Introduction to Base Transceiver Station (BTS) and Its Cards
LAB # 6
Engr. Mehran Mamonai
Appearance of BTS3012 Cabinet
Like a server cabinet
The BTS3012 cabinet is purple gray in color and vertical in appearance
Physical Structure of the BTS3012
The components are
1. Transmission subrack2. Common subrack3. DTRU subrack -04. Fan subrack5. DTRU subrack-16. DAFU subrack 7. Power distribution unit 8. Signal lightning protection subrack
Transmission sub-rack
located below the common sub-rack. Reserves space for the baseband unit
(BBU).› Such as SDH,› microwave transmission equipment
Common subrack
Common subrack The common subrack is installed below the
fan subrack. It holds the following parts:› DTMU › DEMU › DATU › DCSU › DCCU › DABB › DPTU
DTMU
Dual Transmission or Timing Management Unit
an entity for basic transmission and control in the BTS3012.
It works as a main controller. The DTMU is a mandatory module
inserted in slots 0 and 1 (from left to right)
DTMU (cont.)
DEMU
Dual Environment Monitoring Unit The DEMU performs the following
functions:› Monitors the environment information sent
from the smoke sensor, water sensor, temperature and humidity sensor, infrared sensor, and door control sensor
› Collects alarm information and reports it to the DTMU
DATU
Dual Antenna and TMA Control Unit
Controls the RET antenna Feeds power to the TMA
DCSU
Combined cabinet Signal connection Unit is placed in slot 5 of the common sub-rack
The DCSU is a mandatory board The DCSU performs the following functions:
› Transmits clock signals, data signals, and control signals between the main cabinet and the extension cabinet
› Transmits the clock signals, data signals, and control signals from the DTMU to the DTRU
DCCU
Cable Connection Unit is placed in slot 6.
The DCCU is a mandatory board. The DCCU performs the following
functions:› Transfers E1 signals › Transfers the control signals for the fans › Transfers the clock signals from the DAFU
subrack
DPTU
Packet transmission unit can be installed in slot 3 or 4
The DPTU is mandatory The DPTU performs the following
functions:› Provides the interface for Abis over IP › Provides the BTS with the convergence
function of a Hub › Provides the functionality of Clock Over IP
DTRU subrack
The DTRU subracks can hold up to nine DTRUs
DTRU
Double-Transceiver Unit (DTRU) is placed in the double-transceiver subsystem of the BTS.
One DTRU consists of two TRXs Baseband Processing Part
› The baseband processing part performs the following functions:
› Processing signaling, coding and decoding, interleaving and de-interleaving, modulation and demodulation
› Supports RF loop test and switchover of the faulty phase-locked loop
› Amplifying output power
DTRU (cont.)
RF Transmitting Part› The transmitting part of the RF signals performs the
following functions:› Modulates the baseband signals into RF signals and
performs up-conversion, filtering, and RF hopping › Amplifies and outputs the RF signals
RF Receiving Part› The receiving part of the RF signals performs the
following functions:› Demodulates the RF signals into baseband signals and
performs RF hopping › Divides the received RF signals and performs receive
diversity
Fan subrack
The fan subrack holds one fan box a fan monitoring board consists of four
fans. The fan monitoring board detects the
temperature at air inlets at bottom of the cabinet and automatically adjusts the fan speed
DAFU subrack
Antenna Front-end Unit The DAFU subrack can be configured
with› DDPU› DCOM› DFCU or DFCB.
DDPU
Dual-Duplexer Unit The DDPU performs the following
functions:› Provides lightning protection through the
ANT port › Detect VSWR alarms in the antenna system › Control the gains for the receive low noise
amplifier › Transmits multiple routes of RF signals
from the transmitter to the antenna
DCOM
Combining Unit The DCOM combines two routes of TX
signals from the DTRU, and then sends them to the DDPU
Power Distribution Unit
The power distribution unit consists of the › DC lightning arrester,› EMI filter,› PGND bar,› Busbar terminal socket (top)› Busbar (right)
Lightning protection subrack
The signal lightning protection subrack is installed on top of the cabinet. It is configured with the following boards:› DMLC › DELC › DSAC
DMLC
Monitor Signal Lightning-Protection Card The DMLC performs the following
functions:› Provides lightning protection for Boolean
input and output signals › Provides lightning protection for analog
signals that are transmitted from the smoke sensor, water sensor, door control sensor, infrared sensor, humidity and temperature sensor
DELC
E1 Signal Lightning-Protection Card The DELC performs the following
functions:› Provides lighting protection for E1 signals
DSAC
Signal Access Card
The DSAC performs the following functions:› Provides six Boolean alarm inputs › Provides lightning protection for BITS clock
signals