© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
FETTE ABSOLUT Filter systemFETTE ABSOLUT Filter system
For production processes in chemical and pharmaceutical industries
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Reason for development ofnew containment technologiesReason for development ofnew containment technologies
The rise of the usage of potent compounds within the pharma industry worldwide
The awareness of the dangers created by cross contamination and personnel safety
The general industrial dust filters applied in the pharmaceutical industry today
Result:Creating the missing link to meet the latest requirements in hygienic pharmaceutical production processes
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Disassembly Conventional HEPA filter units manufactured for the nuclear industry
Highest possible requirements in regard to: Efficiencies
Containment
Origin of the new filter system for production linesOrigin of the new filter system for production lines
For manual handling of hazardous products in chemical and pharmaceutical industry
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Laminar Flow Ceilings Personnel
Floodgate
FETTE Absolut fields of productionFETTE Absolut fields of production
Dust Filtration
Glove-Boxes
Isolators
Gasab-sobtion
Ventilation
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Product overviewProduct overview
To protect the product
size and version according requirements
Recirculation series / ventilation series
• Horizontal series • Vertical series
Machine room:•Basic •Standard Pharmaceutical production room areas:•Pharma •GMP
Positive pressure isolators
Personnel floodgateUnit series
Residual dust load0,0001mg/m³
Air capacity300 - 64.000 m³/unit
Residual dust load0,0001mg/m³
Air capacity300 – 33.000 m³/h/unit
Two stage HEPA filter unit non dedustabel
Two stage dedustable HEPA filter unit
To protect personnel and production rooms/size and version according requirements
Size and construction according requirements
Efficiency Acc. specificationAir capacity300 – 16.000 m³/h/unit
Residual dust load0,1 - 0,0001mg/m³
Air capacity300 – 64.000 m³/unit
Residual dust load0,1 mg/ m³
Air capacity300 – 33.000 m³/h/unit
Negative pressure isolators
Laminar Flow CeilingsCassette-constructionSingle stage HEPA filterunits non dedustable
Single stage dedustable HEPA filter units
Glove-Boxes/Isolators
Laminar Flow Ceilings / Personnel Floodgate
GasadsorbtionVentilationDust filtration
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Dust filtration and recovery of high dust loads from production machines such as:
Fluid bed dryers
Tablet presses
Capsule filling machines
Tablet coaters
Tablet filling machines etc.
Application of the new filter systemApplication of the new filter system
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
General surveyGeneral survey
GMP series for production rooms
Single module unit
Application : Dust recovery from tablet presses
Features:
2 stage HEPA filter unit
Integrated glove box
Scanning device
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
GMP series for production rooms
Multiple module unit
Application : Dust recovery from tablet presses
Features:
2 stage HEPA filter unit
Integrated glove box
Tablet for filter stage
General surveyGeneral survey
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Standard series for machine rooms
Single module unit
Application : Dust recovery from tablet presses
Features:
2 stage HEPA filter unit
Reinforced body for application in explosion areas
General surveyGeneral survey
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
DOPDOP
Measuring of efficiency
Typical Laser-Particle Counter
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Take away the servicing door
Filter ChangeFilter Change
Pull out the inner plastic bag, which is always part of the unit
Lower the sealed filter cassette for take out
1 2 3
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Pull the cassette out into the existing plastic bag
Filter ChangeFilter Change
Heat sealing of the cassette twice to cut the bag in between
In the end the used and sealed filter cassette is ready for disposal
4 5 6
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
The Operator pulls the can to the front, in order to seal it, inside the isolator
Dust recoveryDust recovery
He puts a lid onto the inner plastic bag
1 2
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
The operator puts the can to the side in order to pull the closed inner bag out
Dust recoveryDust recovery
3 4
As a further step he pulls the inner bag out through a LaCalhene valve into the outer bag
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
The door is closed from inside to be able to undock the alpha port (outer port)
Dust recoveryDust recovery
The outer alpha port is being undocked by turning
The double sealed product now is ready for take away in a safest possible way
5 6 7
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
Weighing of recovered productWeighing of recovered product
The operator, according to the efficiency measurement of the cassettes, gets a printout for documentation of the recovered product
© All rights reserved by Fette GmbH, also in case of pending patens. All uses, e.g. like copying or disclosure to third parties, strictly restricted to us.
TargetsTargets
Our targets are to close the gap in hygienic pharmaceutical production processes by providing:
Lowest possible
OELs
Highest possible
filter efficiencies