 76,3 100 94,3 91,8 87,9 81,1 78,343,5 38,4 36,4 33,4 28,4 26,5 45,9 40,6 38,4 35,2 30,0 28,0 48,3 42,7 40,5 37,1 31,6 29,4

Ta

Dpev 50,8 44,9 42,5 39,0 33,2 31,0 53,4 47,2 44,7 41,0 34,9 32,5 56,0 49,4 46,8 43,0 36,6 34,1Qev 103 96,7 94,2 90,2 83,2 80,3 105 99,1 96,5 92,4 85,3 82,3 108 101 98,8 94,6 87,3 84,3Pat 162 178 185 196 216 225 164 180 187 198 218 227 165 181 188 200 220 229Pf 598 562 547 523 483 466 612 575 560 536 495 478 627 589 573 549 507 489

9 10 11Tev

211630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

592 556 541 518 478 461 608 571 556 532 491 474 624 586 571 546 504 486

169 185 192 204 224 233 171 188 195 206 227 235 173 190 197 208 229 238102 95,7 93,1 89,2 82,3 79,4 105 98,4 95,7 91,6 84,5 81,6 107 101 98,3 94,1 86,8 83,749,8 44,0 41,6 38,2 32,5 30,3 52,6 46,4 44,0 40,3 34,3 31,9 55,4 48,9 46,4 42,5 36,1 33,7

Ta

Dpev 58,4 51,5 48,8 44,7 38,0 35,4 61,3 54,1 51,3 47,0 40,0 37,2 64,4 56,8 53,8 49,3 41,9 39,0Qev 110 104 101 96,5 89,0 85,9 113 106 103 98,9 91,2 88,0 116 109 106 101 93,4 90,2Pat 175 192 199 211 231 240 177 194 201 213 234 243 179 196 203 215 236 245Pf 640 601 585 560 517 499 656 616 600 574 530 511 672 631 614 588 542 523

9 10 11Tev

231630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

643 605 589 564 521 503 660 621 605 579 535 517 678 637 621 595 549 530

181 198 205 218 240 250 183 200 208 220 243 252 185 202 210 222 245 255111 104 101 97,1 89,7 86,6 114 107 104 99,7 92,1 89,0 117 110 107 102 94,6 91,350,2 44,4 42,1 38,6 33,0 30,7 53,0 46,9 44,4 40,8 34,8 32,4 55,8 49,4 46,8 43,0 36,7 34,2

Ta

Dpev 58,7 52,0 49,3 45,2 38,6 36,0 61,7 54,6 51,7 47,5 40,5 37,8 64,7 57,3 54,3 49,8 42,5 39,7Qev 120 113 110 105 97,0 93,7 123 115 112 108 99,4 96,0 126 118 115 110 102 98,3Pat 186 204 212 225 248 258 188 206 214 227 250 260 190 208 216 229 253 263Pf 695 654 636 610 563 544 712 670 652 625 577 557 729 686 668 640 591 571

9 10 11Tev

241630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

662 622 606 580 535 517 680 639 622 596 550 531 698 656 638 611 564 545

188 206 214 227 251 261 190 209 217 230 254 264 192 211 219 232 256 267114 107 104 99,9 92,2 89,0 117 110 107 103 94,7 91,4 120 113 110 105 97,2 93,853,2 47,1 44,6 40,9 34,8 32,5 56,2 49,6 47,0 43,1 36,7 34,2 59,2 52,3 49,5 45,4 38,7 36,1

Ta

Dpev 62,2 55,0 52,1 47,8 40,7 37,9 65,3 57,7 54,7 50,2 42,7 39,8 68,5 60,5 57,3 52,6 44,8 41,8Qev 123 116 113 108 99,6 96,2 126 119 115 111 102 98,6 129 121 118 113 105 101Pat 194 213 221 235 259 270 196 215 224 237 262 272 198 217 226 239 264 275Pf 715 672 654 627 579 558 733 689 670 642 593 572 750 705 686 657 607 586

9 10 11Tev

241830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

688 645 627 599 551 531 707 663 644 616 566 546 726 681 662 632 581 560

200 220 229 242 265 275 203 223 231 245 268 278 205 225 234 247 271 281118 111 108 103 94,9 91,4 122 114 111 106 97,5 93,9 125 117 114 109 100 96,451,8 45,6 43,1 39,4 33,3 30,9 54,8 48,2 45,5 41,6 35,2 32,6 57,8 50,8 48,0 43,9 37,0 34,4

Ta

Dpev 60,9 53,5 50,6 46,2 39,0 36,2 64,1 56,3 53,1 48,5 41,0 38,0 67,3 59,0 55,8 50,9 43,0 39,8Qev 128 120 117 112 103 98,9 132 123 120 115 105 101 135 126 123 117 108 104Pat 208 228 237 250 274 284 210 231 239 253 276 286 213 233 242 255 279 289Pf 745 698 679 649 596 574 764 716 696 665 611 588 782 733 713 681 625 602

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

21ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 25: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS

COOLING CAPACITY PERFORMANCE

261830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

741 696 677 649 598 577 762 715 696 666 615 593 782 735 715 684 631 609

212 233 241 255 281 291 215 235 244 258 284 294 217 238 247 261 287 297128 120 117 112 103 99,3 131 123 120 115 106 102 135 126 123 118 109 10560,2 53,1 50,3 46,1 39,2 36,5 63,6 56,1 53,2 48,7 41,4 38,6 67,1 59,2 56,1 51,4 43,7 40,6

Ta

Dpev 70,7 62,3 59,0 54,1 45,9 42,8 74,3 65,5 62,0 56,8 48,3 44,9 78,0 68,8 65,1 59,6 50,7 47,2Qev 138 130 126 121 111 108 142 133 129 124 114 110 145 136 133 127 117 113Pat 220 241 250 264 289 300 222 243 252 267 292 303 224 246 255 269 295 306Pf 802 754 733 702 647 624 823 773 752 719 663 640 843 791 770 737 679 655

9 10 11Tev

281830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

796 749 729 698 645 623 818 769 749 718 663 640 840 790 769 737 681 657

226 248 257 272 299 310 229 250 260 275 302 314 231 253 263 278 305 317137 129 125 120 111 107 141 132 129 124 114 110 145 136 132 127 117 11346,9 41,5 39,3 36,1 30,8 28,8 49,5 43,8 41,6 38,2 32,6 30,4 52,2 46,2 43,8 40,2 34,4 32,0

Ta

Dpev 55,0 48,7 46,1 42,4 36,2 33,7 57,8 51,2 48,5 44,5 38,0 35,4 60,7 53,7 50,9 46,7 39,9 37,2Qev 148 140 136 130 120 116 152 143 139 133 123 119 156 147 143 137 126 122Pat 234 256 265 281 308 320 236 258 268 284 311 323 238 261 271 286 314 326Pf 861 810 789 756 698 674 883 830 809 775 716 691 904 851 828 794 733 708

9 10 11Tev

301830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

840 791 770 738 682 658 863 812 791 758 700 676 886 834 812 778 719 694

237 259 269 285 314 327 240 262 272 288 318 330 242 265 275 291 321 334145 136 133 127 117 113 149 140 136 130 121 116 153 144 140 134 124 12052,3 46,3 43,9 40,3 34,4 32,1 55,2 48,9 46,3 42,6 36,3 33,9 58,2 51,5 48,8 44,8 38,3 35,7

Ta

Dpev 61,3 54,2 51,4 47,2 40,3 37,6 64,4 57,0 54,0 49,6 42,3 39,5 67,5 59,7 56,6 52,0 44,4 41,4Qev 157 147 143 137 127 123 160 151 147 141 130 126 164 155 151 144 133 129Pat 245 268 278 295 324 337 247 271 281 298 328 340 250 273 284 300 331 344Pf 909 855 832 798 737 712 931 876 853 817 755 729 954 897 874 837 773 747

9 10 11Tev

321830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

883 830 808 774 714 689 907 852 830 795 733 708 930 875 851 815 752 726

251 275 286 303 334 348 254 278 289 306 338 352 256 281 292 310 342 356152 143 139 133 123 119 156 147 143 137 126 122 160 151 147 140 130 12557,7 51,0 48,3 44,3 37,8 35,2 60,9 53,8 51,0 46,8 39,8 37,1 64,2 56,7 53,7 49,3 42,0 39,1

Ta

Dpev 67,5 59,6 56,5 51,8 44,1 41,1 70,8 62,6 59,3 54,4 46,3 43,2 74,3 65,6 62,2 57,0 48,6 45,3Qev 164 154 150 144 133 128 168 158 154 148 136 131 172 162 158 151 139 135Pat 259 284 295 313 345 359 262 287 298 316 349 363 264 290 301 319 352 367Pf 954 897 873 836 771 745 977 918 894 856 790 763 1000 940 915 876 809 781

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

22ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 26: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SL-CANECS

COOLING CAPACITY PERFORMANCE

131430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

405 383 374 360 335 325 417 394 385 370 345 334 429 406 396 381 355 344

99,1 108 112 118 129 134 100 109 113 119 130 135 101 110 114 120 132 13669,7 65,9 64,3 61,9 57,7 55,9 71,8 67,9 66,3 63,8 59,4 57,6 73,9 69,9 68,2 65,7 61,1 59,350,0 44,8 42,6 39,5 34,2 32,2 53,1 47,5 45,3 41,9 36,3 34,1 56,3 50,3 48,0 44,4 38,5 36,2

Ta

Dpev 59,5 53,2 50,7 47,0 40,7 38,3 62,8 56,2 53,6 49,6 43,0 40,4 66,2 59,3 56,5 52,3 45,4 42,7Qev 76,0 71,9 70,2 67,5 62,9 61,0 78,1 73,9 72,1 69,4 64,6 62,7 80,2 75,9 74,1 71,3 66,4 64,4Pat 102 111 115 121 133 138 103 112 116 122 134 139 104 113 117 123 135 140Pf 441 417 407 392 365 354 453 429 419 403 375 364 465 440 430 414 385 373

9 10 11Tev

141430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

431 407 398 383 357 346 443 420 410 394 367 356 456 432 421 406 378 367

106 115 119 125 137 142 106 116 120 126 138 144 107 117 121 127 140 14574,1 70,1 68,5 65,9 61,4 59,5 76,3 72,2 70,5 67,9 63,3 61,3 78,5 74,3 72,6 69,8 65,1 63,142,9 38,4 36,6 33,9 29,4 27,7 45,4 40,7 38,8 35,9 31,2 29,3 48,1 43,1 41,1 38,1 33,1 31,1

Ta

Dpev 50,9 45,6 43,4 40,2 35,0 32,9 53,7 48,1 45,8 42,5 36,9 34,7 56,6 50,7 48,3 44,8 38,9 36,6Qev 80,7 76,4 74,6 71,8 66,9 64,9 83,0 78,5 76,7 73,8 68,8 66,7 85,2 80,6 78,7 75,8 70,6 68,5Pat 108 118 122 128 141 146 109 119 123 130 142 147 110 120 124 131 143 148Pf 469 444 433 417 389 377 482 456 445 428 399 387 494 468 457 440 410 397

9 10 11Tev

161430 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

481 455 444 428 398 386 495 468 457 440 410 398 509 482 470 453 422 409

119 128 133 140 154 160 120 130 134 142 155 162 120 131 135 143 157 16382,8 78,3 76,5 73,6 68,6 66,5 85,2 80,6 78,7 75,8 70,6 68,5 87,6 82,9 81,0 77,9 72,6 70,453,5 47,9 45,6 42,3 36,7 34,5 56,6 50,7 48,3 44,8 38,9 36,6 59,9 53,6 51,1 47,4 41,1 38,7

Ta

Dpev 63,2 56,6 54,0 50,0 43,5 40,9 66,6 59,7 56,9 52,7 45,8 43,1 70,1 62,8 59,9 55,5 48,3 45,4Qev 90,0 85,2 83,2 80,1 74,6 72,4 92,4 87,5 85,4 82,2 76,7 74,4 94,8 89,8 87,6 84,4 78,7 76,3Pat 121 132 136 144 158 164 122 133 137 145 159 166 123 134 138 146 161 167Pf 523 495 483 465 433 420 537 508 496 477 445 432 550 521 509 490 457 443

9 10 11Tev

171530 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

526 497 485 467 435 421 541 512 500 481 448 434 557 527 514 495 461 447

128 140 145 153 168 174 130 141 146 154 169 176 131 142 148 156 171 17790,5 85,6 83,5 80,4 74,8 72,5 93,2 88,1 86,0 82,8 77,1 74,7 95,9 90,7 88,5 85,2 79,3 76,939,3 35,1 33,5 31,0 26,9 25,3 41,7 37,3 35,5 32,9 28,5 26,8 44,1 39,5 37,6 34,8 30,2 28,4

Ta

Dpev 46,7 41,8 39,8 36,8 32,0 30,0 49,2 44,1 42,0 38,9 33,7 31,7 51,9 46,5 44,3 41,0 35,6 33,4Qev 98,6 93,3 91,0 87,6 81,6 79,1 101 95,8 93,5 90,0 83,8 81,3 104 98,4 96,0 92,4 86,1 83,5Pat 132 144 149 157 172 179 133 145 150 158 174 180 134 146 151 160 175 182Pf 572 541 529 509 474 459 588 556 543 522 487 472 604 571 557 536 500 484

9 10 11Tev

181630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

570 539 526 506 471 457 588 556 542 522 485 470 605 572 558 537 500 484

138 151 157 166 181 188 140 153 158 167 183 190 141 154 160 169 185 19198,1 92,8 90,6 87,1 81,1 78,6 101 95,6 93,3 89,8 83,6 81,0 104 98,5 96,1 92,5 86,1 83,446,2 41,3 39,4 36,4 31,6 29,6 49,1 43,9 41,8 38,7 33,5 31,5 52,1 46,6 44,3 41,0 35,6 33,4

Ta

Dpev 55,1 49,3 46,9 43,4 37,6 35,3 58,3 52,1 49,6 45,9 39,8 37,4 61,5 55,0 52,4 48,4 42,0 39,4Qev 107 101 98,9 95,1 88,5 85,8 110 104 102 97,8 91,0 88,2 113 107 104 100 93,5 90,6Pat 143 156 161 170 186 193 144 157 163 172 188 195 145 159 164 173 189 196Pf 622 588 574 552 514 498 640 605 590 568 528 512 657 621 606 583 543 526

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

23ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 27: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SL-CANECS

COOLING CAPACITY PERFORMANCE

201530 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

603 570 556 535 498 483 620 586 572 550 512 497 637 603 588 566 527 511

148 160 166 175 192 200 149 162 167 177 194 202 150 163 169 178 196 204104 98,1 95,7 92,1 85,7 83,1 107 101 98,5 94,7 88,2 85,5 110 104 101 97,4 90,7 87,944,1 39,4 37,6 34,8 30,1 28,3 46,7 41,8 39,8 36,8 31,9 30,0 49,4 44,1 42,1 38,9 33,7 31,7

Ta

Dpev 52,1 46,6 44,4 41,1 35,6 33,5 54,9 49,1 46,8 43,3 37,6 35,3 57,8 51,7 49,2 45,6 39,6 37,2Qev 113 107 104 100 93,2 90,4 116 109 107 103 95,7 92,8 119 112 110 105 98,2 95,2Pat 151 164 170 180 198 205 152 166 172 181 199 207 154 167 173 183 201 209Pf 654 619 604 581 541 525 672 635 620 597 556 539 689 652 636 612 570 553

9 10 11Tev

211630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

648 612 597 575 535 518 667 630 615 592 551 533 686 648 633 609 566 549

158 171 178 188 206 214 159 173 179 189 208 216 160 175 181 191 210 218111 105 103 98,9 92,0 89,2 115 109 106 102 94,8 91,8 118 112 109 105 97,5 94,551,0 45,5 43,4 40,1 34,7 32,6 54,0 48,3 46,0 42,5 36,8 34,6 57,2 51,1 48,7 45,0 39,0 36,6

Ta

Dpev 60,4 54,0 51,4 47,6 41,2 38,7 63,7 57,0 54,3 50,2 43,5 40,8 67,2 60,0 57,2 52,9 45,8 43,0Qev 121 115 112 108 100 97,2 125 118 115 111 103 99,8 128 121 118 114 106 102Pat 162 176 183 193 211 219 163 178 184 194 213 221 165 179 186 196 215 223Pf 705 666 650 625 582 564 724 684 668 642 598 579 743 702 685 659 614 595

9 10 11Tev

231630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

699 661 645 620 577 560 719 680 664 638 594 576 739 699 682 656 611 592

171 185 192 202 222 231 172 187 194 204 224 233 173 188 195 206 226 235120 114 111 107 99,4 96,3 124 117 114 110 102 99,2 127 120 117 113 105 10253,5 47,8 45,6 42,2 36,5 34,3 56,7 50,7 48,3 44,7 38,7 36,4 59,9 53,6 51,1 47,3 41,0 38,5

Ta

Dpev 63,3 56,6 53,9 49,9 43,3 40,7 66,7 59,7 56,8 52,6 45,6 42,9 70,2 62,8 59,9 55,4 48,1 45,2Qev 131 124 121 116 108 105 134 127 124 119 111 108 138 130 127 122 114 110Pat 175 190 197 208 228 237 176 192 199 210 230 239 178 193 200 211 232 241Pf 759 718 701 674 628 609 779 737 720 692 645 625 800 756 738 710 661 641

9 10 11Tev

241630 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

726 686 670 644 599 580 747 706 689 662 616 597 768 726 708 681 634 614

178 193 200 211 232 242 179 195 202 213 235 244 181 197 204 215 237 246125 118 115 111 103 99,9 129 122 119 114 106 103 132 125 122 117 109 10657,8 51,6 49,2 45,5 39,3 36,9 61,2 54,7 52,0 48,1 41,7 39,1 64,7 57,8 55,0 50,9 44,1 41,4

Ta

Dpev 68,2 61,0 58,1 53,7 46,5 43,7 71,9 64,2 61,2 56,6 49,0 46,0 75,6 67,6 64,4 59,5 51,6 48,5Qev 136 128 125 120 112 109 139 132 129 124 115 112 143 135 132 127 118 114Pat 182 198 206 217 239 248 184 200 207 219 241 250 185 202 209 221 243 252Pf 788 745 727 699 651 631 809 765 746 718 668 648 830 784 765 736 685 664

9 10 11Tev

241830 32 35 40 4225 25 30 32 35 40 42 25 30 32 35 40 42

6 7 8Tev

Pf

PatQevDpev

760 719 701 675 628 609 783 741 723 695 647 627 806 763 744 716 666 646

184 202 209 221 242 251 186 204 211 223 244 253 188 206 213 225 246 255131 124 121 116 108 105 135 128 124 120 111 108 139 131 128 123 115 11142,8 38,3 36,4 33,7 29,2 27,4 45,5 40,6 38,7 35,8 31,0 29,1 48,2 43,1 41,1 38,0 32,9 30,9

Ta

Dpev 51,0 45,6 43,5 40,2 34,8 32,7 53,9 48,2 45,9 42,5 36,8 34,6 56,9 50,9 48,5 44,9 38,9 36,5Qev 143 135 132 127 118 114 147 139 136 130 121 118 151 143 139 134 125 121Pat 190 208 215 227 248 257 192 209 217 229 250 259 194 211 219 231 252 262Pf 830 784 766 736 685 664 853 806 787 757 705 683 876 828 808 777 724 701

9 10 11Tev

Ta [°C] - Air temperatureTev [°C] - Plant (side) cooling exchanger output water temperature

Pat [kW] - Total power inputQev [m³/h] - Plant (side) heat exchanger water flowDpev [kPa] - Plant (side) cooling exchanger pressure drop

Pf [kW] - Cooling capacity

'-' Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta TNOTE: Data on grey background: unit switched to non-silenced operation

24ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 28: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS - D4.3 DESUPERHEATER CAPACITY

PERFORMANCE

1314

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

414 414 414 392 392 392 382 382 382 368 368 368 342 342 342 331 331 331101 101 101 110 110 110 114 114 114 121 121 121 132 132 132 137 137 13789,3 82,6 78,2 98,4 93,4 88,5 102 98,2 93,1 109 106 100 120 120 114 125 126 120

15,5 14,3 13,6 17,0 16,2 15,4 17,7 17,0 16,2 18,8 18,4 17,4 20,7 20,8 19,8 21,6 21,8 20,828,0 24,0 21,6 34,0 30,7 27,7 36,7 33,9 30,6 41,3 39,4 35,6 50,4 50,5 45,7 54,5 55,8 50,6

Tde

Ta

1414

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

442 442 442 418 418 418 408 408 408 393 393 393 366 366 366 355 355 355106 106 106 115 115 115 119 119 119 126 126 126 138 138 138 143 143 14394,1 87,1 82,4 103 98,2 93,1 107 103 97,8 114 111 105 126 126 120 131 133 126

16,3 15,1 14,3 17,9 17,0 16,2 18,6 17,9 17,0 19,8 19,3 18,3 21,8 21,9 20,8 22,7 23,0 21,926,8 23,0 20,7 32,4 29,3 26,4 35,0 32,4 29,2 39,4 37,6 33,9 48,1 48,3 43,7 52,2 53,4 48,4

Tde

Ta

1614

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

485 485 485 458 458 458 446 446 446 429 429 429 398 398 398 386 386 386120 120 120 131 131 131 135 135 135 143 143 143 157 157 157 163 163 163108 100 94,7 119 113 107 123 119 112 131 128 121 145 145 138 151 153 145

18,7 17,4 16,5 20,6 19,6 18,6 21,4 20,6 19,5 22,7 22,2 21,1 25,1 25,2 24,0 26,2 26,5 25,235,5 30,4 27,3 42,7 38,7 34,8 46,2 42,7 38,5 52,1 49,7 44,8 63,9 64,1 58,0 69,4 71,0 64,4

