20
COOK FANS www.lorencook.com ECCO Supply™ www.eccosupply.ca 12-1 Expert Service. Quality Products. Since 1960. Revised: July 2015 • Replaces: March 2011 AIR CIRCULATOR FANS AIR CIRCULATOR FAN HEADS — CAC ............................................ 12-19 MOUNTABLE MINI-BLOWER FAN HEADS...................................... 12-19 MOUNTED BLOWER FAN HEADS ..................................................... 12-19 PORTABLE BLOWERS............................................................................. 12-20 SUSPENDABLE BLOWER ...................................................................... 12-20 CEILING, WALL AND DUCT TRANSFER FANS AIR CURTAIN ............................................................................................... 12-5 CINDER BLOCK SIZED FAN — CBF..................................................... 12-5 DUCT BLOWERS DB AND DBX ......................................................................................... 12-5 SDB ........................................................................................................... 12-5 TDB (DOUBLE WIDE) .......................................................................... 12-5 “GEMINI” ROOM EXHAUSTS — GC AND GN .................................. 12-4 CENTRIFUGAL AND CENTRI-VANE® INLINE BLOWERS CENTRI-VANE INLINE — CVD .............................................................. 12-8 MULTI-DIRECTIONAL SQUARE CENTRIFUGAL — SQN ............. 12-7 SQUARE CENTRIFUGAL — SQI............................................................ 12-7 TUBULAR CENTRIFUGAL INLINE — TCN ......................................... 12-7 CENTRIFUGAL ROOF AND WALL EXHAUSTERS DOWNBLAST — ACE ............................................................................... 12-2 FIBERGLASS ................................................................................................ 12-3 LOW CONTOUR HOODED OR TIERED .............................................. 12-4 LOW PROFILE — LP ................................................................................. 12-4 RESTAURANT UPBLAST — VCR........................................................... 12-3 SMOKE CONTROL UPBLAST — ACSC (ACSC, ACSC-HP AND ACSC-XP) ..................................... 12-3 TAMPER RESISTANT DOWNBLAST — SRSH ................................... 12-3 UPBLAST — ACRU.................................................................................... 12-2 WALL — ACW............................................................................................. 12-2 CENTRIFUGAL UTILITY VENT SETS ........................................................... 12-14 INDUSTRIAL BLOWERS, PLUG AND PLENUM FANS DOUBLE WIDTH DOUBLE INLET ....................................................... 12-15 MATERIAL-LADEN AIR HANDLERS — MH .................................... 12-16 PLENUM FANS — PLC ........................................................................... 12-16 PLUG FANS — CCP ................................................................................. 12-16 SINGLE WIDTH SINGLE INLET — CA/CF ........................................ 12-15 LAB EXHAUST SYSTEMS LAB EXHAUST CURB — LEC ............................................................... 12-17 LE SERIES.................................................................................................... 12-17 POWER-PLUME®— PP .......................................................................... 12-17 VARI-PLUME®............................................................................................ 12-17 MIXED-FLOW INLINE BLOWERS — QMX................................................ 12-8 PROPELLER / AXIAL INLINE FANS ADJUSTABLE VANE AXIAL CAST ALUMINUM AIRFOIL PROP... 12-12 PROPELLOR / AXIAL INLINE FANS (cont'd) FIXED PITCH VANE AXIAL CAST ALUMINUM AIRFOIL PROP.... 12-12 FIXED TUBE AXIAL .................................................................................. 12-12 TUBE AXIAL CAST ALUMINUM PROP — A SERIES ................... 12-11 TUBE AXIAL EXTRUDED ALUMINUM PROP — E SERIES ........ 12-11 TUBE AXIAL STEEL PROP — TRITON® SERIES ............................. 12-11 PROPELLER ROOF FANS A SERIES CAST ALUMINUM PROP .................................................... 12-12 E SERIES EXTRUDED ALUMINUM PROP ........................................ 12-12 HOODED “ECONOMIZER”.................................................................... 12-13 HOODED BELT DRIVE — “H SERIES” .................................. 12-13 –12-14 HOODED DIRECT DRIVE — “H SERIES” .......................................... 12-13 “REBEL" STAMPED ALUMINUM PROP ............................................. 12-13 PROPELLER UPBLAST FANS AND CURBS CAST ALUMINUM PROP — A SERIES .............................................. 12-11 CURBS ......................................................................................................... 12-11 EXTRUDED ALUMINUM PROP — E SERIES .................................. 12-10 STEEL PROP — TRITON® SERIES ....................................................... 12-10 STEEL PROP — X.STREAM SERIES.................................................... 12-10 PROPELLER WALL FANS A SERIES CAST ALUMINUM PROP APD AND APB PACKAGED FANS ................................................... 12-6 AWD AND AWB .................................................................................... 12-6 E SERIES EXTRUDED ALUMINUM PROP EPD AND EPB PACKAGED FANS .................................................... 12-7 EWD AND EWB ..................................................................................... 12-7 X SERIES ALUMINUM PROP XPD PACKAGED FAN (DIRECT DRIVE) ......................................... 12-5 XWD (DIRECT DRIVE) ......................................................................... 12-5 X.STREAM SERIES STEEL PROP XLP AND XMP PACKAGED FANS (STANDARD DUTY) .......... 12-6 XLPH AND XMPH PACKAGED FANS (HEAVY DUTY) ............. 12-6 XLW AND XMW (STANDARD DUTY) ............................................ 12-6 XLWH AND XMWH (HEAVY DUTY)............................................... 12-6 ROOF MOUNTED BLOWERS CENTRI-VANE ROOF MOUNTED — CV ............................................ 12-9 MIXED-FLOW ROOF MOUNTED — QMX ........................................ 12-9 SUPPLY, ENERGY RECOVERY, MAKEUP, AND GRAVITY BACKWARD INCLINED FILTERED SUPPLY — CFS ...................... 12-18 DIRECT FIRE HEATED MAKEUP — ERV .......................................... 12-18 ENERGY RECOVERY — ERV ................................................................ 12-18 FORWARD CURVED FILTERED KITCHEN SUPPLY — KSP ........ 12-18 FORWARD CURVED SUPPLY — ASP ............................................... 12-18 GRAVITY VENTILATION.......................................................... 12-18 –12-19 Available in Northern Alberta and British Columbia. Call your local ECCO Supply™ Sales Representative for pricing and additional information. For technical information visit www.lorencook.com. INDEX

- ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

Embed Size (px)

Citation preview

Page 1: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

ECCO Supply™ www.eccosupply.ca 12-1

Expert Service. Quality Products. Since 1960.

Revised: July 2015 • Replaces: March 2011

AIR CIRCULATOR FANSAIR CIRCULATOR FAN HEADS — CAC ............................................ 12-19MOUNTABLE MINI-BLOWER FAN HEADS ...................................... 12-19MOUNTED BLOWER FAN HEADS ..................................................... 12-19PORTABLE BLOWERS............................................................................. 12-20SUSPENDABLE BLOWER ...................................................................... 12-20

CEILING, WALL AND DUCT TRANSFER FANSAIR CURTAIN ............................................................................................... 12-5CINDER BLOCK SIZED FAN — CBF ..................................................... 12-5DUCT BLOWERS

DB AND DBX ......................................................................................... 12-5SDB ........................................................................................................... 12-5TDB (DOUBLE WIDE) .......................................................................... 12-5

“GEMINI” ROOM EXHAUSTS — GC AND GN .................................. 12-4

CENTRIFUGAL AND CENTRI-VANE® INLINE BLOWERSCENTRI-VANE INLINE — CVD .............................................................. 12-8MULTI-DIRECTIONAL SQUARE CENTRIFUGAL — SQN ............. 12-7SQUARE CENTRIFUGAL — SQI ............................................................ 12-7TUBULAR CENTRIFUGAL INLINE — TCN ......................................... 12-7

