2
Maxkold Package The Maxkold package, built with the maximum emphasis on quality, reliability and practicality at an unbeatable competitive price. Evaporator Ceiling mounted coolers Single phase Duties 1.5kw – 9.0kw R404a expansions valves pre-fitted Pre installed heat exchanges Bluefin anti-corrosion coil Powder coated light aluminium case Pre installed defrost heater 4 pole Axial fan motors Condensing Unit Components Rotary Control Panel Large display area shows all necessary information Icon LED status display Real time defrost schedule Supplied with 2 x 6 metre NTC probes 2hp compressor relay Pre wired relays Pre fitted din rail Medium / Low Temperature www.maxkold.com Sales Delivery Technical advice Parts Energy efficient Quality build Quick install Condensing Units Refrigeration Products

 · MKP-M-001 NFR075DL LFJ7.5/2.0M 1 0.75 10 ... Maxkold Limited Part of the Max Group of Companies Unit 9i Eley Estate Kynoch Road Edmonton London N18 3BD

  • Upload
    lythu

  • View
    223

  • Download
    0

Embed Size (px)

Citation preview

Page 1:  · MKP-M-001 NFR075DL LFJ7.5/2.0M 1 0.75 10 ... Maxkold Limited Part of the Max Group of Companies Unit 9i Eley Estate Kynoch Road Edmonton London N18 3BD

Maxkold Package

The Maxkold package, built with the maximum emphasis on quality, reliability and practicality at an unbeatable competitive price.

Evaporator• Ceiling mounted coolers

• Single phase

• Duties 1.5kw – 9.0kw

• R404a expansions valves pre-fi tted

• Pre installed heat exchanges

• Bluefi n anti-corrosion coil

• Powder coated light aluminium case

• Pre installed defrost heater

• 4 pole Axial fan motors

Condensing UnitComponents•

• Rotary

Control Panel• Large display area shows

all necessary information

• Icon LED status display

• Real time defrost schedule

• Supplied with 2 x 6 metre NTC probes

• 2hp compressor relay

• Pre wired relays

• Pre fi tted din rail

Medium / Low Temperature

www.maxkold.com

Sales Delivery Technical advice

Parts Energy effi cient

Qualitybuild

Quickinstall

Condensing Units • Refrigeration Products

Page 2:  · MKP-M-001 NFR075DL LFJ7.5/2.0M 1 0.75 10 ... Maxkold Limited Part of the Max Group of Companies Unit 9i Eley Estate Kynoch Road Edmonton London N18 3BD

Technical specifi cation

All products are sold within the Terms & Conditions of Maxkold Ltd. These are available on request.Maxkold Ltd has the right to make changes without prior notice.

MEDIUM - Chiller Room at +2C/-2C. Refrigerant R404A. Using Maxkold units with Maxkold Evaporators

Model Number

MaxkoldPackaged

Condensing Unit

MaxkoldCooler

No ofCoolerFans

CondensingUnit HP

Approx Room

Volume(m3)

SystemCapacity

(kW)

TEVModel

Orifi ceNo

ControllerLiquid LineSize

Suct LineSize

MaxPipe Run

MKP-M-001 NFR075DL LFJ7.5/2.0M 1 0.75 10 - 14 2.0 Danfoss TES-2 2# CM-B (3M) 3/8 1/2 15 M

MKP-M-002 NFR100DL LFJ7.5/2.0M 1 1 20 2.3 Danfoss TES-2 2# CM-B (3M) 3/8 1/2 15 M

MKP-M-003 NFR150DL LFJ11/2.8M 1 1.5 23 2.8 Danfoss TES-2 3# CM-B (3M) 3/8 1/2 15 M

MKP-M-004 NFR200DL LFJ14/3.6M 2 2 28 - 35 4.0 Danfoss TES-2 3# CM-B (3M) 3/8 5/8 15 M

MKP-M-005 NFR250DL LFJ18/4.6M 2 2.5 42 4.5 Danfoss TES-2 3# CM-B (3M) 3/8 5/8 15 M

MKP-M-006 NF200DGM LFJ14/3.6M 2 2 28 - 35 3.6 Danfoss TES-2 3# CM-B (3M) 3/8 3/4 27 M

MKP-M-007 NF200SGM LFJ14/3.6M 2 2 28 - 35 3.6 Danfoss TES-2 3# CM-B (3M) 3/8 3/4 27 M

MKP-M-008 NF250DGM LFJ18/4.6M 2 2.5 42 4.5 Danfoss TES-2 3# CM-B (3M) 3/8 3/4 27 M

MKP-M-009 NF250SGM LFJ18/4.6M 2 2.5 42 4.5 Danfoss TES-2 3# CM-B (3M) 3/8 3/4 27 M

