CPE Installation
Copyright Alvarion Ltd.
1Objectives
Upon completion of this module students will know the following: CPE installation
Installation procedure Indoor installation Outdoor installation Outdoor installation Grounding issues
2Installation examples
Routing of Cat 5 Cable Routing of Cat 5 Cable
Ver. 09-04-15
IDU and AC PowerIDU and AC PowerODU Wall Mounted ODU Pole
Mounted
3Recommended tools
DescriptionTool "M3M8
Spanners
Flat Screwdriver 5.0 X 100Flat Screwdriver 5.0 X 100For N-type Connectors (Antenna Connector)RJ-45 Connector (CPE, IDU-ODU)
Crimpers
Cable Stripping ToolCutter, Knife, Scissors, Etc.Cutting Tools Cutter, Knife, Scissors, Etc.Cutting Tools
MaterialsPlastic Cable Tie For Outdoor Use. Minimum Width: 4.8 MmMinimum Thickness: 1.3 Mm
Strips
Any Material For Isolation. Must Be Waterproof And Resistant ToTemperature Change (-40C To 60C)
Isolation Material
RJ-45 Connectors ShieldedConnectorsCategory 5E Ethernet Cable (8-wire, 24 AWG)Eth. Cable
Measurement ToolsFor Testing The Cables With CAT5 ConnectorsFor Testing Category 5E Ethernet Cable (8-wire, 24 AWG)
Cable Tester
4Grounding
Any CPE ODU must be installed with proper grounding Any CPE installation must have proper earth grounding at
customer home premises, so IDU relays on good grounding from electrical company
The AC should be tested and approved by our customer Avoid floating ground
Ver. 09-04-15
5Grounding
Ver. 09-04-15
6Preparing the ODU
Ver. 09-04-15
For more detailed information please refer to the CPE installation manual - chapter 5
7Mounting kits
Pole mounting kit is provided with the unit The two pairs of threaded holes on the back of
the unit are enabling vertical and horizontal polarization
Use the washer then lock the nut Optional Tilt Mounting kit is available
Provides 15tilt range
Ver. 09-04-15
Provides 15tilt range Attached to the ODU and then to a pole
8ODU Polarization
Vertical Polarization
For vertical polarization install the unit with Polarization arrow pointing UP
For horizontal polarization install the unit with Polarization arrow pointing RIGHT
Ver. 09-04-15
Horizontal Polarization
9Connecting the antenna cable
Connect the right angle N-Type male connector of the coaxial RF cable to the antenna.
Connect the other end of the RF cable to the N-Type connector (marked ) located on the bottom panel of the unit
Fix the antenna cable onto the pole using a cable strip. Use additional cable strips to route the cable
such that water can accumulate on the cable
Ver. 09-04-15
such that water can accumulate on the cable bends, away from the unit.
When routing the cable, do not exceed the minimum bending radius in the cable specifications.
The RF connectors should be properly sealed to protect against rain and moisture
For more detailed information please refer to the CPE installation manual Chapter 6
Sealing ODU connectors
10SU IDU-ODU CAT5e Cable
SU IDU-ODU CAT5e Cable Indoor to outdoor Category 5 Ethernet cable with two
shielded RJ-45 connectors is used in order to connect the CPE unit to the outdoor
The length of the Ethernet cable connecting the CPE to the user's equipment, together with the length of the Indoor-to-Outdoor cable, should not exceed 100
Ver. 09-04-15
1 2 3 4 5 6 7 8
1 + 24 + 5
7 + 8
3 + 6
Indoor-to-Outdoor cable, should not exceed 100 meters/328 feet
In case of an external antenna installation, an additional RF cable with N-type connectors will be connected from the SU RF connector marked with to the antenna
The Indoor-to-Outdoor cable provides pin-to-pin connection on both ends
All eight pins are in use The drawing shows the wire pair connections required
for the Indoor-to-Outdoor cable
11SU IDU-ODU CAT5e Cable
Wire Color Pin Number Usage
SU IDU-ODU CAT5e Cable The color codes used in cables supplied by Alvarion with crimped
connectors are as follows :
Ver. 09-04-15
Blue 1 TXBlue/White 2 TX RTN
Orange 3 RXOrange/White 6 RX RTN
Brown 4 - 55 VDC RTNBrown/White 5 - 55 VDC RTN
Green 7 - 55 VDCGreen/White 8 - 55 VDC
12Subscriber Unit IDU Installation
The unit can be placed on a desktop, rack or wall-mounted Drilling template included with the unit Assemble an RJ-45 connector with a protective cover Connect the IDU-ODU cable to the RADIO connector
Ver. 09-04-15
Connect the power cord to the units AC socket Verify that the POWER LED is lit Configure the basic parameters and align the antenna Connect the 10/100 Base-T ETHERNET connector to the data equipment Crossed Ethernet if connecting to a Hub/Switch Straight cable if connecting directly to a PC Network Interface Card
13Subscriber Antenna Alignment
DescriptionLED NumbersWireless link is up
Point the antenna towards the general direction of the Base Station Verify that at least one LED (LED 2) of the LINK QUALITY bar display is on,
indicated that the unit is synchronized with the AU Rotate the antenna until the maximum Link Quality reading is achieved Verify that the power indication of the unit is On
Ver. 09-04-15
Wireless link is upSU is connected with and receives services from AU (Network Entry
completed) 1
5 dB SNR < 10 dBUp to 210 dB SNR < 15 dBUp to 315 dB SNR < 20 dBUp to 420 dB SNR < 24 dBUp to 5
SNR 24 and RSSI < -75Up to 6SNR 24 and RSSI -75Up to 7SNR 24 and RSSI -70Up to 8SNR 24 and RSSI -60Up to 9RSSI -20 (saturation)Up to 10
14Antenna Alignment
SU Alignment Unit (SAU) Connect the unit to the CPE Use the LEDs to determine the
functionality and link quality of the CPE
Ver. 09-04-15
Seal the SAU connector For more detailed information please refer to the CPE installation manual Chapter 8
15SU Si Installation
Connect the Power
Verify that the Status LED is lit orange
If a detached antenna is used
Remove the cap on the top expose the RF connector
Connect to it the RF cable
Ver. 09-04-15
Install the antenna (as described in the following slides) Connect to it the other end of the RF cable
Fasten the antenna connector using the torque key
Connect the 10/100 Base-T ETHERNET connector to the data equipment
Crossed Ethernet if connecting to a hub/switch
Straight cable if connecting directly to a PC Network Interface Card (NIC)
Verify that the Ethernet Integrity Green LED is illuminating
Torque key
16SU Si Installation
External antenna wall mount with pan capability - Indoor Installation Attach the suctions cups to the antenna
Place the antenna on the glass
the antenna connector should point downwards
press the suction cups onto the glass
Ver. 09-04-15
press the suction cups onto the glass
Connect the antenna cable to the antenna connector
Fasten the antenna connector using the torque key
Rotate the antenna left or right so the domed surface of the antenna is perpendicular to the direction of the Base Station
Check the Signal LEDs to ensure the antenna is aligned