CENTRIFUGAL ROOF AND WALL EXHAUSTERSDOWNBLAST — ACE ............................................................................... 12-2FIBERGLASS ................................................................................................ 12-3LOW CONTOUR HOODED OR TIERED .............................................. 12-4LOW PROFILE — LP ................................................................................. 12-4RESTAURANT UPBLAST — VCR ........................................................... 12-3SMOKE CONTROL UPBLAST —

ACSC (ACSC, ACSC-HP AND ACSC-XP) ..................................... 12-3TAMPER RESISTANT DOWNBLAST — SRSH ................................... 12-3UPBLAST — ACRU.................................................................................... 12-2WALL — ACW............................................................................................. 12-2

CENTRIFUGAL UTILITY VENT SETS ........................................................... 12-14INDUSTRIAL BLOWERS, PLUG AND PLENUM FANS

DOUBLE WIDTH DOUBLE INLET ....................................................... 12-15MATERIAL-LADEN AIR HANDLERS — MH .................................... 12-16PLENUM FANS — PLC ........................................................................... 12-16PLUG FANS — CCP ................................................................................. 12-16SINGLE WIDTH SINGLE INLET — CA/CF ........................................ 12-15

LAB EXHAUST SYSTEMSLAB EXHAUST CURB — LEC ............................................................... 12-17LE SERIES .................................................................................................... 12-17POWER-PLUME®— PP .......................................................................... 12-17VARI-PLUME® ............................................................................................ 12-17

MIXED-FLOW INLINE BLOWERS — QMX................................................ 12-8PROPELLER / AXIAL INLINE FANS

ADJUSTABLE VANE AXIAL CAST ALUMINUM AIRFOIL PROP ... 12-12

PROPELLOR / AXIAL INLINE FANS (cont'd)FIXED PITCH VANE AXIAL CAST ALUMINUM AIRFOIL PROP .... 12-12FIXED TUBE AXIAL .................................................................................. 12-12TUBE AXIAL CAST ALUMINUM PROP — A SERIES ................... 12-11TUBE AXIAL EXTRUDED ALUMINUM PROP — E SERIES ........ 12-11TUBE AXIAL STEEL PROP — TRITON® SERIES ............................. 12-11

PROPELLER ROOF FANSA SERIES CAST ALUMINUM PROP .................................................... 12-12E SERIES EXTRUDED ALUMINUM PROP ........................................ 12-12HOODED “ECONOMIZER” .................................................................... 12-13HOODED BELT DRIVE — “H SERIES” .................................. 12-13 –12-14 HOODED DIRECT DRIVE — “H SERIES” .......................................... 12-13“REBEL" STAMPED ALUMINUM PROP ............................................. 12-13

PROPELLER UPBLAST FANS AND CURBSCAST ALUMINUM PROP — A SERIES .............................................. 12-11CURBS ......................................................................................................... 12-11EXTRUDED ALUMINUM PROP — E SERIES .................................. 12-10STEEL PROP — TRITON® SERIES ....................................................... 12-10STEEL PROP — X.STREAM SERIES .................................................... 12-10

PROPELLER WALL FANSA SERIES CAST ALUMINUM PROP

APD AND APB PACKAGED FANS ................................................... 12-6AWD AND AWB .................................................................................... 12-6

E SERIES EXTRUDED ALUMINUM PROPEPD AND EPB PACKAGED FANS .................................................... 12-7EWD AND EWB ..................................................................................... 12-7

X SERIES ALUMINUM PROPXPD PACKAGED FAN (DIRECT DRIVE) ......................................... 12-5XWD (DIRECT DRIVE) ......................................................................... 12-5

X.STREAM SERIES STEEL PROPXLP AND XMP PACKAGED FANS (STANDARD DUTY) .......... 12-6XLPH AND XMPH PACKAGED FANS (HEAVY DUTY) ............. 12-6XLW AND XMW (STANDARD DUTY) ............................................ 12-6XLWH AND XMWH (HEAVY DUTY) ............................................... 12-6

ROOF MOUNTED BLOWERSCENTRI-VANE ROOF MOUNTED — CV ............................................ 12-9MIXED-FLOW ROOF MOUNTED — QMX ........................................ 12-9

SUPPLY, ENERGY RECOVERY, MAKEUP, AND GRAVITY BACKWARD INCLINED FILTERED SUPPLY — CFS ...................... 12-18DIRECT FIRE HEATED MAKEUP — ERV .......................................... 12-18ENERGY RECOVERY — ERV ................................................................ 12-18FORWARD CURVED FILTERED KITCHEN SUPPLY — KSP ........ 12-18FORWARD CURVED SUPPLY — ASP ............................................... 12-18GRAVITY VENTILATION.......................................................... 12-18 –12-19

Available in Northern Alberta and British Columbia. Call your local ECCO Supply™ Sales Representative for pricing and additional information. For technical information visit www.lorencook.com.

INDEX

Page 2: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-2 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

CENTRIFUGAL ROOF AND WALL EXHAUSTERSDOWNBLAST — ACEDirect Drive (ACED)• Wheel Sizes: 7 – 18"• Capacity: 80 – 4,200 CFM• Static Pressure: 0 – 1.5"

Direct Drive EC (ACED-EC)• Wheel Sizes: 7 – 15"• Capacity: 70 – 2,600 CFM• Static Pressure: 0 – 1.5"

Belt Drive (ACEB)• Wheel Sizes: 10 – 54"• Capacity: 50 – 32,000 CFM• Static Pressure: 0 – 1.5"

WALL — ACWSTANDARD WHEEL:Direct Drive (ACWD)• Wheel Sizes: 7 – 18"• Capacity: 60 – 4,300 CFM• Static Pressure: 0 – 1.5"

Direct Drive EC (ACWD-EC)• Wheel Sizes: 7 – 15"• Capacity: 80 – 2,500 CFM• Static Pressure: 0 – 1.5"

Belt Drive (ACWB)• Wheel Sizes: 10 – 24.5"• Capacity: 280 – 8,200 CFM• Static Pressure: 0 – 1.5"

HIGH PRESSURE WHEEL:Direct Drive (ACWD-HP)• Wheel Size: 15 – 19.5"• Capacity: 570 – 3,700 CFM• Static Pressure: 0.125 – 1.75"

Direct Drive EC (ACWDEC-HP)• Wheel Sizes: 15"• Capacity: 360 – 1,600 CFM• Static Pressure: 0 – 1.5"

Belt Drive (ACWB-HP)• Wheel Sizes: 15 – 36.5"• Capacity: 340 – 19,000 CFM• Static Pressure: 0.25 – 2.5"

EXTENDED PRESSURE WHEEL:Direct Drive (ACWD-XP)• Wheel Sizes: 16.5 – 19.5"• Capacity: 520 – 2,200 CFM• Static Pressure: 0.125 – 1.75"

Direct Drive EC (ACWDEC-XP)• Wheel Sizes: 16.5 – 18"• Capacity: 350 – 1,900 CFM• Static Pressure: 0 – 1.5"

Belt Drive (ACWB-XP)• Wheel Sizes: 16.5 – 24.5"• Capacity: 520 – 4,500 CFM• Static Pressure: 1 – 4.5"

UPBLAST — ACRUSTANDARD WHEEL:Direct Drive (ACRUD)• Wheel Sizes: 7 – 18"• Capacity: 60 – 4,300 CFM• Static Pressure: 0 – 1.5"

Direct Drive EC (ACRUD-EC)• Wheel Sizes: 7 – 15"• Capacity: 80 – 2,500 CFM• Static Pressure: 0 – 1.5"

Belt Drive (ACRU)• Wheel Sizes: 10 – 49"• Capacity: 280 – 28,000 CFM• Static Pressure: 0 – 1.5"