Tde

Ta

1715

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

536 536 536 507 507 507 494 494 494 475 475 475 442 442 442 428 428 428130 130 130 142 142 142 147 147 147 155 155 155 170 170 170 176 176 176116 108 102 128 122 115 133 128 121 141 138 131 156 156 148 162 164 156

20,2 18,7 17,7 22,2 21,1 20,0 23,1 22,2 21,1 24,5 23,9 22,7 27,0 27,1 25,8 28,1 28,5 27,132,1 27,6 24,8 38,9 35,2 31,7 42,0 38,8 35,0 47,3 45,1 40,7 57,7 57,9 52,4 62,5 64,0 58,0

Tde

Ta

1816

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

586 586 586 554 554 554 541 541 541 520 520 520 484 484 484 469 469 469140 140 140 152 152 152 158 158 158 166 166 166 182 182 182 189 189 189124 114 108 136 129 123 142 136 129 150 147 139 166 166 158 173 174 166

21,4 19,8 18,8 23,6 22,5 21,3 24,6 23,6 22,4 26,1 25,4 24,2 28,7 28,8 27,4 29,9 30,2 28,833,4 28,7 25,7 40,7 36,8 33,2 44,0 40,7 36,7 49,6 47,3 42,7 60,3 60,5 54,8 65,2 66,7 60,5

Tde

Ta

2015

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

614 614 614 581 581 581 567 567 567 545 545 545 507 507 507 492 492 492150 150 150 163 163 163 169 169 169 178 178 178 195 195 195 203 203 203134 124 117 147 140 132 153 147 139 162 158 150 179 179 170 187 189 179

23,2 21,5 20,4 25,4 24,2 23,0 26,4 25,4 24,1 28,1 27,4 26,0 31,1 31,1 29,6 32,4 32,8 31,233,4 28,7 25,7 40,1 36,3 32,7 43,3 40,1 36,1 48,8 46,6 42,0 59,8 60,0 54,4 65,0 66,5 60,3

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

25ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 29: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS - DDESUPERHEATER CAPACITY

PERFORMANCE

2116

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

665 665 665 629 629 629 614 614 614 591 591 591 550 550 550 533 533 533159 159 159 173 173 173 179 179 179 189 189 189 207 207 207 215 215 215141 131 124 155 147 140 161 155 147 171 167 158 189 189 180 197 199 189

24,5 22,7 21,5 26,9 25,6 24,3 27,9 26,9 25,5 29,6 29,0 27,5 32,8 32,8 31,2 34,1 34,5 32,934,1 29,3 26,3 41,2 37,3 33,6 44,5 41,2 37,1 50,1 47,8 43,1 61,2 61,4 55,6 66,3 67,9 61,5

Tde

Ta

2316

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

707 707 707 668 668 668 652 652 652 626 626 626 582 582 582 564 564 564174 174 174 190 190 190 196 196 196 207 207 207 227 227 227 236 236 236156 145 137 172 163 154 178 171 162 189 185 175 209 209 199 218 220 210

27,1 25,1 23,8 29,7 28,3 26,8 30,9 29,7 28,2 32,8 32,0 30,4 36,3 36,3 34,6 37,8 38,2 36,441,8 35,9 32,2 50,3 45,6 41,0 54,4 50,3 45,3 61,3 58,4 52,8 75,0 75,3 68,2 81,5 83,4 75,6

Tde

Ta

2416

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

741 741 741 701 701 701 684 684 684 659 659 659 614 614 614 595 595 595179 179 179 194 194 194 201 201 201 212 212 212 232 232 232 241 241 241159 147 139 174 165 156 181 173 164 192 187 177 212 212 202 221 223 212

27,5 25,5 24,1 30,1 28,7 27,2 31,3 30,1 28,6 33,2 32,4 30,8 36,7 36,8 35,0 38,3 38,7 36,943,1 37,0 33,2 51,7 46,8 42,1 55,8 51,6 46,5 62,8 59,9 54,1 77,0 77,2 69,9 83,6 85,6 77,6

Tde

Ta

2418

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

778 778 778 735 735 735 718 718 718 690 690 690 642 642 642 622 622 622190 190 190 207 207 207 215 215 215 226 226 226 247 247 247 256 256 256166 154 146 183 174 165 191 183 174 202 197 187 223 223 212 232 234 223

28,8 26,7 25,3 31,8 30,2 28,7 33,0 31,8 30,2 35,0 34,2 32,5 38,6 38,7 36,8 40,2 40,6 38,736,5 31,3 28,1 44,4 40,2 36,2 48,0 44,4 40,0 54,0 51,5 46,5 65,7 65,9 59,7 71,0 72,6 65,8

Tde

Ta

2618

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

828 828 828 783 783 783 764 764 764 734 734 734 683 683 683 662 662 662203 203 203 221 221 221 228 228 228 241 241 241 263 263 263 273 273 273179 165 156 197 187 177 204 196 186 217 212 201 239 239 228 249 252 239

30,9 28,7 27,2 34,1 32,4 30,8 35,4 34,1 32,3 37,6 36,7 34,9 41,5 41,5 39,5 43,2 43,7 41,631,6 27,1 24,3 38,3 34,7 31,2 41,4 38,3 34,5 46,6 44,4 40,1 56,8 57,0 51,6 61,4 62,9 57,0

Tde

Ta

2818

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

887 887 887 839 839 839 819 819 819 788 788 788 734 734 734 711 711 711212 212 212 231 231 231 239 239 239 252 252 252 276 276 276 287 287 287188 174 165 207 197 186 215 207 196 228 223 211 252 252 240 263 265 252

32,6 30,2 28,6 35,8 34,1 32,4 37,3 35,8 34,0 39,5 38,6 36,7 43,7 43,8 41,6 45,5 46,0 43,833,0 28,3 25,4 39,8 36,1 32,5 43,0 39,8 35,9 48,4 46,2 41,7 59,2 59,4 53,8 64,1 65,6 59,5

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

26ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 30: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS - DDESUPERHEATER CAPACITY

PERFORMANCE

3018

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

928 928 928 877 877 877 856 856 856 823 823 823 766 766 766 742 742 742227 227 227 247 247 247 256 256 256 270 270 270 296 296 296 308 308 308203 188 178 223 212 201 232 223 211 246 240 228 272 272 259 284 287 272

35,2 32,6 30,9 38,7 36,8 34,9 40,2 38,6 36,7 42,6 41,6 39,6 47,2 47,3 45,0 49,1 49,7 47,338,4 33,0 29,6 46,3 41,9 37,8 50,1 46,3 41,7 56,4 53,8 48,6 69,0 69,2 62,7 74,9 76,6 69,5

Tde

Ta

3218

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

969 969 969 915 915 915 892 892 892 858 858 858 797 797 797 771 771 771240 240 240 261 261 261 271 271 271 286 286 286 314 314 314 327 327 327216 200 189 237 226 214 247 237 225 262 256 242 290 290 276 303 306 291

37,5 34,7 32,9 41,1 39,1 37,1 42,8 41,1 39,0 45,4 44,3 42,1 50,3 50,4 47,9 52,4 53,0 50,543,5 37,4 33,5 52,4 47,5 42,8 56,7 52,4 47,3 63,9 60,9 55,0 78,4 78,7 71,2 85,2 87,2 79,0

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

27ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 31: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS - DDESUPERHEATER CAPACITY

PERFORMANCE

1314

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

407 407 407 384 384 384 360 360 360 334 334 334 - - - - - -107 107 107 116 116 116 126 126 126 138 138 138 - - - - - -90,7 86,1 81,6 99,9 97,4 92,4 110 110 105 122 125 119 - - - - - -

15,7 14,9 14,2 17,3 16,9 16,1 19,1 19,1 18,2 21,1 21,7 20,7 - - - - - -28,8 26,1 23,5 35,0 33,4 30,2 42,8 42,9 38,8 52,2 55,0 50,0 - - - - - -

Tde

Ta

1414

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

430 430 430 406 406 406 381 381 381 354 354 354 - - - - - -112 112 112 121 121 121 132 132 132 145 145 145 - - - - - -95,7 90,9 86,1 105 103 97,4 116 116 110 129 132 125 - - - - - -

16,6 15,8 15,0 18,2 17,8 16,9 20,1 20,2 19,2 22,3 22,9 21,8 - - - - - -27,7 25,1 22,6 33,6 32,0 28,9 41,0 41,1 37,2 50,2 52,9 48,0 - - - - - -

Tde

Ta

1614

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

482 482 482 455 455 455 426 426 426 395 395 395 - - - - - -126 126 126 137 137 137 150 150 150 165 165 165 - - - - - -110 105 99,2 121 118 112 134 134 127 149 152 145 - - - - - -

19,1 18,2 17,2 21,0 20,5 19,5 23,2 23,2 22,1 25,7 26,4 25,2 - - - - - -36,8 33,3 30,0 44,5 42,4 38,3 54,3 54,5 49,4 66,9 70,5 64,0 - - - - - -

Tde

Ta

1715

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

529 529 529 499 499 499 467 467 467 433 433 433 - - - - - -137 137 137 149 149 149 163 163 163 178 178 178 - - - - - -119 113 107 131 128 121 145 145 138 160 164 156 - - - - - -

20,6 19,6 18,6 22,7 22,2 21,1 25,1 25,1 23,9 27,8 28,5 27,2 - - - - - -33,6 30,4 27,4 40,8 38,9 35,1 49,8 49,9 45,2 60,9 64,2 58,3 - - - - - -

Tde

Ta

1816

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

569 569 569 537 537 537 502 502 502 466 466 466 - - - - - -148 148 148 161 161 161 176 176 176 192 192 192 - - - - - -128 121 115 141 138 131 156 156 148 172 176 168 - - - - - -

22,1 21,1 20,0 24,5 23,9 22,7 27,0 27,1 25,7 29,8 30,6 29,2 - - - - - -35,8 32,4 29,2 43,7 41,6 37,6 53,3 53,4 48,4 64,9 68,4 62,1 - - - - - -

Tde

Ta

2015

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

604 604 604 570 570 570 533 533 533 494 494 494 - - - - - -158 158 158 172 172 172 187 187 187 206 206 206 - - - - - -138 131 124 152 148 140 167 167 159 186 190 181 - - - - - -

23,9 22,7 21,6 26,2 25,6 24,4 29,0 29,1 27,7 32,2 33,0 31,5 - - - - - -35,3 32,0 28,8 42,7 40,7 36,8 52,2 52,3 47,4 64,2 67,7 61,4 - - - - - -

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

28ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 32: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS - DDESUPERHEATER CAPACITY

PERFORMANCE

2116

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

651 651 651 614 614 614 574 574 574 532 532 532 - - - - - -169 169 169 184 184 184 200 200 200 219 219 219 - - - - - -147 139 132 162 157 149 178 178 170 197 202 193 - - - - - -

25,4 24,2 22,9 28,0 27,3 26,0 30,9 31,0 29,5 34,2 35,1 33,5 - - - - - -36,8 33,3 30,0 44,6 42,5 38,4 54,5 54,6 49,5 66,7 70,3 63,8 - - - - - -

Tde

Ta

2316

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

696 696 696 656 656 656 615 615 615 570 570 570 - - - - - -182 182 182 198 198 198 216 216 216 237 237 237 - - - - - -158 150 142 174 169 161 192 192 182 213 218 207 - - - - - -

27,4 26,0 24,7 30,1 29,4 27,9 33,2 33,3 31,7 36,8 37,8 36,0 - - - - - -42,7 38,6 34,8 51,6 49,2 44,4 63,0 63,2 57,2 77,4 81,6 74,1 - - - - - -

Tde

Ta

2416

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

723 723 723 682 682 682 638 638 638 592 592 592 - - - - - -189 189 189 206 206 206 225 225 225 247 247 247 - - - - - -165 157 149 182 177 168 201 201 191 223 228 217 - - - - - -

28,6 27,2 25,8 31,5 30,7 29,2 34,8 34,8 33,2 38,6 39,6 37,7 - - - - - -46,7 42,3 38,1 56,4 53,8 48,6 69,0 69,2 62,7 84,9 89,5 81,2 - - - - - -

Tde

Ta

2418

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

771 771 771 728 728 728 682 682 682 632 632 632 - - - - - -201 201 201 219 219 219 238 238 238 259 259 259 - - - - - -169 161 152 187 182 173 206 206 196 227 233 222 - - - - - -

29,3 27,8 26,4 32,3 31,6 30,0 35,7 35,7 34,0 39,4 40,4 38,5 - - - - - -37,7 34,1 30,7 45,9 43,8 39,6 56,0 56,2 50,9 68,2 71,9 65,3 - - - - - -

Tde

Ta

2618

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

813 813 813 768 768 768 719 719 719 667 667 667 - - - - - -213 213 213 232 232 232 253 253 253 276 276 276 - - - - - -181 172 163 200 195 185 221 221 210 244 250 238 - - - - - -

31,4 29,9 28,3 34,6 33,8 32,1 38,2 38,3 36,4 42,2 43,4 41,3 - - - - - -32,5 29,4 26,5 39,5 37,7 34,0 48,2 48,4 43,8 58,9 62,1 56,4 - - - - - -

Tde

Ta

2818

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

862 862 862 814 814 814 763 763 763 709 709 709 - - - - - -224 224 224 243 243 243 265 265 265 290 290 290 - - - - - -192 182 172 211 205 195 233 233 221 258 264 251 - - - - - -

33,2 31,6 30,0 36,5 35,6 33,9 40,3 40,4 38,4 44,6 45,8 43,6 - - - - - -34,1 30,9 27,8 41,3 39,4 35,6 50,4 50,5 45,8 61,7 65,0 59,0 - - - - - -

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

29ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 33: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS - DDESUPERHEATER CAPACITY

PERFORMANCE

3018

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

913 913 913 862 862 862 807 807 807 749 749 749 - - - - - -238 238 238 258 258 258 282 282 282 309 309 309 - - - - - -206 196 185 226 221 209 250 250 238 277 284 270 - - - - - -

35,6 33,9 32,2 39,2 38,3 36,4 43,3 43,4 41,3 48,0 49,3 46,9 - - - - - -39,4 35,7 32,1 47,6 45,4 41,0 58,1 58,3 52,8 71,4 75,2 68,3 - - - - - -

Tde

Ta

3218

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

973 973 973 918 918 918 859 859 859 796 796 796 - - - - - -252 252 252 274 274 274 300 300 300 329 329 329 - - - - - -220 209 198 242 236 224 268 268 254 297 305 290 - - - - - -

38,2 36,3 34,5 42,0 41,0 38,9 46,4 46,5 44,2 51,5 52,8 50,3 - - - - - -45,2 40,9 36,8 54,6 52,0 47,0 66,7 66,9 60,6 82,1 86,5 78,5 - - - - - -

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

30ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 34: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS - DDESUPERHEATER CAPACITY

PERFORMANCE

1314

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

396 396 396 372 372 372 362 362 362 346 346 346 338 338 338 327 327 327104 104 104 114 114 114 118 118 118 125 125 125 130 130 130 135 135 13596,8 89,6 84,7 107 101 96,1 111 107 101 118 115 109 122 122 116 127 128 121

16,8 15,5 14,7 18,5 17,6 16,7 19,2 18,5 17,6 20,4 19,9 19,0 21,1 21,1 20,1 21,9 22,2 21,132,9 28,3 25,4 40,1 36,3 32,7 43,4 40,1 36,1 48,8 46,5 42,0 51,9 52,1 47,2 56,2 57,5 52,1

Tde

Ta

1414

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

423 423 423 398 398 398 388 388 388 372 372 372 362 362 362 351 351 351111 111 111 121 121 121 126 126 126 133 133 133 139 139 139 144 144 144103 94,8 89,7 113 107 102 118 113 107 125 122 115 129 129 123 135 136 129

17,8 16,4 15,6 19,6 18,6 17,7 20,4 19,6 18,6 21,6 21,1 20,1 22,4 22,4 21,3 23,3 23,6 22,431,8 27,3 24,5 38,7 35,0 31,5 41,9 38,7 34,9 47,2 45,0 40,6 50,6 50,8 46,0 54,8 56,1 50,9

Tde

Ta

1614

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

471 471 471 442 442 442 431 431 431 412 412 412 406 406 406 393 393 393123 123 123 135 135 135 140 140 140 148 148 148 153 153 153 159 159 159115 106 100 127 120 114 132 126 120 140 137 130 143 143 136 149 151 143

19,9 18,4 17,4 21,9 20,8 19,8 22,8 21,9 20,8 24,3 23,7 22,5 24,8 24,8 23,6 25,9 26,2 24,939,9 34,2 30,7 48,5 43,9 39,5 52,6 48,6 43,8 59,4 56,7 51,2 62,1 62,3 56,4 67,5 69,1 62,6

Tde

Ta

1715

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

512 512 512 481 481 481 468 468 468 448 448 448 437 437 437 423 423 423135 135 135 148 148 148 154 154 154 163 163 163 169 169 169 176 176 176126 117 110 139 132 125 145 139 132 154 150 142 158 158 150 165 166 158

21,8 20,2 19,2 24,1 22,9 21,7 25,1 24,1 22,9 26,6 26,0 24,7 27,4 27,5 26,1 28,5 28,9 27,537,7 32,3 29,0 45,8 41,5 37,3 49,6 45,8 41,3 55,9 53,3 48,1 59,4 59,6 53,9 64,3 65,8 59,7

Tde

Ta

1816

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

552 552 552 518 518 518 504 504 504 482 482 482 471 471 471 455 455 455147 147 147 161 161 161 167 167 167 177 177 177 184 184 184 191 191 191137 127 120 151 144 136 157 151 143 167 162 154 172 172 163 179 180 171

23,7 22,0 20,8 26,2 24,9 23,6 27,2 26,2 24,9 28,9 28,2 26,8 29,8 29,8 28,4 30,9 31,3 29,841,1 35,3 31,7 50,1 45,3 40,8 54,1 50,0 45,1 60,8 58,0 52,4 64,7 64,9 58,8 69,9 71,5 64,8

Tde

Ta

2015

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

589 589 589 554 554 554 539 539 539 516 516 516 508 508 508 492 492 492154 154 154 168 168 168 175 175 175 185 185 185 191 191 191 199 199 199144 133 126 158 150 142 165 158 150 175 171 162 179 179 170 187 189 179

24,9 23,0 21,8 27,4 26,1 24,8 28,5 27,4 26,1 30,3 29,6 28,2 31,0 31,1 29,6 32,3 32,7 31,138,3 32,9 29,5 46,6 42,2 38,0 50,5 46,7 42,1 57,1 54,5 49,2 59,7 59,8 54,2 64,8 66,4 60,1

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

31ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 35: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS - DDESUPERHEATER CAPACITY

PERFORMANCE

2116

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

631 631 631 593 593 593 577 577 577 552 552 552 538 538 538 521 521 521165 165 165 181 181 181 188 188 188 199 199 199 208 208 208 216 216 216154 143 135 170 162 153 177 170 161 188 183 174 195 195 185 203 205 194

26,8 24,8 23,5 29,5 28,1 26,6 30,7 29,5 28,0 32,6 31,8 30,3 33,7 33,7 32,1 35,1 35,5 33,840,8 35,0 31,4 49,6 44,9 40,5 53,7 49,7 44,8 60,6 57,8 52,2 64,7 64,9 58,8 70,1 71,8 65,1

Tde

Ta

2316

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

685 685 685 644 644 644 627 627 627 601 601 601 588 588 588 570 570 570177 177 177 193 193 193 201 201 201 213 213 213 221 221 221 230 230 230165 152 144 181 172 163 189 181 172 201 196 186 207 207 196 215 218 207

28,5 26,4 25,0 31,4 29,9 28,4 32,7 31,5 29,9 34,8 34,0 32,3 35,8 35,9 34,1 37,3 37,7 35,946,4 39,8 35,7 56,3 51,0 45,9 61,0 56,4 50,8 68,9 65,7 59,3 73,1 73,3 66,4 79,4 81,2 73,6

Tde

Ta

2416

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

705 705 705 663 663 663 645 645 645 618 618 618 608 608 608 589 589 589184 184 184 202 202 202 210 210 210 222 222 222 229 229 229 238 238 238172 159 151 190 180 171 198 190 180 210 205 194 215 215 204 224 226 215

29,8 27,6 26,2 32,9 31,3 29,7 34,2 32,9 31,2 36,4 35,5 33,8 37,2 37,3 35,4 38,8 39,2 37,350,6 43,5 39,0 61,5 55,7 50,2 66,7 61,7 55,6 75,4 72,0 65,0 78,8 79,1 71,6 85,7 87,7 79,5

Tde

Ta

2418

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

733 733 733 688 688 688 668 668 668 639 639 639 630 630 630 609 609 609196 196 196 215 215 215 224 224 224 236 236 236 243 243 243 252 252 252184 170 161 203 193 183 212 203 193 224 219 208 228 228 217 238 240 228

31,9 29,6 28,0 35,2 33,5 31,8 36,7 35,2 33,5 38,9 38,0 36,1 39,6 39,6 37,7 41,1 41,6 39,644,8 38,5 34,5 54,6 49,5 44,6 59,1 54,7 49,3 66,5 63,4 57,3 68,9 69,1 62,6 74,5 76,2 69,1

Tde

Ta

2618

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

790 790 790 742 742 742 722 722 722 691 691 691 675 675 675 653 653 653208 208 208 228 228 228 236 236 236 250 250 250 260 260 260 270 270 270194 179 169 214 203 192 222 213 202 236 230 218 243 243 231 253 255 243

33,5 31,1 29,4 37,0 35,2 33,4 38,5 37,0 35,1 40,8 39,9 37,9 42,1 42,2 40,1 43,8 44,3 42,237,1 31,8 28,6 45,2 40,9 36,8 48,9 45,2 40,7 55,0 52,5 47,4 58,5 58,7 53,2 63,3 64,8 58,8

Tde

Ta

2818

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

848 848 848 798 798 798 777 777 777 745 745 745 725 725 725 702 702 702221 221 221 242 242 242 251 251 251 266 266 266 278 278 278 288 288 288205 190 180 226 215 204 235 226 214 250 244 231 259 259 246 269 272 258

