16
Introduction CTi-mem Components User Guide CTi-mem Selection 152 155 159 163 Contents

Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Introduction

CTi-mem Components

User Guide

CTi-mem Selection

152

155

159

163

Contents

Page 2: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Customized Titanium Membrane

152

Custo

miz

ed

Tita

niu

m M

em

bra

ne

Introduction

has developed independently by Neobiotech Co., Ltd., Which is the customized

titanium membrane with minimum cutting and bending of it for attaching on the location of part used. This

product, customized titanium membrane, solved the existed rectangle membrane's own inconvenience of

cutting problem.

Go to Index

Page 3: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Customized Titanium MembraneC

usto

miz

ed

Tita

niu

m M

em

bra

ne

153

Introduction

1. Biocompatibility

Cp. Ti material has an excellent biological stability, and it is beneficial to bone formation.

2. Strong

Compare to absorbable membrane, it has a superior strength and excellent retention of BMP space.

3. Flexibility

Has an excellent flexibility due to the thinness, and it can easily produce a desired shape.

4. Customized shape

Depending on the location, it provides variety sizes of membrane that are suitable for treatment use.

Membrane with a minimum of trimming can be made into the shape you want.

5. Implant fixation

Even without the use of membrane fixing screw, it can be fixed directly to Implant.

6. Vertical Augmentation

Vertical Augmentation is adjustable with using 1mm, 1.5mm, 2mm of CTi Spacer.

7. 1-stage Surgery

After completing GBR, the CTi-Mem can be easily removed without having 2-stage surgery.

Advantage of CTi-Mem

Go to Index

Page 4: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Customized Titanium Membrane

154

Custo

miz

ed

Tita

niu

m M

em

bra

ne

Introduction

CTi-mem Characteristic

1

2

3

4

5

C

6

Lingual finger

Main function is to maintain the efficient space by covering the 2~3mm of lingual defect with easy bending. Simple

cutting if necessary.

Proximal finger

Necessary when vertical augmentation of Misial&distal defect, shape formation available with easy bending. Cut

the unnecessary part After measure the width of proximal.

Lateral augmentation part

- Put the C part as the centre and bending of a curved for 2~3mm thick side bone formation.

- Bending the side extrusion inwards in order to protect bone transplant and form the space. Porous exists to

minimize the soft tissue exposure.

Lateral cover

- Cover part of side transplant bone materials. Choose the size depends on defect length.

- Three dimensional bending available, no porous exists to be able to remove the CTi-mem with simple 2nd surgery.

Foot

Protect the transplant material as bending inwards, have membrane fixation by contacting the existing bone.

Fixing hole

The hole formed to fix the CTi-mem to fixture. Firstly connect the CTi Spacer to fixture, lift up the CTi-mem and

then fix with the CTi Healing Abutment or CTi Cover Cap. Vertical bone formation can be decided depends on CTi

Spacer height.

1

2

3

4

5

6

Go to Index

Page 5: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

CTI-mem 1

• A-Type

• B-Type

P(mm)

Proximal Width

W(mm)

Buccal Width

L(mm)

Buccal LengthCode Code

4 8 6 A1 ATMBN0810S

4 10 8 A2 ATMBN0912S

4 10 10 A3 ATMBN0915S

P(mm)

Proximal Width

W(mm)

Buccal Width

L(mm)

Buccal LengthType Code

7 9

6 B1 ATMBN0910L

8 B2 ATMBN0912L

10 B3 ATMBN0915L

10 12

6 B4 PTMBN1210S

8 B5 PTMBN1212S

10 B6 PTMBN1215S

12 12

6 B7 PTMBN1210L

8 B8 PTMBN1212L

10 B9 PTMBN1215L

• C-Type

P(mm)

Proximal Width

W(mm)

Buccal Width

L(mm)

Buccal LengthType Code

7 9

6 C1 ATMLN0910L

8 C2 ATMLN0912L

10 C3 ATMLN0915L

10 12

6 C4 PTMLN1210S

8 C5 PTMLN1212S

10 C6 PTMLN1215S

12 12

6 C7 PTMLN1210L

8 C8 PTMLN1212L

10 C9 PTMLN1215L

CTi-mem

Page 6: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

CTI mem 02

• D-Type

P(mm)

Proximal Width

W(mm)

Buccal Width

L(mm)

Buccal LengthCode Code

7 9

6 D1 ATUBN0910L

8 D2 ATUBN0912L

10 D3 ATUBN0915L

• E-Type

P(mm)

Proximal Width

L(mm)

Buccal LengthType Code

12 15 E1 CTM1215

12 20 E2 CTM1220

15 20 E3 CTM1520

• EB CTi Spacer

Type Diameter Hight(mm) Code

Narrow Ø3.5

1 ENCTS3710

1.5 ENCTS3715

2 ENCTS3720

Regular Ø4.0

1 ERCTS4010

1.5 ERCTS4015

2 ERCTS4020

Wide(3i) Ø5.0

1 EICTS5010

1.5 EICTS5015

2 EICTS5020

Wide

(Branemark)Ø5.0

1 EBCTS5010

1.5 EBCTS5015

2 EBCTS5020

• D-Type

P(mm)