HIGH PRESSURE WHEEL:Direct Drive (ACRUD-HP)• Wheel Sizes: 15 – 19.5"• Capacity: 580 – 3,700 CFM• Static Pressure: 0.25 – 1.75"

Direct Drive EC (ACRUDEC-HP)• Wheel Sizes: 15"• Capacity: 360 – 1,600 CFM• Static Pressure: 0 – 1.5"

Belt Drive (ACRU-HP)• Wheel Size: 15 – 36.5"• Capacity: 340 – 19,000 CFM• Static Pressure: 0.25 – 2.5"

EXTENDED PRESSURE WHEEL:Direct Drive (ACRUD-XP)• Wheel Sizes: 16.5 – 19.5"• Capacity: 520 – 2,200 CFM• Static Pressure: 0.125 – 1.75"

Direct Drive (ACRUDEC-XP)• Wheel Sizes: 16.5 – 18"• Capacity: 350 – 1,900 CFM• Static Pressure: 0 – 1.5"

Belt Drive (ACRU-XP)• Wheel Size: 16.5 – 36.5"• Capacity: 520 – 11,000 CFM• Static Pressure: 1 – 4.5"

Page 3: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-3

Revised: July 2015 • Replaces: March 2011

CENTRIFUGAL ROOF AND WALL EXHAUSTERS (cont’d)SMOKE CONTROL UPBLAST — ACSC (ACSC, ACSC-HP AND ACSC-XP)These have the same availability and performance as the ACRU, ACRU-HP and ACRU-XP.

RESTAURANT UPBLAST — VCRSTANDARD WHEEL:Direct Drive (VCRD)• Wheel Sizes: 10.1 – 18"• Capacity: 400 – 4,300 CFM• Static Pressure: 0 – 1.5"

Direct Drive (VCRD-EC)• Wheel Sizes: 10.1 – 15"• Capacity: 260 – 2,500 CFM• Static Pressure: 0 – 1.5"

Belt Drive (VCR)• Wheel Sizes: 10 – 49"• Capacity: 280 – 28,000 CFM• Static Pressure: 0 – 1.5"

HIGH PRESSURE WHEEL:Direct Drive (VCRD-HP)• Wheel Sizes: 15 – 19.5"• Capacity: 580 – 3,700 CFM• Static Pressure: 0.125 – 1.75"

Direct Drive (VCRDEC-HP)• Wheel Sizes: 15"• Capacity: 360 – 1,600 CFM• Static Pressure: 0 – 1.5"

Belt Drive (VCR-HP)• Wheel Sizes: 15 – 36.5"• Capacity: 340 – 19,000 CFM• Static Pressure: 0.25 – 2.5"

EXTENDED PRESSURE WHEEL:Direct Drive (VCRD-XP)• Wheel Sizes: 16.5 – 19.5"• Capacity: 520 – 2,200 CFM• Static Pressure: 0.12 – 1.75"

Direct Drive (VCRDEC-XP)• Wheel Sizes: 16.5 – 18"• Capacity: 350 – 1,900 CFM• Static Pressure: 0 – 1.5"

Belt Drive (VCR-XP)• Wheel Sizes: 16.5 – 36.5"• Capacity: 520 – 11,000 CFM• Static Pressure: 1 – 4.5"

TAMPER RESISTANT DOWNBLAST — SRSHDirect Drive (SRSHD)• Wheel Sizes: 10 – 18"• Capacity: 30 – 7,000 CFM• Static Pressure: 0 – 1.5"

Belt Drive (SRSHB)• Wheel Size: 10 – 27"• Capacity: 30 – 10,000 CFM• Static Pressure: 0 – 1.5"

FIBERGLASSFCE (DOWNBLAST)Direct Drive (FCE-D)• Wheel Sizes: 12 – 18"• Capacity: 350 – 3,400 CFM• Static Pressure: 0 – 3"

Belt Drive (FCE-B)• Wheel Sizes: 12 – 40"• Capacity: 150 – 21,000 CFM• Static Pressure: 0 – 3"

FCRU (UPBLAST)Direct Drive (FCRU-D)• Wheel Sizes: 12 – 18"• Capacity: 350 – 3,600 CFM• Static Pressure: 0 – 6"

Belt Drive (FCRU-B)• Wheel Sizes: 12 – 40"• Capacity: 150 – 22,000 CFM• Static Pressure: 0 – 6"

FCE FCRU

Page 4: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-4 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

“GEMINI” ROOM EXHAUSTS — GC AND GNSIZE: 126 – 188Ceiling (GC)• Capacity: 30 – 260 CFM• Static Pressure: 0 – 1"

Inline (GN)• Capacity: 40 – 260 CFM• Static Pressure: 0 – 1"

SIZE: 822 – 960Ceiling or Wall (GC)• Capacity: 640 – 1,800 CFM• Static Pressure: 0 – 1"

Inline (GN)• Capacity: 760 – 1,800 CFM• Static Pressure: 0 – 1"

SIZE: 222 – 740Ceiling or Wall (GC)• Capacity: 80 – 830 CFM• Static Pressure: 0 – 1"

Inline (GN)• Capacity: 80 – 870 CFM• Static Pressure: 0 – 1"

SIZE: 1000 – 2000Ceiling or Wall (GC)Inline (GN)• Static Pressure: 0.1 – 1"• Capacity: 1,100 – 3,400 CFM

CENTRIFUGAL ROOF AND WALL EXHAUSTERS (cont’d)LOW PROFILE — LPDirect Drive (LPD)• Wheel Sizes: 10 – 16.5"• Capacity: 200 – 2,800 CFM• Static Pressure: 0 – 1"

Belt Drive (LPB)• Wheel Sizes: 10 – 54"• Capacity: 315 – 53,000 CFM• Static Pressure: 0 – 2.5"

HLC

126 – 188

222 – 740

822 – 960

1000 – 2000

TLC

TLCH

CEILING, WALL AND DUCT TRANSFER FANS

LOW CONTOUR HOODED OR TIEREDHLC (HOODED)Direct Drive (HLC-D)• Wheel Sizes: 7 – 18"• Capacity: 30 – 3,800 CFM• Static Pressure: 0 – 1.5"

Belt Drive (HLC-B)• Wheel Sizes: 10 – 54"• Capacity: 230 – 42,000 CFM• Static Pressure: 0 – 2"

TLC (TIERED)Direct Drive (TLC-D)• Wheel Sizes: 7 – 18"• Capacity: 40 – 3,600 CFM• Static Pressure: 0 – 1.25"

Belt Drive (TLC-B)• Wheel Sizes: 10 – 54"• Capacity: 280 – 43,000 CFM• Static Pressure: 0 – 2"

TLCH (HURRICANE RESISTANT TIERED)Direct Drive (TLCH-D)• Wheel Sizes: 7 – 18"• Capacity: 40 – 3,600 CFM• Static Pressure: 0 – 1.25"

Belt Drive (TLCH-B)• Wheel Sizes: 10 – 36.5"• Capacity: 280 – 22,000 CFM• Static Pressure: 0 – 2"

Page 5: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-5

Revised: July 2015 • Replaces: March 2011

CEILING, WALL AND DUCT TRANSFER FANS (cont’d)DUCT BLOWERS — DB AND DBXBelt Drive (DB)External Belt Drive (DBX)• Wheel Sizes: 8 – 18"• Capacity: 300 – 9,400 CFM• Static Pressure: 0.125 – 2"

DUCT BLOWERS — SDB• Wheel Sizes: 10 – 24.5"• Capacity: 300 – 14,400 CFM• Static Pressure: 0.250 – 3"

DUCT BLOWERS — TDB (DOUBLE WIDE)• Wheel Sizes: 8 – 18"• Capacity: 800 – 15,500 CFM• Static Pressure: 0.125 – 2"

CINDER BLOCK SIZED FAN — CBF• Capacity: 70 – 530 CFM• Static Pressure: 0 – 0.4"

AIR CURTAIN• Max. Capacity: 3,200 CFM

PROPELLER WALL FANSX SERIES ALUMINUM PROP — XWD (DIRECT DRIVE)Standard (XWD)• Prop Sizes: 8 – 24"• Capacity: 80 – 6,600 CFM• Static Pressure: 0 – 0.5"

Heavy Duty (XWHD)• Prop Sizes: 12 – 24"• Capacity: 290 – 8,000 CFM• Static Pressure: 0 – 0.75"

X SERIES ALUMINUM PROP — XPD PACKAGED FAN (DIRECT DRIVE)Includes a standard wall fan in a galvanized steel enclosure, integral mounting flange, and weather-resistant shutter.