35,5 32,9 31,2 39,2 37,3 35,4 40,7 39,2 37,2 43,3 42,2 40,1 44,8 44,9 42,7 46,6 47,2 44,939,2 33,6 30,2 47,6 43,1 38,8 51,5 47,6 42,9 58,0 55,3 50,0 62,2 62,4 56,5 67,4 69,0 62,5

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

32ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 36: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS - DDESUPERHEATER CAPACITY

PERFORMANCE

3018

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

896 896 896 843 843 843 821 821 821 786 786 786 766 766 766 742 742 742232 232 232 254 254 254 263 263 263 279 279 279 292 292 292 303 303 303216 200 189 238 226 214 247 238 225 263 256 243 272 272 259 284 287 272

37,4 34,6 32,8 41,2 39,2 37,2 42,9 41,2 39,1 45,5 44,5 42,3 47,2 47,2 45,0 49,1 49,7 47,343,3 37,2 33,4 52,6 47,6 42,9 56,9 52,6 47,5 64,2 61,3 55,3 69,0 69,2 62,7 74,9 76,6 69,4

Tde

Ta

3218

25 30 32 35 40 42

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

941 941 941 884 884 884 861 861 861 824 824 824 811 811 811 786 786 786245 245 245 269 269 269 279 279 279 296 296 296 306 306 306 318 318 318229 212 201 253 240 228 263 253 240 280 273 259 286 286 272 299 301 287

39,7 36,8 34,9 43,8 41,7 39,6 45,6 43,9 41,7 48,5 47,4 45,0 49,6 49,7 47,3 51,7 52,3 49,849,0 42,0 37,7 59,5 53,9 48,5 64,5 59,6 53,8 73,0 69,6 62,8 76,2 76,5 69,3 82,9 84,8 76,9

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

33ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 37: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SL-CANECS - DDESUPERHEATER CAPACITY

PERFORMANCE

1314

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

409 409 409 384 384 384 358 358 358 335 335 335 - - - - - -106 106 106 115 115 115 126 126 126 137 137 137 - - - - - -95,6 90,8 86,0 105 103 97,5 116 116 110 126 129 123 - - - - - -

16,6 15,8 15,0 18,3 17,8 16,9 20,1 20,2 19,2 21,9 22,4 21,4 - - - - - -32,1 29,0 26,2 39,0 37,2 33,6 47,5 47,6 43,1 55,9 59,0 53,5 - - - - - -

Tde

Ta

1414

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

435 435 435 409 409 409 381 381 381 357 357 357 - - - - - -112 112 112 122 122 122 134 134 134 146 146 146 - - - - - -101 96,0 90,9 111 108 103 123 123 117 134 137 130 - - - - - -

17,5 16,6 15,8 19,3 18,8 17,9 21,3 21,3 20,3 23,1 23,8 22,6 - - - - - -30,9 28,0 25,2 37,5 35,8 32,3 45,7 45,9 41,5 54,1 57,0 51,7 - - - - - -

Tde

Ta

1614

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

486 486 486 457 457 457 426 426 426 400 400 400 - - - - - -125 125 125 137 137 137 150 150 150 163 163 163 - - - - - -114 109 103 126 123 117 139 139 132 151 155 148 - - - - - -

19,8 18,9 17,9 21,8 21,3 20,3 24,2 24,2 23,0 26,2 26,9 25,6 - - - - - -39,7 35,9 32,4 48,1 45,9 41,4 58,9 59,1 53,5 69,4 73,1 66,4 - - - - - -

Tde

Ta

1715

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

531 531 531 499 499 499 465 465 465 436 436 436 - - - - - -137 137 137 149 149 149 164 164 164 177 177 177 - - - - - -125 118 112 137 134 127 152 152 144 164 168 160 - - - - - -

21,6 20,5 19,5 23,8 23,2 22,1 26,3 26,3 25,0 28,4 29,2 27,8 - - - - - -36,8 33,3 30,0 44,7 42,6 38,5 54,5 54,7 49,5 63,8 67,3 61,1 - - - - - -

Tde

Ta

1816

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

576 576 576 541 541 541 504 504 504 473 473 473 - - - - - -148 148 148 162 162 162 177 177 177 191 191 191 - - - - - -135 128 121 149 145 137 164 164 156 177 181 173 - - - - - -

23,3 22,2 21,1 25,7 25,1 23,9 28,4 28,4 27,0 30,6 31,5 30,0 - - - - - -39,7 35,9 32,4 48,3 46,1 41,6 58,8 59,0 53,4 68,6 72,3 65,6 - - - - - -

Tde

Ta

2015

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

608 608 608 571 571 571 532 532 532 499 499 499 - - - - - -156 156 156 171 171 171 188 188 188 204 204 204 - - - - - -143 136 129 158 154 146 175 175 166 189 194 185 - - - - - -

24,8 23,6 22,4 27,3 26,7 25,4 30,3 30,3 28,8 32,8 33,7 32,1 - - - - - -38,2 34,6 31,1 46,3 44,2 39,9 56,8 56,9 51,6 66,7 70,3 63,8 - - - - - -

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

34ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 38: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SL-CANECS - DDESUPERHEATER CAPACITY

PERFORMANCE

2116

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

654 654 654 614 614 614 571 571 571 536 536 536 - - - - - -168 168 168 183 183 183 201 201 201 218 218 218 - - - - - -153 146 138 169 165 156 187 187 177 202 207 197 - - - - - -

26,5 25,3 24,0 29,3 28,6 27,2 32,3 32,4 30,8 35,0 35,9 34,2 - - - - - -40,2 36,4 32,7 48,8 46,5 42,0 59,6 59,8 54,1 69,7 73,5 66,7 - - - - - -

Tde

Ta

2316

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

705 705 705 662 662 662 617 617 617 579 579 579 - - - - - -181 181 181 198 198 198 217 217 217 235 235 235 - - - - - -165 157 149 182 178 169 202 202 192 219 224 213 - - - - - -

28,7 27,3 25,9 31,6 30,8 29,3 34,9 35,0 33,3 37,9 38,9 37,0 - - - - - -46,8 42,4 38,2 56,8 54,2 48,9 69,6 69,8 63,2 81,7 86,1 78,2 - - - - - -

Tde

Ta

2416

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

733 733 733 687 687 687 640 640 640 601 601 601 - - - - - -189 189 189 206 206 206 227 227 227 246 246 246 - - - - - -173 165 156 191 186 177 211 211 201 229 235 223 - - - - - -

30,0 28,6 27,1 33,1 32,3 30,7 36,6 36,7 34,9 39,7 40,7 38,8 - - - - - -51,4 46,5 41,9 62,4 59,5 53,7 76,5 76,7 69,5 89,8 94,6 85,9 - - - - - -

Tde

Ta

2418

30 35 40 45 50 55

35 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45

PfPatPtde

QdeDpde

768 768 768 721 721 721 671 671 671 630 630 630 - - - - - -197 197 197 216 216 216 236 236 236 255 255 255 - - - - - -179 171 162 198 193 183 218 218 208 236 242 230 - - - - - -

31,1 29,6 28,1 34,3 33,5 31,8 37,8 37,9 36,1 40,9 42,0 40,0 - - - - - -42,5 38,5 34,7 51,8 49,4 44,6 63,0 63,2 57,2 73,5 77,4 70,3 - - - - - -

Tde

Ta

Ta [°C] - Source (side) cooling exchanger air temperaturePf (kW) - Cooling capacity (Plant side cooling exchanger water in/out 12/7 °C)Pat (kW) - Total power inputPtde (kW) - Heat recovery thermal capacityQde (m3/h) - Plant (side) cooling exchanger recovery water flowDpde (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating range

NOTE: Data on grey background: unit switched to non-silenced operationWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

Tde (°C) - Plant (side) heat exchanger recovery output water temperature

35ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 39: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS - R

4.4 RECOVERY CAPACITY PERFORMANCE

131435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

397 376 353 409 388 365 422 400 376 435 412 388 447 424 400 460 436 41159,3 59,3 59,3 61,0 61,0 61,0 62,7 62,7 62,7 64,4 64,4 64,4 66,1 66,1 66,1 67,8 67,8 67,850,9 50,9 50,9 54,0 54,0 54,0 57,0 57,0 57,0 60,2 60,2 60,2 63,4 63,4 63,4 66,7 66,7 66,7

479 466 454 492 479 466 505 492 478 518 504 490 532 517 502 545 530 514

87,8 96,7 107 88,3 97,2 107 88,8 97,7 108 89,2 10898,1 89,7 98,6 109 90,1 99,0 109

83,0 80,9 78,8 85,3 83,1 80,9 87,5 85,3 83,0 89,8 87,5 85,1 92,1 89,7 87,2 94,4 91,9 89,399,8 95,0 90,1 105 100 94,9 111 105 99,9 117 111 105 123 117 110 129 122 116

141435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

423 401 378 436 414 390 450 427 402 463 440 414 477 452 427 490 465 43963,4 63,4 63,4 65,2 65,2 65,2 67,0 67,0 67,0 68,9 68,9 68,9 70,7 70,7 70,7 72,5 72,5 72,541,4 41,4 41,4 43,8 43,8 43,8 46,3 46,3 46,3 48,8 48,8 48,8 51,5 51,5 51,5 54,1 54,1 54,1

510 497 483 524 510 496 538 523 508 552 536 521 565 550 534 579 563 54792,8 102 112 93,2 102 113 93,7 103 113 94,1 114103 94,4 104 114 94,8 104 115

88,4 86,2 83,9 90,8 88,5 86,2 93,1 90,8 88,4 95,5 93,1 90,6 97,9 95,4 92,8 100 97,7 95,080,4 76,5 72,6 84,8 80,6 76,4 89,4 84,9 80,4 94,0 89,2 84,5 98,8 93,7 88,7 104 98,3 93,0

161435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

473 448 422 487 462 436 502 476 449 517 490 462 531 505 476 546 519 49069,2 69,2 69,2 71,2 71,2 71,2 73,1 73,1 73,1 75,0 75,0 75,0 76,9 76,9 76,9 78,8 78,8 78,849,4 49,4 49,4 52,2 52,2 52,2 55,0 55,0 55,0 58,0 58,0 58,0 60,9 60,9 60,9 64,0 64,0 64,0

571 556 540 586 570 554 601 585 568 616 599 582 631 614 596 646 628 610105 114 126 105 115 126 106 115 127 106 127116 106 116 128 107 116 128

99,0 96,4 93,9 102 98,9 96,3 104 101 98,8 107 104 101 109 106 104 112 109 106101 95,8 90,9 106 101 95,6 112 106 100 117 111 105 123 117 111 129 122 116

171535 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

514 487 458 531 503 473 547 519 488 563 534 503 580 550 518 596 566 53376,7 76,7 76,7 78,9 78,9 78,9 81,1 81,1 81,1 83,3 83,3 83,3 85,5 85,5 85,5 87,7 87,7 87,737,0 37,0 37,0 39,2 39,2 39,2 41,4 41,4 41,4 43,7 43,7 43,7 46,0 46,0 46,0 48,4 48,4 48,4

622 605 588 638 621 604 655 638 619 672 654 635 689 670 651 706 686 666

114 125 138 115 126 139 115 127 140 116 140127 116 128 141 117 128 141

108 105 102 111 108 105 114 111 108 116 113 110 119 116 113 122 119 11673,0 69,4 65,9 77,0 73,2 69,4 81,2 77,1 73,0 85,4 81,0 76,7 89,8 85,1 80,5 94,2 89,3 84,4

181635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

558 529 498 576 546 514 595 564 531 613 581 547 631 599 564 650 616 58183,8 83,8 83,8 86,3 86,3 86,3 88,8 88,8 88,8 91,3 91,3 91,3 93,7 93,7 93,7 96,2 96,2 96,244,3 44,3 44,3 46,9 46,9 46,9 49,7 49,7 49,7 52,5 52,5 52,5 55,3 55,3 55,3 58,3 58,3 58,3

673 655 638 692 673 655 710 692 672 729 710 689 748 728 707 767 746 724122 135 149 122 135 150 123 136 150 124 151137 124 137 151 125 138 152

117 114 111 120 117 114 123 120 117 126 123 120 130 126 123 133 129 12685,6 81,5 77,3 90,4 86,0 81,6 95,4 90,7 85,9 101 95,5 90,4 106 100 95,0 111 105 99,7

201535 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

592 561 528 610 578 545 628 596 561 647 614 578 665 631 595 683 649 61288,0 88,0 88,0 90,5 90,5 90,5 93,0 93,0 93,0 95,4 95,4 95,4 97,9 97,9 97,9 100 100 10037,2 37,2 37,2 39,3 39,3 39,3 41,5 41,5 41,5 43,7 43,7 43,7 46,0 46,0 46,0 48,3 48,3 48,3

715 695 676 734 714 694 753 732 711 771 750 729 790 768 746 809 786 763131 143 158 132 144 158 132 144 159 133 160145 133 146 160 134 146 161

124 121 118 127 124 121 130 127 124 134 130 127 137 133 130 140 136 13373,6 69,9 66,3 77,5 73,6 69,7 81,6 77,4 73,3 85,7 81,2 76,9 89,9 85,2 80,7 94,2 89,3 84,5

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

36ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 40: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS - R

RECOVERY CAPACITY PERFORMANCE

211635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

635 602 567 655 621 585 675 641 603 696 660 622 716 679 640 736 699 65995,3 95,3 95,3 98,0 98,0 98,0 101 101 101 104 104 104 106 106 106 109 109 10943,6 43,6 43,6 46,1 46,1 46,1 48,8 48,8 48,8 51,4 51,4 51,4 54,2 54,2 54,2 57,0 57,0 57,0

766 746 725 787 766 744 808 786 764 829 806 783 849 826 802 870 846 821

140 153 169 140 154 170 141 155 170 142 171155 142 156 172 143 156 172

133 129 126 136 133 129 140 136 133 144 140 136 147 143 139 151 147 14384,6 80,4 76,3 89,2 84,7 80,3 94,0 89,2 84,5 98,9 93,8 88,8 104 98,5 93,2 109 103 97,7

231635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

683 647 609 704 667 628 725 688 648 746 708 667 768 728 687 789 749 706101 101 101 104 104 104 107 107 107 110 110 110 112 112 112 115 115 11541,9 41,9 41,9 44,3 44,3 44,3 46,7 46,7 46,7 49,3 49,3 49,3 51,8 51,8 51,8 54,4 54,4 54,4

825 803 781 847 824 801 869 845 821 891 866 842 913 887 862 935 908 882152 166 183 153 167 184 153 168 185 154 186168 155 169 186 155 170 187

143 139 136 147 143 139 151 147 143 154 150 146 158 154 150 162 158 15383,8 79,6 75,5 88,3 83,8 79,5 92,9 88,2 83,5 97,7 92,6 87,7 103 97,2 92,0 107 102 96,3

241635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

710 674 634 732 695 655 754 716 675 776 737 695 798 758 715 820 779 736106 106 106 109 109 109 112 112 112 115 115 115 118 118 118 121 121 12146,3 46,3 46,3 49,0 49,0 49,0 51,7 51,7 51,7 54,5 54,5 54,5 57,3 57,3 57,3 60,3 60,3 60,3

857 834 811 880 856 832 902 878 853 925 899 874 947 921 895 970 943 916157 171 188 157 172 189 158 172 190 158 190173 159 173 191 159 174 192

148 145 141 152 148 145 156 152 148 160 156 152 164 160 155 168 164 15990,4 85,8 81,5 95,2 90,4 85,7 100 95,0 90,1 105 99,8 94,5 110 105 99,1 116 110 104

241835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

745 706 664 769 729 686 793 752 708 818 775 730 842 799 753 867 822 775111 111 111 115 115 115 118 118 118 121 121 121 124 124 124 128 128 12845,8 45,8 45,8 48,5 48,5 48,5 51,3 51,3 51,3 54,2 54,2 54,2 57,2 57,2 57,2 60,2 60,2 60,2

898 875 851 923 899 874 948 923 897 973 947 920 998 971 943 1024 995 966

163 180 199 164 181 200 164 181 201 165 201182 166 183 202 167 184 203

156 152 148 160 156 152 164 160 156 169 164 160 173 168 164 177 173 16889,5 85,2 80,9 94,5 89,9 85,3 99,8 94,8 89,8 105 99,8 94,5 111 105 99,3 116 110 104

261835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

795 753 708 820 777 732 845 802 755 871 826 778 897 851 802 922 875 825118 118 118 122 122 122 125 125 125 129 129 129 132 132 132 136 136 13651,9 51,9 51,9 54,9 54,9 54,9 58,1 58,1 58,1 61,3 61,3 61,3 64,6 64,6 64,6 68,0 68,0 68,0

959 933 908 985 959 932 1011 984 956 1038 1009 980 1064 1035 1005 1090 1060 1029175 192 212 175 193 213 176 194 214 177 215195 178 196 216 179 196 217

166 162 158 171 166 162 175 171 166 180 175 170 184 179 175 189 184 179102 97,0 92,1 108 102 97,0 114 108 102 120 113 107 126 119 113 132 125 118

281835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

847 802 755 874 828 780 900 854 804 927 880 829 954 906 854 981 932 878127 127 127 131 131 131 134 134 134 138 138 138 142 142 142 145 145 14540,4 40,4 40,4 42,7 42,7 42,7 45,2 45,2 45,2 47,6 47,6 47,6 50,2 50,2 50,2 52,8 52,8 52,8

1022 995 967 1049 1021 993 1077 1048 1018 1105 1074 1044 1132 1101 1069 1160 1128 1095186 204 225 187 205 226 188 206 227 189 228207 190 208 229 190 209 230

177 173 168 182 177 172 187 182 177 191 186 181 196 191 186 201 196 19078,3 74,4 70,6 82,6 78,4 74,4 87,0 82,6 78,2 91,5 86,8 82,2 96,2 91,2 86,3 101 95,7 90,5

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

37ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 41: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS - R

RECOVERY CAPACITY PERFORMANCE

301835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

896 849 799 924 876 825 952 903 851 980 930 876 1008 957 902 1036 984 928133 133 133 137 137 137 140 140 140 144 144 144 148 148 148 152 152 15244,1 44,1 44,1 46,7 46,7 46,7 49,3 49,3 49,3 51,9 51,9 51,9 54,6 54,6 54,6 57,4 57,4 57,4

1082 1053 1024 1111 1080 1050 1139 1108 1077 1168 1136 1104 1197 1164 1130 1226 1191 1157

198 217 239 199 218 240 200 218 241 200 242219 201 220 243 202 221 243

187 183 178 192 187 183 197 192 187 202 197 192 207 202 196 212 207 20187,8 83,4 79,1 92,5 87,8 83,3 97,4 92,4 87,5 102 97,1 91,9 107 102 96,4 113 107 101

321835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

947 898 845 976 926 872 1005 954 899 1034 982 926 1064 1010 953 1093 1039 980138 138 138 142 142 142 146 146 146 150 150 150 154 154 154 158 158 15847,9 47,9 47,9 50,6 50,6 50,6 53,4 53,4 53,4 56,2 56,2 56,2 59,1 59,1 59,1 62,1 62,1 62,1

1143 1112 1081 1173 1141 1109 1203 1170 1137 1233 1199 1165 1263 1228 1193 1293 1257 1221209 228 251 210 229 252 211 230 253 211 254231 212 231 255 213 232 256

198 193 188 203 198 193 208 203 198 214 208 202 219 213 207 224 218 21298,0 93,0 88,3 103 97,9 92,9 109 103 97,6 114 108 102 120 113 107 125 119 112

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

38ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 42: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS - R

RECOVERY CAPACITY PERFORMANCE

131435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

397 376 353 409 388 365 422 400 376 435 412 388 447 424 400 460 436 41161,9 61,9 61,9 63,8 63,8 63,8 65,6 65,6 65,6 67,5 67,5 67,5 69,4 69,4 69,4 71,2 71,2 71,255,6 55,6 55,6 59,0 59,0 59,0 62,5 62,5 62,5 66,1 66,1 66,1 69,8 69,8 69,8 73,6 73,6 73,6

479 466 454 492 479 466 505 492 478 518 504 490 532 517 502 545 530 514

87,8 96,7 107 88,3 97,2 107 88,8 97,7 108 89,2 10898,1 89,7 98,6 109 90,1 99,0 109

83,0 80,9 78,8 85,3 83,1 80,9 87,5 85,3 83,0 89,8 87,5 85,1 92,1 89,7 87,2 94,4 91,9 89,399,8 95,0 90,1 105 100 94,9 111 105 99,9 117 111 105 123 117 110 129 122 116

141435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

423 401 378 436 414 390 450 427 402 463 440 414 477 452 427 490 465 43965,4 65,4 65,4 67,4 67,4 67,4 69,3 69,3 69,3 71,3 71,3 71,3 73,2 73,2 73,2 75,2 75,2 75,244,1 44,1 44,1 46,8 46,8 46,8 49,5 49,5 49,5 52,3 52,3 52,3 55,3 55,3 55,3 58,2 58,2 58,2

510 497 483 524 510 496 538 523 508 552 536 521 565 550 534 579 563 54792,8 102 112 93,2 102 113 93,7 103 113 94,1 114103 94,4 104 114 94,8 104 115

88,4 86,2 83,9 90,8 88,5 86,2 93,1 90,8 88,4 95,5 93,1 90,6 97,9 95,4 92,8 100 97,7 95,080,4 76,5 72,6 84,8 80,6 76,4 89,4 84,9 80,4 94,0 89,2 84,5 98,8 93,7 88,7 104 98,3 93,0

161435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

473 448 422 487 462 436 502 476 449 517 490 462 531 505 476 546 519 49073,4 73,4 73,4 75,5 75,5 75,5 77,6 77,6 77,6 79,7 79,7 79,7 81,8 81,8 81,8 83,9 83,9 83,955,4 55,4 55,4 58,7 58,7 58,7 62,0 62,0 62,0 65,5 65,5 65,5 69,0 69,0 69,0 72,6 72,6 72,6

