4
RSR Remote Seismic Recorder 6-channel, 24-bit, A/D Seismic data return (QC only) Robust radio telemetry Post-shot QC attribute return 512-MB flash memory Full instrument and sensor test Vertical/Diversity stack capability • Dynacon TM , amphibious connector (optional) Compatible with the I/O IMAGE TM System Central Electronics and the I/O OCR System Controller Instrument’s performance, response, and testing identical to the MRX TM unit Successful seismic operations require high- equipment utilization, high-productivity recording, and high-quality data. The RSR telemetry is inherently more produtive because spread control is achieved through intrinsi- cally-parallel RF communication. For very large surveys or where RF shadow zones are experienced, one to four RSR Repeaters overcome potential radio-reliability concerns. RSR data quality is assured through extensive self-checking and periodic status-monitoring. The increased efficiency and reliability is made possible by use of privacy codes, sophisticated encoding techniques, and high-sensitivity radio/transceiver design. The RSR system is uniquely suited for work in the most-difficult operations: in RF-congested areas, in environmentally-sensitive wetlands, and in urban areas where recording spread flexibility is required. The RSR system has been used successfully in all types of operations and with all types of sources. RSR-2 RSR-3 © 1999. Input/Output, Inc. All rights reserved. Information subject to change without notice. Revised 06/01. 121001D 1 of 4

-Input[1].Output Inc - Remote.seismic.recorder

Embed Size (px)

Citation preview

Page 1: -Input[1].Output Inc - Remote.seismic.recorder

RSR Remote Seismic Recorder

• 6-channel, 24-bit, A/D

• Seismic data return (QC only)

• Robust radio telemetry

• Post-shot QC attribute return

• 512-MB flash memory

• Full instrument and sensor test

• Vertical/Diversity stack capability

• DynaconTM, amphibious connector (optional)

• Compatible with the I/O IMAGETM System Central Electronics and the I/O OCR System Controller

• Instrument’s performance, response, and testing identical to the MRXTM unit

Successful seismic operations require high-equipment utilization, high-productivity recording, and high-quality data.

The RSR telemetry is inherently more produtive because spread control is achieved through intrinsi-cally-parallel RF communication. For very large surveys or where RF shadow zones are experienced,one to four RSR Repeaters overcome potential radio-reliability concerns. RSR data quality is assuredthrough extensive self-checking and periodic status-monitoring. The increased efficiency and reliabilityis made possible by use of privacy codes, sophisticated encoding techniques, and high-sensitivityradio/transceiver design.

The RSR system is uniquely suited for work in the most-difficult operations: in RF-congested areas,in environmentally-sensitive wetlands, and in urban areas where recording spread flexibility is required.The RSR system has been used successfully in all types of operations and with all types of sources.

RSR-2 RSR-3

© 1999. Input/Output, Inc. All rights reserved. Information subject to change without notice. Revised 06/01. 121001D1 of 4

Page 2: -Input[1].Output Inc - Remote.seismic.recorder

System Highlights

Specifications

INPUT/OUTPUT, INC.

© 1999. Input/Output, Inc. All rights reserved. Information subject to change without notice. Revised 06/01. 121001D2 of 4

Telemetry RF communication link

Seismic Channel Capacity Virtually unlimited

Transmit Frequency 216.02 MHz to 219.98 MHz 216 MHz to 230 MHz available for sales outside of U.S.A. & Canada

(tuned for 216 MHz – 224 MHz or 222 MHz – 230 MHz)1-W output power 20-kHz channel spacing

Calibration Automatic gain calibrationAutomatic DC-offset removal

Shot Status Shot countShot identificationMemory-remainingBattery statusPre-amplifier overdrivesReceive signal strength

Look Ahead Test On-line, full-specification performanceTest of entire channel capacity

Test Capability System dynamic rangeEquivalent input noiseGroup impedanceCommon-mode rejectionCrossfeedDistortionAttenuator step accuracyPulse testHPE-performance testSigna-dependent noise evaluationSpread noise evaluationGeophone performance testAll tests are remotely-selectable and analyzed in the field. Automatic and resident daily, weekly,

monthly, and Look Ahead tests may be selected.

Test Oscillator 79 sine-wave frequencies (7.8 Hz – 960 Hz)Wide spectrum-summed, sine-wave pattern13 pulse patterns (5 widths and 2 types)173 DC levelsAll oscillator signals may be attenuated by a quaternary 11-step attenuator and can be applied

as difference mode or common mode.

A/D Converter 24-bit (23 + sign)

Channels per RSR 6

Pre-amplifier K-Gain 12 dB, 24 dB, 36 dB, or 48 dB

Sample Interval ½ ms, 1 ms, 2 ms, or 4 ms

Channel Capacity Virtually unlimited

Page 3: -Input[1].Output Inc - Remote.seismic.recorder

Specifications (cont.) INPUT/OUTPUT, INC.