Standard (XPD)• Prop Sizes: 8 – 24"• Capacity: 80 – 6,600 CFM• Static Pressure: 0 – 0.5"

Heavy Duty (XPHD)• Prop Sizes: 12 – 24"• Capacity: 290 – 8,000 CFM• Static Pressure: 0 – 0.75"

Page 6: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-6 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

PROPELLER WALL FANS (cont’d)X.STREAM SERIES STEEL PROP — XLW AND XMW (STANDARD DUTY)Low Pressure Prop (XLW)• Capacity: 1,100 – 33,000 CFM• Static Pressure: 0 – 0.5"• Belt Drive• Prop Sizes: 20 – 60"

Medium Pressure Prop (XMW)• Capacity: 1,400 – 33,000 CFM• Static Pressure: 0 – 1"• Belt Drive• Prop Sizes: 20 – 60"

X.STREAM SERIES STEEL PROP — XLWH AND XMWH (HEAVY DUTY)Low Pressure Prop (XLWH)• Capacity: 1,400 – 59,000 CFM• Belt Drive• Prop Sizes: 20 – 60"• Static Pressure: 0 – 1"

Medium Pressure Prop (XMWH)• Capacity: 1,800 – 57,000 CFM• Belt Drive• Prop Sizes: 20 – 60"• Static Pressure: 0 – 1"

X.STREAM SERIES STEEL PROP — XLP AND XMP PACKAGED FANS (STANDARD DUTY) Includes a standard wall fan in a galvanized steel enclosure, integral mounting flange, and weather-resistant shutter.Low Pressure Prop (XLP)• Capacity: 1,100 – 28,000 CFM• Static Pressure: 0 – 0.5"• Belt Drive• Prop Sizes: 20 – 60"

Medium Pressure Prop (XMP)• Capacity: 1,400 – 27,000 CFM• Static Pressure: 0 – 1"• Belt Drive• Prop Sizes: 20 – 60"

X.STREAM SERIES STEEL PROP — XLPH AND XMPH PACKAGED FANS (HEAVY DUTY) Includes a standard wall fan in a galvanized steel enclosure, integral mounting flange, and weather-resistant shutter.Low Pressure Prop (XLPH)• Capacity: 2,100 – 49,000 CFM• Static Pressure: 0 – 0.75"• Belt Drive• Prop Sizes: 20 – 60"

Medium Pressure Prop (XMPH)• Capacity: 3,500 – 46,000 CFM• Static Pressure: 0 – 1"• Belt Drive• Prop Sizes: 20 – 60"

A SERIES CAST ALUMINUM PROP — AWD AND AWBDirect Drive (AWD)• Prop Sizes: 12 – 48"• Capacity: 360 – 33,000 CFM• Static Pressure: 0 – 0.75"

Belt Drive (AWB)• Prop Sizes: 24 – 48"• Capacity: 2,100 – 42,000 CFM• Static Pressure: 0 – 0.5"

A SERIES CAST ALUMINUM PROP — APD AND APB PACKAGED FANSIncludes a standard wall fan in a galvanized steel enclosure, integral mounting flange, and weather-resistant shutter.Direct Drive (APD)• Prop Sizes: 16 – 36"• Capacity: 850 – 12,000 CFM• Static Pressure: 0 – 0.375"

Belt Drive (APB)• Prop Sizes: 24 – 48"• Capacity: 1,400 – 20,000 CFM• Static Pressure: 0 – 0.375"

Page 7: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-7

Revised: July 2015 • Replaces: March 2011

TUBULAR CENTRIFUGAL INLINE — TCNTCN-D (DIRECT DRIVE)Standard Wheel (TCN-D)• Capacity: 90 – 5,000 CFM• Wheel Sizes: 6 – 16.5"• Static Pressure: 0 – 3"

High Pressure Wheel (TCNH-D)• Capacity: 90 – 4,500 CFM• Wheel Sizes: 6 – 16.5"• Static Pressure: 0 – 3"

TCN-B (BELT DRIVE)Standard Wheel (TCN-B)• Capacity: 50 – 41,000 CFM• Static Pressure: 0 – 2.5"• Wheel Sizes: 6 – 49"

High Pressure Wheel (TCNH-B)• Capacity: 30 – 46,000 CFM• Static Pressure: 1– 4"• Wheel Sizes: 6 – 49"

MULTI-DIRECTIONAL SQUARE CENTRIFUGAL — SQNSQN-D (DIRECT DRIVE)Standard Wheel (SQN-D)• Wheel Sizes: 7 – 16.5"• Capacity: 30 – 4,300 CFM• Static Pressure: 0 – 2"

Standard Wheel with EC motor (SQND-EC)• Wheel Sizes: 7 – 15"• Capacity: 70 – 2,500 CFM• Static Pressure: 0 – 1.25"

SQN-B (BELT DRIVE)Standard Wheel (SQN-B)• Wheel Sizes: 10 – 40.2"• Capacity: 35 – 26,000 CFM• Static Pressure: 0.125 – 3"

High Pressure Wheel (SQN-HP)• Wheel Sizes: 13.5 – 40.2"• Capacity: 1,000 – 22,000 CFM• Static Pressure: 0.25 – 5"

PROPELLER WALL FANS (cont’d)E SERIES EXTRUDED ALUMINUM PROP — EWD AND EWBDirect Drive (EWD)• Prop Sizes: 20 – 54"• Capacity: 680 – 59,000 CFM• Static Pressure: 0 – 1"

Belt Drive (EWB)• Prop Sizes: 24 – 72"• Capacity: 1,200 – 95,000 CFM• Static Pressure: 0 – 1.5"

E SERIES EXTRUDED ALUMINUM PROP — EPD AND EPB PACKAGED FANSIncludes a standard wall fan in a galvanized steel enclosure, integral mounting flange, and weather-resistant shutter.Direct Drive (EPD)• Prop Sizes: 20 – 54"• Capacity: 1,500 – 50,000 CFM• Static Pressure: 0 – 1"

Belt Drive (EPB)• Prop Sizes: 24 – 72"• Capacity: 480 – 80,000 CFM• Static Pressure: 0 – 0.75"

CENTRIFUGAL AND CENTRI-VANE® INLINE BLOWERSSQUARE CENTRIFUGAL — SQISQI-D (DIRECT DRIVE)Standard Wheel• Wheel Sizes: 7 – 16.5"• Capacity: 50 – 4,900 CFM• Static Pressure: 0 – 2"

SQI-B (BELT DRIVE)Standard Wheel (SQI-B)• Wheel Sizes: 9 – 40.2"• Capacity: 400 – 33,000 CFM• Static Pressure: 0.125 – 3"

SQI-B (BELT DRIVE)High Pressure Wheel (SQI-HP)• Wheel Sizes: 13.5 – 36.5"• Capacity: 220 – 31,000 CFM• Static Pressure: 0.25 – 5" SQI-B

SQN-B/SQN-HP

TCN-B/TCNH-B

SQN-D/SQND-EC

TCN-D/TCNH-D

SQI-D

Page 8: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-8 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