Proximal Width

W(mm)

Buccal Width

L(mm)

Buccal LengthType Code

10 12

6 D4 PTUBN1210S

8 D5 PTUBN1212S

10 D6 PTUBN1215S

Hight

Diameter

CTi-mem

Page 7: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

CTI mem 03

CTi-mem

• Astra Spacer

Fixture Size Diameter Hight(mm) Code

Ø3.0

(Yellow)Ø3.5

0.5 ASCTS1405

1.0 ASCTS1410

1.5 ASCTS1415

2.0 ASCTS1420

Ø3.5 / Ø4.0

(Aqua)Ø4.0

0.5 ASCTS1605

1.0 ASCTS1610

1.5 ASCTS1615

2.0 ASCTS1620

Ø4.5 / Ø5.0

(Lilac)Ø4.0

0.5 ASCTS2005

1.0 ASCTS2010

1.5 ASCTS2015

2.0 ASCTS2020

• Zimmer Spacer

Fixture Size Diameter Hight(mm) Code

Taper Screw-Vent.

Screw-Vent

Plateform Ø3.5 Fixture

Ø3.5

0.5 ZSVCTS3505

1.0 ZSVCTS3510

1.5 ZSVCTS3515

2.0 ZSVCTS3520

Taper Screw-Vent.

Screw-Vent

Plateform

Ø3.5 / Ø4.5 Fixture

Ø4.5

0.5 ZSVCTS4505

1.0 ZSVCTS4510

1.5 ZSVCTS4515

2.0 ZSVCTS4520

Taper Screw-Vent

Plateform

Ø5.7 Fixture

Ø5.7

0.5 ZSVCTS5705

1.0 ZSVCTS5710

1.5 ZSVCTS5715

2.0 ZSVCTS5720

• IS CTi Spacer

Diameter Hight(mm) Code

Ø4.0

0.5 ISCTS4005

1 ISCTS4010

1.5 ISCTS4015

2 ISCTS4020

Hight

Diameter

Hight

Diameter

Hight

Diameter

Page 8: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

CTI mem 04

CTi-mem

• CTi Cover Cap

Diameter Hight(mm) Code

Ø4.0 1.5 CTC40

• Dentsply Spacer

Fixture Size Diameter Hight(mm) Code

Ø3.0 Fixture Ø3.0

0.5 XIVECTS3005

1.0 XIVECTS3010

1.5 XIVECTS3015

2.0 XIVECTS3020

Ø3.4 Fixture Ø3.4

0.5 XIVECTS3405

1.0 XIVECTS3410

1.5 XIVECTS3415

2.0 XIVECTS3420

Ø3.8 / Ø4.5 / Ø5.5 Fixture Ø4.5

0.5 XIVECTS4505

1.0 XIVECTS4510

1.5 XIVECTS4515

2.0 XIVECTS4520

• CTi Healing Abutment

Diameter 1(Ø) Diameter 2(Ø) Hight(mm) Code

Ø4.0

Ø4.0

3.0 CHAG404030

4.0 CHAG404040

Ø5.0

3.0 CHAG405030

4.0 CHAG405040

Hight

Hight

Diameter

Diameter 1

Diameterv2

Hight

Diameter

Page 9: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

CTI mem 05

CTi-mem

• CTi-mem Contouring plier

• CTi Cover Cap Driver

• CTi Guage

Code MCCD

Code MG00

Code MCCP

Page 10: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Customized Titanium MembraneC

usto

miz

ed

Tita

niu

m M

em

bra

ne

159

User Guide

1. Finish the implantation of the Fixture.

2. Choose CTi-Mem by using the measurement from CTi gauge and length space of bone graft.

3. Combine the membrane healing post with the fixture. By selecting the post, you need to know the

system of the implant, volume of the bone graft and EB and IS implant have two types of height(1mm,

1.5mm, 2mm) which this information can give good selection.

4. Proceed Bone graft.

5. Make model of the selected CTI- Mem. Do not bend rapidly in the same area or it will fracture the

CTI- Mem.

6. Stable the CTI-Mem and combine the membrane healing cap or membrane cover cap with below 10 Ncm.

- With the gum height use suitable healing cap.

- Use cover cap for 2nd stage surgery.