571 556 540 586 570 554 601 585 568 616 599 582 631 614 596 646 628 610105 114 126 105 115 126 106 115 127 106 127116 106 116 128 107 116 128

99,0 96,4 93,9 102 98,9 96,3 104 101 98,8 107 104 101 109 106 104 112 109 106101 95,8 90,9 106 101 95,6 112 106 100 117 111 105 123 117 111 129 122 116

171535 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

514 487 458 531 503 473 547 519 488 563 534 503 580 550 518 596 566 53380,4 80,4 80,4 82,8 82,8 82,8 85,2 85,2 85,2 87,6 87,6 87,6 90,0 90,0 90,0 92,4 92,4 92,440,7 40,7 40,7 43,2 43,2 43,2 45,7 45,7 45,7 48,4 48,4 48,4 51,0 51,0 51,0 53,8 53,8 53,8

622 605 588 638 621 604 655 638 619 672 654 635 689 670 651 706 686 666

114 125 138 115 126 139 115 127 140 116 140127 116 128 141 117 128 141

108 105 102 111 108 105 114 111 108 116 113 110 119 116 113 122 119 11673,0 69,4 65,9 77,0 73,2 69,4 81,2 77,1 73,0 85,4 81,0 76,7 89,8 85,1 80,5 94,2 89,3 84,4

181635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

558 529 498 576 546 514 595 564 531 613 581 547 631 599 564 650 616 58186,5 86,5 86,5 89,1 89,1 89,1 91,7 91,7 91,7 94,4 94,4 94,4 97,0 97,0 97,0 99,6 99,6 99,647,1 47,1 47,1 50,0 50,0 50,0 53,0 53,0 53,0 56,1 56,1 56,1 59,3 59,3 59,3 62,5 62,5 62,5

673 655 638 692 673 655 710 692 672 729 710 689 748 728 707 767 746 724122 135 149 122 135 150 123 136 150 124 151137 124 137 151 125 138 152

117 114 111 120 117 114 123 120 117 126 123 120 130 126 123 133 129 12685,6 81,5 77,3 90,4 86,0 81,6 95,4 90,7 85,9 101 95,5 90,4 106 100 95,0 111 105 99,7

201535 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

592 561 528 610 578 545 628 596 561 647 614 578 665 631 595 683 649 61291,9 91,9 91,9 94,5 94,5 94,5 97,2 97,2 97,2 99,9 99,9 99,9 103 103 103 105 105 10540,5 40,5 40,5 42,9 42,9 42,9 45,4 45,4 45,4 47,9 47,9 47,9 50,4 50,4 50,4 53,1 53,1 53,1

715 695 676 734 714 694 753 732 711 771 750 729 790 768 746 809 786 763131 143 158 132 144 158 132 144 159 133 160145 133 146 160 134 146 161

124 121 118 127 124 121 130 127 124 134 130 127 137 133 130 140 136 13373,6 69,9 66,3 77,5 73,6 69,7 81,6 77,4 73,3 85,7 81,2 76,9 89,9 85,2 80,7 94,2 89,3 84,5

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

39ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 43: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS - R

RECOVERY CAPACITY PERFORMANCE

211635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

635 602 567 655 621 585 675 641 603 696 660 622 716 679 640 736 699 65998,9 98,9 98,9 102 102 102 105 105 105 108 108 108 111 111 111 114 114 11446,9 46,9 46,9 49,8 49,8 49,8 52,7 52,7 52,7 55,6 55,6 55,6 58,7 58,7 58,7 61,9 61,9 61,9

766 746 725 787 766 744 808 786 764 829 806 783 849 826 802 870 846 821

140 153 169 140 154 170 141 155 170 142 171155 142 156 172 143 156 172

133 129 126 136 133 129 140 136 133 144 140 136 147 143 139 151 147 14384,6 80,4 76,3 89,2 84,7 80,3 94,0 89,2 84,5 98,9 93,8 88,8 104 98,5 93,2 109 103 97,7

231635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

683 647 609 704 667 628 725 688 648 746 708 667 768 728 687 789 749 706106 106 106 109 109 109 112 112 112 115 115 115 118 118 118 121 121 12145,9 45,9 45,9 48,6 48,6 48,6 51,4 51,4 51,4 54,3 54,3 54,3 57,3 57,3 57,3 60,3 60,3 60,3

825 803 781 847 824 801 869 845 821 891 866 842 913 887 862 935 908 882152 166 183 153 167 184 153 168 185 154 186168 155 169 186 155 170 187

143 139 136 147 143 139 151 147 143 154 150 146 158 154 150 162 158 15383,8 79,6 75,5 88,3 83,8 79,5 92,9 88,2 83,5 97,7 92,6 87,7 103 97,2 92,0 107 102 96,3

241635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

710 674 634 732 695 655 754 716 675 776 737 695 798 758 715 820 779 736110 110 110 113 113 113 116 116 116 120 120 120 123 123 123 126 126 12649,6 49,6 49,6 52,5 52,5 52,5 55,5 55,5 55,5 58,6 58,6 58,6 61,7 61,7 61,7 64,9 64,9 64,9

857 834 811 880 856 832 902 878 853 925 899 874 947 921 895 970 943 916157 171 188 157 172 189 158 172 190 158 190173 159 173 191 159 174 192

148 145 141 152 148 145 156 152 148 160 156 152 164 160 155 168 164 15990,4 85,8 81,5 95,2 90,4 85,7 100 95,0 90,1 105 99,8 94,5 110 105 99,1 116 110 104

241835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

745 706 664 769 729 686 793 752 708 818 775 730 842 799 753 867 822 775117 117 117 121 121 121 124 124 124 128 128 128 132 132 132 135 135 13550,8 50,8 50,8 54,0 54,0 54,0 57,2 57,2 57,2 60,6 60,6 60,6 64,0 64,0 64,0 67,6 67,6 67,6

898 875 851 923 899 874 948 923 897 973 947 920 998 971 943 1024 995 966

163 180 199 164 181 200 164 181 201 165 201182 166 183 202 167 184 203

156 152 148 160 156 152 164 160 156 169 164 160 173 168 164 177 173 16889,5 85,2 80,9 94,5 89,9 85,3 99,8 94,8 89,8 105 99,8 94,5 111 105 99,3 116 110 104

261835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

795 753 708 820 777 732 845 802 755 871 826 778 897 851 802 922 875 825124 124 124 127 127 127 131 131 131 135 135 135 139 139 139 142 142 14256,6 56,6 56,6 60,0 60,0 60,0 63,6 63,6 63,6 67,3 67,3 67,3 71,1 71,1 71,1 74,9 74,9 74,9

959 933 908 985 959 932 1011 984 956 1038 1009 980 1064 1035 1005 1090 1060 1029175 192 212 175 193 213 176 194 214 177 215195 178 196 216 179 196 217

166 162 158 171 166 162 175 171 166 180 175 170 184 179 175 189 184 179102 97,0 92,1 108 102 97,0 114 108 102 120 113 107 126 119 113 132 125 118

281835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

847 802 755 874 828 780 900 854 804 927 880 829 954 906 854 981 932 878131 131 131 135 135 135 139 139 139 143 143 143 147 147 147 151 151 15143,0 43,0 43,0 45,6 45,6 45,6 48,3 48,3 48,3 51,1 51,1 51,1 53,9 53,9 53,9 56,8 56,8 56,8

1022 995 967 1049 1021 993 1077 1048 1018 1105 1074 1044 1132 1101 1069 1160 1128 1095186 204 225 187 205 226 188 206 227 189 228207 190 208 229 190 209 230

177 173 168 182 177 172 187 182 177 191 186 181 196 191 186 201 196 19078,3 74,4 70,6 82,6 78,4 74,4 87,0 82,6 78,2 91,5 86,8 82,2 96,2 91,2 86,3 101 95,7 90,5

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

40ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 44: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS - R

RECOVERY CAPACITY PERFORMANCE

301835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

896 849 799 924 876 825 952 903 851 980 930 876 1008 957 902 1036 984 928139 139 139 143 143 143 147 147 147 151 151 151 155 155 155 159 159 15948,2 48,2 48,2 51,1 51,1 51,1 54,1 54,1 54,1 57,1 57,1 57,1 60,2 60,2 60,2 63,4 63,4 63,4

1082 1053 1024 1111 1080 1050 1139 1108 1077 1168 1136 1104 1197 1164 1130 1226 1191 1157

198 217 239 199 218 240 200 218 241 200 242219 201 220 243 202 221 243

187 183 178 192 187 183 197 192 187 202 197 192 207 202 196 212 207 20187,8 83,4 79,1 92,5 87,8 83,3 97,4 92,4 87,5 102 97,1 91,9 107 102 96,4 113 107 101

321835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

947 898 845 976 926 872 1005 954 899 1034 982 926 1064 1010 953 1093 1039 980148 148 148 152 152 152 157 157 157 161 161 161 165 165 165 169 169 16954,8 54,8 54,8 58,0 58,0 58,0 61,3 61,3 61,3 64,7 64,7 64,7 68,2 68,2 68,2 71,7 71,7 71,7

1143 1112 1081 1173 1141 1109 1203 1170 1137 1233 1199 1165 1263 1228 1193 1293 1257 1221209 228 251 210 229 252 211 230 253 211 254231 212 231 255 213 232 256

198 193 188 203 198 193 208 203 198 214 208 202 219 213 207 224 218 21298,0 93,0 88,3 103 97,9 92,9 109 103 97,6 114 108 102 120 113 107 125 119 112

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

41ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 45: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS - R

RECOVERY CAPACITY PERFORMANCE

131435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

397 376 353 409 388 365 422 400 376 435 412 388 447 424 400 460 436 41155,9 55,9 55,9 57,4 57,4 57,4 59,0 59,0 59,0 60,5 60,5 60,5 62,0 62,0 62,0 63,5 63,5 63,545,3 45,3 45,3 47,8 47,8 47,8 50,4 50,4 50,4 53,1 53,1 53,1 55,8 55,8 55,8 58,6 58,6 58,6

479 466 454 492 479 466 505 492 478 518 504 490 532 517 502 545 530 514

87,8 96,7 107 88,3 97,2 107 88,8 97,7 108 89,2 10898,1 89,7 98,6 109 90,1 99,0 109

83,0 80,9 78,8 85,3 83,1 80,9 87,5 85,3 83,0 89,8 87,5 85,1 92,1 89,7 87,2 94,4 91,9 89,399,8 95,0 90,1 105 100 94,9 111 105 99,9 117 111 105 123 117 110 129 122 116

141435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

423 401 378 436 414 390 450 427 402 463 440 414 477 452 427 490 465 43960,0 60,0 60,0 61,7 61,7 61,7 63,3 63,3 63,3 65,0 65,0 65,0 66,6 66,6 66,6 68,2 68,2 68,237,1 37,1 37,1 39,2 39,2 39,2 41,3 41,3 41,3 43,5 43,5 43,5 45,7 45,7 45,7 47,9 47,9 47,9

510 497 483 524 510 496 538 523 508 552 536 521 565 550 534 579 563 54792,8 102 112 93,2 102 113 93,7 103 113 94,1 114103 94,4 104 114 94,8 104 115

88,4 86,2 83,9 90,8 88,5 86,2 93,1 90,8 88,4 95,5 93,1 90,6 97,9 95,4 92,8 100 97,7 95,080,4 76,5 72,6 84,8 80,6 76,4 89,4 84,9 80,4 94,0 89,2 84,5 98,8 93,7 88,7 104 98,3 93,0

161435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

473 448 422 487 462 436 502 476 449 517 490 462 531 505 476 546 519 49066,6 66,6 66,6 68,4 68,4 68,4 70,2 70,2 70,2 72,0 72,0 72,0 73,8 73,8 73,8 75,5 75,5 75,545,7 45,7 45,7 48,2 48,2 48,2 50,8 50,8 50,8 53,4 53,4 53,4 56,1 56,1 56,1 58,8 58,8 58,8

571 556 540 586 570 554 601 585 568 616 599 582 631 614 596 646 628 610105 114 126 105 115 126 106 115 127 106 127116 106 116 128 107 116 128

99,0 96,4 93,9 102 98,9 96,3 104 101 98,8 107 104 101 109 106 104 112 109 106101 95,8 90,9 106 101 95,6 112 106 100 117 111 105 123 117 111 129 122 116

171535 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

514 487 458 531 503 473 547 519 488 563 534 503 580 550 518 596 566 53372,3 72,3 72,3 74,3 74,3 74,3 76,3 76,3 76,3 78,2 78,2 78,2 80,2 80,2 80,2 82,1 82,1 82,132,9 32,9 32,9 34,8 34,8 34,8 36,6 36,6 36,6 38,6 38,6 38,6 40,5 40,5 40,5 42,5 42,5 42,5

622 605 588 638 621 604 655 638 619 672 654 635 689 670 651 706 686 666

114 125 138 115 126 139 115 127 140 116 140127 116 128 141 117 128 141

108 105 102 111 108 105 114 111 108 116 113 110 119 116 113 122 119 11673,0 69,4 65,9 77,0 73,2 69,4 81,2 77,1 73,0 85,4 81,0 76,7 89,8 85,1 80,5 94,2 89,3 84,4

181635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

558 529 498 576 546 514 595 564 531 613 581 547 631 599 564 650 616 58177,9 77,9 77,9 80,1 80,1 80,1 82,2 82,2 82,2 84,4 84,4 84,4 86,5 86,5 86,5 88,6 88,6 88,638,2 38,2 38,2 40,4 40,4 40,4 42,6 42,6 42,6 44,8 44,8 44,8 47,1 47,1 47,1 49,5 49,5 49,5

673 655 638 692 673 655 710 692 672 729 710 689 748 728 707 767 746 724122 135 149 122 135 150 123 136 150 124 151137 124 137 151 125 138 152

117 114 111 120 117 114 123 120 117 126 123 120 130 126 123 133 129 12685,6 81,5 77,3 90,4 86,0 81,6 95,4 90,7 85,9 101 95,5 90,4 106 100 95,0 111 105 99,7

201535 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

592 561 528 610 578 545 628 596 561 647 614 578 665 631 595 683 649 61283,4 83,4 83,4 85,7 85,7 85,7 87,9 87,9 87,9 90,2 90,2 90,2 92,4 92,4 92,4 94,6 94,6 94,633,4 33,4 33,4 35,2 35,2 35,2 37,1 37,1 37,1 39,0 39,0 39,0 41,0 41,0 41,0 43,0 43,0 43,0

715 695 676 734 714 694 753 732 711 771 750 729 790 768 746 809 786 763131 143 158 132 144 158 132 144 159 133 160145 133 146 160 134 146 161

124 121 118 127 124 121 130 127 124 134 130 127 137 133 130 140 136 13373,6 69,9 66,3 77,5 73,6 69,7 81,6 77,4 73,3 85,7 81,2 76,9 89,9 85,2 80,7 94,2 89,3 84,5

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

42ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 46: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS - R

RECOVERY CAPACITY PERFORMANCE

211635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

635 602 567 655 621 585 675 641 603 696 660 622 716 679 640 736 699 65989,2 89,2 89,2 91,6 91,6 91,6 94,1 94,1 94,1 96,5 96,5 96,5 98,9 98,9 98,9 101 101 10138,2 38,2 38,2 40,3 40,3 40,3 42,5 42,5 42,5 44,7 44,7 44,7 47,0 47,0 47,0 49,3 49,3 49,3

766 746 725 787 766 744 808 786 764 829 806 783 849 826 802 870 846 821

140 153 169 140 154 170 141 155 170 142 171155 142 156 172 143 156 172

133 129 126 136 133 129 140 136 133 144 140 136 147 143 139 151 147 14384,6 80,4 76,3 89,2 84,7 80,3 94,0 89,2 84,5 98,9 93,8 88,8 104 98,5 93,2 109 103 97,7

231635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

683 647 609 704 667 628 725 688 648 746 708 667 768 728 687 789 749 70697,1 97,1 97,1 99,7 99,7 99,7 102 102 102 105 105 105 108 108 108 110 110 11038,6 38,6 38,6 40,8 40,8 40,8 43,0 43,0 43,0 45,2 45,2 45,2 47,5 47,5 47,5 49,8 49,8 49,8

825 803 781 847 824 801 869 845 821 891 866 842 913 887 862 935 908 882152 166 183 153 167 184 153 168 185 154 186168 155 169 186 155 170 187

143 139 136 147 143 139 151 147 143 154 150 146 158 154 150 162 158 15383,8 79,6 75,5 88,3 83,8 79,5 92,9 88,2 83,5 97,7 92,6 87,7 103 97,2 92,0 107 102 96,3

241635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

710 674 634 732 695 655 754 716 675 776 737 695 798 758 715 820 779 73699,9 99,9 99,9 103 103 103 105 105 105 108 108 108 111 111 111 113 113 11340,9 40,9 40,9 43,1 43,1 43,1 45,4 45,4 45,4 47,8 47,8 47,8 50,2 50,2 50,2 52,6 52,6 52,6

857 834 811 880 856 832 902 878 853 925 899 874 947 921 895 970 943 916157 171 188 157 172 189 158 172 190 158 190173 159 173 191 159 174 192

148 145 141 152 148 145 156 152 148 160 156 152 164 160 155 168 164 15990,4 85,8 81,5 95,2 90,4 85,7 100 95,0 90,1 105 99,8 94,5 110 105 99,1 116 110 104

241835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

745 706 664 769 729 686 793 752 708 818 775 730 842 799 753 867 822 775103 103 103 106 106 106 109 109 109 112 112 112 115 115 115 117 117 11739,4 39,4 39,4 41,6 41,6 41,6 43,9 43,9 43,9 46,2 46,2 46,2 48,5 48,5 48,5 50,9 50,9 50,9

898 875 851 923 899 874 948 923 897 973 947 920 998 971 943 1024 995 966

163 180 199 164 181 200 164 181 201 165 201182 166 183 202 167 184 203

156 152 148 160 156 152 164 160 156 169 164 160 173 168 164 177 173 16889,5 85,2 80,9 94,5 89,9 85,3 99,8 94,8 89,8 105 99,8 94,5 111 105 99,3 116 110 104

261835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

795 753 708 820 777 732 845 802 755 871 826 778 897 851 802 922 875 825112 112 112 115 115 115 118 118 118 121 121 121 124 124 124 127 127 12746,1 46,1 46,1 48,7 48,7 48,7 51,4 51,4 51,4 54,1 54,1 54,1 56,8 56,8 56,8 59,6 59,6 59,6

959 933 908 985 959 932 1011 984 956 1038 1009 980 1064 1035 1005 1090 1060 1029175 192 212 175 193 213 176 194 214 177 215195 178 196 216 179 196 217

166 162 158 171 166 162 175 171 166 180 175 170 184 179 175 189 184 179102 97,0 92,1 108 102 97,0 114 108 102 120 113 107 126 119 113 132 125 118

281835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

847 802 755 874 828 780 900 854 804 927 880 829 954 906 854 981 932 878120 120 120 124 124 124 127 127 127 130 130 130 133 133 133 137 137 13736,1 36,1 36,1 38,2 38,2 38,2 40,2 40,2 40,2 42,4 42,4 42,4 44,5 44,5 44,5 46,7 46,7 46,7

1022 995 967 1049 1021 993 1077 1048 1018 1105 1074 1044 1132 1101 1069 1160 1128 1095186 204 225 187 205 226 188 206 227 189 228207 190 208 229 190 209 230

177 173 168 182 177 172 187 182 177 191 186 181 196 191 186 201 196 19078,3 74,4 70,6 82,6 78,4 74,4 87,0 82,6 78,2 91,5 86,8 82,2 96,2 91,2 86,3 101 95,7 90,5

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

43ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 47: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS - R

RECOVERY CAPACITY PERFORMANCE

301835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

896 849 799 924 876 825 952 903 851 980 930 876 1008 957 902 1036 984 928127 127 127 130 130 130 134 134 134 137 137 137 141 141 141 144 144 14440,3 40,3 40,3 42,6 42,6 42,6 44,8 44,8 44,8 47,2 47,2 47,2 49,6 49,6 49,6 52,0 52,0 52,0

1082 1053 1024 1111 1080 1050 1139 1108 1077 1168 1136 1104 1197 1164 1130 1226 1191 1157

198 217 239 199 218 240 200 218 241 200 242219 201 220 243 202 221 243

187 183 178 192 187 183 197 192 187 202 197 192 207 202 196 212 207 20187,8 83,4 79,1 92,5 87,8 83,3 97,4 92,4 87,5 102 97,1 91,9 107 102 96,4 113 107 101

321835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

947 898 845 976 926 872 1005 954 899 1034 982 926 1064 1010 953 1093 1039 980133 133 133 137 137 137 140 140 140 144 144 144 148 148 148 151 151 15144,3 44,3 44,3 46,8 46,8 46,8 49,3 49,3 49,3 51,8 51,8 51,8 54,4 54,4 54,4 57,0 57,0 57,0

1143 1112 1081 1173 1141 1109 1203 1170 1137 1233 1199 1165 1263 1228 1193 1293 1257 1221209 228 251 210 229 252 211 230 253 211 254231 212 231 255 213 232 256

198 193 188 203 198 193 208 203 198 214 208 202 219 213 207 224 218 21298,0 93,0 88,3 103 97,9 92,9 109 103 97,6 114 108 102 120 113 107 125 119 112

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

44ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 48: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SL-CANECS - R

RECOVERY CAPACITY PERFORMANCE

131435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

420 398 374 434 411 387 448 425 400 462 438 412 476 452 425 490 465 43861,9 61,9 61,9 63,8 63,8 63,8 65,7 65,7 65,7 67,5 67,5 67,5 69,4 69,4 69,4 71,3 71,3 71,339,5 39,5 39,5 41,9 41,9 41,9 44,4 44,4 44,4 47,0 47,0 47,0 49,6 49,6 49,6 52,3 52,3 52,3