MIXED-FLOW INLINE — QMXQMXD (DIRECT DRIVE)Standard Wheel (QMXD)• Wheel Sizes: 15 – 60"• Capacity: 1,500 – 119,000 CFM• Static Pressure: 0.25 – 5"

High Pressure Wheel (QMXD-HP)• Wheel Sizes: 15 – 60"• Capacity: 1,500 – 81,000 CFM• Static Pressure: 1 – 8"

Extended Pressure Wheel (QMXD-XP)• Wheel Sizes: 15 – 60"• Capacity: 2,400 – 129,000 CFM• Static Pressure: 3 – 15"

QMX (BELT DRIVE)Standard Wheel (QMX)• Wheel Sizes: 9 – 60"• Capacity: 500 – 119,000 CFM• Static Pressure: 0.25 – 5"

High Pressure Wheel (QMX-HP)• Wheel Sizes: 9 – 60"• Capacity: 500 – 81,000 CFM• Static Pressure: 1 – 8"

Extended Pressure Wheel (QMX-XP)• Wheel Sizes: 15 – 60"• Capacity: 2,400 – 129,000 CFM• Static Pressure: 3 – 15"

CENTRIFUGAL AND CENTRI-VANE® INLINE BLOWERS (cont’d)CENTRI-VANE INLINE — CVDCVD (DIRECT DRIVE)Direct Drive• Wheel Sizes: 8 – 20"• Capacity: 80 – 5,600 CFM• Static Pressure: 0.125 – 0.875"

CVB AND CV-S (BELT DRIVE)Belt Drive (CVB)• Capacity: 600 – 23,000 CFM• Static Pressure: 0.250 – 4"• Wheel Sizes: 12 – 36"

Belt Drive Stretched Unit with Straightening Vanes (CV-S)• Capacity: 600 – 31,200 CFM• Static Pressure: 0.500 – 6"• Wheel Sizes: 12 – 36" CV-S

QMXD

QMX and QMXD are available with optional

bifurcated housing.

QMX

CVD CVB

MIXED-FLOW INLINE BLOWERS

Page 9: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-9

Revised: July 2015 • Replaces: March 2011

CENTRI-VANE ROOF MOUNTED — CVUCV (Upblast)• Wheel Sizes: 12 – 36"• Capacity: 770 – 24,000 CFM• Static Pressure: 0 – 4"• Belt Drive

CVR (Exhaust) and CVR-S (Supply)• Wheel Sizes: 12 – 36"• Capacity: 620 – 24,000 CFM• Static Pressure: 0 – 4"• Belt Drive

ROOF MOUNTED BLOWERSMIXED-FLOW ROOF MOUNTED — QMXQMXU, QMXE and QMXS are available in direct drive models and with optional bifurcated housing.QMXU (UPBLAST)Standard Wheel (QMXU)• Wheel Sizes: 9 – 60"• Capacity: 920 – 119,000 CFM• Static Pressure: 0.25 – 5"• Belt Drive

High Pressure Wheel (QMXU-HP)• Wheel Sizes: 9 – 60"• Capacity: 920 – 81,000 CFM• Static Pressure: 1 – 8"• Belt Drive

Extended Pressure Wheel (QMXU-XP)• Wheel Sizes: 15 – 60"• Capacity: 2,600 – 129,000 CFM• Static Pressure: 3 – 15"• Belt Drive

QMXE (EXHAUST) AND QMXS (SUPPLY)Standard Wheel (QMXE and QMXS)• Wheel Sizes: 9 – 30"• Capacity: 500 – 29,000 CFM• Static Pressure: 0.25 – 5"• Belt Drive

High Pressure Wheel (QMXE-HP and QMXS-HP)• Wheel Sizes: 9 – 30"• Capacity: 500 – 20,000 CFM• Static Pressure: 1 – 8"• Belt Drive

Extended Pressure Wheel (QMXE-XP and QMXS-XP)• Wheel Sizes: 15 – 30"• Capacity: 2,600 – 34,000 CFM• Static Pressure: 3 – 15"• Belt Drive

UVC CVR/CVR-S

QMXU

QMXE/QMXS

Page 10: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-10 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

EXTRUDED ALUMINUM PROP — E SERIESEUD AND EUBDirect Drive (EUD)• Prop Sizes: 24 – 48"• Capacity: 3,900 – 50,000 CFM• Static Pressure: 0 – 1.25"

Belt Drive (EUB)• Prop Sizes: 24 – 72"• Capacity: 4,300 – 94,000 CFM• Static Pressure: 0 – 1.25"

LEU (LOW SILHOUETTE)Belt Drive (LEU)• Prop Sizes: 20 – 60"• Capacity: 3,300 – 59,000 CFM• Static Pressure: 0 – 1"

LEUMO (BELT DRIVE MOTOR OUTSIDE)Belt Drive (LEUMO)• Prop Sizes: 20 – 60"• Capacity: 3,300 – 56,000 CFM• Static Pressure: 0 – 1.125"

STEEL PROP — TRITON® SERIESDirect Drive (TUD and TUDSC)• Prop Sizes: 20 – 60"• Capacity: 3,400 – 60,000 CFM• Static Pressure: 0 – 1.125"

Belt Drive (TUB and TUBSC)• Prop Sizes: 20 – 72"• Capacity: 3,600 – 92,000 CFM• Static Pressure: 0 – 1.250"

LTU (Low Silhouette Belt Drive)• Prop Sizes: 20 – 60"• Capacity: 3,300 – 73,000 CFM• Static Pressure: 0 – 1.125"

LTUMO (Belt Drive Motor Outside)LTUSC (Belt Drive Smoke Control)• Prop Sizes: 20 – 60"• Capacity: 3,300 – 69,000 CFM• Static Pressure: 0 – 1.125"

PROPELLER UPBLAST FANS AND CURBSSTEEL PROP — X.STREAM SERIESLXUL, LXUM (LOW SILHOUETTE)Low Pressure Prop (LXUL)• Capacity: 3,400 – 58,000 CFM• Belt Drive• Prop Sizes: 20 – 60"• Static Pressure: 0 – 0.625"

Medium Pressure Prop (LXUM)• Capacity: 3,400 – 48,000 CFM• Belt Drive• Prop Sizes: 20 – 60"• Static Pressure: 0 – 0.625"

LXULMO AND LXUMMO (BELT DRIVE MOTOR OUTSIDE) LXULSC AND LXUMSC (BELT DRIVE SMOKE CONTROL)Low Pressure Prop (LXULMO and LXUMMO)• Capacity: 3,800 – 55,000 CFM• Static Pressure: 0 – 0.875"• Belt Drive• Prop Sizes: 20 – 60"

Medium Pressure Prop (LXUMMO and LXUMSC)• Capacity: 3,400 – 50,000 CFM• Static Pressure: 0 – 0.625"• Belt Drive• Prop Sizes: 20 – 60"

LXUL/LXUM

TUD/TUDSC

EUD

LTU

LEU

TUB/TUBSC

EUB

LTUMO/LTUSC

LEUMO

LXULMO/LXUMMO/LXULSC/ LXUMSC

Page 11: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-11

Revised: July 2015 • Replaces: March 2011

TUBE AXIAL EXTRUDED ALUMINUM PROP — E SERIES Direct Drive (EDD)• Prop Sizes: 24 – 48"• Capacity: 1,600 – 47,000 CFM• Extruded Aluminum Propeller• Static Pressure: 0 – 1"

Belt Drive (EDB)• Prop Sizes: 24 – 60"• Capacity: 3,400 – 71,000 CFM• Extruded Aluminum Propeller• Static Pressure: 0 – 1"

TUBE AXIAL CAST ALUMINUM PROP — A SERIES Direct Drive (ADD)• Prop Sizes: 12 – 24"• Capacity: 300 – 8,100 CFM• Static Pressure: 0 – 0.5"

