7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
1/14
Building Pathology and
Diagnostic
Building Pathology and diagnostic
Homework 3
Homework 4
Serkan cakIr
736742
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
2/14
Building Pathology and
Diagnostic
This Building is located close to
the central station.There is a police
station at the opposite side.The
building is located between two
buldings.
Central Station
Via Giovanni Schiparelli
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
3/14
Building Pathology and
Diagnostic
Front Side of building looked
in direction of Nort-east)
Backside of building looked
in direction of South-west)
As the building having 4 floor,the
first floor is used as commercial.The
rest ones are used as residential .
On the facade of frontside ,there
are some anomalies as seen fromthe picture(Loss of
Mass,Scaling,Encrustration...This
front facade is subjected to lots
anomalies in comparison with back
side.
As seen from the picture,this facadeis quite seen in good
condition.Because of the facade
seeing the closed area of which is
not affected with weathering as
much as opposite site of facade.
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
4/14
Building Pathology and
Diagnostic
Front Elevation
Survey
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
5/14
Building Pathology and
Diagnostic
Front Elevation
Survey
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
6/14
Building Pathology and
Diagnostic
Backside Elevation
Survey
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
7/14
Building Pathology and
Diagnostic
Backside Elevation
Survey
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
8/14
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
9/14
Building Pathology and
Diagnostic
1) Loss of Mass
a)Crumbling
Crumbling is the loss of internal coherence and loss of material.
As you see from the pictures taken from surface,some crumbling
effects are severly than rest of them.This anomaly depends
upon also where it happens.According to the pictures,thecrumbling formed on the upper part of facade is subjected to
medium effect,but instead the crumbling formed on the first
floor subjected to severely effect.The most affected part could
have been subjected to more water effects(rain..), or by the
action of human effects..
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
10/14
Building Pathology and
Diagnostic
b)Scaling
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
11/14
Building Pathology and
Diagnostic
1) Loss of Mass
a)Scaling
Scaling is local flaking or peeling away of the near-surface
portion of hardened concerete or mortar.The reason to make
scaling occur could be freeze-thaw attack or salt attack.From the
pictures shown on the previous page one part is especiallyundergone much suffering.Maybe the problem could be
enlightened analyzing that wall in depth.
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
12/14
Building Pathology and
Diagnostic
2)Chromatic/Texture Alteration
Deposit
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
13/14
7/27/2019 _ Building Pathology and Diagnostic - Homework 3 y 4
14/14
Building Pathology and
Diagnostic
Freeze&
Thaw
Salt
Attack
Salt
Exposure
Rain
Not to be
compliance with
the design rules to
product concrete
High W.C
ratio
Capilarity
Action
Indirect
Action
GroundWater
Having
unsuccifient
Drenaige system
Early
Finishing
Failure
Alteration
Process
Defect&
Action
Error/
Omission
A
A
Cylic
Deformation
Water Exposure
Scaling
Quality of
Concrete
Quality of
Concrete
Bounced
water
From
the air
Through
fromthe rain
Direct
Action