24
© ABB Group June 23, 2022 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

Embed Size (px)

Citation preview

Page 1: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 1

AquaProbeCustomer Presentation

BU Measurement Products – Electromagnetic Flow

Page 2: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 2

AquaProbe Product launch presentation Introduction

There is no new water on Earth - all the water there ever will be is already here

*The monetary value of Non revenue Water is estimated to be valued at over $18 billion per year

Water production and treatment companies globally are major consumers of energy

Accurate measurement of water is becoming increasingly important:

Future abundant supply of water cannot be guaranteed

Increased pressures caused by rising populations

*Global Water Intelligence, Water Technology Markets 2010

Page 3: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 3

AquaProbe Package

AquaProbe has become the insertion type portable flowmeter of choice, setting the industry standard and being found in demanding applications everywhere

It is the acknowledged, accurate and economic alternative to full bore metering

AquaProbe now works with WaterMaster transmitter and is known as AquaProbe FEA100

AquaProbe also works with AquaMaster 3 transmitter where it is known as AquaProbe FEA200, extending the choice of power supply options from traditional mains and battery power to renewable energy options

Page 4: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 4

AquaProbe basic concept

Insertion Type Flowmeter

Rugged & Robust Construction

‘Hot Tap’ Capability

Good Accuracy over Wide Flow Range

Price Virtually Independent of Pipe Size

Suitable for Permanent or Temporary Installations

No Moving Parts – High Reliability

Choice of Transmitters and Power Supply Options

Page 5: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 5

AquaProbe Specification

Suitable for pipe diameters from 200mm to 8000mm

Accuracy ±2% of Measured Velocity (or ±2mm/sec) whichever is greater

Bi-Directional

For Clean Water Only

Page 6: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 6

Product positioning

The two versions of the AquaProbe are positioned as two separate products

Many water applications today are in large lines and require accurate measuring devices to monitor water usage. The AquaProbe family provides a cost effective alternative to full-bore meters, as well as an option to perform surveys on existing lines and meters

With the flexibility that both AquaProbe models provide for temporary and permanent installations, this insertion probe flowmeter is a valuable addition to ABB’s comprehensive line of flow measurement products

Tongai Mutongo
Change photo using current AP terminal box
Page 7: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 7

Product positioning

The AquaProbe FEA100 is more suited to permanent installations, because it is primarily a mains operated unit

It is a robust and cost effective flowmeter that is especially well-suited to large pipe diameters

With 4 -20mA, Profibus DP v1 and HART communication outputs as options, the AquaProbe can easily be integrated with other existing instruments

Page 8: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 8

Product positioning

The AquaProbe FEA200 is far more suited to operate as a temporary flowmeter, because of its battery powered option facilitates it’s use as a field monitoring device

With the built in logging function, the unit can be installed in series with an existing flowmeter to monitor the flowmeter over a period of time

The built in logging function allows flow and pressure data to be collected for analysis and evaluation. The option of transmitting data via SMS, removes the need to visit the unit regularly.

Page 9: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 9

AquaProbe FEA200 can be remotely located and is capable of sending data anywhere & anytime

AquaProbe FEA200 has 3 power modes based on specific customer requirements:

Mains-powered with SuperCap back-up

Battery-powered

External renewable (solar/wind) energy with SuperCap back-up

AquaProbe FEA200 with mains power offers built-in rechargeable Super Capacitor power source

Operation for up to 5 days without power (dependent on operating conditions), with no batteries to replace

Continuous SMS operation

In the event of mains interruption, continuous measurement is maintained and alarms reported via SMS protocols

To help you sellAquaProbe FEA200 – mains power

Page 10: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 10

AquaProbe FEA200 battery powered option offers a choice of battery options

Battery only – external manganese alkaline battery pack

0°C to 45°C (32 to 113°F)

Typical 5 year battery life

Battery only – external lithium battery pack

+45°C ambient temperatures & option of a 10 year battery life

Smooth battery replacement

AquaProbe FEA200 sustains the logger (for minutes) before logger data contents are lost enabling smooth switchover

No loss of logger data during battery replacement

Provided ‘SuperCap’ capacitor is still charged

To help you sellAquaProbe FEA200 – battery power, no data loss

Page 11: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 11

AquaProbe FEA200 renewable option offers access to solar and wind energy source with a simple DC (6-21V) connection from panel or generator

No external rechargeable batteries required

No external regulators

Very simple installation

The availability of a rechargeable ‘SuperCap’ permits direct connection of solar power and other renewable power source to transmitter

The ‘SuperCap’ powers the transmitter during the night or during lack of power for up to 3 weeks (dependant on operating conditions)

To help you sellAquaProbe FEA200 – renewable energy (solar / wind)

Page 12: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 12

AquaProbe FEA200 solar powered option offers access to free, clean and inexhaustible energy source with a simple DC (6-21V) connection from solar panel or generator

No external rechargeable batteries required

No external regulators

Very simple installation

The rechargeable ‘SuperCap’ permits direct connection of solar power and other renewable power sources to the transmitter