Belt Drive (ADB)• Prop Sizes: 16 – 48"• Capacity: 970 – 37,000 CFM• Static Pressure: 0 – 0.5"

TUBE AXIAL STEEL PROP — TRITON® SERIES Direct Drive (TID)• Prop Sizes: 20 – 60"• Capacity: 1,700 – 64,000 CFM• Static Pressure: 0 – 1"

Belt Drive (TIB)• Prop Sizes: 20 – 72"• Capacity: 2,300 – 98,000 CFM• Static Pressure: 0 – 1.25"

CURBSSTANDARD (RCG AND RCA)Galvanized (RCG)• One Piece Construction• 18 Ga. Galvanized Steel• 9.5" or 13.5" Standard Height

Aluminum (RCA)• .080 Aluminum• 9.5" or 13.5" Standard Height

ATTENUATING (RCG-AT AND RCA-AT)Galvanized (RCG-AT)• One Piece Construction• 18 Ga. Galvanized Steel• 16" or 24" Standard Height

Aluminum (RCA-AT)• .080 Aluminum• 16" or 24" Standard Height

PROPELLER UPBLAST FANS AND CURBS (cont’d)CAST ALUMINUM PROP — A SERIESDirect Drive (AUD)• Capacity: 4,000 – 35,000 CFM• Prop Sizes: 24 – 48"• Static Pressure: 0 – 0.25"

Belt Drive (AUB)• Capacity: 4,000 – 35,000 CFM• Prop Sizes: 24 – 48"• Static Pressure: 0 – 0.25"

AUD

TID

ADD

EDD

RCG/RCA

AUB

TIB

ADB

EDB

RCG-AT/RCA-AT

PROPELLER / AXIAL INLINE FANS

Page 12: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-12 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

E SERIES EXTRUDED ALUMINUM PROPExhaust (ETE)• Capacity: 1,100 – 72,000 CFM• Tiered Fan• Belt Drive• Prop Sizes: 24 – 60"• Static Pressure: 0 – 0.5"

Supply, Filtered Supply (ETS)• Capacity: 930 – 65,000 CFM• Tiered Fan• Belt Drive• Prop Sizes: 24 – 60"• Static Pressure: 0 – 0.5"

ADJUSTABLE VANE AXIAL CAST ALUMINUM AIRFOIL PROPDirect Drive (AVAD)• Capacity: 310 – 206,000 CFM• Static Pressure: 0 – 13"• Prop Sizes: 35 – 79"

Belt Drive (AVAB)• Capacity: 410 – 287,000 CFM• Static Pressure: 1 – 8"• Prop Sizes: 35 – 79"

PROPELLER / AXIAL INLINE FANS (cont’d)FIXED PITCH VANE AXIAL CAST ALUMINUM AIRFOIL PROPDirect Drive (VAD)• Prop Sizes: 18 – 60"• Capacity: 2,100 – 118,500 CFM• Static Pressure: 0 – 6"

Belt Drive (VAB and VAHB)• Prop Sizes: 12 – 60"• Capacity: Regular Duty: 680 – 99,000 CFM Heavy Duty: 670 – 115,000 CFM• Static Pressure: 1 – 6.5"

VAD

AVAD

VAB/VAHB

AVAB

AFD-C/AFDV-C

AFB-C/AFBV-C/AFB-S/AFBV-S/AFB-H/AFBV-H

FIXED TUBE AXIALDIRECT DRIVE WITH CAST ALUMINUM AIRFOIL PROPAir Distribution (AFD-C)• Capacity: 250 – 68,000 CFM• Prop Sizes: 12 – 60"• Static Pressure: 0 – 5.0"

Outlet Vane Section Air Distribution (AFDV-C)• Capacity: 380 – 68,000 CFM• Prop Sizes: 12 – 60"• Static Pressure: 0 – 5.0"

BELT DRIVE WITH CAST ALUMINUM AIRFOIL PROPAir Distribution (AFB-C)• Prop Sizes: 12 – 60"• Capacity: 10 – 99,000 CFM• Static Pressure: 0 – 6.0"

Outlet Vane Section Air Distribution (AFBV-C)• Prop Sizes: 12 – 60"• Capacity: 10 – 99,000 CFM• Static Pressure: 0 – 6.0"

BELT DRIVE WITH STAINLESS STEEL PROPStandard: Air Distribution (AFB-S)Outlet Vane Section Air Distribution (AFBV-S)High Temperature: Air Distribution (AFB-H)Outlet Vane Section Air Distribution (AFBV-H)• Prop Sizes: 12 – 36"• Capacity: 40 – 24,000 CFM• Static Pressure: 0 – 4.5"

PROPELLER ROOF FANSA SERIES CAST ALUMINUM PROPAQ (EXHAUST)Direct Drive (AQD)• Prop Sizes: 12 – 48"• Capacity: 150 – 19,000 CFM• Static Pressure: 0 – 0.75"

Belt Drive (AQB)• Prop Sizes: 24 – 48"• Capacity: 1,100 – 17,000 CFM• Static Pressure: 0 – 0.50"

SEP (REVERSIBLE)• Belt Drive• Prop Sizes: 24 – 48"• Capacity: 1,000 – 21,000 CFM• Static Pressure: 0 – 0.50"

Page 13: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-13

Revised: July 2015 • Replaces: March 2011

HOODED BELT DRIVE — “H SERIES”— HEExhaust (HEE)• Capacity: 1,500 – 54,000 CFM• E Series Extruded Aluminum

Prop• Prop Sizes: 24 – 60"• Static Pressure: 0 – 1"

Supply (HES)• Capacity: 1,100 – 58,000 CFM• E Series Extruded Aluminum

Prop• Prop Sizes: 24 – 60"• Static Pressure: 0 – 1"

Filtered (HEF)• Capacity: 1,600 – 53,000 CFM• E Series Extruded Aluminum

Prop• Prop Sizes: 24 – 60"• Static Pressure: 0 – 1"

Reversible (HER)• Capacity: 2,100 – 50,000 CFM• E Series Extruded Aluminum

Prop• Prop Sizes: 24 – 60"• Static Pressure: 0 – 1"

HOODED DIRECT DRIVE — “H SERIES” Exhaust (HEE-D)• Capacity: 1,200 – 47,000 CFM• E Series Extruded Aluminum

Prop• Prop Sizes: 20 – 54"• Static Pressure: 0 – 1"

Supply (HES-D)• Capacity: 890 – 48,000 CFM• E Series Extruded Aluminum

Prop• Prop Sizes: 20 – 54"• Static Pressure: 0 – 1"

Filtered (HEF-D)• Capacity: 1,000 – 49,000 CFM• E Series Extruded Aluminum

Prop• Prop Sizes: 20 – 54"• Static Pressure: 0 – 1"

Reversible (HER-D)• Capacity: 680 – 47,000 CFM• E Series Extruded Aluminum

Prop• Prop Sizes: 20 – 54"• Static Pressure: 0 – 1"

PROPELLER ROOF FANS (cont’d)“REBEL” STAMPED ALUMINUM PROPExhaust (REBE)• Capacity: 80 – 5,800 CFM• Static Pressure: 0 – 1"• Reversible• Direct Drive• Prop Sizes: 12 – 24"

Supply, Filtered Supply (REBS)• Capacity: 160 – 5,600 CFM• Static Pressure: 0 – 0.625"• Reversible• Direct Drive• Prop Sizes: 12 – 24"

HOODED “ECONOMIZER"Mix, Recirculate, Supply (MRS-D)• Capacity: 2,200 – 43,000 CFM• E Series Extruded Aluminum

Prop• Direct Drive• Prop Sizes: 24 – 54"• Static Pressure: 0 – 0.5"

Mix, Recirculate, Supply, Exhaust (MRSE-D)• Capacity: 1,700 – 39,000 CFM• E Series Extruded Aluminum

