Why HyperVOC The main question asked regarding MPPT solar controllers is “How many panels can I hook up in series?” Since we designed the OutBack MX60 a decade ago, we have answered this question thousands of times! This is the scenario: Consumer: I have a 150V MPPT controller. How many panels can I put in series. I plan on using a panel with a VOC of 44.3V. Technician: How cold does it get where you live? Consumer: I live in Alberta, Canada. It gets mighty cold up here, Aye, -32 0 C in winter. Technician: The panels will output higher voltages in cold weather. The NEC says you must multiply the VOC of your solar panel by the correction factor based on your coldest conditions. In your case the correction factor is 1.23. Let’s see what happens when we apply the 1.23 correction factor to 2 and 3 panels in series. Two in series looks like this: 44.3V x 2 x 1.23 = 108.98V. Three in series looks like this: 43.3 x 3 x 1.23 = 163.46V. On a normal 150V controller you can put 2 panels in series. The highest volt- age the controller will see is 108.98V. That is below the 150V max input volt- age. If you put 3 panels in series on a standard 150V controller, it will see up to 163.46V on a cold morning. I suggest you read the directions and warranty information on your controller. Go to the section of the instructions for your normal (other than MidNite) controller that deals with PV input voltage. It will read something like this regarding voltages above 150V. “Voltage above 150VDC will cause the controller to explode into a huge ball of flames leaving a smoldering crater. This condition is not covered under warranty.” I might have paraphrased a bit but you get the message, they do not want you going over 150VDC on the input. Here is a little known fact about PV output volt- age and charge controllers. -32 o C MidNite Solar Inc www.midnitesolar.com -3 32 2 2 2 o o o o C C C C Page 1

32 -32 C oC MidNite Solar Inc · PDF fileWhy HyperVOC The main question asked regarding MPPT solar controllers is “How many panels can I hook up in series?” Since we

  • Upload
    lenhi

  • View
    216

  • Download
    2

Embed Size (px)

Citation preview

Page 1: 32 -32 C   oC MidNite Solar Inc · PDF fileWhy HyperVOC The main question asked regarding MPPT solar controllers is “How many panels can I hook up in series?” Since we

Why HyperVOC

The main question asked regarding MPPT solar controllers is “How many panels can I hook up in series?” Since we designed the OutBack MX60 a decade ago, we have answered this question thousands of times!

This is the scenario:Consumer:

I have a 150V MPPT controller. How many panels can I put in series. I plan on using a panel with a VOC of 44.3V.

Technician:

How cold does it get where you live?

Consumer:I live in Alberta, Canada. It gets mighty cold up here, Aye, -320C in winter.

Technician:

The panels will output higher voltages in cold weather. The NEC says you must multiply the VOC of your solar panel by the correction factor based on your coldest conditions. In your case the correction factor is 1.23. Let’s see what happens when we apply the 1.23 correction factor to 2 and 3 panels in series. Two in series looks like this: 44.3V x 2 x 1.23 = 108.98V. Three in series looks like this: 43.3 x 3 x 1.23 = 163.46V.

On a normal 150V controller you can put 2 panels in series. The highest volt-age the controller will see is 108.98V. That is below the 150V max input volt-age. If you put 3 panels in series on a standard 150V controller, it will see up to 163.46V on a cold morning. I suggest you read the directions and warranty information on your controller. Go to the section of the instructions for your normal (other than MidNite) controller that deals with PV input voltage. It will read something like this regarding voltages above 150V. “Voltage above 150VDC will cause the controller to explode into a huge ball of flames leaving a smoldering crater. This condition is not covered under warranty.”

I might have paraphrased a bit but you get the message, they do not want you going over 150VDC on the input. Here is a little known fact about PV output volt-age and charge controllers.

-32oC MidNite Solar Incwww.midnitesolar.com-332222ooooCCCC

Page 1

Page 2: 32 -32 C   oC MidNite Solar Inc · PDF fileWhy HyperVOC The main question asked regarding MPPT solar controllers is “How many panels can I hook up in series?” Since we

On cold mornings the PV panels will put out full voltage even before you can see the sun. Ambient light may not have much current behind it but it does have voltage exceeding the possible voltage limits that destroy the controller. The fact that there is no power behind the output voltage means that the controller will not be able to turn on and drag the panels down from VOC to max power voltage.

The controller requires a few watts of power coming in from the PV panels to overcome its internal power requirements. While the controller is waiting for enough power to wake up, the PV array is at its highest output voltage. This is very dangerous if the maximum operating voltage is exceeded.

The MidNite Solar controller gives you bonus headroom for those cold mornings that would potentially destroy any other controller. We have advised thousands of custom-ers to play it safe in conditions like our example above. MidNite has a unique character-istic of the circuitry that allows it to go beyond the maximum operating voltage for these conditions, it’s called HyperVOC.

