© 2011 IBM Corporation
Storwize V7000
© 2011 IBM Corporation
IBM Storage Systems
2
The Storwize V7000 uses basic storage units called managed disks and collects them into one or more storage pools
These storage pools then provide the physical capacity to create volumes for use by hosts
Volumes
Storage Pool
Managed Disks (MDisks)
Logical Building Blocks
© 2011 IBM Corporation
IBM Storage Systems
3
Managed Disks
The basic unit of storage in the Storwize V7000 is the managed disk or MDisk for short
A managed disk must be protected by RAID to prevent loss of the entire storage pool
In Storwize V7000 we can have two different types:– Internal Array MDisk
• The internal RAID implementation inside the system takes drives and builds a RAID array with protection against drive failures
– External SAN attached MDisk• An external storage system provides the RAID function and presents
a Logical Unit (LU) to the Storwize V7000
© 2011 IBM Corporation
IBM Storage Systems
4
Storage Pool A storage pool is a collection of managed disks
The primary property of a storage pool is the extent size which by default using the GUI is 256MB– This extent size is the smallest unit of allocation from the pool
When you add managed disks to a pool they should have similar performance characteristics:– Same RAID level – Roughly the same number of drives per array– Same drive type (SAS, NL SAS, SSD except if using Easy Tier)– Similar performance characteristics for external storage system
MDisks
This is because data from each volume will be spread across all MDisks in the pool, so the volume will perform approximately at the speed of the slowest MDisk in the pool– The exception to this rule is that if using Easy Tier you can have 2
different tiers of storage in the same pool – but the MDisks within the tiers should still have the same performance characteristics
© 2011 IBM Corporation
IBM Storage Systems
5
Whenever you create a new volume you must pick a single storage pool to provide the physical capacity
By default the created volume will stripe all of it’s data across all the managed disks in the storage pool as shown on the left diagram
Thin provisioned volumes consume extents only as actual data is written to disk
A2
A6
B1
B5
A3
A7
B2
B6
A4
A8
B3
B7
A1
A5
A9
B4
B8
A1 A2 A3 A4 A5 A6 A7 A8
B1 B2 B3 B4 B5 B6 B7 B8
A9 Volume A
Volume B
Volumes
Managed Disks
Volumes
Thin ProvisionedVolume CC1 C2 C3 C4 C5 C6 C7 C8
C1
Storage Pool
© 2011 IBM Corporation
IBM Storage Systems
What is the Storwize V7000 Physically the Storwize V7000 system is
comprised of…
One Control Enclosure containing...– Two node canisters– Two PSUs (Power Supply Units) – 24 x 2.5” disk drives or 12 x 3.5” disk drives
Optionally up to nine Expansion Enclosures per one controller enclosure, containing...– Two expansion canisters– Two PSUs (Power Supply Units) – 24 x 2.5” disk drives or 12 x 3.5” disk drives
These expansion enclosures may be freely inter-mixed in a single storage system
Disk drives: – 15 K RPM SAS– 10 K RPM SAS– SSD– Nearline
Clusters of up to 4 Control Enclosures / 8 nodes
6
© 2011 IBM Corporation
IBM Storage Systems
Canister Details
7
Node Canister– Intel CPU running at 2.1GHz– 32GB internal flash drive– 8GB Cache – Four 2/4/8 Gbps Fibre Channel ports
• Usage optional, for external storage and/or for server attachment
– Two USB 2.0 ports
– Two 10/100/1000 Mbps Ethernet ports • Port 1 usage required • Port 2 usage optional
– Two 6 Gbps SAS ports • Usage optional for expansion enclosures
– The four ports on the bottom right will be blanked out• May be used in the future
Expansion Canister
Two 6 Gbps SAS ports– Usage of port 1 is mandatory– Use of port 2 is optional for
adding additional expansion enclosures
© 2011 IBM Corporation
IBM Storage Systems
Control Enclosure Rear View2076-112/124
Expansion Enclosure Rear View2076-212/224
SAS Ports and Cabling
8
© 2011 IBM Corporation
IBM Storage Systems
SAS Ports and Cabling
© 2011 IBM Corporation
IBM Storage Systems
Storwize V7000 Advanced Functions Thin Provisioning – Included
– Allows for storage optimization by consuming real capacity only when data is written
FlashCopy – Included– Allows use of FlashCopy function with internal Storwize V7000 volumes as
well as external storage under Storwize V7000 management– FlashCopy Manager optionally available to help manage
Easy Tier – Included– Allows for management of hotspots automatically by migrating extents
from spinning drives to solid state drives as needed for higher performance– TPC for Disk Midrange Edition optionally available to help manage
Metro and/or Global Mirror – Optional– Allows you to replicate data synchronously or asynchronously between
Storwize V7000 systems– TPC for Replication optionally available to help manage
External Virtualization – Optional– Allows you to bring external fibre channel disk systems under Storwize
V7000 control providing access to all the functions of the virtualization software
© 2011 IBM Corporation
