© 2009 Cemtek Environmental, Inc.
NewProduct
andTechnologyOverview
CEMTEK Environmental Inc.3041 S. Orange Ave.Santa Ana, CA 92707
800-400-0200www.cemteks.com
a technical solution tomeet every need…
© 2009 Cemtek Environmental, Inc.
Mercury Particulate Tunable Diode Laser
Ammonia Slip Monitoring Compliance Process Control/Feedback
HCl Monitoring CEMTEK Instruments
Combustion Optimization Products
What’s New?
© 2009 Cemtek Environmental, Inc.
Regulations, where do we stand? Since vacating the Clean Air Mercury Rule
(CAMR), the implementation of mercury monitoring has primarily fallen on the state and local regulators.
The EPA often uses Consent Decrees to mandate mercury monitoring.
The cement industry is currently under review by the EPA to slash mercury emissions.
Mercury
© 2009 Cemtek Environmental, Inc.
Detection Technologies Continuous Monitoring
Cold Vapor Atomic Fluorescence
Example: Thermo Freedom Mercury Series
Continuous Batch Measurement
Pre-Concentration on Gold Filter, Thermal Desorbtion, Atomic Fluorescence
Example: Tekran Series 3300
Long Term Batch Measurement
Sorbent Trap or Appendix K
Example: Apex Instruments
Mercury
© 2009 Cemtek Environmental, Inc.
The Mercury Freedom System
• Dilution based measurement
• Inertial Filter Sample Conditioning
• Conversion at the Stack
• Direct Measurement CVAF
• High sensitivity
• True real-time monitoring
• Modular design
• iSeries platform
Thermo Environmental
© 2009 Cemtek Environmental, Inc.
Model 80i Hg Analyzer Direct Measurement CVAF
Continuous measurement
No additional gasses required
Diluted Sample Lower moisture, less reactive
Speciating Measures either HgT or Hg0
Analyzer Detection Limit: Currently ~1 ng/m3 (~0.1 ppt)
No cross interference with SO2
Thermo Environmental
© 2009 Cemtek Environmental, Inc.
IIaa
KKff
Hg + hHg + h (254 nm)(254 nm) Hg* Hg*
Hg* Hg* Hg + h Hg + h (254 nm)(254 nm)
IIa a == IIoo[I-e[I-e-{ax(Hg)}-{ax(Hg)}]]
IIff I Iooax(Hg) orax(Hg) or
K (Hg)K (Hg)
High Intensity Hg Lamp
Reflective Filtering
Enhanced Light Baffling
Bandpass Filter
Hg Fluorescence
LAMP
SUPPLY
ELECTRONICS
PHOTO MULTIPLIER
TUBE
SAMPLE OUT
SAMPLE IN
Thermo Environmental
© 2009 Cemtek Environmental, Inc.
Series 3300 CMMS Components
Model 3320 Sample ConditionerModel 3320 Sample ConditionerModel 3330 Inertial ProbeModel 3330 Inertial Probe
Model 3310 Calibration UnitModel 3310 Calibration UnitModel 2537A AF Model 2537A AF AnalyzerAnalyzer
Tekran Instruments
© 2009 Cemtek Environmental, Inc.
Principles of Operation
Mercury in sample gas is pre-concentrated onto (pat’d) pure gold cartridge
Adsorbed mercury is thermally desorbed Detected by atomic fluorescence detector Two cartridges are used to alternately sample and
desorb allowing continuous operation No gaps in data stream
Tekran Instruments
© 2009 Cemtek Environmental, Inc.
HGP Dual Trap Sampling Probe
Configuration:• Heated Sample Probe –Dual Probe
Heaters• Length (4,6,9,12ft Standard)
• Material –C276 Hastelloy or 316 SS • Enclosure – Insulated SS Junction Box
• Trap Sizes – 10mm Large Standard• Optional 6mm Small Trap Adapter
• Paired trap holders• Pitot Tube – Optional S Type Pitot
Configuration:• Heated Sample Probe –Dual Probe
Heaters• Length (4,6,9,12ft Standard)
• Material –C276 Hastelloy or 316 SS • Enclosure – Insulated SS Junction Box
• Trap Sizes – 10mm Large Standard• Optional 6mm Small Trap Adapter
• Paired trap holders• Pitot Tube – Optional S Type Pitot
(shown with optional pitot)
Apex Instruments
© 2009 Cemtek Environmental, Inc.
Sorbent Trap
Apex Instruments
Configuration:• Section 1: Sample Collection Section• Section 2: Breakthrough Indicator Section• Section 3: Vapor-Spike Section to
Measure Recovery
Configuration:• Section 1: Sample Collection Section• Section 2: Breakthrough Indicator Section• Section 3: Vapor-Spike Section to
Measure Recovery
© 2009 Cemtek Environmental, Inc.
Wet FGD Scrubber Particulate Monitoring Saturated stack applications Opacity monitors cannot transmit light
through saturated stack
Example: Sick FEW 200 Particulate Monitor
Particulate
© 2009 Cemtek Environmental, Inc.