Do not abuse the HyperVOC zone though. For example, let’s take a 150V Classic config-ured with 4 modules in series that have 36.9 VOC, 4 x 36.9 = 147.6. In Alberta with a -320C temperature, the max VOC will reach 181.54. This is well within the HyperVOC zone on a 48V battery bank.

Wake up

Output Current

PV Voltage

Output CurrenOutput CurreneeerrruuuCCCuuuuuupppuuuOOOOOO

www.midnitesolar.com

Max Input Voltage

Non-Operative HyperVOC Zone

Temp: -32oCOUTPUT

CURRENT

0 Amps

20 Amps

40 Amps

60 Amps

80 Amps

100 Amps

4 AM 5 AM 6 AM 7 AM 8 AM 9 AM

PV VOLTAGE

25V

0V

50V

75V

100V

125V

150V

175V

200V

Classic 150 Wake-up VOC

8

uueeeeeeegeeegeeagagtataoltloltVoVVoVVVVVVPVPVPVPPP eeeeggaattooVVVVVVPPP

ww

eeggagagtataololVoVot Vt VututpupunpnpInInx xaxaxMaMaMM eeggaallooVVttuuppnnxxaaMM

4 AM 5 AM 6

5VV

0VV

0VV

5VV

0VV

5VV

0VV

rrraaatttiiivvveee HHHyyyyypppppeeerrrVVVOOOCCC ative HyperVOCyypp CCCCOOOOVVVVrrrreeeeppppppppyyyyyyyyHHHHeee evvvviiiitttteeerrrerpppppeeepeppOOOpppppOpppOOOOnnn-nooonnnonNNNoooNoNNNN rrrreeeeppppppppOOOO-nnnnooooNNNN ZZZooonnneeeZoneeeeennnnooooZZZZ

ttttt

0

2

4

6

AM 9 AM

upuppppppp

Page 2

Page 3: 32 -32 C   oC MidNite Solar Inc · PDF fileWhy HyperVOC The main question asked regarding MPPT solar controllers is “How many panels can I hook up in series?” Since we

HyperVOC Charts for the Classics 150 and 200

Classic 150 HyperVOC Chartwww.midnitesolar.com

0.0V

150V

198V

Nor

mal

Ope

ratin

g R

ange

Hyp

erV

OC

Ran

ge

Normal 150VRange

Non

-Ope

ratio

nal

Rang

e

48V & Above

174V 24V Battery Bank

162V 12V Battery Bank

Classic 200 HyperVOC Chartwww.midnitesolar.com

0.0V

200V

248V

Nor

mal

Ope

ratin

g R

ange

Hyp

erV

OC

Ran

ge

Normal 200VRange

Non

-Ope

ratio

nal

Rang

e

48V & Above

224V 24V Battery Bank

212V 12V Battery Bank

You would think that this is a well-designed system, WRONG! This configuration will be safe from exploding into a ball of flames, but the VOC is so high, chances are the panels may not warm up enough during the day to drop below 150V. Remember the Classic will not turn on when the PV input voltage is above 150V. Since the nominal 25OC VOC was already 147.6V, you can see it won’t take much cold weather to go over 150V. Heck you probably wouldn’t even need a sweater, but your system will not be charging due to cold temperature.

The charts below display the upper maximum HyperVOC limit based on the nominal battery bank voltage. Important: HyperVOC is the maximum input voltage plus nominal battery voltage. The maxi-mum nominal battery bank voltage allowable is 48V, even if the battery bank being used is higher than 48V.

Page 3

Page 4: 32 -32 C   oC MidNite Solar Inc · PDF fileWhy HyperVOC The main question asked regarding MPPT solar controllers is “How many panels can I hook up in series?” Since we

HyperVOC Charts for the Classics 250

17722 67th Ave NEArlington, WA 98223Ph 360.403.7207Fax 360.691.6862www.midnitesolar.com

Classic 250 HyperVOC Chartwww.midnitesolar.com

0.0V

250V

298V

Nor

mal

Ope

ratin

g R

ange

Hyp

erV

OC

Ran

ge

Normal 250VRange

Non

-Ope

ratio

nal

Rang

e

48V & Above

274V 24V Battery Bank

262V 12V Battery Bank

24 to 2019 to 1514 to 10

9 to 54 to 0

-1 to -5-6 to -10

-11 to -15-16 to -20-21 to -25-26 to -30-31 to -35-36 to -40

1.021.041.061.081.101.121.141.161.181.201.211.231.25

AmbientTemp (OC)

Correction Factors for Ambient Temperatures Below 25OC(77OF). (Multiply the rated open circuit voltage by the

appropriate correction factor shown below.)

Table 690.7 Voltage Correction Factors for Crystalline andMulticrystalline Silicon Modules

AmbientTemp (OF)

Factor

76 to 6867 to 5958 to 5049 to 4140 to 3231 to 2322 to 1413 to 54 to -4

-5 to -13-14 to -22-23 to 31-32 to -40