501 486 472 515 500 485 529 514 498 544 528 511 558 542 525 573 556 538

85,7 94,2 104 86,2 94,7 104 86,6 95,1 105 87,0 10595,5 87,4 95,9 106 87,7 96,3 106

86,7 84,4 82,0 89,2 86,8 84,3 91,7 89,2 86,6 94,2 91,6 88,9 96,7 94,0 91,2 99,2 96,4 93,577,5 73,3 69,3 82,0 77,5 73,2 86,6 81,9 77,2 91,4 86,4 81,3 96,3 91,0 85,6 101 95,7 90,0

141435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

446 422 397 460 436 410 475 450 424 490 464 437 504 478 451 519 493 46465,9 65,9 65,9 67,9 67,9 67,9 69,8 69,8 69,8 71,8 71,8 71,8 73,8 73,8 73,8 75,8 75,8 75,833,9 33,9 33,9 35,9 35,9 35,9 38,1 38,1 38,1 40,2 40,2 40,2 42,5 42,5 42,5 44,8 44,8 44,8

532 517 501 547 531 515 562 546 529 577 560 543 592 574 556 607 589 57091,8 101 111 92,2 101 111 92,7 101 112 93,1 112102 93,4 102 113 93,7 103 113

92,2 89,6 87,1 94,8 92,1 89,5 97,4 94,6 91,9 100,0 97,1 94,3 103 99,7 96,7 105 102 99,166,2 62,7 59,2 70,0 66,2 62,5 73,9 69,9 65,9 77,9 73,6 69,4 82,1 77,5 72,9 86,3 81,4 76,6

161435 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

499 472 444 514 488 459 530 503 474 546 518 488 563 534 503 579 549 51873,6 73,6 73,6 75,8 75,8 75,8 77,9 77,9 77,9 80,1 80,1 80,1 82,2 82,2 82,2 84,4 84,4 84,442,3 42,3 42,3 44,8 44,8 44,8 47,4 47,4 47,4 50,0 50,0 50,0 52,7 52,7 52,7 55,5 55,5 55,5

596 578 561 612 594 576 628 610 591 645 625 606 661 641 621 678 657 636103 113 124 104 113 124 104 114 125 105 125114 105 114 126 105 115 126

103 100 97,5 106 103 100 109 106 103 112 108 105 115 111 108 117 114 11183,0 78,5 74,1 87,7 82,8 78,2 92,4 87,3 82,3 97,3 91,8 86,5 102 96,5 90,9 107 101 95,4

171535 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

545 517 486 563 534 502 581 551 519 599 568 535 617 586 552 636 603 56880,4 80,4 80,4 82,8 82,8 82,8 85,2 85,2 85,2 87,6 87,6 87,6 90,0 90,0 90,0 92,4 92,4 92,431,0 31,0 31,0 32,9 32,9 32,9 34,8 34,8 34,8 36,8 36,8 36,8 38,9 38,9 38,9 41,0 41,0 41,0

650 631 613 668 649 629 687 667 646 705 685 663 724 702 680 743 720 697

111 122 135 112 123 135 112 123 136 113 136124 113 124 137 114 125 137

113 110 106 116 113 109 119 116 112 122 119 115 125 122 118 129 125 12160,8 57,6 54,4 64,3 60,9 57,4 68,0 64,2 60,6 71,7 67,7 63,8 75,5 71,3 67,1 79,4 74,9 70,5

181635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

589 558 524 609 577 542 629 596 560 649 615 579 669 634 597 689 653 61587,1 87,1 87,1 89,8 89,8 89,8 92,5 92,5 92,5 95,1 95,1 95,1 97,8 97,8 97,8 100 100 10036,4 36,4 36,4 38,7 38,7 38,7 41,0 41,0 41,0 43,4 43,4 43,4 45,9 45,9 45,9 48,4 48,4 48,4

702 683 662 723 702 681 743 722 700 764 742 718 785 761 737 805 781 756120 133 147 121 133 147 122 134 148 122 149135 123 135 149 123 136 150

122 118 115 125 122 118 129 125 122 132 129 125 136 132 128 139 136 13171,1 67,3 63,6 75,3 71,2 67,2 79,6 75,3 71,0 84,1 79,5 74,8 88,7 83,7 78,8 93,4 88,2 82,9

201535 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

624 591 556 643 610 574 663 629 593 684 648 611 704 668 630 724 687 64892,1 92,1 92,1 94,7 94,7 94,7 97,4 97,4 97,4 100 100 100 103 103 103 105 105 10534,8 34,8 34,8 36,8 36,8 36,8 38,9 38,9 38,9 41,1 41,1 41,1 43,3 43,3 43,3 45,6 45,6 45,6

745 723 701 765 743 720 786 762 739 806 782 758 827 802 777 847 821 796129 140 154 129 141 155 130 142 156 130 156142 131 142 157 131 143 157

129 125 122 133 129 125 136 132 128 140 136 132 143 139 135 147 142 13868,2 64,5 60,9 72,0 68,0 64,2 75,9 71,7 67,6 79,9 75,4 71,1 84,0 79,3 74,7 88,3 83,2 78,4

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

45ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 49: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SL-CANECS - R

RECOVERY CAPACITY PERFORMANCE

211635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

668 633 595 690 654 615 712 675 635 734 696 655 756 717 675 778 738 69598,9 98,9 98,9 102 102 102 105 105 105 108 108 108 111 111 111 114 114 11440,1 40,1 40,1 42,5 42,5 42,5 45,0 45,0 45,0 47,6 47,6 47,6 50,2 50,2 50,2 52,9 52,9 52,9

797 774 751 820 796 772 842 818 793 865 839 813 888 861 834 910 883 855

138 151 166 138 152 167 139 152 168 140 168153 140 153 169 141 154 170

138 134 131 142 138 134 146 142 138 150 146 141 154 149 145 158 153 14978,2 74,0 69,9 82,7 78,2 73,8 87,3 82,5 77,8 92,0 86,9 81,9 96,9 91,5 86,1 102 96,2 90,5

231635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

722 685 644 746 707 666 769 729 687 792 752 708 816 774 730 840 797 751107 107 107 110 110 110 113 113 113 116 116 116 119 119 119 122 122 12242,2 42,2 42,2 44,7 44,7 44,7 47,3 47,3 47,3 49,9 49,9 49,9 52,6 52,6 52,6 55,4 55,4 55,4

862 837 812 886 860 834 910 883 856 934 906 878 958 929 900 982 952 922149 162 179 149 163 179 150 164 180 151 181164 151 165 181 152 165 182

149 145 141 153 149 145 158 153 149 162 157 153 166 161 156 170 165 16082,5 78,0 73,7 87,2 82,4 77,7 91,9 86,8 81,9 96,8 91,4 86,2 102 96,1 90,6 107 101 95,1

241635 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

PtrePat

QreDpre

747 708 667 771 731 688 795 754 710 819 777 732 843 800 755 868 824 777111 111 111 114 114 114 117 117 117 120 120 120 124 124 124 127 127 12745,5 45,5 45,5 48,1 48,1 48,1 50,9 50,9 50,9 53,7 53,7 53,7 56,6 56,6 56,6 59,5 59,5 59,5

893 867 841 917 890 864 942 914 886 967 938 909 991 961 931 1016 985 954155 169 185 156 169 186 156 170 187 157 188171 157 171 188 158 172 189

155 150 146 159 154 150 163 159 154 167 163 158 172 167 162 176 171 16688,5 83,7 79,0 93,4 88,3 83,3 98,5 93,0 87,7 104 97,9 92,3 109 103 96,9 115 108 102

241835 40 45 35 40 45 35 40 45 35 40 45 35 40 45 35 40 45Tre

Tev 6 7 8 9 10 11

PfQevDpev

Ptre

Pat

QreDpre

788 746 702 815 772 726 841 797 750 868 823 774 895 848 799 922 874 823116 116 116 120 120 120 123 123 123 127 127 127 130 130 130 134 134 13433,7 33,7 33,7 35,8 35,8 35,8 38,0 38,0 38,0 40,2 40,2 40,2 42,5 42,5 42,5 44,9 44,9 44,9

938 912 884 965 938 909 993 964 934 1020 991 960 1048 1017 985 1076 1044 1010

159 176 195 160 177 195 161 178 196 162 197179 163 179 198 164 180 199

162 158 154 167 163 158 172 167 162 177 172 167 182 176 171 186 181 17666,0 62,5 59,1 69,9 66,2 62,4 73,9 69,9 65,9 78,1 73,8 69,5 82,4 77,8 73,2 86,8 81,9 77,1

Tre (°C) - Plant (side) heat exchanger recovery output water temperatureTev (°C) - Plant (side) cooling exchanger output water temperaturePf (kW) - Cooling capacityQev (m3/h) - Plant (side) heat exchanger water flowDpev (kPa) - Plant (side) cooling exchanger pressure dropPtre (kW) - Heat recovery thermal capacityPat (kW) - Total power inputQre (m3/h) - Plant side heat exchanger recovery water flowDpre (kPa) - Plant side heating exchanger recovery pressure drop'-' - Conditions outside the operating rangeWaterflow and pressure drop on heat exchangers calculated with 5°C of delta T

46ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 50: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECS5.1 SELECTION LIMITS

47ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

Unit in non silenced modeSelection limits

NOTE: The represented operating limit refers to the standard unit's operation. Thanks to the condensation and evaporation control deviceadopted in NECS line, the units can work in each of the possible operating mode from -10°C up to 46°C outdoor air temperature.

Tout Evap [°C]

Tair

[°C

]

-10

-5

-10

-5 0 5 10 15-15

30

25

20

15

10

5

0

45

40

35

60

55

50

Tout Evap [°C]

Twat

er [°

C]

-10

-5

-10

-5 0 5 10 15-15

30

25

20

15

10

5

0

45

40

35

60

55

50

Tout Evap [°C]

Tair

[°C

]

-10

-5

-10

-5 0 5 10 15-15

30

25

20

15

10

5

0

45

40

35

60

55

50

Tout Evap [°C]

Twat

er [°

C]

-10

-5

-10

-5 0 5 10 15-15

30

25

20

15

10

5

0

45

40

35

60

55

50

NECS /B 1314 - 3218

NECS /CA 1314 - 3218

COOLING LIMITS RECOVERY LIMITS

COOLING LIMITS RECOVERY LIMITS

pspeggio
Casella di testo
Page 51: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSSELECTION LIMITS

48ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

Unit in non silenced modeSelection limits

NOTE: The represented operating limit refers to the standard unit's operation. Thanks to the condensation and evaporation control deviceadopted in NECS line, the units can work in each of the possible operating mode from -10°C up to 46°C outdoor air temperature.

Tout Evap [°C]

Tair

[°C

]

-10

-5

-10

-5 0 5 10 15-15

30

25

20

15

10

5

0

45

40

35

60

55

50

Tout Evap [°C]

Twat

er [°

C]

-10

-5

-10

-5 0 5 10 15-15

30

25

20

15

10

5

0

45

40

35

60

55

50

Tout Evap [°C]

Twat

er [°

C]

-10

-5

-10

-5 0 5 10 15-15

30

25

20

15

10

5

0

45

40

35

60

55

50

NECS /SL 1314 - 3218

NECS /SL-CA 1314 - 2418

Tout Evap [°C]

Tair

[°C

]

-10

-5

-10

-5 0 5 10 15-15

30

25

20

15

10

5

0

45

40

35

60

55

50

COOLING LIMITS RECOVERY LIMITS

COOLING LIMITS RECOVERY LIMITS

pspeggio
Casella di testo
Page 52: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSSELECTION LIMITS

5.2 ETHYLENE GLYCOL MIXTUREEthylene glycol and water mixture, used as a heat-conveying fluid, cause a variation in unit performance. For correct data, use the factors indicated in the following tabel.

0 -5 -10 -15 -20 -25 -30 -35

50%45%40%35%30%20%12%0

0,960,9640,9650,970,9740,980,9851

1,21,171,141,111,0751,041,021

1,31,271,241,221,181,111,071cdp

cQ

cPf

cdp: pressure drop correction factorcQ: flow correction factorcPf: cooling power correction factor For data concerning other kind of anti-freeze solutions (e,g, propylene glycol)

please contact our Sale Department.

Freezing point (°C)

Ethylene glycol percentage by weight

5.3 FOULING FACTORSPerformances are based on clean condition of tubes (fouling factor = 1). For different fouling values, performance should be adjusted using the correction factors shown in the following table.

FOULING FACTORS PLANT SIDE COLD HEAT EXCHANGER AUXILIARY SIDE HEAT EXCHANGER

KE[°C]

KC[°C]FK2F2FK1F1

ff(m °CW)2

1,000 1,000 0,0 1,000 1,000 0,00 1,000 1,000 0,0 1,000 1,000 0,01,80 x 10-5

1,000 1,000 0,0 0,990 1,030 1,04,40 x 10-5

0,960 0,990 0,7 0,980 1,040 1,58,80 x 10-5

0,944 0,985 1,0 0,964 1,050 2,313,20 x 10-5

0,930 0,980 1,5 0,950 1,060 3,017,20 x 10-5

ff: fouling factorsf1 - f2: potential correction factorsfk1 - fk2: compressor power input correction factors

KE: minimum condenser outlet temperature increaseKC: maximum condenser outlet temperature decrease

49ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 53: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSB/CA/SL/SL-CA

6.1 HYDRAULIC DATA

Water flow and pressure dropWater flow in the heat exchangers is given by: Q=Px0,86/Dt Q: water flow (m3/h) Dt: difference between inlet and outlet water temp. (°C) P: heat exchanger capacity (kW)

AUXILIARY SIDE HEAT EXCHANGER

Q max

m³/h

Q min

m³/hK

-

Q max

m³/h

Q min

m³/hK

SIZE

PLANT SIDE COLD HEAT EXCHANGER

C.a.

min m³Q max

m³/h

Q min

m³/hK

14,5 38,1 99,3 0,89 - - - - - -NECS /B 131410,3 40,7 96,2 0,95 - - - - - -NECS /B 141410,3 44,4 107,7 1,03 - - - - - -NECS /B 16147,8 49,2 118,2 1,37 - - - - - -NECS /B 17157,8 53,9 127,1 1,5 - - - - - -NECS /B 18164,8 56,5 137,8 1,58 - - - - - -NECS /B 20154,8 61,2 145,3 1,71 - - - - - -NECS /B 21164,1 64,9 155,4 1,81 - - - - - -NECS /B 23164,1 68,3 161,5 1,91 - - - - - -NECS /B 24163,7 71,5 186,2 2 - - - - - -NECS /B 24183,7 76,1 186,2 2,12 - - - - - -NECS /B 26182,5 81,6 204 2,28 - - - - - -NECS /B 28182,5 85,4 204 2,38 - - - - - -NECS /B 30182,5 88,9 217,3 2,48 - - - - - -NECS /B 3218

14,5 38,1 99,3 0,89 - - - - - -NECS /CA 131410,3 40,7 96,2 0,95 - - - - - -NECS /CA 141410,3 44,4 107,7 1,03 - - - - - -NECS /CA 16147,8 49,2 118,2 1,37 - - - - - -NECS /CA 17157,8 53,9 127,1 1,5 - - - - - -NECS /CA 18164,8 56,5 137,8 1,58 - - - - - -NECS /CA 20154,8 61,2 145,3 1,71 - - - - - -NECS /CA 21164,1 61,2 155,4 1,71 - - - - - -NECS /CA 23164,1 68,3 161,5 1,91 - - - - - -NECS /CA 24163,7 71,5 186,2 2 - - - - - -NECS /CA 24183,7 76,1 186,2 2,12 - - - - - -NECS /CA 26182,5 81,6 204 2,28 - - - - - -NECS /CA 28182,5 85,4 204 2,38 - - - - - -NECS /CA 30182,5 88,9 217,3 2,48 - - - - - -NECS /CA 3218

14,5 38,1 99,3 0,89 - - - - - -NECS /SL 131410,3 40,7 96,2 0,95 - - - - - -NECS /SL 141410,3 44,4 107,7 1,03 - - - - - -NECS /SL 16147,8 49,2 118,2 1,37 - - - - - -NECS /SL 17157,8 53,9 127,1 1,5 - - - - - -NECS /SL 18164,8 56,5 137,8 1,58 - - - - - -NECS /SL 20154,8 61,2 145,3 1,71 - - - - - -NECS /SL 21164,1 61,2 155,4 1,71 - - - - - -NECS /SL 23164,1 68,3 161,5 1,91 - - - - - -NECS /SL 24163,7 71,5 186,2 2 - - - - - -NECS /SL 24183,7 76,1 186,2 2,12 - - - - - -NECS /SL 26182,5 81,6 204 2,28 - - - - - -NECS /SL 28182,5 85,4 204 2,38 - - - - - -NECS /SL 30182,5 88,9 217,3 2,48 - - - - - -NECS /SL 3218

10,3 38,1 99,3 0,89 - - - - - -NECS /SL-CA 13147,8 40,7 108 0,95 - - - - - -NECS /SL-CA 14147,8 44,4 110,1 1,03 - - - - - -NECS /SL-CA 1614

Q min: minimum water flow admitted to the heat exchangerQ max: maximum water flow admitted to the heat exchangerC.a. min: minimum water content admitted in the plant, using traditional control logic

50ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 54: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSB/CA/SL/SL-CA

HYDRAULIC DATA

AUXILIARY SIDE HEAT EXCHANGER

Q max

m³/h

Q min

m³/hK

-

Q max

m³/h

Q min

m³/hK

SIZE

PLANT SIDE COLD HEAT EXCHANGER

C.a.

min m³Q max

m³/h

Q min

m³/hK

4,8 49,2 137,8 1,37 - - - - - -NECS /SL-CA 17154,8 53,9 137,8 1,5 - - - - - -NECS /SL-CA 18164,1 56,5 149,5 1,58 - - - - - -NECS /SL-CA 20154,1 61,2 149,5 1,71 - - - - - -NECS /SL-CA 21163,7 64,9 186,2 1,81 - - - - - -NECS /SL-CA 23163,7 68,3 186,2 1,91 - - - - - -NECS /SL-CA 24162,5 71,5 204 2 - - - - - -NECS /SL-CA 2418

14,5 38,1 99,3 0,89 - - - 117 - 21,6NECS /D /B 131410,3 40,7 96,2 0,95 - - - 101 - 22,7NECS /D /B 141410,3 44,4 107,7 1,03 - - - 101 - 26,1NECS /D /B 16147,8 49,2 118,2 1,37 - - - 79 - 28,1NECS /D /B 17157,8 53,9 127,1 1,5 - - - 73 - 29,9NECS /D /B 18164,8 56,5 137,8 1,58 - - - 62 - 32,2NECS /D /B 20154,8 61,2 145,3 1,71 - - - 57 - 34,1NECS /D /B 21164,1 64,9 155,4 1,81 - - - 57 - 37,6NECS /D /B 23164,1 68,3 161,5 1,91 - - - 57 - 38,1NECS /D /B 24163,7 71,5 186,2 2 - - - 44 - 40,3NECS /D /B 24183,7 76,1 186,2 2,12 - - - 33 - 43,2NECS /D /B 26182,5 81,6 204 2,28 - - - 31 - 45,4NECS /D /B 28182,5 85,4 204 2,38 - - - 31 - 49NECS /D /B 30182,5 88,9 217,3 2,48 - - - 31 - 52,1NECS /D /B 3218

14,5 38,1 99,3 0,89 - - - 117 - 21,6NECS /D /CA 131410,3 40,7 96,2 0,95 - - - 101 - 22,7NECS /D /CA 141410,3 44,4 107,7 1,03 - - - 101 - 26,1NECS /D /CA 16147,8 49,2 118,2 1,37 - - - 79 - 28,1NECS /D /CA 17157,8 53,9 127,1 1,5 - - - 73 - 29,9NECS /D /CA 18164,8 56,5 137,8 1,58 - - - 62 - 32,2NECS /D /CA 20154,8 61,2 145,3 1,71 - - - 57 - 34,1NECS /D /CA 21164,1 61,2 155,4 1,71 - - - 57 - 37,6NECS /D /CA 23164,1 68,3 161,5 1,91 - - - 57 - 38,1NECS /D /CA 24163,7 71,5 186,2 2 - - - 44 - 40,3NECS /D /CA 24183,7 76,1 186,2 2,12 - - - 33 - 43,2NECS /D /CA 26182,5 81,6 204 2,28 - - - 31 - 45,4NECS /D /CA 28182,5 85,4 204 2,38 - - - 31 - 49NECS /D /CA 30182,5 88,9 217,3 2,48 - - - 31 - 52,1NECS /D /CA 3218

14,5 38,1 99,3 0,89 - - - 117 - 21,6NECS /D /SL 131410,3 40,7 96,2 0,95 - - - 101 - 22,7NECS /D /SL 141410,3 44,4 107,7 1,03 - - - 101 - 26,1NECS /D /SL 16147,8 49,2 118,2 1,37 - - - 79 - 28,1NECS /D /SL 17157,8 53,9 127,1 1,5 - - - 73 - 29,9NECS /D /SL 18164,8 56,5 137,8 1,58 - - - 62 - 32,2NECS /D /SL 20154,8 61,2 145,3 1,71 - - - 57 - 34,1NECS /D /SL 21164,1 61,2 155,4 1,71 - - - 57 - 37,6NECS /D /SL 23164,1 68,3 161,5 1,91 - - - 57 - 38,1NECS /D /SL 24163,7 71,5 186,2 2 - - - 44 - 40,3NECS /D /SL 24183,7 76,1 186,2 2,12 - - - 33 - 43,2NECS /D /SL 26182,5 81,6 204 2,28 - - - 31 - 45,4NECS /D /SL 28182,5 85,4 204 2,38 - - - 31 - 49NECS /D /SL 30182,5 88,9 217,3 2,48 - - - 31 - 52,1NECS /D /SL 3218