What are Tunable Diode Lasers?
Small crystals of Ga, As, Sb, P Similar to those used in telecommunications, CD
players, and laser printers Emits laser radiation when an electric current is
applied Laser center wavelength depends on composition
of crystal Wavelength can be changed over a narrow range
by changing current, or over a wider range by changing laser operating temperature
Permits scanning over entire absorption feature
Tunable Diode Lasers
© 2009 Cemtek Environmental, Inc.
Emission Wavelength
Absorption region
Side wavelengths, without absorption
Ab
sorb
ance
I = Ioe-cl I = Ioe-cl
IR Spectroscopy
Tunable Diode Lasers
© 2009 Cemtek Environmental, Inc.
Practical Applications for the TDL
SCR/SNCR Ammonia Slip Monitoring Compliance
Single Point Monitor Internal Audit Cell
Daily span checks meet regulatory requirements
Process Control/Feedback Multi-point arrays with single analyzer Multiplexed signal allows for multiple
monitoring points in dust laden processes Useful for SCR tuning and monitoring catalyst
bed degradation over time
Tunable Diode Lasers
© 2009 Cemtek Environmental, Inc.
Practical Applications for the TDL
HCl Monitoring Waste-to-Energy Applications
Plastics in fuel stock form HCl during combustion process
Wood-fired Boiler Applications Logs transported to lumber mill Cogen and
Power plant facilities can absorb salt (NaCl) when in contact with salt water during transport and form HCl during combustion process
Tunable Diode Lasers
© 2009 Cemtek Environmental, Inc.
Interaction Between NH3 and HCl
Detached Plume Phenomenon which occurs from the formation of
ammonia salts due to the cooling of NH3 and HCl
Tunable Diode Lasers
NH3 + HCl → NH4CL
© 2009 Cemtek Environmental, Inc.
Combustion Optimization Products
Insitu O2
Cross Duct CO Single Pass Opacity Dual Pass Opacity Close-Coupled NOX/O2
Combustion Optimization
© 2009 Cemtek Environmental, Inc.
NOX Contributing FactorsAreas for Reduction of Excess Air
OverfireAir
Flow
Fuel/ A ir CarbonMonoxide
CO
Carbonin Ash
ExcessOxygen
BoilerLoad
BurnerLevels
I n-Service
SteamTem perature
RH/ SH
W allSootblow ing
FurnaceW all
Cleanliness
SteamTem perature
RH/ SH
W allSootblow ing
BurnerTilt
Position
BulkFlam e
Tem perature
NOxEm ission
Level
Combustion Optimization
© 2009 Cemtek Environmental, Inc.
MODEL 2000 CROSS DUCT CO MONITOR
CEMTEK Instruments Model 2000
Cross Duct Carbon Monoxide Monitor
© 2009 Cemtek Environmental, Inc.
IR OPTICAL/GFC
CEMTEK Instruments Model 2000
Cross Duct Carbon Monoxide Monitor
© 2009 Cemtek Environmental, Inc.
TRANSMITTER
CEMTEK Instruments Model 2000
Cross Duct Carbon Monoxide Monitor
© 2009 Cemtek Environmental, Inc.
CEMTEK Instruments Model 2000
RECEIVER
Cross Duct Carbon Monoxide Monitor
© 2009 Cemtek Environmental, Inc.
NON-COMPLIANT OPACITY PROCESS MONITOR
CEMTEK Instruments Model 6000 & 6010
© 2009 Cemtek Environmental, Inc.
Many Plants have multiple Boiler configurations feeding into a main stack. Individual Boiler outlets allows for the determination of any emissions violation at the source.
Multi-Unit applications can utilize non compliant opacity monitors to detect individual excursions seen as an overall increase with the Stack Monitor. Accurate measurement of individual boiler opacity may avoid any excursion over the permitted limit imposed on the plant since detection at the onset of incomplete combustion. Energy reduction measures are incrementally reduced as the opacity stays below a preset threshold.
CEMTEK Instruments Model 6000 & 6010
© 2009 Cemtek Environmental, Inc.
CEMTEK Instruments Model 6000 & 6010
Individual Boiler Performance
© 2009 Cemtek Environmental, Inc.
CEMTEK Instruments Model 6000 & 6010
LED - Green / Red Diode Laser
Single Pass Double Pass
No Moving Parts
© 2009 Cemtek Environmental, Inc.
Insitu Duct/ Stack Mount Analyzer
SCR NOX-O2 Monitor
CEMTEK Instruments Model 8000
© 2009 Cemtek Environmental, Inc.
EXSITU CHEMILUMINESCENCE & ZIRCONIA MEASUREMENT High Temperature OperationMinimal Zero DriftFast Response for Feed Forward ControlLow Maintenance (Low Flow Sample System)High Accuracy at Low Detection LevelsAmmonia Scrubber for Post SCR Applications
CEMTEK Instruments Model 8000