© 1999. Input/Output, Inc. All rights reserved. Information subject to change without notice. Revised 06/01. 121001D3 of 4

Line Capacity 65,536

Dynamic RangeNon-shorted input 8.7 Hz – 135 Hz; 650-Ω source; 2-ms sample intervalInstantaneous DR 120.0 dB @ 12-dB K-gain

119.3 dB @ 24-dB K-gain115.0 dB @ 36-dB K-gain104.1 dB @ 48-dB K-gain

Total dynamic range 140.2 dB

Equivalent Input NoiseNon-shorted input 8.7 Hz – 135 Hz; 650-Ω source; 2-ms sample interval

1.408 µVRMS @ 12-dB K-gain0.381 µVRMS @ 24-dB K-gain0.157 µVRMS @ 36-dB K-gain0.137 µVRMS @ 48-dB K-gain

Maximum Input Signal 1408 mVRMS @ 12-dB K-gain352 mVRMS @ 24-dB K-gain88 mVRMS @ 36-dB K-gain22 mVRMS @ 48-dB K-gain3982 mVPP @ 12-dB K-gain996 mVPP @ 24-dB K-gain249 mVPP @ 36-dB K-gain62 mVPP @ 48-dB K-gain

Distortion 0.0005% THD

Channel Gain Matching 0.1%

Common-mode Rejection 100 dB or greater

Crossfeed Isolation 110 dB or greater

Frequency Response 3 Hz – 750 Hz

Time Standard 2 ppm

Input ImpedanceDifferential mode 20 kΩ in parallel with 0.1 µFCommon mode 250 kΩ @ 50 Hz – 60 Hz

RSR Filters All filters are resident and remotely-selectable including:Digital anti-alias filters Linear or minimum phase response

540 Hz or 750 Hz @ ½ ms 270 Hz or 400 Hz @ 1 ms135 Hz or 200 Hz @ 2 ms68 Hz or 100 Hz @ 4 msRejection above Nyquist frequency = –130 dBPassband ripple = ±0.1 dB

Digital low-cut filtersON or OFF, as desired 32 frequencies (3 Hz – 90 Hz)

Slope = 12 dB/octaveDigital hi-line pickup eliminator (HPE)

ON or OFF, as desired Simultaneous cancellation of 3 selectable frequenciesFixed frequencies Selectable; 3 Hz to 420 Hz (0.01-Hz increments)Rejection 80 dB or greater

Page 4: -Input[1].Output Inc - Remote.seismic.recorder

Specifications (cont.) INPUT/OUTPUT, INC.

United States – Stafford, TXInput/Output, Inc.Fax: 281.879.3500Phone: 281.933.3339E-mail: [email protected]

RussiaInput/Output, Inc.Fax: 7.095.2322240Phone: 7.095.2322254

EnglandInput/Output, Inc.Fax: 44.1603.411403Phone: 44.1603.411400

Web Sitewww.i-o.com

© 1999. Input/Output, Inc. All rights reserved. Information subject to change without notice. Revised 06/01. 121001D4 of 4

RSR Unit (P/N 139000)Dimensions 24.4 cm x 24.4 cm x 20 cm (9.6 in x 9.6 in x 7.9 in)Weight 6.8 kg (15 lb)Temperature –50°C to +75°C Humidity 0% to 100%Altitude Up to 5,500 mPower 12-V battery (optional solar)

DCU (P/N 139500)Dimensions 39.1 cm x 18.3 cm x 27.4 cm (15.4 in x 7.2 in x 10.8 in)Weight 10 kg (22 lb)Temperature +5°C to +45°C Humidity 0% to 100%Altitude Up to 5,500 mPower 12-V battery (optional solar)

RSR Repeater & Duplexer (P/N 151001)RSR Repeater

Dimensions 24.3 cm x 24.3 cm x 19 cm (9.6 in x 9.6 in x 7.5 in)Weight 5.9 kg (13 lb)Temperature –50°C to +75°C Humidity 0% to 100%Altitude Up to 5,500 mPower 12-V battery (optional solar)

RSR DuplexerDimensions 38.8 cm x 58.4 cm x 63.6 cm (15.25 in x 23 in x 25 in)Weight 25.9 kg (57 lb)Temperature –50°C to +75°C Humidity 0% to 100%Altitude Up to 5,500 m

Remote Test Station (RTS; P/N 142000) Retrieves RSR status Performs following tests on RSR:

Dynamic range determination RMS noise Frequency response Common-mode rejection Harmonic distortion HPE performance Crossfeed box and group Signal-dependent noise evaluation

Related Products I/O IMAGETM System Central Electronics; MRXTM Miniature Remote Signal Condition-er; OCR System Controller; 12-V batteries & chargers