Prop• Direct Drive• Prop Sizes: 24 – 54"• Static Pressure: 0 – 0.5"

Mix, Recirculate, Supply-Filtered (MRSF-D)• Capacity: 2,200 – 38,000 CFM• E Series Extruded Aluminum

Prop• Direct Drive• Prop Sizes: 24 – 54"• Static Pressure: 0 – 0.5"

Page 14: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-14 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

PROPELLER ROOF FANS (cont’d)HOODED BELT DRIVE — “H SERIES” — HXExhaust (HXE)• Capacity: 1,000 – 49,000 CFM• X.Stream Steel Prop• Prop Sizes: 20 – 60"• Static Pressure: 0 – 0.75"

Supply (HXS)• Capacity: 1,100 – 54,000 CFM• X.Stream Steel Prop• Prop Sizes: 20 – 60"• Static Pressure: 0 – 0.75"

Filtered (HXF)• Capacity: 980 – 53,000 CFM• X.Stream Steel Prop• Prop Sizes: 20 – 60"• Static Pressure: 0 – 0.75"

CENTRIFUGAL UTILITY VENT SETSModels with an “S" have a welded, Lorenized™, steel wheel with backward inclined flat blades.Models with an “A" have a welded aluminum wheel with backward inclined flat blades.Models with a “V" have an aluminum wheel with backward inclined flat blades.Models with an “F" have a steel wheel with forward curved blades.Models ending with “-A" have a backward inclined airfoil wheel.

UTILITY VENT SET — CPBELT DRIVESteel Wheel and Scroll (CPS)Aluminum Wheel and Scroll (CPA)• Capacity: 70 – 49,000 CFM• Static Pressure: 1 – 8"• Class I or Class II (size 120 – 365)• Wheel Sizes: 10 – 49"

Aluminum Wheel and Steel Scroll (CPV)• Capacity: 50 – 43,000 CFM• Static Pressure: 0.25 – 2.5"• Wheel Sizes: 10 – 49"

Steel Wheel and Scroll (CPS-A)• Capacity: 660 – 78,000 CFM• Wheel Sizes: 12 – 49"• Static Pressure: 1 – 8"• Class I or Class II (size 120 – 365)

Aluminum Wheel and Scroll (CPA-A)• Capacity: 700 – 53,000 CFM• Wheel Sizes: 12 – 49"• Static Pressure: 1 – 8"• Class I or Class II (size 120 – 365)

Steel Wheel and Scroll (CPFB)• Wheel Sizes: 10 – 30"• Capacity: 500 – 25,000 CFM• Static Pressure: 0.125 – 2"

DIRECT DRIVE:Aluminum Wheel and Steel Scroll (CPFD)• Wheel Sizes: 6 – 12"• Capacity: 200 – 2,600 CFM• Static Pressure: 0.125 – 2"

FIBERGLASS UTILITY VENT SETFCP• Wheel Sizes: 12 – 36"• Capacity: 800 – 32,000 CFM• Static Pressure: 1 – 10"• Arrangement 10, Class II Construction

Page 15: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-15

Revised: July 2015 • Replaces: March 2011

WITH 4 DISCHARGE POSITIONSCA-4 DWDI• Capacity: 900 – 261,000 CFM• Belt Drive• Wheel Sizes: 12 – 73"• Static Pressure: 1 – 12"• Arrangement 3 & 7• Class I, Class II or Class III

INDUSTRIAL BLOWERS, PLUG AND PLENUM FANSCF blowers have a steel, centrifugal, backward inclined, flat blade wheel. They are available in single wide configurations.CA blowers have a steel, centrifugal, backward inclined, airfoil wheel. They are available in single and double wide configurations.CAF-DW blowers have a steel, centrifugal, backward inclined, airfoil wheel. They are available in double wide configurations.

SINGLE WIDTH SINGLE INLET — CA/CFWITH 7 DISCHARGE POSITIONSAirfoil Wheel (CA SWSI)• Capacity: 700 – 209,000 CFM• Belt Drive• Wheel Sizes: 12 – 73"• Static Pressure: 1 – 12"• Arrangements: 1, 3, 7, 8, 9 & 10• Class I, Class II or Class III

Flat Blade Wheel (CF SWSI)• Capacity: 950 – 198,000 CFM• Belt Drive• Wheel Sizes: 12 – 73"• Static Pressure: 1 – 12"• Arrangements: 1, 3, 7, 8, 9 & 10• Class I, Class II or Class III

WITH 4 DISCHARGE POSITIONSAirfoil Wheel (CA-4 SWSI)• Capacity: 490 – 141,000 CFM• Belt Drive• Wheel Sizes: 12 – 60"• Static Pressure: 1 – 12"• Arrangements: 1, 2, 3, 4 & 7• Class I, Class II or Class III

Flat Blade Wheel (CF-4 SWSI)• Capacity: 510 – 127,000 CFM• Belt Drive• Wheel Sizes: 12 – 60"• Static Pressure: 1 – 12"• Arrangements: 1, 2, 3, 4 & 7• Class I, Class II or Class III

DOUBLE WIDTH DOUBLE INLETWITH 7 DISCHARGE POSITIONSIndustrial (CA DWDI)• Capacity: 900 – 375,000 CFM• Belt Drive• Wheel Sizes: 12 – 73"• Static Pressure: 1 – 12"• Arrangement 3 & 7• Class I, Class II or Class III

Commercial (CAF-DW)• Capacity: 900 – 375,000 CFM• Belt Drive• Wheel Sizes: 12 – 73"• Static Pressure: 1 – 12"• Arrangement 3 & 7• Class I, Class II or Class III

CA DWDI CAF-DW

Page 16: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-16 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

PLENUM FANS — PLCBelt Drive (PLC)Direct Drive (PLC-D)• Capacity: 900 – 192,000 CFM• Wheel Sizes: 12 – 73"• Static Pressure: 1 – 12"• Aluminum and Steel Construction• Arrangements: 1, 3, & 4• Class I, II, & III

INDUSTRIAL BLOWERS, PLUG AND PLENUM FANS (cont’d)MATERIAL-LADEN AIR HANDLERS — MHOpen Type Impeller (MH)• Belt Drive Capacity:

300 – 60,000 CFM• Wheel Sizes: 7 – 29"• Static Pressure: 1 – 27"• Arrangements: 1, 4, 8, 9 & 10

Backplated Type Impeller (MHB)• Belt Drive Capacity:

250 – 65,000 CFM• Wheel Sizes: 7 – 29"• Static Pressure: 1 – 27"• Arrangements: 1, 4, 8, 9 & 10

Backward Inclined, Flatblade Impeller (MHA)• Belt Drive Capacity:

250 – 56,000 CFM• Direct Drive Capacity:

350 – 145,000 CFM• Wheel Sizes: 7 – 29"• Static Pressure: 1 – 27"• Arrangements: 1, 4, 8, 9 & 10

Reinforced Open Type Impeller (MHR)• Belt Drive Capacity:

300 – 60,000 CFM• Wheel Sizes: 7 – 29"• Static Pressure: 1 – 27"• Arrangements: 1, 4, 8, 9 & 100

MH MHB

MHR MHA

PLUG FANS — CCPTrue Airfoil Wheel (CCP-A)• Capacity: 800 – 59,000 CFM• Wheel Sizes: 12 – 44.5"• Static Pressure: 1 – 6"• Class I & II

Backward Inclined Wheel (CCP-F)• Capacity: 1,000 – 59,000 CFM• Wheel Sizes: 12 – 44.5"• Static Pressure: 1 – 6"• Class I & II

Page 17: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-17

Revised: July 2015 • Replaces: March 2011

POWER-PLUME®— PP• Patent pending• Powered induction device lab exhaust system• Fan mounted, stack mounted or curb mounted