7. Suture the Soft tissue.

1. A type : 1 wall augmentation

Placement for buccal in bone defect area

Implant at the area of bone

defect

Combine CTi Spacer with

implant

Image of CTi Spacer with

implant

Bone graft at Bone defect area

Bend Cti-mem with Con-

touring plier

Bend Suitable Form by

Bending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTi

Healing abutment or CTi

Cover cap with CTi-mem

Go to Index

Page 11: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Customized Titanium Membrane

160

Custo

miz

ed

Tita

niu

m M

em

bra

ne

User Guide

2. B type : 2 wall augmentation

Placement for buccal, proximal in bone defect area

3. C type : 3 wall augmentaion

Placement for buccal, proximal and lingual in bone defect area

Implant at the area of bone

defect

Combine CTi Spacer with

implant

Image of CTi Spacer with

implant

Bone graft at Bone defect area

Bend Cti-mem with Con-

touring plier

Bend Suitable Form by

Bending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTi

Healing abutment or CTi

Cover cap with CTi-mem

Implant at the area of bone

defect

Combine CTi Spacer with

implant

Image of CTi Spacer with

implant

Bone graft at Bone defect area

Bend Cti-mem with Con-

touring plier

Bend Suitable Form by

Bending CTi-mem

Place the mount at CTi Spacer Before suture, combine CTi

Healing abutment or CTi

Cover cap with CTi-mem

Go to Index

Page 12: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Customized Titanium MembraneC

usto

miz

ed

Tita

niu

m M

em

bra

ne

161

User Guide

4. D type : 1 wall agumentation for ITI type

Placement for buccal in bone defect area

5. D type : 2 wall agumentation for ITI type

Placement for buccal and proximal in bone defect area

Detect the area of bone defect Combine cover screw or

healing abutment

Bone graft at Bone defect area Bend Cti-mem with Contouring

plier

Bend Suitable Form by Bending

CTi-mem

Before suture, place CTi -mem

at bone defect area

Detect the area of bone defect Combine cover screw or

healing abutment

Bone graft at Bone defect

area

Bend Cti-mem with Contouring

plier

Bend Suitable Form by Bending

CTi-mem

Before suture, place CTi -mem

at bone defect area

Go to Index

Page 13: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Customized Titanium Membrane

162

Custo

miz

ed

Tita

niu

m M

em

bra

ne

User Guide

6. E type : Non-fixed Submerged

Placement for large bone defect area

1. Practitioners should use after fully understand the handling and precautions of the product.

2. Since the product is supplied as sterile, CTi-mem should be used immediately after it is opened from

the package.

3. In the case of package is damaged, the condition of sterilization is likely to be damaged. Therefore, it

needs to be discarded.

4. Inadvertent exposure by a carelessness of suture can cause a redness, swelling and tissue to be

eliminated. Therefore, it needs to be removed.

5. Improper selection of patients or procedures can lead to a failure of treatment.

6. CTi-mem is a disposable single- use product. Do not reuse.

�Warning

Detect the area of bone defect Combine cover screw or

healing abutment

Bone graft at Bone defect area Bend Cti-mem with Contouring

plier

Bend Suitable Form by Bending

CTi-mem

Before suture, place CTi -mem

at bone defect area

Go to Index

Page 14: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Customized Titanium MembraneC

usto

miz

ed

Tita

niu

m M

em

bra

ne

163

CTi-mem Selection

1. Depends on the wall situation, choose A, B, C type from the CTi-men.

2. Proximal width (p) of Occlusal part that needs to be covered by Membrane is measured in oral with

determination of the 'p' size. If Proximal defect is not existed, amputate the proximal when it's 1wall

choose A, and when it's b-l defect choose C for the amputation.

3. W (Buccal Width) can be decided by P (Proximal Width) and P can be measured From B and C.

Go to Index

Page 15: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

New CTi-memNew CTi-mem provides fixing holes to give smoother access for fixing screws!

After connecting to the fixture, mount CTi-memon spacer and have statined using Cover Screw

Mount CTi-mem on a statined Tent Screw and fasten using Cover Screw

After bending or customizing, the CTi-mem,tighten the fixing screw into the foot fixing hoel

• New CTi-mem Spec

[NA3] ATMBN0915SF [NB9] PTMBN1215LF [NC9] PTMLN1215LF [NE1] CTM1215F

[NE2] CTM1220F [NE3] CTM1520F [NE4] CTM2023F [NE5] CTM25F

12mm

10mm

12mm

20mm

12mm

20mm

15mm

20mm

23mm

20mm

30mm

12mm

10mm

12mm

15mm

12mm

4mm

11mm

10mm

CTI mem 06

New CTi-mem applicationguide

Fix the Tent Screw at a defect area Choose the New CTi-mem(NE5) Tighten the Fixing Screw into each side-foot Fixing hole

Make hole Tent Screw

Tighten the Fixing Screw into the rest of Fixing holes

Bone graft Tighten the New CTi-mem with Tent Screw by using Cover Screw

Complete the New CTi-mem with bone grafting by using Tent Screw and Fixing screw

Page 16: Contentsneobiotechpt.com/assets/cti_mem_user_guide.pdf · - With the gum height use suitable healing cap. - Use cover cap for 2nd stage surgery. 7. Suture the Soft tissue. 1. A type

Ti-mesh(Neo Titanium Mesh)New Ti-mesh can be trimmed which ever form. Thickness 0.085mm / Hole size 0.8

• Type Of Ti-mesh

Size Code Code

20 x 12 T1 TMN 122008

25 x 20 T2 TMN 202508

35 x 25 T3 TMN 253508

50 x 35 T4 TMN 355008

15mm

20mm

25mm

25mm

12mm 25mm

35mm 35mm

CTI mem 07