IBM Storage Systems
11
Easy Tier SSDs (Solid State Drives)
– Very high performance but expensive per GB– To get the most value from SSD investment it is
important to use SSDs efficiently
Although Volumes that require higher performance can be identified, in general only a portion of a Volume really requires or benefits from the extra performance that an SSD provides– It is desirable then to have only a portion of the Volume
reside on the SSD freeing up the space on the SSD that is “wasted” on this Volume for other Volumes to utilize
© 2011 IBM Corporation
IBM Storage Systems
Easy Tier
Initial implementation will have two tiers:– generic SSD which is tier 0– generic HDD which is tier 1
Internal MDisks will have tier chosen automatically
External MDisks will have tier assigned by the user– Will default to generic HDD
Easy Tier is designed to work with either Storwize V7000 internal SSDs or SAN based external SSDs
12
© 2011 IBM Corporation
IBM Storage Systems
13
Easy Tier – STAT Summary Output
© 2011 IBM Corporation
IBM Storage Systems
14
Easy Tier – Volume Heatmap View
© 2011 IBM Corporation
IBM Storage Systems
15
Data Migration by Volume and Sub-Volume
SSD Storage Pool HDD Storage Pool
Hybrid Storage Pool (SSD & HDD)
Easy TierEnabled in Hybrid Pool
Existing Volume Based Data Migration
Easy Tier Automated Data Migration
© 2011 IBM Corporation
IBM Storage Systems
16
Easy Tier – Automated Data RelocationHost Volume Hybrid Storage Pool
MDisk from SSD Array
MDisks from HDD Arrays
Extent Virtualization
Hot Extents Migrate Up
Cold Extents Migrate Down
© 2011 IBM Corporation
IBM Storage Systems
17
Internal Storage – RAID
The Storwize V7000 setup will contain a number of internal drive objects, but these drives cannot be directly added to storage pools
The drives need to be included in a Redundant Array of Independent Disks (RAID) to provide protection against the failure of individual drives
Storwize V7000 will support the following RAID levels:– RAID 0 (striping, no redundancy)– RAID 1 (mirroring between 2 drives)– RAID 5 (striping, can survive one drive fault)– RAID 6 (striping, can survive two drive faults)– RAID 10 (RAID 0 on top of RAID 1)
© 2010 IBM Corporation© 2010 IBM Corporation
© 2011 IBM Corporation
IBM Storage Systems
18
RAID Setup
One click GUI RAID setup
A one click GUI setup exists to configure all drives into RAID arrays– Automatically create spares and optimize for capacity – meaning utilize
all drives
Select preset Select the drive class
Select the preset from the list shown– The list provided will depend upon the drive class selected
Decide whether to create spares
Choose the creation policy– Optimize for performance or capacity
Chose the number of drives to provision
© 2011 IBM Corporation
IBM Storage Systems
19
Visual task flow guidance
Integrated videoinstruction
System statusalways available
Systemrecommendations
Link to more information if
needed
Fresh New User InterfaceBased on the well-received XIV interface
© 2011 IBM Corporation
IBM Storage Systems
20
New Easy-to-Use User Interface
20
Browser-based can be accessed from any platform
Relevant visuals One click Presets available to
simplify administration Advanced options available
along with full CLI control Easier navigation between
screens guides users to next step
See command-lines that are being executed when you perform actions in the UI
Provision a volume in as few as six clicks; setup system in as few as ten clicks
© 2011 IBM Corporation
IBM Storage Systems
Storwize Command Line Interface (CLI)
A flexible tool for system management
Setup of CLI for Storwize on windows– Generate encryption keys– Establish secure connection
© 2011 IBM Corporation
IBM Storage Systems
22
Presets “Templates” of commonly used and recommended input
parameters for:– RAID Array Creation– Volume Creation– FlashCopy Creation
Only applicable on create– Preset defaults can be overridden using advanced settings
option in GUI or changed after creation via the GUI or CLI• Example: Mirrored volume preset is chosen with default
sync rate of 2MB/s and to increase use GUI or CLI to change to something higher
© 2011 IBM Corporation
IBM Storage Systems
VIOS
VIOS
IBM i
Storwize V7000 Connection to IBM i
Managed Disks
Volumes in SVC (Virtual Disks)
Storage Pools
Hdisks in VIOS
VTSCSI
IBM i disk drivesvscsi
FC conneciton
© 2011 IBM Corporation
IBM Storage Systems
Recommeded configuration for IBM iBased on best practice with IBM i and midrange storage
146 GB 15 K RPM disk drives
300 GB 15 K RPM disk drives
General recommendation is RAID-10–Recommended RAID level depends on the workload
characteristics
Create Vdisks in stripped mode
Extent size 256 MB
Size of LIUNs: 70 GB or 140 GB
Multipath with 2 * VIOS
Sufficient respources in VIOS
Check that Queue-depth in VIOS is set to 32 or higher
© 2011 IBM Corporation
IBM Storage Systems
PowerHA SystemMirror for i and SVC / V7000
© 2011 IBM Corporation
IBM Storage Systems
Screenshots of Storwize configuration for IBM i