LAB EXHAUST CURB — LEC• Minimum 12 Ga. Phenolic Epoxy• Powder Coated Steel• Continuously Welded Corner• 12" or 18" Standard Height

DIRECT DRIVERegular (QMXDVP)• Capacity: 2,500 – 120,000 CFM• Wheel Sizes: 15 – 60"• Static Pressure: 1 – 4"

High Pressure (QMXHPDVP)• Capacity: 2,500 – 110,000 CFM• Wheel Sizes: 16.5 – 60"• Static Pressure: 1 – 4"

BELT DRIVERegular (QMXVP)• Capacity: 2,500 – 120,000 CFM• Wheel Sizes: 9 – 60"• Static Pressure: 1 – 6"

High Pressure (QMXVP)• Capacity: 2,500 – 108,000 CFM• Wheel Sizes: 9 – 60"• Static Pressure: 1 – 6"

VARI-PLUME®Patent #7,484,929CA-VP• Capacity: 1,500 – 147,000 CFM• Belt Drive• Wheel Sizes: 12 – 73"• Static Pressure: 1 – 12"

DIRECT DRIVERegular (QMXLE)• Capacity: 1,500 – 79,000 CFM• Wheel Sizes: 15 – 49"• Static Pressure: 0.25 – 5"

High Pressure Wheel (QMXLE-HP)• Capacity: 1,500 – 54,000 CFM• Wheel Sizes: 15 – 49"• Static Pressure: 1 – 8"

BELT DRIVERegular (QMXLE)• Capacity: 500 – 79,000 CFM• Wheel Sizes: 9 – 49"• Static Pressure: 0.25 – 5"

High Pressure (QMXLE-HP)• Capacity: 500 – 54,000 CFM• Wheel Sizes: 9 – 49"• Static Pressure: 1 – 8"

LAB EXHAUST SYSTEMSLE SERIESTCNHB-LE• Capacity: 350 – 49,000 CFM• Belt Drive• Wheel Sizes: 10 – 49"• Static Pressure: 0.5 – 4"

CPS-LE• Capacity: 70 – 12,000 CFM• Belt Drive• Wheel Sizes: 6 – 24.5"• Static Pressure: 1 – 5"

TCNHB-LE

CPS-LE

Page 18: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-18 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

GRAVITY VENTILATIONSPUN ALUMINUMRegular (PR)• Intake Capacity:

260 – 22,000 CFM• Relief Capacity:

220 – 22,000 CFM• Sizes: 8 – 48"

Tiered (TR)• Intake Capacity:

260 – 22,000 CFM• Relief Capacity:

220 – 22,000 CFM• Sizes: 8 – 48"

DIRECT FIRE HEATED MAKEUP — ERVBelt Drive (HMD)• Capacity: 700 – 4,100 CFM• Static Pressure: 0 – 3"• Max. Temperature Rise: 1000°F

ENERGY RECOVERY — ERVAvailable with optional heating and cooling coils.Direct Drive (ERV-D)• Capacity: 30 – 1,300 CFM• Energy Recovery Wheel Sizes:

18 – 24"• Static Pressure: 0 – 1.5"

Belt Drive (ERV-B)• Capacity: 500 – 10,000 CFM• Energy Recovery Wheel Sizes:

28 – 72"• Static Pressure: 0 – 1.5"

FORWARD CURVED FILTERED KITCHEN SUPPLY — KSPDirect Drive (KSPD)• Capacity: 80 – 1,800 CFM• Wheel Sizes: 4.75 – 8.5"• Static Pressure: 0 – 0.75"

Belt Drive (KSPB)• Capacity: 200 – 12,000 CFM• Wheel Sizes: 9 – 20"• Static Pressure: 0 – 1.75"

SUPPLY, ENERGY RECOVERY, MAKEUP, AND GRAVITY FORWARD CURVED SUPPLY — ASPRegular (ASP), Tiered (ASP-T)• Bottom or Side Discharge• Capacity: 280 – 16,000 CFM• Belt Drive• Wheel Sizes: 9 – 20"• Static Pressure: 0 – 2"

High Wind Rated (ASPTH)• Bottom Discharge• Capacity: 280 – 16,000 CFM• Belt Drive• Wheel Sizes: 9 – 20"• Static Pressure: 0 – 2"

BACKWARD INCLINED FILTERED SUPPLY — CFS• Capacity: 1,100 – 53,000 CFM• Wheel Sizes: 12 – 36.5"• Static Pressure: 1 – 5"

ASP-TASPTH

ASP

TRPR

Page 19: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™ www.eccosupply.ca 12-19

Revised: July 2015 • Replaces: March 2011

MOUNTABLE MINI-BLOWER FAN HEADSCAC-MBDY• Capacity: 5,000 – 7,800 CFM• Direct Drive• Wheel Size: 24 & 30"• Velocity: 120 – 710 feet per minute, at 10 – 40 feet

MOUNTED BLOWER FAN HEADSCAC-UTE• Capacity: 3,200 – 4,600 CFM• Direct Drive• Wheel Size: 18"• Velocity: 100 – 500 feet per minute, at 10 – 40 feet

AIR CIRCULATOR FAN HEADS — CACCAC-ACH and CAC-ACHO (Oscillating)• Capacity: 5,000 – 7,900 CFM• Direct Drive• Wheel Size: 24 & 30"• Velocity: 120 – 720 feet per

minute, at 40 – 10 feet

CAC-IHPWD (Wash down)• Capacity: 7,100 – 9,300 CFM• Direct Drive• Wheel Size: 20 – 30"• Velocity: 420 – 1,700 feet per

minute, at 40 – 10 feet

SUPPLY, ENERGY RECOVERY, MAKEUP, AND GRAVITY (cont’d)GRAVITY VENTILATION (cont’d)EXTRUDED TIEREDRegular (TRE), High Wind Rated (TREH)• Throat Sizes: 12 × 12 – 60 × 120"• Intake Capacity: 330 – 63,000 CFM• Relief Capacity: 310 – 56,000 CFM

Intake (GI)• Intake Capacity: 600 – 93,000 CFM• Throat Sizes: 12 × 12 – 72 × 144"

Relief (GR)• Relief Capacity: 900 – 86,000 CFM• Throat Sizes: 12 × 12 – 72 × 144"

LSUG (Low Silhouette)Sizes: 24 – 60"

AIR CIRCULATOR FANS

Mounting accessories sold

separately.

Mounting accessories sold separately.

Pedestal

TREHTRE

GI/GR

LSUG

2 Mounting Choices:

Wall

3 Mounting Choices:

Blower Wall

I-beam

Ceiling

Page 20: - ECCO Supplyeccosupply.ca/pdf/price-lists/12. Ventilation Products/Cook Fans.pdf · COOK FANS  ... “GEMINI” ROOM EXHAUSTS — GC AND GN ... A SERIES CAST ALUMINUM PROP

COOK FANSwww.lorencook.com

– E.&O.E. – All Prices F.O.B. Our Warehouse – Subject to Change Without Notice – All Taxes Extra – May not be Available at All Branches –

ECCO Supply™12-20 www.eccosupply.ca

Revised: July 2015 • Replaces: March 2011

PORTABLE BLOWERSCAC-PBD (Direct drive, three blade prop)• Capacity: 9,000 – 15,000 CFM• Wheel size: 36 & 42"• Velocity: 130 – 820 feet per

minute, at 50 – 10 feet

CAC-PBB (Belt drive, four blade prop)• Capacity: 14,000 – 22,000 CFM• Wheel size: 36 – 48"• Velocity: 130 – 820 feet per

minute, at 70 – 10 feet

AIR CIRCULATOR FANS (cont’d)SUSPENDABLE BLOWERCAC-SBD• Capacity: 9,000 – 16,800 CFM• Direct Drive• Wheel Size: 36 & 42"• Velocity: 130 – 820 feet per minute, at 10 – 50 feet

CAC PBBCAC PBD