10,3 38,1 99,3 0,89 - - - 117 - 21,6NECS /D /SL-CA 13147,8 40,7 108 0,95 - - - 101 - 22,7NECS /D /SL-CA 14147,8 44,4 110,1 1,03 - - - 101 - 26,1NECS /D /SL-CA 16144,8 49,2 137,8 1,37 - - - 79 - 28,1NECS /D /SL-CA 1715

Q min: minimum water flow admitted to the heat exchangerQ max: maximum water flow admitted to the heat exchangerC.a. min: minimum water content admitted in the plant, using traditional control logic

51ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 55: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSB/CA/SL/SL-CA

HYDRAULIC DATA

AUXILIARY SIDE HEAT EXCHANGER

Q max

m³/h

Q min

m³/hK

-

Q max

m³/h

Q min

m³/hK

SIZE

PLANT SIDE COLD HEAT EXCHANGER

C.a.

min m³Q max

m³/h

Q min

m³/hK

4,8 53,9 137,8 1,5 - - - 73 - 29,9NECS /D /SL-CA 18164,1 56,5 149,5 1,58 - - - 62 - 32,2NECS /D /SL-CA 20154,1 61,2 149,5 1,71 - - - 57 - 34,1NECS /D /SL-CA 21163,7 64,9 186,2 1,81 - - - 57 - 37,6NECS /D /SL-CA 23163,7 68,3 186,2 1,91 - - - 57 - 38,1NECS /D /SL-CA 24162,5 71,5 204 2 - - - 44 - 40,3NECS /D /SL-CA 2418

14,5 38,1 99,3 0,89 - - - 14,5 38,1 99,3NECS /R /B 131410,3 40,7 96,2 0,95 - - - 10,3 40,7 96,2NECS /R /B 141410,3 44,4 107,7 1,03 - - - 10,3 44,4 107,7NECS /R /B 16146,3 49,2 130,3 1,37 - - - 6,3 49,2 130,3NECS /R /B 17156,3 53,9 130,3 1,5 - - - 6,3 53,9 130,3NECS /R /B 18164,8 56,5 137,8 1,58 - - - 4,8 56,5 137,8NECS /R /B 20154,8 61,2 145,3 1,71 - - - 4,8 61,2 145,3NECS /R /B 21164,1 64,9 155,4 1,81 - - - 4,1 64,9 155,4NECS /R /B 23164,1 68,3 161,5 1,91 - - - 4,1 68,3 161,5NECS /R /B 24163,7 71,5 186,2 2 - - - 3,7 71,5 186,2NECS /R /B 24183,7 76,1 186,2 2,12 - - - 3,7 76,1 186,2NECS /R /B 26182,5 81,6 204 2,28 - - - 2,5 81,6 204NECS /R /B 28182,5 85,4 204 2,38 - - - 2,5 85,4 204NECS /R /B 30182,5 88,9 217,3 2,48 - - - 2,5 88,9 217,3NECS /R /B 3218

14,5 38,1 99,3 0,89 - - - 14,5 38,1 99,3NECS /R /CA 131410,3 40,7 96,2 0,95 - - - 10,3 40,7 96,2NECS /R /CA 141410,3 44,4 107,7 1,03 - - - 10,3 44,4 107,7NECS /R /CA 16146,3 49,2 130,3 1,37 - - - 6,3 49,2 130,3NECS /R /CA 17156,3 53,9 130,3 1,5 - - - 6,3 53,9 130,3NECS /R /CA 18164,8 56,5 137,8 1,58 - - - 4,8 56,5 137,8NECS /R /CA 20154,8 61,2 145,3 1,71 - - - 4,8 61,2 145,3NECS /R /CA 21164,1 61,2 155,4 1,71 - - - 4,1 64,9 155,4NECS /R /CA 23164,1 68,3 161,5 1,91 - - - 4,1 68,3 161,5NECS /R /CA 24163,7 71,5 186,2 2 - - - 3,7 71,5 186,2NECS /R /CA 24183,7 76,1 186,2 2,12 - - - 3,7 76,1 186,2NECS /R /CA 26182,5 81,6 204 2,28 - - - 2,5 81,6 204NECS /R /CA 28182,5 85,4 204 2,38 - - - 2,5 85,4 204NECS /R /CA 30182,5 88,9 217,3 2,48 - - - 2,5 88,9 217,3NECS /R /CA 3218

14,5 38,1 99,3 0,89 - - - 14,5 38,1 99,3NECS /R /SL 131410,3 40,7 96,2 0,95 - - - 10,3 40,7 96,2NECS /R /SL 141410,3 44,4 107,7 1,03 - - - 10,3 44,4 107,7NECS /R /SL 16146,3 49,2 130,3 1,37 - - - 6,3 49,2 130,3NECS /R /SL 17156,3 53,9 130,3 1,5 - - - 6,3 53,9 130,3NECS /R /SL 18164,8 56,5 137,8 1,58 - - - 4,8 56,5 137,8NECS /R /SL 20154,8 61,2 145,3 1,71 - - - 4,8 61,2 145,3NECS /R /SL 21164,1 61,2 155,4 1,71 - - - 4,1 64,9 155,4NECS /R /SL 23164,1 68,3 161,5 1,91 - - - 4,1 68,3 161,5NECS /R /SL 24163,7 71,5 186,2 2 - - - 3,7 71,5 186,2NECS /R /SL 24183,7 76,1 186,2 2,12 - - - 3,7 76,1 186,2NECS /R /SL 26182,5 81,6 204 2,28 - - - 2,5 81,6 204NECS /R /SL 28182,5 85,4 204 2,38 - - - 2,5 85,4 204NECS /R /SL 30182,5 88,9 217,3 2,48 - - - 2,5 88,9 217,3NECS /R /SL 3218

10,3 38,1 99,3 0,89 - - - 10,3 38,1 99,3NECS /R /SL-CA 13147,8 40,7 108 0,95 - - - 7,8 40,7 108NECS /R /SL-CA 14147,8 44,4 110,1 1,03 - - - 7,8 44,4 110,1NECS /R /SL-CA 16144,8 49,2 137,8 1,37 - - - 4,8 49,2 137,8NECS /R /SL-CA 17154,8 53,9 137,8 1,5 - - - 4,8 53,9 137,8NECS /R /SL-CA 1816

Q min: minimum water flow admitted to the heat exchangerQ max: maximum water flow admitted to the heat exchangerC.a. min: minimum water content admitted in the plant, using traditional control logic

52ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 56: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSB/CA/SL/SL-CA

HYDRAULIC DATA

AUXILIARY SIDE HEAT EXCHANGER

Q max

m³/h

Q min

m³/hK

-

Q max

m³/h

Q min

m³/hK

SIZE

PLANT SIDE COLD HEAT EXCHANGER

C.a.

min m³Q max

m³/h

Q min

m³/hK

4,1 56,5 149,5 1,58 - - - 4,1 56,5 149,5NECS /R /SL-CA 20154,1 61,2 149,5 1,71 - - - 4,1 61,2 149,5NECS /R /SL-CA 21163,7 64,9 186,2 1,81 - - - 3,7 64,9 186,2NECS /R /SL-CA 23163,7 68,3 186,2 1,91 - - - 3,7 68,3 186,2NECS /R /SL-CA 24162,5 71,5 204 2 - - - 2,5 71,5 204NECS /R /SL-CA 2418

Q min: minimum water flow admitted to the heat exchangerQ max: maximum water flow admitted to the heat exchangerC.a. min: minimum water content admitted in the plant, using traditional control logic

53ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 57: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

7. HYDRONIC GROUPS (Optional)

The units can be supplied with a hydronic group. This houses all the main hydraulic components, thereby optimising hydraulic and electric installation space, time and cost. The innovative QuickMind control fi tted to the units in the NECS system, has been designed to work on systems with a low water content, offering highly professional alternatives to the installation of sy-stems featuring buffer units.

The integrated hydronic unit is composed of:Buffer tank (on request) -Single or twin IN-LINE centrifuge pump -differential pressure switch on the exchanger -pressure gauge -drain taps -air vent -fi lling unit -anti-freeze heater for piping -

Available pump confi gurations:Hydronic kit with one IN-LINE 2-pole low-head pump -Hydronic kit with one IN-LINE 2-pole high-head pump -Hydronic kit with IN-LINE 2-pole low-head twin pumps pump -Hydronic kit with IN-LINE 2-pole high-head twin pumps -

Inertial buffer tankThe inertial buffer tank is composed of:

700-litre buffer tank for sizes 1314/B, 1414/B, 1614/B, 1715/B, -1618/B and 2015/B (not available for 2015/B size with high head - twin in-line pump) 1000-litre storage tank for all the other sizes and versions -25 litre expansion vessel (EPDM membrane) pre-charged to -1.5 bar with a 700 litre buffer tank 40 litre expansion vessel (EPDM membrane) pre-charged to -1.5 bar with a 1000 litre buffer tank 6 bar safety valve -buffer tank with 20 mm lagging -anti-freeze heater for buffer tank available on request. -

2-pole low head pumpCentrifugal pumps with in-line suction and delivery fl anges, in single and twin versions. Pump body in cast iron and impeller in AISI 316L stainless steel or cast-iron, entirely laser technology welded. Mechanical seal with components in ceramics, carbon and EPDM elastomers. Three-phase electric motor protected to IP55, insulation class F, suitable for continuous service.

2-pole high-head pumpAll versions of the hydronic unit can be supplied with a high head pump. In these cases, the pump features a two-pole motor even in the silent-running versions.

Twin pumpA second stand-by pump for high or low pressures is availa-ble on request. The pumps are automatically exchanged on the basis of a rotation programme and the stand-by pump cuts in automatically if the primary pump fails.

GENERAL CHARACTERISTICS

Water connectionsIn the units without pumps, standard version, the connections for the water inlet and outlet both in the evaporator and in the desuperheater are inside the unit. As an accessory one can re-quest these connections fl ush with the unit.For units with pumps, the connections are always fl ush with the unit.

Water-side mechanical fi lter (optional)Y-fi lter designed and built to capture the impurities in the hy-draulic circuit. It is fi tted with a 0.9 mm stainless steel mesh car-tridge which can be replaced without removing the valve body from the piping.

Unit electrical panelThe unit electrical panel is fi tted with fuses and a circuit breaker contactor.

Special pumpsFor pumps with different confi gurations, please contact our sales department.

Additional components The supply does not include the following accessories though these are recommended to ensure correct system operation:- MA Pressure gauges upline and downline from the unit- GF Flexible joints on piping- RI On-off valves- T Outlet control thermometer

54 NECS_1314_3218_201006_GB

NECS

HFC R410A

pspeggio
Casella di testo
Page 58: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

P

S1

S2

EV/REC

SF

SC

Pd

P

DS

SF

SC

DS

DS

DS

CONFIGURATION OF HYDRONIC UNIT WITH 1/2 IN-LINE PUMPS

HYDRONIC GROUPS (Optional)

RETURN FROM HYDRAULIC SYSTEM

RETURN FROM HYDRAULIC SYSTEM

Only for NECS /D 4 C

IRC

UIT

S

3 C

IRC

UIT

S

2 C

IRC

UIT

S

DISCHARGE TO HYDRAULIC SYSTEM

DISCHARGE TO HYDRAULIC SYSTEM

The hydronic unit comprises: EV/REC Evaporator/Recovery (tube exchanger) -DS Desuperheator ( optional ) -P Water pump for only plant (side) cooling exchanger -Pd Water Differential pressure switch -SC Drain valve -SF Purge valve -S1 Exchanger water inlet probe -S2 Exchanger water outlet probe -

55 NECS_1314_3218_201006_GB HFC R410A

NECS-N

pspeggio
Casella di testo
Page 59: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CONFIGURATION OF HYDRONIC UNIT WITH 1/2 IN-LINE PUMPS AND BUFFER TANK

Pd

S1

S2

Sc1

EV/REC

~VE

Sc2VA

Sf2

AC

P P

RRMA

Sf1

Sc1

DS

SF

SC

DS

DS

DS

RETURN FROM HYDRAULIC SYSTEM

RETURN FROM HYDRAULIC SYSTEM

DISCHARGE TO HYDRAULIC SYSTEM

DISCHARGE TO HYDRAULIC SYSTEM

CIRCUITO A 2 POMPE OZIONALE

PA GROUP

Only for NECS /D

4 C

IRC

UIT

S

3 C

IRC

UIT

S

2 C

IRC

UIT

S

The hydronic unit comprises: AC Water tank -EV/REC Evaporator/Recovery (tube exchanger) -MA Water pressure gauge -P Water pump for only plant (side) cooling exchan- -ger Pd Differential pressure switch -RR Filling valve -S1 Evaporators/Condensers water inlet probe -

S2 Evaporators/Condensers water outlet probe -Sc1 Evaporator/Condenser drain valve -Sc2 Water tank drain valve -Sf1 Evaporator/Condenser breather valve -Sf2 Tank breather valve -VA Safety valve -VE Expansion tank -

HYDRONIC GROUPS (Optional)

56 NECS_1314_3218_201006_GB

NECS

HFC R410A

pspeggio
Casella di testo
Page 60: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

LOW HEAD – SINGLE IN-LINE PUMP

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pump

Hp Head of pump KP Coeffi cients for calculating pressure drops Unit with hydronic unit without network fi lterDpu Total pressure drop of hydronic groupHu Working head

PUMP SPECIFICATIONS

HYDRONIC GROUPS (Optional)

Pf (1) Q (1) Rif. Pump N. poli F.L.I. F.L.A. Hp KP KP Dpu Dpu Hu Hu

B/SL/CA SL-CA B/SL/CA SL-CA B/SL/CA SL-CA

[kW] [m3/h] [kW] [A] [kPa] [kPa] [kPa] [kPa] [kPa]

1314 354 60,9 A FCE 80-125/40 2 4,0 8,1 153,2 15,1 10,9 56,0 40,4 97 113

1414 379 65,2 A FCE 80-125/40 2 4,0 8,1 148,1 10,9 8,4 46,3 35,7 102 112

1614 413 71,0 B FCE 80-125/55 2 5,5 10,1 177,6 10,9 8,4 55,0 42,4 123 135

1715 458 78,8 B FCE 80-125/55 2 5,5 10,1 167,7 8,4 5,4 52,1 33,5 116 134

1816 501 86,2 B FCE 80-125/55 2 5,5 10,1 156,7 8,4 5,4 62,4 40,1 94 117

2015 526 90,5 C FCE 80-160/75 2 7,5 13,7 210,9 5,4 4,7 44,2 38,5 167 172

2116 569 97,9 C FCE 80-160/75 2 7,5 13,7 201,9 5,4 4,7 51,7 45,0 150 157

2316 604 103,9 E FCE4 100-250/75 4 7,5 15,3 171,0 4,7 4,3 50,7 46,4 120 125

2416 635 109,2 E FCE4 100-250/75 4 7,5 15,3 165,5 4,7 4,3 56,1 51,3 109 114

2418 665 114,4 E FCE4 100-250/75 4 7,5 15,3 159,8 4,0 2,8 52,3 36,6 107 123

2618 708 121,8 D FCE 100-160/110 2 11,0 20,0 224,7 4,0 - 59,3 - 165 -

2818 759 130,5 D FCE 100-160/110 2 11,0 20,0 215,2 2,8 - 47,7 - 167 -

3018 794 136,6 D FCE 100-160/110 2 11,0 20,0 208,2 2,8 - 52,2 - 156 -

3218 827 142,2 F FCS4 125-250/110 4 11,0 22,5 185,1 2,8 - 56,7 - 128 -

65

85

105

125

145

165

185

205

225

245

265

285

35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185 195 205 215 225

Q [m3/h]

H [

kP

a]

A

C

D

B

E

F

57 NECS_1314_3218_201006_GB HFC R410A

NECS-N

pspeggio
Casella di testo
Page 61: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

LOW HEAD - SINGLE IN-LINE PUMP WITH BUFFER TANK

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pump

Hp Head of pump KP Coeffi cients for calculating pressure drops Unit with hydronic unit without network fi lterDpu Total pressure drop of hydronic groupHu Working head

PUMP SPECIFICATIONS

Pf (1) Q (1) Rif. Pump N. poli F.L.I. F.L.A. Hp KP KP Dpu Dpu Hu Hu

B/SL/CA SL-CA B/SL/CA SL-CA B/SL/CA SL-CA

[kW] [m3/h] [kW] [A] [kPa] [kPa] [kPa] [kPa] [kPa]

1314 354 60,9 A FCE 80-125/40 2 4,0 8,1 153,2 16,0 11,8 59,3 43,7 94 110

1414 379 65,2 A FCE 80-125/40 2 4,0 8,1 148,1 11,8 9,3 50,1 39,5 98 109

1614 413 71,0 B FCE 80-125/55 2 5,5 10,1 177,6 11,8 9,3 59,5 46,9 118 131

1715 458 78,8 B FCE 80-125/55 2 5,5 10,1 167,7 9,0 6,0 55,9 37,2 112 130

1816 501 86,2 B FCE 80-125/55 2 5,5 10,1 156,7 9,0 6,0 66,8 44,6 90 112

2015 526 90,5 C FCE 80-160/75 2 7,5 13,7 210,9 6,0 5,3 49,1 43,4 162 168

2116 569 97,9 C FCE 80-160/75 2 7,5 13,7 201,9 6,0 5,3 57,5 50,8 144 151

2316 604 103,9 E FCE4 100-250/75 4 7,5 15,3 171,0 5,3 4,9 57,2 52,9 114 118

2416 635 109,2 E FCE4 100-250/75 4 7,5 15,3 165,5 5,3 4,9 63,2 58,5 102 107

2418 665 114,4 E FCE4 100-250/75 4 7,5 15,3 159,8 4,5 3,3 58,9 43,2 101 117

2618 708 121,8 D FCE 100-160/110 2 11,0 20,0 224,7 4,5 - 66,7 - 158 -

2818 759 130,5 D FCE 100-160/110 2 11,0 20,0 215,2 3,3 - 56,2 - 159 -

3018 794 136,6 D FCE 100-160/110 2 11,0 20,0 208,2 3,3 - 61,5 - 147 -

3218 827 142,2 F FCS4 125-250/110 4 11,0 22,5 185,1 3,3 - 66,8 - 118 -

65

85

105

125

145

165

185

205

225

245

265

285

35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185 195 205 215 225

Q [m3/h]

H [

kP

a]

A

C

D

B

E

F

HYDRONIC GROUPS (Optional)

58 NECS_1314_3218_201006_GB

NECS

HFC R410A

pspeggio
Casella di testo
Page 62: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

HYDRONIC GROUPS (Optional)

LOW HEAD – TWIN IN-LINE PUMP

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pump

Hp Head of pump KP Coeffi cients for calculating pressure drops Unit with hydronic unit without network fi lterDpu Total pressure drop of hydronic groupHu Working head

PUMP SPECIFICATIONS

Pf (1) Q (1) Rif. Pump N. poli F.L.I. F.L.A. Hp KP KP Dpu Dpu Hu Hu

B/SL/CA SL-CA B/SL/CA SL-CA B/SL/CA SL-CA

[kW] [m3/h] [kW] [A] [kPa] [kPa] [kPa] [kPa] [kPa]

1314 354 60,9 A FCTE 80-125/40 2 4,0 8,1 146,7 15,1 10,9 56,0 40,4 91 106

1414 379 65,2 A FCTE 80-125/40 2 4,0 8,1 140,6 10,9 8,4 46,3 35,7 94 105

1614 413 71,0 B FCTE 80-125/55 2 5,5 10,1 181,3 10,9 8,4 55,0 42,4 126 139

1715 458 78,8 B FCTE 80-125/55 2 5,5 10,1 169,2 8,4 5,4 52,1 33,5 117 136

1816 501 86,2 B FCTE 80-125/55 2 5,5 10,1 156,5 8,4 5,4 62,4 40,1 94 116

2015 526 90,5 C FCTE 80-160/75 2 7,5 13,7 202,1 5,4 4,7 44,2 38,5 158 164

2116 569 97,9 C FCTE 80-160/75 2 7,5 13,7 188,7 5,4 4,7 51,7 45,0 137 144

2316 604 103,9 D FCTE4 100-250/75 4 7,5 15,3 159,2 4,7 4,3 50,7 46,4 108 113

2416 635 109,2 D FCTE4 100-250/75 4 7,5 15,3 153,4 4,7 4,3 56,1 51,3 97 102

2418 665 114,4 D FCTE4 100-250/75 4 7,5 15,3 147,3 4,0 2,8 52,3 36,6 95 111

2618 708 121,8 E FCTE 100-160/110 2 11,0 20,0 206,7 4,0 - 59,3 - 147 -

2818 759 130,5 E FCTE 100-160/110 2 11,0 20,0 193,7 2,8 - 47,7 - 146 -

3018 794 136,6 E FCTE 100-160/110 2 11,0 20,0 184,0 2,8 - 52,2 - 132 -

3218 827 142,2 F FCTS4 125-250/110 4 11,0 22,5 183,4 2,8 - 56,7 - 127 -

85

105

125

145

165

185

205

225

245

265

285

35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185 195

Q [m3/h]

H [

kP

a]

A

C

E

B

D

F

59 NECS_1314_3218_201006_GB HFC R410A

NECS-N

pspeggio
Casella di testo
Page 63: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

LOW HEAD - TWIN IN-LINE PUMP WITH BUFFER TANK

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pump

Hp Head of pump KP Coeffi cients for calculating pressure drops Unit with hydronic unit without network fi lterDpu Total pressure drop of hydronic groupHu Working head

PUMP SPECIFICATIONS

Pf (1) Q (1) Rif. Pompa N. poli F.L.I. F.L.A. Hp KP KP Dpu Dpu Hu Hu

B/SL/CA SL-CA B/SL/CA SL-CA B/SL/CA SL-CA

[kW] [m3/h] [kW] [A] [kPa] [kPa] [kPa] [kPa] [kPa]

