2
All Purpose Radiographic System MILLENNIUM MILLENNIUM SEDECAL Pelaya, 13 - Polígono industrial “Rio de Janeiro” 28110 - Algete (Madrid - SPAIN) Central Offices: Factory: Tel.: (34) 91-628 0544 / 91-628 1592 Tel.: (34) 91-629 0721 Fax: (34) 902 190 385 Fax: (34) 91-629 0783 Email: [email protected] Email: [email protected] SEDECAL USA Inc 2910 N Arlington Heights Rd. Arlington Heights, Illinois 60004 USA Tel.: 1 (847) 394 - 6960 Fax: 1 (847) 394 - 6966 Email: [email protected] Bucky Table Elevating Bucky Table Millen_Rev. 1.2_10_08

diptico b - MPS X-RayTitle: diptico b Created Date: 10/24/2008 4:07:55 PM

  • Upload
    others

  • View
    1

  • Download
    0

Embed Size (px)

Citation preview

Page 1: diptico b - MPS X-RayTitle: diptico b Created Date: 10/24/2008 4:07:55 PM

All Purpose Radiographic System

MILLENNIUM

MILLENNIUM

SEDECALPelaya, 13 - Polígono industrial “Rio de Janeiro”28110 - Algete (Madrid - SPAIN)Central Offices: Factory:Tel.: (34) 91-628 0544 / 91-628 1592 Tel.: (34) 91-629 0721Fax: (34) 902 190 385 Fax: (34) 91-629 0783Email: [email protected] Email: [email protected]

SEDECAL USA Inc2910 N Arlington Heights Rd.Arlington Heights, Illinois 60004USATel.: 1 (847) 394 - 6960Fax: 1 (847) 394 - 6966Email: [email protected]

Bucky Table

Elevating Bucky Table

Mill

en_R

ev. 1

.2_1

0_08

Page 2: diptico b - MPS X-RayTitle: diptico b Created Date: 10/24/2008 4:07:55 PM

TOMOGRAPHY FEATURE (optional)

With the tomography version and adjustableheight table top it is possible to make highquality linear tomographic exposures.

To switch over to tomography, the couplingdevice on the tube carrier arm has to beattached to the connecting rod on thetomography unit.

When making oblique X-ray exposures, theradiation beam axis remains precisely posi-tioned at the centre of the film.

The MILLENNIUM tubestand can easily beturned and moved providing very convenientadjustments for lateral exposures.

A counter-balanced tube stand provides a smoothvertical movement. For exposures with the buckystand, the tube column can be moved beyond thetable either on the right or left-hand side. On eitherside, the vertical range of movement of the tubeassembly provides a minimum source-to-floor distanceof only 40 cm.

LARGE PATIENT POSITIONING RANGEThe “floating” table-top has a very largerange of longitudinal and transversal move-ments. By pressing the foot switches, theelectromagnetic brakes are released for alldirections.All radiographic accessories (lateral cassetteholder, compression band, etc.) can bequickly and safely attached to the table top.

The Bucky tray, which can be operated with one hand, has a wide longitudinalmovement in addition to the large scope of table top movement. The integratedautomatic exposure control (optional) permits exposures of high image qualityand prevents incorrect exposures.

FAST AND SAFE PATIENT POSITIONINGThe minimum height of the elevating table allowseasy and fast positioning on table-top for any kindof patient: child, elderly or handicapped.

By pressing one button, the operator can locklateral and longitudinal table - top motion - a lightwill alert the user that the movement is locked.

A safety anticollision system during downwardmovement of the table avoids accidents when anobject is encountered in its path.

Elevating Bucky Table