MKP-M-010 NF300DMG LFJ20/5.4M 3 3 57 5.5 Danfoss TES-2 4# CM-B (3M) 3/8 3/4 27 M

MKP-M-011 NF300SGM LFJ20/5.4M 3 3 57 5.5 Danfoss TES-2 4# CM-B (3M) 3/8 3/4 27 M

MKP-M-012 NF350DGM LFJ26/6.8M 3 3.5 70 6.4 Danfoss TES-2 4# CM-B (3M) 1/2 3/4 27 M

MKP-M-013 NF350SGM LFJ26/6.8M 3 3.5 70 6.4 Danfoss TES-2 4# CM-B (3M) 1/2 3/4 27 M

MKP-M-014 NF400SGM LFJ28/7.8M 4 4 85 7.5 Danfoss TES-2 5# CM-B (3M) 1/2 3/4 27 M

MKP-M-015 NF500SGM LFJ35/9.0M 4 5 95 9.4 Danfoss TES-2 6# CM-B (3M) 1/2 7/8 27 M

MEDIUM = Ambient temperature room 27 c (80 c). Ambient temperature to condenser 32 c (90 c). Insulation 75mm polyurethane (sides, walls & fl oors) Product load based on 64kg/m3. Entering at no more than 4c above room temperature. Product Sp. Ht. 3.14kj/kg/k.

LOW = Ambient temperature room 27 c (80 c). Ambient temperature to condenser 32 c (90 c). Insulation 75mm polyurethane (sides, walls & fl oors) Product load based on 56kg/m3. Entering at no more than 5c above room temperature. Product Sp. Ht. 1.88kj/kg/k.

LOW - Freezer Room at -18 C. Refrigerant R404A. Using Maxkold units with Maxkold Evaporators

Model Number

MaxkoldPackaged

Condensing Unit

MaxkoldCooler

No ofCoolerFans

CondensingUnit HP

Approx Room

Volume(m3)

SystemCapacity

(kW)

TEVModel

Orifi ceNo

ControllerLiquid LineSize

Suct LineSize

MaxPipe Run

MKP-L-001 NFR075DL LFJ3.5/1.0L 1 0.75 2 0.7 Danfoss TES-2 0# CM-B (6M) 3/8 1/2 15 M

MKP-L-002 NFR100DL LFJ3.5/1.0L 1 1.0 3 0.9 Danfoss TES-2 0# CM-B (6M) 3/8 1/2 15 M

MKP-L-003 NFR150DL LFJ5.0/1.3L 1 1.5 4 1.2 Danfoss TES-2 1# CM-B (6M) 3/8 5/8 15 M

MKP-L-004 NFR200DL LFJ7.0/1.8L 1 2.0 7 1.7 Danfoss TES-2 2# CM-B (6M) 3/8 5/8 15 M

MKP-L-005 NFR250DL LFJ7.0/1.8L 1 2.5 8 1.9 Danfoss TES-2 2# CM-B (6M) 3/8 5/8 15 M

MKP-L-006 NF300DGM LFJ9.0/2.4L 1 3.0 16 2.4 Danfoss TES-2 2# CM-B (6M) 3/8 3/4 20 M

MKP-L-007 NF350DGM LFJ9.0/2.4L 2 3.5 20 2.4 Danfoss TES-2 2# CM-B (6M) 1/2 3/4 20 M

MKP-L-008 NF500SGM LFJ12/3.2L 2 5.0 28 2.8 Danfoss TES-2 3# CM-B (6M) 1/2 3/4 20 M

MKP-L-009 NF600SGM LFJ12/3.2L 2 6.0 35 3.2 Danfoss TES-2 3# CM-B (6M) 1/2 7/8 20 M

MKP-L-010 NF600SGM LFJ14/3.8L 3 6.0 42 3.5 Danfoss TES-2 3# CM-B (6M) 1/2 7/8 20 M

MKP-L-011 NF400SGL LFJ12/3.2L 2 4.0 28 2.8 Danfoss TES-2 3# CM-B (6M) 1/2 3/4 30 M

MKP-L-012 NF500SGL LFJ12/3.2L 2 5.0 35 3.2 Danfoss TES-2 3# CM-B (6M) 1/2 3/4 30 M

MKP-L-013 NF500SGL LFJ17/4.4L 3 5.0 45 4.4 Danfoss TES-2 3# CM-B (6M) 1/2 3/4 30 M

MKP-L-014 NF600SGL LFJ19/5.0L 4 6.0 60 5.0 Danfoss TES-2 3# CM-B (6M) 1/2 7/8 30 M

Maxkold Limited Part of the Max Group of Companies

Unit 9i Eley Estate Kynoch Road Edmonton London N18 3BD

Tel: +44 (0)20 8997 0476 Fax: +44 (0)20 8997 1367 Email: [email protected]