1314 354 60,9 A FCTE 80-125/40 2 4,0 8,1 146,7 16,0 11,8 59,3 43,7 87 103

1414 379 65,2 A FCTE 80-125/40 2 4,0 8,1 140,6 11,8 9,3 50,1 39,5 90 101

1614 413 71,0 B FCTE 80-125/55 2 5,5 10,1 181,3 11,8 9,3 59,5 46,9 122 134

1715 458 78,8 B FCTE 80-125/55 2 5,5 10,1 169,2 9,0 6,0 55,9 37,2 113 132

1816 501 86,2 B FCTE 80-125/55 2 5,5 10,1 156,5 9,0 6,0 66,8 44,6 90 112

2015 526 90,5 C FCTE 80-160/75 2 7,5 13,7 202,1 6,0 5,3 49,1 43,4 153 159

2116 569 97,9 C FCTE 80-160/75 2 7,5 13,7 188,7 6,0 5,3 57,5 50,8 131 138

2316 604 103,9 D FCTE4 100-250/75 4 7,5 15,3 159,2 5,3 4,9 57,2 52,9 102 106

2416 635 109,2 D FCTE4 100-250/75 4 7,5 15,3 153,4 5,3 4,9 63,2 58,5 90 95

2418 665 114,4 D FCTE4 100-250/75 4 7,5 15,3 147,3 4,5 3,3 58,9 43,2 88 104

2618 708 121,8 E FCTE 100-160/110 2 11,0 20,0 206,7 4,5 - 66,7 - 140 -

2818 759 130,5 E FCTE 100-160/110 2 11,0 20,0 193,7 3,3 - 56,2 - 137 -

3018 794 136,6 E FCTE 100-160/110 2 11,0 20,0 184,0 3,3 - 61,5 - 122 -

3218 827 142,2 F FCTS4 125-250/110 4 11,0 22,5 183,4 3,3 - 66,8 - 117 -

85

105

125

145

165

185

205

225

245

265

285

35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185 195

Q [m3/h]

H [

kP

a]

A

C

E

B

D

F

HYDRONIC GROUPS (Optional)

60 NECS_1314_3218_201006_GB

NECS

HFC R410A

pspeggio
Casella di testo
Page 64: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

HYDRONIC GROUPS (Optional)

HIGH HEAD - SINGLE IN-LINE PUMP

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pump

Hp Head of pump KP Coeffi cients for calculating pressure drops Unit with hydronic unit without network fi lterDpu Total pressure drop of hydronic groupHu Working head

PUMP SPECIFICATIONS

Pf (1) Q (1) Rif. Pompa N. poli F.L.I. F.L.A. Hp KP KP Dpu Dpu Hu Hu

B/SL/CA SL-CA B/SL/CA SL-CA B/SL/CA SL-CA

[kW] [m3/h] [kW] [A] [kPa] [kPa] [kPa] [kPa] [kPa]

1314 354 60,9 A FCE 80-160/75 2 7,5 13,7 240,9 15,1 10,9 56,0 40,4 185 200

1414 379 65,2 A FCE 80-160/75 2 7,5 13,7 237,1 10,9 8,4 46,3 35,7 191 201

1614 413 71,0 A FCE 80-160/75 2 7,5 13,7 231,7 10,9 8,4 55,0 42,4 177 189

1715 458 78,8 A FCE 80-160/75 2 7,5 13,7 223,9 8,4 5,4 52,1 33,5 172 190

1816 501 86,2 A FCE 80-160/75 2 7,5 13,7 215,8 8,4 5,4 62,4 40,1 153 176

2015 526 90,5 B FCE 80-200/110 2 11,0 20,0 255,9 5,4 4,7 44,2 38,5 212 217

2116 569 97,9 C FCE 100-160/110 2 11,0 20,0 247,6 5,4 4,7 51,7 45,0 196 203

2316 604 103,9 C FCE 100-160/110 2 11,0 20,0 242,3 4,7 4,3 50,7 46,4 192 196

2416 635 109,2 C FCE 100-160/110 2 11,0 20,0 237,4 4,7 4,3 56,1 51,3 181 186

2418 665 114,4 C FCE 100-160/110 2 11,0 20,0 232,3 4,0 2,8 52,3 36,6 180 196

2618 708 121,8 D FCE 100-160/185 2 18,5 32,8 333,9 4,0 - 59,3 - 275 -

2818 759 130,5 D FCE 100-160/185 2 18,5 32,8 322,8 2,8 - 47,7 - 275 -

3018 794 136,6 D FCE 100-160/185 2 18,5 32,8 314,6 2,8 - 52,2 - 262 -

3218 827 142,2 D FCE 100-160/185 2 18,5 32,8 306,9 2,8 - 56,7 - 250 -

185

205

225

245

265

285

305

325

345

365

385

405

35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185

Q [m3/h]

H [

kP

a]

AC

B

D

61 NECS_1314_3218_201006_GB HFC R410A

NECS-N

pspeggio
Casella di testo
Page 65: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

HIGH HEAD - SINGLE IN-LINE PUMP WITH BUFFER TANK

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pump

Hp Head of pump KP Coeffi cients for calculating pressure drops Unit with hydronic unit without network fi lterDpu Total pressure drop of hydronic groupHu Working head

PUMP SPECIFICATIONS

Pf (1) Q (1) Rif. Pompa N. poli F.L.I. F.L.A. Hp KP KP Dpu Dpu Hu Hu

B/SL/CA SL-CA B/SL/CA SL-CA B/SL/CA SL-CA

[kW] [m3/h] [kW] [A] [kPa] [kPa] [kPa] [kPa] [kPa]

1314 354 60,9 A FCE 80-160/75 2 7,5 13,7 240,9 16,0 11,8 59,3 43,7 182 197

1414 379 65,2 A FCE 80-160/75 2 7,5 13,7 237,1 11,8 9,3 50,1 39,5 187 198

1614 413 71,0 A FCE 80-160/75 2 7,5 13,7 231,7 11,8 9,3 59,5 46,9 172 185

1715 458 78,8 A FCE 80-160/75 2 7,5 13,7 223,9 9,0 6,0 55,9 37,2 168 187

1816 501 86,2 A FCE 80-160/75 2 7,5 13,7 215,8 9,0 6,0 66,8 44,6 149 171

2015 526 90,5 B FCE 80-200/110 2 11,0 20,0 255,9 6,0 5,3 49,1 43,4 207 213

2116 569 97,9 C FCE 100-160/110 2 11,0 20,0 247,6 6,0 5,3 57,5 50,8 190 197

2316 604 103,9 C FCE 100-160/110 2 11,0 20,0 242,3 5,3 4,9 57,2 52,9 185 189

2416 635 109,2 C FCE 100-160/110 2 11,0 20,0 237,4 5,3 4,9 63,2 58,5 174 179

2418 665 114,4 C FCE 100-160/110 2 11,0 20,0 232,3 4,5 3,3 58,9 43,2 173 189

2618 708 121,8 D FCE 100-160/185 2 18,5 32,8 333,9 4,5 - 66,7 - 267 -

2818 759 130,5 D FCE 100-160/185 2 18,5 32,8 322,8 3,3 - 56,2 - 267 -

3018 794 136,6 D FCE 100-160/185 2 18,5 32,8 314,6 3,3 - 61,5 - 253 -

3218 827 142,2 D FCE 100-160/185 2 18,5 32,8 306,9 3,3 - 66,8 - 240 -

185

205

225

245

265

285

305

325

345

365

385

405

35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185

Q [m3/h]

H [

kP

a]

AC

B

D

HYDRONIC GROUPS (Optional)

62 NECS_1314_3218_201006_GB

NECS

HFC R410A

pspeggio
Casella di testo
Page 66: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

HYDRONIC GROUPS (Optional)

HIGH HEAD - TWIN IN-LINE PUMP

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pump

Hp Head of pump KP Coeffi cients for calculating pressure drops Unit with hydronic unit without network fi lterDpu Total pressure drop of hydronic groupHu Working head

PUMP SPECIFICATIONS

Pf (1) Q (1) Rif. Pompa N. poli F.L.I. F.L.A. Hp KP KP Dpu Dpu Hu Hu

B/SL/CA SL-CA B/SL/CA SL-CA B/SL/CA SL-CA

[kW] [m3/h] [kW] [A] [kPa] [kPa] [kPa] [kPa] [kPa]

1314 354 60,9 A FCTE 80-160/75 2 7,5 13,7 242,8 15,1 10,9 56,0 40,4 187 202

1414 379 65,2 A FCTE 80-160/75 2 7,5 13,7 238,2 10,9 8,4 46,3 35,7 192 202

1614 413 71,0 A FCTE 80-160/75 2 7,5 13,7 231,3 10,9 8,4 55,0 42,4 176 189

1715 458 78,8 A FCTE 80-160/75 2 7,5 13,7 220,7 8,4 5,4 52,1 33,5 169 187

1816 501 86,2 A FCTE 80-160/75 2 7,5 13,7 209,3 8,4 5,4 62,4 40,1 147 169

2015 526 90,5 B FCTE 80-200/110 2 11,0 20,0 282,8 5,4 4,7 44,2 38,5 239 244

2116 569 97,9 C FCTE 100-160/110 2 11,0 20,0 237,3 5,4 4,7 51,7 45,0 186 192

2316 604 103,9 C FCTE 100-160/110 2 11,0 20,0 230,4 4,7 4,3 50,7 46,4 180 184

2416 635 109,2 C FCTE 100-160/110 2 11,0 20,0 223,8 4,7 4,3 56,1 51,3 168 173

2418 665 114,4 C FCTE 100-160/110 2 11,0 20,0 217,0 4,0 2,8 52,3 36,6 165 180

2618 708 121,8 D FCTE 100-160/185 2 18,5 32,8 325,3 4,0 - 59,3 - 266 -

2818 759 130,5 D FCTE 100-160/185 2 18,5 32,8 314,6 2,8 - 47,7 - 267 -

3018 794 136,6 D FCTE 100-160/185 2 18,5 32,8 306,7 2,8 - 52,2 - 254 -

3218 827 142,2 D FCTE 100-160/185 2 18,5 32,8 299,0 2,8 - 56,7 - 242 -

155

175

195

215

235

255

275

295

315

335

355

375

35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185

Q [m3/h]

H [

kP

a]

A

D

C

B

63 NECS_1314_3218_201006_GB HFC R410A

NECS-N

pspeggio
Casella di testo
Page 67: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

HIGH HEAD 2 POLES - TWIN IN-LINE PUMP WITH BUFFER TANK

(1) Values refer to rated operating conditionsPf Cooling capacity of unitQ Flow of water to evaporatorF.L.I. Power absorbed by pumpF.L.A. Current absorbed by pump

Hp Head of pump KP Coeffi cients for calculating pressure drops Unit with hydronic unit without network fi lterDpu Total pressure drop of hydronic groupHu Working head

PUMP SPECIFICATIONS

Pf (1) Q (1) Rif. Pompa N. poli F.L.I. F.L.A. Hp KP KP Dpu Dpu Hu Hu

B/SL/CA SL-CA B/SL/CA SL-CA B/SL/CA SL-CA

[kW] [m3/h] [kW] [A] [kPa] [kPa] [kPa] [kPa] [kPa]

1314 354 60,9 A FCTE 80-160/75 2 7,5 13,7 242,8 16,0 11,8 59,3 43,7 183 199

1414 379 65,2 A FCTE 80-160/75 2 7,5 13,7 238,2 11,8 9,3 50,1 39,5 188 199

1614 413 71,0 A FCTE 80-160/75 2 7,5 13,7 231,3 11,8 9,3 59,5 46,9 172 184

1715 458 78,8 A FCTE 80-160/75 2 7,5 13,7 220,7 9,0 6,0 55,9 37,2 165 183

1816 501 86,2 A FCTE 80-160/75 2 7,5 13,7 209,3 9,0 6,0 66,8 44,6 142 165

2015 526 90,5 B FCTE 80-200/110 2 11,0 20,0 282,8 6,0 5,3 49,1 43,4 234 239

2116 569 97,9 C FCTE 100-160/110 2 11,0 20,0 237,3 6,0 5,3 57,5 50,8 180 187

2316 604 103,9 C FCTE 100-160/110 2 11,0 20,0 230,4 5,3 4,9 57,2 52,9 173 177

2416 635 109,2 C FCTE 100-160/110 2 11,0 20,0 223,8 5,3 4,9 63,2 58,5 161 165

2418 665 114,4 C FCTE 100-160/110 2 11,0 20,0 217,0 4,5 3,3 58,9 43,2 158 174

2618 708 121,8 D FCTE 100-160/185 2 18,5 32,8 325,3 4,5 - 66,7 - 259 -

2818 759 130,5 D FCTE 100-160/185 2 18,5 32,8 314,6 3,3 - 56,2 - 258 -

3018 794 136,6 D FCTE 100-160/185 2 18,5 32,8 306,7 3,3 - 61,5 - 245 -

3218 827 142,2 D FCTE 100-160/185 2 18,5 32,8 299,0 3,3 - 66,8 - 232 -

155

175

195

215

235

255

275

295

315

335

355

375

35 45 55 65 75 85 95 105 115 125 135 145 155 165 175 185

Q [m3/h]

H [

kP

a]

A

D

C

B

HYDRONIC GROUPS (Optional)

64 NECS_1314_3218_201006_GB

NECS

HFC R410A

pspeggio
Casella di testo
Page 68: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS

Maximum values

8.1 ELECTRICAL DATA

CompressorSIZE

n F.L.I.[kW]

F.L.A.[A]

L.R.A.[A]

L.R.A.[A]

F.L.A.[A]

F.L.I.[kW]

F.L.A.[A]

F.L.I.[kW]

Fans (1) Total (1) (2)

1314 1 3x35,8+1x46,5 3x58,9+1x73,6 3x310+1x394 2 3.8 166 273 594

1414 1 2x35,8+2x46,5 2x58,9+2x73,6 2x310+2x394 2 3.8 177 288 608

1614 1 4x46,5 4x73,6 4x394 2 3.8 198 317 638

1715 1 3x35,8+2x46,5 3x58,9+2x73,6 3x310+2x394 2 3.8 214 351 671

1816 1 6x35,8 6x58,9 6x310 2 3.8 231 384 635

2015 1 5x46,5 5x73,6 5x394 2 3.8 249 398 719

2116 1 3x35,8+3x46,5 3x58,9+3x73,6 3x310+3x394 2 3.8 265 432 752

2316 1 1x35,8+5x46,5 1x58,9+5x73,6 1x310+5x394 2 3.8 286 461 782

2416 1 6x46,5 6x73,6 6x394 2 3.8 299 480 800

2418 1 8x35,8 8x58,9 8x310 2 3.8 310 517 768

2618 1 6x35,8+2x46,5 6x58,9+2x73,6 6x310+2x394 2 3.8 332 546 867

2818 1 4x35,8+4x46,5 4x58,9+4x73,6 4x310+4x394 2 3.8 353 576 896

3018 1 2x35,8+6x46,5 2x58,9+6x73,6 2x310+6x394 2 3.8 375 605 925

3218 1 8x46,5 8x73,6 8x394 2 3.8 396 634 955

F.L.I.: Full load powerF.L.A.: Full load currentL.R.A.: Locked rotor amperes for single compressorS.A.: Inrush current

(1) (2) Safety values to be considered when cabling the unit for power supply and line-protections(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current

Power supply: 400/3/50Voltage tolerance: 10%Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes: - climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and a maximum solar radiation of 1120 W/m2 - special climatic conditions negligible - biological conditions class 4B1 and 4C2: locations in a generic urban area - mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas - mechanical conditions class 4M1: locations protected from significant vibrations or shocks The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with diameter larger than 1 mm and rain). The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

65ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 69: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECS

Maximum values

ELECTRICAL DATA

CompressorSIZE

n F.L.I.[kW]

F.L.A.[A]

L.R.A.[A]

L.R.A.[A]

F.L.A.[A]

F.L.I.[kW]

F.L.A.[A]

F.L.I.[kW]

Fans (1) Total (1) (2)

1314 1 3x35,8+1x46,5 3x58,9+1x73,6 3x310+1x394 2 3.8 170 281 601

1414 1 2x35,8+2x46,5 2x58,9+2x73,6 2x310+2x394 2 3.8 181 295 616

1614 1 4x46,5 4x73,6 4x394 2 3.8 202 325 645

1715 1 3x35,8+2x46,5 3x58,9+2x73,6 3x310+2x394 2 3.8 218 358 679

1816 1 6x35,8 6x58,9 6x310 2 3.8 235 391 643

2015 1 5x46,5 5x73,6 5x394 2 3.8 253 406 726

2116 1 3x35,8+3x46,5 3x58,9+3x73,6 3x310+3x394 2 3.8 269 439 760

2316 1 1x35,8+5x46,5 1x58,9+5x73,6 1x310+5x394 2 3.8 292 473 793

2416 1 6x46,5 6x73,6 6x394 2 3.8 303 487 808

2418 1 8x35,8 8x58,9 8x310 2 3.8 318 532 783

2618 1 6x35,8+2x46,5 6x58,9+2x73,6 6x310+2x394 2 3.8 340 561 882

2818 1 4x35,8+4x46,5 4x58,9+4x73,6 4x310+4x394 2 3.8 361 591 911

3018 1 2x35,8+6x46,5 2x58,9+6x73,6 2x310+6x394 2 3.8 383 620 941

3218 1 8x46,5 8x73,6 8x394 2 3.8 404 650 970

F.L.I.: Full load powerF.L.A.: Full load currentL.R.A.: Locked rotor amperes for single compressorS.A.: Inrush current

(1) (2) Safety values to be considered when cabling the unit for power supply and line-protections(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current

Power supply: 400/3/50Voltage tolerance: 10%Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes: - climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and a maximum solar radiation of 1120 W/m2 - special climatic conditions negligible - biological conditions class 4B1 and 4C2: locations in a generic urban area - mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas - mechanical conditions class 4M1: locations protected from significant vibrations or shocks The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with diameter larger than 1 mm and rain). The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

66ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 70: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECS

Maximum values

ELECTRICAL DATA

CompressorSIZE

n F.L.I.[kW]

F.L.A.[A]

L.R.A.[A]

L.R.A.[A]

F.L.A.[A]

F.L.I.[kW]

F.L.A.[A]

F.L.I.[kW]

Fans (1) Total (1) (2)

1314 1 3x35,8+1x46,5 3x58,9+1x73,6 3x310+1x394 1.2 2.2 162 266 586

1414 1 2x35,8+2x46,5 2x58,9+2x73,6 2x310+2x394 1.2 2.2 174 283 603

1614 1 4x46,5 4x73,6 4x394 1.2 2.2 196 312 632

1715 1 3x35,8+2x46,5 3x58,9+2x73,6 3x310+2x394 1.2 2.2 211 344 664

1816 1 6x35,8 6x58,9 6x310 1.2 2.2 227 375 627

2015 1 5x46,5 5x73,6 5x394 1.2 2.2 245 390 710

2116 1 3x35,8+3x46,5 3x58,9+3x73,6 3x310+3x394 1.2 2.2 260 422 742

2316 1 1x35,8+5x46,5 1x58,9+5x73,6 1x310+5x394 1.2 2.2 283 453 774

2416 1 6x46,5 6x73,6 6x394 1.2 2.2 293 468 788

2418 1 8x35,8 8x58,9 8x310 1.2 2.2 301 498 749

2618 1 6x35,8+2x46,5 6x58,9+2x73,6 6x310+2x394 1.2 2.2 325 531 852

2818 1 4x35,8+4x46,5 4x58,9+4x73,6 4x310+4x394 1.2 2.2 348 565 886

3018 1 2x35,8+6x46,5 2x58,9+6x73,6 2x310+6x394 1.2 2.2 370 595 915

3218 1 8x46,5 8x73,6 8x394 1.2 2.2 391 624 944

F.L.I.: Full load powerF.L.A.: Full load currentL.R.A.: Locked rotor amperes for single compressorS.A.: Inrush current

(1) (2) Safety values to be considered when cabling the unit for power supply and line-protections(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current

Power supply: 400/3/50Voltage tolerance: 10%Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes: - climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and a maximum solar radiation of 1120 W/m2 - special climatic conditions negligible - biological conditions class 4B1 and 4C2: locations in a generic urban area - mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas - mechanical conditions class 4M1: locations protected from significant vibrations or shocks The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with diameter larger than 1 mm and rain). The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

67ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 71: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SL-CANECS

Maximum values

ELECTRICAL DATA

CompressorSIZE

n F.L.I.[kW]

F.L.A.[A]

L.R.A.[A]

L.R.A.[A]

F.L.A.[A]

F.L.I.[kW]

F.L.A.[A]

F.L.I.[kW]

Fans (1) Total (1) (2)

1314 4 3x35,8+1x46,5 3x58,9+1x73,6 3x310+1x394 1.2 2.2 165 270 591

1414 4 2x35,8+2x46,5 2x58,9+2x73,6 2x310+2x394 1.2 2.2 177 287 607

1614 4 4x46,5 4x73,6 4x394 1.2 2.2 198 316 637

1715 5 3x35,8+2x46,5 3x58,9+2x73,6 3x310+2x394 1.2 2.2 214 348 669

1816 6 6x35,8 6x58,9 6x310 1.2 2.2 229 380 631

2015 5 5x46,5 5x73,6 5x394 1.2 2.2 247 394 715

2116 6 3x35,8+3x46,5 3x58,9+3x73,6 3x310+3x394 1.2 2.2 263 426 747

2316 6 1x35,8+5x46,5 1x58,9+5x73,6 1x310+5x394 1.2 2.2 285 458 778

2416 6 6x46,5 6x73,6 6x394 1.2 2.2 296 472 793

2418 8 8x35,8 8x58,9 8x310 1.2 2.2 306 506 758

F.L.I.: Full load powerF.L.A.: Full load currentL.R.A.: Locked rotor amperes for single compressorS.A.: Inrush current

(1) (2) Safety values to be considered when cabling the unit for power supply and line-protections(1) Values calculated referring to the version with the maximum number of fans working at the max absorbed current

Power supply: 400/3/50Voltage tolerance: 10%Maximum voltage unbalance: 3%

Give the typical operating conditions of units designed for outdoor installation, which can be associated (according to reference document IEC 60721) to the following classes: - climatic conditions class 4K4H: air temperature range from -20 up to 55°C (*), relative humidity range from 4 up to 100%, with possible precipitations, at air pressure from 70 and 106 kPa and a maximum solar radiation of 1120 W/m2 - special climatic conditions negligible - biological conditions class 4B1 and 4C2: locations in a generic urban area - mechanically active substances class 4S2: locations in areas with sand or dust representative of urban areas - mechanical conditions class 4M1: locations protected from significant vibrations or shocks The required protection level for safe operation, according to reference document IEC 60529, is IP43XW (protection against access, to the most critical unit's parts, of external devices with diameter larger than 1 mm and rain). The unit can be considered IP44XW protected, i.e. protected against access of external devices (with diameter larger than 1 mm) and water in general.

