16
© Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

Embed Size (px)

Citation preview

Page 1: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© C

opyr

ight

200

4 A

BB

Pow

er T

echn

olog

ies

All

right

s re

serv

ed. -

1 -

Distribution Automation Product News

Tyler Kerner & Fahrudin Mekic

Page 2: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

2 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

AgendaDistribution

Products

New Products to be Launched Distribution Products

Communication Products

Micro 1E™ Products

Arc Protection Products

Motor Protection Products

FT Family Products

Page 3: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

3 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

HIF Detect™ downed conductor detection Most powerful and fastest product on the

market (>160 MHz) Advanced Boolean logic Four zones step phase distance Operator control interface (OCI) standard Substation battery monitoring DPU2000R protection standard SA-2+ functionality standard DNP3.0 Level 2+ standard IRIG-B time synchronization standard Dual rated power supply (48/125) Wire-alike with DPU2000R

REF 550 FeaturesHigh-range Distribution

AvailableNow

Page 4: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

4 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

HIF Testing ResultsHigh-range Distribution

HIF Detect™ downed conductor tests

ONCOR, TX – January 2004

City of Homestead, FL – April 2004

Wisconsin Public Service, WI – June 2004

ONCOR, TX – September 2004 15 detects on 18 drops

Independence Power & Light, MO – October 2004

First Energy, OH – December 6-7, 2004

City of Loveland – January 2005

Kansas City Board of Public Utilities - 2005

Page 5: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

5 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

Substation Automation 2 Plus (SA-2+) for Southern California Edison (SCE) Enhanced programmable logic Expanded operator control interface

(OCI) function Improved fault targeting Ethernet Modbus (10FL) SNTP time synchronization

Advanced logic for Sacramento Municipal Utility District (SMUD) Lamp test and target reset logic

Cost Reductions

DPU2000R EnhancementsMid-range

Distribution

AvailableNow

Page 6: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

6 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

DNP3.0 Level 2+ option DNP3.0 Level 2 certified

Individual point mapping

Analog dead-banding

Report by exception

Ethernet Modbus for DPU/TPU2000R 10FL fiber / 10/100 MB copper

SNTP time synchronization

Access Fault records, operations records, waveform records via web browser

Field Upgrade kits available

WinECP Ethernet compatibility

Communication AdvantagesAutomation

Communications

AvailableNow

Page 7: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

7 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

REF 610 FeaturesBasic-range Distribution

Application Basic overcurrent protection

Low cost backup

Basic Protection Functions Overcurrent Protection

Breaker Failure

Reclosing – 3 shot

Trip Circuit Supervision

Arc Protection (Optional)

Remote Connectivity DNP 3.0

Modbus RTU/ASCII (Electrical-RS485 and Fiber Optic)

Sequence of Events Recording

Wireless Front Communication

AvailableNow

Page 8: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

8 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

Evolution in Distribution ProtectionDistribution

Products

(Latin America)

Page 9: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

9 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

REM 610 FeaturesBasic Motor Protection

Application Medium sized asynchronous motors

Back up protection for synchronous motors

Basic Protection Functions Overcurrent Protection

Thermal Overlaod

Breaker Failure

RTD’s and Thermistor

Remote Connectivity Modbus RTU/ASCII (Electrical-RS485 and Fiber

Optic)

Excel-based setting calculation tool available

Wireless Front Communication

Sequence of Events Recording

AvailableNow

Page 10: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

10 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

REM 610 Multimedia CDBasic Motor Protection

AvailableNow

Page 11: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

11 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

REA 10X – Arc ProtectionArc Protection

AvailableNow

Unique, maintenance free fiber-optic technology for arc detection The fiber serves as a sensor throughout

its length

Solutions allowing extension and expansion

A regular pulse monitors sensor fiber condition

Fast trip time (< 2.5 ms) with semi-conductor outputs

Arc supervised by three phase O/C

Circuit-breaker failure protection

Selective tripping by extension units

Installation video available

Page 12: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

12 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

REA 10X – Multimedia CDArc Protection

Page 13: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

13 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

FT Family Enhancements in a nutshellTest

Equipment

FT-1 10 pole switch Nameplates and customer labels Clear, black or colored covers

FT-14 14 Pole Switch

FT-19R Extended unit terminals for 19” rack Multiple switches rack mounted

FT-19RS Special assemblies allowing for meter

and lockout switches on panel

Page 14: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

14 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

Advanced overcurrent, voltage and frequency protection for distribution feeders

Independent Breaker Failure

Programmable Logic

Breaker maintenance – operations, failure, slow, interrupted kA

Full power system metering (A, V, W, Vars, WHrs, VarHrs, pf, f)

Fault and event recorders

Waveform capture

WinECP Windows software tool

Micro 1E™ Product Features - REF 544NMicro 1E Products

AvailableNow

Page 15: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

15 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

Advanced overcurrent, voltage and frequency machine (motor and generator) protection

Programmable Logic Breaker maintenance – operations, failure,

slow, interrupted kA Full power system metering (A, V, W, Vars,

WHrs, VarHrs, pf, f) Fault and event recorders Waveform capture GPUECP Windows software tool

Micro 1E™ Product Features - REM 544NMicro 1E Products

AvailableNow

Page 16: © Copyright 2004 ABB Power Technologies All rights reserved. - 1 - Distribution Automation Product News Tyler Kerner & Fahrudin Mekic

© 2

004

AB

B P

ower

Tec

hnol

ogie

s -

16 -

2004

/10/

13 –

OE

M20

04_D

istr

ibut

ionA

utom

atio

n.pp

t – B

A P

TM

V

Advanced differential and overcurrent 2-, 3-Wdg transformer protection

Programmable Logic Breaker maintenance – operations, failure,

slow, interrupted kA Full power system metering (A, V, W, Vars,

WHrs, VarHrs, pf, f) Fault and event recorders Waveform capture WinECP Windows software tool

Micro 1E™ Product Features - RET 544NMicro 1E Products

AvailableNow