22
1. mi-ma-mo Focus on the finger-rest cont act points in the mouth y dimension: Set the camera at the mids agittal plane of a patient or a sim head. Use a stick like a sliding aerial to de cide the direction of the camera that covers the finger- rest contact points mi-ma-mo). Reference conditions for photo taking of 20 items in kb3 Set the camera to the direction of the aerial. Take the aerial away and click the shutter.

1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

Embed Size (px)

Citation preview

Page 1: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head.      ② Use a stick like a sliding aerial to decide the direction of the camera that covers the finger-rest contact points ( mi-ma-mo).

Reference conditions for photo taking of 20 items in kb3

③Set the camera to the direction of the aerial.

④Take the aerial away and click the shutter.

Page 2: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

➄ Include the end of the instrument held by the right hand in the shooting range

⑥ Make sure that the directions of the mirror surface and the handle in the left hand is clearly seen.

2.  Photo of the side view of an operator’s upper body

① z dimension - Set the camera at the height of the operator’s shoulder.

② x dimension – Set the camera parallel to the midsagittal plane of the patient.

③ z dimension – Range from the top of the head to the thigh.

④ y dimension – Range from the back of the operator to the chest of the patient.

Page 3: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te1 me explorerta00ma16 mo336682( 33=facial surface, 66=distal-lingual line angle, 82=apical point)

Page 4: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te2 me explorerta00ma36 mo365362( 36=distal surface, 53=facial aspect, 62=gingival border)

Page 5: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te3 me impression trayta03ma01 mo4162( 41=apical alveolar aspect, 62=apical border

Page 6: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te4 me impression trayta03ma02 mo4162( 41=apical alveolar aspect, 62=apical border)

Page 7: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te5 me periapical x-ray filmta06ma16 mo33( 33=facial surface, x=mesial-distal, z=occlusal-apical locations)

Page 8: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te6 me chart and aids (x-rays)ta10ma00 ( treatment plan presentation, informed consent, full body relations)

Page 9: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te7 me band pusherta37ma36 mo3365( 33=facial surface, 66=distal border)

This orthodontic band pusher will be replaced by a newly designed one.

Page 10: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te8 me root scraperta44ma17 mo19365382( 19=unwanted substance, 36=distal surface, 53=facial aspect, 82-gingival point)

Page 11: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te9 me root scraperta44ma36 mo19365462( 19=unwanted substance, 36=distal surface, 54=lingual aspect, 62=gingival border)

Page 12: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te10 me handpieceta54ma22 mo19344881(19=unwanted substance, 34=lingual surface, 48=cingulum-occlusal aspect, 81=occlusal point)

Page 13: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te11 me handpieceta57ma17 mo364864(36=distal surface, 48=middle 3rd crown, 64=lingual line)

Page 14: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te12 me handpieceta57ma46 mo364864(36=distal surface, 48=middle 3rd of crown, 64=lingual line)

Page 15: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te13 me endodontic fileta66ma16 mo05113291( 05=pulp space, 1132=root, 91=mesial-facial)

Page 16: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te14 me endodontic fileta66ma36 mo05113291( 05=pulp space, 1132=root, 91=mesial facial)

Page 17: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te15 me root tip removerta74ma14 mo0681( 06=periodontal ligament, 81=occlusal end)

Page 18: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te16 me extraction forcepsta75ma16 mo063163,64( 06=periodontal ligament, 31=occlusal, 63,64=facial and lingual lines)

Page 19: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te17 me extraction forcepsta75ma36 mo063163,64( 06=periodontal ligament, 31=occlusal, 63,64= facial and lingual lines)

Page 20: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te18 me anesthetic needleta77ma17 mo33416285( 33=facial surface, 62=alveolar border, 85=mesial point)

Page 21: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te19 me anesthetic needleta77ma30 mo86 z、x  mm ( 86=distal end, z=occlussal-apical, x=mesial-distal location (mm) from mo86 )

Note: ta77ma40 inject with left fingers at mi1±0?

Page 22: 1. mi-ma-mo ( Focus on the finger-rest contact points in the mouth ) ① y dimension: Set the camera at the midsagittal plane of a patient or a sim head

te20 me sim/clinical materialma9363ma00 mo31( 31=occlusal surface)

Note: This material is isocompound (GC company).