Features
Tubular Technology Deep cycle design (600 700 cycles at 80% D.O.D.)
Minimum maintenance Abuse resistant
Electrolyte level indicator Faster recharge
Suited for f requent and long pow ercuts Operating sp.gr. 1.250 0.005 at 27C
More than 20% extra electrolyte w hich means lesser topping-upfr equency and better thermal management.
Technical Specification
Model Capacity* Dimension (+/-3mm) Weight(Kg +/-5%)
Volumeof Electrolyte(1.220Sp. Gr)Liters/Cell
InitialchargeMinimumAH input(AH)
InitialCharge of ConstantCurrent (A)
ConstantPotentialLimitingCurrent(Amps)
TrickleCharg(CurremA)
Length Width Height* Dry Filied
Start(upto2.36vpc)
Finish(upto2.75vpc) Min.
INVAMASTER3000 80 Ah 410 176 281 18.40 30.10 1.60 315 8.40 4.20 17.50 70 280
INVAMASTER4000 100 Ah 410 176 281 24.00 43.00 2.60 396 10.60 5.30 22.00 88 352
INVAMASTER
4000T 115 Ah 500 187 416 29.00 53.80 3.38 450 12.00 6.00 25.00 100 400
INVAMASTER
Inverter
Welcome to Exide I ndustries L imited, India... July 25, 201 4 9:19:35 PM
Home Contact us Sitemap OUR CORPORATE W EBSITE
ENERAL
Corporate Overview
Manufacturing
Acc reditations
Financials
Social Responsibility
News & View s
Battery Recyc ling
NDUSTRIAL
Technology
Application & Products
Battery Sizing
Post An Enquiry
Battery Servicing
Loc ate a Dealer
Contact Us
FAQsXIDE 4 U
My Exid e
Employ ee CRM
e-learning
You are here: Home > Industrial > Application & Products > Stand By > Inverter
http://www.exide4u.com/exide/surveyedQuestion.do?method=LoadSurveyedQuestionhttp://www.exide4u.com/exide/surveyedQuestion.do?method=LoadSurveyedQuestionhttp://www.exide4u.com/exide/JSP/masters/elearninglogin.jsphttp://www.exide4u.com/exide/locate.do?method=loadCityhttp://www.exide4u.com/exide/query.dohttp://www.exide4u.com/exide/opinionpole.do?method=loadQuestionhttp://www.exide4u.com/exide/surveyedQuestion.do?method=LoadSurveyedQuestionhttp://www.exide4u.com/exide/JSP/masters/elearninglogin.jsphttp://crmdevtrx.crmdev.com:50000/irj/portalhttp://www.exide4u.com/exide/JSP/masters/login.jsphttp://www.exide4u.com/exide/JSP/masters/faq/faq.htmhttp://www.exide4u.com/exide/locate.do?method=loadCityhttp://www.exide4u.com/exide/query.dohttp://www.exideindustries.com/http://www.exide4u.com/exide/JSP/masters/Sitemap/sitemap.htmhttp://www.exide4u.com/exide/JSP/masters/Contactus/corpo_office.htmhttp://www.exide4u.com/exide/opinionpole.do?method=loadQuestionhttp://www.exide4u.com/exide/locate.do?method=loadCity8/10/2019 ._ EXIDE _2
2/2
5000 115 Ah 535 222 275 27.00 40.50 1.85 450 12.00 6.00 25.00 100 400
INVAMASTER7500 135 Ah 535 222 275 29.50 47.50 2.47 531 14.00 7.00 29.50 118 475
INVAMASTER8500 150 Ah 535 222 275 32.50 50.10 2.40 563 15.00 7.50 31.00 125 500
INVAMASTER10000 150 Ah 500 187 416 33.77 59.81 3.43 540 14.40 7.20 30.00 120 480
INVAMASTER15000 200 Ah 500 187 416 45.00 72.00 3.60 720 19.20 9.60 40.00 160 640
INVAMASTER20000 200 Ah 500 187 416 41.44 66.50 3.30 810 21.60 10.80 45.00 180 720
*The height mentioned is upto terminal top. *At 27 0C when discharged at C20 upto 1.75 vpc (1.280 sp.gr)
Initial Charging Instructions
1. Filling in Specif ic Gravity 1.220 +/ - 0.005 at 27C
2. Rest Period 10 hrs
3. Minimum Ah input 315 Ah for IM3000, 396 Ah for IM4000, 450 Ahfor IM5000, 531 Ah for IM7500, 540 Ah IM10000
4. In order to reduce the charging time, the follow ing routine may be adopted. For IM3000, the initial charging current may be 8.4A upto 2.36vpc f ollow ed by 4.2A upto 2.75 vpc . For IM4000, the initial charging current may be 10.6A upto 2.36 vpc f ollow ed by 5.3A upto 2.75 vpc.For IM5000, the initial charging curr ent may be 12A upto 2.36 vpc, follow ed by 6A upto 2.75 vpc . For IM7500, the initial charging curr entmay be 14A upto 2.36 vpc, f ollow ed by 7A upto 2.75 vpc. For IM10000, the initial charging current may be 14.4A upto 2.36 vpc, f ollow edby 7.2A upto 2.75 vpc.
However, in both cases, minimum Ah input to be given. Under no circumstances, battery temperature should not exc eed 50 0C. In catemperature exceeds 50 0C adequate rest to be given till the electrolyte temp. comes to ambient temp. and charging to be continued.
5. Condit ions of fully charged
3 consecutive hourly readings of specific gravity and voltage become constant.
Top of charge voltage w ill e around 16.2V 16.5V.
All cells should gas f reely.
Minimum Ah has been given.
6. Specif ied gravity of fully charged condition 1.250 +/ - 0.005 at 27C
Normal Recharging Instructions
Recharging through Inverter at constant potential mode of 14.4V w ith limited curr ent as specif ied. After battery potential reaches 14.4V, the batteryshould continue in float charge made at constant potential of 13.5V.
Statutory Notice
All batteries contain lead, w hich is harmful for humans and environment. As per s tatutory requirements, the used battery must be returned to theauthorized dealer, manufacturer or at the designated collection centres .