The ‘SuperCap’ powers the transmitter during the night or during a power interruption for up to 3 weeks (dependant on operating conditions)

To help you sellAquaProbe FEA200 – wind power

Page 13: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 13

To help you sellAquaProbe FEA100/ FEA200

‘Hot tap’ capability so that it can be installed quickly, easily and conveniently, without interrupting the water supply. The meter can initially be installed via a hot tap system, under full working pressure conditions, without the need to shut down the system. Thereafter the meter can be inserted & removed under pressure

Ease of Operation fitting to existing pipelines without the need for the major, expensive and time consuming excavations or alterations associated with full bore meters. The ability of the AquaProbe to be installed in remote locations with its battery power supply makes it simple to install in the most arduous of environments

Page 14: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 14

To help you sellAquaProbe FEA100/ FEA200

‘Unrivalled on Accuracy. The accuracy and consistency of measurement of the AquaProbe is why it’s the insertion flowmeter of choice for many water and waste water companies

At +/- 2% of Rate, which can be maintained for years without the need for recalibration, the meter exhibits exemplary accuracy over a wide operating flow range in both forward and reverse directions. This means that it is highly versatile instrument, both for peak daytime and low night time flow rates

Speed, ease & security in the field, Sensor Memory eliminates the need to match sensor and transmitter in the field. Self configuration sequence eases start-up

Page 15: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 15

To help you sellAquaProbe FEA100/ FEA200

True Choice of Power Source.

What could be better than having the flexibility to use mains, battery or renewable energy, depending on the choice of transmitter.

A choice of power options ranging from battery power with a ten year life

For an installation in remote locations where an external supply would be problematic

Through to mains power with SuperCap backup

Page 16: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 16

To help you sellAquaProbe FEA100/ FEA200

AquaProbe coding

AquaProbe is specified using new product codes in line with ABB common coding

AquaProbe will be coded as FEA and the transmitter will either be FEA100 For AquaProbe with WaterMaster transmitter or

FEA200 for AquaProbe with AquaMaster 3 transmitter

Below is an extract of how coding appears

AquaProbe FEA100

AquaProbe FEA200

Page 17: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 17

Features and BenefitsAquaProbe FEA200

On Board Remote Communications Package with SMS

AquaProbe FEA200 is available with a multichannel, multivariable logger that can record both flow and pressure via a direct digital transfer of data, thereby ensuring optimum accuracy and resolution of measurement.

Coupled with remote communication via SMS, allows the AquaProbe to be installed in very remote locations and to send data back via Quad band GSM/SMS from the field to the customer, either on a daily basis, or on demand

Page 18: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 18

Features and BenefitsAquaProbe FEA200

Pressure Transducer option available

AquaProbe can also return pressure information, from a secondary pressure transducer which is available from ABB

The customer can survey the pressure in a line and can be used for zonal surveying and leak detection.

With a pressure drop over time, it is very likely that there is a leak in the pipeline

Page 19: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 19

Features and Benefits AquaProbe – integrated solution

Integrated single package solution AquaProbe FEA200 has all 3-in-1:

AquaMaster 3 transmitter DataLogger SMS

Communication options* AquaProbe offers a choice of Quad

band GSM/SMS communication protocols

Modbus RS485 Profibus DP v1 HART 4-20mA RS232

NOTE: GSM/SMS, RS485 & Scanreader are mutually exclusive options

Page 20: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 20

Features and BenefitsAquaProbe – Long life, flexible transmitter

Powerful and flexible transmitter

AquaProbe FEA200 has an IP68 (NEMA 6P) transmitter for continuous submersion (not with integral GSM/SMS Aerial)

Features a stainless steel housing with a thermoplastic outer and the assembly is sealed-for-life to IP68 as standard

Plug & socket connections for all inputs and outputs

Simplified Operation, Maintenance & Training

HMI provides common user experience

Intuitive navigation and “Easy Setup” configuration eliminates need for intensive training and

Reduces cost of ownership

Page 21: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 21

Features and Benefits AquaProbe FEA100 Leading the way

NAMUR-compliant diagnostics

AquaProbe FEA100 has the ability to self-diagnose while the process is running

DSP for maximum reliability

Advanced ‘Digital Signal Processing’ gives improved performance and enables real-time measurements separating the real signal from the noise, providing high quality outputs especially in harsh environments

Page 22: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 22

Features and BenefitsAquaProbe FEA100/200

A 3 year warranty as standard on every AquaProbe sensor ensures customers can choose AquaProbe with complete confidence

Page 23: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 23

Conclusion

With the addition of these fantastic and market leading new features to its existing flexible and proven performance, AquaProbe really is the insertion probe of choice

With the new AquaProbe, the best of breed insertion type portable flowmeter has been made better still

This innovative clean water measurement solution takes the many qualities that the industry has come to rely on and builds upon them to deliver unrivalled high return on investment combined with low cost of ownership

Page 24: © ABB Group May 20, 2015 | Slide 1 AquaProbe Customer Presentation BU Measurement Products – Electromagnetic Flow

© ABB Group April 18, 2023 | Slide 24