(*) for the unit’s operating limits, see “selection limits” section

68ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 72: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

BNECS9.1 FULL LOAD SOUND LEVEL

SIZE Octave band [Hz]2000100050025012563 80004000

Total sound level

Sound power level dB(A)

SOUND POWER

99 98 95 93 92 87 81 76 96131499 98 95 93 92 87 81 76 96141499 98 95 93 92 87 81 76 96161499 98 95 93 92 87 81 76 961715

100 99 96 94 93 88 82 76 971816100 99 96 94 93 88 82 76 972015100 99 96 94 93 88 82 76 972116100 99 96 94 93 88 82 76 972316100 99 97 95 94 89 83 77 982416100 99 97 95 94 89 83 77 982418100 99 97 95 94 89 83 77 982618101 100 98 96 95 90 84 78 992818101 100 98 96 95 90 84 78 993018101 100 98 96 95 90 84 78 993218

Plant (side) cooling exchanger water (in/out) 12/7 °CSource (side) heat exchanger air (in) 35 °CSound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.

Working conditions

SIZE Octave band [Hz] at 10 m2000100050025012563 80004000

Total sound level

Sound pressure level dB(A)

SOUND PRESSURE LEVEL

67 66 63 61 60 55 49 44 64131467 66 63 61 60 55 49 44 64141467 66 63 61 60 55 49 44 64161467 66 63 61 60 55 49 44 64171568 67 64 62 61 56 50 44 65181668 67 64 62 61 56 50 44 65201567 66 63 61 60 55 49 43 64211667 66 63 61 60 55 49 43 64231667 66 64 62 61 56 50 44 65241667 66 64 62 61 56 50 44 65241867 66 64 62 61 56 50 44 65261868 67 65 63 62 57 51 45 66281868 67 65 63 62 57 51 45 66301868 67 65 63 62 57 51 45 663218

Plant (side) cooling exchanger water (in/out) 12/7 °CSource (side) heat exchanger air (in) 35 °CAverage sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level

Working conditions

69ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

The sound power and pressure levels of /B version, are reduced of 2 dB(A) when present the option "compressors and pumps acoustical enclosure".Additional soundproofing

pspeggio
Casella di testo
Page 73: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

CANECSFULL LOAD SOUND LEVEL

SIZE Octave band [Hz]2000100050025012563 80004000

Total sound level

Sound power level dB(A)

SOUND POWER

100 99 96 94 93 88 82 76 971314100 99 96 94 93 88 82 76 971414100 99 96 94 93 88 82 76 971614100 99 96 94 93 88 82 76 971715100 99 97 95 94 89 83 77 981816100 99 97 95 94 89 83 77 982015100 99 97 95 94 89 83 77 982116101 100 98 96 95 90 84 78 992316101 100 98 96 95 90 84 78 992416101 100 98 96 95 90 84 78 992418101 100 98 96 95 90 84 78 992618101 101 99 97 96 91 85 78 1002818101 101 99 97 96 91 85 78 1003018101 101 99 97 96 91 85 78 1003218

Plant (side) cooling exchanger water (in/out) 12/7 °CSource (side) heat exchanger air (in) 35 °CSound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.

Working conditions

SIZE Octave band [Hz] at 10 m2000100050025012563 80004000

Total sound level

Sound pressure level dB(A)

SOUND PRESSURE LEVEL

68 67 64 62 61 56 50 44 65131468 67 64 62 61 56 50 44 65141468 67 64 62 61 56 50 44 65161467 66 63 61 60 55 49 43 64171567 66 64 62 61 56 50 44 65181667 66 64 62 61 56 50 44 65201567 66 64 62 61 56 50 44 65211668 67 65 63 62 57 51 45 66231668 67 65 63 62 57 51 45 66241668 67 65 63 62 57 51 45 66241868 67 65 63 62 57 51 45 66261868 68 66 64 63 58 52 45 67281868 68 66 64 63 58 52 45 67301868 68 66 64 63 58 52 45 673218

Plant (side) cooling exchanger water (in/out) 12/7 °CSource (side) heat exchanger air (in) 35 °CAverage sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level

Working conditions

70ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

The sound power and pressure levels of /CA version, are reduced of 2 dB(A) when present the option "compressors and pumps acoustical enclosure".Additional soundproofing

pspeggio
Casella di testo
Page 74: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SLNECSFULL LOAD SOUND LEVEL

SIZE Octave band [Hz]2000100050025012563 80004000

Total sound level

Sound power level dB(A)

SOUND POWER

88 87 86 84 81 76 69 63 86131488 87 86 84 81 76 69 63 86141488 87 86 84 81 76 69 63 86161489 88 87 85 82 77 70 64 87171589 88 87 85 82 77 70 64 87181689 88 87 85 82 77 70 64 87201589 88 87 85 82 77 70 64 87211690 89 88 86 83 78 71 65 88231690 89 88 86 83 78 71 65 88241690 89 88 86 83 78 71 65 88241891 90 89 87 84 79 72 66 89261892 91 90 88 85 80 73 67 90281892 91 90 88 85 80 73 67 90301892 91 90 88 85 80 73 67 903218

Plant (side) cooling exchanger water (in/out) 12/7 °CSource (side) heat exchanger air (in) 35 °CSound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.

Working conditions

SIZE Octave band [Hz] at 10 m2000100050025012563 80004000

Total sound level

Sound pressure level dB(A)

SOUND PRESSURE LEVEL

56 55 54 52 49 44 37 31 54131456 55 54 52 49 44 37 31 54141456 55 54 52 49 44 37 31 54161456 55 54 52 49 44 37 31 54171556 55 54 52 49 44 37 31 54181656 55 54 52 49 44 37 31 54201556 55 54 52 49 44 37 31 54211657 56 55 53 50 45 38 32 55231657 56 55 53 50 45 38 32 55241657 56 55 53 50 45 38 32 55241858 57 56 54 51 46 39 33 56261859 58 57 55 52 47 40 34 57281859 58 57 55 52 47 40 34 57301859 58 57 55 52 47 40 34 573218

Plant (side) cooling exchanger water (in/out) 12/7 °CSource (side) heat exchanger air (in) 35 °CAverage sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level

Working conditions

71ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 75: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

SL-CANECSFULL LOAD SOUND LEVEL

SIZE Octave band [Hz]2000100050025012563 80004000

Total sound level

Sound power level dB(A)

SOUND POWER

88 87 86 84 81 76 69 63 86131488 87 86 84 81 76 69 63 86141488 87 86 84 81 76 69 63 86161489 88 87 85 82 77 70 64 87171589 88 87 85 82 77 70 64 87181689 88 87 85 82 77 70 64 87201589 88 87 85 82 77 70 64 87211690 89 88 86 83 78 71 65 88231690 89 88 86 83 78 71 65 88241690 89 88 86 83 78 71 65 882418

Plant (side) cooling exchanger water (in/out) 12/7 °CSource (side) heat exchanger air (in) 35 °CSound power on the basis of measurements made in compliance with ISO 9614 and Eurovent 8/1 for Eurovent certified units; in compliance with ISO 3744 for non-certified units Such certification refers specifically to the sound Power Level in dB(A). This is therefore the only acoustic data to be considered as binding.

Working conditions

SIZE Octave band [Hz] at 10 m2000100050025012563 80004000

Total sound level

Sound pressure level dB(A)

SOUND PRESSURE LEVEL

55 54 53 51 48 43 36 30 53131455 54 53 51 48 43 36 30 53141455 54 53 51 48 43 36 30 53161456 55 54 52 49 44 37 31 54171556 55 54 52 49 44 37 31 54181656 55 54 52 49 44 37 31 54201556 55 54 52 49 44 37 31 54211657 56 55 53 50 45 38 32 55231657 56 55 53 50 45 38 32 55241657 56 55 53 50 45 38 32 552418

Plant (side) cooling exchanger water (in/out) 12/7 °CSource (side) heat exchanger air (in) 35 °CAverage sound pressure level, at 10 (m.) distance, unit in a free field on a reflective surface; non-binding value obtained from the sound power level

Working conditions

72ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 76: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

"RE

MA

RK

S:

For

inst

alla

tion

purp

oses

, ple

ase

refe

r to

the

docu

men

tatio

n se

nt a

fter

the

purc

hase

-con

trac

t. T

his

tech

nica

l dat

a sh

ould

be

cons

ider

ed a

s in

dica

tive.

CLI

MA

VE

NE

TA

may

mod

ify th

em a

t any

mom

ent."

NECS9.1 DIMENSIONAL DRAWINGS

73ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 77: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSDIMENSIONAL DRAWINGS

Ø

IN/OUT

Ø

IN/OUTIN/OUTR4

[mm]

R3

[mm]

R2

[mm]

R1

[mm]

PESO

[kg]

H

[mm]

B

[mm]

A

[mm]

SIZE DIMENSIONS AND FREE SPACESPLANT SIDE COLD

HEAT EXCHANGER

ØTYPE TYPE TYPE

- AUXILIARY SIDE HEAT

EXCHANGER

3905 2260 2450 2730 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /B 1314 3905 2260 2450 2770 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /B 1414 3905 2260 2450 2800 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /B 1614 5080 2260 2450 3400 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /B 1715 5080 2260 2450 3650 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /B 1816 5080 2260 2450 3690 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /B 2015 6255 2260 2450 4200 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /B 2116 6255 2260 2450 4220 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /B 2316 6255 2260 2450 4350 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /B 2416 7430 2260 2450 5260 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /B 2418 7430 2260 2450 5300 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /B 2618 7430 2260 2450 5370 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /B 2818 7430 2260 2450 5400 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /B 3018 7430 2260 2450 5430 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /B 3218 5080 2260 2450 3060 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /CA 1314 5080 2260 2450 3100 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /CA 1414 5080 2260 2450 3130 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /CA 1614 6255 2260 2450 3800 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /CA 1715 6255 2260 2450 4050 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /CA 1816 6255 2260 2450 4090 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /CA 2015 7430 2260 2450 4540 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /CA 2116 7430 2260 2450 4630 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /CA 2316 7430 2260 2450 4690 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /CA 2416 9780 2260 2450 5930 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /CA 2418 9780 2260 2450 5970 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /CA 2618 9780 2260 2450 6040 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /CA 2818 9780 2260 2450 6070 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /CA 3018 9780 2260 2450 6110 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /CA 3218 5080 2260 2450 3060 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /SL 1314 5080 2260 2450 3160 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /SL 1414 5080 2260 2450 3200 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /SL 1614 6255 2260 2450 3900 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL 1715 6255 2260 2450 4110 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL 1816 6255 2260 2450 4190 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL 2015 7430 2260 2450 4640 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL 2116 7430 2260 2450 4730 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL 2316 7430 2260 2450 4790 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL 2416 7430 2260 2450 5410 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /SL 2418 8605 2260 2450 5810 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /SL 2618 9780 2260 2450 6160 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /SL 2818 9780 2260 2450 6200 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /SL 3018 9780 2260 2450 6250 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /SL 3218 6255 2260 2450 3490 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /SL-CA 1314 6255 2260 2450 3700 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /SL-CA 1414 6255 2260 2450 3730 1500 2300 1500 1500 VICTAULIC 4" - - - -NECS /SL-CA 1614 7430 2260 2450 4400 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL-CA 1715 7430 2260 2450 4650 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL-CA 1816 7430 2260 2450 4510 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL-CA 2015 8605 2260 2450 4990 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL-CA 2116 8605 2260 2450 5360 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL-CA 2316 8605 2260 2450 5360 1500 2300 1500 1500 VICTAULIC 5" - - - -NECS /SL-CA 2416 9780 2260 2450 6100 1500 2300 1500 1500 VICTAULIC 6" - - - -NECS /SL-CA 2418 3905 2260 2450 2730 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /B 1314 3905 2260 2450 2770 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /B 1414 3905 2260 2450 2800 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /B 1614 5080 2260 2450 3400 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /B 1715 5080 2260 2450 3650 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /B 1816 5080 2260 2450 3690 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /B 2015 6255 2260 2450 4200 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /B 2116 6255 2260 2450 4220 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /B 2316 6255 2260 2450 4350 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /B 2416 7430 2260 2450 5260 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /B 2418 7430 2260 2450 5300 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /B 2618 7430 2260 2450 5370 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /B 2818 7430 2260 2450 5400 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /B 3018 7430 2260 2450 5430 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /B 3218 5080 2260 2450 3060 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /CA 1314 5080 2260 2450 3100 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /CA 1414 5080 2260 2450 3130 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /CA 1614 6255 2260 2450 3800 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /CA 1715 6255 2260 2450 4050 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /CA 1816 6255 2260 2450 4090 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /CA 2015 7430 2260 2450 4540 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /CA 2116 7430 2260 2450 4630 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /CA 2316 7430 2260 2450 4690 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /CA 2416 9780 2260 2450 5930 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /CA 2418

74ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 78: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSDIMENSIONAL DRAWINGS

9780 2260 2450 5970 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /CA 2618 9780 2260 2450 6040 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /CA 2818 9780 2260 2450 6070 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /CA 3018 9780 2260 2450 6110 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /CA 3218 5080 2260 2450 3060 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /SL 1314 5080 2260 2450 3160 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /SL 1414 5080 2260 2450 3200 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /SL 1614 6255 2260 2450 3900 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL 1715 6255 2260 2450 4110 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL 1816 6255 2260 2450 4190 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL 2015 7430 2260 2450 4640 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL 2116 7430 2260 2450 4730 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL 2316 7430 2260 2450 4790 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL 2416 7430 2260 2450 5410 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /SL 2418 8605 2260 2450 5810 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /SL 2618 9780 2260 2450 6160 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /SL 2818 9780 2260 2450 6200 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /SL 3018 9780 2260 2450 6250 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /SL 3218 6255 2260 2450 3490 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /SL-CA 1314 6255 2260 2450 3700 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /SL-CA 1414 6255 2260 2450 3730 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 2"NECS /D /SL-CA 1614 7430 2260 2450 4400 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL-CA 1715 7430 2260 2450 4650 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL-CA 1816 7430 2260 2450 4510 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL-CA 2015 8605 2260 2450 4990 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL-CA 2116 8605 2260 2450 5360 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL-CA 2316 8605 2260 2450 5360 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 2"1/2NECS /D /SL-CA 2416 9780 2260 2450 6100 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 2"1/2NECS /D /SL-CA 2418

75ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

ØIN/OUT

ØIN/OUTIN/OUTR4

[mm]R3

[mm]R2

[mm]R1

[mm]PESO[kg]

H[mm]

B[mm]

A[mm]

SIZE DIMENSIONS AND FREE SPACESPLANT SIDE COLD HEAT EXCHANGER

ØTYPE TYPE TYPE

- AUXILIARY SIDE HEAT EXCHANGER

pspeggio
Casella di testo
Page 79: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

"RE

MA

RK

S:

For

inst

alla

tion

purp

oses

, ple

ase

refe

r to

the

docu

men

tatio

n se

nt a

fter

the

purc

hase

-con

trac

t. T

his

tech

nica

l dat

a sh

ould

be

cons

ider

ed a

s in

dica

tive.

CLI

MA

VE

NE

TA

may

mod

ify th

em a

t any

mom

ent."

NECSDIMENSIONAL DRAWINGS

76ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 80: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

NECSDIMENSIONAL DRAWINGS

Ø

IN/OUT

Ø

IN/OUTIN/OUTR4

[mm]

R3

[mm]

R2

[mm]

R1

[mm]

PESO

[kg]

H

[mm]

B

[mm]

A

[mm]

SIZE DIMENSIONS AND FREE SPACESPLANT SIDE COLD

HEAT EXCHANGER

ØTYPE TYPE TYPE

- AUXILIARY SIDE HEAT

EXCHANGER

3905 2260 2450 3130 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /B 1314 3905 2260 2450 3170 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /B 1414 3905 2260 2450 3210 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /B 1614 5080 2260 2450 4240 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /B 1715 5080 2260 2450 4500 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /B 1816 5080 2260 2450 4380 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /B 2015 6255 2260 2450 4890 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /B 2116 6255 2260 2450 4900 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /B 2316 6255 2260 2450 5030 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /B 2416 7430 2260 2450 6180 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /B 2418 7430 2260 2450 6220 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /B 2618 7430 2260 2450 6310 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /B 2818 7430 2260 2450 6350 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /B 3018 7430 2260 2450 6380 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /B 3218 5080 2260 2450 3460 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /CA 1314 5080 2260 2450 3500 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /CA 1414 5080 2260 2450 3540 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /CA 1614 6255 2260 2450 4640 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /CA 1715 6255 2260 2450 4900 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /CA 1816 6255 2260 2450 4780 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /CA 2015 7430 2260 2450 5230 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /CA 2116 7430 2260 2450 5310 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /CA 2316 7430 2260 2450 5370 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /CA 2416 9780 2260 2450 6850 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /CA 2418 9780 2260 2450 6900 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /CA 2618 9780 2260 2450 6990 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /CA 2818 9780 2260 2450 7020 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /CA 3018 9780 2260 2450 7050 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /CA 3218 5080 2260 2450 3460 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /SL 1314 5080 2260 2450 3570 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /SL 1414 5080 2260 2450 3610 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /SL 1614 6255 2260 2450 4740 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL 1715 6255 2260 2450 4950 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL 1816 6255 2260 2450 4880 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL 2015 7430 2260 2450 5330 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL 2116 7430 2260 2450 5410 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL 2316 7430 2260 2450 5470 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL 2416 7430 2260 2450 6340 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /SL 2418 8605 2260 2450 6730 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /SL 2618 9780 2260 2450 7100 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /SL 2818 9780 2260 2450 7150 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /SL 3018 9780 2260 2450 7190 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /SL 3218 6255 2260 2450 3900 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /SL-CA 1314 6255 2260 2450 4220 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /SL-CA 1414 6255 2260 2450 4260 1500 2300 1500 1500 VICTAULIC 4" - - VICTAULIC 4"NECS /R /SL-CA 1614 7430 2260 2450 5090 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL-CA 1715 7430 2260 2450 5350 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL-CA 1816 7430 2260 2450 5200 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL-CA 2015 8605 2260 2450 5680 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL-CA 2116 8605 2260 2450 6200 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL-CA 2316 8605 2260 2450 6210 1500 2300 1500 1500 VICTAULIC 5" - - VICTAULIC 5"NECS /R /SL-CA 2416 9780 2260 2450 6960 1500 2300 1500 1500 VICTAULIC 6" - - VICTAULIC 6"NECS /R /SL-CA 2418

77ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 81: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air

LEGEND OF PIPE CONNECTIONS

DIMENSIONAL DRAWINGSNECS

UNI ISO 228/1

Pipe threads where pressure-tight joints are not made on the threads - Designation, dimensions and tolerancesUsed terminology:

G: Pipe threads where pressure-tight joints are not made on the threadsA: Close tolerance class for external pipe threads where pressure-tight joints are not made on the threadsB: Wider tolerance class for external pipe threads where pressure-tight joints are not made on the threads Internal threads: G letter followed by thread mark (only tolerance class)External threads: G letter followed by thread mark and by A letter for A class external threads or by B letter for B class external threads.

UNI ISO 7/1

Pipe threads where pressure-tight joints are made on the threads - Designation, dimensions and tolerancesUsed terminology:

Rp: Internal cylindrical threads where pressure-tight joints are made on the threadsRc: Internal conical threads where pressure-tight joints are made on the threadsR: External conical threads where pressure-tight joints are made on the threadsInternal cylindrical threads: R letter followed by p letterInternal conical threads: R letter followed by c letterExternal conical threads: R letter

UNI ISO 7/1 - Rp 1 1/2

UNI ISO 7/1 - Rp 2 1/2

UNI ISO 7/1 - Rp 3

UNI ISO 228/1 - G 4 B

DN 80 PN 16

UNI ISO 7/1 - R 3

Designation Description

Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standardUNI ISO 7/1Conventional ø 1 1/2”

Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standardUNI ISO 7/1Conventional ø 2 1/2”

Internal cylindrical threads where pressure-tight joints are made on the threads, defined by standardUNI ISO 7/1Conventional ø 3”

External conical threads where pressure-tight joints are made on the threads, defined by standardUNI ISO 7/1Conventional ø 3”

Internal cylindrical threads where pressure-tight joints are not made on the threads, defined by standard UNI ISO 228/1Tolerance class B for external threadConventional ø 4”

Flange Nominal Diameter: 80 mmNominal Pressure: 16 bar

UNI ISO 7/1 UNI ISO 228/1

1"1"

2.309 mm2.309 mm

33.249 mm33.249 mm

30.291 mm30.291 mm

1.479 mm1.479 mm

Notes:

Conventional diameter value [in inches] identifies short thread designation, based upon the relative standard.All relative values are defined by standards.As example, here below some values:

Conventional ø

Pitch

External ø

Core ø

Thread height

78ELCADOC - Ver. 1.0.0.6 NECS_1314_3218_201006_EN R410A

pspeggio
Casella di testo
Page 82: 00 05 - Intro NECS 1314 3218 GB€¦ · pressure switch - air-vent valve - discharge valve - hydraulic connection fl ush with unit’s enclosure Source (side) heat exchanger air